1. 16 INTERVALOS DE SERVICIO 16 ESQUEMA DE LA PIEZAS 17 LISTA DE LAS PIEZAS 17 CUADRO DE DETECCI N DE FALLOS 22 23 TABLE OF CONTENTS TABLE DES MATI RES INDICE 200 2569 3 1 RISK OF FIRE OR EXPLOSION Never spray flammable liquids in a confined area It is normal for the motor and pressure switch to produce sparks while operating If sparks come into contact with vapors from gasoline or other solvents they may ignite causing fire or explosion Always operate the compressor in a well ventilated area Do not smoke while spraying Do not spray where sparks or flame are present Keep compressor as far from spray area as possible 2 RISK OF BURSTING Rust can weaken the tank Drain the condensed water from the tank after each use to reduce rusting If a leak is detected in the tank replace the tank immediately Do not weld drill or modify the air tank of this compressor Welding or modifications on the air compressor tank can severely impair tank strength and cause an extremely hazardous condition Welding or modifying the tank in any manner will void the warranty 3 RISK OF ELECTRICAL SHOCK A licensed electrician in accordance with all local and national codes must install all wiring Never use an electric air compressor outdoors when it
2. Tube Tubo 9 031 0081 1 Check valve Clapet de retenue V lvula de contraflujo 10 093 0068 1 Handle grip Poign e Empu adura 11 034 0176 1 Pressure switch Interrupteur Man metro 12 019 0228 1 Regulator R gulateur Regulador 13 032 0083 2 Pressure gauge Manom tre Man metro 14 136 0082 1 Safety valve Soupape V lvula 15 N A 1 Tank R servoir Tanque 16 094 0124 2 Vibration pad kit Tampon Almohadilla 17 072 0010 2 Petcock Robinet de d compression Llave de desag e 18 095 0049 2 Wheel Roue Rueda 19 026 0664 1 Power cord C ble
3. Cord n 20 032 0073 1 Oil level sight glass includes o rings Verre de vue de niveau d huile Cristal de la vista del nivel de aceite 21 043 0192 1 Valve plate assembly Ensemble de la plaque de soupape Conjunto de placa de v lvula includes gasket kit complete set inclut les Joints jeu complet incluye los Juntas conjunto completo 22 165 0273 1 Bushing kit Kit de douille Kit del buje includes 2 bushings and 4 screws inclut 2 douilles et 4 vis incluye 2 bujes y 4 tornillos 23 115 0311 1 Panel Panneau Panel 24 112 0128 1 Latch assembly Syst me verrouillage Montaje cerradura 25 041 0068 1 Connector block Bornier Bloque de conectador 26 012 0126 1 Air hose Tuyau flexible d air Manguera de aire 27 145 0464 1 Tube bleeder Tube Tubo 28 145 0465 1 Tube bleeder Tube Tubo 29 112 0129 1 Handle includes item 10
4. Poign e inclut les l ment 10 Maniga incluye los art culo 10 30 103 0142 1 Snap button Bouton instantan Bot n r pido 31 036 0031 3 Quick coupler Raccord rapide Acoplador r pido 18 200 2569 Note Troubleshooting problems may have similar causes and solutions Close petcock Tank petcock is open Check fittings with soapy water Tighten or reseal leaking fittings DO NOT OVERTIGHTEN Fittings Leak Clean or replace air filter element Restricted air intake Decrease amount of air used Prolonged excessive use of air Check air requirement of accessory If it is higher than CFM and pressure supplied by compressor you need a larger compressor Most accessories are rated at 25 of actual CFM while running continuously Compressor not large enough Remove and clean or replace Restricted check valve Check and replace if necessary Hole in air hose Immediately replace unit DO NOT attempt to repair Tank leaks Replace worn parts and reassemble Valve leaks Check fittings with soapy water Tighten or reseal leaking fittings DO NOT OVERTIGHTEN Fittings leak Replace worn parts and reassemble with new seals Replace regulator Dirty or damaged regulator internal parts If pressure drops too low adjust regulator while accessory is used This
5. 9 RISQUE D CLATEMENT Ne r glez jamais la soupape de d charge ou le manostat sous peine d entra ner l annulation de toutes les garanties Ces pi ces ont t pr r gl es en usine de mani re fournir la pression maximum La modification du manostat ou de la soupape de d charge peut entra ner des blessures ou des d g ts mat riels 10 RISQUE D CLATEMENT N utilisez pas de tuyaux en plastique ou en PVC pour l air comprim Utilisez uniquement des tuyaux et des raccords en acier galvanis pour le circuit de distribution de l air comprim 11 RISQUE AUDITIF Porter toujours des protecteurs d oreilles en utilisant un compresseur d air Dans le cas contraire il y a risque de perte d audition 12 RISQUE RESPIRATOIRE Ne jamais inhaler l air comprim d un compresseur Il ne convient pas la respiration 13 Le cordon de secteur sur ce produit contient le fil un produit chimique connu de l tat de la Californie pour causer le cancer et la naissance d serte ou l autre mal reproducteur Mains de lavage apr s manipulation 1 Vidangez tous les jours l humidit accumul e dans le r servoir Pour viter la corrosion le r servoir doit tre propre et sec 2 Tirez tous les jours sur l anneau de la soupape de d charge pour vous assurer qu elle fonctionne correctement et liminer toutes les obstructions possibles de la soupape 3 Pour assurer une ventilation correcte pour le refroidissemen
6. MODE D EMPLOI INSTRUCCIONES OPERATIVAS ARR T ARRANQUE DIARIO PARADA B OPEN OUVERT ABIERTO D CLOSE FERM SE CIERRAN E F 14 200 2569 To avoid personal injury always shut off and unplug the compressor and relieve all air pressure from the system before performing any service on the air compressor Regular maintenance will ensure trouble free operation Your electric powered air compressor represents high quality engineering and construction however even high quality machinery requires periodic maintenance The items listed below should be inspected on a regular basis Condensation will accumulate in the tank To prevent corrosion of the tank from the inside this moisture must be drained at the end of every workday Be sure to wear protective eyewear Relieve the air pressure in the system and open the petcock on the bottom of the tank to drain NOTE In cold climates drain the tank after each use to reduce problems with freezing of water condensation A dirty air filter will reduce the compressor s performance and life To avoid any internal contamination of the pump the filter should be cleaned frequently and replaced on a regular basis Foam filters should be cleaned in warm soapy water Do not allow the filter to become filled with dirt or paint Direct exposure to dirty conditions or painting areas will void your warranty Check the level of oil in the pump with the sight glass The pump
7. 12 200 2569 1 Every day check the sight glass to ensure that the level of oil in the pump is at the required level The pump oil level must be between X and Y see E Do not overfill or underfill 2 Turn the pressure switch to the OFF position see A 3 Close the tank petcock see D Turn in the clockwise direction 4 Plug in the power cord High temperatures are generated by the electric motor and the pump To prevent burns or other injuries DO NOT touch the compressor while it is running Allow it to cool before handling or servicing Keep children away from the compressor at all times 5 Turn the pressure switch to the ON position see C When adjusting from a higher to a lower pressure turn the knob counterclockwise past the desired setting then turn clockwise to reach the desired pressure Do not exceed operating pressure of the tool or accessory being used 6 If a pressure regulator is present on your compressor adjust it to the working pressure of the tool 1 Turn the pressure switch to the OFF position see A 2 Unplug the power cord 3 Reduce pressure in the tank through the outlet hose You can also pull the relief valve ring see F and keep it open to relieve pressure in the tank Escaping air and moisture can propel debris that may cause eye injury Wear safety goggles when opening petcock 4 Tip the compressor if necessary for your model so the petcock is at the bottom of the tank s
8. au niveau correct et v rifiez souvent le niveau De l huile tous temps de compresseur de l air 10W 30 est recommand e pour l usage g n ral 1 V rifiez le niveau d huile dans chaque pompe avec le viseur voir X et Y E Le niveau d huile de la pompe doit tre au rep re maximum sur le viseur Ne remplissez pas trop et remplissez suffisamment 2 Placer le manocontacteur en position ARR T A 3 Ouvrez le robinet de purge B Tourner le bouton vers la droite 4 Branchez le cordon d alimentation 5 Tourner le manocontacteur en position MARCHE C Le compresseur d marre Laissez tourner pendant 30 minutes pour roder les pi ces internes REMARQUE Si apr s 30 minutes l appareil ne fonctionne pas correctement ARRETEZ LE IMM DIATEMENT et contactez le service apr s vente 6 Apr s environ 30 minutes tourner le manocontacteur en position ARR T 7 Fermez le robinet de purge D 8 Tourner le manocontacteur en position MARCHE Tourner vers la droite Le compresseur d marre et remplit le r servoir jusqu la pression de fermeture puis s arr te REMARQUE Une fois que suffisamment d air comprim est utilis le manostat relance automatiquement le moteur LA BOMBA SE ENVIA SIN ACEITE Poner aceite en la bomba hasta la marca correcta y verificar el nivel con freduencia El aceite para cualquier estaci n del compresor de aire 10W 30 se recomienta para el uso general 1 Verifique el nivel de ac
9. la sortie d air du compresseur F derri re le panneau Pour utiliser le panneau sans d placer le compresseur tournez le bouton G de 1 4 de tour dans le sens horaire droite puis soulevez le panneau et retirez le D branchez le court boyau air reliant le panneau la sortie d air Raccordez l un des bouts d un boyau air non inclus la sortie d air du compresseur F et l autre bout au boyau amovible du panneau avant voir fig 2 D placez le panneau sur le lieu de travail et raccordez vos boyaux air aux raccords rapides H sur le devant du panneau Interruptor de presi n vea A Este interruptor enciende el compresor Se opera manualmente pero cuando est en la posici n ON permite que el compresor arranque o se pare autom ticamente sin aviso seg n la demanda de aire SIEMPRE coloque este interruptor en la posici n OFF cuando el compresor no est en uso y antes de desconectarlo V lvula de alivio de presi n vea B Si el interruptor de presi n no apaga el motor cuando la presi n alcanza el nivel de desconexi n esta v lvula se abrir autom ticamente para evitar una sobrepresi n Para accionarla manualmente tire del anillo en la v lvula de alivio de la presi n del aire en el tanque Man metro del tanque vea C Este man metro mide la presi n del aire almacenado en el tanque No es ajustable por el operador y no indica la presi n de la l nea Regulador de presi n de aire vea D El regula
