Home
WHAT MOVES YOUR WORLD User Manual Mounting
Contents
1. Valve phasing A positive signal D E for 6 PE connector or 4 5 for 11 PE connector causes valve opening P gt A Connector wiring See wiring schematic tag attached to elec tronics housing or refer to the catalog or the installation draw ing Connection Signal lines shielded shielding connected at both ends and additionally connected to reference potential 0 V at the control side to improve EMC Connect the protec tive conductor Observe technical note TN 353 6 Hydraulic System Start Up Pay attention to the pressure setting the venting instructions and the alarm messages 7 Venting only for D638 9 WARNING Hydraulic fluid squirting out Hydraulic fluid squirting out under high pressure or parts falling off can cause serious personal injuries burns and fires Only vent the valve and the actuator at a low sys tem pressure of max 10 bar 145 psi gt Carefully open the venting screw by approx one revolution A 3 Null Adjustment The null adjustment of the valve and further parameterizations can be done via the field bus 9 Service Replacing O rings The mounting surface O rings may be re placed by the customer Pay attention to cleanliness of the valve and of the surroundings Transportation storage Before transportation seal the base of the valve using a clean shipping plate or adhesive tape Seal the connector using a dust protection cap Pack the valve carefully so that it is not damage
2. info luxembourg moog com The Netherlands 31 252 462 000 info thenetherlands moog com Norway 47 6494 1948 info norway moog com Russia 7 831 713 1811 info russia moog com MOO C GLOBAL SUPPORT Singapore 65 677 36238 info singapore moog com South Africa 27 12 653 6768 info southafrica moog com Spain 34 902 133 240 info spain moog com Sweden 46 31 680 060 info sweden moog com Switzerland 41 71 394 5010 info switzerland moog com Turkey 90 216 663 6020 info turkey moog com United Kingdom 44 0 1684 858000 info uk moog com USA 1 716 652 2000 info usa moog com Moog is a registered trademark of Moog Inc and its subsidiaries All trademarks as indicated herein are the property of Moog Inc and its subsidiaries 2015 Moog Inc All rights reserved All changes are reserved WHAT MOVES YOUR WORLD MOOG
3. teklasse 10 9 gem EN ISO 4762 diagonal wechselnd anziehen kant Lochbild Baureihe Schraube gem ISO 4401 03 03 0 05 4 4 4 Innensechs 4 Betriebsdruck Max zulassiger Betriebsdruck pp Siehe Typenschild Seite 2 3 5 Elektrischer Anschluss Elektrische Sicherheit Der Schutzleiteranschluss ist mit dem Elektronikgehause oder Ventilkorper verbunden Die verwen deten Isolierungen sind fur den Schutzkleinspannungsbereich ausgelegt Die Stromkreise der Feldbusanschlusse sind nur funktional galvanisch von anderen angeschlossenen Strom kreisen getrennt Die Einhaltung der Sicherheitsvorschriften erfordert eine Iso lierung vom Netz gem EN 61558 1 und EN 61558 2 6 und eine Begrenzung aller Spannungen gem EN 60204 1 Wir empfehlen die Verwendung von SELV PELV Netzteilen Nennsignal Siehe Typenschild Externe Sicherung je Ventil 2 0 A tr ge bei D636 8 bzw 3 15 A tr ge bei D637 9 Wirkrichtung Bei positivem Signal D E f r 6 PE Stecker oder bei positivem Signal 4 5 f r 11 PE Stecker ergibt sich Ventil ffnung P gt A Steckerbelegung Siehe Anschlussplan am Elektronikge h use im Katalog oder auf der Einbauzeichnung Anschluss Signalleitungen geschirmt Schirm beidseitig auf legen und zus tzlich steuerungsseitig mit Bezugspotenzial 0 V verbinden wegen EMV Schutzleiter anschlie en Technische Notiz TN 353 beachten 6 Hydraulikanlage in Betrieb setzen Druckwerteinstellung Entl
4. Compare model number and type with that specified on hy draulic schematic The valve can be mounted in any position fixed or movable The venting screw has to point upwards only for D638 9 Mounting surface Check for flatness lt 0 01 mm 0 00004 in over 100 mm 3 94 in and finish Ra lt 0 8 um Care must be taken to ensure that contamina tion does not enter the hydraulic system all work areas must be clean of surface or air borne contamination Mounting Socket head screws grade 10 9 according to EN ISO 4762 torque diagonally alternating Pattern to ISO 4401 Socket head screw 03 03 0 05 M5 x 55 D636 8 03 0 D637 9 P 05 05 0 05 M6 x 40 D637 9 R 05 05 0 05 M6 x 60 4 Operating Pressure Maximum operating pressure pp See nameplate 5 Electrical Connection Electrical safety The protective conductor connection is con nected to the electronics housing or valve body The insulation materials employed are designed for use in the safety extra low voltage range The field bus circuit connections are only functionally galvanically isolated from the other connected cir cuits To comply with safety regulations requires isolation from the mains according to EN 61558 1 and EN 61558 2 6 and limiting all voltages according to EN 60204 1 We recommend using SELV PELV power supplies Rated signal See nameplate External fuse per valve 2 0A time lag for D636 8 and 3 15 A time lag for D637 9 Page 2 2
5. Falsche Handhabung Falsche Handhabung von Ventil Werkzeug oder Zu beh r kann Todesf lle schwerste K rperverletzung und erheblichen Sachschaden verursachen gt Arbeiten mit und an Ventilen d rfen ausschlie lich von hierf r qualifizierten und autorisierten Anwen dern durchgef hrt werden Bei Arbeiten mit und an Ventilen Maschinenan lage Hinweise und Vorschriften des Herstellers der Maschinenanlage beachten A MOOG A VORSICHT Zweckentfremdung der Stecker Steckverbinder und Anschlussleitungen Zweckentfremdung wie z B Verwendung als Tritt hilfe oder Transporthalterung kann zur Beschadi gung f hren und somit K rperverletzung sowie wei tere Sachsch den verursachen gt Stecker Steckverbinder und Anschlussleitungen ausschlie lich zum Anschluss des Ventils ver wenden Arbeitsschutz A A A VORSICHT Herabfallende Gegenst nde Herabfallende Gegenst nde wie z B Ventile Werk zeug oder Zubeh r k nnen K rperverletzung und Sachschaden verursachen Geeignete Arbeitsschutzausr stung wie z B Si cherheitsschuhe oder helm tragen A VORSICHT Hei e Oberfl chen an Ventilen und Hydrauliklei tungen Ventile und Hydraulikleitungen k nnen w hrend des Betriebs sehr hei werden Ber hren kann Verbren nungen verursachen Geeignete Arbeitsschutzausr stung wie z B Ar beitshandschuhe tragen A VORSICHT Ger uschentwicklung Der Betrieb der Ventile kann appli
