OWNER`S MANUAL

image

Contents

1. SW 10 9 9 5 7 9 6 5 4 7 n a Mounted on pump 1 2 DW M 11 3 9 4 7 6 25 45 feet DW 9 2 8 1 6 8 5 8 5 0 4 3 3 4 2 6 25 95 feet SW 17 7 15 1 12 4 9 7 7 4 n a Mounted on pump 3 4 DW M 14 7 12 3 9 7 25 45 feet DW 9 8 8 9 7 1 6 1 5 3 4 4 3 5 2 9 25 95 feet SW 19 9 16 8 14 1 11 8 8 8 n a Mounted on pump 1 DW M 16 2 13 5 11 0 25 45 feet DW 10 5 9 3 8 0 7 2 6 2 5 3 4 5 3 4 25 95 feet SW Shallow well DW M Deep well medium DW Deep well operating near water Install a proper fused disconnect switch in the line and 7 You have completed the first priming cycle consisting of steps 3 to 6 This make certain the wiring is adequately sized and well insulated Undersized process will have to be repeated from 2 to 6 times depending on the length wire between the motor and the power source will adversely limit the starting of your suction line approximately one priming cycle for every 5 ft of suction and load carrying abilities of the motor Minimum wire sizes for motor branch line You will know when to stop because the pump will begin to pump circuits are recommended see Table 2 For added safety the pump and water continuously motor should be grounded to the well casing if metal or the ground in the 8
2. 25 13 7 m PP 37 34 27 23 20 17 13 11 25 22 8 m PPP 75 64 53 45 33 n a Montado en la bomba 1 PP M a m z 61 51 42 z 25 13 7 m PP 40 35 30 27 23 20 17 13 25 22 8 m PPP Pozo Poco Profundo PP M Pozo Profundo o Mediano PP Pozo Profundo cumplir con el C digo El ctrico Nacional NEC y con cualquier c digo y CARGADO ordenanza local Contrate los servicios de un electricista con licencia AVISO RIESGO DE DESCARGA EL CTRICA e Cableado Un electricista deber a hacer el cableado y conectar el servicio Nota Usted necesitar suficiente agua para llenar la linea s de succi n y el cuerpo de la bomba El tiempo de cargado depende de la distancia entre la fuente de agua y la bomba de 5 a 15 min gt TZ el ctrico a la bomba El interruptor de presi n es cableado al motor en la f brica y el voltaje al cual ha sido cableada la bomba est indicado en un r tulo en la parte posterior del motor Aseg rees que el motor est cableado para el mismo voltaje que el suministro el ctrico Vea en la placa de la marca del motor o interior de la cubierta del terminal las instrucciones de cambio de voltaje La l nea de energ a debe conectarse a los terminales del interruptor de presi n marcados con Line o L nea Fig 2 Se recomienda que se derive un circuito independiente del tablero de distribuci n a la bomba Debe usarse un circuito con pro
3. 11 Llene la tuber a de succi n con agua antes de conectarla a la bomba Usted h V lvula de Alivio de Presi n Se recomienda se instale una v lvula de necesitar aproximadamente un litro de agua por cada 3 pies de l nea de seguridad de desfogue de presi n en alg n punto en el sistema de agua succi n Aseg rese que su ubicaci n sea cerca de la descarga de la bomba en un e Y rea con drenaje adecuado Aseg rese de dirigir la v lvula de tal manera Nota Si usted no puede llenar la l nea de succi n por favor siga las que cualquier descarga de agua no moje los dispositivos el ctricos instrucciones a continuaci n para una v lvula de chequeo en la l nea E 12 Siga los pasos del 1 al 5 Si dentro de 2 minutos no se bombea agua OPERACION continuamente apague la bomba Saque el tap n de cargado Repita los A AVISO NO OPERAR LA BOMBA ANTES DE CARGARLA EL SELLO Y EL PROPULSOR PODRIAN DANARSE PERMANENTEMENTE pasos del 3 al 5 Si esto no da resultados apague la bomba y revise que no haya fugas en la linea de succi n TABLA 2 LONGITUD M XIMA DEL CABLE PIES Fig 2 Conexiones El ctricas MOTOR CALIBRE DEL ALAMBRE AWG RCA HP Volt 0 25pies 50 pies 100 pies 150 pies 200 pies de energia 115 14 14 12 10 8 1 2 lalala lo 230 14 14 14 14 14 A 115 14 14 10 8 8 3 4 230 14 14 14 14 12 Interruptor Tierra 115 14 12 10
4. L nea de Servicio la l nea de servicio debe conectarse como se muestra en la Fig 4a b c d El di metro de la l nea de servicio est totalmente determinado por la cantidad de agua que se necesita y la longitud de la tuber a La tuber a elegida debe tener el di metro suficiente para que las p rdidas por la fricci n determinadas en la Tabla 3 Tabla de P rdidas por Fricci n nunca excedan 20 pies 6 metros de presi n A AVISO PRECAUCIONES ELECTRICAS Todo cableado conexiones el ctricas y sistemas de contacto a tierra deben o oa g ae Respiradero Fig 1b Instalaci n para Pozo Profundo 25 pies 7 5 m y mas profundo Para una aplicaci n espec fica vea las instrucciones provistas con el juego del inyector Inyector _ V lvula de pie TABLA 1 RENDIMENTO PROFUNDIDAD EN METROS as 30 Jas 6a 7s 61 94 122 102 163 213 20a PRESION M NIMA POS DE INYECTOR INYECTOR INSTALACI N CON UNA TUBER A SIMPLE PARA POZO DE POCA PROFUNDIDAD INSTALACI N CON UNA TUBER A DOBLE PARA POZO PROFUNDO PPP 41 36 30 25 18 n a Montado en la bomba 1 2 PP M e 43 36 29 an 25 13 7 m PP 35 31 26 22 19 16 13 10 25 22 8 m PPP 67 57 47 37 28 n a Montado en la bomba 3 4 PP M a m 56 47 37
5. 25 13 7 m DW 35 31 26 22 19 16 13 10 25 22 8 m SW 67 57 47 37 28 n a Mont sur la pompe 3 4 DW M 56 47 37 25 13 7 m DW 37 34 27 23 20 17 13 11 25 22 8 m SW 75 64 53 45 33 n a Mont sur la pompe 1 DW M 61 51 42 25 13 7 m DW 40 35 30 27 23 20 17 13 25 22 8 m SW Puit de surface DW M Puits de profondeur moyenne DW Puits profond AX AVERTISSEMENT PRECAUTIONS LECTRIQUES Tous cablage connexions lectriques et mise a la terre des systemes doivent se conformer au Code National d Electricit NEC et aux codes et ordonnances locaux Employez un lectricien autoris A AVERTISSEMENT RISQUE DE CHOC ELECTRIQUE e C blage Il est re command qu un lectricien effectue le c blage et le raccord du service lectrique la pompe Le manostat est branch en usine au moteur et sa tension de c blage est indiqu e sur un autocollant au dos de la pompe Veiller ce que cette tension soit la m me que celle du courant d alimentation V rifier les directives pour une modification de la tension sur la plaque signal tique du moteur ou l int rieur du couvercle du terminal Les lignes de courant de secteur seront connect es aux bornes du manostat marqu es LINE secteur Voir Fig 2 Nous vous recommandons galement d utiliser un circuit ind p
6. 0 23 11 24 40 7 58 1 98 0 95 0 27 12 28 60 8 85 233 110 0 32 14 38 00 11 80 3 10 1 46 0 43 16 48 60 15 10 3 96 1 87 0 55 18 60 50 18 70 493 233 0 69 20 73 50 22 80 6 00 2 83 0 84 Perte de hauteur totale de charge en m tres caus e par la friction par 100 m tres de conduite Diam tre nominal de conduite 20mm 25mm 40mm 50mm litres min 15 3 70 1 15 0 30 0 13 20 5 33 1 64 0 43 0 19 25 7 14 2 18 0 56 0 27 30 13 50 4 13 1 08 0 49 35 16 30 5 00 1 31 0 61 40 23 50 7 30 1 90 0 88 0 25 45 28 30 8 74 2 31 1 07 0 29 50 34 20 10 60 2 79 1 32 0 38 55 40 70 12 60 3 32 1 56 0 46 60 48 10 14 90 3 92 1 85 0 54 65 55 70 17 30 4 54 2 15 0 63 70 63 80 19 70 5 20 2 46 0 73 75 72 20 22 40 5 89 2 78 0 83 INSTALLATIONS CARACTERISTIQUES R servoir Bouchon de 90 d amorcage Soupape de retour Soupape a de contr le 2 O Sa Manostat R servoir Bouchon d amorcage Soupape de retour Manostat ch Soupape 78 2 KI de contr le ony Ve amp e Vidange 3 Bouchon de vidange Soupape D Tuyau d aspiration de retenue en Bouchon de vidange ligne Tuyau d vent ee Tuyau d aspiration Garniture d tanch it Puits Tuyau d vent Clapet de pied Garniture d tanch it Puits Fig 4b PUITS PEU PROFOND Fig 4a PUITS PEU PROFOND AVEC CLAPET DE PIED AVEC
7. 7 soapy water and slip it onto the shaft with the carbon ring towards the ceramic seat Replace the impeller 6 and the diffuser 4 o Aba Reconnect the tubes to the casing and to the pressure switch Reconnect the power 9 Prime pump start check for leaks TROUBLESHOOTING a Motor will not start 1 No power to pressure switch due to blown fuses open switches or loose connections Fig 3 Pe oe opg 6 Replace the casing 2 making sure the gasket is not damaged and is in place 2 Pump pressure switch not closed b Pump fails to deliver water 1 Pump not completely primed 2 Suction lift is too great 3 Foot valve is not submerged buried in mud or plugged 4 Restrictor valve is fully closed c Pump loses prime 1 Air leaks in suction line 2 Well draws down too far and requires a tailpipe 3 Faulty foot valve d Pump delivers water but not at rated capacity 1 Leaks in suction or discharge line 2 Foot valve suction line impeller or nozzle are partially plugged 3 Suction lift is greater than recommended 4 Improper setting of control valve on deep well units 5 Improper impeller rotation or low speed 6 Motor is wired for improper voltage 7 Low line voltage at motor e Pump starts and stops too often 1 Air leak in tank above the water level 2 Incorrect setting on pressure switch 3 Tank is water logged or incorrectl
