Home

ShowLED Classic manual

image

Contents

1. CcClossic Controller dear le version 3 l CONTENTS Introduction Safety instructions How to replace the fuses Controller description Wiring the starcloth to the controller Connecting the ShowLED controller Setting up the control network Stand Alone Mode DMX Mode Mixing controllers with different firmware Stand Alone Mode DMX Mode The operator console and the menu structure Flowchart of the menu structure Description of the parameters Graphical presentation of the DMX channel arrangement Tips and tricks FAQ s XLR output detail Troubleshooting Contact Information amp Support channels Technical data Declaration of conformity 20 20 20 21 21 22 23 INTRODUCTION Congratulations on your recent purchase of a ShowLED Controller with the following features 8 output channels for driving LEDS DMX compatible The DMX signal is cleaned up and amplified every time it passes through a controller Two or more controllers can be synchronised Chase patterns Stand alone or selected by the DMX signal Selection of hard or soft chase Variable chase speed Anumber of predefined patterns Interactive operator console The parameters of the controller are accessible though the LCD and menu buttons e g The DMX base address The LED outputs are protected against short circuit The supply voltage can vary between 90 and 250 Vac Uses standard cables Energy efficient Full range DMX addressing Improved dimmer c
2. DMX Mode Configuration 1 Using the built in patterns With use of a lightboard Controller 1 Controller 2 Last Controller DMX DMX DMX DMX DMX DMX in out in out in out In this configuration controller 1 is set in mode 10 all the others are set in mode 1 This configuration requires minimum 5 DMX channels Note if you want to add another device moving heads dimmers to this control network it can only be put before the first controller Configuration 2 Dimming function of each output Controller 1 Controller 2 Last Controller DMX DMX DMX DMX DMX DMX in out in out in out In this configuration all the controllers are set in mode 8 This configuration requires minimum 8 DMX channels You can choose if you want to address the controllers all together or separately By setting all the controllers in this control network on the same DMX base you can address all the controllers together By setting all the controllers in the control network on a different DMX base e g 1 9 17 25 you can address all the controllers separately Note if you want to address all the controllers separately you will need 8 DMX channels per controller e g 4 controllers require 32 channels MIXING CONTROLLERS WITH DIFFERENT FIRMWARE Stand Alone Mode Master slave operation No lightboard present Controller 1 Controller 2 Controller 3 Controller 4 Controller 5 V1 0 gt V1 0 gt V 0 30 V 0 30 V 0 30 DMX DMX DMX DMX DMX DMX D
3. 10 and 11 You can address remotely the operational parameters by the DMX signal It will save you time you don t have to program your own sequences DMX base Use this parameter to set the DMX base address of the ShowLED controller The DMX base address can be set between 1 and 504 The following built in patterns are only available if operating mode O 2 9 10 or 11 is selected If operating mode 0 or 2 is selected they are available on the operator console If operating mode 9 10 or 11 is selected they are available through the DMX signal Pattern Type Channel offset 0 gc rion ss 0 7 All Channels OFF x 8 31 Chase Pattern 1 Random min 3 channel on 32 55 Chase Pattern 2 Special 56 79 Chase Pattern 3 Sequence with 4 channels on 80 103 Chase Pattern 4 Sequence with 5 channels on 104 127 Chase Pattern 5 Sequence with 6 channels on 128 151 Chase Pattern 6 Running light 7 channels on 152 175 Chase Pattern 7 Running light 6 channels on 176 199 Chase Pattern 8 Running light 5 channels on 200 223 Chase Pattern 9 Running light 4 channels on 224 247 Chase Pattern 10 STROBE 248 255 All Channels ON Forced operation all other parameters have no influence 1The DMX base address is also known as the DMX start address 17 Pattern Behaviour Channel offset 1 gc ere 0 63 Soft chase 64 127 Hard chase 128 191 Soft chase inverted