10. NE 68848 EE UU PARTS AND SERVICE PI CES ET R PARATIONS REPUESTOS Y SERVICIO Manufactured in China for Fabriqu China pour Fabricado en China para Powermate Corporation Aurora IL 60504 2007 Powermate Corporation All Rights Reserved Tous droits r serv s Reservados todos los derechos
11. Si le moteur surchauffe le limiteur coupe l alimentation pour viter d endommager le moteur Lorsque le moteur est suffisamment refroidi il red marre automatiquement La pompe B comprime l air Le r servoir C contient l air comprim Le manostat D arr te le moteur et lib re la pression d air dans la pompe et le tube de transfert quand la pression dans le r servoir atteint la pression de fermeture Au fur et mesure que l air comprim est utilis et que le niveau de pression dans le r servoir baisse jusqu la pression d ouverture le manostat remet le moteur en marche automatiquement sans avertissement et la pompe reprend la compression d air Le panneau amovible voir E permet la mobilit des commandes du compresseur sans avoir le d placer La poign e escamotable voir F peut tre allong e pour d placer le compresseur et r tract e pour un rangement moins encombrant Los componentes b sicos del compresor de aire son el motor el ctrico la bomba el interruptor de presi n y el tanque El motor el ctrico vea A acciona la bomba El motor el ctrico est equipado con un protector contra sobrecargas y un reajuste autom tico Si el motor se sobrecalienta el protector contra sobrecargas lo apagar para evitar que sufra da os Cuando el motor se enfr e lo suficiente volver a arrancar autom ticamente La bomba vea B comprime el aire y lo descarga hacia el tanque El tanque vea C almacena el
12. n a tierra con su enchufe correspondiente El enchufe debe conectarse en un tomacorriente que est bien instalado y conectado a tierra de acuerdo con todos los c digos y ordenanzas locales La instalaci n incorrecta del enchufe de conexi n a tierra puede causar un riesgo de descarga el ctrica En caso de ser necesario reparar o cambiar el cord n o el enchufe no conecte el alambre de conexi n a tierra en ninguno de las terminales de pata plana El alambre de conexi n a tierra tiene aislamiento de color verde con rayas amarillas o sin ellas Este producto se debe usar en un circuito de 115 voltios nominales Se deber usar un enchufe con un terminal conectado a tierra tal como el mostrado aqu Aseg rese de que el producto est conectado a un tomacorriente que tenga la misma configuraci n que el enchufe V ase la Figura 1 No debe usarse ning n adaptador con este producto Consulte con un electricista capacitado si no comprende completamente las instrucciones de conexi n a tierra o si tiene dudas con respecto a si el producto est correctamente conectado a tierra No modifique el enchufe provisto si no encaja en el tomacorriente haga que un electricista capacitado instale un tomacorriente adecuado PELIGRO Bo te prises de terre Caja de tomacorriente puesta a tierra Prise de courant mise la terre Tomacorriente puesta a tierra Fiche Tap n Broche de terre Pasador de puesta a tierra 115 VOLTS 1
13. presi n del sistema antes de realizar el servicio al compresor y cuando el compresor no est en uso No utilice la unidad sin las cubiertas o sin el protector de la correa ya que podr a sufrir lesiones por el contacto con las piezas m viles 5 RIESGO DE EXPLOSI N Verifique la presi n nominal m xima sugerida por el fabricante para las herramientas y los accesorios neum ticos La presi n de salida del compresor se debe regular de tal manera que nunca se exceda la presi n nominal m xima de la herramienta Antes de conectar o retirar accesorios alivie toda presi n del tubo 6 RIESGO DE QUEMADURAS La bomba y el m ltiple producen altas temperaturas Para prevenir quemaduras u otro tipo de heridas NO TOQUE la bomba el m ltiple ni el tubo de transferencia mientras la bomba se est funcionando Permita que se enfr e antes de manipularlos o realizar el servicio necesario Mantenga a los ni os alejados del compresor en todo momento 7 RIESGO PARA LA RESPIRACI N Aseg rese de leer todas las etiquetas cuando est rociando pinturas o materiales t xicos y siga las instrucciones de seguridad Use una careta respiratoria si existe la posibilidad de inhalar alg n producto al rociar Lea todas las instrucciones y aseg rese de que su careta respiratoria le proteja 8 RIESGO DE LESIONES OCULARES Cuando utilice un compresor de aire siempre use gafas de seguridad aprobadas seg n ANSI Z87 1 Nunca dirija la boquilla ni el
14. Then open the petcocks see B to allow moisture to drain from the tank 1 V rifiez le niveau d huile dans chaque pompe avec le viseur voir X et Y E Le niveau d huile de la pompe doit tre au rep re maximum sur le viseur Ne remplissez pas trop et remplissez suffisamment 2 Placer le manocontacteur en position ARR T A 3 Fermez le robinet de purge du r servoir D Tourner vers la droite 4 Branchez le cordon d alimentation La pompe et le moteur lectrique produisent des temp ratures lev es Pour viter les br lures et autres blessures NE touchez PAS le compresseur quand il est en marche Laissez le refroidir avant de le manipuler ou d effectuer son entretien Ne laissez jamais les enfants s approcher du compresseur 5 Tourner le manocontacteur en position MARCHE C Pour passer d une pression lev e une pression plus basse tournez le bouton dans le sens contraire des aiguilles d une montre au del du r glage de pression d sir puis tournez le dans le sens des aiguilles d une montre pour atteindre la pression d sir e Ne pas d passer la pression de fonctionnement de l outil ou de l accessoire utilis 6 Si votre compresseur est quip d un r gulateur de pression r glez sa pression pour qu elle corresponde la pression de service de l outil WARNING WARNING CAUTION AVERTISSEMENT OPERATING INSTRUCTIONS MODE D EMPLOI INSTRUCCIONES OPERATIV
15. ces en mouvement 5 RISQUE D CLATEMENT V rifiez les sp cifications de pression maximum recommand es par le fabricant pour les outils et les accessoires pneumatiques La pression de sortie du compresseur doit tre r gl e de fa on ne jamais d passer la pression maximum nominale de l outil D pressurisez enti rement le tuyau avant de raccorder ou de d brancher des accessoires 6 RISQUE DE BR LURE Les temp ratures lev es sont produites par la pompe et la tubulure Pour viter toute br lure ou d autres blessures NE TOUCHEZ PAS la pompe le distributeur ou le tube de transfert tandis que la pompe fonctionne Laissez les refroidir avant de les manipuler ou de proc der leur entretien Ne laissez jamais les enfants s approcher du compresseur 7 RISQUE RESPIRATOIRE Veillez lire toutes les tiquettes quand vous pulv risez de la peinture ou des mat riaux toxiques et suivez les consignes de s curit Utilisez un masque gaz si vous risquez d inhaler le produit pulv ris Lisez toutes les instructions et veillez ce que le masque gaz assure votre protection 8 RISQUE DE BLESSURE AUX YEUX Porter toujours des lunettes de s curit homologu es ANSI Z87 1 lors de l utilisation d un compresseur d air Ne dirigez jamais une buse ou un pulv risateur vers quelqu un ou une quelconque partie du corps Ce mat riel peut causer des blessures graves si le produit vaporis p n tre dans la peau
16. de la pompe Toutes les 100 heures de fonctionnement Faites fonctionner les soupapes de d charge Chaque jour Vidangez le r servoir Chaque jour V rifiez et serrez tous les boulons Toutes les 100 heures de fonctionnement Ne les serrez pas trop A Oil drain plug Bouchon Tap n B Oil level sight glass Verre de vue de niveau d huile Cristal de la vista del nivel de aceite C Oil fill plug Bouchon de l orifice de remplissage d huile Tapon de llenado de aceite X Full Plein Lleno Y Add Ajoutez Agregar 16 200 2569 MANTENIMIENTO Para evitar lesiones personales siempre apague y desenchufe el compresor y alivie toda la presi n de aire del sistema antes de realizar alg n tipo de servicio en el compresor de aire El mantenimiento regular asegurar una operaci n sin problemas Su compresor de aire con alimentaci n el ctrica representa lo mejor en ingenier a y construcci n sin embargo a n la maquinaria de mejor calidad requiere un mantenimiento peri dico Los elementos enumerados a continuaci n deben inspeccionarse de manera regular La condensaci n se acumular en el tanque Para evitar la corrosi n del tanque desde el interior esta humedad debe ser drenada al final de cada d a de trabajo Aseg rese de utilizar protecci n ocular Alivie la presi n de aire en el sistema y abra la llave de descompresi n que se encuentra en el fondo del tanque para drenar NOTA En c
17. electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This product is equipped with a cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinance Improper installation of the grounding plug can result in a risk of electric shock If repair or replacement of the cord or plug is necessary do not connect the grounding wire to either flat blade terminal The wire insulation having an outer surface that is green with or without yellow stripes is the grounding wire This product is for use on a nominal 115 volt circuit A cord with a grounding plug as shown here shall be used Make sure that the product is connected to an outlet having the same configuration as the plug see Figure 1 No adapter should be used with this product Check with a licensed electrician if the grounding instructions are not completely understood or if in doubt as to whether the product is properly grounded Do not modify the plug provided if it will not fit the outlet have the proper outlet installed by a licensed electrician Pour vous renseigner sur les normes d intensit et de tension de l appareil r f rez vous l tiquette du num ro de s rie du compresseur d air Utilisez un circuit s par Pour obtenir le meilleur rendement possible et une mise
