Home
Centrifugal Pumps Bombas Centrífugas
Contents
1. Symptom Possible Cause s Corrective Action Failure to pump Pump not property primed Make sure pump casing and suction line are full of water See priming instructions Air pockets or leaks in suction line Check suction piping Reduced capacity and or pressure Clogged impeller Remove and clean Air leaks in suction line Check suction piping Excessive suction lift and operating too near Move pump nearer water level Pump loses prime shut off point Water level drops while pumping uncovering Check water supply Add length of pipe to suction to keep submerged suction piping end under water Bent shaft and or damaged bearings Take motor to authorized motor repair shop Mechanical troubles and noises Suction and or discharge piping not properly supported and anchored See that all piping is supported to relieve strain on pump assembly Repair Parts 8 Ref Description Qty Part Number 1 Motor 115 230V 1 A100ELL 2 Capscrew 3 8 16 x 1 1 4 Lg 2 U30 75ZP 3 Waster Slinger 1 17351 0009 4 Seal Plate 1 C3 1042P 5 Gasket 1 C20 121 6 Shaft Seal 1 U109 6B 7 Impeller 1 C105 92PL 8 Wear Ring 1 23 27 9 Volute Assembly With Wear Ring 1 C101 284E 10 Pipe Plug 1 4 NPT Hex Head 3 U78 941ZPV 11 Base With Motor Pad 1 J4 9 12 Capscrew 3 8 16 x 1 1 2 Lg 2 U30 76ZP 13 Motor Pad 1 C35 5 Seguridad Instrucciones importan
2. Keep safety labels in good condition Replace missing or damaged safety labels Wire motor for correct voltage See Electrical section of this manual and motor nameplate A Ground motor before connecting to power supply Meet National Electrical Code Canadian Electrical Code and local codes for all A WARNING lt Hazardous voltage Can shock burn or cause death wiring Ground pump before Follow wiring Connecting to power instructions in this supply Disconnect power before working on pump motor or tank manual when connecting motor to power lines Electrical Safety A WARNING Risk of electric shock Can shock burn or kill Disconnect power to pump before working on pump or motor Disconnect pump from power before servicing or handling pump If in doubt consult a qualified electrician General Safety A CAUTION Risk of burns Do not touch an operating motor Motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling Do not allow pump or any system component to freeze To do so will void warranty Pump water only with this pump Periodically inspect pump and system components Wear safety glasses at all times when working on pumps Keep work area clean uncluttered and properly lighted store properly all unused tools and equipment Keep visitors at a safe dis
3. Tornillo de Cabeza 3 8 16 x 1 1 4 de largo 2 U30 75ZP 3 Deflector 1 17351 0009 4 Placa Obturadora 1 C3 1042P 5 Empaquetadura 1 C20 121 6 Junta del Eje 1 U109 6B 7 Impulsor 1 C105 92PL 8 Anillo de Desgaste 1 23 27 9 Voluta Con Anillo de Desgaste 1 C101 284E 10 Tap n 1 4 NPT cabeza hexagonal 3 U78 941 ZPV 11 Base Con Amortiguador del Motor 1 J4 9 12 Tornillo de Cabeza 3 8 16 x 1 1 2 de largo 2 U30 76ZP 13 Amortiguador del Motor 1 C35 5 I5
4. a los bornes L1 y L2 bajo el techo del motor Cuando cambie el motor b sese en el diagrama del motor 8 El motor tiene una protecci n autom tica interna de sobrecarga t rmica si el motor se ha detenido por razones desconocidas la sobrecarga t rmica puede volver a arrancarlo sorpresivamente lo que podr a causar lesiones o da os a la propiedad Desconecte el suministro de corriente antes de reparar el motor 9 Si este procedimiento o los diagramas de cableado son dif ciles de entender consulte con un electricista certificado Cuadro de cableado tama os de cables y fusibles recomendados Distancia en pies metros del motor a la fuente de suministro a Amperios de Ps or 0 100 101 200 201 300 301 400 401 500 carga m xima en amp 0 30 31 61 62 91 92 122 122 152 Tama o del cable AWG mm 115 230 14 8 7 4 20 15 12 14 3 2 10 14 5 5 2 8 14 8 4 2 6 14 14 2 4 10 21 5 5 Para todos los circuitos del motor se recomienda el uso de fusibles de doble elemento o del tipo Fustron con retardo de tiempo Localizaci n de fallas 14 A ADVERTENCIA Riesgo de choque el ctrico cuchilla peligrosa y posibles arranques inesperados Puede provocar choque el ctrico o apretar las manos o las herramientas Si la corriente a la bomba est conectada cuando se repone el protector t rmico de sobrecarga la bomba podr arrancar inesperadamente Desconecte la co