6. Generaci n de ruido El funcionamiento de v lvulas en algunas aplicacio nes puede producir un nivel de ruido muy elevado que puede causar da os al o do gt Usar equipo protector adecuado por ejemplo pro tecci n auditiva ATENCI N Contacto de la piel con liquido hidr ulico Contacto de la piel con liquido hidr ulico puede cau sar heridas gt Respete los avisos de seguiridad para el liquido hidr ulico en uso Vestir equipo protector adecuado como guantes 2 Fluido hidr ulico Aceite hidr ulico de origen mineral seg n la norma DIN 51524 partes 1 a 3 ISO 11158 Otros l quidos hidr ulicos bajo pedido Viscosidad 5 400 mm s recomendado 15 100 mm s Rango de temperaturas Ambiente Ta 20 60 C fluido Tp 20 80 C C digo de limpieza para el aceite hidr ulico Seg n ISO 4406 1999 utilizar como m nimo un aceite de c digo 18 15 12 para mayor duraci n utilizar c digo 17 14 11 La limpieza del fluido hidr ulico influye considerablemente en la seguridad de funcionamiento los desgastes y las roturas Para evitar malfuncionamiento y aumento de problemas reco mendamos una filtraci n adecuada del fluido Instrucciones de limpieza Uso de placas o v lvulas de la vado acuerdo a las indicaciones del fabricante de la m quina P gina 1 3 3 Montaje AVISO Da os debidos a la suciedad a la humedad a los efectos del ozono y a los rayos UV e El almacenamiento en el exterior o
7. commandes pouvant causer des damages auditifs gt Porter l quipement de s curit ad quate comme par exemple des protections auditives ATTENTION Contact du fluide hydraulique avec la peau DA Le contact du fluide hydraulique avec la peau peut causer des blessures corporelles gt Respecter les consignes de s curit applicables au fluide hydraulique utilis gt Porter l quipement de s curit ad quate comme par exemple des gants 2 Fluide hydraulique Huile hydraulique min rale suivant DIN 51524 parties 1 3 ISO 11158 Autres fluides hydrauliques sur demande Viscosit 5 400 mm s recommend 15 100 mm s Plage de temperature Ambiance T 20 60 C fluide Tp 20 80 C Classe de propret Suivant ISO 4406 1999 inf rieure a 18 15 12 pour une dur e de vie lev e une classe de 17 14 11 est recommand e La propret du fluide hydraulique est essentielle pour garantir un fonctionnement correct et une dur e de vie lev e Afin d viter tout disfonctionnement et augmenter la dur e de vie nous recommandons de r aliser une filtration du circuit hy draulique ad quate Rincage Avant montage de la valve le circuit hydraulique doit tre rinc selon les instructions du fabricant de la ma chine Remplacer la valve par une plaque de rincage ou une valve de rincage Page 1 2 3 Installation AVIS Dommages dus a la salet a l humidit et aux effets de l ozone UV e L
8. del cero El ajuste del cero de la v lvula as como otras parametrizacio nes se pueden llevar a cabo en el bus de campo fieldbus 9 Servicio Cambio de las juntas t ricas Las juntas t ricas de las su perficies de montaje pueden ser cambiadas por el cliente Al hacerlo es imprescindible que la v lvula y el entorno de mon taje est n limpios Transporte almacenamiento Antes del transporte selle la base de la v lvula con una placa de protecci n limpia o con cinta adhesiva Selle el conector con un tap n de protecci n para el polvo Empaquete la v lvula con cuidado para que no resulte da ada durante el transporte o el almacenamiento Inspecci n Tras un periodo de 5 a os de almacenamiento o en ausencia de funcionamiento recomendamos que se ins peccione la v lvula en un centro de servicio autorizado para evitar posibles da os Reparaciones Reparaciones solo deben ser realizadas por Moog por nuestras asistencias t cnicas autorizadas La entrega de v lvulas reparadas o reemplazadas se rea liza como en el caso de v lvulas nuevas con par metros de f brica Por ello se debe comprobar que las v lvulas ten gan la configuraci n y los par metros correctos antes de po ner en servicio nuevamente En caso necesario el usuario debe restituir la configuraci n y los par metros originales pro porcionados por el fabricante de la m quina Instrucciones de montaje y puesta en marcha D636 7 8 9 B97072 636 005 Ver
9. Usare spine collegamenti di spine e condutture di giunzione esclusivamente per l allacciamento della valvola Protezione durante il lavoro A ATTENZIONE Caduta di oggetto La caduta di oggetti come p es valvole utensili o at trezzature pu causare lesioni corporee e danni ma teriali Indossare adeguate attrezzature di lavoro protet tive come p es scarpe antinfortunistiche e casco protettivo ATTENZIONE Superfici roventi su valvole e condutture idrauli che Durante il funzionamento le valvole e le condutture idrauliche possono diventare estremamente calde contatto con essi pu causare bruciature Indossare adeguato abbigliamento di lavoro pro tettivo come p es guanti protettivo ATTENZIONE Emissione di rumori Il funzionamento delle valvole pu causare un note vole emissione rumorosa a causa delle specifiche applicazioni questi rumori possono portare a danni dell udito gt Portare adeguate D P l Dispositivi protezione individuale p es cuffie per la protezione dell udito ATTENZIONE Contatto con la pelle del fluido idraulico Il fluido idraulico a contatto con la pelle pu causare lesioni cutanee gt Rispettare le prescrizioni di sicurezza per il fluido idraulico impiegato Indossare adeguato abbigliamento di lavoro pro tettivo come p es guanti protettivo Pagina 1 3 2 Fluido idraulico Fluido idraulico a base di olio minerale secondo DIN 51524 parti
10. User Manual Mounting and Installation Notes D636 7 8 9 Series Servo Valves Benutzerinformation Montage und Inbetriebnahme Hinweise Baureihen D636 7 8 9 Servoventile Manuel de l utilisateur Instructions de mise en service Series D636 7 8 9 Servovalves Manuale dell utilizzatore Istruzioni di montaggio ed installazione Serie D636 7 8 9 Servovalvole Manual del usuario Instrucciones de montaje y puesta en marcha Series D636 7 8 9 Servov lvulas B97072 636 Rev G February 2015 WHAT MOVES YOUR WORLD MOOC User Manual Mounting and Installation Notes D636 7 8 9 Series Servo Valves 1 Safety Handling the valves machines WARNING Carrying out work on the valves machine during A operation Carrying out any work during operation such as e g hydraulic connection of components can cause un controlled sequences of motions malfunction and others and thus may result in fatalities serious per sonal injuries and serious damage to property gt During operation do not carry out any work on the valves machine Before working on the valves machine stop the machine and switch off the supply voltage gt Secure the machine against restarting Examples of suitable securing measures Lock the main command device and remove the key Attach a warning sign to the master switch WARNING Hydraulic fluid squirting out Hydraulic fluid squirting out under high pressure or parts fall
