Home
DOMUSFIRE C29-C35-C39
Contents
1. DOMUSFIRE C29 C35 C39 46 COLA 2 8 Wiring diagram for zone system Before installing the boiler in the home check the type of heating system if there are several zones a special electronic controller for multi zone circuits available as an optional must be installed This is to prevent overheating of the unit due to possible simultaneous closing of the zone valves and consequent stopping of hot water delivery flow 2 9 Plumbing connections The heating capacity of the unit must be previously established by calculating the building s heat requirement according to current regulations by contacting a specialised technician According to Italian Standard UNI 10412 2 2009 and proper installation technique a heating system must be provided with all the adjustment control and safety components to ensure proper and safe operation as well as shutoff and non return valves to allow the boiler to be isolated from the system in case of maintenance and or checks There are two types of systems CLOSED VESSEL system and OPEN VESSEL system In the present case both types are compatible with our unit provided all the adjustment control and safety components required by the current regulations on installation are installed The pellet boiler has an internal heating water circuit complete with circulating pump safety valve air vent temperature probes and pressure transducer If the heating system is managed in zones a multi zone
2. 5 e Co T 0 D a a 3 3 a ala o 9 9 SE 2 2 hi T 2 2 13 E 13 8 Bly g S o o 5 8 8 d 8 a E E 5 D gt gt 3 N sek A A amp n N WI ES 3 o a o 3 w 521 7 624 7 Water resistance T 10K Water resistance T 20K o a P 5 a 2 E 3 134 3 62 6 148 6 62 6 159 5 62 6 14 1 5 4 16 3 5 4 18 2 5 4 10 14 0 10 0 14 o gt a a n Tiraggio canna fumaria min max 0 m 100 230V 50Hz 6A Accensione Start 476 Stand by 4 P nom 160 P rid 153 1300x700x698 NEN 1300x700x698 1300x700x698 alla Potenza nominale e Potenza ridotta Nominal output and Reduced output consumo di pellet pu variare dal tipo di pellet utilizzato Pellet consumption can vary according to the type of pellets used a Pim Syn ojo lo o sis gt 8218 sts S 2 a olio j s 3 8 ale 3 2 JS fo sl els 215 SIS 5 lg 8 8 8 012 ofS o 3 Lo bg E EN ES a 5 9 o La 3 Q 3 a o 2 3 g 3 si HxExP 3 9 5 3 a 3 v o go lt 9 8 DOMUSFIRE C29 C35 C39 COLA Ingombri Caldaia a pellet mod DOMUSFIRE C29 DOMUSFIRE C35 DOMUSFIRE C35 DETTAGLI gt LEGENDA Allacciamento cavo elettrico Scarico acqua sovrappressione 1 2
3. Incrementa la potenza o il valore della Temperatura termostato acqua del boiler sanitario se abilitato Temperatura Livello potenza SET sanitario Contatto esterno Crono La Figura a fianco descrive il significato dei segnalatori di stato Resistenza elettrica sulla parte sinistra del display L attivazione nel display di uno dei segmenti segnala l attivazione Coclea del dispositivo corrispondente secondo l elenco a fianco Estrattore fumi Attivazione Circuito SANITARIO Attivazione Circuito RISCALDAMENTO ALLARME 4 3 Accensione 4 3 1 Controllo prima dell accensione Prima di procedere con l accensione della caldaia necessario verificare i seguenti punti assicurarsi di aver letto e compreso quanto riportato nel manuale i serbatoio deve essere carico di pellet la camera di combustione deve essere pulita il braciere deve essere completamente libero pulito da eventuali residui di combustione e posizionato correttamente nella sede del portabraciere verificare la chiusura ermetica della porta fuoco e del cassetto cenere verificare il collegamento del cavo elettrico e la commutazione in ON 1 dell interruttore collocato posteriormente alla caldaia verificare l apertura delle valvole di intercettazione mandata e ritorno nonch la pressione del circuito idraulico 21 DOMUSFIRE C29 C35 C39 COLA bruciare istruzioni etichetta Eventuali accensioni eseguite a seguito di l
4. A Valider la programmation WEEK END uniquement apres avoir d sactiv la programmation hebdomadaire Pour viter les op rations d allumage et d extinction ind sir es valider un seul programme la fois D sactiver le programme journalier si l on souhaite utiliser le programme hebdomadaire il convient dans ce cas de d sactiver le programme week end 88 Ta I 0 Fernie M Niveau de 1436 Yi imi PSB SERRE Jour Fen tre de dialogue PRU Fen tre de dialogue 4315 Tid hn 4 03 EEH End DOMUSFIRE C29 C35 C39 COLA 4 6 2 menu 02 R glages de l utilisateur Ce menu permet d effectuer plusieurs r glages de la fa on suivante SET HORLOGE Avant de faire fonctionner la chaudi re r gler d abord l heure et la date courante pour permettre d effectuer la programmation du chrono La commande lectronique est dot e d une pile au lithium mod CR2032 de 3 Volt qui assure l horloge interne une autonomie sup rieure 4 5 ans si l horloge ne conserve pas l heure lorsque la chaudi re est teinte ou si elle affiche plusieurs z ros au rallumage s adresser au SAV qui se chargera de remplacer la pile Mode Veille La s lection du mode veille STAND BY provoque l extinction imm diate de la chaudi re lorsque la temp rature de l eau reste au dessus de la temp rature de consigne SET pour une dur e pr d finie Le rallumage successif en mode automatique ne sera
5. nie 8 amp e allea v 2 58 2 ale Bile 8 2126 58 z ses gt gt 23 T sil m a 28 OLVISOMNIA 140 DOMUSFIRE C29 C35 C39 COLA 2 8 Esquema el ctrico para instalaci n por zonas Antes de instalar la caldera en la vivienda controle el tipo de sistema de calefacci n Si est dividido en zonas es necesario montar una centralita electr nica espec fica para circuitos multizona que se suministra como opcional Esto es necesario para evitar que el equipo se sobrecaliente por el posible cierre simult neo de las v lvulas de zona con el consiguiente bloqueo de la salida de agua caliente 2 9 Conexiones hidr ulicas La potencia t rmica del equipo debe ser calculada por un t cnico especializado antes de realizar la instalaci n teniendo en cuenta las necesidades de calor del edificio conforme a las normas vigentes Seg n la norma italiana UNI 10412 2 2009 y la buena pr ctica de instalaci n los sistemas de calefacci n deben estar provistos de todos los dispositivos de regulaci n control y seguridad necesarios para garantizar un funcionamiento sin riesgos as como de v lvulas de corte y antirretorno para aislar la caldera de la instalaci n en caso de mantenimiento o control Hay dos tipos de instalaciones de VASO CERRADO y de VASO ABIERTO La caldera objeto de este manual es compatible con ambos tipos siempre que se instalen todos los dispo
6. 3 bar Ritorno impianto riscaldamento 1 M O Aspirazione aria comburente 60 mm Allacciamento acquedotto 1 2 F Scarico acqua impianto Scarico aria impianto Attacco mandata senza pompa 1 D Ispezione pompa mandata Mandata impanto riscaldamento 1 D Allacciamento tubo espulsione fumi 100 mm M Termomanometro N Pannello comandi mod EVO Porta apribile per accesso porta fuoco cassetio cenere Piedini regolabili Sportello serbatoio pellet Pomello scuoti turbolatori LEGENDA ELEMENTI OPZIONALI Ispezione pompa mandata sanitario OPT T Ritorno sanitario OPT 3 4 M pompa U Mandata sanitario 3 4 M pompa V Scarico acqua sovrappressione sanitario 1 2 F 6 bar W Ritorno sanitario OPT 1 2 M scambiatore Z Mandata sanitario OPT 1 2 M scambiatore ACCESSORI SU RICHIESTA GRUPPO SANITARIO CON POMPA e SCAMBIATORE INTERNO CALDAIA GRUPPO SANITARIO CON POMPA INTERNO CALDAIA SERBATOIO PELLET AGGIUNTIVO CAPACITA circa 250 kg 9 DOMUSFIRE C29 C35 C39 COLA Apertura chiusura porta fuoco Caldaia mod DOMUSFIRE Per aprire la porta esterna tirare verso l esterno Per aprire la porta inserire la maniglia in dotazione e ruotare in senso orario Maniglia apertura chiusura porta fuoco e porta cassetto cenere Apertura senso antiorario Chiusura senso orario 1 5 Combustibile
7. Pass un certain temps si la temp rature des fum es n a pas atteint la valeur mini admissible la chaudi re se mettra en position d alarme Il est interdit d utiliser des liquides inflammables pour l allumage En cas d allumages manqu s plusieurs fois de suite faire appel au SAV 84 DOMUSFIRE C29 C35 C39 COLA 4 10 Fonctionnement Apr s la phase de d marrage r ussie la chaudi re passe en mode FONCTIONNEMENT qui repr sente le mode normal L utilisateur peut r gler la puissance de chauffe par les boutons P6 et P5 de la valeur maxi 5 la valeur mini 1 La validation ON de la fonction circuit sanitaire s affiche avec le segment Led A 14 36 spc SBC ERALAI LI Il est recommand de contr ler le niveau des granul s dans le r servoir afin d viter que la flamme ne A s teigne pour cause de manque de granul s S assurer que l appareil est teint pour effectuer le chargement des granul s Le couvercle du r servoir granul s doit toujours rester ferm Ne l ouvrir que pour effectuer le chargement des granul s Les sacs de granul s doivent tre stock s une distance d au moins 1 5 m de la chaudi re Temp rature Eau T chambre 4 4 1 Modification du pr r glage de la temp rature de l eau Pour modifier la temp rature de l eau il suffit de s lectionner le MENU 03 en appuyant sur le bouton puis P1 sur les touches et P2 pour acc der au menu M 3 6 et r g
8. An der unteren Wand des Pelletbeh lters und zwar am Pelletf rderer sowie am oberen Teil der Heizkammer befinden sich zwei Temperaturf hler die an den jeweiligen Sicherheitsthermostaten angeschlossen sind die bei Uberhitzung die Pelletzuf hrung automatisch unterbrechen In diesem Fall laufen das Saugzuggeblase und oder die Ventilatoren weiter damit das Gerat schnell abk hlen kann Die Anomalie wird mit der Meldung AL 7 THERMOSICHERUNG am Bedienpanel angezeigt Bei Ansprechen des Thermostats folgendermaBen vorgehen Den Kessel mindestens 45 Minuten abk hlen lassen Den Thermostat durch Dr cken des Tasters neben dem Schalter an der Kesselr ckseite nebenstehende Abbildung zur cksetzen zuvor die Schutzeinrichtung entfernen und zwar T1 Thermostat Wassertemperatur Heizkammer T2 Thermostat Temperatur Pelletzuf hrungskanal Den Kessel dann ganz normal wieder einschalten Ansprechtemperatur des Thermostats am Pelletbeh lter gt 85 C 3 5 Flammenruckschlagschutz im Pelletzufuhrungskanal Das R ckschlagen der Flammen wird verhindert durch gt Unterdruck in der Brennkammer siehe Abschnitt 3 2 Siphonform des Pelletzuf hrungskanals Uberhitzungsschutz des Beh lters siehe Abschnitt 3 4 3 6 Uberstromsicherung Der Kessel ist durch 2A Sicherung en an der Zuleitung des hinten angebrachten Hauptschalters gegen Uberstrom gesch tzt 3 7 Uberdruckventil Wasserkreis Ein eventueller Uberdruck d
9. 62 6 159 5 62 6 Caudal de humos Flue gas flow Tiro m n max Draught min max 14 1 5 4 163 54 182 54 10 14 0 10 0 14 Tubo de salida de humos Fume outlet pipe Alimentaci n el ctrica Electrical power 100 230V 50Hz 6A Consumo el ctrico Rated input power Medidas HxLxP Dimensions HxLxP Accensione 476 Stand by 4 P nom 160 P rid 153 1300 x 700 x 698 1300 700 698 1300 x 700 x 698 Peso Weight 272 275 275 a Potencia nominal e reducida Nominal output and Reduced output El consumo de pellets pueden variar seg n el tipo de pellet utilizado Pellet consumption can vary according to the type of pellets used COLA s r l Viale del Lavoro 719 37040 Arcole VR Italy Tel Impr 02990180230 Capitale Sociale Euro 52 000 00 Lv A VR 301021 Socio Unico 045 7635780 045 6144043 Fax Amministrazione 045 6100317 Fax Commerciale 045 7639032 Fax Assistenza 045 7639030 Fax Logistica 045 6144048 MIS info anselmocola com on line www colastufe com direzione e coordinamento della Ferroli spa 161 DOMUSFIRE C29 C35 C39
10. 698 1300 x 700 x 698 1300 x 700 x 698 Dimensions HxLxP Behalterinhalt Ts gt Nennwert Reduzierter wert Der Verbrauch kann je nach Pelletart unterschiedlich sein 102 DOMUSFIRE C29 C35 C39 COLA Platzbedarf Pelletkessel Mod DOMUSFIRE C29 DOMUSFIRE C35 DOMUSFIRE C39 DETAIL A LEGENDE Anschluss Netzkabel Wasserabfluss bei berdruck 1 2 Innengewinde 3 bar Anlaaenr cklauf 1 AuBenaewinde D Verbrennungsluftansaugung 60mm Wassernetzanschluss 1 2 Innengewinde Wasserablass der Anlage G Wasserablass der Anlage amp Anschluss Vorlauf ohne Pumpe 1 Au engewinde Inspektion Vorlaufpumpe O Anlagenvorlauf 1 AuBengewinde D Anschluss Abgasrohr 100mm M Thermomanometer N Bedienpanel Mod EVO T r f r den Zugang zu Feuerraumt r und Aschekasten Stellf Be T r des Pelletbeh lters Knauf des Turbulatorenr ttlers LEGENDE DER OPTIONALEN ELEMENTE AUF ANFRAGE ERHALTLICHES ZUBEHOR S Inspektion Brauchwasservorlaufpumpe OPT T Brauchwasserr cklauf OPT 3 4 Pumpe WARMWASSEREINHEIT MIT PUMPE UND i U Brauchwasservorlauf 3 4 Au engewinde Pumpe W RMETAUSCHER IM KESSEL V Brauchwasserabfluss bei Uberdruck 1 2 Innengewinde WARMWASSEREINHEIT MIT PUMPE IM KESSEL 6 bar ZUS TZLICHER PELLETBEHALTER W Brauchwasserr cklauf OPT 1 2 AuBengewinde FASSUNGSVERM GEN circa 250 k
11. Pay attention to the type of floor and ceiling covering in the place of installation for delicate and flammable materials it is advisable to use adequate thermal diaphragms or panels see par 2 2 3 2 Fume exhaust safety In normal operation the combustion chamber is in a negative pressure guaranteeing seal against any smoke leaks into the room If a certain vacuum level is not reached or the fume exhaust outlet is blocked the vacuum switch detects the lack of a negative pressure inside the combustion chamber or the air flow meter detects a lack of combustion air flow and through the electronic controller switches off the auger rotation motor signalling the anomaly with a message on the control panel AL8 NO NEG PRESS or AL9 INSUF DRAUGHT 3 3 Combustion chamber overpressure safety Any and or sudden combustion fume overpressures inside the chamber and fume exhaust ducts are discharged by opening of the safety valves located above the ash door During normal operation these valves are kept closed by their weight and the negative pressure in the combustion chamber ensuring a seal against any smoke escaping A Periodically check closing the integrity of the device and its operation 3 4 Overheating safety thermostats On the bottom of the hopper and namely on the pellet chute and on the top part of the heating chamber there are two temperature probes connected to the respective safety thermostats that automatically shut off the pelle
12. on line www ufe com direzione e coordinamento della Ferroli spa 66 DOMUSFIRE C29 C35 C39 RECOMMANDATIONS GENERALES 1 1 Introduction 1 2 Comment utiliser ce manuel 1 3 R gles de s curit 1 4 Description technique 1 5 Combustible et usage pr vu 1 6 Accessoires fournis 1 7 Normes de r f rence 1 8 Plaque d identification 1 9 Mise hors service de la chaudi re 1 10 Instructions en cas de n cessit d intervention et de pi ces d tach es 2 TRANSPORT ET INSTALLATION 2 1 Conditions de livraison transport et stockage 2 2 Lieu d installation mise en place et s curit anti incendie 2 3 Prise d air 2 4 Evacuation des fum es de combustion 2 4 1 Types d installations 2 5 Contr le de la position du brasier et des turbulateurs 2 6 Branchement lectrique 2 7 Sch ma lectrique 2 8 Sch ma lectrique pour installation a zones 2 9 Raccordements hydrauliques 2 9 1 Remplissage eau 2 9 2 Caract ristiques eau du circuit 2 9 3 Circuit sanitaire 2 9 4 Sch mas hydrauliques de la chaudi re 2 10 Premi re intervention 3 SYST MES DE PROTECTION DE LA CHAUDI RE 3 1 Distance de s curit par rapport aux mat riaux inflammables 3 2 S curit pour l vacuation des fum es 3 3 S curit en cas de surpression dans la chambre de combustion 3 4 Surchauffe thermostats de s curit 3 5 S curit contre le retour de flamme sur le canal d alimentation en granul s 3 6 Dispositif lectrique de pr
13. sie werden durch eine f r ihre Sicherheit zust ndige Person beaufsichtigt und erhalten von ihr Anweisungen wie das Ger t zu benutzen ist Kinder m ssen beaufsichtigt werden und d rfen weder mit dem Ger t noch im installationsraum spielen Das Netzkabel und gegebenenfalls die Kabel der Au entemperaturf hler m ssen so positioniert werden dass kein Kontakt mit hei en Kesselteilen m glich ist Der Betrieb des Ger ts mit offener T r des Feuerraums und oder des Aschekastens ist verboten Die Einlass ffnungen f r die Verbrennungsluft d rfen nicht verschlossen oder verkleinert werden Der Kessel darf nicht zur Verbrennung verwendet werden er darf ausschlie lich zur Erw rmung des Wassers der Heizungs und oder Warmwasserbereitungsanlage dienen Als Brennstoff sind nur Holzpellets mit den im vorliegenden Handbuch beschriebenen Eigenschaften zul ssig Nicht mit entflammbaren Fl ssigkeiten oder Substanzen anz nden Der Kessel darf nicht zur M llverbrennung verwendet werden W hrend des Betriebs ist der Umgang mit leicht entflammbaren oder explosiven Stoffen in der Nahe des Kessels untersagt Den direkten Kontakt mit den Ger teteilen vermeiden die sich w hrend des Betriebs erhitzen k nnen Vor jeder Wartung den Stecker aus dem Kessel ziehen und nur am kaltem Kessel Eingriffe vornehmen Im Installationsraum muss eine Raumtemperatur zwischen 0 C und 35 C garantiert und eine zu hohe Luftfeuchtigkeit vermiede
14. 0 005 0 040 0 007 0 040 0 009 0 040 Emissions CnHm a 10 gt mg m 6 7 18 8 6 6 18 8 6 7 18 8 Emission CnHm at reference 10 gt Emissions NOx 10 146 7 116 4 147 1 116 4 Emission NOx at reference 10 O gt 24 1 9 5 23 6 9 5 24 5 9 5 Emissions de poussi res 10 O2 Emission dust at reference 10 O 2 0 004 0 029 4 9 13 78 mg m 130 2 116 4 mg m mg m 0 005 0 029 0 006 0 029 mg m 4 8 13 78 4 9 13 78 Emission CnHm at reference 1396 O Emissions NOx 13 Aw 107 84 6 Emission NOx at reference 13 O mg m 94 7 84 6 Emissions CO 13 O2 Emission CO at reference 1396 106 8 84 6 17 6 6 9 Emissions CnHm 13 O 19 66 12 69 Emissions de poussi res 1396 O5 mg m 17 2 6 9 17 8 6 9 Emission dust at reference 13 O 2 Totale des missions de particules PPBT 139605 Total dust emission PPBT at ref 13 mg m 19 22 12 69 19 86 12 69 e 2 3 c E a D DINO 21 3 Glo 3 3 3 5 e o 2 E D a E e D working pressure OIT Jj ojo o DIS cio 5 0 013 BIS zz 0 o dis alsa B18 BS 5 ob LIS o 3 9 210 gt IS ip mis Z ol 3 Q Go Pl j 5 8 NI o S 2 D 5 e o 5
15. 05 Vom Installateur vorgenommene Einstellungen Diese Option ist ausschlie lich dem vom Kundendienst COLA befugten Techniker vorbehalten etwaige willk rliche nderungen k nnen ernste Sch den verursachen und entbinden die Firma COLA Die technischen Parameter im Men 05 d rfen nur von hierzu befugtem Fachpersonal ge ndert werden von jeder Haftung 121 DOMUSFIRE C29 C35 C39 4 7 Externer Thermostat Uhrenthermostat Wenn ein externer Thermostat verwendet werden soll wenden Sie sich bitte an einen befugten Techniker der bei der Installation die folgenden Anleitungen befolgen muss Ger t mit dem Hauptschalter an der R ckseite ausschalten und Netzkabel trennen Die seitliche Verkleidung abnehmen um die elektronische Regelung freizulegen Unter Bezugnahme auf den elektrischen Schaltplan die zwei Kabel des Thermostats an die Klemmen TERM der Platine anschlieBen Alles wieder einbauen und den korrekten Betrieb kontrollieren Bei jeder Einstellung ndern sich die anderen Funktionen des Men s nicht und die Anzeige des Anschlusses erfolgt durch Aufleuchten der LED Segmentanzeige an der Statusleiste auf dem Display Sobald der Wert erreicht wird schaltet der Thermostat den Kessel ab und auf dem Display wird die Funktion STANDBY angezeigt sofern aktiv 4 10 AuBerbetriebnahme Ende der Heizperiode Wird der Kessel f r l ngere Zeit nicht benutzt und oder am Ende der Heizperiode folgenderma en vorgehen Den Pelletb
16. 16 Porta cenere 17 Cassetto cenere 18 Termocamera 31 DOMUSFIRE C29 C35 C39 COLA Rappresentazioni esplose di 1 Gruppo braciere 2 Gruppo estrattore fumi 3 Gruppo coclea Legenda 1 Bracere 2 Portabracere 3 Deviatore interno 4 Tubo aspirazione aria 5 Resistenza elettrica 6 Guarnizioni 7 Debimetro Legenda 1 Voluta estrattore fumi 2 Guarnizione termica 3 Motore estrattore fumi 4 Tubo espulsione fumi 5 Guarnizione Legenda 1 Guarnizione serbatoio convogliatore 2 Flangia ferma motoriduttore 3 Motoriduttore 4 Coclea 5 Guarnizione per scivolo 6 Scivolo caduta pellet 7 Guarnizione camera convogliatore 8 Convogliatore pellet 32 DOMUSFIRE C29 C35 C39 6 4 Componenti elettrici 269 2 900 6 5 Componenti idraulici di serie CCLA Legenda 1 Pannello comandi mod EVO 2 Termostati di sicurezza Temperatura 3 Interuttore ON OFF con fusibili 4 Scheda elettronica 5 Cavo alimentazione elettrica 6 Vacuostato 7 Trasduttore di pressione circuito idraulico 7 Sonda fumi 8 Sonda acqua termo camera 9 Sonda acqua boiler puffer 10 Sonda livello su serbatoio pellet 11 Connessione seriale 12 Trasduttore di pressione Legenda 1 Vaso espansione a membrana 2 Rubinetto scarico impianto da 12 3 Valvola di sicurezza pressione 4 Tubo mandata con attacchi da 1 5 Circ
17. 5 Boiler class rif EN303 5 201 2 Water resistance AT 10K 521 7 624 7 Water resistance T 20K o 3 oO D A 4 D 134 3 62 6 148 6 62 6 159 5 62 6 14 1 5 4 16 3 5 4 18 2 5 4 10 14 0 10 0 14 Fume outlet temperature o S a D N a o 3 c 5 0 D d o d a a d i d d 4 5 ur SIS a D Pool o o si o d o D gt gt a 3 1 N adi Al A o e bd Q o Tirage fum e min max Draught min max lt c a lt o 5 5 a v 3 D v 100 230V 50Hz 6A Alumage Start 476 Stand by 4 P nen 160 P rid 153 1300 x 700 x 1300 x 700 x 1300 x 700 x 698 698 698 puissance nominale et de faible puissance Nominal output and Reduced output La consommation de granul s peut varier selon le type de pellet utilis Pellet consumption can vary according to the type of pellets used Dimensions HxLxP 5 a n a 5 D E g o ea Olm 2In Sla 913 2 2 318 213 als SIS 218 ajs 215 3 2 R78 s 213 S 2 3 813 als I 2 5 215 x el 3 0 Tis E x Si 2 ol 2 lt COLA s rl Viale del Lavoro 7 9 37040 Arcole VR Italy Tel 045 7635780 045 6144043 Cod Fisc P IVA e Iscr
18. Cine alatare Circulador tissa a al Vaso de expansi n con membrana FECERO Llave valvula de corte Valvula antirretorno Mancia Gil icona B Valvula de seguridad Pmax 3 bar V lvula de Seguridad Pm x 6 bar Termostato T gt 85 A IDA a calefacci n 1 M B RETORNO de calefacci n 1 M C IDA agua sanitaria 3 4 M D RETORNO agua sanitaria 3 4 M E Entrada agua de red 1 2 H Descarga de agua sobrepresi n 1 2 H Fi aria Flujostato Crui dada AEEA e essais Intercambiador de placas para AS Untuata all bilanciamento claritos Valvulas de equi lo del circuito unive Lermne in tia ura Valvula termostatica automatica Sensor de seguridad T gt 85 C Nonenro Tomnerarirn arm n Sensor de temperatura agua Sensor de presi n circuito durante el montaje no entregadas con el equipo 142 DOMUSFIRE C29 C35 C39 COLA Esquema hidr ulico de la caldera de pellets con intercambiador de placas para agua sanitaria_07 2012 Caldera de pellets Termostato Ta 0 Sistema ENTRADA control Camara t rmica pellets IDA a calefacci n 1 IDA agua sanitaria 1 2 M RETORNO agua sanitaria 1 Entrada agua de red 1 2 H Descarga de agua sobrepresi n 1 2 H LEYENDA Llave de descarga a Flujostato 2 Sensor de presi n man metro a Intercambiador de placas para AS or e Circulador 3 V
19. DISPLAY NAAN Hag M dd 3MO3NHOS AAA DRUCKMESSUMFORME E EXT RAUMT FUHL FE He AUSSENTHERM DSS 2 ABGASF HLER FUHLER H20 BOILER PUFFER i EEE eR eR EER 1173N09 SLIOZITABSZIY f DEP 312111 gar ENZ 4 AMOANHOS INI 1313d4 H9IS pu DU SIY WHO zi Leiw l II 3svoav e a nl DOMUSFIRE C29 C35 C39 109 COLA 2 8 Elektroschaltplan einer Mehrzonen Anlage Vor der Installation des Kessels muss festgestellt werden was f r eine Heizungsanlage vorhanden ist gibt es mehrere Anlagenabschnitte muss eine als Optional erh ltliche elektronische Mehrzonensteuerung installiert werden Nur so kann eine berhitzung des Ger ts durch ein eventuelles gleichzeitiges Schlie en der Abschnittsventile und eine daraus resultierende Blockierung des Warmwasserzuflusses verhindert werden 2 9 Wasseranschl sse Die W rmeleistung des Ger ts ist vorab mit einer Berechnung des W rmebedarfs des Geb udes gem den geltenden Bestimmungen und nach R cksprache mit einem Fachtechniker zu ermitteln Gem der italienischen Norm UNI 10412 2 2009 und den anerkannten Regeln d
20. Esto es necesario para garantizar la depresi n de la c mara de combusti n La limpieza ordinaria debe ser realizada por el usuario como se indica en el manual El mantenimiento extraordinario debe ser efectuado al menos una vez al a o por un Centro de asistencia autorizado Limpie todas las partes con la caldera completamente fr a y desconectada de la red el ctrica A Deseche los residuos de la limpieza seg n las normas locales vigentes Esta prohibido poner la caldera en marcha sin los revestimientos exteriores Evite la formaci n de humo inquemados durante el encendido y el funcionamiento A continuaci n se detallan las operaciones de control y mantenimiento necesarias para asegurar el funcionamiento correcto de la caldera 2 1 ano Partes Frecuencia 1 d a 2 3 d as 1 mes 2 3 meses ji extraordinaria Tipo de limpieza limpieza limpieza limpieza limpieza efectuada por el Centro de ordinaria ordinaria ordinaria ordinaria vel asistencia t cnica Brasero Haz de tubos de la camara 8 t rmica Colector extractor de humos Juntas puertas c mara y cenicero Chimenea tubo de humos 5 1 Limpieza de brasero y portabrasero Extraiga el brasero y quite los residuos de ceniza depositados en la c mara de combusti n y en el portabrasero Para esto puede utilizar un aspirador Esta operaci n se debe realizar a diario sobre
21. LE 9318000 11NVH9 d EJ 30 AWN Ad3Sdu SNVS SIA y E A E PRESSION H20 SONDE AMB EXT A SONDE THERMIQUE N DES FUMEES 1173N09 SLIOZITABSZIO IN8 SONDE H20 CHAUFF lectrique Tow r oe E Se DH emae 2 7 Sch DOMUSFIRE C29 C35 C39 77 COLA 2 8 Sch ma lectrique pour installation a zones Avant d installer la chaudi re dans l habitation v rifier la typologie de l installation de chauffage si elle compte plusieurs zones il faudra pr voir une unit lectronique pour circuits multizones disponible en option Ceci pour viter de surchauffer la chambre de combustion au cas o les vannes de zone se fermeraient simultan ment entra nant par la m me occasion l arr t du d bit d eau chaude 2 9 Raccordements hydrauliques La puissance thermique de la chaudi re doit tre d termin e au pr alable par un calcul des besoins thermiques de l difice selon la r glementation en vigueur Faire appel un technicien sp cialis pour cette op ration Selon la norme italienne UNI 10412 2 2009 et la bonne techni
22. M 1 3 26 Vendredi Prog 3 M 1 3 27 Samedi prog 3 M 1 3 28 Dimanche Prog 3 M 1 3 29 Start Prog 4 M 1 3 30 Stop Prog 4 M 1 3 31 Lundi Prog 4 M 1 3 32 Mardi Prog 4 M 1 3 33 Mercredi Prog 4 M 1 3 34 Jeudi Prog 4 M 1 3 35 Vendredi Prog 4 M 1 3 36 Samedi prog 4 M 1 3 37 Dimanche Prog 4 M 4 2 01 Chrono Week End ON OFF Program M 4 2 02 Start 1 Week End M1 4 Week End M 4 2 03 Stop 1 Week End M 4 2 04 Start 2 Week End M 4 2 05 Stop 2 Week End Consigne Horloge Menu 02 M 2 2 Mode Veille ON OFF R glages M 2 3 Charge initiale ON OFF Type de 4 utilisateur M 2 4 granul s R glage granul s 9 9 M 2 5 rg Reglage granules ON OFF M 3 1 Langue M 3 3 Mode Buzzer ON OFF M 3 4 Eclairage 0 100 Consigne Menu 03 M 3 6 Temp Ballon 40 80 Consigne Puffer Utilisateur Delta Ballon M 3 7 Puffer 0 5 20 Niveau M 3 8 granul s ON OFF M 3 9 Valide ECS ON OFF Menu 04 Etat a Chaudi re menu pour le technicien Menu 05 R glages menu pour le technicien Installateur 87 DOMUSFIRE C29 C35 C39 4 6 1 menu 01 Valeurs du chrono Permet de valider ou de d sactiver toutes les fonctions du chronothermostat En s lectionnant ON la fonction est valid e et le segment Led D correspondant s affiche Lorsque la programmation Quotidienne Hebdomadaire ou Week end est ins r e dans la partie sup rieure de l cran le segment Led correspondant C s affiche a droite Quant aux s lections et a la saisie d