18. en marche fiable le compresseur d air doit tre install sur un circuit s par aussi pr s que possible d une bo te fusibles ou d un disjoncteur Le compresseur utilise toute la capacit d un circuit usage domestique typique Si d autres appareils lectriques tirent du courant sur le circuit du compresseur il est possible que le compresseur ne puisse pas d marrer Si la tension est insuffisante ou si le circuit est surcharg le d marrage risque d tre lent et d entra ner en cons quence le d clenchement du disjoncteur ou de l interrupteur de remise en marche du moteur surtout s il fait froid REMARQUE Il est recommand d utiliser un disjoncteur Si le compresseur est branch sur un circuit prot g par un fusible utilisez des fusibles temporis s double l ment Buss Fusetron de type T seulement REMARQUE vitez d utiliser des rallonges Pour obtenir un rendement optimum branchez le c ble d alimentation du compresseur directement sur une prise de courant mise la terre N utilisez pas de rallonge sauf n cessit absolue Utilisez plut t un tuyau flexible plus long pour atteindre la zone o l air est n cessaire S il l utilisation d une rallonge est in vitable le cordon lectrique ne doit pas d passer 15 m 50 pi et doit tre d un calibre minimum de 12 AWG N utilisez pas une rallonge de calibre 16 ou 14 Utilisez seulement une rallonge 3 fils munie d une prise de terre 3 lames et u
19. is raining or on a wet surface as it may cause an electric shock 4 RISK OF INJURY This unit starts automatically ALWAYS shut off the compressor remove the plug from the outlet and bleed all pressure from the system before servicing the compressor and when the compressor is not in use Do not use the unit with the shrouds or beltguard removed Serious injury could occur from contact with moving parts 5 RISK OF BURSTING Check the manufacturer s maximum pressure rating for air tools and accessories Compressor outlet pressure must be regulated so as to never exceed the maximum pressure rating of the tool Relieve all pressure through the hose before attaching or removing accessories 6 RISK OF BURNS High temperatures are generated by the pump and manifold To prevent burns or other injuries DO NOT touch the pump manifold or transfer tube while the pump is running Allow them to cool before handling or servicing Keep children away from the compressor at all times 7 RISK TO BREATHING Be certain to read all labels when you are spraying paints or toxic materials and follow the safety instructions Use a respirator mask if there is a chance of inhaling anything you are spraying Read all instructions and be sure that your respirator mask will protect you 8 RISK OF EYE INJURY Always wear ANSI Z87 1 approved safety goggles when using an air compressor Never point any nozzle or sprayer toward a person or any part o
20. o tuber a reducir de manera substancial el rendimiento de su compresor de aire Si sospecha la existencia de una fuga roc e una peque a cantidad de agua jabonosa alrededor de la zona con una botella rociadora Si aparecen burbujas selle y ajuste nuevamente la conexi n No ajuste demasiado Antes de almacenar el compresor durante per odos prolongados use un soplete de aire para limpiar todo el polvo y suciedad del compresor Desconecte el cord n el ctrico enroll ndolo Tire de la v lvula de alivio de la presi n para liberar toda la presi n del tanque Elimine toda la humedad del tanque Limpie los elementos y el alojamiento del filtro reempl celos si fuera necesario Cubra toda la unidad para protegerla de la humedad y del polvo ADVERTENCIA AVERTENCIA MANTENIMIENTO DESAG E DEL TANQUE LIMPIEZA DEL FILTRO DE AIRE VERIFICACI N DEL NIVEL DE ACEITE REVISI N DE LA V LVULA DE ALIVIO DETECCI N DE FUGAS ALMACENAMIENTO ENTRETIEN P RIDIQUE Realice el mantenimiento siguiente a los intervalos indicados a continuaci n Inspecci n y limpieza del filtro de aire de entrada A diario Verificaci n del nivel de aceite en la bomba A diario Cambio del aceite de la bomba Cada 100 horas de operaci n Operaci n de todas las v lvulas de alivio de la presi n A diario Drenaje del tanque A diario Verificaci n y ajuste de todos los pernos no ajuste demasiado Cada 100 horas de ope
21. oil level must be between X and Y Do not overfill or underfill NOTE 10W 30 All weather air compressor oil is recommended for general use Remove the oil plug see A and drain the oil until it slows to a drip then close Add compressor oil until it is between full see X and add see Y Never overfill or underfill the pump Pull the relief valve daily to ensure that it is operating properly and to clear the valve of any possible obstructions Check that all connections are tight A small leak in any of the hoses transfer tubes or pipe connections will substantially reduce the performance of your air compressor If you suspect a leak spray a small amount of soapy water around the area of the suspected leak with a spray bottle If bubbles appear repair or replace the faulty component Do not overtighten any connections Before storing the compressor for a prolonged period use an air blow gun to clean all dust and debris from the compressor Disconnect the power cord and coil it up Pull the pressure relief valve to release all pressure from the tank Drain all moisture from the tank Clean the filter element and filter housing replace the element if necessary Cover the entire unit to protect it from moisture and dust WARNING WARNING MAINTENANCE MAINTENANCE DRAINING THE TANK CLEANING THE AIR FILTER CHECKING THE OIL CHANGING THE OIL CHECKING THE RELIEF VALVE TESTING FOR LEAKS STORAGE SERVICE INTE
22. rociador hacia una persona ni hacia alguna parte del cuerpo El equipo puede causar una lesi n grave si el roc o penetra en la piel 9 RIESGO DE EXPLOSI N No intente ajustar el interruptor de presi n ni la v lvula de alivio por ninguna raz n Si lo hace anular todas las garant as Estas piezas se ajustaron en f brica para que permitan la presi n m xima de esta unidad Si se altera el interruptor de presi n o la v lvula de seguridad se puede ocasionar una lesi n personal y o da os materiales 10 RIESGO DE EXPLOSI N No use tuber a de pl stico ni de PVC para el sistema de aire comprimido Use s lo tuber a y conectores de acero galvanizado para las l neas de distribuci n de aire comprimido 11 RIESGO AL SENTIDO DEL O DO Siempre use protectores auditivos cuando use un compresor de aire Si no lo hace podr a sufrir p rdida de la audici n 12 RIESGO PARA LA RESPIRACI N Nunca inhale directamente el aire comprimido producido por un compresor No es adecuado para respirarly 13 El cable el ctrico en este producto contiene el plomo un producto qu mico sabido al estado de California para causar el c ncer y el nacimiento deserta o el otro da o reproductivo Manos de la colada despu s de dirigir ADVERTENCIA 1 Elimine la humedad del tanque todos los d as Un tanque limpio y seco ayudar a evitar la corrosi n 2 Tire del anillo de la v lvula de alivio de la presi n todos los d as para asegurar
23. 2 Daily Startup 12 Shutdown 12 MAINTENANCE 14 Draining the Tank 14 Cleaning the Air Filter 14 Checking the oil 14 Changing the oil 14 Checking the Relief Valve 14 Testing for Leaks 14 Storage 14 SERVICE INTERVAL 14 PARTS DRAWING 17 PARTS LIST 17 TROUBLESHOOTING CHART 18 19 CONSIGNES DE S CURIT 4 VUE D ENSEMBLE 6 l ments de base du compresseur d air 6 ASSEMBLAGE 7 Assemblage du compresseur 7 COMMANDES DU COMPRESSEUR 8 SP CIFICATIONS DE L ALIMENTAT
24. 200 2569 Revision B Operator Parts Manual Manuel de l op rateur Manuel de pi ces Manual del operador Manual de piezas Single Stage Direct Drive Oil Lubricated Electric Air Compressors D une seul tape prise directe graiss avec de l hule compresseurs d air lectriques De una sola etapa de mando directo Lubricado con aceite compresores de aire el ctricos WARNING Read and understand all safety precautions in this manual before operating Failure to comply with instructions in this manual could result in personal injury property damage and or voiding of your warranty The manufacturer WILL NOT be liable for any damage because of failure to follow these instructions AVERTISSEMENT Lisez et veillez bien comprendre toutes les consignes de s curit de ce manuel avant d utiliser l appareil Toute d rogation aux instructions contenues dans ce manuel peut entra ner l annulation de la garantie causer des blessures et ou des d g ts mat riels Le fabricant NE SAURA tre tenu responsable de dommages r sultant de l inobservation de ces instructions ADVERTENCIA Lea y comprenda todas las precauciones de seguridad contenidas en este manual antes de utilizar esta unidad Si no cumple con las instrucciones de este manual podr a ocasionar lesiones personales da os a la propiedad y o la anulaci n de su garant a El fabricante NO SER responsable de ning n da o por no acatar estas instrucciones Spec
25. 21 PAUTAS DE SEGURIDAD 5 RESUMEN GENERAL 6 Componentes b sicos del compresor de aire 6 MONTAJE 7 Montaje del compressor 7 CONTROLES DEL COMPRESOR 8 REQUERIMIENTOS DE ALIMENTACI N EL CTRICA 10 Cableado el ctrico 10 Cordones prolongadores 10 Instrucciones de conexi n a tierra 10 MARCHA INICIAL DEL BOMBA 11 INSTRUCCIONES OPERATIVAS 13 Arranque diario 13 Parada 13 MANTENIMIENTO 15 Desag e del tanque 16 Limpieza del filtro de aire 16 Verificaci n del nivel de acrite 16 Cambio de aceite 16 Revisi n de la v lvula de alivio 16 Detecci n de fugas 16 Almacenamiento
26. 5 AMP RES 115 VOLTIOS 15 AMPERIOS Figure 1_________Figura 1 DANGER INSTRUCTIONS DE MISE LA TERRE CABLEADO EL CTRICO SP CIFICATIONS DE L ALIMENTATION LECTRIQUE REQUERIMIENTOS DE ALIMENTACION ELECTRICA CORDONES PROLONGADORES INSTRUCCIONES DE CONEXI N A TIERRA 200 2569 11 PUMP SHIPPED WITHOUT OIL Fill pump to correct mark and check often SAE 10W 30 All weather air compressor oil is recommended for general use 1 Check the level of oil in the pump with the sight glass The pump oil level must be between X and Y see E Do not overfill or underfill 2 Turn the pressure switch to the OFF position see A 3 Open the petcock see B Turn in the counterclockwise direction 4 Plug in the power cord 5 Turn the pressure switch to the ON position see C The compressor will start Allow the compressor to run for 30 minutes to break in the internal parts NOTE After about 30 minutes If the unit does not operate properly SHUT DOWN IMMEDIATELY and contact Product Service 6 After about 30 minutes turn the pressure switch to the OFF position 7 Close the petcock see D Turn in the clockwise direction 8 Turn the pressure switch to the ON position The compressor will start and fill the tank to the kick out pressure and stop NOTE As compressed air is used the pressure switch will restart the motor automatically LA POMPE QUI EST EXP DI E NE CONTIENT PAS D HUILE Remplissez la pompe jusqu