8. 8 6 de presi n 230 14 14 14 14 12 Motor Carga Basada en una baja de voltaje aproximada de 3 14 13 Una vez que la bomba comience a bombear agua continuamente ajuste firmemente el tap n de cargado con una herramienta INSTALACI N CON TUBER A DOBLE Para pozos profundos C mo cargar y calibrar la v lvula de control de descarga Siga los procedimientos de la instalaci n de una sola tuber a Cierre la v lvula de control siguiendo el mismo procedimento que para pozos poco profundos Si la bomba est cargada adecuadamente la presi n aumentar inmediatamente Abra lentamente el control de la v lvula aproximadamente de 1 a 2 1 2 vueltas hasta que la bomba rinda la capacidad m xima como se vea desde el grifo abierto m s cercano a la bomba Contin e ajustando el control de la bomba a la vez que observa el indicador de presi n mientras la bomba bombea de tal manera que el indicador de presi n marque aproximadamente 25 psi y el flujo y la presi n est n estables DRENAJE Si la unidad est expuesta a temperaturas congelantes ser necesario drenar la bomba y el tanque Para hacer sto apague el suministro de energ a a la bomba en el panel el ctrico principal Abra una llave en el sistema de agua para aliviar la presi n Quite los tapones de drenaje y carga del casco de la bomba Quite el tap n de drenaje del tanque de presi n si est provisto con uno Deje pasar suficiente tiempo para que el sistema se
9. Fig 3 Only duly qualified persons should perform maintenance on electrical and or mechanical devices Disassembly 1 Shut off the power to the pump at the main sevice panel Open a tap in the water system to release the pressure Remove the drain 12 and prime plugs to allow the pump to drain Disconnect the tube leading to the pressure switch ak N Remove the 4 bolts 1 and remove casing 2 Pry the diffuser 4 out of the casing using two slotted screwdrivers for leverage 7 Remove cap 5 and insert a screwdriver to prevent the shaft from turning while unscrewing the impeller 6 GE motors For A O Smith motors remove rear cover and hold the shaft using a flat wrench inserted from the side through the opening in the end of the housing If the impeller cannot be turned by hand insert a flat object into the impeller vane 8 Slip the rotating seal 7 off the shaft and remove the seal plate 8 9 Remove the ceramic seal seat 9 from the seal plate Reassembly 1 Clean all the parts thoroughly before assembling 2 Lightly lubricate soapy water the rubber cap on the ceramic seal 9 and push it into the seal plate using thumbs only Make sure the smooth surface of the ceramic seat faces outwards Note If the pump will remain out of service for longer than one week the seal components must be installed dry no lubrication 3 Put the seal plate back on the motor 4 Lubricate the rotating seal
10. Once the pump begins pumping water continuously firmly tighten the distribution panel priming plug with a wrench f Pressure Gauge If a pressure gauge is supplied with the pump or if you 9 Adjust the control valve clockwise so that the flow and pressure are wish to install a pressure gauge it should be installed into the 1 4 NPT hole stable see double pipe installation instructions on the front of the casing directly beside the discharge opening a i 10 If the pump does not draw water within 8 tries shut it off and check for g Air Volume Control If a non diaphragm tank is used in the pressure suction leaks system an air volume control must be used to maintain an air cushion in the pressure tank If not air in the tank will gradually be absorbed by water causing the tank to water log and the pump to short cycle This greatly a i p a shortens the life of the motor An air volume control will provide the right air 11 Fill suction pipe with water prior to connecting piping to pump You will need water ratio and prevent water logging Refer to pressure tank owner s manual approximately 1 liter of water for every 3 ft of suction line for instructions Note If you are unable to fill the suction line please use the directions above for an inline check valve Using a foot valve SINGLE PIPE INSTALLATION h Pressure Relief Valve A high pressure safety relief valve is recommended to be installed at some point in
11. Ouvrir compl tement le robinet de contr le rotation dans le sens anti horaire 3 Verser de l eau propre dans l orifice situ sur le dessus du bo tier et o sera install ult rieurement le bouchon d amorgage orifice d amorgage jusqu ce que l eau commence sortir 4 Installer le bouchon d amorgage fourni et serrer la main 5 Mettre la pompe en marche Si celle ci est munie d un robinet visible il est possible que vous observiez un refoulement de courte dur e 5 10 secondes 6 Faire fonctionner la pompe pendant 2 minutes puis l arr ter Retirer le bouchon d amorgage 7 Vous avez termin le premier cycle d amorcage qui consiste des tapes 3 6 Ce processus devra tre r p t de 2 6 fois selon la longueur de votre conduite d aspiration environ un cycle d amorcage pour chaque longueur de 5 pieds de conduite d aspiration Vous interrompez le processus quand la pompe commence pomper de l eau de fa on continue 8 ce moment bien serrer le bouchon d amorgage au moyen d une cl 9 Ajuster le robinet de contr le dans le sens anti horaire pour assurer la stabilit du d bit et de la pression voir les instructions d installation conduite double Si la pompe ne pompe pas d eau apr s 8 essais couper son fonctionnement et v rifier la tuyauterie d aspiration afin de s assurer qu il n y a aucune fuite Utilisation d un clapet de pied INSTALLATION CONDUITE UNI
12. SOUPAPE DE RETENUE EN LIGNE S Cy ey ss R servoir NA Soupape Ss Manostat Coude de 90 Vidange Bouchon d amorcage Manostat Soupape de contr le Bouchon de vidange Tuyau d aspiration Tuyau d vent Garniture d tanch it Puits Clapet de pied Fig 4c PUITS PEU PROFOND R SERVOIR EN LIGNE AVEC CLAPET DE PIED Coude de 90 Soupape de contr le Bouchon d amorcage Tuyau de pression de retour Tuyau d aspiration Tuyau d vent Garniture Puitgd tanch it Injecteur Clapet de pied Fig 4d PUITS PEU PROFOND SYST ME MONT SUR LE R SERVOIR INSTALLATION CONDUITE DOUBLE AVEC CLAPET DE PIED PIECES DE RECHANGE 13E H J K 11H Identifiant du Codes de commande des pi ces de rechange par num ro de mod le Description groupe de trousse 1 2 hp 1 Corps d injecteur A 305446946 305446947 2 Bec B 305446948 305446949 3 Venturi A 305446946 305446947 4 Joint d tanch it injecteur B 305446948 305446949 5 Trousse de bouchons C 305446953 6 Manom tre D 305446935 7 Ensemble de clapet F 305446951 8 Ensemble de raccordement G 305446936 de l interrupteur 9 Diffuseur 10 Roue H 305446941 305446942 11 Joint m canique l 106196221 12 Bo tier E 305446950 H 305446941 305446942 13 Joint d tanch it J 305446945 K 305446943 14 Plaque
13. TO A PRODUCT SHALL BE LIMITED IN DURATION TO THE PERIODS OF THE EXPRESSED WARRANTIES GIVEN ABOVE DISCLAIMER Any oral statements about the product made by the seller the Company the representatives or any other parties do not constitute warranties shall not be relied upon by the buyer and are not part of the contract for sale Seller s and the Company s only obligation and buyer s only remedy shall be the replacement and or repair by the Company of the product as described above Before using the user shall determine the suitability of the product for his intended use and user assumes all risk and liability whatsoever in connection therewith Some states and countries do not allow the exclusion or limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusion or limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state and country to country Contact Franklin Electric Co Inc Export Division for International Warranty Franklin Electric 400 E Spring St Bluffton IN 46714 Tel 260 824 2900 Fax 260 824 2909 106512101 Rev 1 6 10 www franklin electric com AN Franklin Electric 4 CONSIGNES DE SECURITE AVANT D INSTALLER OU D UTILISER CETTE POMPE PRI RE DE LIRE LE PR SENT GUIDE ET SUIVRE TOUTES LES R GLES DE S CURIT ET INSTRUCTIONS D UTILIS
