Home
RLD382P - General Tools And Instruments
Contents
1. RLD382P Manual ee 7 10 08 dl AM 1 RLD382P USER S MANUAL Thank you for purchasing this Refrigerant Leak Detector Read through the instruction manual before operation for correct and safe usage Please store and retain this instruction manual for future reference ii RLD382P Manual re j 7 10 08 dl AM 1 FEATURES This Refrigerant Leak Detector is the perfect tool for maintaining air conditioning or cooling systems with a compressor and refrigerant This unit uses a newly developed semi conductor sensor which is extremely sensitive to a wide variety of general refrigerants Microprocessor control with advanced digital signal processing e Multi color visual display e High Medium Low leak sensitivity selector e Low battery indication e Semiconductor gas sensor e Detection of R 134a R 404A R 410A R 407C R 22 Freon gas e Carrying case included e 15 5 Flexible stainless probe 394mm e Reference leak source included e Ambient concentration reset e Long Life DC Brushless fan Automatic Zero and background compensation SPECIFICATIONS DETECTABLE GASES e R 134a R 404A R 410A R 407C R 22 Freon gas SENSITIVITY Hi Med Lo 134a R 22 3g year 15g year 30g year R 404A 407C 410A Ag year 20g year 40g year ALARM METHOD Buzzer Tricolor LED bar Indicator POWER SOURCE 4 AA batteries FLEXIBLE PROBE LENGTH 15 5 394mm DIMENSION WEIGHT 6 8 Hx 2 6 W x 2 2 D 173 x 66 x 5
2. into the sensor tip will affect the air flow over the sensor and cause the instrument to alarm 1 POWER UP KEY The ON OFF key turns the Refrigerant Leak Detector instrument ON or OFF and is also the reset function e Press it once to turn on the Refrigerant Leak Detector The display will illuminate with flashing for 45 seconds to heat up the sensor Press and hold this button for 5 seconds to turn OFF the power 2 AUTO RESET amp RESET FUNCTION KEY When the Auto Reset function is turned ON the meter will monitor background status and fine tune itself When Reset LED light is on it indicates it is in ON mode Press Reset button and hold for 2 seconds the Reset light will turn off and Auto Reset function is in OFF mode When the Reset light is off it indicates the Reset function is in manual mode Press the Reset button once to enable manual Reset function 3 VERIFY THE CONDITION OF THE UNIT AND SENSOR e Set the sensitivity level to Hi Open the Leak Check bottle cover and slowly move it closer to the flexible stainless probe nozzle e The indication should move up to high from low Then move the check bottle away and the LED should go off again This shows that the unit is in working condition e If the unit does not perform as expected order a new sensor and batteries from your local supply office 4 ENTER THE MEASURING MODE e Place the tip of the leak detector probe as close as possible to the site of
3. Indication More Highest Concentration Indication GETTING STARTED INSTALLING BATTERIES e Loosen the screw and remove the battery compartment door located on the bottom of the instrument as shown below Fig 1 e Install 4 AA batteries e Reinstall the battery cover by aligning it with the handle When the batteries are nearing the end of their useful life the Red LED Low Battery indicator will illuminate The batteries should be replaced as quickly as possible 4 AA batteries RLD382P Manual re j 7 10 08 dl AM 1 AUTOMATIC AMBIENT RESET FEATURE The Refrigerant leak detector features an Automatic Ambient Reset function that sets the unit to ignore ambient concentrations of refrigerant e Automatic Ambient Setup Upon initial power on the unit automatically sets itself to ignore the level of refrigerant present at the tip Only a level or concentration greater than this will cause an alarm CAUTION Be aware that this feature will cause the unit to ignore any refrigerant present at turn on In other words with the unit off if you place the tip up to a known leak and switch the unit on no leak will be indicated e Ambient Reset Feature Resetting the unit during operation performs a similar function it programs the circuit to ignore the level of refrigerant present at the tip This allows the user to home in on the source of the leak higher concentration Similarly the unit can be moved t