27. AS DAILY STARTUP SHUTDOWN MISE EN MARCHE QUOTIDIENNE B OPEN OUVERT ABIERTO D CLOSE FERM SE CIERRAN E AVERTISSEMENT F 200 2569 13 1 Placer le manocontacteur en position ARR T A 2 D branchez le cordon d alimentation 3 R duisez la pression dans le r servoir par l orifice de sortie du tuyau Vous pouvez galement tirer sur l anneau de la soupape de d charge F et la maintenir ouverte pour lib rer la pression dans le r servoir L air et l humidit qui s chappent peuvent projeter des particules pouvant causer des blessures aux yeux Portez des lunettes de protection lorsque vous ouvrez le robinet de purge 4 Incliner l g rement le compresseur si cela est n cessaire pour votre mod le afin que le robinet soit en bas du des r servoirs Ouvrez le robinet voir B pour purger toute l humidit accumul e dans le r servoir 1 Todos los d as verifique la mirilla para aseguarse de que el nivel de aceite en cada bomba est al nivel reuerido El nivel de aceite en la bomba debe estar en la marca correspondiente a lleno en la mirilla de vifrio vea X y Y E No ponga demasiado ni muy poco aceite en la bomba 2 Coloque el conmutador activado por presi n en la posici n APAGADO vea A 3 Cierre la llave de descompresi n del tanque vea D H galo girar hacia la derecha 4 Enchufe el cord n el ctrico El motor el ctrico y la bomba producen altas temperaturas Para evi
28. ION LECTRIQUES 9 C blage lectrique 9 Rallonges 9 Instructions de mise la terre 10 RODAGE DE LA POMPE 11 MODE D EMPLOI 12 Mise en marche quotidienne 12 Arr t 13 ENTRETIEN 15 Vidange du r servoir 15 Nettoyage du filtre air 15 V rivication du niveau d huile 15 Vindage d huile 15 V rification de la soupape de d charge 15 Essai d tanch it 15 Entreposage 15 ENTRETIEN P RIODIQUE 15 DESSIN DES PI CES 17 LISTE DE PI CES 17 D PANNAGE 20
29. R LESIONES LEVES O DA AR EL EQUIPO ADVERTENCIA PELIGRO PRECAUCI N 6 200 2569 The basic components of the air compressor are the electric motor pump pressure switch and tank The electric motor see A powers the pump The electric motor is equipped with an overload protector and an automatic reset If the motor becomes overheated the overload protector will shut it down to prevent damage to the motor When the motor sufficiently cools it will automatically restart The pump see B compresses the air and discharges it into the tank The tank see C stores the compressed air The pressure switch see D shuts down the motor and relieves air pressure in the pump and transfer tube when the air pressure in the tank reaches the kick out pressure As compressed air is used and the pressure level in the tank drops to the kick in pressure the pressure switch restarts the motor automatically without warning and the pump resumes compressing air The removable panel see E allows mobility of the compressor controls without having to move the compressor The retractable handle see F can be pulled out for moving the compressor and pushed in to take up less room when storing Les l ments de base du compresseur d air sont le moteur lectrique la pompe le manostat et le r servoir Le moteur lectrique A actionne la pompe Le moteur lectrique est quip d un limiteur de surcharge r enclenchement automatique
30. RVAL Perform the following maintenance at the intervals indicated below Inspect and clean air filter Daily Check pump oil level Daily Change pump oil Every 100 operating hours Operate the pressure relief valves Daily Drain tank Daily Check and tighten all bolts Every 100 operating hours Do not overtighten A Oil drain plug Bouchon Tap n B Oil level sight glass Verre de vue de niveau d huile Cristal de la vista del nivel de aceite C Oil fill plug Bouchon de l orifice de remplissage d huile Tapon de llenado de aceite X Full Plein Lleno Y Add Ajoutez Agregar 200 2569 15 ENTRETIEN Pour viter les risques de blessures arr tez et d branchez toujours le compresseur et lib rez toute la pression d air dans le circuit avant de proc der l entretien L entretien r gulier de l appareil permettra d assurer un fonctionnement sans probl mes Votre compresseur d air lectrique est un appareil de haute qualit toutefois m me les machines de haute qualit n cessitent un entretien p riodique Les composants num r s ci dessous doivent tre inspect s r quli rement De la condensation se forme dans le r servoir Pour viter la formation de corrosion depuis l int rieur du r servoir cette condensation doit tre vacu e la fin de chaque journ e de travail Veillez porter des lunettes de protection Lib rez la pression d air dans le circuit et ouvre
31. UIPMENT WARNING DANGER CAUTION 1 Drain the moisture from the tank on a daily basis A clean dry tank will help prevent corrosion 2 Pull the pressure relief valve ring daily to ensure that the valve is functioning properly and to clear the valve of any possible obstructions 3 To provide proper ventilation for cooling the compressor must be kept a minimum of 12 inches 31 cm from the nearest wall in a well ventilated area 4 Fasten the compressor down securely if transporting is necessary Pressure must be released from the tank before transporting 5 Protect the air hose and electric cord from damage and puncture Inspect them weekly for weak or worn spots and replace if necessary 6 To reduce the risk of electric shock do not expose to rain Store indoors 7 Never operate the compressor if the power cord or plug are damaged Take the equipment to the nearest Authorized Service Center and a specialist technician will replace it CAUTION 4 200 2569 1 RISQUES D INCENDIE OU D EXPLOSION Ne jamais vaporiser de liquides inflammables dans un endroit confin Il est normal que le moteur et le manostat produisent des tincelles pendant le fonctionnement Si les tincelles entrent en contact avec les vapeurs d essence ou d autres solvants ces vapeurs peuvent s enflammer et causer un incendie ou une explosion Utilisez toujours le compresseur dans une zone bien a r e Ne fumez pas quand
32. ada Es normal que el motor y el interruptor de presi n produzcan chispas al estar en funcionamiento Si las chispas entran en contacto con los vapores de la gasolina o con otros disolventes stos podr an encenderse causando un incendio o una explosi n Siempre opere el compresor en un lugar bien ventilado No fume al rociar No roc e donde existan chispas o llama Mantenga el compresor tan lejos del lugar de rociado como sea posible 2 RIESGO DE EXPLOSI N La corrosi n puede debilitar el tanque Drene el agua condensada del tanque despu s de cada uso para reducir la oxidaci n Si detecta una fuga en el tanque reempl celo inmediatamente No suelde no perfore ni modifique el tanque del aire de este compresor La soldadura o las modificaciones en el tanque del compresor de aire podr an deteriorar gravemente la resistencia del tanque y causar una condici n extremadamente peligrosa Soldar o modificar el tanque de cualquier manera anular la garant a 3 RIESGO DE DESCARGA EL CTRICA Un electricista autorizado debe hacer todas las conexiones de acuerdo con todos los c digos el cricos nacionales y locales Nunca utilice un compresor el ctrico de aire en el exterior cuando est lloviendo ni lo coloque sobre una superficie mojada ya que esto podr a causar descargas el ctricas 4 RIESGO DE LESIONES Esta unidad arranca autom ticamente SIEMPRE apague el compresor quite el enchufe del tomacorrientes y purgue toda la
33. aire comprimido El interruptor de presi n vea D apaga el motor y alivia la presi n del aire en la bomba y el tubo de transferencia cuando la presi n del aire en el tanque alcanza el l mite establecido en f brica Al ir us ndose el aire comprimido y bajar el nivel de presi n en el tanque hasta llegar al nivel preestablecido el interruptor de presi n vuelve a arrancar el motor y la bomba contin a comprimiendo el aire El panel desmontable ver E le permite mover los controles del compresor sin tener que mover el compresor El mango retr ctil ver F puede jalarse para mover el compresor y empujarse hacia adentro para que no ocupe mucho espacio al guardarlo OVERVIEW VUE D ENSEMBLE RESUMEN GENERAL BASIC AIR COMPRESSOR COMPONENTS L MENTS DE BASE DU COMPRESSEUR D AIR COMPONENTES B SICOS DEL COMPRESOR DE AIRE 200 2569 7 PUMP SHIPPED WITHOUT OIL Fill pump to correct mark and check often SAE 10W 30 All weather air compressor oil is recommended for general use 1 Unpack the air compressor Inspect the unit for damage If the unit has been damaged in transit contact the carrier and complete a damage claim Do this immediately because there are time limitations to damage claims The carton should contain air compressor operator and parts manuals Wheels 2 amp Cotter pins 2 2 Check the compressor s serial label to ensure that you have received the model ordered and that it has the requ
34. and plug your air hoses into the quick connects H on front of the panel Manostat voir A Cet interrupteur met en marche le compresseur Il est actionn manuellement mais s il se trouve sur la position ON le compresseur se met en marche ou s arr te automatiquement sans avertissement en fonction de la demande d air R glez TOUJOURS cet interrupteur sur la position OFF quand vous n utilisez pas le compresseur et avant de le d brancher Soupape de d charge voir B Si le manostat n arr te pas le moteur quand la pression atteint le niveau pr d fini cette soupape s ouvre automatiquement pour viter toute surpressurisation Pour l actionner manuellement tirez sur son anneau af n de lib rer la pression d air dans le r servoir Manom tre du r servoir voir C Ce manom tre mesure le niveau de pression d air dans le r servoir L utilisateur ne peut pas r gler ce manom tre et il n indique pas la pression dans la conduite R gulateur de pression d air voir D Le r gulateur de pression d air permet de r gler la pression de la conduite de l outil que vous utilisez Ne d passez jamais la pression maximum nominale de l outil Tournez le bouton dans le sens des aiguilles d une montre pour augmenter la pression et dans le sens inverse pour la r duire Manom tre de pression r gul e voir E Ce manom tre mesure la pression de sortie r gul e Sortie d air du compresseur voir F Le panneau amovible avant I est raccord
35. be plugged into a dedicated circuit as close as possible to the fusebox or circuit breaker The compressor will use the full capacity of a typical 15 amp household circuit If any other electrical devices are drawing from the compressor s circuit the compressor may fail to start Low voltage or an overloaded circuit can result in sluggish starting that causes the motor overload protection system or circuit breaker to trip especially in cold conditions NOTE A circuit breaker is recommended If the air compressor is connected to a circuit protected by a fuse use dual element time delay fuses Buss Fusetron type T only NOTE Avoid use of extension cords For optimum performance plug the compressor power cord directly into a grounded wall socket Do not use an extension cord unless absolutely necessary Instead use a longer air hose to reach the area where the air is needed If use of an extension cord cannot be avoided the cord should be no longer than 50 feet and be a minimum wire size of 12 gauge AWG Do not use a 16 or 14 gauge extension cord Use only a 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the product Make sure your extension cord is in good condition An undersized cord will cause a drop in line voltage resulting in loss of power and overheating The smaller the gauge number the heavier the cord This product should be grounded In the event of an