5. a tierra antes de conectarla a la alimentaci n el ctrica Desconecte la alimentaci n de energ a antes de trabajar A en la bomba el motor o el tanque Siga las instrucciones de conexi n el ctrica en este manual al conectar el motor a las l neas de energ a el ctrica Seguridad electrica A ADVERTENCIA Riesgo de choque el ctrico Puede provocar choque quemadura o muerte Desconecte la alimentaci n de energ a de la bomba antes de trabajar en ella o en el motor Desconecte la bomba del suministro el ctrico antes de darle servicio a la bomba o de manejarla Seguridad general A PRECAUCI N Riesgos de quemaduras No toque un motor en operaci n Los motores est n dise ados para operar a temperaturas altas Para evitar quemaduras al realizar el servicio a una bomba d jela enfriar por 20 minutos despu s de apagarla No permita que la bomba o cualquier componente del sistema se congele Hacerlo invalidar la garant a Utilice esta bomba s lo para agua Inspeccione la bomba y los componentes del sistema peri dicamente Utilice gafas de seguridad durante todo el tiempo mientras trabaje en la bomba El rea de trabajo se debe mantener limpia ordenada y con iluminaci n adecuada guarde las herramientas y el equipo que no utilice en el lugar apropiado Mantenga a los visitantes a una distancia segura de las reas de trabajo A ADVERTENCIA Peligro de explosi n El cuerpo de la bomba pued
6. COUNTYLINE TRACTOR SUPPLY C 293 Wright Street Delavan WI 53115 Phone 1 800 535 4950 Fax 1 800 526 3757 Web Site tractorsupply com OWNER S MANUAL Centrifugal Pumps MANUAL DEL USUARIO Bombas Centrifugas CLCP 100 Installation Operation Parts For further operating installation or maintenance assistance Call 1 800 535 4950 English Pages 2 8 02011 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 535 4950 Espa ol P ginas 9 15 CL125 11 21 11 Safety Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation operation and maintenance of the product Save this manual for future reference A This is the safety alert symbol When you see this symbol on your pump or in this manual look for one of the following signal words and be alert to the potential for personal injury indicates a hazard which if not avoided will result in death or serious injury AWARNING indicates a hazard which if not avoided could result in death or serious injury A CAUTION indicates a hazard which if not avoided could result in minor or moderate injury NOTICE addresses practices not related to personal injury Carefully read and follow all safety instructions in this manual and on pump
7. V 60 Hz Gama de la temp del liquido Menos de 120 F 50 C SUCCO tio e Gyo E a th E E AAA A 1 1 4 FNPT Desc ssk aek nc Sin wis aaia ea achive 1 FNPT AAA a A AE E 45 1 0 Vea la Cuadro de cableado Rendimento Rendimiento en Gal por Min a las Presiones de Descarga Indicadas 25 30 35 40 45 50 Lbs pulg Max 47 40 35 29 17 49 Figura l Los sitios t picas Ref F T A Tap n de cebado G Base H Fundaci n s lida y nivelada J Soportes de tuber a K Tuber a de succi n B V lvula de compuerta C Descarga de la bomba D Codo E Uni n L V lvula de aspiraci n Tuberias Tanto la tuber a de aspiraci n como la de descarga deben estar independientemente apoyadas en un punto cerca de la bomba a fin de evitar los esfuerzos ejercidos en la bomba Comenzar a colocar todas las tuber as desde el lado de la bomba a fin de evitar los esfuerzos que puede causar un espacio Se aconseja aumentar el di metro de la tuber a de aspiraci n y de descarga en la bomba si se requiere un largo apreciable de tuber a Nunca usar una tuber a de aspiraci n de un di metro m s peque o que la conexi n de la aspiraci n en la bomba Usar una llave para sujetar el reborde de la aspiraci n y de la descarga de la bomba cuando se est conectando la tuber a a fin de evitar poner demasiado esfuerzo en la bomba Tuberia de aspiracion El tubo de aspiraci n no debe tener p rdidas