4. d air sur le capteur et peut d clencher alarme de l appareil 1 TOUCHE D ALIMENTATION La touche ON OFF commande la mise en marche et d arr t du d tecteur de fuite de r frig rant ainsi que la fonction de r initialisation e Appuyer une fois pour mettre le d tecteur de fuite de r frig rant en marche Lafficheur clignote pendant 45 seconds et demi durant le pr chauffage du capteur e Tenir la touche enfonc e pendant 5 secondes pour teindre l appareil 2 TOUCHE DE R INITIALISATION AUTOMATIQUE ET DE REINITIALISATION Lorsque la fonction de r initialisation automatique est mise en marche l appareil de mesure va surveiller l tat de l arri re plan et s ajustera lui m me Lorsque la lumi re DEL de r initialisation est en marche ceci indique qu elle est en mode de fonctionnement Appuyez sur le bouton de r initialisation et tenez le enfonc pendant 2 secondes et la lumi re de r initialisation va se fermer et le mode de r initialisation automatique sera arr t Lorsque la lumi re de r initialisation est arr t e ceci indique que la fonction de r initialisation est en mode manuel Appuyez sur le bouton de r initialisation une fois afin d activer la fonction de r initialisation ii RLD382P Manual ee 7 10 08 sa AM 1 3 V RIFIER L TAT DE L APPAREIL ET DU CAPTEUR e R gler le niveau de sensibilit sur Hi e Ouvrir le capuchon du flacon de contr le de fuite et le rapprocher lentement
5. de l embout de la sonde flexible e L affichage doit passer du niveau faible au niveau lev Eloigner ensuite le flacon de contr le et l affichage doit revenir z ro Ceci montre que l appareil est en bon tat de marche e Si l appareil ne fonctionne pas comme pr vu commander un capteur neuf et des piles aupr s du fournisseur local 4 PASSER EN MODE DE MESURE e Placer l embout de la sonde de d tection de fuite aussi pr s que possible de l emplacement de la fuite suppos e Essayer de placer la sonde moins de 6 mm de la source de fuite potentielle e Passer lentement la sonde devant chaque point de fuite possible e Lorsque l appareil d tecte une source de fuite l alarme sonore se d clenche Par ailleurs les indicateurs visuels s allument de la gauche vers la droite les voyants verts puis les voyants orange et enfin les voyants rouges concentration la plus lev e mesure de augmentation de niveau pour indiquer que l appareil se rapproche de la Source e Lorsque l appareil signale une fuite loigner la sonde de la fuite pendant quelques instants puis la ramener pour rep rer l emplacement exact Si la fuite de r frig rant est importante r gler la sensibilit sur Lo pour faciliter la localisation exact de la fuite e Remettre la sensibilit sur Hi avant de rechercher d autres fuites e Une fois le contr le de fuites termin teindre l appareil et le ranger dans un endroit propre d
6. e Devuelva el interruptor de sensibilidad a Hi alto antes de buscar fugas adicionales e Cuando haya terminado de buscar fugas apague el instrumento y gu rdelo en un sitio limpio para proteger el detector de fugas de posibles da os C MO INSTALAR UN SENSOR NUEVO En condiciones de operaci n normales el sensor funcionar m s de un a o Sin embargo el sensor puede tener un periodo de operaci n limitado Exponer el sensor a altas densidades de refrigerante gt 30000 ppm acortar su ciclo de vida m s r pidamente Es importante asegurarse de que la superficie del sensor no tenga gotas de agua vapor aceite grasa polvo o cualquier otra forma de contaminaci n Adem s para garantizar un buen funcionamiento de la unidad se debe reemplazar