36. co conectado a tierra consulte INSTRUCCIONES DE PUESTA A TIERRA vea 11 Evite el uso de un cord n prolongador es preferible usar una manguera m s larga b El compresor debe estar a una distancia m nima de 12 pulgadas 31 cm de cualquier pared u obstrucci n en un rea limpia y bien ventilada para asegurar que exista suficiente flujo de aire y enfriamiento c En climas fr os almacene el compresor port til en un edificio con calefacci n Esto reducir problemas de lubricaci n arranque del motor y congelamiento del agua de condensaci n d Separe el compresor de la plataforma de transportaci n y col quelo en el piso sobre una superficie dura y nivelada El compresor debe quedar nivelado para asegurar un drenaje adecuado del agua de humedad del tanque e Las ruedas est n desarmadas Retire 2 ruedas B y 2 pasadores A de la caja Coloque la rueda en el eje e introduzca el pasador en el orificio abra los extremos para asegurarlo ver Fig 1 4 Conecte hasta 2 mangueras de aire no incluidas a los conectores r pidos en el panel delantero desmontable ver p gina 8 para obtener m s detalles ASSEMBLY ASSEMBLAGE MONTAJE ASSEMBLING THE COMPRESSOR ASSEMBLAGE DU COMPRESSEUR MONTAJE DEL COMPRESOR Fig 1 8 200 2569 PRESSURE switch see A This switch turns on the compressor It is operated manually but when in the ON position it allows the compressor to start up or shut down automatically withou
37. disparado Verifique que el fusible sea adecuado El fusible Fusetron tipo T es aceptable Verifique que el voltaje no sea bajo y que el tama o del cable de extensi n sea adecuado Desconecte otros dispositivos del circuito Opere el compresor en un circuito dedicado Qu tela y l mpiela o reempl cela La v lvula de retenci n se bloque en posici n abierta Purgue la l nea moviendo la palanca del conmutador activado por presi n a la posici n APAGADO antes de volver a arrancar Si la v lvula de purga no se abre reempl cela La v lvula de purga de presi n en el conmutador activado por presi n no ha liberado la presi n de ca da Verifique que el calibre y la longitud del cable de extensi n sean adecuados Alambre de calibre inadecuado en el cable o longitud excesiva del cable de extensi n Comun quese con un centro de servicio autorizado Conexiones el ctricas sueltas Comun quese con un centro de servicio autorizado Posiblemente el capacitor est defectuoso Haga que lo revisen en un centro de servicio No opere el compresor en un rea donde pinten con pistola Pintura de pistola en las piezas internas del motor Haga que lo revisen en un centro de servicio Posiblemente el motor est defectuoso El motor se atasca Proporcione la potencia adecuada Bajo voltaje Reemplace la v lvula de purga con conmutador activado por presi n V lvula de purga con conmutador activado po
38. dor de presi n de aire permite ajustar la presi n en la l nea que conecta la herramienta que se est usando Nunca sobrepase el ndice m ximo de presi n de la herramienta Gire la perilla a la derecha para aumentar la presi n y a la izquierda para disminuirla Man metro regulado vea E Este man metro mide la presi n regulada de salida Salida del tubo de aire del compresor ver F El panel delantero desmontable I est conectado a la salida del tubo de aire del compresor F ubicado detr s del panel Para usar el panel sin mover el compresor gire la perilla G en sentido horario 1 4 de vuelta hacia la derecha luego levante el panel y s quelo Desconecte la manguera de aire corta que conecta el panel con la salida del tubo de aire Conecte un extremo de una manguera de aire no incluida a la salida del tubo de aire del compresor F y el otro extremo a la manguera del panel delantero desmontable ver Fig 2 Mueva el panel al rea de trabajo y conecte sus mangueras de aire a los conectores r pidos H en el frente del panel WARNING AVERTISSEMENT ADVERTENCIA COMPRESSOR CONTROLS COMMANDES DU COMPRESSEUR CONTROLES DEL COMPRESOR COMPRESSOR CONTROLS COMMANDES DU COMPRESSEUR CONTROLES DEL COMPRESOR 200 2569 9 Refer to the air compressor s serial label for the unit s voltage and amperage requirements Use a dedicated circuit For best performance and reliable starting the air compressor must
39. eite en cada bomba con la mirilla de vidrio El nivel de aceite en la bomba debe estar en la marca correspondiente a lleno en la mirilla de vifrio vea X y Y E No ponga demasiado ni muy poco aceite en la bomba 2 Coloque el conmutador activado por presi n en la posici n APAGADO vea A 3 Abra la llave de descompresi n vea B H galo girar hacia la izquierda 4 Enchufe el cord n el ctrico 5 Coloque el conmutador activado por presi n en la posici n ENCENDIDO vea C El compresor arrancar Permita el funcionamiento del compresor durante 30 minutos a fin de suavizar los componentes internos NOTA Si despu s de 30 minutos la unidad no opera correctamente AP GUELA INMEDIATAMENTE y p ngase en contacto con el Centro de Servicio 6 Despu s de aproximadamente 30 minutos coloque el conmutador activado por presi n en la posici n APAGADO 7 Cierre la llave de descompresi n vea D 8 Coloque el conmutador activado por presi n en la posici n ENCENDIDO H galo girar hacia la derecha El compresor comenzar a funcionar llenar el tanque hasta la presi n de desconexi n y dejar de funcionar NOTA Al utilizar el aire comprimido el interruptor de presi n arrancar autom ticamente el motor B OPEN OUVERT ABIERTO D CLOSE FERM SE CIERRAN E BREAK IN OF THE PUMP RODAGE DE LA POMPE MARCHA INICIAL DE LA BOMBA BREAK IN OF THE PUMP RODAGE DE LA POMPE MARCHA INICIAL DE LA BOMBA
40. ement verte avec ou sans rayures jaunes Ce produit est con u pour fonctionner sur un circuit d une tension nominale de 115 volts Un c ble muni d une prise de terre comme illustr ici doit tre utilis Veillez ce que le compresseur soit branch sur une prise de courant compatible avec la fiche Figure 1 N utilisez pas d adaptateur avec ce produit Si vous ne comprenez pas les instructions de mise la terre ou si vous doutez que le compresseur soit correctement mis la terre consultez un lectricien qualifi Ne modifiez pas la fiche fournie avec l appareil si elle ne s adapte pas la prise de courant faites installer une prise de courant correcte par un lectricien qualifi Consulte el r tulo del n mero de serie del compresor de aire para ver los requerimientos de voltaje y amperaje de la unidad Use un circuito exclusivo Para el mejor rendimiento y un arranque confiable el compresor de aire debe conectarse en un circuito exclusivo tan cerca como sea posible de la caja de fusibles o del cortacircuito El compresor utilizar la capacidad m xima de un circuito de 15 amperios de una casa normal Si hay otros equipos el ctricos que est n consumiendo energ a del circuito al cual est conectado el compresor es posible que ste no arranque Un voltaje bajo o un circuito sobrecargado puede causar un arranque lento que causar que salte el interruptor de reposicionamiento del motor o el cortacircuito especialm
41. ente en condiciones de baja temperatura NOTA Se recomienda un disyuntor Si el compresor de aire se conecta a un circuito protegido por un fusible utilice fusibles temporizados de doble elemento s lo Buss Fusetron tipo T NOTA Evite el uso de cordones prolongadores Para obtener un rendimiento ptimo enchufe el cord n el ctrico del compresor directamente en un tomacorriente de pared conectado a tierra No use un cord n prolongador a menos que sea absolutamente necesario Como alternativa intente utilizar una manguera de aire m s larga para llegar a la zona donde se requiere aire el cable no debe tener una longitud mayor que 9 1 m 50 pies y un alambre con calibre m nimo de 12 AWG No use cables de extensi n de calibre 14 ni 16 Use solamente un cord n de 3 alambres que tenga un enchufe de 3 patas y un recept culo de 3 ranuras que permita el enchufe del producto Aseg rese de que su cord n prolongador est en buenas condiciones Un cord n demasiado peque o causar una ca da en el voltaje de la l nea causando una p rdida en la energ a y un sobrecalentamiento Cuanto m s peque o sea el n mero de calibre tanto m s pesado ser el cord n Este producto debe conectarse a tierra En el caso de un cortocircuito el ctrico la conexi n a tierra reduce el riesgo de choque el ctrico pues ofrece un escape para la corriente el ctrica Este producto est equipado con un cord n que tiene un alambre de conexi
42. essure switch Pressure switch stuck Motor will start automatically when tank pressure drops below kick in pressure of pressure tank Tank pressure exceeds preset pressure switch limit Let motor cool off and overload switch will automatically reset This may take several minutes Motor overload protection has tripped Replace blown fuse or resed circuit breaker Do not use fuse or circuit breaker with higher rating than specified for your branch circuit Fuse blown or circuit breaker tripped Check for proper fuse Fusetron type T is acceptable Check for low voltage and proper extension cord size Disconnect other applications from circuit Operate compressor on a dedicated circuit Remove and clean or replace Check valve stuck open Bleed line by moving pressure switch lever to OFF Position before restarting If bleeder valve does not open replace bleeder valve Pressure bleeder valve on pressure switch has not unloaded head pressure Check for proper gauge and extension cord length Wrong wire gauge in cord or excessive extension cord length Contact authorized service center Loose electrical connections Contact authorized service center Possible defective capacitor Have checked at service center Do not operate compressor in the paint spray area Paint spray on internal motor parts Have checked at service center Possible defective motor SOLUTION POSSIBLE CAUSE Pressure rel