23. Reg Impr 02990180230 Capitale Sociale Euro 52 000 00 i v R E A VR 301021 Socio Unico Fax Amministrazione 045 6100317 Fax Commerciale 045 7639032 Fax Assistenza 045 7639030 Fax Logistica 045 6144048 email info anselmocola com on line www colastufe com direzione e coordinamento della Ferroli spa 98 DOMUSFIRE C29 C35 C39 1 ALLGEMEINE HINWEISE 1 1 Vorwort 1 2 Nachschlagen im Handbuch 1 3 Sicherheitsvorschriften 1 4 Technische Beschreibung 1 5 Brennstoff und zul ssiger Gebrauch 1 6 Mitgeliefertes Zubeh r 1 7 Bezugsnormen 1 8 Typenschild 1 9 Au erbetriebsetzung des Kessels 1 10 Anleitungen f r Eingriffsanforderungen und Ersatzteilbestellungen 2 TRANSPORT UND INSTALLATION 2 1 Liefer Transport und Lagerbedingungen 2 2 Aufstellungsort Aufstellung und Brandschutz 2 3 Lufteinlass 2 4 Abgasf hrung 2 4 1 Installationsarten 2 5 Positionskontrolle von Brenntopf und Turbulatoren 2 6 Elektrischer Anschluss 2 7 Elektroschaltplan 2 8 Elektroschaltplan einer Mehrzonen Anlage 2 9 Wasseranschl sse 2 9 1 Bef llen der Anlage mit Wasser 2 9 2 Eigenschaften des Anlagenwassers 2 9 3 Anlage f r Warmwasserbereitung 2 9 4 Anschlusspl ne Kessel 2 10 Notfallma nahmen 3 SICHERHEITSEINRICHTUNGEN DES KESSELS 3 1 Sicherheitsabstand von entflammbaren Materialien 3 2 Sicherheitsvorrichtung Abgasf hrung 3 3 Uberdruckventil in der Brennkammer 3 4 Uberhitzung Thermostate 3 5 Flammenr ckschlagschutz
24. Verificare la causa dello Avviene nel caso di intervento pee AL 7 del termostato di sicurezza superiore alla soglia di eccessivo surriscaldamento SICUREZ della temperatura canale taratura per un Sbloccare il termostato TERMICA caci n surriscaldamento della parte interessato al Il sistema viene arrestato inferiore del serbatoio bloccando il funzionamento del motoriduttore surriscaldamento agendo sul pulsante di ripristino 34 DOMUSFIRE C29 C35 C39 COLA Segnalazione Anomalia Cause possibili Rimedi Verificare la pulizia del condotto A fumario e della camera di La camera di combustione combustione _ E Sporca us ALB una pressione inferiore alla soglia condotto fumi ostruto ao MANCA di taratura del vacuostato m ee ou Verificare la chiusura delle DEPRESS sistema viene arrestato valvole antiscoppio M a difettoso Altre operazioni di ripristino devono essere condotte centro di assistenza Verificare la pulizia del condotto La camera di combustione N della camera d sporca QE AL 9 Compare quando il flusso d aria Il condotto fumi ostruito LD chiusura EE TIRAGGIO comburente sotto una La porta fuoco non chiusa En n gu INSUFF soglia Le valvole antiscoppio sono Ipsis HESE ETS valvole antiscoppio aperte inceppate Altre operazioni di ripristino Il de
25. il doit tre chemin e anii verit a D tanche aux produits de combustion isol et calorifug en fonction de ice os auquel il est destin de il doit tre le plus droit possible avec des d voiements dont l angle de SP ceux ci avec la verticale doit tre 45 Conduit de respecter une distance de s curit minimale cart de feu avec les eve mat riaux combustibles de la construction par interposition d une lame d air Chambiede ou doublage avec des mat riaux isolants F visite il doit avoir de pr f rence une section interne circulaire uniforme sur toute b Y ci S iod Prise d air sa hauteur libre et ind pendante ext rieur 100 il doit si possible comporter une chambre de visite pour collecter les Distance mini 0 2 m cm mini mati res solides suies et les condensats ventuels situ e a l embouchure du conduit de raccordement ou carneau CARNEAU ou CONDUIT DE RACCORDEMENT conduit ou l ment de raccordement entre l appareil et le conduit de fum e pour l vacuation des produits de combustion Prescriptions techniques du CARNEAU il ne doit pas traverser des locaux o l installation d appareils de combustion est interdite l usage de conduits m talliques flexibles ou en fibrociment est interdit l utilisation d l ment a contre pente est interdite le s troncon s horizontal aux du conduit doit doivent avoir une pente minimale
26. in particolare per assenza o difetto di manutenzione periodica inadeguatezza o mancanza delle manutenzioni periodiche inadeguate o mancanti previste sui manuali d uso e manutenzione a corredo dello prodotto anormalit o anomalie di qualsiasi genere nell alimentazione degli impianti elettrici idraulici e o negli scarichi in canna fumaria impiego di combustibili non conformi e non riportati sui manuali d uso e manutenzione impiego di parti di ricambio non originali COLA corrosioni da condensa o aggressivit dell acqua causati da inadeguati trattamenti dell acqua di alimentazione o dall errato utilizzo di trattamenti disincrostanti deterioramento da agenti chimico fisici gelo correnti vaganti fulmini fenomeni atmosferici trascuratezza cattivo utilizzo manomissioni o interventi tecnici effettuati sul prodotto da personale non autorizzato estraneo alla rete dei Centri Assistenza autorizzati parti soggette a normale usura di impiego guarnizioni manopole vetro parti in vermiculite refrattario parti estetiche in metallo o ceramica maiolica braciere deviatori fiamma fumo ecc eventuali interventi di taratura o regolazioni sull apparecchio per la sostituzione della qualit del pellet o modifica dell installazione cause di forza maggiore indipendenti dalla volont e dal controllo dell azienda Produttrice Non rientrano nella Garanzia le operazioni ordinarie di pulizia e manutenzione n eventuali attivit
27. just press the button P4 for about 2 seconds The auger is immediately stopped and the fume extractor is brought to high speed making the message FINAL CLEANING appear on the display Storage tank or Puffer H20 1436 SEC CLEAn Dialogue box At the end of the operation the message OFF appears in the dialogue box During the shutdown stage the boiler cannot be restarted until the fume temperature has fallen below a set value for a fixed time with the message WAITING COOL appearing in the dialogue box Dialogue box 55 DOMUSFIRE C29 C35 C39 COLA 4 9 Menu Press button P3 SET to access the menu this is divided into various items and levels for accessing the settings of the electronic controller The following table summarises the menu structure with the selections available to the user Menu 01 Set M 1 1 Enable Chrono M 1 1 01 Enable Chrono ON OFF Chrono M 1 2 01 Day Chrono M 1 2 02 Start 1 Day M1 2 Day Program M 1 2 03 Stop 1 Day M 1 2 04 Start 2 Day M 1 2 05 Stop 2 Day M 1 3 01 Week Chrono ON OFF M 1 3 02 Start Prog 1 M 1 3 03 Stop Prog 1 M 1 3 04 Monday Prog 1 M 1 3 05 Tuesday Prog 1 M 1 3 06 Wednesday Prog 1 M 1 3 07 Thursday Prog 1 M 1 3 08 Friday Prog 1 M 1 3 09 Saturday
28. rature la chaudi re s teint et la fonction VEILLE s affiche sur le panneau si elle a t valid e 4 8 P riode d inactivit fin de saison Si la chaudi re n est pas utilis e pendant de longues p riodes et ou la fin de chaque saison il est conseill de proc der de la fa on suivante vider compl tement le r servoir granul s d brancher le cordon d alimentation de la chaudi re nettoyer parfaitement et si n cessaire remplacer les parties ventuellement endommag es par un professionnel qualifi prot ger la chaudi re contre la poussi re avec une b che ou housse ou tout autre dispositif d une efficacit au moins quivalente ranger la chaudi re dans un endroit sec et l abri des intemp ries 90 DOMUSFIRE C29 C35 C39 COLA 5 NETTOYAGE DE LA CHAUDI RE Il est important de nettoyer la chaudi re pour viter la mauvaise combustion le d p t de cendres et d imbr l s dans le foyer et la r duction de l efficacit thermique Les portes du foyer et du cendrier doivent toujours tre ferm es lorsque la chaudi re est allum e Contr ler r guli rement les joints des portes pour viter toute infiltration d air car elles doivent garantir la d pression de la chambre de combustion Les op rations de nettoyage courant doivent tre normalement effectu es par le client en suivant les indications du manuel L entretien extraordinaire est par contre effectu par le centre d
29. 005 0 040 0 007 0 040 0 009 0 040 Emisiones de CnHm al 10 O Emission CnHm at reference 10 gt Emisiones de NOx al 10 O Emission NOx at reference 10 O Emisiones de polvo al 10 O Emission dust at reterence 10 gt Emisiones de CO al 13 2 Emission CO at reference 13 6 7 18 8 6 6 18 8 6 7 18 8 146 7 116 4 147 1 116 4 130 2 116 4 24 1 9 5 23 6 9 5 245 9 5 0 004 0 029 0 005 0 029 0 006 0 029 Emisiones de CnHm al 13 O Emission CnHm at reference 13 O gt 4 9 13 78 4 8 13 78 4 9 13 78 Emisiones de NOx al 1396 O Emission NOx at reference 1396 O 106 8 84 6 107 84 6 94 7 84 6 misiones de polvo al 1396 O Emission dust at reference 13 O gt Total de emisiones de particulas PPBT al 13 O Total dust emission PPBT at ref 1396 O Temperatura max agua establecer Set max temp 17 6 6 9 17 2 6 9 17 8 6 9 19 66 12 69 19 22 12 69 19 86 12 69 Presi n maxima de funcionamiento Max working pressure Capacidad de la camara t rmica Heating chambre capaci Capacidad del dep sito Pellet stove capacity 80 3 30 68 Clase de caldera rif EN303 5_2012 Boiler class rif EN303 5 2012 P rdida de carga en lado del agua AT 10K Water resistance AT 10K P rdida de carga en lado del agua AT 20K Water resistance AT 20K Temperatura salida humos Fume outlet temperature 134 3 62 6 148 6
30. 2 2 Installationsort Aufstellung und Brandschutz Nach Vorbereitung des Wasser und des Stromanschlusses durch einen qualifizierten Techniker die Verpackung ffnen den Kessel von der Palette nehmen und am gew hlten Standort aufstellen Dieser muss den in diesem Handbuch genannten Vorschriften entsprechen Der Kessel muss sehr vorsichtig an der gew nschten Stelle abgestellt werden St e sind zu vermeiden Au erdem unbedingt die Tragf higkeit des Fu bodens in Bezug auf das Kesselgewicht pr fen und gegebenenfalls einen Fachmann zu Rate ziehen Nach Entfernen der Verpackung und der Schutzfolie vorsichtig vorgehen um die mechanischen und elektrischen nicht mit St en oder Wasserspritzern zu besch digen Der Aufstellungsraum muss ausreichend bel ftet sein damit eine Austragung eventueller geringf giger Abgasaustritte gew hrleistet ist Das Ger t eignet sich f r den Einsatz in technischer Umgebung mit einer Mindesttemperatur von 0 C und wird komplett mit Frostschutzfunktion geliefert mit der die Heizpumpe aktiviert wird sobald das Wasser in der Anlage unter 6 C sinkt um die Heizkammer sowie den Heiz und Brauchwasserkreis zu sch tzen Allerdings funktioniert die Frostschutzfunktion nur wenn der Kessel mit Spannung versorgt ist Der Kessel muss au erdem mit Luftspalt oder isolierendem Zwischenraum in ausreichendem Abstand von entflammbarem Material oder Brennstoffen getrennt werden des Weiteren ist zu beachten dass Fu b den un
31. 6 C salvaguardando termocamera circuito di riscaldamento sanitario La funzione antigelo attiva solo a caldaia alimentata elettricamente La caldaia deve inoltre essere opportunamente distanziata da materiali infiammabili o combustibili con intercapedini d aria o l utilizzo di idonee protezioni isolanti va inoltre precisato che pavimenti e o soffiti coperture di materiale infiammabile o sensibili al calore devono essere protetti da pannelli protettivi di materiale isolante Verificare che nel locale tecnico d installazione vi siano gli spazi laterali e posteriori alla Caldaia necessari per la manutenzione e la pulizia dello stesso apparecchio dei condotti dei fumi di scarico e della canna fumaria Verificare inoltre che il serbatoio pellet sia facilmente accessibile per il caricamento del combustibile Le distanze minime di manutenzione e di sicurezza devono rispettare la tabella di seguito riportata SERBATOIO AGGIUNTIVO OPZIONALE A 500 mm B 500 mm C 500 mm D 1000 mm L 1450 mm P 700 mm 12 DOMUSFIRE C29 C35 C39 COLA Comignolo antivento Canna fumaria Sportello ispezione su canna fumaria Presa d aria a parete min 100 cm Raccordo a con tappo d ispezione La caldaia fornita di 4 piedini regolabili per facilitare il posizionamento in presenza di pavimenti non perfettamente planari per regolare l altezza inclinare quanto necessario l
32. 60335 2 102 Seguridad de aparatos electrodom sticos y similares parte 2 Norma CEI EN 55014 1 Resistencia electromagn tica Requisitos para electrodom sticos herramientas el ctricas y equipos el ctricos similares Parte 1 Emisi n de interferencias Norma EN 55014 2 Resistencia electromagn tica Requisitos para electrodom sticos herramientas el ctricas y equipos el ctricos similares Parte 2 Inmunidad Normas de familia de producto Norma CEI EN 61000 3 2 L mites de emisi n de corrientes arm nicas corriente de entrada lt 16 A por fase Norma CEI EN 61000 3 3 Limitaci n de las variaciones de tensi n y flicker en las redes p blicas de suministro de baja tensi n para los equipos con corriente nominal lt 16 A Norma CEI EN 62233 M todos de medida de los campos electromagn ticos de electrodom sticos y similares en relaci n con la exposici n humana Normas DIN plus 51731 EN 14961 2 Norm M 7135 Normas sobre las especificaciones y clasificaci n del pellet 1 8 Placa de identificaci n La placa de identificaci n est en la cara interna de la tapa del dep sito de pellets o en la pared posterior de la caldera En ella se enumeran todos los datos t cnicos de la tabla par 1 4 1 9 Puesta fuera de servicio de la caldera Cuando decida no utilizar m s el equipo descon ctelo de la red el ctrica y vac e el dep sito de pellets Para desechar la caldera ll vela en un embalaje robusto y precintad
33. AL 4 Lun Das Saugzuggeblase ist blockiert Die Vorg nge zur Wiederherstellung SAUGZUGG EL Der Drehzahlsensor ist defekt des Kesselbetriebs m ssen von einer z ib puis Das Saugzuggeblase wird nicht mit autorisierten Kundendienststelle Farei DAG Wird aktiviert Strom versorgt durchgef hrt werden Kontrollieren ob der Beh lter Pellets AL 5 Der Pelletbeh lter ist leer enth lt m gt si Der Heizwiderstand ist defekt Die Einschaltvorgange kontrollieren ZUNDUNG EN ce nee verschmutzt oder nicht in der korrekten Andere Vorg nge zur _ P x Position eingebaut Wiederherstellung des FEHLGESCH Der Abschaltvorgang wird aktiviert Falsche Einstellung der Kesselbetriebs m ssen von einer LAGEN Pelletbeschickung autorisierten Kundendienststelle durchgef hrt werden Kontrollieren ob der Beh lter Pellets BES Der Pelletbeh lter ist leer enthalt KEINE Der Getriebemotor det Pelletzuf hrung einstellen PELLETS e wira ni htimit Pellets Pelletbeschickung muss sich einlaufen eee vul Der Getriebemotor f hrt keine VORHANDE Pellets Kesselbetriebs m ssen von einer N ALE urchgef hrt werden Der Uberhitzungsschutz eine 1 un AL 7 Es findet im Fall der Intervention der Temperatur oberhalb der Schwelle Nach der Ursache f r die ONU Uberhitzung suchen Sicherheits Thermostat Temperatur Sollwert f r eine Uberhitzung des Dan Betrieb doe vom dar Kanal Cochlea unteren Teils des R
34. C29 C35 C39 COLA 4 13 Betriebsphase Nach erfolgreichem Abschluss des ZUNDVORGANGS wechselt der Kessel auf den normalen Betriebszustand BETRIEB Der Benutzer kann die Heizleistung mit den Tasten P6 und P5 von der h chsten Heizstufe 5 bis zur kleinsten Heizstufe 1 regeln Die Aktivierung ON der Funktion Brauchwasserkreis wird durch Einblenden des LED Segments A angezeigt Sollleistung 3 aufgrund von Brennstoffmangel erlischt Zum Einf llen der Pellets muss der Kessel ausgeschaltet sein Die Abdeckung des Pelletbeh lters muss immer geschlossen bleiben und darf nur zum Einf llen des Brennstoffs ge ffnet werden Die Pellets cke m ssen in mindestens 1 5 m Entfernung vom Kessel aufbewahrt werden q Unbedingt den F llstand der Pellets im Beh lter kontrollieren um zu vermeiden dass die Flamme 4 4 1 Wassertemperatur Sollwert ndern Zum ndern der Wassertemperatur durch Dr cken der Taste P3 die Option MENU 03 w hlen dann die Tasten P1 und P2 zu geben 5 5 jj m MENU M 3 6 und die gew nschte Temperatur eingestellt Sobald de Wassertemperatur den eingestellten Wert bzw die Abgastemperatur den eingestellten H chstwert erreicht wird die f SEE iP Leistung automatisch auf die Mindeststufe gesetzt und der Li ASSER Betriebszustand MODULATION aktiviert ANI Sobald die Abgastemperatur den vorgegebenen H chstwert erreicht erscheint auf dem Bedienpanel die Meldung MODULIEREN
35. COLA Medidas de las calderas de pellets mod DOMUSFIRE C29 DOMUSFIRE C35 DOMUSFIRE C39 DETALLE A LEYENDA Conexi n del cable el ctrico 8 Descarga de agua en sobrepresi n 1 2 H 3 bar Retorno de calefacci n 1 M Aspiraci n de aire comburente 60 mm Conexi n a red de agua 1 2 H Descarga de agua de la instalaci n Descarga de aqua de la instalaci n B Conexi n de ida sin bomba 1 M D Inspecci n de la bomba de ida O da a calefacci n 1 M Conexi n del tubo de salida de humos Y 100 mm M Termoman metro Panel de mandos mod EVO O Puerta de acceso a puertas de c mara y cenicero P Pies regulables del dep sito de pellets Pomos para sacudir los turbuladores LEYENDA DE LOS ELEMENTOS OPCIONALES ACCESORIOS A PEDIDO S Inspecci n bomba de ida a sanitario OPC GRUPO AGUA SANITARIA CON BOMBA E T Retorno agua sanitaria OPC 3 4 bomba INTERCAMBIADOR DENTRO DE LA CALDERA U Ida agua sanitaria OPC 3 4 M bomba GRUPO AGUA SANITARIA CON BOMBA DENTRO V Descarga de agua en sobrepresi n ACS 1 2 H 6 bar DE LA CALDERA W Retorno agua sanitaria OPC 1 2 M intercambiador DEPOSITO AUXILIAR DE PELLETS CAPACIDAD Z Ida agua sanitaria OPC 1 2 M intercambiador aprox 250 kg 134 DOMUSFIRE C29 C35 C39 COLA Apertura y cierre de la puerta de la camara de combustion en la caldera DOMUSFIRE Para a
36. Fax Assistenza 045 7639030 Fax Logistica 045 6144048 gpega email info anseimocola com on line www colastufe com direzione e coordinamento della Ferroli spa 36 DOMUSFIRE C29 C35 C39 GENERAL INFORMATION 1 1 Introduction 1 2 Using the manual 1 3 Safety rules 1 4 Technical description 1 5 Permissible use and fuel 1 6 Accessories supplied 1 7 Reference standards 1 8 Data plate 1 9 Boiler decommissioning 1 10 Instructions for requesting assistance and replacement parts 2 TRANSPORT AND INSTALLATION 2 1 Conditions of supply transport and storage 2 2 Place of installation positioning and fire prevention safety 2 3 Air inlet 2 4 Fume exhaust 2 4 1 Types of installation 2 5 Brazier and turbulator position check 2 6 Electrical connection 2 7 Wiring diagram 2 8 Wiring diagram for zone system 2 9 Plumbing connections 2 9 1 System water filling 2 9 2 System water characteristics 2 9 3 DHW system 2 9 4 Boiler hydraulic diagrams 2 10 Emergency 3 BOILER SAFETY 3 1 Safety distance from flammable materials 3 2 Fume exhaust safety 3 3 Combustion chamber overpressure safety 3 4 Overheating thermostats 3 5 Safety against flareback in the pellet chute 3 6 Overcurrent electrical protection device 3 7 Water circuit overpressure safety 3 8 Fume extractor fan failure 4 BOILER USE 4 1 Introduction 4 2 Description of control panel 4 3 Lighting 4 3 1 Check before lighting 4 3 2 Startup stage 4 4 Work stage 4 4 1 M
37. Kessel abschalten Alarmursache beheben und erst dann den Kessel wie im vorliegenden Handbuch beschrieben wieder einschalten Jeder Alarmzustand hat die sofortige Abschaltung des Kessels zur Folge Nachstehend sind die eventuell am Bedienpanel angezeigten Alarme mit Ursache und Abhilfe aufgef hrt COLA ALARME MELDUNGEN Anzeige Betriebsst rung M gliche Ursachen Abhilfen Den Kessel durch Dr cken der Taste P4 auf OFF stellen und den AL 1 Einschaltvorgang wiederholen _ Keine Stromversorgung wahrend Andere Vorg nge zur STROMAUS SEENEN des Z ndvorgangs Wiederherstellung des FALL Kesselbetriebs m ssen von einer autorisierten Kundendienststelle durchgef hrt werden AL 2 Wird ausgel st bei Defekt des Der F hler ist defekt n Vorg nge zur Wieder herstellung 3 ur des Kesselbetriebs m ssen von einer ABGASFUHL Abgastemperaturf hlers Der F hler ist nicht an der Platine Der Abschaltvorgang wird aktiviert angeschlossen gang i 9 durchgeftihrt werden Pelletzuf hrung einstellen AL 3 Wird ausgel st wenn der berm ige Pelletf llung Andere Vorg nge zur HOT Abgastemperaturf hler eine Reduzierter W rmeaustausch Wiederherstellung des Kesselbetriebs Abgastemperatur ber 280 C misst in der Anlage m ssen von einer autorisierten ABGASE Der Abschaltvorgang wird aktiviert Kundendienststelle durchgef hrt werden
38. M 1 3 35 Freitag Prog 4 M 1 3 36 Samstag Prog 4 M 1 3 37 Sonntag Prog 4 M 4 2 01 Uhrenthermostat Wochenende ON OFF M 4 2 02 Start 1 Wochenende M1 4 Program Wochenende M 4 2 03 Stop 1 Wochenende M 4 2 04 Start 2 Wochenende M 4 2 05 Stop 2 Wochenende M 2 1 Uhr einstellen Men 02 Vom M 2 2 Standbybetrieb ON OFF Benutzer M 2 3 Erste Pelletf llung ON OFF vorgenommene M 2 4 Pellettyp Einstellung Pellet 9 9 Einstellungen M 2 5 on Einstellung Pellet ON OFF M 3 1 Sprache M 3 3 Modus Summer ON OFF M 3 4 Beleuchtung 0 100 e umana M36 Solltemp Boiler Puffer 40 80 Einstellungen M 3 7 Delta Boiler Puffer 0 5 20 M 3 8 Pelletf llstand ON OFF M 3 9 Warmwasserbereitung ON OFF aktivieren Men 04 Betriebszustand Technikermen Kessel Men 05 vom Installateur Technikermen vorgenommene Einstellungen 119 DOMUSFIRE C29 C35 C39 4 6 1 Menu 01 Uhrenthermostat einstellen Dient zur Aktivierung und Deaktivierung aller Funktionen des Uhrenthermostats Mit der Wahl von ON wird die Funktion aktiviert und das entsprechende LED Segment angezeigt D Bei Eingabe der Tages Wochen oder Wochenendprogrammierung wird im oberen Displayabschnitt jeweils das entsprechende LED Segment eingeblendet Was die Auswahl der Optionen und die Eingabe der Uhrzeiten betrifft m ssen die sechs Tasten gem den Anleitungen in der Tabelle von Absatz 4 2 bet tigt werden Bei ffnen des Untermen s PROGRAM TAG k nnen die t glich
39. MODULATION function when the temperature exceeds the SET value Initial load Setting this function allows activation of gearmotor operation with the boiler off or cold for pellet preloading of 90 sec It starts with button P1 and stops with button P4 Pellet type With the function on press the buttons P1 or P2 to increase or reduce pellet loading to optimise consumption and combustion depending on the type of pellets used Initial load auger 2 Setting this function allows activation of gearmotor operation relevant to the supplementary hopper for a fixed preload It starts with button P1 and stops with button P4 4 6 3 Menu 03 User setting With this menu it is possible to carry out the following settings Language With this selection it is possible to select the dialogue language from those available entered in the menu and namely ITALIAN FRENCH ENGLISH GERMAN SPANISH Buzzer With this selection it is possible to activate deactivate boiler acoustic signalling Lighting With this selection it is possible to change the brightness of the backlit display from a minimum of 0 to a maximum of 100 Storage tank Puffer Temp setting It is possible to select the hot water storage tank SET temperature for heating or both from a minimum of 40 C toa maximum of 80 C Storage tank Puffer Delta With this selection it is possible to set the temperature difference between boiler shutdown and the next restart from a
40. Une fois entr dans le menu il est possible d obtenir les diff rentes options de visualisation et d effectuer les param trages et ou r glages disponibles suivant le niveau d acc s Le tableau ci apr s indique les commandes et les messages correspondants affich s pendant la phase de programmation ou pr s lection des param tres de fonctionnement bouton d signation mode action cran sup rieur cran inf rieur limites air 7 C e Augmente la valeur de la temp rature du Z 40 C eau SET TEMPERATURE thermostat EAU et d AMBIANCE SET H2O air Temp rature 30 C 80 Augmentation 1 de la 5 temp rature PROGRAMMATION Augmente le param tre s lectionn ra Valeur param tre P Temp rature des Temp rature de _ FONCTIONNEMENT Affiche la temp rature Auges ieni air 7 C 2 Diminue valeur de temp rature du A 40 C eau SET TEMPERATURE mel cem emper SET H2O air Temp rature 30 C 80 2 Diminution de la temperature PROGRAMMATION Diminution du param tre s lectionn ne Valeur param tre FONCTIONNEMENT Affiche l tat op rationnel de la chaudi re Pression surle r gime ventilateur circuit de l eau fum es Donne acc s au SET de la temp rature et au menu des param tres utilisateur et 3 3 Set Menu technicien en appuyant dessus plusieurs SET param tre Temp rature valeur fois Appuyer dessus 2 secondes pour allumer Affiche l tat FONCTIONNEMENT ou teindre
41. Verwendung von Metallschl uchen oder Rohren aus Asbestzement ist verboten die Verwendung von Elementen mit Gegenneigung ist verboten in den waagerechten Abschnitten darf der Kanalverlauf max 3 Steigung haben Die L nge des horizontalen Abschnitts muss kurz gehalten werden und darf auf keinen Fall l nger als 3 m sein ohne T St ck darf nicht fter als 3 Mal die Richtung gewechselt werden bei Richtungswechsel gt 90 max 2 Rohrkr mmer mit einer horizontal gemessenen L nge von nicht ber 2 m verwenden Der Abgaskanal muss einen konstanten Querschnitt haben und das Auffangen von Ru gestatten SCHORNSTEINKOPF Vorrichtung am oberen Ende des Schornsteins die den Austritt der Verbrennungsprodukte in die Atmosph re erleichtert Technische Anforderungen den SCHORNSTEINKOPF gleicher Querschnitt wie der Schornstein der Nutzquerschnitt darf nicht kleiner als das Zweifache des Schornstein Innendurchmessers sein der Schornsteinkopf muss das Eindringen von Regen und Fremdk rpern verhindern und in jeder Witterung die Abf hrung der Verbrennungsprodukte sicherstellen er muss eine angemessene Verd nnung der Produkte garantieren und au erhalb des R ckflussbereichs positioniert sein er muss frei von mechanischen Saugvorrichtungen sein A Die direkte Abf hrung der Verbrennungsprodukte muss vom Dach erfolgen Die Abf hrung in geschlossene Bereiche auch unter freiem Himmel ist verboten 2 5 Positionsko
42. am Pelletzuf hrungskanal 3 6 Uberstrom Schutzvorrichtung 3 7 Uberdruckventil Wasserkreis 3 8 Abgasgebl se defekt 4 GEBRAUCH DES KESSELS 4 1 Vorwort 4 2 Beschreibung des Bedienpanels 4 3 Einschalten 4 3 1 Kontrolle vor Inbetriebnahme 4 3 2 Z ndvorgang 4 4 Betriebsphase 4 4 1 Wassertemperatur Sollwert ndern 4 4 2 Neustart aus STANDBY 4 4 3 Reinigung des Brenntopfes 4 4 4 Warmwasserbereitung mit Frischwassermodul 4 4 5 Warmwasserbereitung mit Warmwasserspeicher 4 4 6 Anlage mit Pufferspeicher Warmespeicher 4 5 Ausschalten 99 COLA 4 9 Men 4 6 1 Men 01 Uhrenthermostat einstellen 4 6 2 Men 02 Vom Benutzer vorgenommene Einstellungen 4 6 3 Men 03 Benutzerdefinierte Einstellungen 4 6 4 Men 04 Betriebszustand des Kessels 4 6 5 Men 05 Vom Installateur vorgenommene Einstellungen 4 7 Externer Thermostat Uhrenthermostat 4 8 AuBerbetriebnahme Ende der Heizperiode 5 REINIGUNG DES HEIZKESSELS 5 1 Reinigung Brenntopf Brenntopfhalter 5 2 Reinigung Aschebehalter 5 3 Reinigung Saugzuggeblase und Brennkammer 5 4 Reinigung des Luftmassenmessers 5 5 Reinigung Abgasstutzen Schornsteinrohr 5 6 Reinigung der Warmetauscher mit dem Turbulatorenr ttler 6 WARTUNG 6 1 Vorwort 6 2 Ausbau der Kesselverkleidung 6 3 Innere Kesselteile 6 4 Elektrische Bauteile 6 5 Serienm Bige Bauteile des Wasserkreises 7 FEHLERSUCHE 7 1 Verwaltung der Alarmmeldungen 8 ANH NGE 8 1 Informat
43. anomal a se indica en el panel de mandos con el mensaje AL 7 SEGUR TERMICA Si act a el termostato gt Deje enfriar la caldera al menos 45 minutos Rearme el termostato pulsando el bot n situado junto al interruptor de la caldera figura al lado previa extracci n de la protecci n T1 termostato temperatura de agua en c mara t rmica T2 termostato temperatura conducto alimentaci n de pellets gt Encienda la caldera normalmente Temperatura de actuaci n termostato dep sito de pellets gt 85 C Temperatura de actuaci n termostato camara t rmica gt 95 C 3 5 Seguridad contra el retorno de llama al conducto de alimentaci n de pellets El retorno de la llama se impide mediante Depresi n en la c mara de combusti n apartado 3 2 gt Forma en sif n del conducto de alimentaci n de pellets Termostato de seguridad del dep sito apartado 3 4 3 6 Dispositivo el ctrico de protecci n contra sobrecorrientes El equipo est protegido contra sobrecorrientes por uno o m s fusibles de 2 A instalados en la alimentaci n del interruptor general de la caldera situado en la parte posterior 3 7 Seguridad contra sobrepresiones en el circuito hidr ulico En caso de sobrepresi n del agua en la c mara P gt 3 bar la v lvula de seguridad montada en el sistema hidr ulico interior de la caldera se abre y descarga agua A Esta prohibido alterar los dispositivos de seguridad 3 8 Fallo del ventilador de extracci
