Home
Instructions
Contents
1. 6 flange of Canopy should be facing away from Channel insert fixture leads through slot on appropriate Canopy and secure with Screw 8 32x1 1 4 5 provided Repeat for second Canopy See Fig 4 WIRING AND FIXTURE OPERATION CAUTION Connect fixture to supply wires rated for at least 90 C 194F Do not use fixture on dimming circuits 5 To wire Channel With the power turned off connect the black supply wire to the black wire from the Channel then connect white power supply wire to white striped fixture wire Ground fixture by connecting the green fixture wire to the bare copper supply wire If house wiring does not include a ground wire consult your local electrical code for approved grounding methods Tuck wires into junction box FOR PROPER CONNECTION PLACE WIRENUT OVER WIRES TWIST CLOCKWISE UNTIL TIGHT 6 Position Canopy 3 over Mounting Plate 1 by align ing Screw threads to protrude through holes in Canopy Secure with Finials 10 7 Install Lamps 11 by inserting Lamp pins into slot at top of sockets and rotating Lamps until they click 8 Turn on electricity at fuse or circuit breaker box to verify success of installation 9 Diffuser Assembly With open end of Diffuser 13 facing Lamp position Diffuser over Lamps and slide inside End Cap flange Secure Diffuser by securing second End Cap on opposite end of Channel To clean wipe fixture with a soft cloth Clean diffuser with a mild soap and
2. ou soumis une temp rature ambiante lev e L appareil doit tre connect une tension d alimentation nominale de 120 V 60 Hz Toujours employer une lampe du m me type et de la m me puissance que celle incluse ou sp cifi e pour l appareil d faut de quoi la garantie sera annul e Cet appareil est pr vu pour un raccordement une bo te de jonction homologu e UL non fournie install e correctement avec mise la terre et doit tre install conform ment aux codes du b timent locaux et NEC AVERTISSEMENT DANGER DE CHOC ELECTRIQUE Afin d viter les blessures caus es par une d charge lectrique il faut prendre les pr cautions suivantes avant d installer un lu minaire Couper le courant au bo tier disjoncteurs ou fusibles avant l installation Toujours couper le courant pour le changement des lampes ou l entretien Effectuer la mise la terre du luminaire pour viter tout choc lectrique ventuel et assurer l allumage Toujours v rifier les connexions afin qu elles soient ad quates et solides Cet appareil est destin un circuit d ali mentation prot g par un fusible ou un dis joncteur Il doit tre install selon le code de l lectricit applicable En cas de dou tes faire appel un lectricien ou un ins pecteur en lectricit et v rifier le code de l lectricit en vigueur AVERTISSEMENT DANGER DE COUPURES Certaines pi ces de m tal pourraien
3. DES PIECES Description Quantit 1 Plaque de montage o ooocccoicccccccncnoo 1 2 Vis 32X1 1 8 conocccccccccnccnnnnno Pavillon de recouvrement Vis 8 32 x 1 1 2 ccccccccccnaccncconnnnnnnn Vis 8 32 x 1 1 4 cccccccccccccncconnnnncnn crous bille Capuchon de connexion Fa teau EA 12 Embolt ccocitacinta tii 13 Diffuseur oooooccconococonocconcccconaconancninnncnn 1 Compris dans les sacs d emballage 3 4 5 6 7 Couvercle de t le en U 8 9 10 Lampes et Quincaillerie de Montage Incluses Page 2 STEP BY STEP GUIDE 1 Remove fixture components and parts pack s Check that all parts are included See Figure 1 Unscrew one end cap and slide diffuser off and remove both lamps Remove packing material Warning Safely dispose of packaging materials NOTE Turn off power on circuit breaker box 2 Prepare Mounting Plate 1 for mounting by installing Screws 8 32x1 1 8 2 into Mounting Plate as shown in Fig 2 3 With the power turned off at circuit breaker box position Mounting Plate 1 near the junction box and feed supply wires through center hole position with installed Screws aligned vertically after mounting and threads facing outward Secure using Screws 8 32x1 1 2 4 provided See Fig 3 4 To install Canopy align hole and slot on Canopy 3 with hole and slot on back of Channel