11. a utilizar con los tapones de protecci n sin el conector de acoplamiento Comparar el n de modelo y el tipo con los datos del esquema de conexiones hidr ulicas La v lvula puede ser montada en cualquier posici n fijo 6 movible El tornillo de purgar el aire debe quedar siempre mirando hacia arriba solo D638 9 Superficie de montaje Comprobar la planidad lt 0 01 mm en 100mm y la profundidad de las rugosidades Ra lt 0 8 um Al colocar la v lvula tener en cuenta que tanto sta como el entorno de montaje est n limpios Fijaci n Tornillos de cabeza hexagonal interior calidad 10 9 seg n norma EN ISO 4762 atornillar alternando diagonal mente Par de apriete Tornillo de cabeza hexa gonal interior Asiento seg n ISO 4401 D636 8 03 03 0 05 M5 x 55 D637 9 P 05 05 0 05 M6 x 40 D637 9 R 05 05 0 05 M6 x 60 4 4 Presi n de trabajo Presi n max de trabajo admitida pp V ase placa de carac ter sticas 5 Conexi n el ctrica Seguridad el ctrica La toma del cable de protecci n a tierra va unido a la carcasa electr nica o bien al cuerpo de v lvula El aislamiento utilizado ha sido dimensionado para el rango de tensiones peque as de protecci n Los circuitos de corriente de las conexiones de bus de campo van separados solamente de modo funcional galv nicamente del resto de los circuitos de corriente conectados P gina 2 3 El cumplimiento de las normativas de seguridad exige un ais la
12. cita di liquido idraulico La fuoriuscita a forte getto di liquido idraulico e pezzi che si staccano possono causare gravi lesioni corpo ree bruciature e incendi Depressurizzare condutture idrauliche e serbatoi idraulici prima di effettuare lavori su valvole im pianto meccanico Durante il montaggio delle valvole osservare le specifiche delle viti di fissaggio e della superficie di montaggio nonch accertarsi della presenza dell elasticit integrit e della sede corretta degli O ring Rispettare la massima pressione di lavoro Fare attenzione ai segnali come leggere perdite d olio o eventuali trasudazioni che possono indi care un errore di assemblaggio e o un guasto del componente Vv vw AVVERTENZA Scorretta manipolazione Una scorretta manipolazione di valvole utensili o at trezzature pu causare decessi gravissime lesioni corporee e notevoli danni materiale gt Lavori con e su valvole possono essere eseguiti esclusivamente da utilizzatori specificamente qualificati ed autorizzati gt Durante i lavori con e su valvole impianto mecca nico osservare le indicazioni e le prescrizioni del produttore dell impianto meccanico A MOOG A ATTENZIONE Uso improprio delle spine dei collegamenti di spine e di condutture di giunzione Un uso improprio come p es appoggio per il piede o come aggancio per il trasporto pu causare danni e di conseguenza lesioni corporee ed ulteriori danni materiali gt
13. d during transportation or stor age Inspection Following a period of storage or no operation for more than 5 years we recommend that the valve is inspected by an authorized service center in order to prevent possible damage Repairs Repairs may only be carried out by us or by our au thorized service centers Repaired valves or replacement valves are delivered like new valves with factory settings Therefore the valves have to be checked for correct configuration and changed parame terization before re initiation If necessary the user has to re store the machine manufacturer s original configuration and parameterization 10 Disposal It is essential to comply with the relevant national waste dis posal regulations and environmental protection provisions when disposing of valves spare parts or accessories packag ing that is no longer needed hydraulic fluid or auxiliary materi als and substances used for cleaning Mounting and Installation Notes D636 7 8 9 B97072 636 001 Version G 02 15 2003 2006 2008 2009 2010 Moog GmbH All rights reserved Subject to changes Hanns Klemm Str 28 71034 B blingen GERMANY www moog com industrial Benutzerinformation Montage und Inbetriebnahme Hinweise Baureihen D636 7 8 9 Servoventile 1 Sicherheit Umgang mit Ventilen Maschinenanlagen A Montage und Inbetriebnahme Hinweise D636 7 8 9 B97072 636 002 Version G 02 15 WARNUNG Arbeiten a
14. da 1 a 3 ISO 11158 Altri fluidi idraulici a richiesta Viscosit 5 400 mm s raccomandato 15 100 mm s Campo di variazione della temperatura Ambiente Ta 20 60 C fluido Tp 20 80 C Classe di pulizia Secondo ISO 4406 1999 al minimo classe 18 15 12 per una pulizia standard per una pulizia migliore ri spettare le classi 17 14 11 La pulizia del fluido idraulico incide sulla sicurezza di funziona mento e sull usura Per evitare malfunzionamenti e usure rac comandiamo di filtrare il fluido idraulico conformemente Istruzioni di flussaggio Usare piastre di flussaggio valvole di flussaggio in base alle istruzioni della casa costruttrice della macchina 3 Installazione AVVISO Danni dovuti agli effetti dello sporco dell umidit e dell ozono UV Lo stoccaggio all aperto o in condizioni climatiche errate pu causare la corrosione o altri danni alla valvola La con densa dovuta alle variazioni di temperatura pu provocare malfunzionamenti elettrici In caso di stoccaggio temporaneo rispettare le seguenti condizioni di immagazzinamento Temperatura ambiente raccomandata da 15 a 25 C temperatura ammissibile da 40 a 80 C variazione di temperatura lt 10 C e Umidit relativa lt 65 senza condensa Assicurarsi che nell ambiente di stoccaggio delle val vole le vibrazioni e gli urti siano minimi In seguito al trasporto o allo stoccaggio delle valvole at tendere che abbiano ragg