44. completamente il pellet dal serbatoio scollegare l alimentazione elettrica pulire accuratamente e se necessario sostituire eventuali parti danneggiate da parte di personale qualificato proteggere la caldaia dalla polvere con idonea copertura sistemare in un luogo asciutto sicuro e riparato da agenti atmosferici 28 DOMUSFIRE C29 C35 C39 COLA 5 PULIZIA DELLA CALDAIA E importante procedere alla pulizia della caldaia per evitare cattiva combustione deposito di cenere ed incombusti nel braciere nonch minore efficienza termica La caldaia deve funzionare solo ed esclusivamente con porta fuoco e porta cenere chiuse Le guarnizioni delle porte devono essere controllate periodicamente per evitare infiltrazioni d aria in quanto devono garantire la tenuta in depressione della camera di combustione Le operazioni di pulizia ordinarie vengono normalmente effettuate dal cliente seguendo le indicazioni del manuale mentre le manutenzioni straordinarie almeno 1 all anno devono essere svolte dal Centro Assistenza Tecnico autorizzato Le operazioni di pulizia di tutte le parti vanno eseguite a caldaia completamente fredda ed A elettricamente scollegata Smaltire i rifiuti della pulizia secondo le norme locali vigenti E vietato mettere in funzione la caldaia priva dei rivestimenti esterni Evitare la formazione di fumo ed incombusti in fase di accensione e o durante il normale funzionamento Di seguito veng
45. d assistance d bitm tre T La s amorce pour faire Cette alarme se d clenche ee sa circuler l eau dans le circuit de RISQUE DE lorsque la temp rature de l eau temp rature de l eau en dessous Aa GEL descend en dessous d une de sianalecbar un Surveiller la temp rature de l eau certaine valeur message a l cran 9 pour viter qu elle ne descende en dessous de 0 lt Cette alarme se d clenche Les op rations de nettoyage CH ANCE lorsque la chaudi re a fonctionn entretien extraordinaire et de ENTRETIEN 5 Kar d SE E Avis d entretienextraordinaire r tablissement du fonctionnement erni re intervention d entretien normal doivent tre effectu es par un centre d assistance agr 97 DOMUSFIRE C29 C35 C39 COLA 8 ANNEXES INFORMATIONS RELATIVES AU MARQUAGE CE CE MARKING INFORMATION TUV K8552012T1 K8552012T2 K8552012S3 13 EN 303 5 2012 Type Chaudiere a granul s Heating Boiler Model DOMUSFIRE DOMUSFIRE DOMUSFIRE Mod le C29 C35 C39 EUM Granul s de bois Wood pellet UNI EN14961 2 classe A1 Puissance thermique introduct kW 29 0 64 344 64 38 3 6 4 Heating input Puissance thermique utile kW 274 5 78 32 4 5 78 34 9 5 78 Water heating output 94 45 90 14 94 18 90 14 91 32 90 14 Efficiency Consommation horarie Emissions CO 10 O2 m 2 e Emission CO at reference 10 O2
46. de 3 vers le haut la longueur du tron on ne doit pas d passer 3 m minimum le nombre de d voiements admis sans raccord en T ne doit pas tre sup rieur 3 en cas de d voiement gt 90 pr voir le montage de 2 coudes maximum d une allure horizontale ne d passant pas 2 m le conduit de raccordement doit avoir une section uniforme sur toute la longueur et permettre de r cup rer la suie SOUCHE DE CHEMIN E appel e aussi SORTIE DE TOIT l ment plac au sommet du conduit de fum e ou de chemin e sa partie ext rieure servant vacuer dans l atmosph re les produits de combustion Prescriptions techniques de la SOUCHE DE CHEMINEE elle doit avoir une section quivalente celle du conduit de fum e elle doit avoir une section utile non inf rieure au double de la section int rieure du conduit de fum e elle doit emp cher la p n tration de la pluie de la neige et ou d autres corps trangers dans le conduit de fum e et garantir en toutes conditions climatiques l vacuation des produits de combustions les fum es elle doit pouvoir assurer une dilution ad quate des produits et tre positionn e en dehors de la zone de reflux elle ne doit pas comporter de moyens m caniques d aspiration A L vacuation directe des produits de combustion doit tre pr vue en toiture et reste interdite vers des espaces clos m me a ciel ouvert 2 5 Contr le de la position du brasier et des
47. del brasero El reencendido se produce cuando la temperatura del agua alcanza i AE E E C A el valor de consigna SET programado pa RAFFRE 4 4 4 3 Limpieza del brasero Durante el funcionamiento normal en modo Trabajo a intervalos r programados mediante un par metro se activa el modo LIMPIEZA BRASERO durante el tiempo especificado 436 955 LI EPA Potencia ajustada bRASERU 148 DOMUSFIRE C29 C35 C39 COLA 4 4 4 Agua caliente sanitaria con intercambiador rapido Cuando hay una demanda de agua sanitaria en la pantalla aparece la indicaci n INTERC SANIT y se enciende el s mbolo del grifo Esta funci n se realiza solamente si la caldera est encendida y el agua de la c mara t rmica ha alcanzado una temperatura suficiente En los dem s casos el suministro no se produce 4 4 5 Agua caliente sanitaria con acumulador Esta configuraci n exige el uso de un termostato exterior o de una sonda de agua para medir la temperatura del agua sanitaria contenida en el acumulador Cuando la temperatura se hace inferior a la consigna se activa la producci n de agua sanitaria En la pantalla de la caldera aparece el mensaje ACUMUL SANIT y se enciende el s mbolo del grifo mientras se satisface la demanda Si la caldera est en modo ESPERA DEMANDA se enciende autom ticamente y se dispone en TRABAJO Cuando el agua de la c mara t rmica alcanza la temperatura de trabajo se activa el suministro de agua al acumula
48. der Kessel in einer robusten Verpackung verschlossen und nach Absprache mit den zustandigen Stellen den geltenden gesetzlichen Bestimmungen entsprechend entsorgt bzw bei Kauf eines neuen gleichartigen Ger ts an den H ndler zur ckgegeben werden Gem B Art 13 des gesetzesvertr Dekrets Nr 151 vom 25 Juli 2005 zur Umsetzung der Richtlinie 2002 96 EG vom 23 Februar 2003 ber Elektro und Elektronik Altger te Waste of Electrical and Electronic Equipment in Bezug auf MaBnahmen und Verfahren zur Vermeidung der Erzeugung von Elektro und Elektronikschrott bezeichnet auch als WEEE mit der die Wiederverwendung das Recycling und sonstige Formen der R ckgewinnung gef rdert werden sollen um die zu entsorgenden Mengen zu verringern und die T tigkeit der Personen die am Produktlebenszyklus teilnehmen zu optimieren Das Symbol der durchgekreuzten M lltonne auf dem Etikett des Ger ts bedeutet dass das Produkt am Ende seiner Nutzungsdauer vom Haushaltsm ll getrennt gesammelt werden muss 1 10 Anleitungen f r Eingriffsanforderungen und Ersatzteilbestellungen Zur Anforderung eines Eingriffs und oder f r Ersatzteilbestellungen wenden Sie sich bitte an Ihren H ndler den Gebietsimporteur oder an den n chstgelegenen Vertragskundendienst und geben Sie die folgenden Daten an Kesselmodell Seriennummer Kaufdatum Ersatzteilliste und Informationen ber die festgestellten Fehlfunktionen oder Betriebsst rungen ausgef hrt werden Vor
49. des hinterleuchteten Displays von min 0 bis max 100 eingestellt werden Set Temp Boiler Puffer Die Solltemperatur des Warmwasserspeichers des Heizwassers oder von beiden kann zwischen min 40 C bis max 80 C gew hlt werden Delta Boiler Puffer Mit dieser Option kann die Temperaturdifferenz zwischen dem Ab und anschlie enden Wiedereinschalten des Kessels von min 0 5 C bis max 20 C je nach Anforderungen des Kunden und oder Anlagenart eingestellt werden Pelletf llstand Wenn diese Option auf ON eingestellt ist kann die Signalisierung von Pelletmangel wie folgt gehandhabt werden Meldung auf dem Display PELLETS FEHLEN Ansteuerung eines zus tzlichen Pelletbeh lter f r die Nachf llung auf Anfrage lieferbar Mit der Einstellung OFF wird der eventuelle zus tzliche Beh lter deaktiviert und auf dem Display wird keine Anzeige eingeblendet Warmwasserbereitung aktivieren Mit dieser Option und der Ausr stung mit dem Zubeh r f r Warmwasserbereitung Pumpe W rmetauscher Ventil kann das Warmwasser vom Boiler oder W rmetauscher ber das vom Thermostat oder Str6mungswachter kommende Signal gesteuert werden 4 6 4 Men 04 Betriebszustand des Kessels Mit dieser Option kann der aktuelle Betriebszustand des Kessels aufgerufen und der Status der verschiedenen daran angeschlossenen Vorrichtungen angezeigt werden f r die berwachung stehen mehrere aufeinander folgende Seiten zur Verf gung 4 6 5 Men
50. e o operazioni per accedere al prodotto smontaggio mobili o pareti allestimento ponteggi o altro Responsabilit Il personale autorizzato dall azienda Produttrice interviene a titolo di assistenza tecnica del Cliente l Installatore resta comunque l unico responsabile dell installazione il quale deve rispettare le prescrizioni di legge attualmente vigenti e le indicazioni tecniche presenti nei manuali d uso e manutenzione a corredo del prodotto Le condizioni di Garanzia convenzionale sopraelencate sono le uniche offerte dalla Ditta COLA Srl nessuna terza parte autorizzata a modificare i termini della presente Garanzia n rilasciare altri verbali o documenti Diritti di legge La presente Garanzia si aggiunge e non pregiudica i diritti del Consumatore previsti dalla Direttiva 1999 44 CE e relativo Decreto legislativo Digs 6 09 2005 n 206 Cod Fisc P IVA e Iscr Reg Impr 02990180230 Capitale Sociale Euro 52 000 00 i v R E A VR 301021 Socio Unico Fax Amministrazione 045 6100317 Fax Commerciale 045 7639032 Fax Assistenza 045 7639030 Fax Logistica 045 6144048 gBuppo email info anselmocola com on line www colastufe com F COLA s r l Viale del Lavoro 7 9 37040 Arcole VR Italy Tel 045 7635780 045 6144043 direzione e coordinamento della Ferroli spa 2 DOMUSFIRE C29 C35 C39 COLA Istruzioni Convalida Primo Controllo gratuito Con la presente siamo a comunicarVi l aggiornamento del pr
51. e uso consentito Le caldaie a pellet funzionano esclusivamente con pellet pastiglie di varie essenze di legno conformi alla normativa DIN plus 51731 o UNI EN 14961 2 o O Norm M 7135 ovvero aventi le seguenti caratteristiche Potere calorico min 4 8 kWh kg 4180 kcal kg Densit 680 720 kg m3 Umidit max 10 del peso Diametro 6 40 5 mm Percentuale ceneri max 1 5 del peso Lunghezza min 6 mm max 30 mm Composizione 100 legno non trattato dell industria del legno o post consumo senza aggiunta di sostanze leganti e privo di corteccia conforme alle normative vigenti Imballo in sacchi realizzati in materiale ecocompatibile o biologicamente decomponibile o in carta Il serbatoio di contenimento del pellet si trova nella parte posteriore della caldaia Lo sportello di apertura e posizionato nella parte superiore e il caricamento avviene manualmente solo a caldaia spenta ponendo attenzione a non farlo fuoriuscire dal serbatoio L utilizzo di pellet con caratteristiche diverse rispetto a quello testato dal tecnico durante la 1 accensione implica una nuova taratura dei parametri di carico pellet della caldaia tale intervento escluso dalla garanzia Immagazzinare il pellet in luogo asciutto e privo di umidit Ai fini di un funzionamento regolare ed efficiente non possibile il caricamento manuale del pellet o A altri combustibili nel braciere Con il tempo nel serbatoio pellet si accumula della polvere che potrebb
52. eau chaude sanitaire l cran affiche ECHANG SANIT et la LED indiqu e par le robinet s allume La fonction sera lanc e uniquement si la chaudi re est allum e et si l eau de la chambre de combustion atteint une temp rature suffisante Dans les autres cas le service n est pas disponible 4 4 5 Eau chaude sanitaire avec ballon d accumulation Ce type d installation n cessite l utilisation d un thermostat ext rieur ou d une sonde eau pour mesurer la temp rature de l eau sanitaire du ballon Lorsque la temp rature descend sous la temp rature de CONSIGNE pr r gl e la fonction sanitaire s enclenche l cran de la chaudi re affiche BALLON SANIT et la LED indiqu e par le robinet s allume jusqu ce que la demande soit satisfaite Si la chaudi re est en phase de DEMANDE d ATTENTE elle s allume automatiquement et se met en mode FONCTIONNEMENT Lorsque l eau atteint la temp rature de service dans la chambre de combustion l eau arrive au ballon Lorsque la temp rature de CONSIGNE du ballon est atteinte la CHAUDI RE convertit la chaleur r siduelle au circuit de chauffage pendant 2 minutes environ puis s il n y a pas d autre demande se met en DEMANDE D ATTENTE ou en MODULATION en fonction de la configuration voir parag 4 6 4 Si la chaudi re est en mode TEINT elle ne s allume pas et le service n est pas disponible 4 4 6 Installation avec puffer accumulateur de chaleur Ce type d installation n cessite l utilisation d un
53. funzionamento segnala tramite un messaggio SCADENZA SERVICE la richiesta di manutenzione straordinaria non in garanzia da parte di personale qualificato il quale provvede ad una pulizia completa e al ripristino del messaggio A Eventuali urti o forzature possono danneggiare l estrattore fumi rendendolo rumoroso durante il funzionamento pertanto si consiglia di far eseguire tale operazione da personale qualificato 5 4 Pulizia debimetro All interno del tubo di aspirazione installato un debimetro misuratore del flusso d aria comburente il quale periodicamente ogni 3 4 mesi necessit di una pulizia interna con opportune attrezzature soffio d aria compressa o idonei pennelli 5 5 Pulizia raccordo fumi canna fumaria Il raccordo fumi deve essere pulito minimo una volta all anno o quando se ne presenti la necessit L operazione di pulizia prevede l aspirazione e la rimozione dei residui su tutti i tratti verticali e orizzontali nonch le curve dall apparecchio alla canna fumaria E consigliato pulire annualmente anche la canna fumaria per avere la garanzia di una corretta e sicura evacuazione dei fumi 5 6 Pulizia scambiatori con il dispositivo scuoti turbolatori La pulizia dei tubi passaggio fumi interni alla termo camera va eseguita almeno una volta ogni 2 3 giorni agendo ripetutamente sui due pomelli con movimento dal basso verso l alto e viceversa Eseguire l operazione a caldaia spenta e fred
54. gionales d partementales et communales en vigueur dans le pays d installation 2 9 2 Caract ristiques eau du circuit Les caract ristiques chimico physiques de l eau du circuit et d appoint sont importantes pour le fonctionnement et la dur e de la chaudi re lorsque l eau est de mauvaise qualit les d p ts calcaires s accumulent r duisent l change thermique et provoquent des ph nom nes de corrosion Il est conseill de v rifier la qualit de l eau et de proc der un traitement si les conditions ci apr s se pr sentent eau particuli rement calcaire gt 20 tr s grande quantit d eau d appoint ou remplissages successifs circuits particuli rement complexes et de grande dimension 2 9 3 Circuit sanitaire Pour raccorder la chaudi re une installation d eau chaude sanitaire il est conseill de s adresser un technicien comp tent afin d optimiser les raccordements hydrauliques et les performances du circuit sans compromettre le fonctionnement de l appareil Pour le raccordement du circuit sanitaire il est n cessaire de pr voir un des accessoires optionnels suivants une pompe sanitaire sur le collecteur de d part avec ses tubes de raccordement placer l int rieur de la chaudi re OU une pompe sanitaire changeur a plaques et tubes de raccordement a placer a l int rieur de la chaudi re o une vanne 3 voies installer l ext rieur de la chaudi re 78 DOMUSFIRE C29
55. heating chamber heating DHW circuit The antifreeze function is active only when the boiler is electrically powered The boiler must also be suitably separated from flammable or combustible materials by air spaces or the use of appropriate protective insulation floors and or ceiling coverings in flammable or heat sensitive material must be protected by panels of insulating material Make sure there are spaces at the sides and rear of the boiler necessary for servicing and cleaning the unit fume ducts and the flue Also make sure the pellet hopper is easily accessible for loading the fuel The minimum distances for maintenance and safety must comply with the following table A B BE i BOILER OPTIONAL BOILER SUPPLEMENTARY HOPPER 500 L L 500 mm C 500 mm D 1000 mm nl mon e 2 L 1450 mm P 700 mm 43 DOMUSFIRE C29 C35 C39 COLA Flue connection Inspection door on flue Wall air inlet min 100 cm T union with inspection cap The boiler is provided with 4 adjustable feet to facilitate positioning on not perfectly flat floors To adjust the height tilt the boiler and turn the feet as required 2 3 Air inlet The boiler must have the combustion air needed to ensure proper operation through external air inlets and specifically a wall air inlet of at least of 100 cm communicating with the outside and suitably prote
56. humos funciona a alta velocidad y en pantalla aparece la indicaci n LIMPIEZA FINAL Temperatura H20 Acumulador o Dep sito inercia Al final de la operaci n en pantalla aparece la indicaci n APAGADO Durante la fase de apagado no se puede volver encender la 2E sc caldera hasta que la temperatura de los humos permanece por debajo de un valor prefijado durante el tiempo programado En pantalla aparece la indicaci n ESPERA REFRIGER APABAdO Ventana de di logo 149 DOMUSFIRE C29 C35 C39 4 18 Menu Pulsando la tecla SET se accede al men que permite hacer los ajustes por los cuales se regir el control electr nico COLA En la tabla siguiente se describe la estructura del men con los ajustes que puede realizar el usuario Elemento men Posici n nivel 2 Pens Posici n nivel 3 Nombre par metro Unidad see Doe Habilita crono M 1 1 01 Habilita crono ON OFF M 1 2 01 Crono d a M 1 2 02 Start 1 d a M1 2 Program d a M 1 2 03 Stop 1 d a M 1 2 04 Start 2 d a M 1 2 05 Stop 2 d a M 1 3 01 Crono semana ON OFF M 1 3 02 Start Prog 1 M 1 3 03 Stop Prog 1 M 1 3 04 Lunes Prog 1 M 1 3 05 Martes Prog 1 M 1 3 06 Mi rcoles Prog 1 M 1 3 07 Jueves Prog 1 M 1 3 08 Viernes Prog 1 M 1 3 09 S bado prog 1 M 1 3 10 Domingo Pr
57. impianto senza compromettere la funzionalit dell apparecchio Per il collegamento al circuito sanitario necessario richiedere uno dei seguent i optional pompa sanitario sul collettore di mandata con i relativi tubi di collegamento da collocare internamente alla caldaia oppure pompa sanitario scambiatore a piastre e tubi di collegamento da collocare internamente alla caldaia oppure una valvola a 3 vie da installare esternamente alla caldaia 16 DOMUSFIRE C29 C35 C39 COLA Completato il collegamento sanitario necessario entrare nel menu tecnico del controllo selezionare la tipologia del circuito ogni specifica funzione sanitario impostata SCAMBIATORE SANITARIO BOILER PUFFER o BOILER SANITARIO compare sul display al momento della commutazione riscaldamento sanitario con uno dei messaggi sotto riportati rimane fino al termine della richiesta di acqua calda sanitaria da termostato flusso stato 2 9 4 Schemi idraulici Caldaia Schema idraulico Caldaia a pellet con pompa sanitario_07 2012 Caldaia a pellet OUT Control IN system I Termostato T gt 85 C A MANDATA Riscaldamento maschio 1 B RITORNO Riscaldamento maschio 1 C MANDATA Sanltarlo maschio 3 4 Termocamera Pellet D RITORND Sanltarlo maschlo 3 4 E Alinentazione acquedotto Fl 2 F Scorlco acqua In sovrapres Fl 2 LEGENDA 1 Rubinetto dl scarico 0 Flussostoto e Sensore di pressione manometro 8 Scamblato
58. in this manual Avoid taking the load in areas where it could be a danger if dropped During transport and storage avoid exposure to rain or persistent humidity The boiler must only be moved in a vertical position by forklift resting on the base A Use suitable equipment to remove the boards or wooden parts of the boiler packing Disposal or recycling of the packing must be done by the end user complying with local regulations on waste and keeping it out of the reach of children or disabled persons 2 2 Place of installation positioning and fire prevention safety After preparing the water and electrical connections by a qualified technician open the packing remove the boiler from pallet and place it in the desired location making sure it complies with the requirements in this manual Set the boiler down on the floor carefully without bumping and position it in the required place Make sure the floor can take its weight otherwise see a specialised technician After removing the protective packing be careful not to damage the mechanical and electrical parts by knocking or splashing with water The place of installation must be sufficiently ventilated to allow the removal of any combustion smoke leaks The unit is suitable for operation in technical environments with min temperature not below 0 C it comes complete with an antifreeze function that activates the heating pump for system water temperatures below 6 C safeguarding
59. inferior a 45 respecto al Tubo de eje ld humos estar suficientemente aislada de materiales inflamables mediante una C mara c mara de aire o aislante WESSEN tener secci n interior preferiblemente circular constante libre e Toma de aire independiente exterior en lo posible tener una c mara inspeccionable para la recolecci n de u Ar materiales s lidos Distancia min Sen 2m y posibles condensados debajo de la embocadura del tubo de humos TUBO DE SALIDA DE HUMOS conducto o elemento de conexi n entre el equipo y la chimenea para la evacuaci n de los productos de combusti n Requisitos t cnicos del TUBO DE HUMOS no debe atravesar locales donde no se permita instalar aparatos de combusti n est prohibido realizarlo con tubos met licos flexibles o de fibrocemento est prohibido utilizar elementos en contrapendiente los tramos horizontales deben tener una pendiente m nima de 3 hacia arriba la longitud del tramo horizontal debe ser lo menor posible y nunca superior a 3 m el n mero de cambios de direcci n sin el empalme en T no debe ser superior a tres para un cambio de direcci n de m s de 90 usar como maximo dos codos cuya longitud en proyecci n horizontal no sea superior a 2 m el tubo de humos debe tener secci n constante y permitir la extracci n del holl n SOMBRERETE dispositivo montado en la cima de la chimenea que sirve para descargar a la atm sfera los p
60. informa de la falta de pellets mediante mensaje FALTAN PELLETS en el panel utilizaci n de un dep sito auxiliar de recarga de pellets opcional Si se selecciona OFF no aparece ning n mensaje ni se utiliza el posible dep sito auxiliar Activar ACS Cuando se activa esta funci n si est instalado el accesorio para agua caliente sanitaria bomba intercambiador y v lvula se activa el suministro de agua sanitaria desde el acumulador o el intercambiador mediante la se al enviada por un termostato o flujostato 152 DOMUSFIRE C29 C35 C39 COLA 4 6 4 Menu 04 Estado caldera Esta selecci n permite visualizar el estado actual de la caldera de los dispositivos conectados a ella El men consta de varias p ginas sucesivas 4 6 5 Men 05 Ajustes del instalador Este men est reservado a los t cnicos autorizados del centro de asistencia de COLA S r l La modificaci n de los par metros t cnicos en el men 05 debe ser efectuada por personal autorizado A Las modificaciones por parte de otras personas pueden causar graves da os que eximen de toda responsabilidad a COLA S r l 4 7 Termostato cronotermostato externo Si se desea utilizar un termostato externo acudir a un t cnico autorizado para que realice la instalaci n de acuerdo con las siguientes instrucciones Apague el equipo con el interruptor general situado en la parte posterior y desconecte el cable de la corriente el ctrica Desmonte el pa
61. jedem Eingriff ist immer die Stromversorgung zu unterbrechen Der Kessel muss kalt sein AusschlieBlich Original Ersatzteile benutzen N Alle Eingriffe an den Komponenten m ssen von autorisiertem und oder qualifiziertem Personal 2 TRANSPORT UND INSTALLATION 2 1 Liefer Transport und Lagerbedingungen Am Ende des Produktionszyklus und nach Bestehen der funktionellen Abnahme an der Montagelinie wird der in eine Nylon Schutzfolie geh llte Kessel auf einer Palette Lattenkiste ausgeliefert Der Kessel samt Verpackung kann mit einem Gabelstapler angehoben werden indem die ausreichend langen Gabeln an den passenden Stellen in der Holzpalette eingef hrt werden Es muss unbedingt sichergestellt werden dass die Hebe und Transportmittel f r das am Typenschild und im vorliegenden Handbuch angegebene Kesselgewicht geeignet sind Auf keinen Fall die Last in Bereichen bef rdern in denen das Herunterfallen eine Gefahr darstellen k nnte 105 DOMUSFIRE C29 C35 C39 COLA W hrend Transport und Lagerung darf der Kessel keinem Regen oder andauernder Feuchtigkeit ausgesetzt werden Der Kessel darf nur stehend mit Wagen am Unterbau bef rdert werden A Die Latten oder Holzteile der Kesselverpackung m ssen mit geeignetem Werkzeug entfernt werden Die Verpackung muss vom Endkunden gem den geltenden rtlichen Abfallbestimmungen entsorgt oder recycelt werden und darf nicht in Reichweite von Kindern oder behinderten Personen gelangen
62. la falta de respeto o aplicaci n de las indicaciones indicadas en el presente manual 4 DOMUSFIRE C29 C35 C39 1 AVVERTENZE GENERALI 1 1 Introduzione 1 2 Come utilizzare il manuale 1 3 Norme di sicurezza 1 4 Descrizione tecnica 1 5 Combustibile e uso consentito 1 6 Accessori in dotazione 1 7 Riferimenti normativi 1 8 Targa di identificazione 1 9 Messa fuori servizio della caldaia 1 10 Istruzioni per richiesta di intervento e 2 TRASPORTO ED INSTALLAZIONE 2 1 Condizioni di fornitura trasporto e immagazzinamento 2 2 Luogo d installazione posizionamento e sicurezza antincendio 2 3 Presa aria 2 4 Scarico fumi di combustione 2 4 1 Tipologie di installazione 2 5 Controllo posizione bracere e turbolatori 2 6 Collegamento elettrico 2 7 Schema elettrico 2 8 Schema elettrico per impianto a zone 2 9 Collegamenti idraulici 2 9 1 Carico acqua impianto 2 9 2 Caratteristiche acqua d impianto 2 9 3 Impianto sanitario 2 9 4 Schemi idraulici Caldaia 2 10 Pronto intervento 3 SICUREZZE DELLA CALDAIA 3 1 Distanza sicurezza mat infiammabili 3 2 Sicurezza scarico fumi 3 3 Sicurezza sovrapressione in camera di combustione 3 4 Surriscaldamento termostati 3 5 Sicurezza contro il ritorno di fiamma sul canale alimentazione pellet 3 6 Dispositivo elettrico di protezione della sovracorrente ricambi 3 7 Sicurezza sovrapressione circuito idraulico 3 8 Guasto ventilatore estrazione fumi 4 USO DELLA CALDAIA 4 1 P
63. minimum of 0 5 C to a maximum of 20 C according to the needs of the customer and or type of system Pellet level With the selection set to ON the no pellets signal can be managed with a message on the panel PELLETS management of a supplementary pellet hopper available on request With the selection OFF the possible supplementary hopper is disabled and no message appears on the panel DHW on With this selection and prearrangement of the DHW accessory pump exchanger valve it is possible to manage DHW from the storage tank or heat exchanger through the signal from the thermostat or flow switch 4 6 4 Menu 04 boiler status With this selection it is possible to display the instantaneous boiler status giving the operating status of the various devices connected to it various pages placed in succession are available for monitoring 4 6 5 Menu 05 Installer adjustments This selection is reserved for the COLA service centre authorised technician personnel any changes made at random can cause serious damage for which COLA declines any Modification of the technical parameters of menu 05 must be done by authorised and competent A liability 58 DOMUSFIRE C29 C35 C39 4 7 Thermostat external chronothermostat To use an external thermostat contact an authorised technician and for installation proceed as follows turn off the power by the main switch on the back and unplug the power cable remove the side p