4. seguridad siempre recuerde lo siguiente Desconecte la corriente el ctrica en la caja de fusibles o de cortacircuito antes de instalar la luminaria Desconecte la corriente el ctrica cada vez que cambie las l mparas o para darle mantenimiento en el futuro Conecte a tierra la luminaria para evitar posible descarga el ctrica y asegurar que funcione aecuadamente Revise dos veces todas las conexiones para asegurarse que est n bien apretadas y correctamente instaladas Esta luminaria est dise ada para ser usada en un circuito protegido por un fusi ble o cortacircuitos e instalada de acuerdo con los c digos de electricidad locales Si no est seguro de su alambrado consulte con un electricista calificado o al inspector de electricidad local y verifique su c digo de electricidad local A R DVERTENCIA IESGO DE LESI N Algnas partes de metal de esta luminaria pueden tener bordes muy afilados Para prevenir cortaduras y raspaduras use guantes al instalar las piezas Recoja todas las piezas peque as sobrantes y destruyalas junto con el material de embalaje ya que stos pueden ser peligrosos a los ni os PRECAUCI N RIESGO DE FUEGO Conductores de suministrode m nimo de 90 C Page 3 IMPORTANTES MESURES DE SECURITE L appareil ne peut tre utilis sur un gradateur d intensit Cet appareil est con u pour un usage l int rieur SEULEMENT et ne doit pas tre utilis dans un lieu mal a r
5. 11 ins rer les broches dans la rainure de chaque douille et tourner les lampes jusqu ce que vous entendrez un d clic 8 R tablir l lectricit au fusible ou au disjoncteur et v rifier le succ s de l installation 9 Assemblage du diffuseur Le c t ouvert du diffuseur 13 face aux lampes position le diffuseur sur les lampes glisser l int rieur du rebord de l embout Solidifier le diffuseur en posant l autre extr mit avec le second embout du c t oppos de la t le en U Guide de d pannage En cas d un fonctionnement inad quat de cet appareil suivre le guide ci dessous pour tablir le diagnostic et corriger le probl me m Confirmer l emploi des bonnes lampes S assurer que la lampe est bien ins rer dans la douille Remplacer toute lampe d fectueuse V rifier que l appareil est raccord correctement V rifier que la mise la terre de l appareil est correcte V rifier que la tension l appareil est suffisante Pour toute autre assistance veuillez contacter nos services de support technique Consumer Products Technical Support 800 748 5070 L installation d un ballast de rechange doit tre effectu e par un lectricien comp tent Pour le nettoyage essuyer l appareil l aide d un linge doux Nettoyer le diffuseur l aide d un savon doux et de l eau Ne pas employer de produits abrasifs comme les tampons ou poudres r curer la laine d acier ou un papier abrasif Ne
6. IMPORTANT SAFETY INSTRUCTIONS Fixture cannot be used with a dimmer switch This fixture is designed for indoor use ONLY and should not be used in areas with limited ventilation or high ambient temperatures Fixture must be connected to a nominal 120Volt 60 Hz power source Any other connection voids warranty Always use the same wattage and type of lamp included or specified for the fixture Failure to do so will void warranty This fixture is intended to be connected to a properly installed and grounded UL listed junction box not provided and should be installed according to NEC and local building codes WARNING RISK OF SHOCK Electric current can cause painful shock or serious injury unless handled properly For your safety always Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply Turn off the power when you change lamps or perform other maintenance Ground the fixture to avoid potential electric shocks and to ensure reliable starting Double check all connections to be sure they are tight and correct This fixture is designed for use in a circuit protected by a fuse or circuit breaker and to be installed in accordance with national and local electrical codes If you are unsure about your wiring consult a qualified electrician or local electrical inspector and check your local electrical code WARNING RISK OF INJURY Some metal parts in the fixture may have sh