8. ba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de CountyLine Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si su bomba cloacal ha fallado e Use guantes de caucho cuando manipule la bomba e Para los fines de la garant a devuelva la etiqueta del cord n de la bomba y el recibo de compra original a la tienda minorista e Descarte la bomba cumpliendo con todas las normas locales que correspondan para su eliminaci n Excepciones para la garant a limitada de doce 12 meses Producto Per odo de garant a CL106 CL108 90 d as CLTS33P CLSU14 2 a os Tanque del sistema de agua CLVS50C CLW750 5 a os T rminos y condiciones generales Limitaci n de recursos Usted deber pagar por todos los gastos de mano de obra y de env o necesarios para reemplazar el producto cubierto por esta garant a Esta garant a no se aplicar en las siguientes situaciones 1 caso de fuerza mayor 2 productos que a s lo juicio de CountyLine hayan sido sometidos a negligencia abuso accidente mala aplicaci n manejo indebido o alteraciones 3 fallas debido a instalaci n operaci n mantenimiento o almacenamiento inadecuados 4 aplicaciones usos o servicios que no sean normales o aprobados 5 fallas provocadas por corrosi n herrumbre u otros materiales extra os en el sistema o una operaci n a pres
9. da consulte con un electricista certificado Procedimiento de conexi n 1 Instale ponga a tierra conecte los cables y mantenga esta bomba conforme a los requisitos del c digo el ctrico Consulte a su inspector local de construcciones para obtener informaci n sobre los c digos 2 Suministre un interruptor de desconexi n con el fusible correcto para protecci n mientras se trabaja con el motor Consulte los c digos el ctricos locales o nacionales con respecto a los requisitos para interruptores 13 3 Desconecte la corriente antes de reparar el motor o la bomba Si el interruptor de desconexi n est fuera de la vista de la bomba tr belo en posici n abierta y ponga un etiqueta para evitar que se aplique la corriente accidentalmente 4 Conecte la bomba a tierra en forma permanente usando un alambre del mismo tama o que el especificado en la tabla de cableado Haga la conexi n a tierra con el borne verde de puesta a tierra bajo el techo que est marcado GRD o 5 Conecte el alambre de puesta a tierra a un cable de ida a tierra en el tablero de servicio o a una tuber a de metal para agua subterr nea o una envoltura para pozos de por lo menos 10 pies de largo No conecte a un tubo de pl stico o a accesorios aislados 6 Proteja los conductores de puesta a tierra y los que llevan la corriente contra cortes grasa calor aceite y productos qu micos 7 Conecte los conductores que llevan la corriente
10. de aire Cualquiera que sea el largo horizontal de la tuber a de aspiraci n debe tener una pendiente ascendente gradual hacia la bomba Evitar cualquier conector que pueda causar una trampa de aire Se debe instalar una v lvula de aspiraci n para evitar que la bomba se descebe Tuberia de descarga Se debe instalar una v lvula de compuerta y una uni n en la tuber a de descarga Para sacar la bomba y prestarle servicio cerrar la v lvula de compuerta y desconectar la uni n Cebado de la bomba Cebar la bomba llenando completamente de agua tanto la tuber a de aspiraci n como la bomba a trav s de la t de cebado Volver a colocar el tap n de cebado y poner en marcha la bomba Si el agua no es bombeada inmediatamente es porque no se ha evacuado todo el aire Parar la bomba y volver a cebar siguiendo las instrucciones anteriores Cuando la descarga sea vertical debe aflojarse el tap n de ventilaci n situado en la parte superior para evacuar el aire que est atrapado dentro de la voluta Cuando la voluta se ha llenado completamente de agua apretar el tap n de ventilaci n A ADVERTENCIA Riesgo de exposion y quemaduras NUNCA haga funcionar la bomba si la descarga est cerrada Si lo hace el agua que est dentro de la bomba puede hervir causando una presi n peligrosa en la bomba riesgo de explosi n y posiblemente quemaduras a las personas que manipulan la bomba A PRECAUCI N Riesgos de quemaduras NUNCA haga funciona