el sensor cuando termine su vida Util ADVERTENCIA Cuando instale un sensor nuevo puede que el sensor usado est CALIENTE 1 Retire la cubierta de la tapa c nica de la punta de la sonda flexible 2 Retire el sensor viejo e inserte el sensor nuevo en el enchufe ver figura 2 abajo 3 Selle la cubierta de la tapa sobre el enchufe ii RLD382P Manual E i 7 10 08 dl AM 1 Protector del sensor LIMPIEZA La caja de pl stico del instrumento se puede limpiar con detergente dom stico est ndar o con alcohol isoprop lico Se deber tener cuidado para evitar que el limpiador entre al instrumento La gasolina y otros disolventes pueden da ar el pl stico por
7. ignorer les concentrations ambiantes de r frig rant e Configuration de la fonction ambiante automatique Lors de la mise sous tension l appareil se r gle automatiquement pour ignorer la concentration en r frig rant au niveau de l embout Seul une teneur ou concentration plus lev e d clenchera une alarme ATTENTION Garder l esprit que cette fonction am ne l appareil ignorer tout r frig rant pr sent la mise sous tension En d autres termes si l embout de l appareil teint est plac c t d une fuite connue puis que l appareil est mis en marche aucune fuite ne sera signal e e Fonction de r initialisation ambiante La r initialisation de l appareil durant la marche remplit une fonction semblable en programmant le syst me pour qu il ignore la concentration de r frig rant pr sente au niveau de l embout Ceci permet de se diriger progressivement jusqu la source de la fuite concentration plus lev e Pareillement l appareil peut tre amen Vair frais et r initialis pour offrir une sensibilit maximum La r initialisation de l appareil en l absence de tout r frig rant air frais permet la d tection de toute concentration au dessus de z ro e Apr s que l unit soit r chauff e le niveau de sensibilit par d faut est r gl Elev et la fonction de r initialisation automatique est en marche e La fonction de r initialisation automatique est utilis e init
8. lo tanto se deber n evitar ADVERTENCIA El detergente o el alcohol isoprop lico pueden da ar el sensor Evite en todo momento el contacto con el sensor RLD382P Manual E j 7 10 08 dl AM 1 RLD380L MODE D EMPLOI D TECTEUR DE FUITE DE FLUIDE FRIGORIG NE AVEC POMPE G N RALIT S Merci d avoir achet ce d tecteur de fuite de r frig rant Pour assurer un usage correct et sans danger lire tout le mode d emploi avant utilisation Veiller conserver ce manuel pour toute consultation ult rieure FONCTIONS Ce d tecteur de fuite de r frig rant est l outil id al pour l entretien de syst mes de climatisation ou de r frig ration compresseur et fluide r frig rant Cet appareil comporte un capteur semi conducteur de conception nouvelle qui est extr mement sensible une grande vari t de fluides r frig rants courants e Commande par microprocesseur avec traitement de signal num rique volu e Affichage visuel couleur e S lecteur de sensibilit aux fuites lev moyen ou faible e Indication de d charge des piles Capteur de gaz semi conducteur e D tection de R 134a R 404A R 410A R 407C R 22 Fr on gazeux e Fourni avec tui de transport e Sonde inoxydable souple de 394mm 15 5 po e Fourni avec une source de fuite de r f rence e R initialisation de la concentration ambiante e Ventilateur sans balai CD de longue dur e e Z ro automatique et compensation de l arri