14. WELL WITH INLINE CHECK VALVE 90 Elbow Priming Plug Pressure Switch 90 Elbow Control Valve Priming Plug Return Fig 4d DEEP WELL TANK MOUNTED SYSTEM DOUBLE PIPE INSTALLATION WITH FOOT VALVE REPLACEMENT PARTS 13E H J K 11H Kit Grouping Repair Part Order Codes by Model Number Description FH Identifier 1 2 hp 1 Injector body A 305446946 305446947 2 Nozzle B 305446948 305446949 3 Venturi A 305446946 305446947 4 Gasket injector B 305446948 305446949 5 Plugs kit C 305446953 6 Pressure Gauge D 305446935 7 Valve assembly F 305446951 8 Switch attachment set G 305446936 9 Diffuser 10 Impeller H 305446941 305446942 11 Mechanical Seal l 106196221 12 Casing E 305446950 H 305446941 305446942 13 Gasket J 305446945 K 305446943 14 Seal Plate H 305446941 305446942 15 Flinger L 305446952 16 Fastner Kit 17 Pressure Switch M 305446944 18 Motor N 305446955 305446956 305446957 19 Base Assembly P 305446960 tlitems with like identifiers are sold packaged together Fastener kit 16L is a complete set of the hardware used to assemble the pump As a convenience kit A B E H K contain the fasteners needed for the reassembly of its components LIMITED WARRANTY THIS WARRANTY SETS FORTH THE COMPANY S SOLE OBLIGATION AND PURCHASER S EXCLUSIVE REMED
15. drene por completo antes de volver a colocar los tapones MANTENIMIENTO A AVISO RIESGO DE DESCARGA ELECTRICA Antes de darle servicio a equipos operados por motor cortae el suministro el ctrico en el panel el ctrico principal y desconecte el suministro el ctrico al motor y accesorios Utilice practicas de trabajo seguras al darle servicio al equipo a Lubricaci n La bomba no requiere lubricaci n Vea en el manual del fabricante del motor las instrucciones b Reemplazo del sello mec nico Ver Fig 3 Solamente personas debidamente calificadas deben efectuar el mantenimiento de dispositivos el ctricos y o mec nicos Desensamblaje 1 Corte el suministro de energ a a la bomba en el panel principal de servicio Para aliviar la presi n abra una llave que deje salir agua del sistema Quite los tapones de drenaje 12 y de carga para permitir que la bomba se drene Desconecte la tuber a que va al interruptor de presi n ak uN Quite los 4 pernos 1 y quite el casco 2 Para sacar el difusor 4 del casco palanquee usando 2 entornilladores ranuradaos para obtener equilibrio Quite la tapa 5 e inserte un entornillador para evitar que el eje gire mientras se desentornilla el impulsor 6 motores General Electric Para motores A O Smith quite la cubierta posterior y sujete el eje con una llave plana insertada por el costado a trav s del orificio en la parte posterior del casco Si no se puede girar
16. installations doivent avoir un clapet de pied et une soupape de retenue dans le tuyau d aspiration c Raccordement de la pompe au r servoir La conduite de refoulement de la pompe au r servoir devrait tre aussi courte et directe que possible et son diam tre devrait tre le m me que celui de l orifice de refoulement de la pompe Il ne faudrait jamais installer un clapet de retenue entre la pompe et le r servoir d Branchement d eau Il faudrait raccorder le branchement d eau comme Pindiquent les figures 2a b c ou d Le diam tre de la conduite de branchement d eau est en rapport direct avec le volume d eau requis et la longueur de la conduite elle m me Le diam tre de la conduite choisie devrait tre assez grand pour que la hauteur de la perte de charge tablie l aide du tableau 3 Diagramme de perte de charge ne d passe jamais plus de 20 pieds 6 m Fig 1b Installation pour un puits profond 25 pieds 7 5 m tres et plus Pour toute utilisation sp cifique consulter les instructions fournies avec l injecteur Injecteur Clapet de pied TABLEAU 1 RENDEMENT PROFONDEUR EN METRES INJECTEUR INSTALLATION A TUYAU SIMPLE POUR PUITS DE SURFACE PRESSION MINIMUM ADJ INJECTEUR INSTALLATION A TUYAU DOUBLE POUR PUITS PROFOND SW 41 36 30 25 18 n a Mont sur la pompe 1 2 DW M 43 36 29
17. l appareil au d tail et uniquement pendant la p riode pendant laquelle l acheteur initial habite le m me endroit o l appareil a t install la premi re fois Toute demande de service sous cette garantie doit tre adress e au marchand de produits Franklin Electric o l appareil a t achet d s que possible apr s la d couverte du d faut pr sum Franklin Electric prendra alors des mesures correctives dans un d lai aussi court que raisonnablement possible Franklin Electric peut sa discr tion et apr s l inspection par un repr sentant autoris de l entreprise ou apr s r ception par du produit l usine de Franklin Electric remplacer ou r parer tout produit couvert par cette garantie Aucun remplacement ni r paration n est possible avant l inspection du produit L acheteur assume tous les frais de transport ainsi que les frais d enl vement et de r installation de l appareil ou les frais d installation d un appareil de rechange LA GARANTIE PRESENTE REMPLACE TOUTE GARANTIE NON DAT E OU PORTANT UNE DATE ANT RIEURE TOUTE GARANTIE IMPLICITE D TENUE PAR L ACHETEUR INCLUANT LA GARANTIE DE QUALIT MARCHANDE ET D APTITUDE UN USAGE PARTICULIER NE S APPLIQUERA QUE PENDANT LA P RIODE DE GARANTIE APPLICABLE Certains tats ne permettent aucune limitation de la dur e d une garantie implicite La restriction ci dessus pourrait donc ne pas s appliquer votre cas FRANKLIN ELECTRIC NE SERA EN AUCUN CAS RESPONSA
18. nozzle may be used For vertical lifts of 25 ft 7 5m or less install as a shallow well unit Fig 1a and for vertical lifts beyond 25 ft 7 5m install as a medium depth deep well or as a deep well unit Fig 1b In offset installations friction losses in the suction pipe must be taken into consideration refer to Table 3 Friction Loss Chart This pump is not tested for use in swimming pool areas Less at high altitudes INSTALLATION a Pump Location The pump should be installed in a clean dry and ventilated location which provides adequate room for servicing and protection from freezing temperatures It should be bolted to a good foundation preferably concrete and provided with adequate drainage Locating the pump as close as possible to the water source reduces the friction in the suction pipe and will give maximum capacities Injector Fig 1a Shallow Well Installation 25 ft 7 5M max Foot Valve El WJC JPC Convertible Jet Pump b Suction amp Pressure Pipe lt is recommended that only new clean 1 1 4 pipe or hose be used If the pump is installed any appreciable distance away from the source of water the suction pipe should be increased to 1 1 2 Horizontal lengths of pipe must gradually slope upwards from the source of water to the pump to avoid air pockets in the line Thread compound should be used on all pipe joints and connections should be thoroughly tightened A foot valve must be ins
19. the water system Ensure its location is near 12 Follow steps 1 to 5 above If within two minutes water is not being pumped the discharge of the pump in an area with adequate drainage Be sure to continuously stop the pump Remove priming plug Repeat steps 3 to 5 direct the valve so that any water flow could not spray towards any electrical above If this does not work stop the pump and check the suction line for devices leaks 13 Once the pump begins pumping water continuously firmly tighten the OPERATION priming plug with a wrench WARNING DO NOT RUN THE PUMP BEFORE PRIMING IT SINCE THE DOUBLE PIPE INSTALLATION SEAL AND IMPELLER COULD BE PERMANENTLY DAMAGED Deep Well Application Priming and setting the discharge control valve PRIMING eae oh Follow the single pipe installation procedures Close the control valve Note You will need enough water to fill the suction line s and casing Priming clockwise rotation If the pump is properly primed pressure will build up time depends on distance from water source to pump 5 15 minutes immediately Open the control valve slowly approx 1 to 2 1 2 turns until the Using an inline check valve pump delivers maximum capacity as observed from an open tap nearest the 1 Open discharge valve on service line and nearby tap to monitor water flow pump Observing the pressure gauge while the pump is pumping continue to adjust the control valve so that the pressure gauge reads approx 25 PSI and fl
20. 2 Le niveau d eau baisse trop dans le puits ce qui n cessite un tuyau d aspiration 3 Un clapet de pied d fectueux d La pompe refoule l eau a un d bit insuffisant 1 Fuites dans les conduites d aspiration ou de refoulement 2 Obstruction partielle du clapet de pied de la conduite d aspiration de la roue ou de la buse 3 Hauteur d aspiration plus lev e que recommand e 4 R glage incorrect de la soupape de contr le sur un puits profond 5 Rotation incorrecte ou r gime trop faible de la roue de turbine 6 Le moteur est c bl pour un voltage incorrect 7 La compagnie d lectricit fournit un voltage trop bas pour le moteur e D marrage et arr t trop fr quent de la pompe 1 Fuite d air dans le r servoir au dessus du niveau de l eau 2 Mauvais r glage du manostat 3 Le r servoir est satur d eau ou incorrectement pressuris pour l application choisie 4 Le clapet de pied fuit ou reste ouvert TABLEAU 3 DIAGRAMME DE PERTE DE CHARGE POUR CONDUITE EN PLASTIQUE Pour de la tuyauterie en acier galvanis doubler les chiffres ci dessus Perte de hauteur totale de charge en pieds caus e par la friction par 100 pieds de conduite Diam tre nominal de conduite Gal U S min 3 4 po 1po 11 4 po 1 2 po 2 po 4 3 74 1 15 0 30 0 14 5 5 66 1 75 0 46 0 22 6 7 95 2 45 0 65 0 31 7 8 9 10 60 3 25 0 86 0 41 13 50 4 16 1 10 0 52 16 80 5 17 1 35 0 65 10 20 40 6 31 1 67 0 79