11. e explotar si se utiliza como una bomba propulsora a menos que se instale una v lvula de alivio que sea capaz de pasar todo el flujo de la bomba a 75 psi ES OS Ah ADVERTENCIA Presi n peligrosa Instale una v lvula de alivio de presi n en la tuber a de descarga Libere toda la presi n en el sistema antes de trabajar en alguno de los componentes Garant a 10 Retener el recibo original a fin de determinar la elegibilidad para la garant a Garant a limitada Esta Garant a Limitada entra en vigor el 01 de diciembre 2011 y sustituye toda garant a sin fecha o garant a con fecha anterior al 1 de diciembre de 2011 CountyLine le garantiza al comprador consumidor original el Comprador o Usted de sus productos que stos estar n libres de defectos en materiales y en mano de obra por un per odo de doce 12 meses a partir de la fecha de la compra original del consumidor si dentro de los doce 12 meses a partir de la fecha de la compra inicial del consumidor Ser reparado o reemplazado a opci n de la CountyLine sujeto a los t rminos y condiciones establecidos en la presente Tome nota de que esta garant a limitada cubre defectos de manufactura solamente y no el desgaste com n Todos los aparatos mec nicos peri dicamente necesitan repuestos y servicio para un funcionamiento correcto Esta garant a limitada no cubre las reparaciones que se realicen cuando el uso normal haya agotado la
12. ility is based on purchase date of original product not the date of replacement under warranty The warranty is limited to repair or replacement of original purchased product only not replacement product i e one warranty replacement allowed per purchase Purchaser pays all removal installation labor shipping and incidental charges For parts or troubleshooting assistance DO NOT return product to your retail store Contact CountyLine Customer Service at 1 800 535 4950 Claims made under this warranty shall be made by returning the product except sewage pumps see below to the retail outlet where it was purchased or to the factory immediately after the discovery of any alleged defect CountyLine will subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expires Warranty is not transferable and does not apply to products used in commercial rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed e Wear rubber gloves when handling the pump e For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store e Dispose of the pump according to local disposal ordinances Exceptions
13. iones que excedan los m ximos recomendados Esta garant a establece la nica obligaci n de CountyLine y el recurso exclusivo del Comprador con respecto a los productos defectuosos COUNTYLINE NO SE HAR RESPONSABLE DE NING N DA O CONSECUENTE INCIDENTAL O CONTINGENTE LAS GARANT AS LIMITADAS QUE ANTECEDEN SON EXCLUSIVAS Y EN LUGAR DE TODA OTRA GARANT A EXPL CITA E IMPL CITA INCLUYENDO PERO SIN LIMITARSE A LAS GARANT AS IMPL CITAS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN ESPEC FICO LAS GARANT AS LIMITADAS QUE ANTECEDEN NO SE EXTENDER N M S ALL DEL PER ODO DE DURACI N INDICADO EN LA PRESENTE Algunos Estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes o de limitaciones de tiempo sobre garant as impl citas de modo que es posible que las limitaciones o exclusiones que preceden no correspondan en su caso Esta garant a le otorga derechos legales espec ficos y es posible que Usted tambi n tenga otros derechos que pueden variar de un Estado al otro CountyLine 293 Wright Street Delavan WI U S A 53115 Tel fono 1 800 535 4950 Fax 1 800 526 3757 Sitio Web tractorsupply com Instalaci n Descripci n Esta bomba est dise ada para necesidades de bombeo de aguas clara de prop sito general Ofrece abundante agua a diferentes presiones Puede extraer agua de los estanques cisternas o pozos Especificaciones Fuente de alimentaci n a n ananuna uann 115