15. en condiciones clim ti cas desfavorables puede causar corrosi n y otros da os a la v lvula La condensaci n causada por las fluctuaciones de la temperatura pueden causar fallos en el funciona miento de la electr nica En caso de almacenamiento cumpla las siguientes condiciones de almacenamiento Temperatura ambiente recomendada de 15 a 25 C temperatura admisible de 40 a 80 C fluc tuaci n de temperatura lt 10 C Humedad relativa lt 65 sin condensaci n Aseg rese de que las variaciones de temperatura y humedad en el lugar en que se almacenan las v lvu las son m nimas Despu s del transporte o el almacenamiento de las val vulas espere hasta que hayan alcanzado la tempera tura ambiente antes de ponerlas en marcha e La suciedad y la humedad pueden penetrar en la v lvula a trav s de las aberturas u orificios y causar da os Las jun tas pueden resultar da adas a causa de los efectos del ozono y la radiaci n UV Durante el almacenamiento y el transporte selle los co nectores con los tapones de protecci n para el polvo y coloque la placa de protecci n para el transporte en la superficie de montaje gt No retire los tapones de protecci n para el polvo y la placa de protecci n para el transporte hasta inmediata mente antes de montar las v lvulas y guarde el material de embalaje para un futuro almacenamiento y trans porte Selle cualquier conector de v lvula que no se vaya
16. ente dal noi o da nostri concessionari autorizzati Istruzioni di montaggio ed installazione D636 7 8 9 B97072 636 004 Versione G 02 15 2003 2006 2008 2009 2010 Moog GmbH Salvo ogni diritto Riservandosi Cambiamenti Hanns Klemm Str 28 71034 B blingen GERMANY www moog com industrial Le valvole riparate o sostituite vengono rese come fos sero nuove con le tarature di fabbrica Prima di mettere in funzione le valvole bisogna controllare la loro corretta configu razione ed eventuali cambiamenti dei parametri L utente deve eventualmente ripristinare la configurazione ed i parametri ori ginari dell azienda produttrice dei macchinari ed impianti 10 Smaltimento Per lo smaltimento delle valvole parti di ricambio o accessori materiali d imballo non pi utilizzati liquidi idraulici oppure de tergenti o altre sostanze utilizzate per la pulizia devono essere rispettate le locali leggi per lo smaltimenti e le locali disposi zioni per la protezione dell ambiente Istruzioni di montaggio ed installazione D636 7 8 9 B97072 636 004 Versione G 02 15 Pagina 3 3 Manual del usuario MOOC Instrucciones de montaje y puesta en marcha Series D636 7 8 9 Servov lvulas 1 Seguridad Trato de v lvulas instalaciones ADVERTENCIA Labores sobre v lvulas instalaciones durante funcionamento Todo tipo de labores durante el funcionamento por ejemplo conexi n de componentes pueden causar movimientos no co
17. entreposage de la servovalve l ext rieur ou dans des conditions climatiques d favorables peut provoquer de la corrosion ou d autres dommages La condensation due a des variations de temp rature peut entra ner des dysfonc tionnements lectroniques En cas d entreposage temporaire respectez les condi tions de stockage suivantes Temp ratures ambiantes recommand es 15 25 C temp rature autoris e 40 80 C varia tion de temp rature lt 10 C Humidit relative lt 65 sans condensation e Veillez a ce que le lieu de stockage des servovalves soit soumis un niveau minimum de choc et de vibra tion gt Apr s le transport ou le stockage attendez que les ser vovalves aient atteint la temp rature ambiante avant de les mettre en service e La salet et l humidit peuvent p n trer dans la servovalve travers les ouvertures et l endommager Les joints peu vent tre endommag s par les effets de l ozone et des UV Pendant le stockage et le transport scellez les connec teurs l aide de capuchons de protection anti poussi re et installez la plaque de transport sur la surface de mon tage gt Enlevez les capuchons de protection anti poussi re et la plaque de transport juste avant de monter les valves et conservez les emballages des fins de stockage et de transport ult rieurs gt Scellez l aide de capuchons de protection tous les connecteurs de la valve qui ne sont pas uti
18. error de montaje y o fallo de un componente v Vv A ADVERTENCIA Trato no apropriado A El trato no apropriado de las valvulas las herramine tas 0 los accesorios puede causar muerte lesiones graves y danos materiales considerables gt Obras sobre y con v lvulas han de llevarse a cabo por parte de usuarios debidamente instrui dos y autorizados Atengase siempre las instruciones y los avisos del fabricante de la maquina durante todo tipo de trabajo sobre las valvulas Instrucciones de montaje y puesta en marcha D636 7 8 9 B97072 636 005 Version G 02 15 A ATENCION Mal uso de conectores y tuberias de toma A Cualquier tipo de mal uso por ejemplo utilizarlos como escalon asa 0 otro tipo de apoyo de transporte puede causar lesiones graves y da os materiales considerables gt Usen conectores y tuber as de toma solo para co nectar con la v lvula Seguridad en el trabajo ATENCI N Objetos que se caen Objetos que se caen como v lvulas herramientas 6 accesorios pueden causar lesiones graves y da os materiales considerables Vestir equipo protector adecuado como zapatos de seguridad 6 cascos ATENCI N Superficies muy calientes en v lvulas y tuber as A hidr ulicas Las v lvulas y las tuberias hidr ulicas pueden alcan zar temperaturas muy elevadas durante el funciona miento Tocarlas puede causar quemaduras Vestir equipo protector adecuado como guantes ATENCI N
19. ftungsvorschrift und St rmeldun gen beachten 7 Entl ften nur bei D633 9 A WARNUNG Herausspritzende Hydraulikfl ssigkeit Unter hohem Druck herausspritzende Hydraulikfl s sigkeit oder abspringende Teile k nnen zu schweren K rperverletzungen Verbrennungen und Br nden f hren Ventil und Verbraucher nur bei niedrigem Sys temdruck von maximal 10 bar entl ften Entl ftungsschraube vorsichtig ca eine Umdre hung ffnen 3 Nulleinstellung Die Nulleinstellung des Ventils sowie weitere Parametrierun gen k nnen ber den Feldbus vorgenommen werden 9 Service Tausch der O Ringe Die O Ringe der Montagefl chen d r fen vom Kunden getauscht werden Dabei ist auf Sauberkeit des Ventils und der Umgebung zu achten Transport Lagerung Vor dem Transport eines Ventils die Ventilgrundfl che mit einer sauberen Staubschutzplatte oder Klebeband abdichten Die Anbaustecker mit einer Staub schutzkappe abdichten Ventil sorgf ltig verpacken damit es w hrend des Transports oder der Lagerung zu keinen Besch digungen kommt Inspektion Nach einer Lagerdauer oder dem Betrieb von mehr als 5 Jahren empfehlen wir das Ventil von uns oder ei nem unserer autorisierten Servicestellen zu berpr fen um m gliche Folgesch den oder Besch digungen zu vermeiden Reparaturen Reparaturen d rfen nur von uns oder unseren autorisierten Servicestellen durchgef hrt werden Die Auslieferung von reparierten Ventilen bzw Aus