21. AN Franklin Electric SAFETY WARNINGS BEFORE OPERATING OR INSTALLING THIS PUMP READ THIS MANUAL AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS A SAFETY READ THIS MANUAL BEFORE INSTALLING OR OPERATING THE PUMP CAUTION Review instructions before operating WARNING ELECTRICAL PRECAUTIONS All wiring electrical connections and system grounding must comply with the National Electrical Code NEC and with any local codes and ordinances Employ a licensed electrician FOR DUAL VOLTAGE MOTORS Voltage change instructions are located on motor label or on wiring access cover A WARNING RISK OF ELECTRICAL SHOCK Have an electrician provide electrical power to motor A ground fault interrupter GFI protected circuit is recommended for use with any electrical device operating near water For recommended cable size see Table 2 Maximum Wire Length Motor must be grounded and terminal cover in place to reduce electrical shock hazard Keep motor operating area as dry as possible Always disconnect power before servicing Not investigated for use in swimming pool area APPLICATION The convertible jet pump is ideal for the supply of fresh water to rural homes farms and cabins that have suction lifts down to 90 ft This pump may be installed as a shallow well unit with the injector mounted to the casing For a deep well unit the injector is mounted in the well and either combination of venturi or
22. ATION A SECURITE LIRE ATTENTIVEMENT LES AVIS DE SECURITE SE TROUVANT DANS LE PRESENT MANUEL ET SUR LA POMPE A CAUTION Passez les instructions en revue avant d utiliser la pompe A MISE EN GARDE PRECAUTIONS ELECTRIQUES Tous cablage connexions lectriques et mise a la terre des syst mes doivent se conformer au Code National d Electricit NEC et aux codes et ordonnances locaux Employez un lectricien autoris A POUR LES MOTEURS BI TENSION Les instructions pour changer la tension sont sur l tiquette du moteur ou sur le couvercle d acc s aux files lectriques MISE EN GARDE RISQUE DE CHOC LECTRIQUE Faire appel un lectricien pour l alimentation lectrique du moteur Un disjoncteur de fuite la terre DDFT pour prot ger le circuit est recommand avec tout appareil lectrique fonctionnant proximit de l eau Pour la taille de c ble recommand e voir le Tableau 2 Longueur de c ble maximale Le moteur doit tre muni d un conducteur avec mise la terre et le couvercle des bornes doit tre en place afin de r duire le risque de secousse lectrique Garder la zone de travail aussi s che que possible Vous assurer de toujours couper l alimentation lectrique avant tout entretien Cette pompe n a pas t test e pour tre utilis e autour d une piscine APPLICATION La pompe injecteur convertible est id ale pour l approvisionnement en eau potable des maisons de ca
23. BLE DES DOMMAGES CONSECUTIFS OU INDIRECTS Certains tats ne permettent pas l exclusion des dommages cons cutifs ou indirects ou des restrictions quant ces dommages La disposition ci dessus pourrait donc ne pas s appliquer votre cas La garantie pr sente ne couvre aucun produit ayant subi de la n gligence des modifications un accident de l abus ou un mauvais usage une installation inappropri e du vandalisme des troubles publics ou une catastrophe naturelle Les seules garanties autoris es par Franklin Electric sont les garanties d crites dans la pr sente Franklin Electric n autorise aucune autre personne offrir des garanties concernant ses produits et n assumera aucune responsabilit pour toute garantie non autoris e offerte lors de la vente de ses produits LA GARANTIE PR SENTE VOUS CONF RE CERTAINS DROITS RECONNUS PAR LA LOI VOUS POURRIEZ D TENIR D AUTRES DROITS QUI PEUVENT DIFFERER SELON LES TATS Veuillez vous adresser a la section des exportations de Franklin Electric Co Inc pour des renseignements concernant la garantie internationale Franklin Electric 400 E Spring St Bluffton IN 46714 Tel 260 824 2900 Fax 260 824 2909 106512101 Rev 1 6 10 www franklin electric com AN Franklin Electric 44 ADVERTENCIAS DE SEGURIDAD LEA ESTE MANUAL Y SIGA TODAS LAS REGLAS DE SEGURIDAD ANTES DE INSTALAR U OPERAR ESTA BOMBA A SEGURIDAD LEA CUIDADOSAMENTE ESTOS MENSAJES D
24. E SEGURIDAD EN ESTE MANUAL Y EN LA BOMBA A CUIDADO Revise cuidadosamente las instrucciones antes de usarla A AVISO PRECAUCIONES ELECTRICAS Todo cableado conexiones el ctricas y sistemas de contacto a tierra deben cumplir con el C digo El ctrico Nacional NEC y con cualquier c digo y ordenanza local Contrate los servicios de un electricista con licencia A PARA MOTORES DE DOS VOLTIOS Las instrucciones por el cambio de voltio estan sobre la etiqueta del motor o la cubierta del alambrado A AVISO RIESGO DE DESCARGA ELECTRICA Haga que un electricista provea de energia al motor Se recomienda un protector de circuitos por falla de conexi n a tierra GFI en cualquier dispositivo el ctrico que opere cerca del agua Para tama os de cable recomendados vea la tabla 2 Largo m ximo del cable El motor debe estar conectado a tierra y la cubierta del terminal debe instalarse para evitar riesgos de descarga el ctrica Mantenga el rea de operaci n tan seca como sea posible Desconecte siempre el suministro el ctrico antes de darle servicio e Este producto no ha sido probado para usarse en reas de piscinas APLICACI N La bomba convertible a chorro es ideal para suministrar agua potable a viviendas rurales granjas y caba as que tienen columnas de succi n de hasta 90 pies Esta bomba puede instalarse como unidad para pozo de poca profundidad con el inyector montado en el casco Para unidades de pozo profund
25. QUE 11 Remplir d eau la conduite d aspiration avant de raccorder la tuyauterie la pompe Vous aurez besoin d environ 1 litre d eau pour chaque longueur de 3 pieds de conduite d aspiration Remarque S il vous est impossible de remplir la conduite d aspiration pri re de consulter les instructions ci dessus concernant le clapet anti retour sur conduite Suivre les tapes 1 5 ci dessus Si la pompe ne pompe pas d eau continuellement apr s 2 minutes il faut l arr ter retirer le bouchon d amorcage et r p ter les tapes 3 5 ci dessus En cas d chec arr ter la pompe et v rifier la conduite d aspiration afin de s assurer qu il n y a aucune fuite 10 12 13 Une fois que la pompe commence pomper de l eau de fa on continue bien serrer le bouchon d amorgage au moyen d une cl INSTALLATION CONDUITE DOUBLE Pour puits profond Amor age et r glage de la soupape de contr le de sortie TABLEAU 2 LONGUEUR MAXIMALE DES FILS EN PIEDS MOTEUR CALIBRE DES FILS AWG 4 2 115 14 14 12 10 8 230 14 14 14 14 14 3 4 115 14 14 10 8 8 230 14 14 14 14 12 4 115 14 12 10 8 6 230 14 14 14 14 12 Bas e sur une baisse de voltage approximative de 3 Suivez les proc dures pour installation a conduite unique Fermez la soupape de contr le dans le sens des aiguilles d une montre Si la pompe est correctement amorc e la pression augmentera imm diatement Ouvrir l
26. Y FOR DEFECTIVE PRODUCT Franklin Electric Company Inc and its subsidiaries hereafter the Company warrants that the products accompanied by this warranty are free from defects in material or workmanship of the Company The Company has the right to inspect any product returned under warranty to confirm that the product contains a defect in material or workmanship The Company shall have the sole right to choose whether to repair or replace defective equipment parts or components The buyer should return the product to the place of purchase for warranty consideration Subject to the terms and conditions listed below the Company will repair or replace to the buyer any portion of this product which proves defective due to materials or workmanship of the Company The Company will consider products for warranty for 12 months from the date of installation or for 24 months from the date of manufacture whichever occurs first The Company shall INNO EVENT be responsible or liable for the cost of field labor or other charges incurred by any customer in removing and or affixing any product part or component thereof The Company reserves the right to change or improve its products or any portions thereof without being obligated to provide such change or improvement to previously sold products THIS WARRANTY DOES NOT APPLY TO products damaged by acts of God including lightning normal wear and tear normal maintenance services and the parts us