43. f the body Equipment can cause serious injury if the spray penetrates the skin 9 RISK OF BURSTING Do not adjust the pressure switch or relief valve for any reason Doing so voids all warranties They have been preset at the factory for the maximum pressure of this unit Personal injury and or property damage may result if the pressure switch or the relief valve are tampered with 10 RISK OF BURSTING Do not use plastic or pvc pipe for compressed air Use only galvanized steel pipe and fittings for compressed air distribution lines 11 RISK TO HEARING Always wear hearing protection when using an air compressor Failure to do so may result in hearing loss 12 RISK TO BREATHING Never directly inhale the compressed air produced by a compressor It is not suitable for breathing purposes 13 The power cord on this product contains lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling WARNING SAFETY GUIDELINES The following information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS To help you recognize this information we use the following symbols Please read the manual and pay attention to these sections A POTENTIAL HAZARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE A POTENTIAL HAZARD THAT COULD CAUSE SERIOUS INJURY OR LOSS OF LIFE A POTENTIAL HAZARD THAT MAY CAUSE MODERATE INJURY OR DAMAGE TO EQ
44. ief valve opens Motor will not run PROBLEM TROUBLESHOOTING CHART 20 200 2569 Remarque Les probl mes de d pannage peuvent avoir des causes et des solutions similaires Fermer le robinet R duire l utilisation d air comprim Robinet de r servoir ouvert SOLUTION CAUSE POSSIBLE V rifier les raccords l eau savonneuse Resserrer ou tanch ifier les raccords NE PAS TROP SERRER Fuite des raccords Nettoyer ou remplacer l l ment du filtre air Entr e d air obstru e Usage excessif d air Faible pression ou manque d air ou compresseur fonctionnant sans arr t PROBL ME D marrages et arr ts fr quents sans utilisation Fuite d air du r gulateur ou mauvaise r gulation de la pression La lecture du manom tre chute lors de l utilisation d air Le disjoncteur se d clenche le fusible grille trop souvent Surchauffe Le moteur cale V rifier le d bit d air requis pour les accessoires S il est sup rieur au d bit PCM et la pression fournis par le compresseur celui ci doit tre plus puissant La plupart des accessoires sont valu s 25 de leur d bit PCM r el en fonctionnement continu Compresseur pas assez puissant D monter nettoyer ou remplacer le clapet Clapet de retenue obstru V rifier ou remplacer au besoin Fuite d un tuyau pneumatique Remplacer imm diatement l unit NE PAS tenter une r paration Fuite du r servoir Remplacer les
45. ification Chart________Tableau des sp cifications_______Cuadro de especificaciones Questions See back page _____Questions Consultez la page final _____ Preguntas Vea la p gina final 1 06 MODEL NO MOD LE MODELO RUNNING H P CV TANK CAPACITY GALLONS CAPACIT DU R SERVOIR LITRES CAPACIDAD DEL TANQUE LITROS VOLTAGE AMPS PHASE TENSION AMPS PHASE VOLTAJE AMP FASE KICK IN PRESSURE PRESSION D OUVERTURE PRESION DE CONEXION KICK OUT PRESSURE PRESSION DE FERM PRESION DE DESCONEXION BS0880504 8 5 19 0 120 15 1 95 6 55 bar 125 8 62 bar 2 200 2569 SAFETY GUIDELINES 3 OVERVIEW 6 Basic Air Compressor Components 6 ASSEMBLY 7 Assembling the Compressor 7 COMPRESSOR CONTROLS 8 ELECTRICAL POWER REQUIREMENTS 9 Electrical Wiring 9 Extension Cords 9 Grounding Instructions 9 BREAK IN OF THE PUMP 11 OPERATING INSTRUCTIONS 1
46. ired pressure rating for its intended use 3 Locate the compressor according to the following guidelines a Position the compressor near a grounded electrical outlet see GROUNDING INSTRUCTIONS page 10 Avoid using an extension cord use a longer hose instead b The compressor must be at least 12 inches 31 cm from any wall or obstruction in a clean well ventilated area to ensure sufficient air flow and cooling c In cold climates store portable compressors in a heated building when not in use This will reduce problems with motor starting and freezing of water condensation d Remove the compressor from the shipping pallet or carton and place it on the floor or a hard level surface The compressor must be level to ensure proper drainage of the moisture in the tank e The wheels are disassembled Remove 2 wheels B and 2 cotter pins A from the carton Place the wheel on the axle and insert the cotter pin into the hole and spread the ends apart to secure see Fig 1 4 Connect up to 2 air hoses not included to the to the quick connects on the removable front panel see page 8 for more details LA POMPE QUI EST EXP DI E NE CONTIENT PAS D HUILE Remplissez la pompe jusqu au niveau correct et v rifiez souvent le niveau De l huile tous temps de compresseur de l air 10W 30 est recommand e pour l usage g n ral 1 Sortez le compresseur d airde sa bo te Inspectez le pour vous assurer qu il n est
47. is normal Check air requirement of accessory If it is higher than CFM and pressure supplied by compressor you need a larger compressor Most accessories are rated at 25 of actual CFM while running continuously Compressor not large enough Furnish adequate power If using extension cord try without Low voltage Consult electrician Excessive wire length Contact authorized service center Restricted air passages Replace check valve pressure switch bleeder valve Back pressure in pump head SOLUTION POSSIBLE CAUSE Low pressure or not enough air or Compressor does not stop Excessive starting and stopping while not in use Air leaks from regulator or regulator does not regulate pressure Regulated pressure gauge reading drops when air accessory is being used Circuit breaker trips fuse blows too often Relocate compressor to an area with cool dry and well circulated air Poor ventilation Clean all cooling surfaces of pump and motor thoroughly Dirty cooling surfaces Replace worn parts and reassemble with new seals Leaking valve Overheating Furnish adequate power Low voltage Replace pressure switch bleeder valve Defective pressure switch bleeder valve Motor stalls PROBLEM WARNING TROUBLESHOOTING CHART 200 2569 19 Note Troubleshooting problems may have similar causes and solutions Replace pressure switch Tank pressure exceeded normal operating pressure Replace pr
48. limas fr os drene el tanque despu s de cada uso a fin de reducir los problemas por el congelamiento del agua de condensaci n Un filtro de aire sucio reducir el rendimiento y la vida del compresor Para evitar la contaminaci n interna de la bomba el filtro se debe limpiar con frecuencia y reemplazar regularmente Los filtros de espuma se deben limpiar en agua jabonosa tibia No permita que el filtro se ensucie con tierra ni con pintura La exposici n directa a condiciones de suciedad o reas que se est n pintando anular la garant a Verifique el nivel de aceite en cada bomba con la mirilla de vidrio El nivel de aceite en la bomba debe estar en la marca correspondiente a lleno en la mirilla de vifrio vea X y Y No ponga demasiado ni muy poco aceite en la bomba NOTA Se recomienda el uso de aceite 10W 30 para compresor de aire para cualquier estaci n del a o Quite el tap n vea A de aceite y deje salir el aceite hasta que empiece a gotear luego vuelva a poner el tap n A ada aceite para compresor hasta que se encuentre entre las marcas Lleno vea X y Agregar vea Y Nunca se debe poner demasiado ni muy poco aceite en la bomba Tire de la v lvula de alivio todos los d as para asegurarse de que est operando correctamente y para eliminar cualquier obstrucci n posible de la misma Compruebe que todas las conexiones est n ajustadas Una peque a fuga en cualquiera de las mangueras tubos de transferencia
49. lle ne s ouvre pas La soupape d vacuation du manocontacteur n a pas rel ch la pression de la culasse V rifier le calibre et la longueur de la rallonge Calibre incorrect du fil ou rallonge trop longue Contacter un centre d entretien agr Mauvaises connexions Contacter un centre d entretien agr Condensateur d fectueux Contacter un centre d entretien agr Ne pas faire fonctionner le compresseur dans l aire de peinture Peinture vaporis e sur les pi ces internes du moteur Contacter un centre d entretien agr Possibilit de moteur d fectueux D PANNAGE 22 200 2569 Nota Los problemas de detecci n de fallos pueden tener causas y soluciones similares Cierre el grifo de desag e Disminuya la cantidad de aire usada El grifo de desag e del tanque est abierto SOLUCION CAUSA POSIBLE Revise las conexiones con agua jabonosa Apriete o vuelva a sellar las conexiones que tengan fugas NO LAS APRIETE EN EXCESO Las conexiones tienen fugas Limpie o reemplace el elemento del filtro de aire Toma restringida de aire Uso excesivo y prolongado de aire Presi n baja o insuficiente cantidad de aire o bien el compresor no se detiene PROBLEMA Arranque y detenci n excesivos mientras no se est usando Fugas de aire del regulador o el regulador no regula la presi n La lectura del man metro regulado disminuye cuando se est usando el accesorio de aire El dis
50. nctionne correctement et liminer toutes les obstructions ventuelles Assurez vous que tous les raccords sont serr s Le rendement de votre compresseur peut tre r duit de mani re significative en pr sence d une petite fuite d air dans les tuyaux flexibles les tubes de transfert ou les raccords de tuyauterie Si vous suspectez une fuite vaporisez un peu d eau savonneuse autour de la zone Si des bulles apparaissent r parez ou remplacez le composant d fectueux Ne serrez pas trop Avant d entreposer le compresseur pour une p riode prolong e utilisez une soufflette pour nettoyer toute la poussi re et tous les d bris du compresseur D branchez le cordon d alimentation et enroulez le Tirez sur la soupape de d charge pour lib rer toute la pression dans le r servoir vacuez toute l humidit du r servoir Nettoyez les l ments et le bo tier du filtre remplacez les l ments au besoin Couvrez tout l appareil pour le prot ger de l humidit et de la poussi re AVERTISSEMENT AVERTISSEMENT ENTRETIEN VIDANGE DU R SERVOIR NETTOYAGE DU FILTRE AIR V RIFICATION DU NIVEAU D HUILE VIDANGE D HUILE V RIFICATION DE LA SOUPAPE DE D CHARGE ESSAI D TANCH IT ENTREPOSAGE INTERVALOS DE SERVICO Effectuez l entretien suivant aux intervalles indiqu s ci dessous Inspectez et nettoyez le filtre air Chaque jour V rifiez le niveau d huile de la pompe Chaque jour Changez l huile