14. ire before connecting power supply wires Use the wire size including the ground wire specified in the wiring chart Connect the pump to a separate branch circuit with no other appliances on it 44 WARNING Risk of explosion Do not ground to a gas supply line AWARNING Risk of electric shock Can shock burn or kill To avoid dangerous or fatal electrical shock turn OFF power to motor before working on electrical connections AA WARNING Risk of fire Incorrect voltage can cause a fire or seriously damage the motor and voids the warranty The supply voltage must be within 10 of the motor nameplate voltage If in doubt consult a licensed electrician Connection Procedure 1 Install ground wire and maintain this pump in accordance with electrical code requirements Consult your local building inspector for information about codes 2 Provide a correctly fused disconnect switch for protection while working on motor Consult local or national electrical codes for switch requirements 6 3 Disconnect power before servicing motor or pump If the disconnect switch is out of sight of pump lock it open and tag it to prevent unexpected power application 4 Ground the pump permanently using a wire of the same size as that specified in wiring chart below Make ground connection to green grounding terminal under motor canopy marked GRD or 5 Connect ground wire to a grounded lead in the service
15. le run of pipe is required Never use a smaller suction pipe than the suction connection on the pump Use a pipe wrench to hold the suction and discharge bosses of the pump while making up the piping to avoid putting excess strain on the pump Suction Pipe The suction pipe must be kept free from air leaks Any horizontal run of suction piping must have a gradual upslope towards the pump Avoid any fittings which may cause an air trap A foot valve should be installed to prevent loss of pump prime Discharge Piping A gate valve and union should be installed in the discharge line For removal of the pump for service close the gate valve and disconnect the union Priming The Pump Prime pump by filling both the pump and suction line completely with water thru the priming tee Replace priming plug and start pump If water is not pumped immediately it is because all the air has not been evacuated Stop pump and reprime following instructions above When used with vertical discharge the vent plug at the top should be loosened to evacuate air which is trapped inside the volute When volute is completely filled with water tighten vent plug AWARNING Risk of explosion and scalding NEVER run pump against closed discharge To do so can boil water inside pump causing hazardous pressure in unit risk of explosion and possibly scalding persons handling pump A CAUTION Risk of burns NEVER run pump dry Running pump without water may cau
16. panel or to a metal underground water pipe or well casing at least 10 feet long Do not connect to plastic pipe or insulated fittings 6 Protect current carrying and grounding conductors from cuts grease heat oil and chemicals 7 Connect current carrying conductors to terminals L1 and L2 under motor canopy When replacing motor follow the diagram on the motor 8 Motor has automatic internal thermal overload protection If motor has stopped for unknown reasons thermal overload may restart it unexpectedly which could cause injury or property damage Disconnect power before servicing motor 9 If this procedure or the wiring diagrams are confusing consult a licensed electrician Wiring Chart Recommended Wire And Fuse Sizes Distance In Feet Meters From Motor To Supply Volts Max Load Amps ir Fuse 0 100 101 200 201 300 301 400 401 500 ating Amp 0 30 31 61 62 91 92 122 123 152 AWG Wire Size mm 115 230 14 8 7 4 20 15 12 14 3 2 10 14 5 5 2 8 14 8 4 2 6 14 14 2 4 10 21 5 5 Duel element or Fusetron time delay fuses recommended for all motor circuits Troubleshooting 7 42 WARNING Risk of electrical shock cuts and possible unexpected starts Can result in electrical shock or pinching of hands or tools If power to pump is on when thermal overload resets pump may start without warning Disconnect power before servicing pump
