Home

Manual TR-PW32-1

image

Contents

1. may lead to mortal electrical shock More severe dirt in and at the device should only be removed by a specialist There must never enter any liquid into power outlets extensions cords or any holes in the housing of the device If you suppose that also a minimal amount of liquid may have entered the device it must immediately be disconnected This also valid if the device was exposed to high humidity Also if the device is still running the device must be checked by a specialist if the liquid has reduced any insulation Reduced insulation can cause mortal electrical shock There must never be any objects entering into the device This is especially valid for metal parts If any metal parts like stapless or coarse metal chips enter into the device the device must be taken out of operation and disconnected inmediately Malfuction or short circuits cause by metal parts may cause mortal injuries Keep away children and amateurs Never leave this device running unattended Operating determinations This device is a power distributor for for supplying current to other devices This product is only allowed to be operated with an alternating voltage of 380 400 V 50 Hz and was designed for indoor use only User manual Power Distributor TR PW32 1 Triton Blue Rev Sep 2013 www triton blue com The maximum power consumption of this device must never be exceeded This device must never be operated or stockpiled in sourrounding where splash water ra
2. POWER DISTRIBUTOR TR PW32 1 MANUAL DE USARIO USER MANUAL POWER DISTRIBUTOR a N FAULT CURRENT CIRCUIT TR PW32 1 User manual Power Distributor TR PW32 1 Triton Blue Rev Sep 2013 www triton blue com CASTELLANO Por su propia seguridad por favor lea este manual del usuario antes de la conexion inicial Toda persona implicada en la instalaci n operaci n y mantenimiento de este aparato tiene que Estar cualificado Seguir las instrucciones de este manual Considere este manual como parte del producto total Conserve este manual durante toda la vida til del producto Pasar el manual a cada sucesivo poseedor o el uso del producto Descarga la ltima versi n del manual del Internet en www triton blue com Introducci n Gracias por haber elegido un Power Distributor TR PW32 1 Si usted sigue las instrucciones de este manual estamos seguros de que podr disfrutar de este dispositivo durante un largo periodo de tiempo Si el aparato ha estado expuesto a grandes cambios de temperatura por ejemplo tras el transporte no lo enchufe inmediatamente El agua condesation producida podr a da ar su aparato Dejelo apagado hasta que se haya alcanzado la temperatura ambiente Por favor aseg rese de que no hay da os evidentes de transporte Si observa cualquier da o en el cable de conexi n de A C o en la caja no use el aparato y de inmediato consulte a distribuidor local Este aparato pertenece
3. a la clase de protecci n La conexi n en CETAG s lo debe ser conectado a una toma corriente CETAG La tensi n y la frecuencia debe ser exactamente la misma que aparece en el dispositivo Usar voltajes o conectores inapropiados pueden llevar a la destrucci n del aparato o causar un shock el ctrico mortal Conectar siempre la clavija de alimentaci n al final La clavija debe ser insertada sin fuerza Aseg rese de que la clavija est firmemente conectada con el enchufe Nunca deje el cable de alimentaci n entre en contacto con otros cables Maneje el cable de alimentaci n y todas las conexiones principales con mucha precauci n Nunca los toque los cables con las manos mojadas ya que esto podr a dar lugar a una descarga el ctrica mortal Nunca modifique o doble a tensi n mec nica puede provocar calentamiento en el cable de alimentaci n Nunca opere cerca de fuentes de calor o de fr o Estas indiferencias puede conducir a da os del cable de alimentaci n incendio o choque el ctrico mortal La boquilla del cable o el conector del aparato no debe ser cargado con tracci n Siempre debe haber suficiente cable en el dispositivo De lo contrario el cable puede ser estropeado y puede conducir a da os mortales Aseg rese de que el cable de alimentaci n no quede nunca enganchado o da ados por bordes afilados Compruebe el dispositivo y el cable de alimentaci n de vez en cuando Si se utilizan cables de extensi n aseg rese de qu