9. n mayor De manera semejante la unidad se puede mover a un sitio con aire fresco y restablecerse ah para lograr la m xima sensibilidad Al restablecer la unidad sin que haya refrigerante presente aire fresco hace que se detecte cualquier nivel por encima de cero e Luego de que la unidad se haya calentado el nivel inicial de sensibilidad ser High alto y la funci n de reinicio autom tico estar activada e La funci n de reinicio autom tico se aprovecha mejor al principio cuando el usuario se mueve tratando de identificar el origen de la p rdida Una vez que se haya determinado el origen de la p rdida desactive la funci n de detecci n autom tica y proceda con la medici n de la p rdida e La funci n de reinicio autom tico debe desactivarse al usarlo en una posici n fija para detectar p rdidas FUNCI N DE AJUSTE DE SENSIBILIDAD El instrumento ofrece dos niveles de sensibilidad Cuando la unidad se enciende se ajusta al nivel de sensibilidad alto e Para cambiar la sensibilidad oprima la tecla Lo bajo Cuando se oprime esta tecla se encender n moment neamente los dos LED de la izquierda verdes indicando que se seleccion el nivel de sensibilidad bajo e Para volver a la sensibilidad alta oprima la tecla Hi alto Los dos LED de la derecha rojos se encender n moment neamente para indicar que se seleccion el nivel de sensibilidad alto ii RLD382P Manual E j 7 10 08 il AM 1
10. periodically when it s operative life is over WARNING When replacing a new sensor the worn out sensor may be HOT 1 Remove cone cap cover from the tip of flexible probe 2 Pull out the old sensor and insert the new sensor into the plug see below fig 2 3 Seal the cap cover over the plug ensor Protector Sensor CLEANING The instruments plastic housing can be cleaned with standard household detergent or isopropyl alcohol Care should be taken to prevent the cleaner from entering the instrument Gasoline and other solvents may damage the plastic and should be avoided WARNING Detergent or isopropyl alcohol may damage the sensor Please avoid contact with the sensor at all times a RLD382P Manual re j 7 10 08 dl AM 1 RLD382P MANUAL DEL PROPIETARIO DETECTOR DE PERDIDAS DE REFRIGERANTE CON BOMBA INFORMACI N GENERAL Gracias por comprar este detector de fugas de refrigerante Lea cuidadosamente el manual de instrucciones antes de la operaci n para lograr un uso seguro y correcto Guarde y conserve este manual de instrucciones para consultarlo en el futuro CARACTER STICAS Este detector de fugas de refrigerante es la herramienta perfecta para dar mantenimiento a sistemas de aire acondicionado o refrigeraci n con compresor y refrigerante La unidad usa un sensor semiconductor creado recientemente que es extremadamente sensible a una amplia variedad de refrigerantes de uso general e Control p
11. re plan CARACT RISTIQUES GAZ D TECTABLES e R 134a R 404A R 410A R 407C R 22 Fr on gazeux SENSIBILIT Haute Milieu Basse 134a R 22 3 g an 15 g an 30 g an R 404A 407C 410A 4 g an 20 g an 40 g an M THODE D ALARME Ronfleur indicateur voyants tricolores ALIMENTATION LECTRIQUE 4 piles de format AA 6 V DC Longueur de la sonde flexible 394mm 15 5 po DIMENSIONS POIDS HxLxP 173 mm x 66 mm x 56 mm 400 g environ ii RLD382P Manual ee 7 10 08 ACCESSOIRES 4 piles AA Mode d emploi flacon de contr le de fuite tui de transport AUTONOMIE DES PILES 7 heures d utilisation normale environ ARRET AUTO 10 minutes D SACTIVER LA FERMETURE AUTOMATIQUE Appuyez et tenez enfonc le bouton d alimentation Hi sur l instrument de mesure DUR E DE PR CHAUFFAGE 45 secondes environ TEMP RATURE ET HUMIDIT D EXPLOITATION 0 40 C 32 104 F lt 80 HR TEMP RATURE ET HUMIDIT D ENTREPOSAGE 10 60 C 14 140 F lt 70 HR ALTITUDE lt 2000 m GUIDE D UTILISATION 1 Le d tecteur de fuite de r frig rant n est pas con u ni quip pour tre antid flagrant Ne pas utiliser cet appareil dans un milieu contenant des gaz combustibles 2 Diverses conditions ambiantes peuvent causer des erreurs de mesure e Pr sence de polluants e Grande variation de temp rature e Pr sence de vent fort e Les solvants organiques vapeurs d ad