17. r la bomba en seco Si la bomba funciona sin agua puede recalentarse da ndose la junta y posiblemente causando quemaduras a las personas que manipulan la bomba Llenar la bomba con agua antes de ponerla en funcionamiento A PRECAUCI N Riesgos de quemaduras El motor normalmente funciona a altas temperaturas y estar muy caliente para tocarlo Esta protegido contra el da o que puede causar el calor durante el funcionamiento mediante un interruptor interno de cierre autom tico Antes de manipular la bomba o el motor pare el motor y d jelo enfriar durante aproximadamente 20 minutos Electricidad 12 A Desconecte la corriente antes de trabajar en la bomba el motor el conmutador a presi n o los cables A ADVERTENCIA Peligro de incendio Nunca conecte un motor de 115 voltios a una linea de 230 voltios Conversi n de voltaje 3 Use un destornillador o una llave de 1 2 y gire el cuadrante selector de tensi n hacia la izquierda hasta que se vea 115 en la abertura del cuadrante El tablero de bornes de su motor de doble tensi n debajo de la tapa de extremo del motor se parecer a uno de los diagramas que se ilustran a continuaci n Siga ese diagrama si es necesario convertir el motor a una potencia de 115 voltios Conecte los cables de suministro de corriente a L1 y L2 El motor se env a configurado para 230 voltios Para cambiar el motor y usarlo con 115 voltios 1 Desconecte la alimen
18. rriente antes de prestar servicio a la bomba Problema Causa s probable s Acci n correctiva Falla de la bomba La bomba no ha sido cebada debidamente Asegurarse de que el cuerpo de la bomba y la tuber a de aspiraci n est n llenas de agua Ver las instrucciones del cebado Reducci n de la capacidad o de la presi n Bolsillos de aire o p rdidas en la tuber a de aspiraci n Revisar la tuber a de aspiraci n Impulsor obstruido Sacar y limpiar La bomba se desceba P rdida de aire en la tuber a de aspiraci n Revisar la tuber a de aspiraci n Altura de aspiraci n excesiva y funcionamiento demasiado cerca del punto de parada Mover la bomba m s cerca del nivel del agua El nivel del agua desciende durante el bombeo dejando al descubierto la tuber a de aspiraci n Verificar la alimentaci n de agua Alargar el tubo de aspiraci n de modo que su extremo quede sumergido en el agua Aver as Mec nicas y Ruido Eje y o cojinetes da ados Llevar el motor a un taller de reparaci n autorizado Tuber a de aspiraci n y o de descarga mal apoyada o mal anclada Asegurarse de que toda la tuber a est debidamente apoyada para aliviar los esfuerzos en el conjunto de la bomba Piezas de repuesto Ref Descripci n Cant No de piezas 1 Motor 115 230 Voltios 60 Ciclos Monof sico 1 A100ELL 2
19. se pump to overheat damaging seal and possibly causing burns to persons handling pump Fill pump with water before starting A CAUTION Risk of burns Motor normally operates at high temperature and will be too hot to touch It is protected from heat damage during operation by an automatic internal cutoff switch Before handling pump or motor stop motor and allow it to cool for 20 minutes Electrical A Disconnect power before working on pump motor pressure switch or wiring AWARNING Risk of fire Never connect a 115 volt motor to a 230 volt line Voltage Conversion Your dual voltage motor s terminal board under the motor end cover will match one of the diagrams below Follow that diagram if necesary to convert motor to 115 Volt power Connect power supply wires to L1 and L2 The motor is set for 230 volts when shipped To change the motor to use 115 volts 1 Turn off power 2 Remove the back motor cover Figure 2 Changing the Voltage Setting 3 Use a screwdriver or 1 2 wrench and turn the voltage selector dial counterclockwise until 115 shows in the dial opening 4 Reinstall the motor cover A WARNING Risk of electric shock Can shock burn or kill Disconnect power to motor before working on pump or motor Ground motor before connecting to power supply Electrical Wiring Connections AWARNING Risk of electric shock Can shock burn or kill Connect ground w