4. s 1 How can I read the firmware version Press the PRG button once Press 4 times the Down button Now your re able to read the firmware version 2 Where can I find which hardware version my controller has got At the back of the device you ll find a barcode serial number The code is built as follows for example 025608D02000092 These three digits represent the hardware version 020 reads as version 2 0 3 What is the maximum length of the cable between the controller and the cloth You can determine the maximum length of the cable by using the following table Number of LEDs in the cloth s ps iss fa 13m soo 15m XLR port 1 and 2 orange XLR port 3 and 4 green Pin 1 channel 1 Pin 1 channel 5 Pin 2 channel 2 Pin 2 channel 6 Pin 3 channel 3 Pin 3 channel 7 Pin 4 channel 4 Pin 4 channel 8 Pin 5 common anode Pin 5 common anode XLR OUTPUT DETAILS TROUBLESHOOTING The controller won t turn on Make sure you have tension on the power outlet A multimeter can be helpful in checking this If you are sure that you have tension from the power outlet connect the powercord to the device If the LEDs are not lit and there is no text on the display and the display backlight is not lit the fuse s are probably blown If you need to replace the fuses make sure to follow the procedure explained in the section Safety instructions The LEDs don t light up If the display works but
5. input IEC power inlet Note The pictures are not to scale WIRING THE STARCLOTH TO THE CONTROLLER Connecting one cloth to the controller a betr 1to4 Starcloth channels 5 to 8 Fa XLR plug 5 pole male Connecting two small cloths to the controller channels 1 to 4 channels 5 to 8 Aoo small starcloths 4 Note The connectors with the same colour code are switched in parallel internally CONNECTING THE SHOWLED CONTROLLER 1 Connect your application to the LED output connectors of the controller 2 Connect the powercord to the MAINS 90 250V input of the controller 3 At this point you will need to set the parameters of the controller You will learn how to do so from this manual 4 If you have more than one controller to connect See setting up the control network further in this manual SETTING UP THE CONTROL NETWORK The control network is set up with the use of 5 pole XLR cables In the following drawings only the control network is drawn Depending on your application you will choose a configuration Stand Alone Mode No lightboard present Last Controller Controller Controller 1 2 DMX DMX in out DMX DMX DMX DMX in out in out The first controller is set to operating mode 0 All other controllers are set to operating mode 1 All parameters can be altered on the first controller 1 For instance a starcloth a logo 10 SETTING UP THE CONTROL NETWORK
6. the LEDs dont light up set the controller in default mode Push the PRG button the DOWN button and again the PRG button If the LEDs are still not lit the problem probably lies in the wiring For all further questions or remarks please visit the support section of our website at www showled com In order to serve you in a better way we invite you to send suggestions and feedback to info showled com CONTACT INFORMATION amp SUPPORT CHANNELS e Visit the support section of our website at www showled com Here you will find up to date FAQ s and Tips and Tricks Send your questions to info showled com we will reply to you as soon as possible e Place a call to ShowLED FZC Tel 971 6 557 83 07 Office hours Sunday through Thursday from 09 00 to 18 00 Fridays and Saturdays we are closed e Note that we are in the GMT zone 4 hour Here are some useful links to convert time zones www worldtimeserver com www timezoneconverter com www timeanddate com Contact address ShowLED FZC P O Box 120888 Warehouse Q4 006 Sharjah Airport Free Zone Sharjah United Arab Emirates 22 TECHNICAL DATA Specs are listed for both controllers the LCO25608DR difference is between brackets Electrical Input Input voltage range 90 250 Line frequency 47 63 Input current at 100 230 V AC 0 8 0 45 0 6 0 4 Inrush current 15 Input power 50 33 Fuses 2 xT2 0A slow blow Output O
7. with the environmental limits Do not exceed them See technical data Keep a minimum distance of 1 meter between you or the audience and the LEDs Do not stare into the LEDs especially when narrow angle LEDs are used This device is designed and tested for driving LEDs do not use it for other purposes Do not expose the controller to water rain or direct sunlight Do not subject to excessive shock by dropping the unit How to replace the fuses Disconnect the powercord Unscrew the 4 bolts on the two sides of the device and the 4 top screws of the XLR connectors of the LED outputs You need a PH1 screwdriver Remove the top of the device it is not necessary to disconnect the flat cable you encounter Locate the fuse holders marked on the PCB as F1 and F2 You can open the fuse holders by turning the caps counter clockwise Determine which fuse is blown If you are not sure replace both Replace the fuse s with the right kind fuse 2 0A slow blow 5x20 mm Replace the caps together with the fuses and lock them by turning clockwise Put the top of the device back into position and fasten the 4 little bolts on the two sides of the device and the 4 top screws of the XLR connectors of the LED outputs Reconnect the powercord and check if the device is working properly 2 pairs of 5 pole XLR plugs each pair controls 4 channels LED OUTPUTS Operator Console A DMX input 5 pole XLR B DMX output 5 pole XLR C MAINS