20. ing off can cause serious personal injuries burns and fires Before working on the valves machine depres surize all hydraulic lines and accumulators When mounting the valves observe the specifica tion of the installation screws and the mounting pattern and ensure the presence elasticity integ rity and correct seating of the O rings Observe the maximum operating pressure Please pay attention for signs such as a slight oil leak or sweating which may indicate an assem bly error and or component failure WARNING Wrong handling Wrong handling of the valve tools or accessories may result in fatalities serious personal injuries and serious damage to property gt Only properly qualified and authorized users may work with and on the valves gt When working with and on the valves machine observe the machine manufacturer s notes and in structions CAUTION Misuse of the connectors mating connectors plugs and connection cables Misuse such as e g use as foot hold or transport fix ture can cause damage and thus may result in per sonal injuries as well as further damage to property Use the connectors mating connectors and con nection cables exclusively for the connection of the valve Mounting and Installation Notes D636 7 8 9 B97072 636 001 Version G 02 15 MOOG Occupational safety and health A CAUTION Falling objects Falling objects such as e g valves too
21. iunto la temperatura ambiente prima di metterle in servizio Sporco e umidit possono infiltrarsi nella valvola attraverso le aperture e danneggiarle Le guarnizioni potrebbero dan neggiarsi a causa degli effetti dell ozono e dei raggi ultra violetti Durante lo stoccaggio e il trasporto chiudere i connet tori con le protezioni antipolvere e installare la piastra di protezione sulla superficie di montaggio gt Rimuovere le protezioni antipolvere e la piastra di prote zione solo immediatamente prima del montaggio delle valvole e conservare i materiali di imballaggio per lo stoccaggio e il trasporto futuri Chiudere con le protezioni antipolvere tutti i connettori della valvola che non sono utilizzati durante il funziona mento senza connettore di accoppiamento Comparare il numero di modello e il tipo con riferimento allo schema idraulico La valvola pu essere montata fissa o mo bile con un qualsiasi orientamento La vite di sfiato aria deve essere rivolta verso l alto soltanto D638 9 Superficie di montaggio Testare la superficie di montaggio riguardo alla planarita lt 0 01 mm su 100 mm e rugosit Ra lt 0 8 um Attenzione alla pulizia della valvola e dell am biente al momento dell installazione della stessa Montaggio Viti con esagono incassato grado di resistenza 10 9 secondo EN ISO 4762 Serrare incrociando na Attacchi D636 8 secondo D636 8 ISO 4401 D63710 P Viti con esagono i
22. kationsspezifisch erhebliche Ger uschentwicklung verursachen die zu Geh rsch den f hren kann gt Geeignete Arbeitsschutzausr stung wie z B Ge h rschutz tragen A VORSICHT Hautkontakt mit Hydraulikfl ssigkeit Hautkontakt mit Hydraulikfl ssigkeit kann K rperver letzung verursachen Sicherheitsbestimmungen f r die eingesetzte Hy draulikfl ssigkeit beachten Geeignete Arbeitsschutzausr stung wie z B Ar beitshandschuhe tragen Seite 1 3 2 Hydraulikflussigkeit Hydraulik l auf Mineral lbasis gem DIN 51524 Teil 1 bis 3 ISO 11158 Andere Hydraulikfl ssigkeiten auf Anfrage Viskosit t 5 400 mm s empfohlen 15 100 mm s Temperaturbereich Umgebung Ty 20 60 C Fl ssigkeit Tr 20 80 C Sauberkeitsklasse Gem ISO 4406 1999 mindestens Klasse 18 15 12 f r erh hte Standzeit Klasse 17 14 11 Die Sauberkeit der Hydraulikfl ssigkeit hat gro en Einfluss auf Funktionssicherheit und Verschlei Um St rungen und erh h ten Verschlei zu vermeiden empfehlen wir die Hydraulikfl s sigkeit entsprechend zu filtern Sp lanweisung Verwendung von Sp lplatten oder Sp lventi len gem den Vorschriften des Herstellers der Maschinenan lage 3 Einbau HINWEIS Besch digung durch Schmutz Feuchtigkeit und Ozon UV Einwirkung Lagerung im Freien oder unter falschen klimatischen Be dingungen kann zu Korrosion f hren und das Ventil besch digen Kondensation durch Temperatur
23. l sistema idraulico Fare attenzione alla taratura della pressione alle istruzioni di spurgo dell aria ed ai messaggi di allarme 7 Degasaggio soltanto D638 9 A AVVERTENZA Fuoriuscita di liquido idraulico La fuoriuscita a forte getto di liquido idraulico e pezzi che si staccano possono causare gravi lesioni corpo ree bruciature e incendi Degasare la valvola e l utilizzatore solo a bassa pressione nel sistema max 10 bar gt Svitare attentamente la vite di degasaggio di ca un giro 8 Regolazione dello zero L azzeramento della valvola nonch i parametri della stessa possono essere effettuati mediante il collegamento field bus 9 Manutenzione Cambio delle guarnizioni O ring Gli O ring sulle superfici di montaggio possono essere sostituiti dal cliente Prestare at tenzione alla pulizia della valvola e dell area circostante Trasporto stoccaggio Prima di effettuare il trasporto sigil lare la base della valvola utilizzando una piastra di trasporto pulita o del nastro adesivo Sigillare il connettore utilizzando una protezione antipolvere Imballare accuratamente la val vola affinch non venga danneggiata durante il trasporto o lo stoccaggio Controllo Se la valvola resta in magazzino o non viene utiliz zata per un periodo superiore a 5 anni opportuno farla con trollare presso un centro di assistenza autorizzato per preve nire possibili danni Riparazioni Riparazioni possono essere eseguita solam
24. lis s sans connecteur mont V rifier que le num ro de mod le et le type correspondent ceux d finis par le sch ma hydraulique La valve peut tre mont e dans n importe quelle position fixe ou mobile La vis d vent doit d boucher vers le haut seulement D638 9 Surface de montage Verifier la planeite de la surface de montage lt 0 01 mm sur 100 mm et son tat de surface Ra lt 0 8 um Nettoyer soigneusement la valve et l environne ment avant l installation Montage Utiliser des vis de fixation classe 10 9 suivant EN ISO 4762 Serrer alternativement dans des directions dia suivant gonales Vis de Couple ISO 4401 fixation Nm pesse 0303005 woxss 4 68_ 3 Plan de pose D636 8 D637 9 P 05 05 0 05 M6 x 40 D637 9 R 05 05 0 05 M6 x 60 4 Pression de service Pression de service maximale pP Se r f rer la plaque si gnal tique 5 Raccordement lectrique S curit lectrique Le raccord du conducteur de protection est reli l lectronique ou au corps de la valve Les isolations utilis es sont con ues pour la gamme des tr s basses ten sions de s curit Les circuits lectriques des raccords de bus de terrain sont seulement isol s galvaniquement des autres circuits lectriques raccord s Le respect des consignes de s curit exige une isolation du secteur selon EN 61558 1 et EN 61558 2 6 et une limitation de toutes les tensions selon EN 60204 1 Nous recomman dons l