4. de 5 pines y cable de 5 x 6 mm2 Interruptor diferencial 40mA como protecci n Display para medici n de voltage e intensidad por fase Una salida mediante conector de 32 Amperios de 3P N T 6 conectores tipo schuco en la parte trasera 2 por fase Cada salida de conector schuco esta protegida mediante magnetotermico de 16 Amperios Panel frontal 1 Voltimetros 2 Amperimetros 3 Magnetotermicos para protecci n de salidas 4 Bot n de test 5 Interruptor de diferencial User manual Power Distributor TR PW32 1 Triton Blue Rev Sep 2013 www triton blue com POWER INPUT AC380 400V O 50Hz i O O O 32A OUTPUT d y Q Q Panel trasero 6 Entrada de corriente mediante cable 32 A 7 Salida de 32 A mediante conector 8 Salida mediante conector schuco fase 3 9 Salida mediante conector schuco fase 2 10 Salida mediante conector schuco fase 1 Instalaci n El operador tiene que asegurarse de que la seguridad y el distribuidor son inspeccionados por un experto antes de tener funcionamiento la primera vez y despu s de los cambios antes de otra puesta en marcha Instalaci n en Racks Este Distribuidor de 32 Amperios 32A se construye para bastidores de acero 19 estandar 483 mm El rack que usted use debe ser con doble puerta donde se p
5. e el di metro del n cleo es suficiente para el consumo de energ a requiedo del dispositivo Todas las advertencias acerca de los cables de alimentaci n son tambi n v lidas para posibles extensiones Desconecte siempre de la red el ctrica cuando el aparato no est en uso y antes de limpiarlo Utilice solamente el cable de alimentaci n con la clavija Nunca extraiga la clavija tirando del cable de alimentaci n de lo contrario el cable o el enchufe puede ser da ado conduciendo a una possible descarga el ctrica mortal Si los enchufes o interruptores no son accesibles el aparato debe ser desconectado de la red el ctrica Si el cable de alimentaci n o el dispositivo est n sucios el dispositivo debe estar fuera de servicio desconectase y limpielo con un pa o seco El polvo puede reducir la protecci n y puede causar un golpe el ctrico mortal Si la suciedad es muy alta M s el dispositivo debe ser revisado por un especialista Nunca debe entrar ning n l quido en las tomas de corriente cables de extensiones u orificios en la carcasa del dispositivo Si usted supone que tambi n una cantidad m nima de l quido puede haber entrado en el aparato ste debe ser inmediatamente desconectado Esto tambi n es v lido si el aparato fue expuesto a alta humedad Ademas si el dispositivo sigue funcionando el dispositivo debe ser controlado por un especialista el liquid puede reducer el aislamiento Reducci n el aislamiento puede provocar una d
6. e rack should be provided with a cooling fan When mounting tne 19 distributor into the rack please make sure that there is enough space around the device so that the heated air can be passed on Steady overheating will damage your device You can fix the 19 distributor with four M6 screws in the rack Be careful when mounting the 19 distributor into the rack Put the heaviest devices into the lower part of the rack Connections Connection with the mains Connect device to the mains with the CEE plug The earth has to be connected If the device will be directly connected with the local power supply network a disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical installation Outputs Output is via six safety sockets and one 32A three phase current output socket Connect your loads via the output sockets The maximum load per channel is 3 680 W resistive and 22080 W respectively Please note that the maximum current must never be exceeded Technical Specifications Power suppl 380 400 V AC 50 Hz Max power output 22080 W Max output phase 7360 W Max current phase 32 A BRA S O Fuses 6x 16A 1 Ph FI RCD 40A 0 03A BU Height 3 U Dimmensions 482 x 230 x 133 mm 65kg o OO Weight 6 5 kg User manual Power Distributor TR PW32 1 Triton Blue Rev Sep 2013 www triton blue com
7. escarga el ctrica mortal Nunca debe haber objetos que del dispositivo Esto es especialmente v lido para las piezas de metal Si alguna pieza de metal como virutas de metal grapas u otros entran en el dispositivo el dispositivo debe estar fuera de servicio y desconectarlo inmediatamente Una mal funci n o cortocircuitos por causa de piezas de metal pueden causar lesiones mortales Mantener alejado ni os y aficionados Nunca el aparato no puede en funcionar sin vigilancia Instrucciones de manejo Este dispositivo es un distribuidor de energ a para suministrar corriente para a otros dispositivos El aparato s lo es permitido para una conexion con una tensi n alterna de 380 400 V 50 Hz y ha sido dise ado para uso en interiores El consumo maximo de