8. 2 Electromagnetic compatibility for audio video audio visual and entertainment lighting control apparatus for professional use Part 2 Immunity EN 55022 Standards of radio disturbance of information technology equipment EN 55024 Standards of immunity characteristics of information technology equipment Sharjah United Arab Emirates Kenny Janssens Managing Director 01 9 2011 Date of issue Signature of authorised person 23 SHOWLE LED starcloths for theatres TV studios concerts night clubs exhibitions corporate events movie theatres cruise ships Visit our website for further information or to check contact details of your local ShowLED supplier www showled com
9. MX DMX DMX DMX in out in out in out in out in out The first controller eee is set to operating mode 2 operating mode 3 All other controllers are set to operating mode 1 Legend V 1 0 gt firmware version 1 0 or higher V 0 30 firmware version 0 30 11 12 MIXING CONTROLLERS WITH DIFFERENT FIRMWARE DMX Mode Configuration 1 Using the build in patterns See also configuration 2 Controller 1 Controller 2 Controller 3 Controller 4 V1 0 gt V1 0 gt V 0 30 V 0 30 DMX DMX DMX DMX DMX DMX DMX DMX in out in out in out in out operating operating operating operating mode 11 mode 12 mode 8 mode 8 Configuration 2 Dimming function of each output See also configuration 3 Controller 1 Controller 2 Controller 3 Controller 4 V1 0 gt V1 0 gt V 0 30 V 0 30 DMX DMX DMX DMX DMX DMX DMX DMX in out in out in out in out operating operating operating operating mode 12 mode 12 mode 8 mode 8 Legend V 1 0 gt firmware version 1 0 or higher V 0 30 firmware version 0 30 THE OPERATOR CONSOLE AND THE MENU STRUCTURE The operator console consists of an LCD and three buttons This console is the physical interface that lets you access a menu structure The menu structure lets you modify the parameters of the device The first button PRG has a double function depending on where you are in the menu structure the function can be an Escape or a Confirmation The UP button lets you navigate through the structure or incre
10. ment a parameter The DOWN button lets you navigate through the structure or decrement a parameter A flowchart of the menu structure is given on the next page The structure has three types of submenus namely actions set up parameters and operational parameters Actions Exit no changes Escape function the previously saved parameters are restored Return default The parameters are restored to the factory defaults Broadcast parameters Passes the parameters to the other controllers in the DMX chain Exit and save After altering the parameters and the parameters are satisfying you must save them Firmware Va AN Displays the current firmware of the device It s an aid to help us to give you additional support Set up parameters Operating mode DMX base Operational parameters Pattern type Pattern behaviour Chase speed Minimum intensity Maximum intensity You need to alter only the set up parameters when the set up of your application changes You will find an explanation of the parameters in section description of the parameters 13 FLOWCHART OF THE MENU STRUCTURE Idle message in this state the LCD backlight is dimmed www showled com EXIT NO CHANGES Escape no changes are made Returns the device to the default settings Send the parameters to other devices in the chain Exits and saves your changes Escape no changes are made See next page Only available when operating
11. mode 0 or 2 is selected Modify values with the UP and DN buttons OPERATING MODE DESCRIPTION OF THE PARAMETERS Operating mode This is the first parameter you need to set before entering the other ones Depending on the configuration of your application you must choose a certain operating mode See also section Setting up the control network for more clarity DMX channel Description Access to the operational parameters Stand alone operation Master On the controller menus Improved Stand alone operation Slave Improved listens to other controller in mode 0 Stand alone operation Master On the controller menus Standard Stand alone operation Slave bk Standard listens to other controller in mode 0 reserved reserved reserved reserved Dimming function of each Improved output Pattern type Pattern behaviour By the DMX signal Improved Chase speed Min Intensity Max Intensity Pattern type Pattern behaviour By the DMX signal Improved Chase speed Min Intensity Max Intensity solves synchronisation problems Pattern type Pattern behaviour By the DMX signal Standard Chase speed Min Intensity Max Intensity solves synchronisation problems Dimming function of each Standard output reserved reserved reserved Doesn t apply Notes Mode 0 The controller will act as a lightboard for the other controllers Mode 9