12. 6 mm Approximately 14 1 oz 400 g ACCESSORIES 4 AA batteries User Manual Leak Check bottle carry case BATTERY LIFE Approximately 7 hours normal use AUTO POWER OFF 10 minutes a RLD382P Manual ee 7 10 08 me AM 1 DISABLE AUTO POWER OFF Press and Hold Hi button then power on the meter Warm Up TIME Approximately 45 seconds Operating Temperature amp Humidity 32 to 104 F 0 to 40 C lt 80 RH STORAGE TEMPERATURE amp HUMIDITY 14 to 140 F 10 to 60 C lt 70 RH ALTITUDE lt 6500 2000m OPERATING GUIDE 1 The refrigerant leak detector unit is not equipped with anti explosive designs and measures Do not use this unit in the environment with any burnable gases 2 There are some environmental conditions that might cause error readings e Pollutant places e Large temperature variation e Places with high wind velocity e Organic solvent adhesive vapor fuel gas and vesicant will cause an abnormal response from the sensor Try to avoid environments affected by these substances e Places filled with too much Freon gas PARTS 8 CONTROLS PANEL DESCRIPTION 1 Sensor Protector 2 Sensor 3 LED Leak Indicators 4 Sensitivity Lo Button 5 Sensitivity Hi Button 6 Reset Button 7 Low Battery Indicator 8 Power ON OFF 9 Battery Cover 10 Battery Cover Screw RLD382P Manual E j 7 10 08 dl AM 1 LED LEAK INDICATOR DEFINITION Base Concentration
13. Nivel de sensibilidad bajo LED verde Nivel de sensibilidad medio LED naranja Nivel de sensibilidad alto LED rojo PROCEDIMIENTO DE OPERACI N ADVERTENCIA No opere este instrumento en presencia de gasolina gas natural propano u otras atm sferas combustibles e C MO ENCONTRAR FUGAS NOTA Si se hace un movimiento repentino de la sonda del detector de fugas o se sopla en la punta del sensor se alterar el flujo de aire sobre el sensor y provocar que el instrumento emita una alarma 1 TECLA DE ENCENDIDO La tecla ON OFF enciende o apaga el detector de fugas de refrigerante y es tambi n la funci n de restablecimiento e Oprimala una vez para encender el detector de fugas de refrigerante Los LED se encender n y destellar n durante 45 segundos y medio para calentar el sensor e Oprima y sostenga este bot n durante 5 segundos para apagar 2 TECLA DE REINICIO AUTOM TICO Y FUNCI N DE REINICIO Cuando se activa la funci n de reinicio autom tico el medidor comenzar a monitorear el estado de fondo y se ajustar autom ticamente para compensarlo Cuando el LED de reinicio est encendido indica que est activado Mantenga presionado el bot n de reinicio durante 2 segundos y la luz de reinicio se apagar indicando que la funci n de reinicio autom tico est desactivada Cuando la luz de reinicio est apagada indica que la funci n de reinicio se encuentra en modo manual Presione una vez
14. UMEDAD DE OPERACI N 32 a 104 F 0 a 40 C lt 80 HR TEMPERATURA Y HUMEDAD DE ALMACENAMIENTO 14 a 140 F 10 a 60 C lt 70 HR ALTURA SOBRE EL NIVEL DEL MAR lt 6500 pies 2000 m GU A DE OPERACI N 1 La unidad del detector de fugas de refrigerante no est equipada con dise os y medidas contra explosi n No use esta unidad si en el ambiente hay gases combustibles 2 Hay ciertas condiciones ambientales que podr an causar lecturas err neas e Lugares con contaminantes e Grandes variaciones de temperatura e Lugares con alta velocidad del viento e Los disolventes org nicos el vapor adhesivo el gas combustible y los agentes vesicantes causar n una respuesta anormal del sensor Trate de evitar los entornos afectados por estas sustancias e Lugares llenos con exceso de gas fre n n PIEZAS Y CONTROLES E DIBUJOS Y CONTROL DESCRIPCI N DEL PANEL 1 Protector del sensor 2 Sensor 3 LEDs indicadores de p rdida 4 Bot n de sensibilidad baja 5 Bot n de sensibilidad alta 6 Bot n de reajuste 7 Indicador de pila baja 8 Bot n de ENCENDIDO APAGADO 9 Cubierta para las pilas 10 Tornillo para la cubierta de las pilas ii RLD382P Manual E j 7 10 08 dl AM 1 DEFINICI N DEL INDICADOR LED DE FUGA Indicaci n de concentraci n Indicaci n de concentraci n m s alta PARA EMPEZAR C MO INSTALAR LAS PILAS e Afloje el tornillo y retire la pu