7. arp edges To prevent cuts and scrapes wear gloves when handling the parts Account for small parts and destroy packing material as these may be hazardous to children CAUTION RISK OF FIRE Minimum 90 C supply conductors LA LAMPE CONTIENT DU MERCURE LAMPARA CONTIENE MERCURIO fg LAMP CONTAINS MERCURY Manage in Accordance with Disposal Laws En disposer conform ment aux lois sur l limination de d chets Maneje de Acuerdo con las Leyes de Deshace www lamprecycle org or call1 800 748 5070 INFORMACI N IMPORTANTE DE SEGURIDAD Luminario no se puede utilizar con un atenuador de intensidad Este luminario esta dise ado para uso al interior SOLAMENTE y no debe ser utilizado en reas con ventilaci n limitada ni temperaturas altas Luminario debe ser conectado a una fuente el ctrica nominal de 120 Voltios 60 Hz Cualquier otra conexi n invalidara la garant a Siempre utilice el mismo vataje y el tipo de l mpara incluida o specificada para el luminario Incumplimiento invalidara la garant a Este luminario esta destinado para ser conectado a una caja de ensambladura no proporcionada correctamente instalada listada UL puesta a tierra y debe ser instalada seg n c digos del NEC y locales de construcci n ADVERTENCIA gt RIESGO DE DESCARGA ELECTRICA La corriente el ctrica de su casa puede causarle una descarga el ctrica dolorosa o una lesi n seria a menos que se use adecuadamente Para su
8. caja de lambrado y alimente los alambres de suministro por el agujero de centro coloque con los Tornillos instalados alineados verticalmente despu s de montaje e roscas mirando hacia afuera Asegure usando Tornillos 8 32x1 1 2 4 proporcionados Vea el Fig 3 Para instalar el Espaciador de Sobrecielo alinee el agujero y la ranura en el Espaciador de Sobrecielo 3 con el agujero y la ranura en la parte trasera del Canal 6 el reborde del Espaciador de Sobrecielo no deber mirar el Canal inserte los alambres del luminario a traves de ranura del Espaciador de Sobrecielo apropiado y asegure con Tornillo 48 32 x 1 1 4 5 proporcionado Repita para el segundo Espaciador de Sobrecielo Vea Fig 4 PRECAUCI N EN LA OPERACI N DEI LUMINARIO Y DEL ALAMBRADO Conecte el luminario a alambres de suministros clasificado a por lomenos 90 C 194 No use el luminario en circuitos con atenuadorde intensidad PARA CONEXI N APROPIADA COLOQUE CAPUCH N DE LAMBRES SOBRE ALAMBRES GIRE HACIA SU DERECHA HASTA QUE QUEDE APRETADO 5 Para alambrar el Canal Con la electricidad apagada conecte el alambre de suministro negro al alambre negro del canal Conecte el alambre de electricidad negro al alambre del luminario con rayas negras entonces conecte el alambre de suministro de electricidad blanco al alambre del luminario con rayas blancas Ponga a tierra el luminario conectando el alambre verde del luminario al alambre de sumini
9. ente l installation veuillez lire attentivement ces directives y gu rdelas para futura referencia et les conserver pour r f rence ult rieure Fecha Instalada Date de l installation Protect yourself Before installing read these instructions carefully and save them for future reference Date Installed Page 1 U212144T_Rev B 05 06 INSTALLATION FIGURES FIGURAS DE LA INSTALACI N FIGURES D INSTALLATION REQUIRED TOOL HERRAMIENTAS REQUERIDAS OUTILS REQUIS Figure 1 FIXTURE PARTS LIST O Description Quantity 1 Mounting Plate Ln 2 Screws 8 32x1 1 8 CANOPY steam Screw 8 32 x 1 1 2 Screw 8 32 x 1 1 4 Channel Cover Ball Nut Wirenut loco Finial rinsar 12 End Cap 13 Diffuser sistema Contained in Part Packs Lamps amp Mounting Hardware Included LISTA DE EMBALAJE Descripci n Cantidad 1 Placa de Montaje n se 2 Tornillos 32x1 1 8 aaeeea Espaciador de Sobrecielo a Tornillo de 8 32 x 1 1 2 nassaan Tornillo de 8 32 x 1 1 4 nassen Figure 2 Figure 3 Cubierta del Canal Tuerca de Bola conc Capuch n de Alambres Rinia Serre pias 11 L mpara ccoo 12 Tapa de Extremo scce 13 DITUSO lia ina Contenido en el Paquete de Piezas 3 4 5 6 7 8 9 10 L mparas y Herraje para Montaje Incluidas LISTE