25. ls or acces sories may result in personal injuries and damage to property gt Wear suitable safety equipment such as e g safety shoes or helmet A CAUTION Hot surfaces of valves and hydraulic lines Valves and hydraulic lines can become very hot dur ing operation Contact may result in burns gt Wear suitable safety equipment such as e g work gloves A CAUTION Noise emission A Depending on the application significant levels of noise can be generated when the valves are oper ated This may result in hearing damage gt Wear suitable safety equipment such as e g ear protection A CAUTION Skin contact with hydraulic fluid Skin contact with hydraulic fluid may result in per sonal injuries Observe the safety regulations applicable to the hydraulic fluid used gt Wear suitable safety equipment such as e g work gloves 2 Hydraulic Fluid Mineral oil based hydraulic fluid according to DIN 51524 parts 1 to 3 ISO 11158 Other hydraulic fluids on request Viscosity 5 400 mm s recommended 15 100 mm s Temperature range Ambient T 20 60 C 68 140 F fluid Tp 20 80 C 68 178 F Class of cleanliness According to ISO 4406 1999 at least class 18 15 12 for longer life class 17 14 11 recommended The cleanliness of the hydraulic fluid greatly influences the functional safety and the wear and tear In order to avoid mal functions and increased wear and tear we recommend filtra
26. miento de la red conforme a la EN 61558 1 y EN 61558 2 6 as como una limitaci n de todas las tensiones conforme a la EN 60204 1 Recomendamos el uso de fuentes de alimenta ci n de SELV PELV Se al nominal V ase placa de caracter sticas El fusible externo de la v lvula 2 0 A lento para D636 8 y 3 15 A lento para D637 9 Sentido del flujo Una se al positiva D E en conectores 6 PE o 4 5 en conectores 11 PE abre la v lvula de P gt A Asignaci n de pins en los conectores V ase diagrama de conexi n en la carcasa electr nica en el cat logo o en el plano de montaje Conexi n L neas de se al apantalladas con pantalla conec tada en ambos extremos y adicionalmente conectada al cero de referencia de potencial 0 V en el lado del control para me jorar EMC Conectar el conductor de protecci n Seguir la nota t cnica TN 353 6 Puesta en funcionamiento el sistema hidr ulico Tener en cuenta el ajuste de los valores de presi n instruccio nes de purgado e indicaciones de fallos 7 Purgar el aire solo D638 9 A ADVERTENCIA Salpicaduras de l quido hidr ulico Las salpicaduras de l quido hidr ulico o piezas des prendidas que se producen bajo alta presi n pueden causar lesiones graves quemaduras o incendios gt Solamente purgar el aire si hay presi n baja en el s stema hidr ulico como m ximo 10 bar gt Abrir cuidadosamente el tornillo de purgar el aire girando solamente una vuelta 3 Ajuste
27. n Ventilen Maschinenanlage w hrend des Betriebs Arbeiten wahrend des Betriebs wie z B hydrauli scher Anschluss von Komponenten k nnen unkon trollierte Bewegungsabl ufe Fehlfunktionen u a verursachen und somit zu Todesf llen schwerster K rperverletzung und erheblichem Sachschaden f hren W hrend des Betriebs keinerlei Arbeiten an Venti len Maschinenanlage durchf hren gt Vor Arbeiten an Ventilen Maschinenanlage ge samte Anlage stillsetzen und Versorgungsspan nung abschalten gt Maschinenanlage gegen Wiedereinschalten si chern Beispiele f r geeignete Sicherungsmak nahmen Hauptbefehlseinrichtung Schl ssel abziehen e Warnschild am Hauptschalter anbringen verschlie en und WARNUNG Herausspritzende Hydraulikfl ssigkeit Unter hohem Druck herausspritzende Hydraulikfl s sigkeit oder abspringende Teile k nnen zu schweren K rperverletzungen Verbrennungen und Br nden f hren gt Vor Arbeiten an Ventilen Maschinenanlage Hy draulikleitungen und Hydraulikspeicher drucklos machen Bei der Montage von Ventilen Spezifikation von Befestigungsschrauben und Montagefl che be achten sowie Vorhandensein Elastizit t Unver sehrtheit und korrekten Sitz der O Ringe sicher stellen Maximalen Betriebsdruck beachten Auf Indikatoren f r eine fehlerhafte Montage oder ein eventuelles Bauteilversagen achten wie z B leichter Olaustritt am Ventil Schwitzen v v WARNUNG
28. ncassato Copia di serraggio Pagina 2 3 4 Pressione operativa Pressione massima di esercizio pp Vedere la targhetta 5 Connessione elettrica Sicurezza elettrica ll collegamento a terra connesso con l elettronica o con il corpo della valvola Gli isolamenti impie gati sono destinati alla protezione per bassa tensione circuiti elettrici dei collegamenti per bus di campo sono solamente iso lati galvanicamente dagli altri circuiti connessi Il rispetto delle norme di sicurezza richiede l isolamento dalla rete secondo EN 61558 1 e EN 61558 2 6 nonch la limita zione di tutte le tensioni secondo EN 60204 1 Si consiglia l im piego di alimentatori SELV PELV Segnale nominale Vedere la targhetta Fusibile esterno per ciascuna valvola 2 0 A ritardato per D636 8 o 3 15 A ritardato per D637 9 Fasamento della valvola Con segnale positivo D E per connettore 6 PE oppure 4 5 per connettore 11 PE l aper tura della valvola P gt A Cablaggio del connettore Vedere l etichetta dello schema di collegamento attaccata alla custodia dell elettronica oppure far riferimento allo schema di installazione del catalogo Connessione ll cavo deve essere schermato la schermatura va collegata ad entrambe le estremit e inoltre va collegato al potenziale di riferimento 0 V sul lato del controllo per miglio rare la CEM Collegare il terminale di messa a terra Prego attenersi al bollettino tecnico TN 353 6 Avviamento de
29. ntrolados malfuncionamiento causando muerte lesiones graves y da os materia les considerables gt Queda prohibido realizar cualquier tipo de obras en v lvulas instalaciones mientras stas est n en funcionamiento gt Antes de empezar cualquier tipo de obra sobre v lvulas instalaciones hay que parar toda la insta laci n y desconectar la alimentaci n el ctrica La instalaci n debe ser asegurada contra la puesta en marcha accidental Ejemplos de medi das adecuadas Cerrar el mando central y guardar la llave Colocar un aviso sobre el mando central ADVERTENCIA Salpicaduras de l quido hidr ulico A Las salpicaduras de l quido hidr ulico o piezas des prendidas que se producen bajo alta presi n pueden causar lesiones graves quemaduras o incendios gt Antes de iniciar obras en v lvulas deber n ase gurarse de que todas las tuber as hidr ulicas y el acumulador hidr ulico est n libre de presi n Durante el montaje de la v lvula se deber n aca tar las especificaciones t cnicas de los tornillos de fijaci n y de la superficie de montaje Igual mente hay que comprobar que est n presentes las juntas t ricas de los puertos que est n intac tas que su elasticidad sea suficiente y que est n en su posici n correcta gt At ngase a las indicaciones de la presi n maxima del sistema Por favor preste atenci n a se ales como una li gera fuga de aceite o sudor lo que puede indicar un