15. e mani re prot ger le d tecteur contre les dommages potentiels REMPLACEMENT DU CAPTEUR NEUF Dans des conditions normales d utilisation le capteur doit fonctionner pendant plus d un an Toutefois il est possible que sa dur e utile soit plus limit e L exposition du capteur de fortes densit s de r frig rant gt 30000 ppm r duit rapidement sa dur e utile II est important de s assurer que la surface du capteur soit exempte de gouttelettes d eau vapeur huile graisse poussi re et autres contaminants De plus pour assurer un bon tat de marche de l appareil le capteur doit tre chang r guli rement l expiration de sa dur e utile ii RLD382P Manual re j 7 10 08 dl AM 1 AVERTISSEMENT Lors du remplacement du capteur neuf le capteur usag peut tre CHAUD 1 D poser le capuchon conique de embout de la sonde flexible 2 Extraire le capteur usag et introduire le capteur neuf dans la fiche voir Fig 2 ci dessous 3 Remettre le capuchon sur l embout Prot ge capteur NETTOYAGE Le bo tier en plastique de cet appareil se nettoie avec un d tergent m nager courant ou avec de l alcool isopropylique Prendre soin de ne pas laisser de produit nettoyant p n trer dans l appareil Lessence et autres solvants peuvent endommager le plastique et doivent tre vit s AVERTISSEMENT Les d tergents et l alcool isopropylique peuvent endommager le capteur Veiller viter to
16. el bot n de reinicio para activar la funci n de reinicio manual ii RLD382P Manual E j 7 10 08 dl AM 1 3 VERIFIQUE EL ESTADO DE LA UNIDAD Y DEL SENSOR e Ajuste el nivel de sensibilidad a Hi Alto e Destape la botella de comprobaci n de fugas y ac rquela lentamente a la boquilla de la sonda de acero inoxidable e La indicaci n deber subir de bajo a alto Luego aleje la botella de comprobaci n y el LED deber volver a apagarse Esto demuestra que la unidad est funcionando e Si la unidad no est funcionando de forma esperada pida a su proveedor local un nuevo sensor y pilas 4 ENTRE AL MODO DE MEDICI N e Ponga la punta de la sonda detectora de fugas tan cerca como sea posible de la posible fuga Trate de colocar la sonda a menos de 1 4 6 mm de la posible fuente de fuga e Mueva lentamente la sonda junto a cada posible punto de fuga e Cuando el instrumento detecte una fuente de fuga sonar una alarma Adem s los indicadores visuales se encender n de izquierda a derecha el LED verde luego el naranja despu s el rojo concentraci n m s alta ya que un aumento en el nivel indica la cercan a a la fuente e Cuando el instrumento indique una fuga retire la sonda de la fuga un momento y luego devu lvala para encontrar la ubicaci n exacta Si la fuga de refrigerante es grande mover el interruptor de sensibilidad a Lo bajo har que sea m s f cil encontrar el sitio exacto de la fuga
17. erta del compartimiento de las pilas ubicado en la parte inferior del instrumento como se muestra a continuaci n figura 1 e Instale 4 pilas AA e Vuelva a instalar la cubierta de las pilas y alin ela con el mango Cuando las pilas se est n acercando al final de su vida til el LED rojo que funciona como Indicador de pila baja se iluminar Se deber reemplazar las pilas tan pronto como sea posible RLD382P Manual re j 7 10 08 dl AM 1 FUNCI N DE RESTABLECIMIENTO AMBIENTAL AUTOM TICO El detector de fugas de refrigerante presenta una funci n de restablecimiento ambiental autom tico que ajusta la unidad para que ignore las concentraciones ambientales de refrigerante e Ajuste ambiental autom tico Al encender el detector la unidad se ajusta autom ticamente para ignorar el nivel de refrigerante presente en la punta S lo un nivel o concentraci n mayor desencadenar n una alarma PRECAUCI N Tenga en mente que esta funci n har que la unidad ignore el refrigerante presente al encenderse En otras palabras con la unidad apagada si se acerca la punta a una fuga conocida y se enciende el interruptor no se indicar una fuga e Funci n de restablecimiento ambiental Restablecer la unidad mientras est funcionado ejecuta una funci n similar programa el circuito para ignorar el nivel de refrigerante presente en la punta Esto permite al usuario encontrar m s f cilmente la fuente de la fuga una concentraci