10. pas employer de produits nettoyants base d alcool Pour la disponibilit des pi ces de rechange contacter le soutien technique ou visiter lightahome com VA LITHONIA LIGHTING An lt ScuityBrands Company Consumer Products Acuity Lighting Group Inc One Lithonia Way Conyers GA 30012 www lightahome com www lithonia com Page 6 VA LITHONIA LIGHTING INSTALLATION INSTRUCTIONS INSTRUCCIONES DE INSTALACION DIRECTIVES D INSTALLATION CYLINDER Y VANITY Vanity 2 14W 2 21W or 2 28W 3000K T5 Lamp Vanidad 2 L mparas 3000KT5 de 14 21 o 28 vatios Vanity 2 Lampes T5 14W 21W ou 28W 3000K Model Numbers N meros de Models Num ros des mod les 11802RET5 BN Brushed Nickel 11803RET5 BN Brushed Nickel 10804RE75 BN Brushed Nickel Fixture can be mounted to wall vertically horizontally or at any other desired position El luminario puede ser montado a la pared verticalmente horizontalmente o en cualquier otra posici n deseada L appareil peut tre install au mur la verticale l horizontale ou toute autre position BLIGHTAHOME com Visit lightahome com to find complementary fixtures and much more e Customer Support e Energy Saving Tips e Product Instruction Sheets e Glossary of Lighting Terms e Our Complete Product Catalog e Product Specifications Prot jase Antes de instalar lea estas Pour votre propre protection Avant de proc der instrucciones cuidadosam
11. r les conducteurs par la rainure sur le pavillon appropri et fixer l aide de la vis 8 32 x 1 1 4 5 fournies R p ter la proc dure pour le deuxi me pavillon de recouvrement Voir la fig 4 MISE EN GARDE POUR LE C BLAGE ET LE MODE D EMPLOI DE L APPAREIL Connecter l appareil des fils d alimentation calibr s pour au moins 90 C 194 F Ne pas utiliser cet appareil sur un circuit de gradation de l clairage POUR ASSURER UN BON RACCORDEMENT METTRE LE CAPUCHON SUR LES FILS ET TOURNER DANS LE SENS DE ROTATION HORAIRE JUSQU CE QUE LA CONNEXION SOIT SOLIDE 5 Pour c bler la t le en U Le courant tant coup relier le fil noir d approvisionnement au fil noir de la Manche relient alors le fil blanc d alimentation d nergie au fil ray blanc de montage Montage au sol en reliant le fil vert de montage au fil de cuivre nu d approvisionnement Note si le c blage de l alimentation ne comporte pas un fil de terre consulter votre code d lectricit local et v rifier les m thodes conformes de mise la terre Connecter le fil noir d alimentation au fil ray noir de l appareil puis le fil blanc d alimentation au fil ray blanc de l appareil Ranger les fils dans la bo te de jonction 6 Placer le pavillon de recouvrement 3 sur la plaque de montage 1 guider les filets de vis pour qu ils ressortent pas les trous du pavillon Fixer l aide des fa teaux 10 7 Installer les lampes
12. s l mpara s defectiva s Verifique que el luminario este alambrado apropiadamente Verifique que el luminario este conectado tierra correctamente El voltaje de la l nea en el luminario este correcto Si requere ayuda adicional contacte Consumer Products Technical Support al 800 748 5070 Reemplazo del alastro tiene que ser hecho por un electricista calificado regado o polvos virutas de acero o papel abrasivo Para disponibilidad de piezas de repuesto p ngase en contacto con Soporte T cnico o visite lightahome com Page 5
13. stro de cobre descubiert Si el alambrado de casa no incluye un alambre de conexi n a tierra consulte su c digo el ctrico local para m todos aprobados para poner a tierra Meta los alambres en la caja de ensambladura Coloque el Espaciador de Sobrecielo 3 sobre Placa de Montaje 1 alinee las roscas del tornillo para sobresalir por los agujeros en el Espaciador de Sobrecielo Asegure con Finials 10 Instale las L mparas 11 insertando las clavijas de l mpara en la ranura encima de enchufes y gire las L mparas hasta que hagan clic 8 9 Encienda la electricidad en la caja de cortacircuitos o fusibles para verificar el xito de la instalaci n Ensamblaje del Difusor 13 Con el extremo abierto del Difusor mirando hacia la L mpara posici n el Difusor 13 sobre las L mparas y deslice del reborde de la Tapa de Extremo Asegure el Difusor 13 asegurando segunda Tapa de Extremo en el extremo opuesto del Canal Para limpiar el luminario p sele un trapo suave Limpie el Difusor con agua y un jab n suave No use materiales abrasivos como almohadillas o polvos de restregar virutas de acero o papel abrasivo No limpie con alcohol Gu a de Localizaci n de Aver as Si este luminario falla de operar apropiadamente use la siguiente gu a para diagnosticar y corregir el problema Verifique que la L mpara usada es la correcta Asegure que la l mpara este asentada correctamente en el enchufe Reemplace la