64. monter sur le circuit pendant l installation de la chaudi re ne sont pas fournies avec l appareil 10 Soupape de s ret P max 6 bars 79 DOMUSFIRE C29 C35 C39 COLA Sch ma hydraulique de la chaudi re granul s avec changeur a plaques pour ECS_07 2012 Chaudi re granul s Thermostat T gt D PART Chauffage m le 1 lectroniquel IN ide 4 commande DEPART ECS male 1 2 Chambre de RETOUR ECS m le 1 combustion pour granul s Alimentation r seau eau de ville F1 2 Evacuation eau en surpression F1 2 F 1 2 LEGENDE Robinet de vidange a Fluxostat 2 Capteur de pression manom tre 2 changeur plaques pour ECS 3 Circulateur 3 Soupapes d quilibrage circuit S Vase d expansion membrane a Soupape thermostatique automatique 6 RobinetVanne d arr t Capteur de s curit gt 85 C e Clapet anti retour Capteur de temp rature de l eau 8 vent bord chambre de combustion circuit Capteur de pression du circuit 9 Soupape de s ret P max 3 bars PEH soupapes monter sur le circuit pendant EE l installation de la chaudi re ne sont pas 0 Soupape de s ret P max 6 bars fournies avec l appareil 2 10 Premi re intervention Il est toujours conseill d installer des quipements anti incendie appropri s En cas d incendie D brancher imm diatement le cordon d alimentation de la chaudi re Eteind
65. poussi res 1396 O5 Emission dust at reference 1396 O Totale des missions de particules PPBT 139605 Total dust emission PPBT at ref 13 3 Temp rature max de l eau reglable Set max temp Pression max acqua d utilisation Max working pressure Heating chambre capacity en EH Pellet stove capacity Chaudi re class rif EN303 5 2012 Boiler class rif EN303 5 2012 E Perte de charge sur le cot AT 10K 386 9 521 7 624 7 Water resistance AT 10K Perte de charge sur le cot AT 20K DANS IE Miss 134 3 62 6 148 6 62 6 159 5 62 6 Fume outlet temperature 17 6 6 9 19 66 12 69 3 3 3 3 spa ja 2 3 3 3 w w o o D bit gaz de combustion gis 141 54 163 54 182 54 Flue gas flow Tirage fum e min max Pa 1 Draught min max islas BE Tuyau d evacuation des fum es Fume outlet pipe Alimentazion lectrique 230V 50Hz 6A Electrical power Alumage Start 476 Stand by4 P nen 160 P rid 153 Rated input power Dimensions HxLxP 1300 x 700 x 1300 x 700 x 1300 x 700 x 698 698 698 ICAO Dimensions HxLxP Poids de la chaudi re Weight puissance nominale et de faible puissance Nominal output and Reduced output La consommation de granul s peut varier selon le type de pellet utilis Pellet consumption can vary according to the type of pellets used 100 70 DOMUSFIRE C29 C35 C39 COLA Dimensions hors tout chau
66. prog 1 M 1 3 10 Sunday Prog 1 M 1 3 11 Start Prog 2 M 1 3 12 Stop Prog 2 M 1 3 13 Monday Prog 2 M 1 3 14 Tuesday Prog 2 M 1 3 15 Wednesday Prog 2 M 1 3 16 Thursday Prog 2 M 1 3 17 Friday Prog 2 M 1 3 18 Saturday prog 2 M1 3 Bee 1 3 19 Sunday Prog 2 M 1 3 20 Start Prog 3 M 1 3 21 Stop Prog 3 M 1 3 22 Monday Prog 3 M 1 3 23 Tuesday Prog 3 M 1 3 24 Wednesday Prog 3 M 1 3 25 Thursday Prog 3 M 1 3 26 Friday Prog 3 M 1 3 27 Saturday prog 3 M 1 3 28 Sunday Prog 3 M 1 3 29 Start Prog 4 M 1 3 30 Stop Prog 4 M 1 3 31 Monday Prog 4 M 1 3 32 Tuesday Prog 4 M 1 3 33 Wednesday Prog 4 M 1 3 34 Thursday Prog 4 M 1 3 35 Friday Prog 4 M 1 3 36 Saturday Prog 4 M 1 3 37 Sunday Prog 4 M 4 2 01 Week End Chrono ON OFF Week End M 4 2 02 Start 1 Week End M1 4 Program M 4 2 03 Stop 1 Week End M 4 2 04 Start 2 Week End M 4 2 05 Stop 2 Week End M 2 1 Set Clock M 2 2 Standby mode ON OFF Menu 02 User M 2 3 Initial load ON OFF adjustments M 2 4 Pellet type Pellet adjustment 9 9 M 2 5 we Pellet adjustment ON OFF M 3 1 Language M 3 3 Buzzer mode ON OFF M 3 4 Lighting 0 100 Set Temp Menu 03 User M 3 6 Storage tank 40 80 settings Puffer Storage tank Puffer Delta 0 5 20 M 3 8 Pellet level ON OFF M 3 9 DHW on ON OFF Menu Eege menu for technician status Menu 05 Installer menu for technician adjustments 56 DOMUSFIRE C29 C35 C39 4 6 1 Menu 01 Chrono setting Allows all chronothermostat functions to be enabled disabled
67. programmierten Funktionen des Uhrenthermostats aktiviert deaktiviert und eingestellt werden Es k nnen zwei Betriebsphasen eingestellt werden die von den gem nachstehender Tabelle eingestellten Uhrzeiten begrenzt werden Die Einstellung OFF bedeutet dass die Uhr den Befehl ignorieren soll Auswahl Bedeutung START1 Aktivierungsuhrzeit Uhrzeit OFF STOP1 Deaktivierungsuhrzeit Uhrzeit OFF START2 Aktivierungsuhrzeit Uhrzeit OFF STOP2 Deaktivierungsuhrzeit Uhrzeit OFF Bei Offnen des Untermen s PROGRAM WOCHE k nnen die w chentlich programmierten Funktionen des Uhrenthermostats aktiviert deaktiviert und eingestellt werden Das Wochenprogramm verf gt ber 4 unabh ngige Programme deren Endeffekt aus der Kombination der 4 Programmierungen besteht Das Wochenprogramm kann aktiviert oder deaktiviert werden Durch Eingabe von OFF in das Feld mit den Stunden wird der entsprechende Befehl ignoriert durchgef hrt werden Darauf achten dass sich die Aktivierungs und oder Deaktivierungszeiten nicht am selben Tag in verschiedenen Programmen berlagern q Die Programmierung muss mit gr ter Sorgfalt Bei ffnen des Untermen s PROGRAM WOCHENENDE k nnen die Funktionen des Uhrenthermostats am Wochenende aktiviert deaktiviert und eingestellt werden Wochenende Samstag Sonntag Die Programmierung WOCHENENDE nur nach Deaktivierung der Wochenprogrammierung aktivieren Um ein
68. que est n dentro de la c mara Tambi n es importante limpiar el extractor de humos situado detr s del colector inferior de humos al cual se accede a trav s del registro de inspecci n que est detr s del cenicero Cada 3 4 meses limpie con un cepillo las paredes internas de la c mara de combusti n y del colector superior de humos Sustituya las paredes de vermiculita cuando corresponda ya que se consideran material de desgaste Cada 1800 horas de funcionamiento la caldera activa el mensaje LLAMAR SERVICE para indicar que se debe contactar con el centro de asistencia autorizado para realizar el mantenimiento extraordinario no cubierto por la garant a que incluye una limpieza completa y la anulaci n de dicho mensaje A Los golpes o forzamientos pueden da ar el extractor y causar un funcionamiento ruidoso encargue esta operaci n a personal cualificado 5 4 Limpieza del deb metro Dentro del tubo de aspiraci n hay un deb metro medidor del flujo de aire comburente que se debe limpiar por dentro cada 3 4 meses con un medio adecuado soplo de aire comprimido o escobilla 5 5 Limpieza del tubo de humos chimenea El tubo de humos se debe limpiar como m nimo una vez al a o y siempre que sea necesario La limpieza consiste en la aspiraci n y extracci n de residuos de todos los tramos verticales horizontales y curvos desde el equipo hasta la chimenea Tambi n se aconseja limpiar una vez al a o la chimenea para garan
69. supera el valor de consigna Carga inicial Esta funci n activa el motorreductor con la caldera apagada o fr a para realizar una precarga de pellets durante 90 segundos Se activa con la tecla P1 y se interrumpe con la tecla P4 Tipo de pellet Con esta funci n activada mediante las teclas P1 y P2 se aumenta o reduce la carga de pellets para optimizar el consumo y la combusti n en funci n del tipo de pellet utilizado Carga inicial sinf n 2 Esta funci n activa el motorreductor del dep sito auxiliar para que haga la precarga programada Se activa con la tecla P1 y se interrumpe con la tecla P4 4 6 3 Menu 03 Ajustes de usuario Este men da acceso a las siguientes configuraciones Idioma Permite seleccionar el idioma en que aparecer n las informaciones en pantalla entre los siguientes ITALIANO FRANCES INGLES ALEMAN Y ESPANOL Avis ac stico Permite activar o desactivar la se alizaci n ac stica de la caldera Luminosidad Permite ajustar la intensidad de la pantalla retroiluminada entre O y 100 Set Temp Acum D Inercia Permite ajustar la temperatura de consigna del acumulador de agua sanitaria de la calefacci n o de ambos entre 40 y 80 Delta Acumul D Inercia Permite establecer la diferencia de temperatura entre el apagado de la caldera y el pr ximo encendido entre 0 5 C y 20 seg n las exigencias del usuario o del tipo de sistema Nivel pellets Si se selecciona ON el sistema
70. surchauffer durant le fonctionnement Avant de proc der aux op rations d entretien d brancher la chaudi re et attendre qu elle ait refroidi Garantir une temp rature ambiante comprise entre 0 C et 35 C dans le local ou se trouve la chaudi re et s assurer que le taux d humidit n est pas trop lev par ex en cas de linge tendu pour s cher est absolument interdit de manipuler des substances facilement inflammables ou explosives proximit de la chaudi re quand elle est allum e l est interdit de modifier les dispositifs de s curit ou de r glage sans l autorisation du constructeur 68 DOMUSFIRE C29 C35 C39 COLA Toute modification ou adaptation non pr vue et ou tout remplacement non autoris de pi ces non originales de la chaudi re peut repr senter un danger pour les personnes et d gage le constructeur de toute responsabilit civile et p nale N utiliser que des pi ces de rechange d origine pr conis es par le constructeur Encas de dysfonctionnement il ne sera possible de rallumer la chaudi re qu apr s avoir r solu le probl me ne jamais d sactiver les syst mes de s curit Encas d incendie arr ter le chauffage d brancher l appareil et chercher teindre les flammes l aide de syst mes appropri s et ou faire appel aux Pompiers Nettoyer r guli rement le foyer chaque allumage ou chargement de granul s A Eviter la formation de fum e et r sidus non br
71. tre utilis e comme garage ni pour le stockage de mat riau combustible ou encore pour une activit entra nant un risque d incendie Le raccordement d aspiration ou la prise d air de la chaudi re se trouve l arri re et a une section circulaire de 60 mm de diam tre 2 4 vacuation des fum es de combustion Les fum es peuvent tre vacu es par un conduit de fum e conforme aux normes en vigueur aux consignes et ou dispositions locales normes nationales et europ ennes Utiliser imp rativement des tuyaux ou conduits et raccords certifi s avec des joints ad quats qui garantissent l tanch it L usage de conduits m talliques flexibles ou en fibrociment est interdit En cas d incendie teindre la chaudi re la d brancher et faire appel aux Pompiers viter de r p ter les tentatives d extinction 4 ll est recommand l installateur de v rifier l efficacit et l tat de la chemin e ainsi que la conformit 75 DOMUSFIRE C29 C35 C39 COLA 2 4 1 Typologies des installations Voici quelques d finitions et r gles d installation d un conduit de fum e selon la norme italienne UNI10683 CONDUIT DE CHEMIN E conduit vertical destin collecter et vacuer une certaine hauteur du sol les produits de combustion provenant d un seul appareil et dans les cas autoris s de plusieurs appareils m m 1 A gt Prescriptions techniques du CONDUIT DE CHEMINEE
72. unbeabsichtigtes Ein und Abschalten zu vermeiden A jeweils immer nur ein Programm aktivieren Das Tagesprogramm deaktivieren wenn das Wochenprogramm verwendet werden soll mit dieser Einstellung empfiehlt es sich das Wochenendprogramm Zu deaktivieren 120 T l iS 0 FRE GAbE CHRONO nai pe SEARE PROB 4 36 11 1 03 SEP DOMUSFIRE C29 C35 C39 COLA 4 6 2 Men 02 Vom Benutzer vorgenommene Einstellungen Mit diesem Men k nnen folgende Einstellungen vorgenommen werden Uhr einstellen Bevor der Kessel in Betrieb genommen wird m ssen Uhrzeit und Datum eingestellt werden damit die Programmierung des Uhrenthermostats m glich ist Die elektronische Regelung ist mit einer 3 Volt Lithiumbatterie Typ CR2032 ausgestattet dank der die interne Uhr eine Autonomie von ber 4 5 Jahren hat falls die Uhr bei ausgeschaltetem Kessel die Uhrzeit nicht gespeichert halt oder wenn bei Wiedereinschalten eine Reihe von Nullen angezeigt wird muss die Batterie vom Kundendienst ausgewechselt werden Standbybetrieb Bei Aktivierung dieser Funktion wird der Kessel automatisch abgeschaltet nachdem die Wassertemperatur f r eine vorgegebene Zeit Uber dem Sollwert geblieben ist Daraufhin kann der Kessel erst dann wieder automatisch eingeschaltet werden wenn die Wassertemperatur unter den in der Parametertabelle angegebenen Wert sinkt Voreinstellung 2 C M
73. werden kann oder mit einem direkten Anschluss nach au en durch ein geeignetes max 1 5 langes Rohr mit einem Innendurchmesser von 60 mm und geeignetem Schutz am Ende oder Uber einen Raum neben dem Aufstellungsraum sofern der Luftstrom ungehindert ber bleibende die oben genannten Anforderungen erf llende Offnungen nach au en erfolgt Aufgrund der durch m glicherweise vorhandene andere Ger te oder Saugzuggebl se herbeigef hrte Zugwirkung darf der Nachbarraum keinen Unterdruck im Vergleich zu au en aufweisen Der Nachbarraum darf nicht als Garage oder Brennstofflager dienen und darf vor allem nicht f r feuergef hrliche T tigkeiten genutzt werden Der Ansauganschluss bzw der Lufteinlass des Kessels befindet sich an der R ckseite und hat einen runden Querschnitt mit einem Durchmesser von 60 mm 2 4 Abgasf hrung Die Abgase m ssen durch den vorschriftsm igen Anschluss an ein Schornsteinrohr abgef hrt werden Die Funktionst chtigkeit und der einwandfreie Zustand des Schornsteinrohrs sowie dessen Konformit t A mit den rtlichen Regeln und oder Bestimmungen nationalen und europ ischen Normen sind vom nstallateur unbedingt zu pr fen Es d rfen nur zertifizierte Rohre und Anschl sse mit angemessenen Dichtungen verwendet werden Die Verwendung von Metallschl uchen oder Rohren aus Asbestzement ist verboten Im Brandfall den Kessel abschalten die Spannungszufuhr trennen und sofort die Feuerwehr rufen ohne weiter
74. 07 0 040 0 009 0 040 Emission CO at reference 1096 O2 Emissi CnH 110 ape 6 7 18 8 URN 6 6 18 8 6 7 18 8 146 7 116 4 147 1 116 4 130 2 116 4 24 1 9 5 0 004 0 029 4 9 13 78 106 8 84 6 17 6 6 9 19 66 12 69 mg m m 3 2 a ES D ES i mg m m 3 3 z o x a a i 3 8 3 amp o Emissione polveri al 10 O mg m 23 6 9 5 24 5 9 5 m 3 5 i 3 2 m e B 8 amp N 0 005 0 029 0 006 0 029 m 3 o o o o o 5 de 3 DN e m mim a 213 EE Q o glia 2 2 215 els a 3 013 SN H d sia Je R N 4 8 13 78 4 9 13 78 3 i 3 a 8 3 M Co o Emissione NOx al 13 O Emission NOx at reference 13 O gt Emissione polveri al 13 O 107 84 6 94 7 84 6 17 2 6 9 17 8 6 9 mim AE DIE 5 ays SE 519 5 2 5 2 0 Why ols A o m w o N 19 86 12 69 9 Total dust emission PPBT at ref 13 O STE ETE El STR E 8 gt Blo 3 8 5 Ble 213 8 ale gla js SIS SIS ln 21 ala ala 313 5 alo cla 2 als 2 Eu L t SIS jz 3 als s 8 S12 olo 216 3 SV g als a al alg Sla S 8 als 9 D c i 2 S g IS e z D 5 S 8 25 o a N 2 I N S 5 D 2 S Co o 3
75. 6 12 69 Total dust emission PPBT at ref 13 O i 209 12 Temperatura max acqua impostabile Set max temp Pressione max acqua di esercizio Max working pressure Capacit acqua caldaia Heating chambre capacity Capacit serbatoio pellet Pellet stove capacity Classe della caldaia rif EN303 5_2012 5 Boiler class rif EN303 5_2012 Perdite di carico lato acqua AT 10K 386 9 5217 6247 Water resistance AT 10K d Perdite di carico lato acqua AT 20K 96 73 130 4 156 2 Water resistance AT 20K i d iti ita fumi ume outlet temperature Portata dei fumi Ga e me Pur gas flow Tiraggio canna fumaria min max Pa T i Diametro tubo scarico fumi 100 Fume outlet pipe Alimentazione elettrica 230V 50Hz 6A Electrical power Assorbi to elettri Accensione Start 476 Stand by 4 P nom 160 P rid 153 ated input power senden 4 er HELEN 1300 700 698 WS 1300x700x698 1300x700x698 imensions xLx alla Potenza nominale Potenza ridotta Nominal output and Reduced output consumo di pellet variare dal tipo di pellet utilizzato Pellet consumption can vary according to the type of pellets used COLA s r l Viale del Lavoro 7 9 37040 Arcole VR Italy Tel 045 7635780 045 6144043 Cod Fisc PIVA e Iscr Reg Impr 02990180230 Capitale Sociale Euro 52 000 00 i v R E A VR 301021 Socio Unico o Fax Amministrazione 045 6100317 Fax Commerciale 045 7639032
76. 6 ERAbAJOJ Potencia ajustada a 3 de combustible Antes de cargar pellets cerci rese de que la caldera est apagada La tapa del dep sito de pellets debe estar siempre cerrada brala solamente para hacer la carga Guarde los sacos de pellets como m nimo a 1 5 m de la caldera i Se recomienda controlar el nivel de pellets en el dep sito para evitar que la llama se apague por falta 4 4 1 Modificaci n de la consigna de temperatura del agua Para modificar la temperatura del agua seleccione CAMBIAR SET AGUA con la tecla P3 Pulse luego las teclas P1 y P2 en pantalla aparece la consigna SET actual de temperatura SEE od Pr Cuando la temperatura del agua alcanza el punto de consigna o la temperatura de los humos llega al valor m ximo programado la potencia se reduce autom ticamente al m nimo en estado de MODULACI N Cuando la temperatura de los humos alcanza el valor m ximo programado en pantalla aparece el mensaje MODULA F y la caldera activa la modulaci n de la llama sin intervenci n del usuario Si la temperatura supera los 280 aparece la alarma AL3 ALTA TMP HUMOS y la caldera activa el procedimiento de apagado 4 4 2 Reencendido desde STAND BY En el modo STAND BY la caldera est controlada por el termostato de ambiente o el dep sito de inercia Tras el apagado la caldera inicia la operaci n de enfriamiento activando el extractor de humos a la velocidad programada para la limpieza
77. AR Se Pelee FALTAN brasero ellets debe asentarse T004 otra operaci n We PELLETS Ge n a restablecimiento debe ser pellets 9 efectuada por un centro de asistencia autorizado El termostato de seguridad ha 1 1 Senala que actuado desolado sobrecalentamiento at m de seguridad del superior al l mite espeeiticddo Rearmar con el bot n SEGUR seg para el sobrecalentamiento de la conducto del sinfin G ss 22 correspondiente el termostato TERMICA parte inferior del dep sito y ha El sistema se para que ha detectado el bloqueado el funcionamiento del motorredu tar sobrecalentamiento 159 DOMUSFIRE C29 C35 C39 COLA Indicacion Anomalia Causas posibles Soluci n La c mara de combusti n est Controlar la limpieza del tubo de sucia humos y de la c mara de combusti n AL En fase de trabajo la caldera El conducto de humos est Comprobar el cierre herm tico de la 8 detecta una presi n inferior al atascado puerta FALTA l mite de calibraci n del La puerta de la c mara est Comprobar el cierre de las v lvulas DEPRES vacuostato abierta antiexplosi n El sistema se para Las v lvulas antiexplosi n Toda otra operaci n de restable est n abiertas atascadas cimiento debe ser efectuada por un El vacuostato est averiado centro de asistencia auto
78. Accedendo al menu possibile ottenere i vari tipi di visualizzazione ed effettuare le impostazioni disponibili a seconda del livello di accesso 20 DOMUSFIRE C29 C35 C39 COLA x Di seguito riportata la tabella dei comandi e dei relativi messaggi visualizzati in fase di programmazione o impostazione dei parametri operativi pulsante display superiore SET Incrementa il valore della temperatura del termostato acqua e TEMPERATURA di quello ambiente Parametro selezionato parametro PROGRAMMAZIONE Incrementa il parameto selezionato Visualizza la temperature us meme S SET Decrementa il valore della temperatura del termostato acqua SET TEMPERATURA e di quello ambiente Hy aria Decremento Parametro Valore A A 1 e temperatura PROGRAMMAZIONE Decremento del parametro selezionato ER parametro LAVORO Visualizza lo stato operative della stufa Pressione nel ventola circuito acqua fumi Accede al SET della temperatura al menu dei parametri utente e tecnico con successive pressioni Premuto per 2 secondi accende o spegne la stufa se e spenta Visualizza lo accesa rispettivamente stato raggiunto SET parametro N 4 prota Sblocca la stufa e la riporta nello stato spento OFF PROGRAMMAZIONE Decrementa la potenza o il valore della Temperatura termostato acqua del boiler sanitario se abilitato Temperatura Livello potenza SET sanitario
79. C35 C39 COLA Le raccordement du circuit sanitaire termin acc der au menu technique du contr le et s lectionner le type de circuit chaque fonction sanitaire sp cifique pr s lectionn e ECHANGEUR SANITAIRE BALLON PUFFER ou BALLON SANITAIRE s affiche l cran au moment de la commutation chauffage sanitaire accompagn d un des messages ci dessous et reste affich jusqu la fin du besoin d ECS signal par le thermostat ou le d bitm tre 1436 pc 565 SAntE ECHANBEUR 2 9 4 Sch mas hydrauliques de la chaudi re Sch ma hydraulique de la chaudi re a granul s avec pompe Chaudi re a granul s Thermostat T gt 85 C lout Electronique IN de ommande DEPART Chauffage male 1 1 RETOUR Chauffage m le 1 D PART ECS m le 3 4 Chambre de combustion pour granul s RETOUR ECS m le 3 4 Alimentation r seau eau de ville F1 2 Evacuation eau en surpression F1 2 LEGENDE O Robinet de vidange O Fluxostat 8 Capteur de pression manom tre a changeur plaques pour ECS 4 Circulateur Soupapes d quilibrage circuit S Vase d expansion membrane dd Soupape thermostatique automatique Robinet Vanne d arr t Capteur de s curit T gt 85 C 7 Clapet anti retour Capteur de temp rature de l eau Event chambre de combustion circuit Capteur de pression du circuit g Soupape de s ret max 3 bars BH Soupapes
80. CA PELLET decorso tempo Pr40 ATTESA FIAMMA decorso tempo Pr41 temperatura fumi gt Pr13 FUOCO PRESENTE decorso tempo Pr02 temperatura ambiente lt SET temperatura 7 LAVORO temperatura fumi lt Pr14 temperatura ambiente gt SET temperatura LAVORO MODULA h temperatura acqua gt SET acqua temperatura fumi gt Pr14 PULIZIA BRACIERE con cadenza Pr03 LAVORO y ON OFF per spegnere PULIZIA FINALE Pr39 OFF Pr39 decorre dal momento 1 n cui Tfumi Pr13 Trascorso un certo tempo se la temperatura fumi non ha raggiunto il valore minimo ammesso la caldaia si pone in stato di allarme E vietato utilizzare liquidi infiammabili per l accensione In caso di continue mancate accensioni contattare il Centro di Assistenza 22 DOMUSFIRE C29 C35 C39 COLA 4 4 Fase di lavoro Conclusa in modo positivo la fase di AVVIO la caldaia passa alla modalit LAVORO che rappresenta il normale modo di funzionamento L utente pu regolare la potenza di riscaldamento attraverso i pulsanti P6 e P5 dal valore massimo di 5 ad un valore minimo di 1 L attivazione ON della funzione circuito sanitario viene visualizzato con la comparsa del segmento led A 1436 55E SBS LAVORO 3 mancanza di pellet Durante il caricamento del pellet assicurarsi che l apparecchio sia spento Il coperchio del serbatoio pellet deve rimanere sempre chiuso va aperto solamente durante il caricamento
81. COLA COLA Manuale d installazione uso e manutenzione Installation use and maintenance manual Manuel d installation d utilisation et d entretien Installations Bedienungs und Wartungsanleitung Manual de instalaci n uso y mantenimiento Caldaia a pellet mod Pellet Boiler model Po le granul s mod Pelletofen Modell Estufa de pellets mod DOMUSFIRE C29 C35 C39 484270010 M5_01 13 Hardware M Leggere attentamente le istruzioni prima dell installazione utilizzo e manutenzione Il manuale parte integrante dell apparecchio Read the instructions carefully before installation use and maintenance The manual is an integral part of the unit Lire attentivement les instructions avant d installer d utiliser et d entretenir le po le Le manuel fait partie int grante de l appareil Vor Installation Gebrauch und Wartung muss diese Anleitung aufmerksam durchgelesen werden Das Handbuch ist wesentlicher Bestandteil des Ger ts Lea atentamente las instrucciones antes de realizar la instalacion el uso y el mantenimiento EI manual es parte integrante del equipo 1 DOMUSFIRE C29 C35 C39 COLA Certificato di Garanzia La presente garanzia convenzionale e valida per gli apparecchi funzionanti a pellet destinati alla commercializzazione venduti ed installati_sul solo territorio italiano La Direttiva Europea 1999 44 CE ha per oggetto taluni aspetti della vendita e delle garanzie dei b
82. CQUA Viene attivata la procedura di scheda centro di assistenza spegnimento ALd Avviene quando la temperatura Avviene quando la sonda di Verificare la causa del problema dell acqua ha superato i limiti temperatura inserita nella ripristinando la temperatura HOT ine E prestabiliti termocamera rileva un valore elevata e riportando il valore al ACQUA Il sistema viene arrestato superiore ai 92 C normale funzionamento p Tentativo di sblocco in fase di Lo sblocco dell allarme sara ATTESA ipl ll rater to spegnimento con la caldaia calda possibile solamente a RAFFRED in fase diraffreddamento spegnimento ultimato Il controllo non rileva la quantita L ani di rinrieti Le operazioni di ripristino GUASTO Avviene quando il debimetro d aria comb ma non spegne la a essere e da DEBIMET viene scollegato caldaia esclude solo le funzioni del debimetro un centro di assistenza La pompa si accende per ei A movimentare l acqua all interno Avviene quando la temperatura Il controllo della caldaia rileva la pues PERICOLO acqua Sech sotto una certa temperatura acqua sotto i 6 C e Gel circuito elec iena GELO i na tramite id MONO a temperatura dell acqua affinch non scenda sottoi0T Avviene quando la caldaia ha Le operazioni di pulizia superato le 1800 ore di manutenzione straordinaria di SCADENZA funzionamento dal precedente i di manutenzione ripristino devon
83. ER WARMETAUSCHER BOILER PUFFER oder WARMWASSERBOILER erscheint auf dem Display bei Umschaltung von Heizung auf Warmwasserbereitung mit einer der nachstehenden Meldungen und bleibt bis zum Ende der Warmwasseranforderung von Thermostat oder Str mungsw chter 436 436 pc SEE eft 436 56E PIC SBt HEALEH HEALEH EXCHANG bOI LER ASSER bU LER 2 9 4 Anschlusspl ne Kessel Wasseranschlussplan Pelletkessel mit Pumpe Pelletkessel our Control system 7 LEGENDE Ablasshahn 8 Drucksensor Manometer 4 Umlaufpumpe Membranausdehnungsgef Hahn Sperrventil 7 R ckschlagventil Entl ftung Heizkammer Kreislauf g Sicherheitsventi P max 3 bar GQ Sicherheitsventi P max 6 bar 111 A VORLAUF Heizung AuBengewinde 1 B RUCKLAUF Heizung AuBengewinde 1 C VORLAUF Brauchwasser AuBengewinde 3 4 D RUCKLAUF Brauchwasser AuBengewinde 3 4 E Wassernetz Innengewinde 1 2 Wasserablass bei berdruck Innengewinde 1 2 1 Str mungsw chter 8 Plattenwarmetauscher f r Strangregulierventil 0 Automatisches Thermostatventil Sicherheitssensor T gt 85 C Wassertemperatursensor Drucksensor Kreislauf Installation in die Anlage einzubauende Ventile nicht im Lieferumfang des Ger ts enthalten DOMUSFIRE C29 C35 C39 COLA Wasseranschlussplan Pelletkessel mit Plattenwarmetauscher Warmwasserbereitung_07 2012 Pelletkessel Thermostat
84. F und der Kessel aktiviert den Vorgang zur Flammenmodulation ohne dass der Bediener eingreifen muss Wenn die Temperatur hingegen 280 C bersteigt erscheint die Alarmmeldung AL3 HOT ABGASE und der Kessel aktiviert den Abschaltvorgang 4 4 2 Neustart aus STANDBY Bei Aktivierung der Funktion STANDBY und des entsprechenden Raum oder Pufferthermostats schaltet der Kessel nach dem Abschalten auf Abk hlen und die Drehzahl des Saugzuggeblases wird auf den f r die Brenntopfreinigung vorgegebenen Wert eingestellt Sobald die Wassertemperatur den vorgegebenen IBI E Sollwert erreicht hat wird der Kessel wieder eingeschaltet m COOL nb 4 4 3 Reinigung des Brenntopfes W hrend des normalen Betriebs wird in regelm igen von einem Parameter vorgegebenen Zeitabst nden die Betriebsart 14 36 BRENNTOPFREINIGUNG aktiviert deren Dauer ebenfalls r e vorgegeben ist c fe 55 GBE REI ni Dun Leistungsstu Eingestellte 117 DOMUSFIRE C29 C35 C39 COLA 4 4 4 Warmwasserbereitung mit Frischwassermodul Wenn Warmwasser angefordert wird erscheint auf dem Display die Meldung SCAM SANIT und die mit dem Wasserhahn gekennzeichnete LED leuchtet auf Die Funktion wird jedoch nur ausgef hrt wenn der Kessel eingeschaltet ist und in der Heizkammer eine ausreichende Wassertemperatur erreicht hat Andernfalls wird kein Warmwasser geliefert 4 4 5 Warmwasserbereitung mit Warmwasserspeicher Diese Installat