27. a apreciable del suministro de agua el tama o de la tuber a de succi n debe incrementarse a 1 1 2 Los tramos horizontales de la tuber a deben tener una pendiente gradual de la fuente de agua a la bomba para evitar burbujas de aire en la l nea Se debe usar compuestos para roscas en todas las uniones de la tuber a y las conexiones deben estar bien ajustadas Se debe instalar una v lvula de pie y su operaci n debe inspeccionarse debido a que las fugas evitan la operaci n apropiada del sistema Aseg rese de ubicar la v lvula de pie de tal manera que siempre est sumergida Si el pozo no puede proveer la misma cantidad de agua que la bomba succiona instale una tuber a de escape hasta 30 pies de largo entre el inyector y la v lvula de pie Al vaciarse el pozo debido a la fuerte demanda la capacidad de la bomba disminuir y el nivel del agua no caer por debajo de la v lvula de pie haciendo perder la carga de la bomba Si se usa una base al fondo del pozo o un pozo guiado instale una v lvula de chequeo junto a la aspiraci n de la bomba en lugar de la v lvula de pie Fig 4b Todas las instalaciones deben tener una v lvula de pie o de chequeo en la tuber a de succi n c Acoples de la Bomba al Tanque la tuber a de descarga de la bomba al tanque debe ser tan corta y directa como sea posible y debe ser del di metro de la tuber a de salida de la bomba Nunca se debe instalar una v lvula de chequeo entre la bomba y el tanque
28. a Fricci n por Cada 100 Pies de Tuber a Di metro Nominal de Tuber a 3 4pulg 1 1 4pulg 1 1 2pulg Gal Amer Min 3 74 1 15 0 30 0 14 5 66 1 75 0 46 0 22 7 95 2 45 0 65 0 31 10 60 3 25 0 86 0 41 13 50 4 16 1 10 0 52 16 80 5 17 1 35 0 65 20 40 6 31 1 67 0 79 0 23 24 40 7 58 1 98 0 95 0 27 28 60 8 85 2 33 1 10 0 32 38 00 11 80 3 10 1 46 0 43 48 60 15 10 3 96 1 87 0 55 18 60 50 18 70 4 93 2 33 0 69 20 73 50 22 80 6 00 2 83 0 84 P rdida de Presi n en Metros debido a Fricci n por Cada 100 m de Tuber a Di metro Nominal de Tuber a 20mm 25mm 32mm 40mm 50mm L minuto 15 3 70 1 15 0 30 0 13 20 5 33 1 64 0 43 0 19 25 7 14 2 18 0 56 0 27 30 13 50 4 13 1 08 0 49 35 16 30 5 00 1 31 0 61 40 23 50 7 30 1 90 0 88 0 25 45 28 30 8 74 2 31 1 07 0 29 50 34 20 10 60 2 79 1 32 0 38 55 40 70 12 60 3 32 1 56 0 46 60 48 10 14 90 3 92 1 85 0 54 65 55 70 17 30 4 54 2 15 0 63 70 63 80 19 70 5 20 2 46 0 73 75 72 20 22 40 5 89 2 78 0 83 INSTALACIONES T PICAS Tanque Codo de 90 Tap n de cargado Interruptor de presi n V lvula de control Tanque Codo de 90 Tap n de Interruptor cargado de presi n V lvula de Tap n de cargado Interruptor de presi n V lvula de control Tap n de drenaje Tuber a de succi n Tuber a del respiradero Sello del poz
29. a soupape de contr le lentement d environ un tour deux tours et demi jusqu ce que la capacit de la pompe atteigne son maximum un robinet ouvert proximit de la pompe En observant le manom tre tandis que la pompe fonctionne continuer d ajuster la soupape de contr le pour que la lecture sur le manom tre soit d environ 25lb po alors que le d bit et la pression demeurent stables DRAINAGE Si la pompe est expos e au gel il faut vidanger la pompe et le r servoir Pour ce faire couper l alimentation lectrique de la pompe au panneau de distribution principal Ouvrir un robinet dans le syst me d alimentation en eau potable afin d abaisser la pression Retirer les bouchons de drainage et d amorcage du bo tier de la pompe Retirer le bouchon de drainage du r servoir pression s il en poss de un Attendez suffisamment longtemps pour permettre au syst me de se drainer compl tement avant de remettre les bouchons ENTRETIEN AVERTISSEMENT RISQUE DE CHOC LECTRIQUE Avant d installer l quipement du moteur couper l alimentation lectrique au panneau de distribution principal et d brancher le circuit d alimentation lectrique du moteur et des accessoires Utiliser des proc dures de travail s curitaires pendant l installation de l quipement a Lubrification Cette pompe ne n cessite aucune lubrification Consulter le mode d emploi du fabricant du moteur b Remplacement du joint m canique Voir Fi
30. d tanch it H 305446941 305446942 15 D flecteur L 305446952 16 Trousse de fixation 17 Manostat M 305446944 18 Moteur N 305446955 305446956 305446957 19 Base P 305446960 Les articles aux identifiants similaires sont vendus emball s ensemble La trousse de fixation 16L est un ensemble complet de ferrures utilis es pour assembler la pompe Pour plus de commodit les trousses A B E H et K contiennent les attaches requises pour le reassemblage de ses composants GARANTIE RESTREINTE AUX E U Franklin Electric Co Inc Franklin Electric Co Inc garantit que ses appareils neufs sont exempts de tout d faut de mat riau et de fabrication La garantie couvre la dur e la plus courte entre une p riode de 1 an a partir de la date d installation ou de 2 ans partir de la date de fabrication UNIQUEMENT pour une installation en eau propre et potable La garantie ne couvre pas les utilisations de pompage d eau sal e ou d autres liquides corrosifs L utilisateur doit consulter et respecter les codes locaux pour toutes les applications Franklin Electric Co Inc offre d ailleurs une garantie additionnelle sur certains produits comme d crit dans la pr sente La responsabilit de Franklin Electric concernant les quipements fabriqu s par d autres fournisseurs se limite la garantie r ellement offerte Franklin Electric par ces fournisseurs La garantie ne s applique qu l acheteur initial de
31. ed in connection with such service or any other conditions beyond the control of the Company THIS WARRANTY WILL IMMEDIATELY VOID if any of the following conditions are found 1 Product is used for purposes other than those for which it was designed and manufactured 2 Product was not installed in accordance with applicable codes ordinances and good trade practices 3 Product was not installed by a Franklin Certified Contractor or 4 Product was damaged as a result of negligence abuse accident misapplication tampering alteration improper installation operation maintenance or storage nor to an excess of recommended maximums as set forth in the product instructions NEITHER SELLER NOR THE COMPANY SHALL BE LIABLE FOR ANY INJURY LOSS OR DAMAGE DIRECT INCIDENTAL OR CONSEQUENTIAL INCLUDING BUT NOT LIMITED TO INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR LOST PROFITS LOST SALES INJURY TO PERSON OR PROPERTY OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL LOSS ARISING OUT OF THE USE OR THE INABILITY TO USE THE PRODUCT AND THE BUYER AGREES THAT NO OTHER REMEDY SHALL BE AVAILABLE TO IT THE WARRANTY AND REMEDY DESCRIBED IN THIS LIMITED WARRANTY IS AN EXCLUSIVE WARRANTY AND REMEDY AND IS IN LIEU OF ANY OTHER WARRANTY OR REMEDY EXPRESS OR IMPLIED WHICH OTHER WARRANTIES AND REMEDIES ARE HEREBY EXPRESSLY EXCLUDED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT EITHER APPLIES
32. el impulsor a mano inserte un objeto plano entre las paletas del propulsor Deslice el sello rotativo 7 sac ndolo del eje y quite la placa del sello 8 Quite el asiento del sello cer mico 9 de la placa del sello o N lt 8 9 Reensamblaje 1 Limpie completamente todas las partes antes de ensamblar 2 Lubrique ligeramente con agua jabonosa la tapa de caucho en el sello de cer mica 9 y emp jelo en la plancha selladora con sus dedos pulgares solamente Aseg rese que la superficie lisa est mirando hacia el exterior NOTA Si la bomba va a estar fuera de servicio por m s de una semana entonces los componentes del sello se deben instalar secos sin lubricaci n Vuelva a instalar la placa del sello en el motor Lubrique el sello rotativo 7 con agua jabonosa y deslicelo en el eje con el anillo de carb n mirando hacia el asiento de cer mica Vuelva a instalar el impulsor 6 y el difusor 4 LS Fig 3 6 Vuelva a poner el casco 2 asegur ndose que la junta no est da ada y que est en su lugar 7 Vuelva a conectar los tubos al casco y al interruptor de presi n 8 Vuelva a conectar la electricidad 9 Cargue la bomba enci ndala revise si hay fugas GU A PARA DETECTAR PROBLEMAS a El motor no arranca 1 No llega electricidad al interruptor de presi n debido a fusibles quemados interruptores abiertos o conexiones sueltas 2 Interruptor de pr