30. r des malfonc tionnements et des dommages graves sur les per sonnes et sur le mat riel Seules les personnes autoris es et qualifi es peuvent travailler avec sur les commandes Lors de travaux sur les commandes installations suivre les instructions et informations du fabricant de la machine ATTENTION Utilisation d tourn e des connecteurs A L utilisation d tourn e des connecteurs par exemple comme marchepied ou fixation pour le transport peuvent entrainer des dommages mat riels et corpo rels importants Utiliser les connecteurs uniquement pour le bran chement des commandes installations Instructions de mise en service D636 7 8 9 B97072 636 003 Version G 02 15 MOOG Protection du travailleur A ATTENTION Objets tombants A Des objets tombants comme par exemple com mandes outils et accessoires peuvent blesser des personnes ou endommager les biens gt Porter l quipement de s curit adequate comme par exemple des chaussures de s curit ou un casque ATTENTION Surfaces chaudes des commandes et des A conduites hydrauliques Les commandes et conduites hydrauliques peuvent chauffer durant le fonctionnement d ou un risque de br lures en cas de contact gt Porter l quipement de s curit ad quate comme par exemple des gants ATTENTION Emissions sonores Suivant les applications des missions sonores plus ou moins lev es peuvent tre engendr es par les
31. s graves sur les personnes et sur le materiel Pendant le fonctionnement toutes op rations sur les commandes installations sont a proscrire Avant de commencer a travailler sur les com mandes installation arr ter la machine et couper l alimentation lectrique gt L installation doit tre s curis e contre la mise en marche accidentelle Exemple de mesure prendre e Fermer l interrupteur central et enlever la cl e Coller un avis de mise en garde sur l interr upteur central AVERTISSEMENT Fuite de fluide hydraulique Une forte pression peut entra ner des projections de liquide hydraulique ou l expulsion de certaines pi ces Ces ph nom nes peuvent causer de graves blessures corporelles des br lures et des incendies Avant de manipuler les commandes installations s assurer que les accumulateurs et conduites soit d pressuris s Lors du montage des commandes suivre les ins tructions concernant les vis et la surface de mon tage et assurer la pr sence l lasticit l int grit et la position correcte des joints toriques Respecter la pression maximale d op ration Merci de prendre garde aux signes avant cou reurs tels que les fuites l g res ou une transpi ration d huile qui pourrait indiquer une erreur d assemblage ou une d faillance du produit v vw AVERTISSEMENT Manipulation incorrecte Des manipulations incorrectes sur les com mandes installations peuvent entraine
32. schwan kung kann zu internem Kurzschluss f hren Bei einer Zwischenlagerung folgende Lagerbedingun gen beachten Umgebungstemperatur empfohlen 15 bis 25 C zu l ssig 40 bis 80 C Temperaturschwankung lt 10 C Relative Luftfeuchtigkeit lt 65 nicht kondensierend Schwingungs und sto freie Lagerung Mit der Inbetriebnahme nach Transport bzw Lagerung der Ventile so lange warten bis die Ventile die Umge bungstemperatur angenommen haben Schmutz und Feuchtigkeit k nnen in das Ventil durch ff nungen eindringen und das Ventil besch digen Dichtun gen k nnen durch Ozon oder UV Einwirkungen besch digt werden Bei Lagerung und Transport Anbaustecker mit Staub schutzkappe verschlie en und Staubschutzplatte auf die Montagefl che montieren gt Staubschutzkappen und Staubschutzplatte erst kurz vor der Ventilmontage abnehmen und f r Lagerung und Transport aufbewahren Die bei Betrieb nicht verwendeten Ventilstecker ohne eingesteckten Gegenstecker mit Staubschutzkappe verschlie en Modellnummer und Typ mit Angaben im Hydraulikschaltplan vergleichen Das Ventil kann in jeder Lage fest oder beweg lich eingebaut werden Die Entl ftungsschraube muss nach oben zeigen nur bei D638 9 Montagefl che Auf Ebenheit lt 0 01 mm auf 100 mm und Rauhtiefe R lt 0 8 um pr fen Beim Einbau des Ventils auf Sauberkeit des Ventils und der Umgebung achten Befestigung Innensechskant Schrauben G
33. si n G 02 15 Todos los derechos reservados 2003 2006 2008 2009 2010 Moog GmbH Se reserva el derecho a posibles modificaciones Hanns Klemm Str 28 71034 B blingen GERMANY www moog com industrial 10 Eliminaci n de residuos Al eliminar desechos los residuos de v lvulas de accesorios del embalaje superfluo de liquido hidr ulico de los medios de limpieza usados y de substancias de limpieza usadas debe respetar las normas de tratamiento de desechos y las leyes de protecci n ambiental de su pa s Instrucciones de montaje y puesta en marcha D636 7 8 9 B97072 636 005 Versi n G 02 15 P gina 3 3 For more information on Moog Global Support visit www moog com industrial service Argentina 54 11 4326 5916 info argentina moog com Australia 61 3 9561 6044 info australia moog com Brazil 55 11 3572 0400 info brazil moog com Canada 1 716 652 2000 info canada moog com China 86 21 2893 1600 info china moog com Finland 358 10 422 1840 info finland moog com France 33 1 4560 7000 info france moog com Germany 49 7031 622 0 info germany moog com Hong Kong 852 2 635 3200 info hongkong moog com www moog com industrial India 91 80 4057 6666 info india moog com Ireland 353 21 451 9000 info ireland moog com Italy 39 0332 421 111 info italy moog com Japan 81 46 355 3767 info japan moog com Korea 82 31 764 6711 info Korea moog com Luxembourg 352 40 46 401