85. K END programming only after deactivating the weekly programming To avoid unwanted startup and shutdown operations only A activate one program at a time Deactivate the daily program if the weekly program is required with this setting it is advisable to deactivate the week end program 57 Dialogue box Menu level 4 31 rz J 4 09 SERI MEEHS Eng DOMUSFIRE C29 C35 C39 COLA 4 6 2 Menu 02 User adjustments With this menu it is possible to do a number of settings as follows Set clock Before operating with the boiler it is necessary to set the current time and date so that there is a reference for possible chrono programming The electronic controller has a lithium battery model CR2032 3 Volt giving the internal clock an autonomy of more than 4 5 years with the boiler off wnenever the clock does not keep the time or a series of zeros is displayed at restart the battery must be replaced by calling an authorised service centre Standby mode On activating this function the boiler shuts down automatically after the water temperature has remained above the SET value for a fixed time The next automatic relighting will be possible only when the water temperature falls below the set value entered in the parameters table default 2 C Manual commands from the control panel have priority over programming With the selection OFF the boiler does not activate the STANDBY mode and functions normally activating the
86. Kessel f hrt nacheinander die von den Parametern fur Ebenen und Zeit vorgegeben Einschaltphasen durch und ist danach betriebsbereit sofern keine der in der nachstehenden Ubersicht aufgef hrten St rungen oder Alarme auftreten Bedingungen f r den Wechsel auf Status Dauer Vorrichtungen n chsten Status Z nder Rauchabs F rderschnecke W rmet AUS OFF OFF OFF OFF ON OFF START VORERW 40 ON ON ORE OFF Ablauf Zeit 40 Sek PELLETS VORF LLUNG Pr40 ON ON ON OFF Ablauf Zeit Pr40 WARTEN AUF FLAMME Pr41 ON ON ORBE OFF Ablauf Zeit Pr41 PELLETS EINF LLEN ON ON ON OFF Abgastemperatur gt Pr13 FEUER VORHANDEN Pro2 OFF ON ON ON Ablauf Zeit Pr02 Raumtemperatur lt Solltemperatur ARBEIT onn CN ON CN Abgastemperatur lt Pr14 Raumtemperatur lt Solltemperatur OFF ON ON ON Wassertemperatur gt Solltemperatur ARBEIT MODULIEREN Wasser Abgastemperatur lt Pr14 BRENNTOPFREINIGUNG Pri2 OFF ON ON ON mit Ablauf Pr03 ARBEIT OFF ON ON ON ON OFF zum Ausschalten Pr39 l uft ab dem Augenblick in In ass ON CEE dem Tfumi lt Pr13 ENDREINIGUNG Wenn die Abgastemperatur nach Ablauf einer bestimmten Zeit nicht den zulassigen Mindestwert erreicht hat schaltet der Kessel auf Alarmzustand Der Kessel darf nicht mit entz ndlichen Fl ssigkeiten angez ndet werden Sollten wiederholt Probleme beim Anz nden auftreten kontaktieren Sie bitte den Kundendienst 116 DOMUSFIRE
87. La per la fiducia accordataci acquistando un nostro prodotto La invitiamo a leggere e seguire attentamente consigli contenuti in questo manuale d installazione uso e manutenzione al fine di poter sfruttare al meglio le qualit del prodotto 1 2 Come utilizzare il manuale La ditta produttrice si riserva di apportare in qualsiasi momento senza preavviso alcuno eventuali modifiche tecniche od estetiche ai prodotti Le operazioni d installazione uso e manutenzione della caldaia devono soddisfare i requisiti descritti in questo manuale nonch le leggi e le norme Europee Nazionali Regionali Provinciali e Comunali disegni le misure gli schemi ed ogni altra configurazione sono qui riportati solo a scopo esemplificativo Il presente manuale rivolto all utente dell impianto di riscaldamento sanitaro e costituisce parte integrante del prodotto verificare che sia sempre a corredo dell apparecchio e in caso di vendita trasferimento ad un altro proprietario o installato in un altro luogo assicurarsi della sua presenza in modo che possa essere consultato in qualsiasi momento In caso di smarrimento o danneggiamento richiedere copia al Centro di Assistenza Tecnico autorizzato in modo che l apparecchio abbia sempre a corredo il proprio manuale Questo simbolo indica la presenza di un messaggio importante a cui prestare particolare attenzione in quanto la mancata osservanza di quanto scritto pu provocare seri danni alla caldaia e o al
88. M thodes de mesure des champs lectromagn tiques des appareils lectriques a usage domestique et analogues en relation avec l exposition humaine Normes DIN plus 51731 UNI EN14961 2 O Norm 7135 Normes relatives aux sp cifications et a la classification des granul s 1 8 Plaque d identification La plaque d identification est fix e sur la face interne du volet du r servoir granul s ou l arri re de la chaudi re Sur la plaque est inclus toutes le donnees techniques sur le table au paragraphe 1 4 1 9 Mise hors service de la chaudi re Lors d une mise hors service d finitive de l appareil d brancher l alimentation lectrique et vider compl tement le r servoir granul s La chaudi re doit tre limin e conform ment la r glementation locale en vigueur Apr s l avoir emball e soigneusement et herm tiquement contacter les services locaux de collecte et d enl vement des d chets ou le reporter au revendeur au moment de l achat d un nouvel appareil semblable Aux termes de l art 13 du D cret L gislatif n 151 du 25 juillet 2005 de mise en vigueur de la directive 2002 96 CE du 23 f vrier 2003 sur les D chets des Appareils Electriques et lectroniques relative aux mesures et aux proc dures visant pr venir la production de d chets d appareils lectriques et lectroniques d nomm s RAEE en promulguant leur r utilisation leur recyclage et d autres formes de r cup ration de sorte r duire l
89. O AUXILIAR OPCIONAL A 500 mm B 500 mm C 500 mm D 1000 mm L 1450 mm P 700 mm 137 DOMUSFIRE C29 C35 C39 COLA lt lt Sombrerete antiviento Tubo de humos Registro de inspecci n de la chimenea Toma de aire mural m n 100 cm Empalme en T con tap n de inspecci n La caldera tiene cuatro pies regulables para compensar los posibles desniveles del suelo Para nivelarla incl nela y gire el pie que necesite regulaci n 2 3 Toma de aire La caldera debe recibir del exterior el aire de combusti n necesario para un funcionamiento correcto A tal fin en proximidad de la caldera debe haber una toma de aire de pared con una superficie m nima de 100 cm que no pueda ser obstruida comunicada con el exterior y protegida por fuera con una rejilla gt El flujo de aire tambi n se puede obtener por conexi n directa al exterior mediante un tubo adecuado de 60 mm de di metro interior y longitud m xima de 1 5 m dotado de una protecci n espec fica en el extremo Tambi n es posible tomarlo del local contiguo al de instalaci n siempre que el aire entre libremente a trav s de aberturas permanentes que comuniquen con el exterior y cumplan las normas vigentes El local contiguo no debe estar en depresi n respecto al ambiente exterior a causa del tiro creado por otros equipos o por extractores El local contiguo no debe destinarse a garaje almac n de materiales combustibles o a
90. PULIZIA FINALE Temperatura H20 Boiler o Puffer 436 56 558 PULI PIA Finestra di dialogo Al termine dell operazione comparira sul display nella finestra di dialogo la scritta SPENTO 1436 Durante la fase di spegnimento non amp possibile riavviare la caldaia GRE osc fino a che la temperatura fumi non scesa al di sotto di un valore prefissato per un tempo prestabilito visualizzando sulla finestra di e SPEnE 0 dialogo la scritta ATTESA RAFFRED 24 DOMUSFIRE C29 C35 C39 COLA 4 6 Menu Premendo il tasto P3 SET si accede al menu questo suddiviso in varie livelli che permettono di accedere alle impostazioni del controllo elettronico Il prospetto seguente sintetizza la struttura del menu con le sole selezioni disponibili per l utente Abilita Crono ON OFF Crono Giorno Start 1 Giorno Stop 1 Giorno Start 2 Giorno Stop 2 Giorno Crono Settimana Start Prog 1 Stop Prog 1 Lunedi Prog 1 Martedi Prog 1 Mercoledi Prog 1 M 1 3 07 Giovedi Prog 1 M 1 3 08 Venerdi Prog 1 M 1 3 09 Sabato Prog 1 M 1 3 10 Domenica Prog 1 M 1 3 11 Start Prog 2 M 1 3 12 Stop Prog 2 M 1 3 13 Lunedi Prog 2 M 1 3 14 Martedi Prog 2 M 1 3 15 Mercoledi Prog 2 M 1 3 16 Giovedi Prog 2 M 1 3 17 Venerdi Prog 2 Menu 01 Program M 1 3 18 Sabato Prog 2 Set Crono Settimanale M 1 3 19 Domenica Prog 2 M 1 3 20 Start Prog 3 M 1 3 21 Stop Prog 3 M 1 3 22 Luned Prog 3 M 1 3 23 Martedi Prog 3 M 1 3 24 Mer
91. T ausgeschalteten Kessel ein bzw den Betriebszustand eingeschalteten Kessel auszuschalten anzeigen ON OFF SPERRE Den LE r cksetzen und wieder OFF Freigabe ausschalten Dient zum SchlieBen des Programmierungsmen s in jeder beliebigen PROGRAMMIERUNG Anderungsphase Die Anderungen werden gespeichert A Leistung oder Temperaturwert am 5 ei ARBEIT AUS Wasserthermostat des Warmwasserboilers Leistungsstufe TEMPRA SE 1 5 g verringern sofern eingeschaltet Leistung oder Temperaturwert am 6 nn ARBEIT AUS Wasserthermostat des Warmwasserboilers Leistungsstufe pus 1 5 erh hen sofern eingeschaltet Externer Kontakt Uhrenthermostat Auf der nebenstehenden Abbildung ist die Bedeutung der Statusanzeigen links am Display aufgef hrt Wenn im Display eines der Segmente aufleuchtet wurde die jeweilige in der nebenstehenden Liste aufgef hrte Vorrichtung aktiviert Heizwiderstand F rderschnecke Saugzuggebl se Aktivierung WARMWASSERKREISLAUF Aktivierung HEIZKREIS ALARM 4 3 Einschalten 4 3 1 Kontrolle vor Inbetriebnahme Vor dem Einschalten des Kessels m ssen folgende Kontrollen durchgef hrt werden Die Betriebsanleitung muss gelesen und verstanden worden sein Der Beh lter muss mit Pellets gef llt sein Die Brennkammer muss sauber sein Der Brenntopf muss sauber vollst ndig frei von eventuellen Verbrennungsr ckst nden und korrekt im Brenntopfhalter positioniert sein Feuerraumt r und Aschekasten m ssen d
92. T gt 85 C VORLAUF Heizung AuBengewinde 1 VORLAUF Brauchwasser AuBengewinde 1 2 Heizkammer Pellet RUCKLAUF Brauchwasser AuBengewinde 1 Wassernetz Innengewinde 1 2 Wasserablass bei Uberdruck Innengewinde 1 2 M 1 2 max 2 bar X oY LEGENDE Ablasshahn i Str mungsw chter ST y gt Drucksensor Manometer Plattenw rmetauscher f r 2 Umlaufpumpe Strangregulierventil Membranausdehnungsgef Automatisches Thermostatventil m Sicherheitssensor gt 85 C _ Wassertemperatursensor 8 Entl ftung Heizkammer Kreislauf Drucksensor Kreislauf 3 Sicherheitsventil P max 3 bar od Bei Installation in die Anlage einzubauende Sicherheitsventil P max 6 bar Ventile nicht im Lieferumfang des Ger ts Hahn Sperrventil R ckschlagventil enthalten 2 10 Notfallma nahmen Auf jeden Fall sind geeignete Brandbek mpfungsmittel bereit zu stellen Im Brandfall folgenderma en vorgehen Stromzufuhr sofort trennen Mit Feuerl schern l schen Sofort die Feuerwehr rufen Nicht mit Wasser l schen 112 DOMUSFIRE C29 C35 C39 COLA 3 SICHERHEITSEINRICHTUNGEN DES KESSELS 3 1 Sicherheitsabstand von entflammbaren Materialien Um das Gerat herum muss ein Mindestsicherheitsabstand von entflammbaren Materialien eingehalten werden damit sich diese nicht durch Uberhitzung entz nden die entsprechenden Abst nde sind in de
93. Total emission dust PPBT at ref 13 O laximale wassertemperatur set Set max temp fax Betriebsdruck lax working pressure 7 24 1 9 5 23 6 9 5 24 5 9 5 Behalterinhalt Klasse von Kessel rif EN303 5_2012 Boiler class rif EN303 5 2012 Druckabfall auf der Wasserseite AT 10K Water resistance AT 10K Druckabfall auf der Wasserseite AT 20K Water resistance AT 20K Abgastemperatur Fume outlet 4 linderstzug min max 10 14 0 10 0 14 Draught min max Rauchabzugsrohr 100 Fume outlet pipe Elektrische Versorgung lectrical power 230V 50Hz 6A tromaufnahme Rated input power Zundung 476 Stand by 4 160 Prid 153 me E 1300 x 700 x 698 1300 x 700 x 698 1300 x 700 x 698 Dimensions HxLxP Behalterinhalt Nennwert Reduzierter wert Der Verbrauch kann je nach Pelletart unterschiedlich sein email info anseimocola com on fine www co 521 7 624 7 141 54 16 3 5 4 18 2 5 4 7 8 37040 Arcole VR Italy Tei 045 7635780 045 6144043 90180230 Capitala Sociale E 0 Lv VR 301021 Socio Unico ammerciale 045 7639032 Fax Assistenza 045 7639030 Fax Logistica 045 6144048 lastufe com 129 DOMUSFIRE C29 C35 C39 ADVERTENCIAS GENERALES 1 1 Introducci n 1 2 Uso del manual 1 3 Normas de seguridad 1 4 Descripci n t cnica 1 5 Combustible y uso permitido 1 6 Accesorios suministrados 1 7 Normas de referenc
94. a quantit des appareils destin s au rebut et d am liorer le travail des personnes qui participent au cycle de vie de ces appareils Le symbole de la poubelle barr e report e sur l tiquette de l appareil indique qu la fin de la vie utile de ce dernier il faudra le collecter s par ment des autres d chets urbains 1 10 Instructions en cas de n cessit d intervention et de pi ces d tach es Pour toute demande d intervention et ou de pi ces de rechange contacter le revendeur l importateur de votre r gion ou le centre d assistance agr le plus proche en pr cisant toujours mod le de la chaudi re num ro de s rie date d achat liste des pi ces de rechange les anomalies de fonctionnement constat es Les interventions sur les composants doivent tre effectu es par un personnel agr et ou qualifi N Avant de proc der aux op rations s assurer que toutes les connexions lectriques sont d branch es et que la chaudi re est froide N utiliser que des pi ces de rechange d origine 73 DOMUSFIRE C29 C35 C39 COLA 2 TRANSPORT ET INSTALLATION 2 1 Conditions de livraison transport et stockage La chaudi re est livr e sous film Nylon et emball e sur une palette caisse en bois au terme du cycle de production et du test d homologation sur ligne de montage a l usine La chaudi re et son emballage peuvent tre soulev s a l aide d un chariot l vateur en introduisant les fourches d une longueur ad q
95. a caldaia e ruotare il piedino interessato al livellamento 2 3 Presa d aria La caldaia deve disporre dell aria di combustione necessaria a garantire il regolare funzionamento attraverso delle prese d aria esterna e precisamente in prossimit della caldaia sia praticata una presa d aria a parete comunicante con l esterno di superficie minima di 100 cm opportunamente posizionata da non essere ostruita e protetta esternamente da una griglia gt oppure con collegamento direttamente all esterno con un appropriato tubo con diametro interno pari a 60mm e con lunghezza massima di 1 5 m opportunamente protetta all estremit da idonea protezione oppure attraverso il locale adiacente a quello d installazione purch il flusso d aria sia libero di transitare attraverso aperture permanenti comunicanti con l esterno rispondenti ai requisiti sopra descritti Il locale adiacente non deve essere messo in depressione rispetto all ambiente esterno per effetto del tiraggio indotto dalla presenza di altri possibili apparecchi o di dispositivi di aspirazione Il locale adiacente non pud essere adibito ad auto rimessa magazzino di materiale combustibile e tantomeno ad attivit con pericolo d incendio L attacco di aspirazione o presa d aria della caldaia collocato posteriormente ed di sezione circolare con diametro pari a 60 mm 2 4 Scarico fumi di combustione Lo scarico fumi deve essere fatto attraverso un allacciamento a Norma ad un
96. a canna fumaria Si raccomanda all installatore di verificare l efficienza e lo stato della canna fumaria la rispondenza alle A regole e o disposizioni locali norme nazionali ed europee Utilizzare solo tubi e raccordi certificati con adeguate guarnizioni che garantiscono la tenuta Evietato l utilizzo di tubi metallici flessibili o in fibro cemento In caso di incendio spegnere la caldaia staccare l alimentazione elettrica e chiamare tempestivamente i Vigili del fuoco ed evitare continui tentativi di spegnimento 13 DOMUSFIRE C29 C35 C39 COLA 2 4 1 Tipologie delle installazioni Di seguito vengono elencate definizioni e requisiti per realizzare secondo Norma italiana UNI10683 per la corretta installazione di uno scarico fumario CAMINO condotto verticale avente lo scopo di raccogliere ed espellere ad un opportuna altezza dal suolo i prodotti di combustione provenienti da un solo apparecchio nei casi consentiti di uno er Wa Requisiti tecnici CAMINO essere a tenuta dei prodotti di combustione L sy isolato e coibentato in funzione dell impiego Canna LT avere un andamento prevalentemente verticale con deviazioni dall asse lt 45 Raccordo essere adeguatamente distanziato da materiali infiammabili con P umi intercapedine d aria o isolante avere sezione interna preferibilmente circolare costante libera ed indipendente bi Y u consigliato che
97. a presenza di biancheria stesa ad asciugare E vietato manipolare sostanze facilmente infiammabili o esplosive nelle vicinanze della caldaia durante il suo funzionamento 6 DOMUSFIRE C29 C35 C39 COLA vietato modificare i dispositivi di sicurezza o di regolazione senza espressa autorizzazione del costruttore Qualsiasi manomissione e o sostituzione non autorizzata di particolari non originali della caldaia pu causare pericolo per l incolumit dell utente e solleva il costruttore da ogni responsabilit civile e penale Utilizzare solo ricambi originali consigliati dal produttore n caso di anomalie di funzionamento la caldaia pu essere riaccesa solo dopo avere ripristinato la causa del problema ed in ogni caso non disabilitare i sistemi di sicurezza n caso d incendio spegnere l impianto di riscaldamento staccare l alimentazione elettrica e munirsi di adeguati sistemi per estinguere le fiamme e o richiedere l intervento dei Vigili del Fuoco Pulire regolarmente il braciere ad ogni accensione e o ricarica pellet Evitare la formazione di fumo ed incombusti in fase di accensione e o durante il normale funzionamento l eccessivo accumulo di pellet incombusto nel braciere deve essere rimosso manualmente prima di procedere con una nuova accensione Eseguire regolarmente la manutenzione della caldaia almeno una volta all anno pianificando per tempo l intervento con il personale del Centro di Assistenza Tecn
98. agine poste in successione 4 6 5 Menu 05 Regolazioni installatore Tale selezione riservata al solo tecnico autorizzato del centro di assistenza competente eventuali modifiche fatte in modo casuale possono provocare gravi danni che escludono da i La modifica dei parametri tecnici sul menu 05 deve essere effettuata da personale autorizzato e qualsiasi responsabilit la ditta COLA 4 7 Termostato cronotermostato esterno Se si desidera utilizzare un termostato esterno rivolgersi ad un tecnico autorizzato e per l installazione seguire le seguenti indicazioni spegnere l apparecchio agendo sull interruttore generale posto sul lato posteriore e staccare il cavo dall alimentazione smontare la pannellatura laterale per accedere al controllo elettronico con riferimento allo schema elettrico collegare i due cavi del termostato sui relativi morsetti TERM della scheda rimontare il tutto e verificare il corretto funzionamento Per ognuna delle impostazioni tutte le funzioni del menu non cambiano e la segnalazione del collegamento avviene con l accensione del led a segmento sullo barra degli stati nel display Il termostato se soddisfatto fa spegnere la caldaia visualizzando la funzione STAND BY sul pannello se attiva 4 8 Periodo di inattivit fine stagione Se la caldaia non viene utilizzata per lunghi periodi e o a fine di ogni stagione consigliato operare come segue togliere
99. aia per almeno 45 minuti Ripristinare il termostato premendo il pulsante vicino all interruttore dietro la caldaia figura a lato dopo aver rimosso la protezione e precisamente T1 termostato temperatura acqua termocamera T2 termostato temperatura canale alimentazione pellet Riavviare la caldaia come da normale avvio Temperatura d intervento termostato serbatoio pellet gt 85 C Temperatura d intervento termostato termocamera gt 95 3 5 Sicurezza contro il ritorno di fiamma sul canale alimentazione pellet Le soluzioni che impediscono il ritorno di fiamma sono depressione in camera di combustione ved par 3 2 gt la forma a sifone del canale di alimentazione pellet gt la sicurezza sulla temperatura del serbatoio ved par 3 4 3 6 Dispositivo elettrico di protezione dalla sovracorrente L apparecchio protetto contro la sovracorrente da fusibile i da 2A inseriti sull alimentazione dell interruttore generale della caldaia dislocato posteriormente 3 7 Sicurezza sovrapressione circuito idraulico Eventuale sovrapressione dell acqua all interno della camera per P gt 3 bar viene scaricata attraverso l intervento della valvola di sicurezza installata sull impianto idraulico interno alla stufa A E vietato manomettere i dispositivi di sicurezza 3 8 Guasto ventilatore estrazione fumi Se per qualsiasi motivo il ventilatore di estrazione fumi si ferma il controllo elettronico blocca istantaneamente la
100. alore di SET impostato d Ge A d 4 4 3 Pulizia del braciere Durante la normale operativita nella modalita lavoro a intervalli prestabiliti da parametro viene attivata la modalit PULIZIA BRACIERE per una durata prefissata Potenza impostata 23 DOMUSFIRE C29 C35 C39 COLA 4 4 4 Acqua calda sanitaria con scambiatore rapido Quando viene richiesta acqua calda sanitaria nel display compare la scritta SCAM SANIT e si accende il LED indicato dal rubinetto La funzione comunque viene eseguita solamente se la caldaia accesa ed ha raggiunto una sufficiente temperatura dell acqua all interno della termocamera Nei restanti casi il servizio non viene fornito 4 4 5 Acqua calda sanitaria con bollitore ad accumulo Questo tipo di installazione richiede l utilizzo di un termostato esterno o di una sonda acqua che misuri la temperatura dell acqua sanitaria del bollitore Quando la temperatura si abbassa al di sotto della temperatura di SET impostata si attiva la funzione sanitario nel display della caldaia compare la scritta BOILER SANIT e si accende il LED indicato dal rubinetto fintantoch viene soddisfatta la richiesta Se la caldaia nella fase di ATTESA RICHIESTA si accende automaticamente e si pone in LAVORO Raggiunta la temperatura di lavoro dell acqua nella termocamera si attiva la fornitura d acqua al bollitore Quando la temperatura di SET del bollitore soddisfatta la CALDAIA converte il ca
101. ammieren Bei Auftreten von Betriebsst rungen darf der Kessel erst wieder eingeschaltet werden nachdem die Ursache f r das Problem beseitigt wurde andernfalls den Kundendienst kontaktieren Der Hersteller haftet nicht f r St rungen Sch den oder Unf lle die auf die Missachtung bzw Nichteinhaltung der Hinweise in dieser Betriebsanleitung zur ckzuf hren sind 1 4 Technische Beschreibung Der Kessel darf ausschlieBlich mit Pellets beschickt werden und l sst sich problemlos mit Heizungs und Warmwasserbereitungsanlage installieren Seine automatischen Kontrollsysteme sorgen f r eine optimale Warmeleistung und eine vollst ndige Verbrennung Die vorhandenen Sicherheitssyteme garantieren einen sowohl f r die Komponenten des Kessels als auch f r den Benutzer sicheren Betrieb Das Ger t dient nur zur Erhitzung von Wasser auf eine Temperatur unter dem Siedepunkt Das vorschriftsm ig installierte Ger t funktioniert unter jeder klimatischen Bedingung bei kritischen Witterungsverh ltnissen starker Wind Frost usw k nnen allerdings die Sicherheitssysteme ausgel st werden die den Kessel ausschalten 101 DOMUSFIRE C29 C35 C39 COLA Technische Daten des Kessels KESSEL Heating Boiler ype hits 290 6 4 344 6 4 383 6 4 leating input armeleistung Wasser 27 4 5 78 32 4 5 78 34 9 5 78 empece A ei fficiency IStundl Verbrauch O Emission bei 1096 Oz nHm Emission bei 10 O mission C
102. ande de chaleur est reconnue par exemple pour chauffer l eau ou pour l eau chaude sanitaire si la fonction est disponible M3 56 ALL UAE Temp rature H20 Ballon Puffer Bouton P4 La chaudi re ex cute successivement les phases de mise en route selon les param trages d finis qui en g rent les niveaux et les temps d ex cution jusqu l obtention du r gime normal moins que ne surviennent des anomalies ou ne se d clenchent des alarmes selon le tableau suivant tat dur e dispositifs conditions pour passage l tat suivant asp allumeur des VS pete chang S in fum es ETEINT gt OFF OFF OFF OFF ON OFF START PRECHAUF 40 ON ON OFF OFF temps coul 40 PRECHARG GRANULES Pr40 ON ON ON OFF temps coul Pr40 ATTENTE FLAMME Pr41 ON ON OFF OFF temps coul Pr41 CHARGEMENT DES GRANULES ON ON ON One temp rature des fum es gt Pr13 FEU PRESENT Pro2 OFF ON ON ON temps coul Pr02 E temp rature ambiante SET temp rature FONCTIONNEMENT Sup ON CN EN temp rature fum es lt Pr14 temp rature ambiante lt SET temp rature FONCTIONNEMENT OFF ON ON ON temp rature eau gt SET eau temp rature fum es MODUL lt 14 NETTOYAGE DU BRASIER pile QE CN EN ON avec cadence Pr03 FONCTIONNEMENT OFF ON ON ON ON OFF pour teindre NETTOYAGE FINAL Pr39 OFF ON OFF Pr39 s coule des que Tfum es lt Pr13
103. anelling to access the electronic controller referring to the wiring diagram connect the two thermostat wires to the respective board TERM terminals refit everything and check correct operation All the menu functions do not change for each of the settings and signalling of the connection occurs with lighting up of the segment LED on the status bar of the display If met the thermostat shuts down the boiler displaying the STANDBY function on the panel if on 4 9 Idle period end of season If the boiler is not used for long periods and or at the end of each season it is advisable to proceed as follows remove all the pellets from the hopper disconnect the power supply clean thoroughly and if necessary have any damaged parts replaced by qualified personnel protect the boiler from dust with suitable covering store in a dry and safe place protected from atmospheric agents 5 BOILER CLEANING Boiler cleaning is very important to prevent poor combustion deposits of ash and unburnt products in the brazier reduced thermal efficiency The boiler must only operate with the ash and fire door always closed The door seals must be checked periodically to prevent air from entering and ensure combustion chamber low pressure Routine cleaning is normally carried out by the customer following the instructions in the manual whereas extraordinary maintenance at least once a year must be performed by the authorised Servi
104. antenimiento para aprovechar al m ximo las caracter sticas de este equipo 1 2 Uso del manual El fabricante se reserva el derecho a realizar modificaciones t cnicas o est ticas de los productos en cualquier momento y sin preaviso Las operaciones de instalaci n uso y mantenimiento de la caldera deben cumplir los requisitos expuestos en este manual as como las leyes y las normas europeas nacionales regionales provinciales y municipales Las figuras y medidas los esquemas y dem s informaci n tienen solo valor indicativo El presente manual est dedicado al usuario del sistema de calefacci n agua caliente sanitaria y es parte integrante del producto En caso de venta o cesi n a otra persona o de instalaci n en otro lugar debe acompa ar al equipo para futuras consultas Si el manual se pierde o se da a solicite otro ejemplar al Centro de asistencia t cnico autorizado Este s mbolo indica la presencia de un mensaje importante que requiere especial atenci n porque su incumplimiento puede causar da os graves a la caldera y a las personas Los detalles que precisan mayor atenci n se destacan mediante el texto en negrita 1 3 Normas de seguridad Leer este manual antes de realizar operaciones de instalaci n uso y mantenimiento de la caldera Hacer realizar la instalaci n la conexi n el ctrica la prueba y el mantenimiento por un t cnico autorizado Conectar la caldera a una chimenea