33. endant et un cable d alimentation reliant directement le panneau de distribution a la pompe Un disjoncteur de fuite a la terre DDFT pour prot ger le circuit devrait tre utilis avec tout appareil lectrique fonctionnant proximit de l eau Installer un disjoncteur fusible appropri sur le circuit et veiller ce que le c ble soit de dimension ad quate et qu il soit bien isol Un c ble de calibre inf rieur entre le moteur et le circuit d alimentation affectera la capacit de d marrage et la puissance sous charge du moteur Un calibre minimum pour le c blage est recommand pour le c ble du circuit d alimentation Voir tableau 2 Il serait pr f rable pour ajouter encore la s curit de mettre la pompe et le moteur la masse en les branchant au tubage en acier du puits ou de les mettre la terre dans le panneau de distribution lectrique Manom tre Si un manom tre est fourni avec la pompe ou si vous d sirez en installer un il doit correspondre l orifice de Y po NPT se trouvant sur la partie avant du bo tier directement c t de l orifice de refoulement Commande du volume d air Si un r servoir sans diaphragme est utilis dans le syst me de pression il faut utiliser un r gulateur de volume d air pour maintenir un coussin d air dans le r servoir sous pression Sinon l air dans le r servoir sera graduellement absorb par l eau le r servoir pourrait alors tre noy et provoquer le fonc
34. esi n de la bomba abierto b La bomba no bombea agua 1 La bomba no ha sido completamente cargada 2 La columna de succi n es muy alta 3 La v lvula de pie no est sumergida est enterrada en barro o atorada 4 La v lvula reductora est completamente cerrada c La bomba se descarga 1 Fuga de aire en la l nea de succi n 2 El nivel de agua del pozo baja demasiado y se requiere un tubo de escape 3 V lvula de pie defectuosa d La cantidad de agua que descarga la bomba es menor que la capacidad indicada 1 Fugas en la l nea de succi n o de descarga 2 La v lvula de pie tuber a de succi n propulsor o boquilla se encuentran parcialmente atoradas 3 La columna de succi n es mayor que lo recomendado 4 Regulaci n inapropiada de la v lvula de control en unidades para pozos profundos Baja velocidad del impulsor o rotaci n incorrecta El cableado del motor es inapropiado para el voltaje Bajo voltaje en la l nea del motor e La bomba arranca y para muy seguido 1 Fuga de aire por encima de la l nea de agua en el tanque 2 Posici n incorrecta del interruptor de presi n 3 El tanque tiene demasiada agua o est cargado incorrectamente 4 La v lvula de pie tiene fugas o se ha atracado en la posici n de abierto al NO TABLA 3 TABLA DE P RDIDA DE PRESI N PARA TUBER A DE PL STICO Para tuber as galvanizadas duplique las cifras anteriores P rdida de Presi n en pies debido
35. g 3 Seulement le personnel d j entra n et qualifi devrait effectuer l entretien des quipements lectriques et ou m caniques D montage 1 Couper l alimentation lectrique de la pompe au panneau de distribution principal 2 Ouvrir un robinet dans le syst me d alimentation d eau afin de r duire la pression 3 Enlever les bouchons de drainage 12 et d amorcage afin de permettre le drainage de la pompe 4 D brancher le tube raccord au manostat 5 Enlever les 4 boulons 1 et enlever le bo tier 2 6 Soulever en pressant le diffuseur 4 hors du bo tier en utilisant 2 tournevis droits comme levier 7 Enlever le couvercle 5 et ins rer un tournevis pour emp cher l arbre de tourner pendant le d vissage de la roue de turbine 6 moteur G E Pour les moteurs de marque A O Smith enlever le couvercle arri re et tenir l arbre en utilisant une clef molette ins r e travers l ouverture l extr mit du caisson Si vous ne parvenez pas tourner la roue manuellement ins rer un objet plat dans l aube de la roue 8 Faire glisser la partie rotative du joint m canique 7 hors de l arbre et d gager la plaque d tanch it 8 9 Enlever le si ge de c ramique 9 de la plaque d tanch it Remontage 1 Bien nettoyer toutes les pi ces avant de les assembler 2 Lubrifier l g rement avec de l eau savonneuse le capuchon en caoutchouc sur le si ge de c ramique 9 et l enfoncer avec le
36. idas en cuenta por el comprador y no forman parte del contrato de compraventa La nica obligaci n del comprador y de la Empresa y la nica soluci n del comprador ser el reemplazo y o la reparaci n del producto por parte de la Empresa tal como se describe anteriormente Antes de usar el producto el usuario debe determinar si ste es adecuado para el uso que se le desea dar y el usuario asume todo riesgo y responsabilidad en conexi n con dicho uso Algunos estados y pa ses no permiten la exclusi n o limitaci n de la duraci n de garant as impl citas o la exclusi n o limitaci n por da os accidentales o consecuentes por eso la exclusi n o limitaci n anterior puede no aplicarse en este caso Esta garant a le otorga derechos legales espec ficos y usted tambi n puede tener otros derechos que varien seg n el estado o el pa s Contacte la Divisi n de Exportaci n de Franklin Electric Co Inc para informarse sobre Garant a Internacional Franklin Electric 400 E Spring St Bluffton IN 46714 Tel 260 824 2900 Fax 260 824 2909 106512101 Rev 1 6 10 www franklin electric com
37. ional information WARNING ELECTRICAL PRECAUTIONS All wiring electrical connections and system grounding must comply with the National Electrical Code NEC and with any local codes and ordinances Employ a licensed electrician WARNING RISK OF ELECTRICAL SHOCK e Wiring An electrician should be employed to do the wiring and connect the electrical service to the pump The pressure switch is wired to the motor at the factory and the voltage for which the motor is wired is indicated by a sticker on the back of the motor Make sure the motor is wired for the same voltage as the power supply Refer to the motor nameplate or inside terminal cover for voltage changing instructions The power lines should be connected to the pressure switch terminals marked line see Fig 2 It is recommended that a separate circuit be led from the distribution panel to the pump unit A ground fault interrupter GFI protected circuit should be used for all electrical devices Fig 1b Deep Well Installation 25 ft 7 5M and deeper For specific applications see instructions supplied with injector kit Injector Foot Valve TABLE 1 PERFORMANCE DEPTH IN FEET s to a5 20 25 20 30 a0 so oo 7 i A INJECTOR CAPACITY IN GALLONS PER MINUTE 30 PSI DISCHARGE PSI SETTINGS SINGLE PIPE SHALLOW WELL DOUBLE PIPE DEEP WELL INSTALLATION INSTALLATION
38. ite d aspiration et obtenir le d bit maximal il est recommand d installer la pompe aussi pr s que possible du point d eau b Tuyau d aspiration et de pression Il est recommand de n utiliser qu un tuyau ou un boyau neuf de 1 Y Si la pompe se trouve une certaine distance du point d eau il faudrait accro tre le diam tre de la conduite et se servir d un tuyau de 1 1 2 Les sections horizontales de tuyauterie seront graduellement inclin es vers le haut depuis la source d eau jusqu la pompe pour viter la formation de poches d air dans la canalisation Un mastic pour tuyau taraud doit tre utilis sur tous les joints du tuyau et les connexions doivent tre bien serr es Un clapet de pied doit tre install et v rifi pour d tecter toute fuite qui emp cherait le bon fonctionnement du syst me Disposer le clapet de pied de fa on ce qu il soit immerg en tout temps Si le puits ne peut fournir autant d eau que la pompe peut vidanger installer un tuyau d aspiration jusqu 30 pieds de long entre l injecteur et le clapet de pied Au moment o le niveau d eau dans le puits baisse lors d une forte demande la capacit de la pompe sera r duite et le niveau ne tombera pas sous le clapet de pied ce qui engendrerait la perte de Pamorcage de la pompe Si une pointe filtrante est utilis e installer un clapet de retenue pr s du tuyau d aspiration de la pompe au lieu de clapet de pied Fig 4b Toutes les