51. ne prise de courant 3 fentes dans laquelle la prise peut tre branch e Veillez ce que la rallonge que vous allez utiliser soit en bon tat Une rallonge de dimension inf rieure celle pr conis e causera une baisse de tension sur la ligne qui se soldera par une perte de puissance et une surchauffe Plus le calibre est petit plus la rallonge doit tre grosse Grounded Outlet Box Grounded Outlet Plug Grounding Pin DANGER Figure 1 115 VOLTS 15 AMP ELECTRICAL POWER REQUIREMENTS SP CIFICATIONS DE L ALIMENTATION LECTRIQUE REQUERIMIENTOS DE ALIMENTACI N EL CTRICA ELECTRICAL WIRING EXTENSION CORDS GROUNDING INSTRUCTIONS C BLAGE LECTIQUE RALLONGES 10 200 2569 Ce produit doit tre mis la terre En cas de court circuit lectrique la mise la terre r duit les risques de d charges lectriques en fournissant un fil par lequel le courant lectrique peut s chapper Ce produit est quip d un c ble d alimentation muni d un fil de terre et d une fiche de terre appropri e Cette fiche doit tre branch e sur une prise de courant qui t mise la terre et install e conform ment toutes les normes et d crets locaux L installation incorrecte de la fiche de terre risque de provoquer des d charges lectriques En cas de remplacement n cessaire du c ble ou de la fiche ne branchez pas le fil de terre sur l une des lames plate Le fil de terre est recouvert d une gaine d isol
52. ntre d Entretien ou le service apr s vente veuillez indiquer le num ro de mod le et le n mero de s rie situ sur la etiquette de s rie du compresseur Une preuve d achat est n cessaire lors de toute transaction et une copie de votre re u peut tre exig e Inscrivez la date d achat au dessus de dans les espaces r serv cet effet Conservez votre re u et ce manuel pour r f rence ult rieure Quand vous avez besoin des services de l usine s il vous pla t contactez au centre d entretien autoris le plus proche ou composez simplement le Product Service Au Canada Appel gratuit 1 800 445 1805 T l copieur 1 308 234 4187 Las piezas de repuesto y el servicio est n disponibles del Centro de Servicio autorizado m s cercano Consulte con el Servicio al Cliente Product Service listado debajo si surge la necesidad Refi rase al n mero de modelo y el n mero de serie situado en la etiqueta de serie del compresor cuando consulte con un Centro de Servicio o el Servicio al Cliente Se requiere la prueba de compra para todas las transacciones y puede requerirse una copia de su recibo de venta En los espacios provisto arriba registre la fecha de compra Guarde su recibo de venta y este manual para referencia futura Cuando necesite servicio por favor de consultar el centro de servicio autorizado m s cercano o notificar por correo a Product Service Powermate Corporation 4970 Airport Road Kearney
53. pas endommag S i a t endommag pendant le transport r f rez vous l tiquette de transport et d clarez les dommages aux transporteur Faites cette d marche imm diatement tant donn les d lais limites des demandes d indemnisation Le carton doit contenir compresseur d air manuel de l op rateur et manuel de pi ces Roues 2 et goupilles fendues 2 2 V rifiez l tiquette du num ro de s rie du compresseur pour vous assurer qu il s agit bien du mod le command et que la pression nominale est conforme l utilisation pr vue 3 Positionnez le compresseur conform ment aux recommandations suivantes a Placez le compresseur pr s d une prise de courant mise la terre voir INSTRUCTIONS DE MISE LA TERRE p 11 vitez d utiliser une rallonge utilisez plut t un tuyau flexible plus long b Le compresseur doit tre situ au moins 12 pouces 31 cm du mur ou de tout objet faisant obstruction dans un endroit propre et bien a r pour assurer une circulation d air suffisante et un bon refroidissement c Dans des climats froids entreposez les compresseurs portatifs dans un b timent chauff lorsqu ils ne sont pas en service pour r duire les probl mes de lubrification de d marrage du moteur et de gel de l eau produite par condensation d Enlever le compresseur de la pallette d exp dition ou du carton et le placer sur une surface solide et de niveau Le compresseu
54. pi ces us es et installer Fuite de soupape V rifier les raccords l eau savonneuse Resserrer ou tanch ifier les raccords NE PAS TROP SERRER Fuite des raccords Remplacer les pi ces us es et installer de nouveaux joints Remplacer le r gulateur Pi ces du r gulateur sales ou endommag es Si la pression chute trop ajuster le r gulateur pendant l utilisation de l accessoire Situation normale V rifier le d bit d air requis pour les accessoires S il est sup rieur au d bit PCM et la pression fournis par le compresseur celui ci doit tre plus puissant La plupart des accessoires sont valu s 25 de leur d bit PCM r el en fonctionnement continu Compresseur pas assez puissant Fournir la tension ad quate Si une rallonge est utilis e essayer sans Tension insuffisante Consulter un lectricien C bles lectriques trop longs Contacter un centre d entretien agr Voies d air obstru es Remplacer le clapet de retenue et la soupape d vacuation du manocontacteur Contre pression dans la culasse de la pompe Replacer le compresseur dans un endroit frais sec et offrant une bonne circulation d air Manque d a ration Nettoyer les surfaces de refroidissement de la pompe et du moteur Surfaces de refroidissement sales Fournir la tension ad quate Tension insuffisante Remplacer la soupape d vacuation du manocontacteur Soupape d vacuation du manocontacteur d fectue
55. r doit tre de niveau pour assurer un bon drainage de l humidit du r servoir e Les roues ne sont pas assembl es Retirez les 2 roues B et les 2 goupilles fendues A de la bo te Placez la roue sur l essieu ins rez une goupille fendue dans le trou et s parez les pattes pour bien les attacher voir fig 1 4 Raccordez 2 boyaux air non inclus aux raccords rapides situ s sur le panneau amovible avant voir les d tails la page 8 LA BOMBA SE ENVIA SIN ACEITE Poner aceite en la bomba hasta la marca correcta y verificar el nivel con freduencia El aceite para cualquier estaci n del compresor de aire 10W 30 se recomienta para el uso general 1 Desembale el compresor de aire Inspeccione la unidad para verificar que no sufri da os Si la unidad ha sido da ada durante el transporte comun quese con la empresa transportadora y complete una reclamaci n por da os Haga esto de inmediato porque existen limitaciones de tiempo respecto a las reclamaciones por da os La caja debe contener los elementos siguientes compresor de aire manual del operador y manual de piezas Ruedas 2 y pasadores 2 2 Verifique el r tulo del n mero de serie del compresor para asegurarse de que haya recibido el modelo que pidi y que el mismo tenga la presi n nominal requerida para el uso deseado 3 Ubique el compresor de acuerdo con las pautas siguientes a Ubique el compresor cerca de un tomacorriente el ctri
56. r presi n defectuosa Sobrecalentamiento Reubique el compresor en un rea donde haya aire fresco seco y con buena circulaci n Ventilaci n deficiente Limpie minuciosamente todas las superficies de enfriamiento de la bomba y del motor Superficies de enfriamiento sucias Reemplace las piezas desgastadas y vuelva a montar usando sellos nuevos Fugas en la v lvula CUADRO DE DETECCI N DE FALLOS Replacement parts and service are available from your nearest authorized Service Center If the need arises contact Product Service as listed at right When consulting with a Service Center or Product Service refer to the model number and serial number located on the serial label of the compressor Proof of purchase is required for all transactions and a copy of your sales receipt may be requested Record the model number serial number and date purchased in the spaces provided below Retain your sales receipt and this manual for future reference When needing service please contact the nearest authorized Service Center or call PRODUCT SERVICE In U S A or Canada Toll Free 1 800 445 1805 Fax 1 308 234 4187 Model No Serial No Date Purchased la date d achat la fecha de compra Pour pi ces de rechange et r parations de votre Centre d Entretien autoris le plus proche Au besoin veuillez contacter le service apr s vente Product Service au num ro de t l phone ou droite Lorsque vous appelez un Ce
57. raci n CAMBIO DE ACEITE A Oil drain plug Bouchon Tap n B Oil level sight glass Verre de vue de niveau d huile Cristal de la vista del nivel de aceite C Oil fill plug Bouchon de l orifice de remplissage d huile Tapon de llenado de aceite X Full Plein Lleno Y Add Ajoutez Agregar 200 2569 17 PARTS DRAWING DESSIN DES PI CES ESQUEMA DE LA PIEZAS PARTS LIST LISTE DE PI CES LISTA DE LAS PIEZAS Item Part No Qty Art No P Qt Art N m P Cant Description Description Descripci n 1 142 0146 1 Shroud Enveloppe Guardera 2 166 0138 1 Capacitor Condensateur Condensador 3 019 0218 1 Intake filter Filtre Filtro 4 040 0390 1 Pump motor assembly Ensemble pompe moteur Conjunto de bomba motor 5 064 0076 1 Elbow 90 Coude Codo 6 056 0066 1 Oil fill plug Bouchon Tap n 7 145 0466 1 Tube transfer Tube Tubo 8 145 0463 1 Tube bleeder
58. roporcione la potencia adecuada Si est usando un cable el ctrico intente operar sin l Bajo voltaje Consulte a un electricista Longitud excesiva del cable Comun quese con un centro de servicio autorizado Conductos de aire restringidos Reemplace la v lvula de retenci n la v lvula de purga con conmutador activado por presi n Contrapresi n en el cabezal de la bomba ADVERTENCIA CUADRO DE DETECCI N DE FALLOS 200 2569 23 Nota Los problemas de detecci n de fallos pueden tener causas y soluciones similares Reemplace el conmutador activado por presi n Deje que el motor se enfr e y el conmutador de sobrecargas se restablecer autom ticamente Esto puede tardar varios minutos La presi n del tanque excedi la presi n normal de operaci n SOLUCION CAUSA POSIBLE El conmutador activado por presi n se ator El motor arrancar autom ticamente cuando la presi n del tanque disminuya hasta un valor menor de la presi n de activaci n del conmutador activado por presi n La presi n del tanque excede el l mite preestablecido del conmutador activado por presi n El protector de sobrecargas del motor se dispar La v lvula de alivio de presi n se abre El motor no funciona PROBLEMA Reemplace el fusible fundido o reajuste el disyuntor No use fusibles ni disyuntores de clasificaci n mayor que la especificada para su circuito de derivaci n Fusible fundido o disyuntor