105. anuelle Steuerungen vom Bedienpanel haben Vorrang vor der Programmierung Bei Wahl von OFF aktiviert der Kessel nicht die Betriebsart STANDBY und funktioniert normal mit Aktivierung der Funktion MODULATION wenn die Temperatur den Sollwert Ubersteigt Erste Pelletf llung Bei Einstellung dieser Funktion kann der Getriebemotor bei ausgeschaltetem oder kaltem Kessel f r die Dauer von 90 Sek in Betrieb gesetzt werden um eine erste Pelletf llung durchzuf hren Die F llung wird mit der Taste P1 gestartet und mit der Taste P4 abgebrochen Pellettyp Wenn diese Funktion aktiv ist und die Tasten P1 oder P2 gedr ckt werden wird die Pelletf llung erh ht bzw reduziert um Verbrauch und Verbrennung je nach verwendetem Pellettyp zu optimieren Erste Pelletf llung Schnecke 2 Bei Einstellung dieser Funktion kann der Getriebemotor des zus tzlichen Beh lters f r eine vorgegebene Vorf llung in Betrieb gesetzt werden Die F llung wird mit der Taste P1 gestartet und mit der Taste P4 abgebrochen 4 6 3 Men 03 Benutzerdefinierte Einstellungen Mit diesem Men k nnen folgende Einstellungen vorgenommen werden Sprache Mit dieser Option kann die gew nschte Dialogsprache unter den im Men verf gbaren Sprachen gew hlt werden und zwar ITALIENISCH FRANZ SISCH ENGLISCH DEUTSCH SPANISCH Summer Mit dieser Option kann der Signalton des Kessels aktiviert oder deaktiviert werden Beleuchtung Mit dieser Option kann die Helligkeit
106. arantir une combustion efficace S assurer galement que les orifices des tubes lat raux du support du brasier pour la distribution d air secondaire ne pr sentent aucun r sidu de combustion ou de cendre D s que cela s av re n cessaire nettoyer la vitre de la porte du foyer pour pouvoir contr ler la pr sence de la flamme a l int rieur de la chambre de combustion Le brasier doit parfaitement plaquer sur tout le p rim tre de son support sans laisser aucun interstice pour le passage d air t bns Brasier encrass Brasier propre Support de brasier 5 2 Nettoyage du cendrier Le cendrier est situ directement sous l ensemble brasier et support de brasier Pour le nettoyage ouvrir la porte du cendrier et aspirer la cendre et tout autre r sidu de combustion avec un aspirateur appropri A la fin du nettoyage fermer la porte Le d cendrage doit se faire tous les 2 3 jours en fonction de l utilisation de la chaudi re 91 DOMUSFIRE C29 C35 C39 COLA 5 3 Nettoyage de l extracteur de fum es et de la chambre de combustion Nettoyer au moins une fois par an la chambre de combustion en liminant tous les r sidus de combustion des conduits de fum es et du parcours de fum es Pour effectuer cette op ration retirer le couvercle sup rieur de la chaudi re le couvercle de la chambre de combustion et la trappe de visite inf rieure en d vissant leurs vis de fixation respectives puis proc der au nettoyage des turbulat
107. arga de agua en la instalaci n Una vez realizadas las conexiones hidr ulicas se puede proceder a la CARGA del equipo y de la instalaci n Abra todas las v lvulas de purga de aire de radiadores colectores caldera e instalaci n Abra gradualmente la llave de carga de agua verificando que las v lvulas de purga de aire funcionen correctamente Cargue lentamente el agua en la instalaci n para expulsar todo el aire por los purgadores hasta alcanzar la presi n de funcionamiento para un sistema de vaso cerrado de 1 1 a 1 5 bar Concluida la operaci n cierre la llave de carga y controle que todos los purgadores hayan evacuado el aire del lado de la instalaci n La realizaci n de un sistema de calefacci n y la instalaci n de la caldera deben cumplir todas las normas A nacionales regionales provinciales y locales del lugar de instalacion 2 9 2 Caracteristicas del agua de la instalacion Las caracter sticas qu micas y f sicas del agua de la instalaci n y de rellenado son importantes para asegurar las prestaciones y la duraci n de la caldera Con aguas de baja calidad el inconveniente m s frecuente son las incrustaciones calc reas que reducen el intercambio t rmico y generan fen menos de corrosi n Se recomienda analizar el agua y si se dan las condiciones indicadas m s abajo realizar un tratamiento correctivo alta dureza gt 20 f gran cantidad de agua de reintegro o llenados frecuentes instalaciones comp
108. aro i seguenti dati modello della caldaia numero di serie data di acquisto lista dei ricambi e informazioni sulle anomalie o malfunzionamenti riscontrati Prima di ogni intervento accertarsi che sia disinserito ogni collegamento elettrico e che la caldaia sia fredda Utilizzare solo ricambi originali N Gli interventi sui componenti devono essere effettuati da personale autorizzato e o qualificato 11 DOMUSFIRE C29 C35 C39 COLA 2 TRASPORTO ED INSTALLAZIONE 2 1 Condizioni di fornitura trasporto e immagazzinamento La caldaia viene consegnata avvolta su protezione in nylon e imballata su un bancale gabbia in legno dopo aver completato il ciclo produttivo e il collaudo funzionale in linea di montaggio presso la fabbrica del produttore Il sollevamento della caldaia completa di imballo pu essere effettuato mediante un carrello elevatore inserendo le forche di adeguata lunghezza nelle apposite sedi del bancale in legno E necessario accertarsi che i dispositivi utilizzati per il sollevamento e il trasporto siano in grado di sopportare il peso della caldaia indicato sulla targhetta di identificazione e sul presente manuale Evitare il passaggio del carico su zone nelle quali la caduta del carico pu essere un pericolo Durante il trasporto e l immagazzinamento evitare l esposizione a pioggia o umidit persistente La caldaia va movimentata solo in posizione verticale mediante carrelli in appoggio alla base A Per rimu
109. ars on the control panel and the stove activates the flame modulation procedure without any user intervention whereas if the temperature exceeds 280 C the alarm AL3 HOT FUMES appears and the boiler activates the shutdown procedure 4 4 2 Restart from STANDBY With activation of the STANDBY function and ambient or Puffer thermostat at the end of shutdown the boiler goes to cooling status bringing the fume extractor speed to the set value for brazier cleaning Relighting occurs as soon as the water temperature reaches the SET value 4 4 3 Cleaning the brazier During normal operation in work mode the BRAZIER CLEANING mode is activated at parameter fixed intervals for a set duration 54 ALE COOL nb DOMUSFIRE C29 C35 C39 COLA 4 4 4 DHW with rapid heat exchanger When hot water is required the display shows the message DHW EXCH and the LED indicated by the tap lights up The function is carried out only if the boiler is on and the water inside the heating chamber has reached a sufficient temperature In the remaining cases the service is not provided 4 4 5 DHW with storage tank This type of installation requires the use of an external thermostat or a water probe which measures the storage tank water temperature When the temperature drops below the SET temperature the DHW function is activated the boiler display shows the message DHW STORAGE TANK and the LED indicated by the tap lights up until the request is me
110. artungsarbeiten zusammengefasst die f r den korrekten Gebrauch und Betrieb des Kessels erforderlich sind 1 Jahr Teile Intervall 1 Tag 2 3 Tage 1 Monat 2 3 Monate auBerordentliche Art der Reiniaun ordentliche ordentliche ordentliche ordentliche Reinigung wird vom gung Reinigung Reinigung Reinigung Reinigung technischen Kundendienst durchgef hrt Brenntopf n Aschefach kasten n Rohrbtindel Heizkammer n n Sammelleitung Saugzuggeblase Dichtung Feuerraumtur n Aschet r Schornsteinrohr Rauchrohr n 5 1 Reinigung Brenntopf Brenntopfhalter Den Brenntopf herausnehmen und eventuelle R ckst nde die sich in der Brennkammer und im Brenntopfhalter abgelagert haben beseitigen Hierf r kann ein Aschesauger verwendet werden Diese Arbeit muss t glich vorgenommen werden vor allem wenn sich unverbranntes Material angesammelt hat damit eine optimale Verbrennung gew hrleistet ist da durch die L cher des Brenntopfes die f r die Verbrennung erforderliche Luft dringen muss 122 DOMUSFIRE C29 C35 C39 COLA Die Offnungen der seitlichen Rohre des Brenntopfhalters f r die Verteilung der Sekund rluft m ssen frei von Verbrennungsr ckst nden und angesammelter Asche sein Falls erforderlich das Schauglas der Feuerraumt r reinigen damit die Sichtkontrolle der Flamme in der Brennkammer m glich ist Der Brenntopf muss b ndig und luftdicht auf dem Brenntopfhalter aufliegen und zwar
111. as de funcionamiento no volver a encender la caldera sin haber resuelto la causa del inconveniente y no desactivar en ning n caso los dispositivos de seguridad caso de incendio apagar la calefacci n desconectar la alimentaci n el ctrica utilizar un extintor apropiado y llamar a los bomberos si el fuego no se apaga de inmediato Limpiar correctamente el brasero a cada encendido o recarga de pellets Evitar la formaci n de humo y de material inquemado durante el encendido y el funcionamiento Si se acumula mucho pellet sin quemar en el brasero quitarlo manualmente antes del pr ximo encendido Al menos una vez al a o llamar al centro de asistencia autorizado para que efect e el mantenimiento general de la caldera caso de anomal as de funcionamiento no volver a encender la caldera sin haber resuelto la causa del inconveniente En caso de necesidad llamar al centro de asistencia El fabricante no asume ninguna responsabilidad por inconvenientes roturas o accidentes debidos a la inobservancia de las indicaciones dadas en el presente manual 1 4 Descripci n t cnica La caldera funciona solo con pellets y se puede conectar f cilmente a los sistemas de calefacci n y agua sanitaria Est provista de dispositivos autom ticos de control que aseguran un rendimiento t rmico ideal y una combusti n completa Adem s los dispositivos de seguridad garantizan un funcionamiento sin riesgos para la caldera y para los usua
112. assistance agr au moins une fois par an d branch e Eliminer les d chets du nettoyage conform ment a la r glementation locale en vigueur Il est interdit d allumer la chaudi re si elle est d pourvue de son habillage viter la formation de fum e ou d imbr l s pendant l allumage et ou le fonctionnement normal i Les op rations de nettoyage de toutes les parties doivent tre faites lorsque la chaudi re est froide et Voici le tableau r capitulatif des interventions de contr le et ou d entretien utiles pour le fonctionnement correct de la chaudi re Organes ou parties P riode 1 jour 2 3 jours 1 mois 2 3 mois Op ration nettoyage nettoyage nettoyage nettoyage effectu par le centre courant courant courant courant d assistance Brasier Cendrier n Faisceau tubulaire de la chambre de combustion 5 Collecteur extracteur des n fum es Joint porte foyer cendrier n Conduit de fum e conduit de n raccordement 5 1 Nettoyage du brasier porte brasier Enlever le brasier et liminer les r sidus de cendre qui se sont d pos s dans la chambre de combustion et dans le support de brasier Il est conseill d utiliser un aspirateur appropri Cette op ration doit tre effectu e tous les jours surtout en pr sence de d p ts d imbr l s pour permettre a l air de combustion de passer a travers les orifices du brasier de sorte g
113. ate f r den Hausgebrauch und ahnliche Zwecke Teil 1 Norm EN 60335 2 102 Sicherheit elektrischer Ger te f r den Hausgebrauch und ahnliche Zwecke Teil 2 Norm EN 55014 1 Elektromagnetische Vertraglichkeit Anforderungen an Haushaltsger te Elektrowerkzeuge und ahnliche Elektroger te Teil 1 St raussendung Norm EN 55014 2 Elektromagnetische Vertraglichkeit Anforderungen an Haushaltsger te Elektrowerkzeuge und hnliche Elektroger te Teil 2 St rfestigkeit Produktfamiliennorm Norm EN 61000 3 2 Grenzwerte f r Oberschwingungsstr me Ger te Eingangsstrom x16 je Leiter Norm EN 61000 3 3 Begrenzung von Spannungsschwankungen und Flicker in Niederspannungs Versorgungsnetzen f r Ger te mit einem Bemessungsstrom s 16 A je Leiter Norm EN 62233 Verfahren zur Messung der elektromagnetischen Felder von Haushaltsgeraten und ahnlichen Elektroger ten im Hinblick auf die Sicherheit von Personen in elektromagnetischen Feldern Normen DIN Plus 51731 EN 14961 2 Norm M 7135 Normen ber die Spezifikation und Klassifizierung von Pellets 1 8 Typenschild Das Typenschild befindet sich innen an der T r des Pelletbeh lters oder an der Kesselr ckwand Das Typenschild enth lt alle technischen Daten in der Tabelle par 1 4 1 9 AuBerbetriebsetzung des Kessels Wird das Ger t definitiv auBer Betrieb genommen muss er vom Stromnetz getrennt und die Pellets aus dem Beh lter entleert werden F r die Entsorgung muss
114. atures de fonctionnement basses voir paragraphe programmation des temp ratures pendant l allumage le fonctionnement et l extinction la chaudi re peut mettre des grincements cause de la dilatation thermique 4 2 Description du tableau de commande Le tableau de commande comprend un cran LCD r tro clair une touche d allumage extinction marche arr t P4 une touche de fonction SET MENU quatre touches de menu P1 P2 P5 Pe et 7 LED de signalisation de l tat de fonctionnement de la chaudi re Indicateurs d tat cran LCD r tro clair Indications cran n Boutons de configuration Boutons de ss ws configuration ade hr T et de s lection l Bouton de A i mise en marche s lection R cepteur IR Le tableau permet l allumage et l extinction la marche l arr t de la chaudi re la r gulation pendant le fonctionnement et le param trage des programmes de gestion et d entretien L cran affiche toutes les informations sur l tat de fonctionnement de la chaudi re Pour acc der au menu appuyer sur la touche CONSIGNE SET P3 appuyer sur les touches P5 P6 pour d rouler les menus appuyer sur une des touches d augmentation diminution P1 P2 pour ajuster le param tre d sir appuyer sur la touche CONSIGNE SET P3 pour confirmer la valeur du param tre 82 DOMUSFIRE C29 C35 C39 COLA
115. au lat ral 4 Couvercle avant 5 Porte ext rieure isol e 6 Panneau arri re Fi y G KEY 6 3 Composants internes de la chaudi re N y N ESA LE L gende Wi N Y 1 Pommeau avec tige filet e 2 Axe de rallonge du dispositif de secouage des turbulateurs 3 Ecrou de serrage bague 4 Bague de coulissement de l axe 5 Couvercle ext rieur 6 Protection thermique sup rieure 7 Protection interm diaire 8 Protection en vermiculite sup rieure 9 Protection en vermiculite lat rale 10 Protection thermique a l ext rieur de la chambre 11 Couvercle de soutien des protections 12 Support des turbulateurs 13 Turbulateurs 14 Porte du foyer 15 Soupape de s ret 16 Porte du cendrier 17 Tiroir du cendrier 18 Chambre de combustion HA 93 DOMUSFIRE C29 C35 C39 COLA Vues clat es 1 Groupe brasier 2 Groupe extracteur des fum es 3 Groupe vis sans fin L gende 1 Brasier 2 Support de brasier 3 D viateur interne 4 Tuyau d aspiration d air 5 R sistance lectrique 6 Joints 7 D bitm tre L gende 1 extracteur des fum es 2 Joint thermique 3 Moteur extracteur des fum es 4 Tuyau d vacuation des fum es 5 Joint L gende 1 Joint de r servoir convoyeur 2 Flasque d arr t mo
116. auf der gesamten Umrandung Brenntopf verschmutzt Brenntopf sauber Brenntopfhalter sauber 5 2 Reinigung des Aschebeh lters Direkt unter dem Brenntopf dem Brenntopfhalter befindet sich der Aschebeh lter Um diesen zu reinigen die Aschet r ffnen und mit einem Aschesauger die Asche und eventuelle Verbrennungsr ckst nde entfernen Nach der Reinigung muss die T r geschlossen werden Die Reinigung des Aschebehalters muss je nach Kesselgebrauch alle 2 3 Tage durchgef hrt werden 5 3 Reinigung des Saugzuggebl ses und der Brennkammer Mindestens einmal j hrlich muss die Brennkammer gereinigt und alle Verbrennungsr ckst nde von den innen verlaufenden Rauchrohren und von der Abgasf hrung entfernt werden Hierzu nach L sen der entsprechenden Befestigungsschrauben die obere Kesselabdeckung die Abdeckung der Heizkammer sowie die untere Inspektionsluke entfernen und dann die Turbulatoren und die Rauchrohre in der Kammer reinigen Au erdem muss unbedingt das hinter dem unteren Rauchrohr befindliche Saugzuggebl se gereinigt werden das ber die Offnung der Inspektionsluke hinter dem Aschekasten zug nglich ist Alle 3 4 Monate die Innenw nde der Brennkammer und des oberen Abgassammlers mit geeigneten Utensilien Pinseln B rsten reinigen und gegebenenfalls die Vermiculitwand auswechseln die als Verschlei material gilt Alle 1800 Betriebsstunden fordert der Kessel mit der Meldung SERVICE F LLIG eine nicht von Garantie gedeckt
117. bimetro difettoso devono essere condotte un centro di assistenza E onde ani Avviene quando il trasduttore di Verificare la causa del ALE Srog pressione inserito nel circuito problema ripristinando la dell acqua non rientra nei valori AA PRESS di corretto f nzionamento idraulico rileva una pressione pressione del circuito e ACQUA za erem viene arrestato inferiore o superiore ai limiti riportando al valore di normale prestabiliti funzionamento Il termostato di sicurezza ha Verificare la causa dello Avviene nel caso di intervento rilevato una temperatura eccessivo surriscaldamento ALA del termostato di sicurezza della superiore alla soglia di taratura Sbloccare il termostato SICUREZ temperatura acqua della termo per un surriscaldamento aj ni H20 camera con T gt 95 C dell acqua della termo camera INS i Sa Il sistema viene arrestato bloccando il funzionamento del surriscaldamento agendo su motoriduttore pulsante di ripristino AL b paliar i der Menu up d Il controllo rileva che il rel Le operazioni di ripristino ERRORE Ger comando motoriduttore in devono essere condotte da un TRIAC COC ii sistema viene arrestato avaria contatti incollati centro di assistenza Avviene di guasto della sonda AL c di rilevamento della T acqua La sonda guasta Le operazioni di ripristino SONDA visualizzando T H20 0 La sonda scollegata dalla devono essere condotto da un A
118. brir la puerta exterior tire hacia fuera Para abrir las puertas interiores inserte la manija suministrada y girela en sentido horario Manija para abrir y cerrar las puertas de la camara y del cenicero Abrir sentido antihorario Cerrar sentido horario ve a 1 5 Combustible y uso permitido Las calderas de pellets funcionan exclusivamente con pellets pastillas de diferentes maderas conformes a la norma DIN plus 51731 EN 14961 2 o O Norm M 7135 con las siguientes caracter sticas Poder calor fico m n 4 8 kWh kg 4180 kcal kg Densidad 680 720 kg m3 Humedad m x 10 en peso Di metro 6 0 5 mm Porcentaje de cenizas m x 1 5 en peso Longitud m n 6 mm m x 30 mm Composici n 100 madera sin tratar proveniente de la industria maderera o del postconsumo sin a adido de aglomerantes y sin corteza conforme a las normas vigentes Embalaje en sacos de material ecocompatible o biodegradable o de papel El dep sito de pellets est en la parte posterior de la caldera La tapa del dep sito se encuentra en la parte superior y la carga se efect a manualmente solo con la caldera apagada y con cuidado de que los pellets no sobresalgan ni se caigan del dep sito El uso de pellet con caracter sticas distintas a las del utilizado por el t cnico durante el primer encendido exige una recalibraci n de los par metros de carga Esta operaci n no est cubierta por la garant a Guarde el pellet e
119. ce Centre Cleaning operations for all parts must be carried out with the boiler unplugged and cold A Dispose of cleaning waste in accordance with the current local regulations The boiler must not be operated without its cladding Avoid the creation of smoke and unburnt products during lighting and or normal operation Given below are the control and or maintenance operations for correct boiler use and operation 1 year Parts Period 1 day routine 2 3 days month 2 3 months extraordinary cleaning Type of cleaning cleaning cleaning cleaning cleaning carried out by the Service Centre Brazier n Ash compartment box n Heating chamber tube bundle n n Manifold fume extractor n n Ash fire door seal n Pipe flue connection n 5 1 Cleaning the brazier brazier holder Remove the brazier and the ash deposited in the combustion chamber and brazier holder A suitable vacuum cleaner may be used for this purpose This operation must be carried out daily especially in case of accumulated unburnt matter to ensure perfect combustion conditions since the brazier holes allow the flow of combustion air Also make sure the secondary air holes in the side pipes of the brazier holder are free of any combustion residuals and ash When necessary clean the fire door glass for visually checking the flame inside the combustion chamber The brazier must rest on the brazier holder and precisely on the en
120. ci t COLA garantit ses produits selon les normes actuellement en vigueur l exception des parties qui sont soumises une usure normale Pour les conditions de garantie s adresser l importateur ou au repr sentant autoris qui pourra accorder une extension de la dur e contractuelle constructeur sous sa propre responsabilit La garantie d choit automatiquement et de plein droit pour tous les dommages ruptures ou incidents caus s par l inobservation ou l inapplication des instructions contenues le pr sent manuel Die Firma COLA garantiert ihre Produkte gem den derzeit geltenden Bestimmungen mit Ausnahme der Verschlei teile F r die Garantiebedingungen wenden Sie sich bitte an den Importeur oder an den autorisierten Vertreter der die obligatorische Garantielaufzeit auf ausschlie lich eigene Verantwortung verl ngern kann Die Garantie des Produkts erlischt im Fall von St rungen eines Defekten oder Unf llen die auf die Missachtung der in dieser Anleitung enthaltenen Anleitungen zur ckzuf hren sind ee 130 161 La Empresa Cola Srl garantiza sus productos seg n las normas actualmente en vigor excluyendo las piezas expuestas a normal usura Para las condiciones de garantia dirijanse al importador o vendedor autorizado que puede agregar el periodo de garantia obligatoria con un periodo suplementar bajo su total y unica responsabilidad La garantia del prododucto decae por qualquier incovenitente de rotura o incidente debido a
121. coled Prog 3 M 1 3 25 Gioved Prog 3 M 1 3 26 Venerd Prog 3 M 1 3 27 Sabato Prog 3 M 1 3 28 Domenica Prog 3 M 1 3 29 Start Prog 4 M 1 3 30 Stop Prog 4 M 1 3 31 Luned Prog 4 M 1 3 32 Marted Prog 4 M 1 3 33 Mercoledi Prog 4 M 1 3 34 Giovedi Prog 4 M 1 3 35 Venerd Prog 4 M 1 3 36 Sabato Prog 4 M 1 3 37 Domenica Prog 4 M 1 4 01 Crono Week End M 1 4 02 Start 1 Week End Program Week End M 1 4 03 Stop 1 Week End M 1 4 04 Start 2 Week End M 1 4 05 Stop 2 Week End M 1 1 Abilita Crono M 1 1 01 M 1 M 1 2 01 Program an 2 c M 1 2 03 M 1 2 04 M 1 2 05 M 1 3 01 M 1 3 02 ON OFF ojo n ET ON OFF Men 02 M Nodo Sian ty Tipo Pellet Carico iniziale coclea 2 N OFF 9 9 ON OFF Regolazioni Utente egolazione Pellet egolazione Pellet Menu 05 menu per il tecnico Regolazioni Installatore M 1309 13 12 _ 1 15__ ISC M 321 M13 24 i M 1330 M1 3 33 M1 3 36 Ll M1337 re i __ 1 4 05 Od A AAA nn 04 menu per il tecnico Stato Caldaia 25 DOMUSFIRE C29 C35 C39 4 6 1 Menu 01 Set crono Permette di abilitare e disabilitare tutte le funzioni del cronotermostato con la selezione ON si attiva la funzione e viene visualizzata il relativo segmento led Quando viene inserita la programmazione Giornaliera Settimanale o Week End nella parte superi
122. consigliato l inserimento di una VALVOLA TERMOSTATICA AUTOMATICA disponibile su richiesta nell impianto al fine di migliorare l efficienza della combustione e la durata della caldaia nonch la riduzione di condense dei fumi nei condotti fumari con quantit minori di incrostazioni e catrami Prima di allacciare la caldaia al circuito idraulico prevedere un accurato lavaggio di tutte le tubazioni dell impianto per rimuovere eventuali residui o scarti di lavorazione che possono compromettere il regolare funzionamento dei componenti di controllo regolazione e sicurezza dello stesso impianto Durante il trasporto della caldaia si possono verificare allentamenti e o cedimenti delle ghiere e delle relative guarnizioni di tenuta dell impianto idraulico causando delle perdite d acqua durante il A funzionamento a tale scopo si raccomanda sia durante il caricamento d acqua sia dopo le prime ore di funzionamento di controllare il serraggio delle ghiere di attacco circolatori e termo camera nonch di scaricare i residui di aria rimasti nell impianto 2 9 1 Carico acqua impianto Ultimati i collegamenti idraulici si pu procedere al CARICAMENTO dell apparecchio e del relativo impianto aprire tutte le valvole di sfiato aria dei radiatori collettori caldaia e impianto aprire gradualmente il rubinetto di carico acqua verificando che le valvole di sfiato funzionino regolarmente procedere lentamente al caricamento dell acqua nell impianto
123. controller available on request must be installed In solid fuel boilers to avoid the return of cold water in the heating chamber during the heating phase it is advisable to install an AUTOMATIC THERMOSTATIC VALVE available on request in the system to improve combustion efficiency and boiler life and also reduce the condensation of fumes in the flueways with less deposits and tars Before connecting the boiler to the water circuit thoroughly clean all system pipes to remove any residuals or machining residuals that could compromise the proper operation of the adjustment control and safety components During boiler transport the rings and respective seals in the water system may come loose and or break causing water leaks during operation therefore make sure to check the tightening of the circulating pump and heating chamber connection rings and vent the residual air during water filling and after the first hours of operation 2 9 1 System water filling After carrying out the plumbing connections it is possible to FILL the unit and system open all the air vent valves of the radiators manifolds boiler and system open the water filling cock gradually making sure the vent valves work properly fill the system slowly to allow proper and complete evacuation of the air from the vent bringing the circuit under pressure for a closed vessel system from 1 1 to 1 5 bar when finished close the filling cock and make sure all vent
124. cted externally by a grille must be provided near the boiler or by connection directly to the outside with a suitable pipe of inside diameter 60mm and max length 1 5 m suitably protected at the end gt or through the room adjacent to that of installation provided the air is free to flow through permanent openings communicating with the outside meeting the requirements described above The adjacent room must not be subject to a lower pressure than the outside environment due to the draught effect created by the presence of other possible units or suction devices The adjacent room can not be used as a car garage for storing combustible material or for activities with fire risk The boiler air inlet connection or intake is located at the back and is round and 60 mm in diameter 2 4 Fume exhaust Fumes can be exhausted through a connection to an approved flue local national and European regulations Only certified pipes and connections with adequate seals guaranteeing their tightness must be used Flexible metal tubes or fibre cement pipes are prohibited In case of fire turn the boiler off promptly call the fire department and avoid continual attempts to extinguish it N The installer must check the efficiency and state of the flue and its conformity with the 44 DOMUSFIRE C29 C35 C39 COLA 2 4 1 Types of installations Listed below are definitions and requirements for correct installation of an exhaust flue in accordanc