14. t pr senter des rebords coupants pour viter toute blessure porter des gants lorsqu on manipule le luminaire Garder les petites pi ces hors de la port e des enfants et d truire le mat riel d emballage MISE EN GARDE RISQUE D INCENDIE Les fils d alimentation doivent convener pour 90 C GUIDE D TAILL 1 Retirer les composants de l appareil et tout sac de pi ces fourni S assurer que toutes les pi ces sont comprises Voir la fig 1 D visser un embout glisser et retirer le diffuseur et enlever les deux lampes Enlever le mat riel d emballage Avertissement Veuillez vous d barrasser du mat riel d emballage de mani re s curitaire NOTE Couper le courant lectrique au fusible ou au disjoncteur 2 Pr parer la plaque de montage 1 pour l installation en vissant les deux vis 2 dans la plaque de montage tel qu illustr la fig 2 3 L lectricit coup e au panneau disjoncteur ou au fusible rapprocher la plaque de montage 1 de la bo te de jonction et acheminer les fils d alimentation par le trou central placer l unit avec les vis install es align es la verticale apr s le montage et les filets face l ext rieur Fixer l aide des vis 4 fournies Voir la fig 3 4 Pour installer le pavillon de recouvrement aligner le trou et la fente du pavillon 3 sur la rainure au dos de la t le en U 6 le rebord du pavillon doit tre du c t oppos la t le en U entre
15. water Do not use abrasive materi als such as scouring pads or powders steel wool or abrasive paper Do not clean with alcohol Trouble Shooting Guide If this fixture fails to operate properly use the guide below to diagnose and correct the problem Verify that correct lamp is used Make sure lamp is properly seated in socket Replace defective lamp s Verify that fixture is wired properly Verify that fixture is grounded correctly The line voltage at the fixture is correct If further assistance is required contact Consumer Products Technical Support at 800 748 5070 Ballast replacement must be done by a qualified electri cian For availability of replacement parts contact Technical Support or visit Learn to light your home like a pro A LIGHTAHOME com Page 4 GU A DE PASO A PASO 1 Remueva los componentes del luminario y paquete s de piezas Compruebe esto todas las piezas est n incluidas Vea Figura 1 Desatornille una tapa de extremo y deslice hasta sacar el difusor y remuevas ambas l mparas Remueva el material de embalaje Advertencia Deseche los materiales de embalaje con seguridad NOTA Apague la electricidad en la caja de cortacircuitos Prepare la Placa de Montaje 1 para montaje instalando Tornillos 8 32x1 1 8 2 en la Placa de Montaje como mostrado en la Fig 2 Con la electricidad apagada en la caja de cortacircuitos coloque la Placa de Montaje 1 cerca de la
Download Pdf Manuals
Related Search
Instructions instructions synonym instructions not included movie instructions for 1040 2024 instructions for form 8962 instructions brp instructions meaning instructions in spanish translation instructions for 1040 instructions unclear meme instructions for schedule c instructions for form ss-4 instructions for form 941 instructions for form 720 instructions for 1040 2023 instructions for form 8949 instructions for box 12 on w2 instructions for form 1040 instructions for submitting certain i-589 instructions synonyme instructions to candidates
Related Contents
Manuale d`Installazione e d`Uso Manuel d`Installation et Utilisation INSTRUÇÃO SUPLEMENTAR - IS EPS User Manual 9 CUP PREMIUM ALKALINE PITCHER BGV C1 BGV D8 igvw SQ P2 D8 Plus EN 61508 SIL 1 The XSB System Version 2.4 Volume 1: Programmer`s Manual Téléchargez les textes des invités. Driver risk assessment system and method employing selectively Samsung FX2490HD Uporabniški priročnik Copyright © All rights reserved.
Failed to retrieve file