20. sions may not apply to You This warranty gives You specific legal rights and You may also have other rights which vary from state to state CountyLine 293 Wright Street Delavan WI U S A 53115 Phone 1 800 535 4950 Fax 1 800 526 3757 Web Site tractorsupply com Installation Description This pump is designed for general purpose clear water pumping needs Delivers plenty of water at various pressures It can draw water from ponds cisterns or drilled wells Specifications Power supply required o ooo 115V or 230V 60 HZ Liquid Temp Range ooccoooo o o Less Than 120 F 50 C Suction Thread csi gi aire 1 1 4 FNPT Discharge Thread corras ee bee one 1 FNPT FOTSOPOWET si einant aois ndei Eie ae aA AOE AEA 1 0 See Wiring Chart Performance Performance in GPM at Discharge Pressure PSI Shown Max PSI 25 30 35 40 45 50 Figure l Typical Layouts Key F Priming Tee A Priming Plug G Pump Base B Gate Valve H Solid level foundation C Pump Discharge J Pipe Supports D Street El K Suction Piping E Union L Foot Valve Piping Both suction and discharge piping should be independently supported at a point near the pump to avoid strains being placed on the pump Start all piping at pump to avoid strains left by a gap Itis advisable to increase the size of both suction and discharge piping at the pump if any appreciab
21. taci n 2 Retire la cubierta posterior del motor MAHIIIA AAA A a Figura 3 Motor configurado para funcionar a 115 voltios 4 Vuelva a instalar la cubierta del motor A ADVERTENCIA Riesgo de choque el ctrico Puede provocar choque quemadura o muerte Desconecte la corriente al motor antes de trabajar en la bomba o en el motor Conecte el motor a tierra antes de conectarlo al suministro de corriente Figura 2 Cambio de la configuraci n de tensi n Electricidad Cableado A ADVERTENCIA Riesgo de choque el ctrico Puede provocar choque quemadura o muerte Desconecte la corriente al motor antes de trabajar en la bomba o en el motor Use alambres del tama o especificado en la Cuadro de Cableado Conecte la bomba a un circuito derivado separado sin otros aparatos conectados al mismo A ADVERTENCIA Riesgo de explosi n No haga la conexi n a tierra en una l nea de suministro de gas A ADVERTENCIA Riesgo de choque el ctrico Puede provocar choque quemadura o muerte Para evitar choques el ctricos peligrosos o fatales apague el motor antes de trabajar con conexiones el ctricas Conecte el motor a tierra antes de conectarlo al suministro de energ a el ctrica A ADVERTENCIA Peligro de incendio La tensi n de suministro debe encontrarse dentro de 10 de la tensi n de la placa de f brica Una tensi n incorrecta puede causar incendios o da ar al motor anulando la garant a Si est en du
22. tance from the work areas 44 WARNING Risk of explosion Pump body may explode if used as a booster pump unless relief valve capable of passing full pump flow at 75 psi is installed A WARNING Hazardous pressure Install pressure relief valve in discharge pipe ES ES Release all pressure on system before working on any component Warranty 3 Retain Original Receipt For Warranty Eligibility Limited Warranty This Limited Warranty is effective December 1 2011 and replaces all undated warranties and warranties dated before December 1 2011 CountyLine warrants to the original consumer purchaser Purchaser or You that its products are free from defects in material and workmanship for a period of twelve 12 months from the date of the original consumer purchase If within twelve 12 months from the original consumer purchase any such product shall prove to be defective it shall be repaired or replaced at CountyLine s option subject to the terms and conditions set forth herein Note that this limited warranty applies to manufacturing defects only and not to ordinary wear and tear All mechanical devices need periodic parts and service to perform well This limited warranty does not cover repair when normal use has exhausted the life of a part or the equipment The original purchase receipt and product warranty information label are required to determine warranty eligibility Eligib