59. se de que la v lvula est funcionando adecuadamente y para eliminar cualquier obstrucci n en la v lvula 3 A fin de lograr una ventilaci n adecuada para el enfriamiento el compresor debe mantenerse a un m nimo de 31 cm 12 pulgadas de la pared m s cercana en una zona bien ventilada 4 Sujete el compresor muy bien si es necesario su transporte Debe liberarse la presi n del tanque antes de su transporte 5 Proteja la manguera de aire y el conducto el ctrico contra da os y pinchaduras Inspecci nelos todas las semanas para comprobar que no existen zonas d biles o desgastadas y reempl celos si fuera necesario 6 Para reducir el riesgo de choque el ctrico proteja la unidad de la lluvia Almacene en el interior 7 Nunca opere el compresor si el cord n de alimentaci n y o la clavija se encuentran da ados lleve el equipo al centro de servicio autorizado Coleman Powermate m s cercano a su domicilio para que un t cnio especializado lo reemplace PRECAUCI N PAUTAS DE SEGURIDAD La informaci n que sigue se refiere a la protecci n de SU SEGURIDAD y la PREVENCI N DE PROBLEMAS DEL EQUIPO Como ayuda para reconocer esta informaci n usamos los siguientes s mbolos Lea por favor el manual y preste atenci n a estas secciones UN POSIBLE RIESGO QUE CAUSAR LESIONES GRAVES O LA P RDIDA DE LA VIDA UN RIESGO POTENCIAL QUE PODR A PROVOCAR GRAVES LESIONES O MUERTE UN RIESGO POTENCIAL QUE PODRIA PROVOCA
60. t le compresseur doit tre plac une distance minimum de 31 cm 12 pouces du mur le plus proche dans une zone bien a r e 4 Si vous transportez le compresseur fixez le bien Avant de le transporter il faut d abord d pressuriser le r servoir 5 Prot gez le tuyau d air contre les risques d endommagement et de perforation Inspectez le chaque semaine pour d celer toute trace de faiblesse ou d usure et remplacez le au besoin 6 Pour r duire les risques de d charge lectrique prot gez l appareil de la pluie Entreposez le l int rieur 7 N utilisez jamais le compresseur si la prise ou le cordon lectrique est endommag Apportez l appareil dans un Centre de service autoris pour le faire remplacer par un technicien comp tent AVERTISSEMENT ATTENTION Les informations suivantes concernent VOTRE S CURIT et LA PROTECTION DU MAT RIEL CONTRE LES PANNES Pour vous aider identifier la nature de ces informations nous utilisons les symboles suivants Veuillez lire le manuel et pr ter attention ces sections DANGER POTENTIEL POUVANT ENTRA NER DE GRAVES BLESSURES OU LA MORT DANGER POUVANT CAUSER DES BLESSURES GRAVES VOIRE MORTELLES DANGER POUVANT CAUSER DES BLESSURES MOYENNEMENT GRAVES OU L ENDOMMAGEMENT DE L APPAREIL AVERTISSEMENT DANGER ATTENTION CONSIGNES DE S CURIT 200 2569 5 1 RIESGO DE INCENDIO O EXPLOSI N Nunca roc e l quidos inflamables en un rea confin
61. t warning upon air demand ALWAYS set this switch to OFF when the compressor is not being used and before unplugging the compressor Pressure Relief Valve see B If the pressure switch does not shut down the motor when pressure reaches the preset level this valve will pop open automatically to prevent over pressurization To operate manually pull the ring on the valve to relieve air pressure in the tank Tank Pressure Gauge see C This gauge measures the pressure level of the air stored in the tank It is not adjustable by the operator and does not indicate line pressure Air Pressure Regulator see D This air pressure regulator enables you to adjust line pressure to the tool you are using Never exceed the maximum working pressure of the tool Turn the knob clockwise to increase pressure and counterclockwise to decrease pressure Regulated pressure gauge see E This gauge measures the regulated outlet pressure Compressor air line outlet see F The removable front panel I is connected to the compressor air line outlet F located behind the panel To use the panel without moving the compressor turn the knob G clockwise 1 4 turn to the right then lift the panel up and out Unplug the short air hose that connects the panel to the air line outlet Connect one end of an air hose not included to the compressor air line outlet F and the other end to the removable front panel hose see Fig 2 Move the panel to the work area
62. tar quemaduras y otras lesiones NO toque el compresor durante su funcionamiento Permita que se enfr e antes de manipular o realizar el servicio Mantenga a los ni os alejados del compresor en todo momento 5 Coloque el conmutador activado por presi n en la posici n ENCENDIDO vea C Al efectuar un ajuste desde una presi n m s alta a una m s baja gire la perilla a la izquierda hasta que sobrepase el ajuste deseado despu s gire a la derecha hasta alcanzar la presi n deseada No exceda la presi n de operaci n de la herramienta o del accesorio que est usando 6 Si su compresor tiene un regulador de presi n aj stelo en la presi n de trabajo de la herramienta 1 Coloque el conmutador activado por presi n en la posici n APAGADO vea A 2 Desenchufe el cord n el ctrico 3 Reduzca la presi n en el tanque a trav s de la manguera de salida Tambi n puede tirar del anillo de la v lvula de alivio vea F y mantenerla abierta para aliviar la presi n en el tanque El aire y la humedad que escapan del tanque pueden arrojar desechos que podr an causarle da o en los ojos Al abrir la llave de descompresi n use gafas de seguridad 4 Incline el compresor si es necesario en caso de su modelo para que el grifo de desag e quede en el fondo del tanque o tanques Luego abra el grifo de desag e vea B para permitir que el agua de la humedad drene del tanque ATTENTION AVERTENCIA AVERTENCIA PRECAUCI N
63. use Remplacer les pi ces us es et installer de nouveaux joints Fuite de soupape AVERTISSEMENT D PANNAGE 200 2569 21 Remarque Les probl mes de d pannage peuvent avoir des causes et des solutions similaires Remplacer le manocontacteur Laisser le moteur refroidir et le limiteur de surcharge se r armera automatiquement apr s quelques minutes La pression du r servoir d passe la limite normale SOLUTION CAUSE POSSIBLE Manocontacteur bloqu Le moteur d marre automatiquement lorsque la pression du r servoir chute sous la pression d enclenchement du manocontacteur La pression du r servoir d passe la limite pr r gl e du manocontacteur Le limiteur de surcharge s est d clench La soupape de s ret s ouvre PROBL ME Le moteur ne d marre pas Remplacer le fusible ou r armer le disjoncteur Ne pas utiliser de fusible ou de disjoncteur d une valeur sup rieure la puissance du circuit Fusible grill ou disjoncteur d clench V rifier le fusible le type T Fusetron est acceptable V rifier la faible tension et le calibre de la rallonge D brancher les autres appareils du circuit Faire fonctionner le compresseur sur un circuit r serv D monter nettoyer ou remplacer Le clapet de retenue est bloqu ouvert Purger le conduit en pla ant le levier du manocontacteur en position ARR T avant de red marrer Remplacer la soupape d vacuation si e
64. vous pulv risez Ne pulv risez pas en pr sence d tincelles ou d flammes Placez le compresseur aussi loin que possible de la zone de pulv risation 2 RISQUE D CLATEMENT La rouille peut affaiblir le r servoir Purger l eau de condensation du r servoir apr s chaque usage afin de r duire la corrosion Si une fuite est d cel e remplacer le r servoir imm diatement Ne soudez pas ne percez pas ou ne modifiez pas le r servoir d air de ce compresseur La soudure ou des modifications sur le r servoir du compresseur d air peut sensiblement alt rer sa solidit et causer des conditions d utilisation extr mement dangereuses La soudure ou la modification quelconque du r servoir entra nera l annulation de la garantie 3 RISQUE DE CHOC LECTRIQUE Un lectricien agr doit installer le c blage conform ment aux codes d lectricit nationaux et locaux N utilisez jamais un compresseur d air lectrique l ext rieur quand il pleut ou sur une surface mouill e sous peine de vous exposer une d charge lectrique 4 RISQUE DE BLESSURE Cet appareil se met en marche automatiquement Arr ttez TOUJOURS le compresseur d branchez le de la prise de courant et purgez toute la pression du circuit avant de proc der l entretien du compresseur ou lorsque vous ne l utilisez pas N utilisez pas l appareil sans les protections ou le garde courroie Risque de blessures graves en cas de contact avec les pi
65. yuntor se dispara los fusibles se queman con mucha frecuencia Verifique el requerimiento de aire del accesorio Si es mayor que el volumen por minuto CFM y la presi n suministrados por el compresor necesita un compresor m s grande La mayor a de los accesorios est n clasificados a un 25 del volumen real por minuto en funcionamiento continuo El compresor no es suficientemente grande Qu tela y l mpiela o reempl cela V lvula de retenci n restringida Rev sela y reempl cela si es necesario Hay un orificio en la manguera de aire Reemplace inmediatamente la unidad NO intente repararlo Fugas en el tanque Reemplace las piezas desgastadas y vuelva a montar Fugas en la v lvula Revise las conexiones con agua jabonosa Apriete o vuelva a sellar las conexiones que tengan fugas NO LAS APRIETE EN EXCESO Las conexiones tienen fugas Reemplace las piezas desgastadas y vuelva a montar usando sellos nuevos Reemplace el regulador Piezas internas del regulador sucias o da adas Si la presi n disminuye demasiado ajuste el regulador mientras use el accesorio Es normal Verifique el requerimiento de aire del accesorio Si es mayor que el volumen por minuto CFM y la presi n suministrados por el compresor necesita un compresor m s grande La mayor a de los accesorios est n clasificados a un 25 del volumen real por minuto en funcionamiento continuo El compresor no es suficientemente grande P
66. z le robinet de purge en bas du r servoir pour vidanger REMARQUE Dans les climats froids purger le r servoir apr s chaque utilisation afin de r duire les probl mes de gel d eau de condensation Un filtre air sale nuit aux performances et la durabilit du compresseur Pour viter de contaminer l int rieur de la pompe nettoyer le filtre fr quemment et le remplacer r guli rement Nettoyer les filtres en mousse l eau ti de savonneuse Ne pas laisser de salet s ou de peinture obstruer le filtre L exposition directe des conditions poussi reuses ou une aire de peinture annulera votre garantie V rifiez le niveau d huile dans chaque pompe avec le viseur voir X et Y Le niveau d huile de la pompe doit tre au rep re maximum sur le viseur Ne remplissez pas trop et remplissez suffisamment REMARQUE De l huile toutes saisons pour compresseur d air 10W 30 est recommand e pour un usage g n ral D posez le bouchon voir A de l orifice de vidange d huile et vidangez l huile jusqu ce que l coulement ralentisse et que l huile ne fasse que s goutter Remettez ensuite le bouchon Ajoutez de l huile pour compresseurs jusqu ce que le niveau d huile soit entre le rep re sup rieur MAX voir X et le rep re inf rieur MIN voir Y Ne remplissez jamais trop la pompe mais remplissez la suffisamment Tirez chaque jour sur la soupape de d charge pour vous assurer qu elle fo