12. pattern 192 255 Hard chase inverted pattern Chase Speed Channel offset 2 gc ere Minimum speed Maximum speed Minimum Intensity Channel offset 3 Limiter function sets the minimum intensity level When set to a value higher than zero the LEDs will not dim completely Maximum Intensity Channel offset 4 Limiter function sets the maximum intensity level When set to a value lower than 255 the LEDs will not light up at full capacity Note the maximum intensity has a higher priority than the minimum intensity 255 GRAPHICAL PRESENTATION OF THE DMX CHANNEL ARRANGEMENT This is only valid if operating mode 9 10 or 11 is selected This presentation can be of help when you are using a low cost DMX lightboard Channel Channel Channel Channel Channel offset 0 offset 1 offset 2 offset 3 offset 4 255 Ke OI OU Qa v OU a a U Maximum Intensity This is only valid if pattern 2 is selected Channel Channel Channel Channel Channel offset 0 offset 1 offset 2 offset 3 offset 4 Chase speed Not applicable Maximum Intensity 20 TIPS AND TRICKS If you have altered one or more parameters make sure to leave the menu with the action exit and save Otherwise your settings will be lost when the controller is turned off A quick way to make the LEDs light up is to set the controller in default mode Push the PRG button the DOWN button and again the PRG button FAQ
13. urve Notes This manual applies to firmware version 1 0 or higher and hardware versions 2 0 and above Please consult our website for possible errata and modifications ShowLED is our brand name for LED products we develop for the entertainment industry SAFETY INSTRUCTIONS WARNING To avoid electric shock the power cord protective grounding must be connected to ground Make sure you understand the function of each connection before you connect it See that all connections are made correctly before turning on the controller Always disconnect the device from the mains supply when connecting the signal leads the power cord should be connected last Do not apply voltage higher than 250 Vac to the device See also technical data In case of an emergency you can disconnect power from the device by pulling out the power cord Keep the power cord easily accessible at all times If your application set up does not allow easy access to the power cord install a mechanical circuit breaker in the supply line going to the device The device has 2 fuses placed inside replace them only with the correct type See next page how to replace them If the controller hangs on a starcloth and is not supported by a floor or a table you must secure it with a mechanical safety The connecting cables are NOT mechanical safeties If you are not familiar with mechanical safeties feel free to contact us we can provide you with advice Take care
14. utput voltage 5 Output current 8 5 Output power A0 25 Fuses Polymeric PPTC Environmental Operating Ambient temperature 5 45 K Relative humidity lt 80 Storage Ambient temperature 5 35 SS Relative humidity lt 60 Mechanical Dimensions 190 x 112 x 43 mm Weight 1186 g 1 at nominal load 2 start up current only lasts for 2 milliseconds 3 placed inside the device 4 when the outputs are set to maximum and have a nominal load 5 the sum of the 8 outputs D every led output is short circuit protected by an automatically reset table fuse 7 no condensing 8 the stricter storage parameters ensure a long life of the LCD DECLARATION OF CONFORMITY 3rd edition We ShowLED FZC P O Box 120888 Warehouse Q4 006 Sharjah Airport Free Zone Sharjah UAE Declare that the product ShowLED Classic System containing a subset of the following components Controller type LCO25608DR Controller type LC051208DR Led string type BW 12LED Led string type BW 16LED is in conformity with the essential requirements of the following directives and standards Low Voltage Directive 73 23 EEC EN 60950 2nd Ed Standard for safety of information technology equipment Including amendments A1 A2 A3 A4 and A11 EMC Directive 89 336 EEC and 92 31 EEC EN 55103 1 Electromagnetic compatibility for audio video audio visual and entertainment lighting control apparatus for professional use Part 1 Emission EN 55103

Download Pdf Manuals

image

Related Search

Related Contents

Owner`s Manual Manuel De L`utilisateur Vacuum  English - strong>strong>strong>strong>  Toshiba TLP381 Projector User Manual  NASLite+ User Manual r1.1 07-2005  Kingston Tools Ultimate Memory Guide  Cat 2009 V-1.indd - Hood Finishing Products  取扱説明書はこちら  Toshiba E200 Laptop User Manual  UMP2 User`s Manual  AMRESCO Protein EZ-Vision, 4 取扱説明書  