energia de este aparato no se debe sobrepasar Al elegir el sitio de instalacion por favor asegurese de que el aparato no esta expuesto a calor extremo humedad o polvo No debe haber cables mal instalados Puede poner en peligro su propia seguridad y la de los demas Este dispositivo no debe trabajar o almacenar en un lugar interior donde hay agua proyectada Iluvia humedad o humo La humedad o humedad muy alta puede reducir la protecci n y causar un golpe el ctrico mortal Cuando se emplean m quinas de humo aseg rese de que el dispositivo no est expuesto al chorro de humo directo y se instala en una distancia de 1 00 metros entre la m quina de humo y el dispositivo La temperatu
8. for installation 32 A three phase current input via 5 x 6 mm2 power cable and plug The entire distributor is secured via 30 mA Residual Current Device RCD Voltage and current display of every phase 32 A three phase current output on the rearpanel 6 safety sockets on the housing back 2 per phase Each safety socket feature fuse protection via 16 A automatic circuit breakers With M6 earthing screw in order to ground a rigg if necessary Frontpanel e y 1 Volt meter 2 Ampere meter 3 Circuit breaker for power distribution schets rearpanel 4 Test button 5 Residual Current Device RCD Rearpanel POWER INPUT AC380 400V O 50Hz O O 32A OUTPUT d A Q 6 32 A three phase current input plug 7 32 A three phase current output socket 8 Phase 3 power outlet 9 Phase 2 power outlet 10 Phase 1 power outlet Installation The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time Rack installation This 19 distributor 32A is built for 19 racks steel cabinets 483 mm The rack you use should be a double door rack where you can open the frontpanel and the rear panel Th
9. has to Be qualified Follow the instructions of this manual Consider this manual to be part of the total product Keep this manual for the entire service life of the product Pass this manual on to every further owner or use of the product Download the last version of the user manual from the internet in www triton blue com Introduction Thank you for having chosen a Power Distributor TR PW32 1 If you follow the instructions given in this manual we are sure that you will enjoy this device for a long period of time If the device has been exposed to drastic temperature fluctuation eg after transportation do not switch it on immediately The arising condensation water might damage your device Leave the switched off until it has reached room temperature Please make sure that there are no obvious transport damages Should you notice any damages on the A C connection cable or on the casing do not take the device into operation and immediately consult you local dealer This device falls under protection class The CETAG plug must only be plugged into a CETAG outlet The voltage and frequency must exactly be the same as stated on the device Wrong voltages or power outlets can lead to the destruction of the device and to mortal electrical shock Always plug in the power supply plug least The power plug must always be inserted without force Make sure that the plug is tightly connected with the outlet Never let the power cord co
10. in moisture or fog may harm the device Moisture or very high humidity can reduce the insulation and lead to mortal electrical shocks When using smoke machines make sure that the device is never exposed to the direct smoke jet and is installed in a distance of 1 00 meters between smoke machine and device The ambient temperature must always be between 5 C and 45 C Keep away from direct insulation and heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C Operate the device only after having familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation Never use solvents or aggresive detergents in order to clean the device Rather use a soft and damp cloth Please use the original packaging if the device is to be transported Inspection deadlines according to BGV A2 for electrical resources must be complied with Please consider that unauthorized modifications on the device are forbidden due to safety reasons If this device will be operated in any way different to the one described in this manual the products may suffer damages and the guarantee becomes void Also any other operation may lead to dangers like short circuits burns electric shock crash etc Description of the device Features Practical 32 A distributor in 19 housing Specially designed for larger distribution needs 3 U necessary