23. tes de seguridad Guarde estas instrucciones Este manual contiene instrucciones importantes que se deben seguir durante la instalaci n y el mantenimiento del bombas de sumidero A Este es un s mbolo de alerta sobre la seguridad Cuando vea este s mbolo en su bomba o en este manual busque para ver si hay alguna de las siguientes palabras de se al y est alerta a la posibilidad de lesiones personales indica un riesgo que de no evitarse provocar la muerte o lesiones de gravedad A ADVERTENCIA indica un riesgo que de no evitarse podr a provocar la muerte o lesiones de gravedad A PRECAUCI N indica un riesgo que de no evitarse podria provocar lesiones leves o moderadas AVISO hace referencia a una pr ctica no relacionada con una lesi n f sica Lea y siga cuidadosamente todas las instrucciones de seguridad en este manual y en la bomba Mantenga las etiquetas de seguridad en buenas condiciones Reemplace las etiquetas de seguridad faltantes o da adas Conecte el motor al voltaje correcto Vea la secci n Electricidad en este manual y la placa del motor ADVERTENCIA lt Conecte el motor a tierra antes de conectarlo a la alimentaci n de energ a Voltaje peligroso Puede A Cumpla con las Pi ocasionar conmoci n indicaciones del C digo quemaduras e incluso Nacional El ctrico el de SR Canad y los c digos locales para toda la conexi n el ctrica Conecte la bomba
24. to the Twelve 12 Month Limited Warranty Product Warranty Period CL106 CL108 90 days CLTS33P CLSU14 2 Years CLVS50C CLW750 Pressure Tanks 5 Years General Terms and Conditions Limitation of Remedies You must pay all labor and shipping charges necessary to replace product covered by this warranty This warranty does not apply to the following 1 acts of God 2 products which in CountyLine s sole judgement have been subject to negligence abuse accident misapplication tampering or alteration 3 failures due to improper installation operation maintenance or storage 4 atypical or unapproved application use or service 5 failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums This warranty sets forth CountyLine s sole obligation and purchaser s exclusive remedy for defective products COUNTYLINE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above limitations or exclu
25. vida til de una pieza o del aparato Es necesario retener el recibo de compra original y la etiqueta de informaci n de la garant a a fin de determinar la elegibilidad para la garant a La elegibilidad se basa en la fecha de compra del producto original no en la fecha del reemplazo bajo la garant a La garant a es limitada y cubre solamente la reparaci n o el reemplazo del producto original adquirido no del producto reemplazado es decir que se permite un reemplazo por compra bajo la garant a El comprador pagar todos los costos de remoci n instalaci n mano de obra y env o necesarios as como todo costo adicional asociado Si necesita piezas o resoluci n de problemas NO regrese el producto a la tienda minorista Llame el Servicio a la Clientela de CountyLine al 1 800 535 4950 Las reclamaciones hechas bajo esta garant a se realizar n mediante la devoluci n del producto a excepci n de las bombas cloacales ver a continuaci n al concesionario de venta al p blico en donde se haya adquirido o a la f brica inmediatamente despu s de haber descubierto cualquier presunto defecto CountyLine entonces tomar la medida correctiva tan pronto como sea razonablemente posible No se aceptar n solicitudes de servicio si se reciben m s de 30 d as despu s del vencimiento de esta garant a La garant a no es transferible y no cubre productos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bom