18. h sif carburants gazeux et v sicants produisent une r ponse anormale du capteur Veiller viter les milieux pr sentant de telles substances e Milieux pr sentant une teneur lev e en Fr on gazeux PI CES ET COMMANDES h A DESCRIPTION DE LA FACADE 1 Prot ge capteur 2 Capteur 3 Indicateurs de fuite DEL 4 Bouton basse sensibilit 5 Bouton haute sensibilit 6 Bouton de remise 7 Indicateur de d charge des piles 8 Bouton de marche arr t 9 Couvercle des piles 10 Vis du couvercle des piles me AM RLD382P Manual ee 7 10 08 dl AM 1 INDICATIONS DES VOYANTS DE FUITE Indication de la concentration de base mu Pl us Y Indication de la concentration la plus lev e POUR D MARRER MISE EN PLACE DES PILES e Desserrer la vis et enlever le couvercle du compartiment des piles situ au bas de l appareil comme repr sent ci dessous Fig 1 e Placer 4 piles AA e Remettre le couvercle des piles en place en l alignant avec la poign e Lorsque les piles arrivent la fin de leur dur e utile le voyant de d charge des piles rouge s allume Les piles doivent alors tre chang es dans les plus brefs d lais RLD382P Manual E j 7 10 08 dl AM 1 FONCTION DE R INITIALISATION AMBIANTE AUTOMATIQUE Le d tecteur de fuite de r frig rant comporte une fonction de r initialisation ambiante automatique qui r gle l appareil de mani re
19. ialement lorsque l utilisateur se d place et tente de localiser la source de la fuite Une fois que la source de la fuite est d termin e annulez la fonction de r initialisation automatique afin de proc der la mesure de la fuite e La fonction de r initialisation automatique devrait tre arr t e lors de la d tection d une fuite un emplacement fixe R GLAGE DE LA SENSIBILIT Cet appareil offre deux niveaux de sensibilit la mise en marche il se r gle sur le niveau de sensibilit lev e Pour changer la sensibilit appuyer sur la touche Lo Lorsque cette touche est enfonc e les deux voyants de gauche verts s allument bri vement pour indiquer que la basse sensibilit est s lectionn e e Pour revenir la haute sensibilit appuyer sur la touche Hi Les deux voyants de droite rouges s allument bri vement pour indiquer que la haute sensibilit est s lectionn e ii RLD382P Manual E j 7 10 08 il AM 1 E Niveau de Se sibilit e LJ faible DEL verte Niveau de sensibilit moyen DEL orange Niveau de sensibilit lev DEL rouge PROCEDURE D UTILISATION AVERTISSEMENT Ne pas utiliser cet appareil en pr sence d essence de gaz naturel de propane ou autre atmosph re combustible COMMENT D TECTER DES FUITES REMARQUE Le fouettement soudain de la sonde de d tection de fuite ou le fait de souffler dans l embout du capteur modifie coulement
20. o fresh air and reset for maximum sensitivity Resetting the unit with no refrigerant present fresh air causes any level above zero to be detected e After the unit is warmed up the default sensitivity level is set at High and Auto Reset function is ON e Auto Reset function is best used initially when user is moving around trying to identify leakage source Once the leak source is determined cancel the Auto Detect function to proceed with leakage measurement e Auto Reset function should be turned OFF when use in fixed position leakage detection FEATURE SENSITIVITY ADJUSTMENT The instrument provides two levels of sensitivity When the unit is switched on it is set to the high sensitivity level e To change the sensitivity press the Lo key When this key is pressed the visual display will momentarily show the two left LED s green indicating low sensitivity level is selected e To switch back to high sensitivity press the Hi key The two right LED s red will light momentarily indicating high sensitivity level is selected Low Sensitivity Level Green LED Medium Sensitivity Level Orange LED High Sensitivity Level Red LED RLD382P Manual re j 7 10 08 OPERATING PROCEDURE WARNING Do not operate this instrument in the presence of gasoline natural gas propane or in other combustible atmospheres e HOW TO FIND LEAKS NOTE A sudden whipping of the leak detector probe or blowing