39. minutos y luego ap guela Saque el tap n de cargado Usted ha completado el primer ciclo de cargado que consiste en los pasos del 3 al 6 Este proceso se tendr que repetir de 2 a 6 veces dependiendo del largo de su l nea de succi n aproximadamente un ciclo de cargado por cada 5 pies de l nea de succi n Usted sabr cu ndo parar porque la bomba comenzar a bombear agua continuamente Una vez que la bomba comience a bombear agua continuamente ajuste firmemente el tap n de cargado con una herramienta Ajuste la v lvula de control en el mismo sentido que las manecillas del 2 g Control de Volumen de Aire Si se utiliza un tanque sin diafragma en el x z sistema de presion se debe usar un control de volumen de aire para reloj para que el flujo y la presi n sean estables v ase las instrucciones mantener un colch n de aire en el tanque de presi n Si no el aire en el de instalaci n con tuber a doble tanque ser gradualmente absorbido por el agua haciendo que el tanque 10 Si la bomba no saca agua en 8 intentos ap guela y revise que no haya se sature y la bomba haga un corto ciclo reduciendo significativamente la fugas de succi n vida del motor Un control de volumen de aire proporcionar la combinaci n Usando una v lvula de pie correcta de aire y agua y prevendr as la saturaci n por agua Vea las INSTALACI N DE UNA SOLA TUBER A instrucciones en el manual del tanque de presi n E A Ne gt
40. mpagne fermes et chalets qui ont une hauteur d aspiration jusqu 90 pieds Lorsque la pompe est utilis e pour un puits de surface l injecteur devra tre assembl directement sur le bo tier de la pompe Pour un puits profond l injecteur est install dans le puits et les deux combinaisons venturi buse peuvent tre utilis es Pour une hauteur d aspiration de 25 pieds 7 5 m tres ou moins l installer comme une unit pour puits de surface Fig 1a tandis que pour une hauteur d aspiration au del de 25 pieds 7 5 m tres l installer comme une unit pour puits de profondeur moyenne ou pour puit profond Fig 1b Pour ce qui est des installations d cal es il faut tenir compte des pertes de charge dans la conduite d aspiration voir le tableau 3 Diagramme de perte de charge Cette pompe n a pas t test e pour tre utilis e autour d une piscine injecteur Fig 1a Installation pour un puits peu profond 25 pieds 7 5 m tres max s de ig WJC Pompe A Injecteur Convertible A Amorcage Automatique Hauteur r duite en haute altitude INSTALLATION a Emplacement de la pompe Il est conseill d installer la pompe dans un endroit propre sec et a r offrant de l espace pour l entretien et une protection contre le gel La pompe devra tre boulonn e une assise solide de pr f rence en b ton et s assurer que l emplacement est bien drain Pour r duire les pertes de charge dans la condu
41. n del G 305446936 interruptor 9 Difusor 10 Impulsor H 305446941 305446942 11 Sello mecanico l 106196221 12 Funda E 305446950 H 305446941 305446942 13 Empaquetadura J 305446945 K 305446943 14 Placa de sello H 305446941 305446942 15 Lubricador L 305446952 16 Kit de sujetadores 17 Interruptor de presi n M 305446944 18 Motor N 305446955 305446956 305446957 19 Ensamble de la base P 305446960 Los elementos con identificadores iguales se venden empacan juntos El kit de sujetadores 16L es un juego completo de las piezas utilizadas para ensamblar la bomba Con fines pr cticos los kits de reparaci n A B E H y K contienen los sujetadores necesarios para volver a armar sus componentes GARANTIA LIMITADA LA PRESENTE GARANTIA ESTABLECE LA OBLIGACION EXCLUSIVA DE LA EMPRESA Y LA SOLUCION EXCLUSIVA DEL COMPRADOR ANTE UN PRODUCTO DEFECTUOSO Franklin Electric Company Inc y sus filiales de aqui en adelante la Empresa garantizan los productos que acompa an esta garantia contra defectos de material o mano de obra de la Empresa La Empresa tiene el derecho de inspeccionar cualquier producto devuelto en garantia para confirmar que dicho producto tiene un defecto de material o mano de obra La Empresa tiene el derecho exclusivo de elegir si desea reparar o reemplazar los equipos las piezas o los componentes defectuosos El comprador debe devolver el producto al lugar de compra para que se considere s
42. o 4 El producto se da como consecuencia de descuido abuso accidente uso indebido manipulaci n alteraci n instalaci n impropia operaci n mantenimiento o almacenamiento o por superar los valores m ximos recomendados establecidos en las instrucciones del producto TANTO EL VENDEDOR COMO LA EMPRESA NO SE RESPONSABILIZAR N POR NINGUNA LESI N P RDIDA O DA O DIRECTO ACCIDENTAL O CONSECUENTE INCLUIDOS ENTRE OTROS DA OS ACCIDENTALES O CONSECUENTES POR GANANCIAS PERDIDAS VENTAS PERDIDAS LESIONES PERSONALES O DA OS MATERIALES O CUALQUIER OTRA P RDIDA ACCIDENTAL O CONSECUENTE QUE SURJA DEL USO O LA INCAPACIDAD DE USO DEL PRODUCTO Y EL COMPRADOR ACEPTA QUE NO HABR OTRA SOLUCI N PARA ELLO LA GARANT A Y SOLUCI N DESCRITAS EN ESTA GARANT A LIMITADA CONSTITUYEN UNA GARANT A Y SOLUCI N EXCLUSIVAS Y SUSTITUYEN CUALQUIER OTRA GARANT A O SOLUCI N EXPL CITA O IMPL CITA QUE OTRAS GARANT AS Y SOLUCIONES QUEDAN EXPL CITAMENTE EXCLUIDAS INCLUIDAS A MODO DE EJEMPLO CUALQUIER GARANT A IMPL CITA DE MERCANTIBILIDAD O ADECUACI N PARA UNA FINALIDAD ESPEC FICA AL PUNTO EN QUE CUALQUIERA SE APLICA A UN PRODUCTO TENDR UNA DURACI N LIMITADA A LOS PERIODOS DE LAS GARANT AS EXPL CITAS QUE SE MENCIONARON ANTERIORMENTE DESCARGO DE RESPONSABILIDAD Todas las afirmaciones verbales acerca del producto realizadas por el vendedor la Empresa los representantes o cualquier otra parte no constituyen garant as no deben ser ten
43. o Pozo V lvula de pie Fig 4c POZO POCO PROFUNDO TANQUE EN LA L NEA S ES Se O control N Ce Drenaje oy Tap n de drenaje o So Tuber a d a V lvula de uberia de succi n Tap n de drenaje chequeo en Tuberia del respiradero linea Tuber a de succi n Sello del pozo Tuber a del respiradero Pozo V lvula de pie Sello del pozo Pozo Fig 4b POZO POCO PROFUNDO 7 Fig 4a POZO POCO PROFUNDO CON V LVULA DE PIE CON VALVULA DE CHEQUEO EN LINEA Interruptor SS de presi n V lvula de desfogue SS amp Codo de 90 Drenaje Tuberia Codo de 90 Valvula de control Tapon de cargado Tapon de drenaje Manguera de presi n de retorno Tuber a de succi n Tuber a del respiradero Sello del pozo Pozo Inyector V lvula de pie Fig 4d POZO PROFUNDO SISTEMA MONTADO EN EL TANQUE INSTALACI N CON TUBER A DOBLE CON V LVULA DE PIE CON V LVULA DE PIE 16 PIEZAS DE REPUESTO g Identificador del C digos de pedido para piezas de repuesto por n mero de modelo Descripci n h grupo del kit 1 2 hp 1 Cuerpo del inyector A 305446946 305446947 2 Boquilla B 305446948 305446949 3 Tubo Venturi A 305446946 305446947 4 Empaquetadura inyector B 305446948 305446949 5 Kit de tapones C 305446953 6 Medidor de presi n D 305446935 7 Ensamble de la valvula F 305446951 8 Juego de conexi
44. o el inyector est montado en el pozo y puede usarse cualquier combinaci n de venturi o boquilla Para columnas de succi n vertical de 25 pies 7 5 m o menos inst lela como unidad para pozo poco profundo Fig 1a y para columnas de succi n vertical de m s de 25 pies 7 5 m inst lela como unidad para pozo profundidad mediana o como unidad para pozo profundo Fig 1b En instalaciones donde hay una distancia entre el pozo y la bomba se debe tomar en cuenta las p rdidas por fricci n en la l nea de succi n referirse a la Tabla 3 Tabla de P rdidas por Fricci n Esta bomba no ha sido probada para usarse en reas de piscina Inyector Fig 1a Instalaci n Para Pozo Poco Profundo Respirad M x 25 pies 7 5m Respiradero V lvula de Pie WJC Bombas a Chorro Convertibles y Autocargables Menos a gran altitud INSTALACI N a Ubicaci n de la Bomba La bomba debe instalarse en un lugar limpio seco y ventilado con suficiente espacio para darle servicio y protegida de las temperaturas congelantes La bomba debe empernarse a una buena base preferiblemente de concreto y con drenajes adecuados Para reducir la fricci n en la tuber a de succi n y para que la bomba genere su m xima capacidad inst lela tan cerca del suministro de agua como sea posible Tuber as de Presi n y Succi n Se recomienda usar nicamente tuber as nuevas y limpias de 1 1 4 Si la bomba se instala a una distanci
45. ow and pressure is stable DRAINING Should the unit be subject to freezing it will be necessary to drain the pump ee 3 and tank To do this shut off the power to the pump at the main electrical panel 5 Start pump If a tap is visible you may see a short discharge of water which Open a tap in the water system to release the pressure Remove the drain and will last 5 10 seconds priming plugs from the pump 6 Run the pump for two minutes and then shut it off Remove priming plug 2 Fully open control valve counter clockwise rotation 3 Pour clean water through priming plug opening at top of casing until water starts flowing out 4 Install enclosed priming plug hand tighten TABLE 2 MAXIMUM WIRE LENGTH FT Fig 2 Electrical Connections WIRE GAUGE AWG vos loas son 115 14 14 12 10 8 1 2 i 230 14 14 14 14 14 z PA 115 14 14 10 8 8 3 4 230 14 14 14 14 12 Pressure Switch 4 115 14 12 10 8 6 230 14 14 14 14 12 Motor Load Based on an approximate 3 voltage drop MAINTENANCE WARNING RISK OF ELECTRICAL SHOCK Before servicing motor operated equipment shut off the power at the main electrical panel and disconnect the power supply from motor and accessories Use safe working practices during servicing of equipment a Lubrication The pump requires none Refer to motor manufacturer s instructions b Replacing Mechanical Seal See