34. t ing the hydraulic fluid accordingly Flushing instruction Use of flushing plates or flushing valves according to the machine manufacturer s instructions Page 1 2 3 Installation NOTICE Damage due to dirt moisture and ozone UV effects Storage outside or under the wrong climatic conditions can cause corrosion and other damage to the valve Conden sation due to temperature fluctuations can result in elec tronic malfunctions In the case of intermediate storage observe the follow ing storage conditions Recommended ambient temperature 15 to 25 C 60 to 78 F permissible temperature 40 to 80 C 40 to 176 F temperature fluctuation lt 10 C 18 F Relative humidity lt 65 not condensing Ensure there are minimal vibration and shock where valves are stored Following transport or storage wait until the valves have reached ambient temperature before starting up e Dirt and moisture can enter the valve through openings and cause damage Seals can be damaged due to the effects of ozone and UV During storage and transport seal connectors with dust protection caps and install the shipping plate on the mounting surface gt Remove dust protection caps and shipping plate only shortly before mounting the valves and keep packaging materials for future storage and transport gt Seal with protection caps any valve connectors that are not used in operation without mating connector
35. t tre ef fectu s via le bus de terrain 9 Service Remplacement des joints toriques Les joints toriques des surfaces de montage peuvent tre remplac s par le client Il faut assurer une propret impeccable de la valve et de l envi ronnement de travail Transport stockage Avant le transport scellez la base de la valve l aide d une plaque de transport propre ou de ruban ad h sif Scellez le connecteur l aide d un capuchon de protec tion anti poussi re Emballez la valve soigneusement de fa on ne pas l endommager pendant le transport ou le stockage Inspection Apr s une p riode de stockage ou d inutilisation sup rieure 5 ans nous recommandons de faire inspecter la valve par un centre de service agr afin d viter tout dom mage R parations les r parations sont effectu es uniquement par Moog ou par un partenaire autoris Des valves r par es ou des valves de remplacement sont livr es avec des r glages correspondant ceux d une valve neuve Par suite une v rification de la configuration et une modification des param tres doivent tre effectu es avant r installation Si besoin l utilisateur devra restaurer la configu ration et les param tres d origine introduits par le fabricant de la machine 10 Lors de la mise au rebut d chets Lors de la mise au rebut en d ch terie de la commande ac cessoire emballage fluide hydraulique et nettoyant la r gle mentation en vigueur s
36. tauschventilen erfolgt wie bei neuen Ventilen mit Werkseinstellung Daher m ssen die Ventile vor der Wieder inbetriebnahme auf korrekte Konfiguration und eventuell ge n derte Parametrierung berpr ft werden Der Anwender muss ggf die urspr ngliche Konfiguration und Parametrierung des Herstellers der Maschinenanlage wiederherstellen Montage und Inbetriebnahme Hinweise D636 7 8 9 B97072 636 002 Version G 02 15 2003 2006 2008 2009 2010 Moog GmbH Alle Rechte vorbehalten nderungen vorbehalten Hanns Klemm Str 28 71034 B blingen GERMANY www moog com industrial 10 Entsorgung Bei der Entsorgung der Ventile der Ersatzteile oder des Zube h rs der nicht mehr ben tigten Verpackungen der Hydraulik fl ssigkeit oder der zur Reinigung verwendeten Hilfsmittel und Substanzen m ssen die jeweils landesspezifisch g ltigen Ent sorgungsvorschriften und Umweltschutzbestimmungen beach tet werden Montage und Inbetriebnahme Hinweise D636 7 8 9 B97072 636 002 Version G 02 15 Seite 3 3 Manuel de l utilisateur Instructions de mise en service Series D636 7 8 9 Servovalves 1 Securite Maniement des commandes hydrauliques installations AVERTISSEMENT Manipulation sur les commandes pendant le fonctionnement Tout type de manipulation durant le fonctionnement par exemple la connexion des composants peut cau ser des mouvements incontr l s et des malfonction nements dont peuvent resulter des dommage
37. ur le traitement des d chets dans le pays concern doit tre appliqu e Instructions de mise en service D636 7 8 9 B97072 636 003 Version G 02 15 Tous droits r serv s 2003 2006 2008 2009 2010 Moog GmbH Sous r serve de modifications Hanns Klemm Str 28 71034 B blingen GERMANY www moog com industrial Manuale dell utilizzatore Istruzioni di montaggio ed installazione Serie D636 7 8 9 Servovalvole 1 Sicurezza Maneggiare valvole impianti meccanici A Istruzioni di montaggio ed installazione D636 7 8 9 B97072 636 004 Versione G 02 15 AVVERTENZA Lavorare sulle valvole impianti meccanici du rante il funzionamento I lavori che vengono eseguiti durante il funziona mento come per es l allacciamento idraulico di com ponenti possono causare movimenti non controllati disfunzioni ed altro e di conseguenza possono por tare a decessi gravissime lesioni corporee e notevoli danni materiali Non eseguire alcun lavoro su valvole durante il loro funzionamento impianti meccanici gt Fermare l intero impianto e disinserire l alimenta zione elettrica prima di iniziare a lavorare su val vole impianti meccanici Assicurare l impianto meccanico contro un even tuale riaccensione Esempi per adeguate misure di sicurezza Chiudere il quadro generale di comando e to gliere la chiave e Applicare un cartello di avvertimento sull inter ruttore generale AVVERTENZA Fuorius
38. utilisation d alimentations SELV PELV Page 2 2 Signal nominal Se r f rer la plaque signal tique Fusible externe par commande 2 0 A fusible moyennement retard pour D636 8 ou 3 15 A fusible moyennement retard pour D637 9 Sens de fonctionnement Un signal positif D E pour connecteur 6 PE ou 4 5 pour connecteur 11 PE provoque une ouverture de la valve dans le sens P gt A C blage connecteur Voir le sch ma de c blage sur l ti quette du bo tier lectronique au catalogue ou au plan d en combrement Raccordement C bles prot g s la protection doit tre rac cord e aux deux extr mit s et galement connect e au 0 V de r f rence du c t contr leur am lioration CEM Raccorder la mise la terre Observer les instructions de la note technique TN 353 6 Mise en service du syst me hydraulique Porter une attention particuli re au r glage de la pression la purge du circuit et aux signaux d alarme 7 Purge seulement D638 9 AVERTISSEMENT Fuite de fluide hydraulique Une forte pression peut entra ner des projections de liquide hydraulique ou l expulsion de certaines pi ces Ces ph nom nes peuvent causer de graves blessures corporelles des br lures et des incendies Commande et cylindre sont purger une pres sion inf rieure 10 bar gt Ouvrir d un tour la vis de purge 8 Adjustement du z ro L ajustement du z ro et les autres param tres peuven