125. ctividades con peligro de incendio La conexi n de aspiraci n o toma de aire de la caldera se encuentra en la parte posterior y tiene secci n circular con di metro de 60 mm 2 4 Salida de los humos de combusti n La salida de humos se debe hacer mediante conexi n a una chimenea de acuerdo con las normas normas y disposiciones locales nacionales y europeas Utilizar solo tubos y empalmes certificados con juntas adecuadas que aseguren la estanqueidad Est prohibido utilizar tubos met licos flexibles o de fibrocemento En caso de incendio apague la caldera desconecte la alimentaci n el ctrica y llame inmediatamente a los bomberos si no consigue extinguirlo al primer intento N Se recomienda al instalador verificar la eficiencia y el estado de la chimenea y la conformidad con las 138 DOMUSFIRE C29 C35 C39 COLA 2 4 1 Tipos de instalaciones A continuaci n se detallan las definiciones y los requisitos para realizar la salida de humos con arreglo a la norma italiana UNI 10683 Si D CHIMENEA conducto vertical que recoge y expulsa a una altura adecuada LS del suelo los productos de combusti n de un solo aparato o en casos x 2 permitidos de mas de uno US Requisitos t cnicos de la CHIMENEA Debe ser estanca a los productos gig de combustion y contar con el aislamiento necesario en funci n de la A lm utilizaci n adi ser lo m s vertical posible con una desviaci n
126. cuit activation d uM ALARM gt 4 3 Lighting 4 3 1 Check before lighting Before lighting the boiler make sure to have read and understood the information given in the manual the hopper must be filled with pellets the combustion chamber must be clean the brazier must be completely free cleaned of any combustion residuals and correctly fitted in the brazier holder check hermetic closing of the ash box and fire door check the connection of the power cable and switching to ON 1 of the switch located on the back of the boiler check opening of the delivery and return shutoff valves as well as the water circuit pressure At first startup remove all the components that could burn instructions label from the boiler firebox IN Any lighting done after long idle periods requires the removal of any residual pellets that have remained inside the hopper in being damp fuel no longer suitable for combustion and complete cleaning of the combustion chamber 52 DOMUSFIRE C29 C35 C39 COLA 4 3 2 Startup stage To light the boiler press the button P4 for 3 seconds the message START will appear on the display This stage is automatic and managed entirely by the electronic controller without the possibility of changing the parameters Alternatively the boiler can be lit by pressing the buttons P4 and P5 together for 3 seconds The message AWAITING REQUEST appears on the display With this mode the boiler swi
127. culite refrattario parti estetiche in metallo o ceramica maiolica braciere deviatori fiamma fumo ecc Eventuali difetti estetici su ceramiche maioliche o su qualsiasi parte a vista in metallo vanno rilevati pena di decadenza al momento della consegna le segnalazioni effettuate successivamente a tale data sono escluse dalla garanzia Modalit per far valere la presente Garanzia In caso di guasto il Cliente deve richiedere entro il termine di decadenza di 30 giomi l intervento del Centro Assistenza di zona autorizzato Inominativi dei Centri Assistenza autorizzati sono reperibili attraverso il sito internet o il numero telefonico dell azienda Produttrice I costi di intervento sono a carico dell azienda Produttrice fatte salve le esclusioni previste e riportate nella presente Garanzia Gli interventi in garanzia non modificano la data di decorrenza o la durata della stessa Esclusioni Sono escluse dalla presente Garanzia i guasti e gli eventuali danni causati da trasporto non effettuato a cura dell azienda Produttrice inosservanza delle istruzioni e delle avvertenze previste dall azienda Produttrice e riportate sui manuali d uso e manutenzione a corredo del prodotto errata installazione o inosservanza delle prescrizioni di installazione previste dall azienda Produttrice e riportate sui manuali d uso e manutenzione a corredo del prodotto inosservanza di norme e o disposizioni previste da leggi e o regolamenti vigenti
128. d Reduced output consumo di pellet pu variare dal tipo di pellet utilizzato Pellet consumption can vary according to the type of pellets used 39 DOMUSFIRE C29 C35 C39 COLA Overall dimensions Pellet boiler model DOMUSFIRE C29 DOMUSFIRE C35 DOMUSFIRE C39 KEY A Power cable connection 8 Overpressure water discharge 1 2 F 3 bar Heating system return 1 D Combustion air inlet c 60mm Water supply connection 1 2 F D System water drain S System water drain Connection delivery without pump 1 M D Delivery pump inspection O Heating system delivery 1 M D Fume exhaust pipe connection 100mm M Pressure temperature gauge N Control panel model EVO Door to access fire door and ash box P Adjustable feet G Pellet hopper door Turbulator shaker knob KEY OPTIONAL ELEMENTS S OPT DHW delivery pump inspection T OPT DHW return 3 4 pump U OPT DHW delivery 3 4 M pump V DHW overpressure water discharge 1 2 F 6 bar W OPT DHW return 1 2 M exchanger Z OPT DHW delivery 1 2 M exchanger ACCESSORIES ON REQUEST DHW ASSEMBLY WITH PUMP AND EXCHANGER INSIDE BOILER DHW ASSEMBLY WITH PUMP INSIDE BOILER SUPPLEMENTARY PELLET HOPPER CAPACITY approx 250 kg 40 DOMUSFIRE C29 C35 C39 COLA Fire door opening closing Boiler model DOMUSFIRE To open the outer door pull o
129. d oder Decken D cher aus entflammbarem oder w rmeempfindlichen Material mit Schutzplatten aus isolierendem Material gesch tzt werden m ssen Kontrollieren ob im technischen Installationsraum hinter und neben dem Kessel gen gend Freir ume vorhanden sind um die Wartung und Reinigung des Ger ts der Abgasleitungen und des Schornsteinrohres zu gestatten Au erdem sicherstellen dass der Pelletbeh lter zum Einf llen des Brennstoffs leicht zug nglich ist Die f r die Wartung und zur Sicherheit erforderlichen Mindestabst nde m ssen der nachstehenden Tabelle entsprechen OPTIONALER ZUSATZLICHER BEHALTER A 500 mm B 500 mm C 500 mm D 1000 mm B 1450 mm T 700 mm 106 DOMUSFIRE C29 C35 C39 COLA Lufteinlass an der Wand T St ck mit Inspektionsdeckel Der Kessel wird mit 4 verstellbaren F en geliefert um die Aufstellung auf nicht perfekt ebenen Fu b den zu erleichtern Um die H he eines Stellfu es zu verstellen den Kessel so weit wie erforderlich neigen und den betreffenden Stellfu drehen 2 3 Lufteinlass Die f r den ordnungsgem en Betrieb erforderliche Verbrennungsluft muss dem Kessel ber die Au enluftansaug ffnungen zugef hrt werden und zwar gt entweder durch Anbringung einer mindestens 100 cm gro en und au en mit einem entsprechenden Gitter gesch tzten Ansaug ffnung an einer Au enwand in Kesseln he deren Position so zu w hlen ist dass sie nicht verdeckt
130. da Al termine dell operazione assicurarsi che i turbo latori siano in posizione di riposo sul livello pi basso Pomelli di comando DX SX del dispositivo scuoti turbolatori in posizione bassa di funzionamento caldaia 30 DOMUSFIRE C29 C35 C39 6 MANUTENZIONE 6 1 Premessa COLA Gli interventi sui componenti interni della caldaia devono essere effettuati da personale qualificato rivolgendosi al centro assistenza autorizzato piu vicino Prima di ogni intervento accertarsi che sia disinserita la spina dell alimentazione elettrica e la caldaia sia completamente fredda 6 2 Smontaggio rivestimento caldaia Legenda 1 Sportello pellet 2 Coperchi intermedi centrali 3 Pannello laterale 4 Coperchio anteriore 5 Porta esterna isolata 6 Pannello posteriore 6 3 Componenti interni della caldaia 3 UE H gt PEN BAN x Xe NE de NN A Ce N 5 Legenda 1 Pomello con asta filettata 2 Perno prolunga scuoti turbolatori 3 Dado serraggio bussola 4 Bussola di scorrimento perno 5 Coperchio esterno 6 Protezione termica superiore 7 Protezione intermedia 8 Protezione superiore vermiculite 9 Protezione laterale vermiculite 10 Protezione termica esterna camera 11 Coperchio sostegno protezioni 12 Sostegno turbo latori 13 Turbolatori 14 Porta fuoco 15 Valvola di sicurezza
131. da die Heiz und die Warmwasseranlage bedient werden kann Wenn sich der Kessel in der Phase WARTEN AUF BEDARF befindet wird er automatisch eingeschaltet und in BETRIEB versetzt und sobald das Wasser in der Heizkammer die Betriebstemperatur erreicht hat wird die Zuleitung von Wasser zum Pufferspeicher aktiviert Wenn der SOLLWERT der Temperatur im Pufferspeicher erreicht ist schaltet der Kessel auf WARTEN AUF BEDARF die Funktion STANDBY muss unbedingt auf ON gestellt werden siehe Abschn 4 6 4 Wenn der Kessel AUSGESCHALTET ist wird er nicht eingeschaltet und liefert kein Warmwasser 4 14 Ausschalten Zum Ausschalten des Kessels einfach die Taste P4 etwa 2 Sekunden lang dr cken Die F rderschnecke wird sofort angehalten das Saugzuggebl se schaltet auf eine hohe Drehzahl und auf dem Display erscheint die Meldung ENDREINIGUNG Temperatur H20 Boiler oder Am Ende des Vorgangs erscheint im Dialogfenster auf dem Display die Meldung AUS W hrend der Abschaltphase kann der Kessel nicht wieder eingeschaltet werden bevor die Abgastemperatur f r eine vorgegebene Dauer unter einen ebenfalls vorgegebenen Wert gesunken ist Im Dialogfenster erscheint die Meldung ABK HLEN BITTE WARTEN Wassert 118 DOMUSFIRE C29 C35 C39 COLA 4 15 Menu Durch Dr cken der Taste P3 SET ffnet sich das Mend dieses ist in verschiedene Optionen und Ebenen unterteilt Uber die die Einstellungen der elektronische
132. del agua 4 4 2 Reencendido desde STAND BY 4 4 3 Limpieza del brasero 4 4 4 Agua caliente sanitaria con intercambiador r pido 4 4 5 Agua caliente sanitaria con acumulador 4 4 6 Sistema con dep sito de inercia acumulador de calor 4 5 Apagado 130 COLA 4 10 Men s 4 6 1 men 01 Ajustes crono 4 6 2 men 02 Configuraci n de usuario 4 6 3 men 03 Ajustes de usuario 4 6 4 men 04 Estado de la caldera 4 6 5 men 05 Ajustes del instalador 4 7 Termostato cronotermostato externo 4 8 Per odo de inactividad final de temporada 5 LIMPIEZA DE LA CALDERA 5 1 Limpieza de brasero y portabrasero 5 2 Limpieza del cenicero 5 3 Limpieza del extractor de humos y de la c mara de combusti n 5 4 Limpieza del deb metro 5 5 Limpieza del tubo de humos chimenea 5 6 Limpieza de los intercambiadores con el sacudidor de turbuladores 6 MANTENIMIENTO 6 1 Introducci n 6 2 Desmontaje del revestimiento de la caldera 6 3 Componentes internos de la caldera 6 4 Componentes el ctricos 6 5 Componentes hidr ulicos de serie 7 LOCALIZACI N DE AVER AS 7 1 Gesti n de las alarmas 8 ANEXOS 8 1 Informaci n sobre el marcado CE DOMUSFIRE C29 C35 C39 COLA 1 ADVERTENCIAS GENERALES 1 1 Introducci n Estimado Cliente En primer lugar deseamos agradecerle la confianza que nos ha demostrado al adquirir uno de nuestros productos Le invitamos a leer y seguir atentamente los consejos dados en este manual de instalaci n uso y m
133. del combustibile sacchi di pellet devono essere riposti lontano dalla caldaia almeno 1 5 m i Si raccomanda di controllare il livello del pellet nel serbatoio per evitare che la fiamma si spenga per 4 4 1 Modifica impostazione temperatura acqua Per modificare la temperatura acqua necessario entrare nel MENU 03 con la pressione sul pulsante P3 successivamente sui pulsanti P1 e P2 per accedere al MENU M 3 6 e per impostare il valore di temperatura desiderato Quando la temperatura acqua ha raggiunto il valore impostato AP 2 oppure la temperatura fumi ha raggiunto il valore massimo settato ECH SEE E P la potenza viene automaticamente portata al valore minimo n condizione di MODULAZIONE A ALAUA Quando la temperatura dei fumi arriva ad un valore massimo impostato compare sul pannello di controllo il messaggio MODULA F e la stufa attiva la procedura di modulazione della fiamma senza alcun intervento dell utente mentre se la temperatura supera i 280 C appare l allarme AL3 HOT FUMI e la caldaia attiva la procedura di spegnimento 4 4 2 Riavvio da STAND BY Con l attivazione della funzione STAND BY e del relativo termostato da ambiente o da Puffer la caldaia al termine dello spegnimento si pone in condizione di raffreddamento portando la velocit dell estrattore fumi al valore impostato per la pulizia braciere La riaccensione avviene non appena la temperatura acqua ha raggiunto il v
134. dell interruttore A Il cavo di alimentazione non deve mai toccare il tubo di scarico della stufa 14 DOMUSFIRE C29 C35 C39 COLA 2 7 Schema elettrico VLISISQNVO A AA 55v OIOLVEYAS V31909 INI Y31909 d VIddOd OSIH d 051 d i fe IT II IT IT II e sI Di SS OY 1311830 I TITI III III II IT SCH 1173N09 SLIOZITABSZIO H YNI SNI 9NI SN BNI ZNI SNI ARERR OOOO PRESSIONE H20 al SONDAAMB EXT rermpas oi SONA FUMIE SONDA H20 BOILER PUFFER LIVELLO PELLET CALDAIA LIVELLO PELLET x SERBATOIO DOMUSFIRE C29 C35 C39 15 COLA 2 8 Schema elettrico per impianto a zone Prima di installare la caldaia nell abitazione verificare la tipologia dell impianto di riscaldamento se sono presenti pi zone e necessario inserire un apposita centralina elettronica per circuiti multizona disponibile come optional Questo al fine di evitare il surriscaldamento dell apparecchio per la possibile chiusura contemporanea delle val
135. des fum es de combustion l int rieur de la chambre et des conduits d vacuation les fum es seront vacu es travers des soupapes de s ret install es au dessus du cendrier Durant le fonctionnement normal ces soupapes restent ferm es sous leur propre poids et sous l effet de la d pression de la chambre de combustion de sorte garantir l tanch it contre l vacuation ventuelle des fum es A S assurer r guli rement que le dispositif est ferm qu il est en bon tat et qu il fonctionne correctement 3 4 Surchauffe thermostats de s curit Sur la paroi basse du r servoir et plus pr cis ment sur le convoyeur d alimentation des granul s et dans la partie haute de la chambre de combustion sont situ es deux sondes de temp rature reli es un thermostat de s curit qui bloquent automatiquement l alimentation des granul s en cas de surchauffe Dans ce cas l extracteur et ou les ventilateurs continuent a fonctionner pour refroidir plus rapidement l appareil L anomalie est affich e sur le tableau de commande par le message AL 7 S CURIT THERMIQUE En cas d intervention proc der de la facon suivante Laisser refroidir la chaudi re pendant au moins 45 minutes gt R armer le thermostat en appuyant sur le bouton c t de l interrupteur derri re la chaudi re figure ci contre apr s avoir t la protection et plus pr cis ment T1 thermostat temp rature eau chambre de combustion T2 th
136. di re a granul s mod DOMUSFIRE C29 DOMUSFIRE C35 DOMUSFIRE C39 LEGENDE A Branchement du cable lectrique Evacuation d eau en surpression 1 2 femelle 3 bars Retour circuit chauffage 1 D Aspiration d air comburant 60mm Raccordement r seau eau de ville 1 2 F E Evacuation eau installation vacuation eau installation d part sans pompe 1 Inspection pompe d part O D part circuit chauffage 1 M D Raccordement tuyau d expulsion des fum es 100 mm M Thermomanom tre N Tableau de commande mod EVO Porte ouvrante pour acc s porte foyer et cendrier P Pieds r glables G Volet du r servoir granul s amp Bouton de secouage des turbulateurs L GENDE L MENTS EN OPTION S Inspection pompe d part sanitaire OPT T Retour eau sanitaire OPT 3 4 pompe U D part eau sanitaire OPT 3 4 M pompe V Evacuation d eau sanitaire en surpression 1 2 F 6 bars W Retour eau sanitaire OPT 1 2 M changeur Z D part eau sanitaire OPT 1 2 M changeur ACCESSOIRES SUR DEMANDE GROUPE SANITAIRE AVEC POMPE ET CHANGEUR INT RIEUR CHAUDIERE GROUPE SANITAIRE AVEC POMPE INTERIEUR CHAUDI RE RESERVOIR A GRANULES SUPPL CONTEN env 250 kg EY 71 DOMUSFIRE C29 C35 C39 COLA Ouverture fermeture de la porte du foyer de la chaudi re mod DOMUSFIRE Pour ouvri
137. di re en marche en respectant la proc dure normale d crite dans ce manuel Chaque signalisation d alarme comporte l extinction imm diate de la chaudi re Les alarmes visualis es sur le tableau de commande sont les suivantes COLA ALARMES MESSAGES Signalisation Anomalie Causes probables Solutions Mettre la chaudi re en position OFF en appuyant sur la touche P4 AL 1 Le courant n arrive pas la 4 repeter a procedure COUPURE DE La chaudi re ne s allume pas chaudi re pendant la phase en da COURANT lage r tablissement du fonctionnement normal doivent tre effectu es par un centre d assistance AL 2 Cette alarme se d clenche en cas de dysfonctionnement de la i D autres op rations de SONDE sonde d d tection de la Fe Sg i r tablissement du fonctionnement THERMIQUE temp rature des fum es normal doivent tre effectu es par DES FUMEES d extinction est un centre d assistance activ e Cette alarme se d clenche dans Chargement excessif de R gler l alimentation des AL 3 le cas ou la aa rel ve une granul s m a 2 temp rature des fum es an D autres op rations de FU MEES sup rieure a 280 C ere r tablissement du fonctionnement BRULANTES ja proc dure d extinction est normal doivent tre effectu es par activ e un centre d assistance Cette lame ss d clenche E de Les op rations de r tablissem
138. diciones de suministro transporte y almacenaje La caldera se suministra envuelta en plastico y embalada sobre un palet con jaula de madera Antes de la entrega todos los equipos se prueban en la linea de montaje de la fabrica La caldera se puede transportar con su embalaje en una carretilla elevadora introduciendo las horquillas de longitud adecuada en las cavidades del palet de madera Compruebe que los dispositivos utilizados para la elevaci n y el transporte soporten el peso de la caldera indicado en la placa de identificaci n en el presente manual No pase la carga por sitios donde la ca da pueda representar un peligro Durante el transporte y el almacenaje evite la exposici n a lluvia o humedad persistente La caldera debe desplazarse en posici n vertical con la base apoyada en la carretilla elevadora A Utilice herramientas apropiadas para quitar las tablas u otras partes de madera que formen el embalaje de la caldera Deseche el embalaje de acuerdo con las normas y no lo deje al alcance de los ni os ni de personas con discapacidades 2 2 Lugar de instalaci n emplazamiento y prevenci n de incendios Una vez preparadas las conexiones hidr ulica y el ctrica por parte de un t cnico autorizado abra el embalaje retire la caldera del palet y ub quela en el lugar elegido respetando las indicaciones del presente manual Se recomienda apoyar la caldera en el suelo en el lugar de instalaci n con mucho cuidado y evita
139. do es importante no sobrecalentar la caldera sino aumentar gradualmente la temperatura programando temperaturas de funcionamiento bajas vea el apartado de programaci n de la temperatura Durante el encendido el funcionamiento y el apagado la caldera puede crujir a causa de las dilataciones y contracciones t rmicas 4 2 Descripci n del panel de mandos El panel est formado por una pantalla LCD retroiluminada la tecla de encendido y apagado P4 la tecla de funci n SET MENU P3 las cuatro teclas de men P1 P2 P5 y P6 y siete s mbolos que indican el estado de funcionamiento de la estufa Indicadores de estado pantalla Pantalla LCD retroiluminada Teclas de ajuste Teclas de sche y ajuste y selecci n ie A Tecla de encendido y gt apagado Receptor de IR El panel permite encender y apagar la caldera regularla durante el funcionamiento y ajustar los programas de gesti n y mantenimiento En la pantalla se visualizan informaciones sobre el estado de funcionamiento de la caldera Para acceder a los men s proceda del siguiente modo Pulse la tecla SET Pulse las teclas P5 y P6 para recorrer los men s Presione una de las teclas de aumento disminuci n P1 o P2 para ajustar el par metro deseado Pulse la tecla SET P3 para confirmar el ajuste 145 DOMUSFIRE C29 C35 C39 COLA A trav s de los menus se pueden obtener los diversos tipos de visualizaci
140. do 4 2 Ti H Con el submen PROGRAM D A es posible habilitar deshabilitar y ajustar las funciones del cronotermostato diario Se pueden ajustar dos fases de funcionamiento delimitadas por los 4 36 horarios fijados de acuerdo con la tabla siguiente donde la opci n OFF n E g fe indica al reloj que ignore el mando 5 A ARE selecci n significado valores posibles START1 hora de activaci n hora OFF d STOP1 hora de desactivaci n hora OFF START2 hora de activaci n hora OFF STOP2 hora de desactivaci n hora OFF Ventana de di logo Con el submen PROGRAM SEMANA es posible habilitar deshabilitar y ajustar las funciones del cronotermostato semanal El control semanal se realiza con cuatro programas independientes cuyo efecto final es la combinaci n de las cuatro programaciones El programador semanal se puede activar y desactivar Si se selecciona OFF en el campo horario el reloj ignora el mando correspondiente SERRE PROS de activaci n y desactivaci n para el mismo d a en distintos programas Ventana de di logo q Realice la programaci n con cuidado evitando superponer las horas Con el submenu PROGRAM FIN SEMAN es posible habilitar deshabilitar y ajustar las funciones del cronotermostato para el fin de semana s bado y domingo 143 Antes de activar la programaci n para el FIN DE SEMANA se debe desactivar la programaci n semanal R
141. dor Cuando el acumulador alcanza la temperatura de consigna la caldera env a el calor residual al sistema de calefacci n durante dos minutos tras lo cual si no hay m s demandas se dispone en ESPERA DEMANDA o en MODULACI N seg n los ajustes apartado 4 6 4 Si la caldera est en modo APAGADO no se enciende y el servicio no se produce 4 4 6 Sistema con dep sito de inercia acumulador de calor Esta configuraci n exige el uso de un termostato exterior para medir la temperatura del agua contenida en el dep sito de inercia Cuando la temperatura se hace inferior al ajuste del termostato exterior en la pantalla de la caldera aparece el mensaje AGUA DEP INERCIA o AGUA ACUMUL y se encienden respectivamente el s mbolo del grifo y del radiador porque el equipo puede abastecer los sistemas de calefacci n y agua sanitaria Si la caldera est en modo ESPERA DEMANDA se enciende autom ticamente se dispone en TRABAJO y cuando el agua de la c mara t rmica llega a la temperatura establecida se activa el env o al dep sito de inercia Cuando el agua del dep sito de inercia llega a la temperatura de consigna la caldera se dispone en ESPERA DEMANDA se recomienda poner la funci n STAND BY en ON apartado 4 6 4 Si la caldera est en modo APAGADO no se enciende y el servicio no se produce 4 17 Apagado Para apagar la caldera es suficiente presionar la tecla P4 durante 2 segundos El sinf n se para de inmediato el extractor de
142. duct family standard Standard CEI EN 61000 3 2 Limits for harmonic current emissions Input current lt 16 A per phase Standard CEI EN 61000 3 3 Limitation of voltage fluctuations and flicker in low voltage supply systems for equipment with nominal current lt 16 A Standard CEI EN 62233 Measuring methods for electromagnetic fields of electrical household appliances and similar with reference to human exposure Standards DIN plus 51731 UNI EN14961 2 O Norm M 7135 Standards regarding the specifications and classification of pellets 1 8 Data plate The data plate is visible on the inside of the pellet hopper door or on the back of the boiler It gives the following data On it are listed all the technical data in the table par 1 4 1 9 Boiler decommissioning When the unit is no longer to be used disconnect it from the power supply and empty all pellets from the hopper For disposal the boiler must be sealed inside strong packing contact the local authority in charge of such operations in order to proceed according to the current local regulations or take it to the dealer when purchasing a similar new unit Under Article 13 Leg Decree No 151 of 25 July 2005 implementing Directive 2002 96 EC of 23 February 2003 on Waste Electrical and Electronic Equipment and procedures relating to measures aimed at preventing the production of waste electrical and electronic equipment called WEEE promoting reuse recycling and other forms of reco
143. e Le nettoyage comprend l aspiration et l limination de r sidus de combustion dans tous les tron ons verticaux et horizontaux ainsi que dans les coudes de l appareil au conduit de fum e Il est galement conseill de nettoyer le conduit de fum e une fois par an afin de garantir une parfaite vacuation des fum es 5 6 Nettoyage des changeurs avec le dispositif de secouage des turbulateurs Le nettoyage des tubes de fum e dans la chambre de combustion doit se faire au moins une fois tous les 2 3 jours au moyen des deux boutons en accomplissant des mouvements de va et vient Cette op ration doit tre effectu e lorsque la chaudi re est teinte et froide Une fois l op ration termin e s assurer que les turbulateurs sont en position de repos sur le niveau plus bas Boutons de commande droit gauche du secouage des turbulateurs en position basse de fonctionnement de la chaudi re 92 DOMUSFIRE C29 C35 C39 COLA 6 ENTRETIEN 6 1 Introduction Les interventions sur les composants de la chaudi re doivent tre effectu es par un professionnel qualifi en s adressant au centre d assistance le plus proche Avant toute intervention s assurer que la fiche est d branch e de l alimentation lectrique et que la chaudi re est compl tement froide 6 2 D montage de l habillage de la chaudi re L gende 1 Couvercle de r servoir granul s 2 Couvercles interm diaires centraux 3 Flanc panne
144. e dopo aver disattivato la programmazione settimanale Al fine di evitare operazioni di avvio e spegnimento non A voluti attivare un solo programma per volta Disattivare il programma giornaliero se si desidera impiegare quello settimanale con questa impostazione opportuno disattivare il programma week end 26 Iz Hb LI ER Livello di menu Finestra di dialogo Finestra di dialogo Livello di menu 435 Ta I 4H 03 min EEH End DOMUSFIRE C29 C35 C39 COLA 4 6 2 Menu 02 Regolazioni utente Con tale menu possibile eseguire una serie di settaggi come segue Set orologio Prima di operare con la caldaia necessario impostare l ora e la data corrente affinch si abbia un riferimento per le possibili programmazioni sul crono Il controllo elettronico provvisto di batteria al litio mod CR2032 da 3 Volt che permette all orologio interno un autonomia superiore ai 4 5 anni qualora a caldaia spenta l orologio non mantiene l orario o alla riaccensione viene visualizzato una serie di zeri necessario procedere alla sostituzione chiamando un centro di assistenza autorizzato Modo Stand by Attivando tale funzione la caldaia si spegne automaticamente dopo che la temperatura dell acqua rimasta superiore al valore di SET per un tempo prefissato La successiva riaccensione in automatico sar possibile solamente quando la temperatura dell acqua scende al di sotto di un valore pre
145. e au erordentliche Wartung durch Fachpersonal an das eine vollst ndige Reinigung und die R cksetzung der Meldung vornimmt A Durch St Be oder gewaltsames Vorgehen kann das Saugzuggebl se besch digt und dessen lauter Betriebverursacht werden deshalb sollte mit diesem Vorgang unbedingt qualifiziertes Fachpersonal betraut werden 5 4 Reinigung des Luftmassenmessers In das Rohr ist ein Luftmassenmesser eingebaut Messgerat der Verbrennungsluftzufuhr der regelmaBig d h alle 3 4 Monate mit geeigneten Mitteln Druckluftstrahl oder geeignete Pinsel innen gereinigt werden muss 5 5 Reinigung Abgasstutzen Schornsteinrohr Der Abgasstutzen muss mindestens einmal jahrlich oder bei Bedarf gereinigt werden Die Reinigung umfasst das Absaugen und Entfernen der R ckst nde in allen senkrechten und waagerechten Rohrabschnitten sowie in den Rohrkr mmern vom Ger t zum Schornsteinrohr Einmal im Jahr sollte auch das Schornsteinrohr gereinigt werden um eine korrekte und sichere Rauchabf hrung sicherzustellen 5 6 Reinigung der W rmetauscher mit dem Turbulatorenr ttler Die Rauchz ge in der Heizkammer sind mindestens alle 2 3 Tage zu reinigen Dazu mehrmals die Kn ufe von unten nach oben und umgekehrt bewegen Den Vorgang am ausgeschalteten und kalten Kessel durchf hren Am Ende des Vorgangs sicherstellen dass sich die Tubulatoren in Ruhestellung in unterster Position befinden Rechter und linker Knauf des Turbulatoren