11. me into contact other cables Handle the power cord and all connections with the main with particular caution Never touch them with wet hands as this could lead to mortal electrical shock Never modify bend strain mechanically put pressure on pull or heat up the power cord Never operate next to sources of heat or cold Disregard can lead to power cord damages fire or mortal electrical shock The cable insert or the female part in the device must never be strained There must always be sufficient cable to the device Otherwise the cable may be damaged which may lead to mortal damage Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time If extension cords are used make sure that the core diameter is sufficient for the required power consumption of the device All warning concerning the power cords are also valid for possible extension cords Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Otherwise the cable or plug can be damaged leading to mortal electrical shock If the power plug or the power switch is not accessible the device must be disconnected via the mains If the power plug or the device is dusty the device must be taken out of operation disconnected and the be cleaned with a dry cloth Dust can reduce the insulation which
12. ra ambiente debe ser entre 5 C y 45 C Mantener alejado del sol directo y calentadores La humedad relativa no debe superar el 50 en una temperatura ambiente de 45 C Nunca utilice el aparato durante tormentas El sobre voltaje podr a destruir el dispositivo Siempre desconectar el aparato durante tormentas el ctricas Maneje el aparato s lo despu s de familiarizarse con sus funciones No permita el manejo a personas que no conocen el aparato La mayor a de los da os son causados por manejo inadecuado de inexpertos No utilice disolventes o detergentes agresivos para limpiar el aparato Utilice mejor un pa o suave y h medo Utilice el embalaje original cuando el aparato deba ser transportado Los plazos de inspecci n seg n BGV A2 de recursos el ctricos deben ser respetadas Tenga en cuenta que las modificaciones no autorizadas del aparato est n prohibidas por razones de seguridad Si se va a operar este dispositivo en modo diffente a la descrita en este manual los productos pueden sufrir da os y la garant a expira Ademas todos los usos diferentes pueden causar peligros como cortocircuitos quemaduras descargas el ctricas golpes etc Descripci n del Distribuidor Caracter sticas Distribuidor de energia montado en rack de 19 Especialmente dise ado para las necesidades de distribuci n de energia Necesita 3 unidades de rack para la instalaci n Entrada de corriente trifasica de 32Amperios con conector CEE
13. uede abrir el panel frontal y el panel trasero El bastidor debe estar provisto de un ventilador de refrigeraci n Al montar el distribuidor en el bastidor aseg rese de que hay suficiente espacio alrededor del aparato para que el aire caliente se puede transmitir Sobrecalentamiento continuo puede da ar el dispositivo Usted puede fijar el distribuidor con cuatro tornillos M6 en el rack Tenga cuidado al montar el distribuidor en el rack Ponga los dispositivos m s pesados en la parte inferior del rack Conexiones Las conexiones con la red el ctrica Conecte el dispositivo a la red el ctrica con el enchufe CEE La tierra debe ser conectada Si el dispositivo es conectado directamente con a la red de suministro de energ a local un interruptor de red con una apertura m nima de 3 mm en cada polo tiene que ser incluido en la instalaci n el ctrica permanente Salidas La salida se realizan a trav s de seis conectores tipo schuko y una toma de salida de 32A trif sico de corriente tipo CEE Conecte sus cargas a trav s de los conectores La carga m xima por canal es de 3 680 W resistiva y 22 080 W respectivamente Por favor tenga en cuenta que la corriente m xima no debe ser excedida Especificaciones t cnicas 32 A EXI Dimensiones ENGLISH For your own safety please read this user manual carefully before you initially start up Every person involved with the installation operation and maintenance of this device

Download Pdf Manuals

image

Related Search

Related Contents

  Télécharger - Case Construction  FGS-VC Series Motorized Stand  Instrucciones de juego de instalación por encima de la cama y tubo  SILVER WINE COOLER    LL50A - Insatech  Guide Photo - A Little Mercerie  La Bibliographie de Belgique - Koninklijke Bibliotheek van België  0088-240-157 http://www.softbank.jp 0088-241-157 0088-242  