46. s pouces seulement dans la plaque d tanch it Ne pas oublier que la surface lisse du si ge de c ramique doit tre tourn e vers l ext rieur REMARQUE Si l on pr voit que la pompe ne sera pas utilis e pendant plus d une semaine les l ments d tanch it doivent tre pos s sec sans lubrification 3 Remonter la plaque d tanch it sur le moteur 4 Lubrifier la partie rotative du joint d tanch it 7 avec de l eau savonneuse et la glisser sur l arbre avec l anneau en carbone faisant face au si ge de c ramique 5 Remettre en place la roue 6 et le diffuseur 4 6 Remettre le bo tier 2 en s assurant que le joint d tanch it n est pas Fig 3 endommag et qu il est bien en place 7 Raccorder les tubes au bo tier et au manostat 8 Rebrancher l alimentation lectrique 9 Amorcer la pompe la mettre en marche et s assurer qu il n y a pas du fuites GUIDE DE D PANNAGE a Le moteur ne d marre pas 1 Le manostat ne fonctionne pas en raison de fusibles br l s d interrupteurs ouverts ou d un raccordement desserr 2 Le manostat de la pompe n est pas ferm b Aucun pompage 1 La pompe n est pas compl tement amorc e 2 La hauteur d aspiration est trop lev e 3 Le clapet de pied n est pas immerg est enfoui dans la boue ou est obstru 4 La soupape de contr le est enti rement ferm e c Perte d amorcage 1 Fuites d air dans la conduite d aspiration
47. talled and its operation should be checked since a leak will prevent proper operation of the system Make sure the foot valve is located so that it will be submerged at all times If the well cannot supply as much water as the pump can draw install a tailpipe up to 30 ft long between the injector and the foot valve As the well draws down under heavy demand the pump s capacity will be reduced and the level will not go below the foot valve which would cause the pump to lose its prime If a sandpoint or driven well is used install a check valve next to the pump suction instead of the foot valve Fig 4b All installations must have a foot valve or a check valve in the suction pipe c Pump to Tank Fittings The discharge pipe from the pump to the tank should be as short and direct as possible and should be the same size as that of the pump discharge tapping A check valve should never be installed between the pump and the tank d Service Line The service line should be connected as shown in Fig 4a b c or d The size of the service line required is governed entirely by the amount of water needed and the length of the pipe The pipe selected should be large enough so that the friction loss determined from Table 3 Friction Loss Chart will never exceed 20 ft 6m head Adhere to the guidelines of national state and local plumbing codes when installing this product Check with the appropriate agencies or water system professional for addit
48. tecci n de falla de conexi n a tierra GFI para todos los aparatos el ctricos que operen cerca del agua Instale un interruptor adecuado activado por fusible en la l nea y aseg rese que el cableado sea del tama o adecuado y est propiamente aislado Un cable de un menor tama o entre el motor y la fuente de energ a limitar adversamente la capacidad de arranque y de carga del motor Se recomienda los di metros m nimos para los cables de extensi n del motor Ver Tabla 2 Para seguridad adicional la bomba y el motor deben estar conectados a tierra en el casco del pozo si es de metal o a tierra en el panel de distribuci n Medidor de Presi n Si la bomba viene con un indicador de presi n o si usted desea instalar uno ste se debe instalar en el agujero de 1 4 pulg NPT en la parte frontal del cuerpo de la bomba junto a la abertura de descarga Usando una v lvula de chequeo en la l nea 1 Abra la v lvula de descarga en la l nea de servicio y un grifo cercano para controlar el flujo de agua Abra completamente la v lvula de control con rotaci n en contra de las manecillas del reloj Vierta agua limpia dentro de la bomba por el agujero en la parte superior del cuerpo de la misma hasta que el agua comience a rebalsarse Coloque el tap n adjunto de cargado Encienda la bomba Si hay un grifo visible usted ver una descarga corta de agua lo cual puede durar de 5 a 10 segundos Haga funcionar la bomba por 2
49. tionnement de la pompe en cycles courts Ce genre de situation abr ge consid rablement la dur e de vie du moteur En installant un r gulateur de volume d air on obtient le bon rapport air eau et on pr vient la saturation du syst me Pour plus de renseignements on devrait consulter le manuel qui accompagne le r servoir pression Soupape de suret Il est recommand d installer une soupape de s curit haute pression un certain point dans le syst me d eau Placez la proximit de la d charge de la pompe dans un endroit pouvant offrir un drainage ad quat Assurez vous de la diriger de telle mani re qu aucun coulement d eau ne puisse clabousser un dispositif lectrique FONCTIONNEMENT A AVERTISSEMENT DE NE PAS FAIRE FONCTIONNER LA POMPE A SEC Fig 2 Branchements lectriques Circuit d alimentation lectrique Mise la Manostat terre Moteur charge 8 AVANT L AMORCAGE SINON LE JOINT D ETANCHEITE ET LA ROUE DE TURBIN E SERAIENT ENDOMMAG S DE FA ON PERMANENTE AMOR AGE Remarque La quantit d eau doit tre suffisante pour remplir la conduite d aspiration et le bo tier de la pompe Le temps d amorcage est fonction de la distance allant de la source d eau la pompe 5 15 min Utilisation d un clapet anti retour sur conduite 1 Ouvrir le clapet de refoulement se trouvant sur la conduite de raccordement et pr s du robinet pour surveiller le d bit d eau 2
50. u garant a Con sujeci n a los t rminos y condiciones enumerados a continuaci n la Empresa reparar o reemplazar al comprador cualquier parte de este producto que resulte defectuosa como consecuencia del material o la mano de obra de la Empresa La Empresa considerar los productos para su garant a durante 12 meses a partir de la fecha de instalaci n o durante 24 meses a partir de la fecha de fabricaci n lo que suceda primero EN NING N CASO la Empresa se responsabilizar por el costo de mano de obra ni por otros costos en los que haya incurrido un cliente al sacar y o colocar un producto pieza o componente La Empresa se reserva el derecho de cambiar o mejorar sus productos o cualquiera de sus partes sin verse obligada a ofrecer dicho cambio o mejora a productos vendidos anteriormente ESTA GARANT A NO SE APLICA A los productos da ados por casos de fuerza mayor como rayos desgaste y rotura normales servicios de mantenimiento normales y las piezas utilizadas en conexi n con dichos servicios ni otras condiciones que excedan el control de la Empresa Cualquiera de las condiciones expuestas a continuaci n INVALIDAR INMEDIATAMENTE ESTA GARANT A 1 El producto se utiliza para fines que no son para los que fue dise ado y fabricado 2 El producto no se instal de conformidad con los c digos ordenanzas y pr cticas comerciales aceptadas aplicables 3 El producto no fue instalado por un contratista certificado por Franklin
51. y charged 4 Foot valve leaks or is stuck open TABLE 3 FRICTION LOSS CHART FOR PLASTIC PIPE For galvanized pipe double the figures Loss of head in ft due to friction per 100 ft of pipe Nominal Pipe Size U S GPM 4 3 74 1 15 0 30 0 14 5 5 66 1 75 0 46 0 22 6 7 95 2 45 0 65 0 31 7 10 60 3 25 0 86 0 41 8 13 50 4 16 1 10 0 52 9 16 80 5 17 1 35 0 65 10 20 40 6 31 1 67 0 79 0 23 11 24 40 7 58 1 98 0 95 0 27 12 28 60 8 85 2 33 1 10 0 32 14 38 00 11 80 3 10 1 46 0 43 16 48 60 15 10 3 96 1 87 0 55 18 60 50 18 70 4 93 2 33 0 69 20 73 50 22 80 6 00 2 83 0 84 Loss of head in meters due to friction per 100m of pipe Nominal Pipe Size l min 15 3 70 1 15 0 30 0 13 20 5 33 1 64 0 43 0 19 25 7 14 2 18 0 56 0 27 30 13 50 4 13 1 08 0 49 35 16 30 5 00 1 31 0 61 40 23 50 7 30 1 90 0 88 0 25 45 28 30 8 74 2 31 1 07 0 29 50 34 20 10 60 2 79 1 32 0 38 55 40 70 12 60 3 32 1 56 0 46 60 48 10 14 90 3 92 1 85 0 54 65 55 70 17 30 4 54 2 15 0 63 70 63 80 19 70 5 20 2 46 0 73 75 72 20 22 40 5 89 2 78 0 83 TYPICAL INSTALLATIONS Priming 90 Pressure Plug Switch O i Service Drain Line Suction Pipe Vent Pipe Well Seal Well Foot Valve Priming Relief Valve Pressure switch Flu C A a Service Drain Line 3 InlineCheck Drain Plug Valve Suction Pipe Vent Pipe Well Seal Well Fig 4b SHALLOW