21. or microprocesador con procesamiento de se al digital e Visualizaci n a colores e Selector de sensibilidad de p rdida alta media baja e Indicaci n de pila baja Sensor de gas con semiconductor e Detecci n de R 134a R 404A R 410A R 407C R 22 gas fre n e Estuche incluido Sonda flexible de acero inoxidable de 394mm 15 5 e Se incluye fuente de fuga de referencia e Restablecimiento de concentraci n ambiental e Ventilador de CC sin escobillas de larga vida e Compensaci n autom tica de cero y de fondo ESPECIFICACIONES GASES DETECTABLES e R 134a R 404A R 410A R 407C R 22 gas fre n SENSIBILIDAD Alta Media Baja 134a R 22 3 g a o 15g a o 30 g a o R 404A 407C 410A 4 g a o 20g a o 40 g a o M TODO DE ALARMA Zumbador indicador de barra LED de tres colores CONSUMO DE ENERGIA 4 pilas tama o AA 6V CD Longitud de la sonda flexible 394mm 15 5 a RLD382P Manual re j 7 10 08 dl AM 1 DIMENSIONES PESO 6 8 alto x 2 6 ancho x 2 2 profundidad Aproximadamente 14 1 onzas 173 x 66 x 56 mm aproximadamente 400 g ACCESORIOS 4 pilas AA manual del usuario botella de comprobaci n de fugas estuche VIDA DE LA PILA Aproximadamente 7 horas de uso normal APAGADO AUTOM TICO 10 minutos DESACTIVACI N DEL APAGADO AUTOM TICO Mantenga presionado el bot n Hi cuando enciende el medidor TIEMPO DE CALENTAMIENTO Aproximadamente 45 segundos TEMPERATURA Y H
22. the suspected leak Try to position the probe within 1 4 6mm of the possible leak source Slowly move the probe past each possible leakage point e When the instrument detects a leak source the audible tone will alarm Additionally the visual indicators will light from left to right Green LED then Orange LED then Red LED highest concentration as increase in level indicates that the location is close to the source a dl AM RLD382P Manual E s j 7 10 08 il AM 1 e When the instrument signals a leakage pull the probe away from the leak for a moment then bring it back to pinpoint the location If the refrigerant leak is large setting the sensitivity switch to Lo will make it easier to find the exact site of the leak e Return the sensitivity switch to Hi before searching for additional leaks e When you ve finished leak testing turn OFF the instrument and store it in a clean place to protect the leak detector from possible damage REPLACING A NEW SENSOR Under normal operation the sensor should work for more than one year Though the sensor may experience a limited operative period Exposing the sensor to high densities of coolant gt 30000ppm will shorten its life cycle rapidly It is important to ensure that the sensor surface is free from water droplets vapor oil grease dust and any or all other forms of contaminant Furthermore to ensure good working condition of the unit a sensor must be replaced
23. ut contact avec le capteur RLD382P Manual a 7 10 08 dl AM 1 NOTES RLD382P Manual RER 7 10 08 dl AM 1 RLD382P Manual E ei 7 10 08 AM 1 Specialty Tools amp Instruments GENERAL TOOLS amp INSTRUMENTS 80 White Street New York NY 10013 3567 PHONE 212 431 6100 FAX 212 431 6499 TOLL FREE 800 697 8665 e mail sales generaltools com www generaltools com RLD382P User s Manual Specifications subject to change without notice 2008 GENERAL TOOLS amp INSTRUMENTS NOTICE WE ARE NOT RESPONSIBLE FOR TYPOGRAPHICAL ERRORS MAN RLD382P 7 08 ii
Download Pdf Manuals
Related Search
Related Contents
No.28(PDF:約3.7M) Kingston Technology HyperX Memory 1GB 500MHz DDR Non-ECC CL3 IT-Sicherheit im Deutschen Patent- und Markenamt Eureka 6900 SERIES Vacuum Cleaner User Manual Erratum p6 du manuel d`utilisation vous devriez lire Muvit MUCRF0018 mobile phone case InLine LC/ST 5m Copyright © All rights reserved.