146. e L6schversuche zu unternehmen 107 DOMUSFIRE C29 C35 C39 COLA 2 4 1 Installationsarten Nachstehend werden die Vorgaben und Anforderungen aufgefuhrt die fur die korrekte Installation eines Rauchabzugs gem erf llt werden m ssen SCHORNSTEIN Aufw rtsf hrende bauliche Vorrichtung zum Sammeln und zur Abf hrung der Verbrennungsprodukte einer bzw in den zul ssigen Sa 79 Fallen mehrerer Feuerst tten in einer angemessenen H he vom Boden E We D Technische Anforderungen des SCHORNSTEINS abgasdicht mit vom L Einsatz abhangiger Isolierung und Warmedammung Schomsteinr___ Uberwiegend senkrechter Verlauf mit Achsabweichungen lt 45 ausreichender Abstand entflammbarem Material mit Luftspalt oder Rauchrohr isolierendem Zwischenraum P vorzugsweise mit rundem konstantem freiem und unabh ngigem bester Querschnitt F e Kammer der Schornstein sollte eine inspizierbare Kammer zum Auffangen fester d Pigi Stoffe e smi 100 cme und eventuell sich bildendem Kondensat besitzen die unter dem Eingan Mindestabstand 0 2 m des Abgaskanals angebracht ist ABGASKANAL oder RAUCHROHR Leitung oder Verbindungsst ck zwischen Feuerst tte und Schornstein f r die Abf hrung der Verbrennungsprodukte Technische Anforderungen an den ABGASKANAL Der Abgaskanal darf keine R ume durchqueren in denen die Installation von Heizger ten verboten ist die
147. e comprometiere la regolare alimentazione pertanto si consiglia prima della ricarica pellet di rimuovere la polvere dove presente Evitare il caricamento nel serbatoio di combustibili non conformi Evitare il caricamento nel serbatoio di corpi estranei quali contenitori scatole sacchetti metalli etc L utilizzo di pellet scadenti e non conforme danneggia e compromette il funzionamento dell apparecchio facendo decadere la validit della garanzia con esclusione della responsabilit da parte del costruttore 1 6 Accessori in dotazione La dotazione comprensiva di Cavo alimentazione elettrica Manuale d installazione uso e manutenzione Chiave di apertura chiusura 10 DOMUSFIRE C29 C35 C39 COLA 1 7 Riferimenti normativi Norma UNI 10683 2012 Requisiti di installazione dei generatori di calore alimentati a legna o altri biocombustibili solidi Norma UNI EN14785 2006 Requisiti di progettazione fabbricazione costruzione sicurezza e prestazioni istruzioni marcature unitamente ai relativi metodi di prova per le omologazioni degli apparecchi funzionanti a pellet Norma UNI EN303 5 2004 Terminologia requisiti prove e marcatura relative a Caldaie per combustibili solidi con alimentazione manuale e automatica Norma UNI 10412 2 2009 Requisiti di sicurezza per impianti con apparecchi per il riscaldamento di tipo domestico alimentati a dei generatori di calore alimentati a combustibi
148. e herm tique de la porte de foyer et du cendrier v rifier le branchement du cordon lectrique et la commutation ON 1 de l interrupteur mont l arri re de la chaudi re v rifier l ouverture des vannes d arr t d part et retour ainsi que la pression du circuit hydraulique A la premi re mise en service retirer du foyer tout ce qui pourrait br ler instructions tiquette Contact externe Chrono Vis sans fin R sistance lectrique Extracteur de fum es Activation du circuit SANITAIRE Activation du circuit CHAUFFAGE ALARME Les allumages ventuels apr s de longues p riodes d inactivit de la chaudi re ne doivent s effectuer qu apr s avoir enlev les r sidus de granul s rest s dans le fond du r servoir car ils ne s enflammeraient plus trop humides et apr s un nettoyage complet de la chambre de combustion 83 DOMUSFIRE C29 C35 C39 COLA 4 3 2 Mise en marche Pour allumer la chaudi re appuyer 3 secondes sur le bouton P4 l cran affichera l indication START Cette phase est automatique et est compl tement g r e par l lectronique de commande Il n est pas possible ici d intervenir sur les param tres Par contre il est possible d allumer la chaudi re en appuyant simultan ment 3 secondes sur les boutons P4 et P5 L cran affiche DEMANDE D ATTENTE Cette modalit met la chaudi re en tat d attente et proc de la phase d allumage uniquement si la dem
149. e ke ni O j Para evitar encendidos y apagados indeseados se debe activar un 5 E np A solo programa por vez Desactive el programa diario si desea utilizar el semanal En este Fin 5 5 nA caso tambi n se aconseja desactivar el programa de fin de semana 151 DOMUSFIRE C29 C35 C39 COLA 4 6 2 Menu 02 Configuracion de usuario Este menu da acceso a las siguientes configuraciones Ajuste reloj Antes de utilizar la caldera se deben indicar la fecha y hora actuales para que sirvan de referencia para el posible funcionamiento con crono El control electr nico funciona con una bater a de litio mod CR2032 de 3 V que asegura al reloj interno una autonom a superior a 4 5 a os Si con la caldera apagada el reloj no mantiene el horario o al reencendido aparece una serie de ceros llame a un centro de asistencia autorizado para cambiar la bater a Modo stand by Si se activa esta funci n la caldera se apaga autom ticamente cuando la temperatura del agua permanece por encima del valor de consigna SET durante un tiempo prefijado El reencendido es autom tico cuando la temperatura del agua se hace inferior a la consigna introducida en la tabla de par metros valor de f brica 2 C Los mandos impartidos desde el panel de la caldera son prioritarios respecto a la programaci n Si este par metro se ajusta en OFF la caldera no utiliza el modo STAND BY y funciona normalmente activando la funci n MODULACI N cuando la temperatura
150. e sure the boiler is unplugged and cold before carrying out any work on it 6 2 Removing the boiler cladding Key 1 Pellet hopper door 2 Central middle covers 3 Side panel 4 Front cover 5 Insulated outer door 6 Rear panel 6 3 Boiler internal parts Key 1 Knob with threaded rod 2 Turbulator shaker device extension pin 3 Bush locking nut 4 Pin sliding bush 5 Outer cover 6 Upper thermal protection 7 Middle protection 8 Vermiculite upper protection 9 Vermiculite side protection 10 Chamber outer thermal protection 11 Protection support cover 12 Turbulator support 13 Turbulators 14 Fire door 15 Safety valve 16 Ash door 17 Ash box 18 Heating chamber 61 DOMUSFIRE C29 C35 C39 COLA Exploded views of 1 Brazier assembly 2 Fume extractor assembly 3 Auger assembly Key 1 Brazier 2 Brazier holder 3 Internal baffle 4 Air inlet pipe 5 Heater 6 Seals 7 Air flow meter Key 1 Fume extractor coil 2 Thermal seal 3 Fume extractor motor 4 Fume exhaust pipe 5 Seal Key 1 Conveyor hopper seal 2 Gearmotor support flange 3 Gearmotor 4 Auger 5 Seal for chute 6 Pellet chute 7 Conveyor chamber seal 8 Pellet conveyor 62 DOMUSFIRE C29 C35 C39 6 4 Electrical components DOD AOE 6 5 Standard hydraulic compon
151. e with Italian Standard UNI10683 FLUE a vertical duct for collecting and expelling at an appropriate height from ground the fumes coming from a single unit and where permitted more than one hg FLUE technical requirements it must be fumetight isolated and ln ts insulated depending on its use LI it must have a mainly vertical path with axis deviation lt 45 Flue m di i it must be placed at a suitable distance from flammable materials by means of insulation or air gap Flue it must preferably have a continuous free and independent round internal f connection section of Inspectiona it is advisable for the flue to have an inspectionable chamber for the ble chamber collection of solid materials d on and any condensate placed under the beginning of the fume duct E min 100 ome Min distance 0 2m D FLUE CONNECTION or DUCT duct or connection element between the unit and flue for evacuation of fumes DUCT technical requirements it must not cross rooms where the installation of combustion units is not allowed flexible metal tubes or fibre cement pipes are prohibited the use of counter sloping elements is prohibited horizontal sections must have an upward slope of at least 3 the length of the horizontal section must be minimal and not more than 3 m there must not be more than 3 changes of direction without the T union with change of direction
152. e zur Wiederherstellung WASSERTE Wassertemperaturf hler defekt ist Der F hler E defekt des Kesselbetriebs m ssen von einer Der F hler ist nicht an der Platine sh MPERATURF und T dde zh C anzeigt angeschlossen autorisierten Kundendienststelle Pe Der Abschaltvorgang wird durchgef hrt werden UHLER aktiviert AL d Wird ausgel st wenn die Nach der Ursache f r das Problem Wassertemperatur die vorgegebenen Wird ausgel st wenn der suchen die Temperatur wieder HOT Grenzwerte berschritten hat Temperaturf hler in der Heizkammer herstellen und auf den f r den WASSER Das System wird gestoppt einen h heren Wert als 92 C misst normalen Betrieb vorgeschriebenen Wert bringen ABKUHLEN Wird ausgel st wenn der Kessel Entst rversuch w hrend des Der Alarm kann erst zur ckgesetzt BITTE sofort nach dem Ausschalten wieder Abschaltvorgangs mit noch warmem werden nachdem der Kessel eingeschaltet wird Kessel in Abk hlphase vollst ndig abgeschaltet wurde WARTEN 9299 DEFEKT er ie Regelung kann die Menge der Die Vorg nge zur Wiederherstellung Wird ausgel st wenn der erbrennungsluft nicht messen des Kesselbetriebs m ssen von einer LUFTMASSE 3 schaltet jedoch den Kessel nicht ab Luftmassenmesser getrennt wird d hli ie Funkti autorisierten Kundendienststelle NMESSER sondern schlie t nur die Funktionen durchgef hrt werden des Luftmassenmessers aus i Die Pumpe l uft an um das Wasse
153. ecci n intermedia 8 Protecci n superior vermiculita 9 Protecci n lateral vermiculita 10 Protecci n t rmica exterior c mara 11 Tapa de soporte protecciones 12 Soporte de los turbuladores 13 Turbuladores 14 Puerta c mara de combusti n 15 V lvula de seguridad 16 Puerta del cenicero 17 Cenicero 18 C mara t rmica DOMUSFIRE C29 C35 C39 COLA Despieces de 1 Grupo brasero 2 Grupo extractor de humos 3 Grupo sinfin Leyenda 1 Brasero 2 Portabrasero 3 Deflector interno 4 Tubo de aspiraci n de aire 5 Resistencia el ctrica 6 Juntas 7 Deb metro Leyenda 1 H lice extractor de humos 2 Junta t rmica 3 Motor extractor de humos 4 Tubo de salida de humos 5 Junta Leyenda 1 Junta dep sito conducto 2 Brida del motorreductor 3 Motorreductor 4 Sinf n 5 Junta para rampa 6 Rampa de ca da de pellets 7 Junta c mara conducto 8 Conducto de pellets 157 DOMUSFIRE C29 C35 C39 COLA 6 4 Componentes el ctricos Leyenda 1 Panel de mandos mod EVO 2 Termostatos de seguridad 3 Interruptor ON OFF con fusibles 4 Tarjeta electr nica 5 Cable de alimentaci n el ctrica 6 Vacuostato f DH 7 Transductor de presi n circuito hidr ulico an 7 Sonda de humos de 8 Sonda de agua camara t rmica 9 Sonda agua acumulador dep sito inercia OOD OOOOO g p 10 Sonda de nivel en dep si
154. eference 10 O gt Emissione NOx al 10 O 6 1 32 7 1 1 32 7 9 1 32 0 005 0 040 0 007 0 040 0 009 0 040 130 2 116 4 3 i 1 d 3 i gd E ES 24 5 9 5 0 004 0 029 0 005 0 029 0 006 0 029 4 9 13 78 4 8 13 78 4 9 13 78 E 7 mim I JH 3 gi El 8 IR o E 3 z 9 3 D 3 1 106 8 84 6 107 84 6 94 7 84 6 17 6 6 9 17 2 6 9 17 8 6 9 mg m 19 66 12 69 19 22 12 69 19 86 12 69 Set max temp Pressione max acqua di esercizio eee gt e Capacit acqua caldaia LI Capacit serbatoio pellet SS Classe della caldaia rif EN303 5_2012 A _ Sr EEE RES Water resistance AT 10K mer eee Water resistance AT 20K Temperatura uscita fumi tee 9 ee stes sers EZ EIRE Flue gas flow 10 14 0 10 0 14 m THEE 3 Ela pla ER OR EES 3 aUo lo ga 2 o 156 2 521 7 624 7 Tiraggio canna fumaria min max Pa Draught min max Diametro tubo scarico fumi EJ Fume outlet pipe Alimentazione elettrica 230V 50Hz 6A Electrical power UN Assorbimento elettrico Rated input e Accensione Start 476 Stand by 4 P nom 160 153 A AERE 1300 700 698 1300 700 698 1300 700 698 Dimensions HxLxP alla Potenza nominale e Potenza ridotta Nominal output an
155. eh lter vollst ndig ausleeren Den Stromanschluss trennen Gr ndlich s ubern und bei Bedarf alle besch digten Teile von Fachpersonal ersetzen lassen Den Kessel abdecken um ihn vor Staub zu sch tzen An einem trockenen witterungsgesch tzten Ort unterstellen 5 REINIGUNG DES HEIZKESSELS Der Kessel muss unbedingt regelm ig gereinigt werden um folgende Probleme zu vermeiden schlechte Verbrennung Ablagerung von Asche und unverbrannten Stoffen im Brenntopf sowie geringere Heizleistung Der Kessel darf nur mit geschlossener Feuert r und geschlossener Aschent r betrieben werden Die Dichtungen der T ren m ssen regelm ig kontrolliert werden damit kein Luft eindringen kann da die Brennkammer in Unterdruck gehalten werden muss Die ordentliche Reinigung wird normalerweise vom Kunden unter Befolgung der im Benutzerhandbuch enthaltenen Anleitungen vorgenommen w hrend die au erordentliche Wartung mindestens 1 Mal pro Jahr vom Vertragskundendienst durchgef hrt werden muss S mtliche Kesselteile d rfen nur gereinigt werden wenn der Kessel vollst ndig abgek hlt und vom A Stromnetz getrennt ist Die Reinigungsr ckst nde gem den geltenden rtlichen Vorschriften entsorgen Der Kessel darf auf keinen Fallohne Au enverkleidungen in Betrieb gesetzt werden W hrend des Z ndvorgangs und oder beim normalen Betrieb die Bildung von Rauch und unverbrannten Stoffen vermeiden Nachstehend werden die Kontroll und oder W
156. emisch physikalischen Eigenschaften des Anlagenwassers und des nachgef llten Wassers sind wichtig f r den korrekten Betrieb und die Lebensdauer des Kessels bei Verwendung von Wasser schlechter Qualitat stellen die h ufigsten St rungen die Verkalkungen dar die die Reduzierung des W rmeaustausches und Korrosion verursachen Es wird daher empfohlen die Wasserqualitat zu kontrollieren und bei Eintreten der unten aufgef hrten Bedingungen eine Behandlung durchzuf hren hohe Wasserh rte gt 20 F erhebliche Mengen an nachgef lltem Wasser besonders groBe und komplexe Anlagen 2 9 3 Anlage f r Warmwasserbereitung F r den Anschluss des Heizkessels an eine Brauchwasseranlage wenden Sie sich bitte an einen kompetenten Fachmann um die Wasseranschl sse und die Leistungen der ganzen Anlage zu optimieren ohne die Funktionen des Ger ts einzuschranken F r den Anschluss an den Brauchwasserkreislauf muss eine der folgenden optionalen Ausstattungen angefordert werden Brauchwasserpumpe am Vorlauf mit dazugeh renden Verbindungsrohre zum Einbau in den Kessel oder Brauchwasserpumpe Plattenw rmetauscher und Verbindungsrohre zum Einbau in den Kessel oder ein 3 Wege Ventil zur Installation auBerhalb des Kessels 110 DOMUSFIRE C29 C35 C39 COLA Nach erfolgtem Brauchwasseranschluss muss das technische Men der Regelung ge ffnet und die Art des Kreislaufs gewahlt werden jede eingegebene spezifische Brauchwasserfunktion BRAUCHWASS
157. en Erh hen Verringern P1 P2 dr cken um den gew nschten Parameter einzustellen die Taste SET P3 dr cken um den Parameterwert zu best tigen Nach ffnen des Men s k nnen die verschiedenen Anzeigearten eingerichtet und die je nach Zugriffsebene verf gbaren Einstellungen vorgenommen werden 114 DOMUSFIRE C29 C35 C39 COLA In der nachstehenden Tabelle sind die Befehle und die wahrend der Programmierung oder Einstellung der Betriebsparameter jeweils angezeigten Meldungen aufgef hrt Taste Beschreibung Betriebsart Vorgang Oberes Display Unteres Display Grenzwerte Luft 7 C wwe aan SET H20 Luft Temperatur RAUMTHERMOSTATS erh hen p 1 Temperatur 30 C 80 erh hen x Gew hlter PROGRAMMIERUNG Gew hlten Parameterwert erh hen Pranger Parameterwert ARBEIT Temperaturen anzeigen Abgastemperatur Wassertemperatur Luft 7 C SETMEMPERATUR Temberatunwen dos Wasser Und des SET H20 Luft Temperatur SE Raumthermostats verringern 30 C 80 2 Temperatur verringern A E Gew hlter PROGRAMMIERUNG Gew hlten Parameter verringern Parameterwert Druck im Drehzahl ARBEIT Betriebszustand des Kessels anzeigen Weste Abgasventilator Temperatur SET und Men mit den si benutzer technikerdefinierten Parametern Zar Maul mit aufeinanderfolgenden Tastendr cken So nas Lema von ffnen 2 Sekunden dr cken um den Erreichten ARBEI
158. eni di consumo e regolamenta il rapporto tra Venditore finale e Consumatore La Direttiva in oggetto prevede che in caso di difetto di conformit del prodotto il Consumatore ha diritto a rivalersi nei confronti del Venditore finale per ottenerne il ripristino senza spese dei difetti manifestatisi entro il termine di 24 mesi dalla data di consegna La Ditta COLA Srl pur non essendo Venditore finale nei confronti del Consumatore intende comunque supportare le responsabilit del Venditore finale con una propria Garanzia Convenzionale fornita tramite la propria rete di assistenza tecnica autorizzata alle condizioni riportate di seguito Oggetto della Garanzia e durata Con la presente Garanzia convenzionale l azienda Produttrice garantisce da tutti i difetti di fabbricazione e di funzionamento gli apparecchi venduti per 24 mesi dalla data di consegna documentata attraverso regolare documento di acquisto purch avvenuta entro 3 anni dalla data di fabbricazione del prodotto La messa in servizio del prodotto deve essere effettuata a cura di un Installatore qualificato ed entro 30 giorni dalla messa in servizio il Cliente deve richiedere ad un Centro Assistenza autorizzato il primo controllo gratuito e la validazione della Garanzia Si precisa che la Garanzia decorre sempre dalla data di consegna documentata Sono espressamente escluse dalla presente garanzia convenzionale le parti di normale usura guarnizioni manopole vetro parti in vermi
159. ent AL 4 lorsque le ventilateur d aspiration L en per ASPIRAT des fum es ast d faillant Le capteur de controle de l allure du fonctionnement normal doivent DEFAILLANT La proc dure d extinction est la vitesse est d faillant tre effectu es par un centre aves Le courant lectrique n arrive d assistance pas au ventilateur des fum es V rifier la pr sence de granul s Le r servoir granul s est vide dans le r servoir AL5 La petite flamme ne s allume pas La r sistance lectrique est V rifier les proc dures ALLUMAGE en phase d allumage d fectueuse encrass e ou n est d allumage SSC a La proc dure d extinction est pas correctement en place D autres op rations de RATE activ e R glage du chargement des r tablissement du fonctionnement granul s incorrect normal doivent tre effectu es par un centre d assistance V rifier la pr sence de granul s Le r servoir granul s est vide dans le r servoir AL 6 Le fonctionnement du R gler l alimentation des ABSENCE DE Le brasier n est pas aliment en motor ducteur de chargement des granul s granul s granul s doit se r gulariser D autres op rations de GRANULES Le motor ducteur ne charge pas r tablissement du fonctionnement les granul s normal doivent tre effectu es par un centre d assistance Le thermostat de s curit a Senke Cette alarme se declenche en relev une temp rature S AL 7 cas d intervention du the
160. entrada de aire comburente y salida de humos La caldera no se debe utilizar como incinerador sino exclusivamente para calentar el agua de una instalaci n de calefacci n y o agua sanitaria utilizando como nico combustible pellets de madera que tengan las caracter sticas descritas en este manual No utilizar l quidos u otras sustancias inflamables para ayudar al encendido No utilizar la caldera para incinerar residuos No manipular sustancias f cilmente inflamables o explosivas cerca de la caldera encendida Evitar el contacto directo con las partes del equipo que se calientan durante el funcionamiento Antes de hacer cualquier operaci n de mantenimiento desconectar la caldera de la corriente el ctrica y dejar que se enfr e Enel local de instalaci n debe haber una temperatura ambiente comprendida entre 0 C y 35 sin excesiva humedad por ejemplo no tender ropa a secar manipular sustancias f cilmente inflamables o explosivas cerca de la caldera encendida A Est prohibido modificar los dispositivos de seguridad o de regulaci n sin autorizaci n expresa del fabricante Las modificaciones de la caldera o el uso de recambios no originales sin la debida autorizaci n pueden poner al usuario en peligro ante lo cual el fabricante queda exento de responsabilidad civil y penal 131 DOMUSFIRE C29 C35 C39 COLA Utilizar solo recambios originales indicados por el fabricante caso de anomal
161. entre case of operation faults the boiler can only be after eliminating the cause of the problem otherwise contact the After Sales Service The manufacturer declines any liability for problems breakage or accidents caused by failure to follow or apply the instructions contained in this manual 38 DOMUSFIRE C29 C35 C39 COLA 1 4 Technical description The boiler works exclusively on pellets and enables easy installation with the heating and DHW system lts automatic control systems ensure optimum thermal efficiency and complete combustion there are also systems to ensure safe operation for the internal components and the user This unit must only be used for heating water to a temperature lower than boiling point When correctly installed the unit works in any outside climatic conditions in any case in critical conditions strong wind frost etc the safety systems can cut in and shut down the boiler Technical data boiler model DOMUSFIRE Caldaia a pellet Heating Boiler DOMUSFIRE DOMUSFIRE DOMUSFIRE C29 C35 C39 Pellet di legno Wood pellet UNI EN14961 2 classe A1 27 4 5 78 324 5 78 34 9 5 78 94 45 90 14 94 18 90 14 91 32 90 14 Heating input Potenza termica utile Water heating output Rendimento termico Efficiency Consumo orario Fuel consumptio Emissione CO al 10 O2 Emission CO at reference 10 O2 Emissione CnHm al 10 O Emission CnHm at r
162. ents Psp MI OO 63 COLA Key 1 Control panel EVO model 2 Temperature safety thermostats 3 ON OFF switch with fuses 4 Electronic board 5 Power cable 6 Vacuum switch 7 Water circuit pressure transducer 7 Fume probe 8 Heating chamber water probe 9 Puffer storage tank water probe 10 Level probe on pellet hopper 11 Serial connection 12 Pressure transducer Key 1 Membrane expansion tank 2 System drain cock 12 3 Pressure relief valve 4 Delivery pipe with connections 1 5 Circulating pump 6 Return pipe with connection 1 7 Pressure transducer 8 System filling connection V2 9 Boiler system air venting valve DOMUSFIRE C29 C35 C39 7 TROUBLESHOOTING 7 1 Alarm management Alarms are indicated by an acoustic signal if activated and a message on the control panel In case of an alarm shut down the boiler eliminate the cause and restart the boiler according to the normal procedure described in this manual Every alarm status causes immediate boiler shutdown The alarms with causes and cures which can appear on the control panel are listed below COLA ALARMS MESSAGES Signalling Fault Possible causes Cures Turn the boiler OFF by AL 1 pressing the button P4 and 2 No power during the lighting repeat the lighting procedure POWER The boiler does not start s
163. enza provveder ad inviare copia della relazione d intervento al Produttore con i 2 bollini originali a prova dell avvenuto intervento COLA S r l Viale del Lavoro 37040 Arcole VR Italy tel 045 7635780 045 6144043 Fax 045 6144048 e mail info anselmocola com on line www anselmocola com Partita IVA e Codice Fiscale 02990180230 Fax Amministrazione 045 7639029 Fax Commerciale 045 6144048 Fax Assistenza 045 7639030 3 DOMUSFIRE C29 C35 C39 La Ditta COLA garantisce i propri prodotti secondo le norme attualmente in vigore ad esclusione delle parti soggette a normale usura Per le condizioni di garanzia rivolgersi all importatore al rappresentante autorizzato il quale puo integrare il periodo della garanzia obbligatoria con un periodo supplementare a sua totale ed esclusiva responsabilit La garanzia del prodotto decade per qualsiasi inconveniente rottura o incidente dovuto al mancato rispetto o applicazione delle indicazioni contenute nel presente manuale COLA guarantees its products except for parts subject to normal wear in accordance with the current regulations For the warranty terms please contact the importer or the authorised agent who can integrate the compulsory warranty period with an additional period under his sole and exclusive responsibility The product warranty is invalidated for any trouble breakage or accident due to failure to comply with or apply the instructions provided in this manual La so
164. er Technik muss eine Heizungsanlage mit allen Vorrichtungen f r Einstellung Kontrolle und Sicherheit ausger stet sein die einen ordnungsgem en sicheren Betrieb garantieren sowie mit Sperr und R ckschlagventilen mit denen der Kessel f r Wartungseingriffe und oder Kontrollen von der Anlage getrennt werden kann Es gibt zwei Anlagenarten Anlage mit OFFENEM AUSDEHNUNGSGEFASS und Anlage mit GESCHLOSSENEM AUSDEHNUNGSGEFASS in unserem Fall sind beide Anlagenarten mit dem Ger t kompatibel vorausgesetzt es werden s mtliche von den geltenden Installationsbestimmungen vorgeschriebenen Vorrichtungen f r Einstellungen Kontrolle und Sicherheit installiert Der Pelletkessel enth lt den Heizwasserkreislauf mit Umw lzpumpe Sicherheitsventil Entl fter Temperaturf hler und Druckmessumformer Wird die Heizanlage abschnittsweise gesteuert muss unbedingt ein auf Anfrage erh ltlicher Mehrzonenregler eingebaut werden Um zu vermeiden dass w hrend der Heizphase kaltes Wasser in die Heizkammer zur cklaufen kann wird f r Festbrennstoffkessel empfohlen ein AUTOMATISCHES THERMOSTATVENTIL auf Anfrage lieferbar in die Anlage einzubauen Damit wird die Effizienz der Verbrennung und die Lebensdauer des Kessels verbessert und die Bildung von Kondensaten der Abgase in den Rauchabz gen sowie die Menge von Verkalkungen und Teer reduziert Vor Anschluss des Kessels an der Wasseranlage m ssen alle Leitungen der Anlage sorgf ltig gereinigt werden um event
165. ermostat temp rature canal d alimentation granul s Rallumer la chaudi re normalement Temp rature de d clenchement du thermostat du r servoir de granul s gt 85 3 5 S curit contre le retour de flamme sur le canal d alimentation en granul s Les solutions pour emp cher le retour de flamme sont d pression dans la chambre de combustion voir 3 2 gt La forme en siphon du canal d alimentation des granul s gt La s curit sur la temp rature du r servoir voir 3 4 3 6 Dispositif lectrique de protection contre les surtensions L appareil est prot g contre les surtensions par un des fusible s de 2 A sur l alimentation de l interrupteur g n rale de la chaudi re situ l arri re de celle ci 3 7 S curit contre la surpression du circuit hydraulique Toute surpression de l eau l int rieur de la chambre pour P gt 3 bars est d charg e par la soupape de s ret install e sur le circuit hydraulique l int rieur de la chaudi re A Il est interdit d intervenir sur les dispositifs de s curit 3 8 Dysfonctionnement du ventilateur d extraction des fum es Si pour une raison quelconque le ventilateur d extraction des fum es s arr te de fonctionner l lectronique de commande bloque instantan ment l alimentation des granul s et affiche le message 4 ASPIRAT DEFAILLANT 81 DOMUSFIRE C29 C35 C39 COLA 4 UTILISATION DE LA CHAUDIERE 4 1 Introduction La chaudi re a granul s
166. es Wassers in der Kammer von P gt 3 bar wird durch Ansprechen des an der Wasseranlage im Kessel eingebauten Sicherheitsventils abgelassen An den Sicherheitseinrichtungen d rfen keine Eingriffe vorgenommen werden 3 8 Abgasgebl se defekt Wenn aus irgendeinem Grund das Saugzuggebl se stehen bleibt blockiert die elektronische Regelung sofort die Pelletzuf hrung und die Meldung AL4 ABGASVENT DEFEKT wird angezeigt 113 DOMUSFIRE C29 C35 C39 COLA 4 GEBRAUCH DES KESSELS 4 1 Vorwort Der Pelletkessel vereint die wohlige Warme von Holzfeuer mit der bequemen automatischen Temperaturregelung Er bietet auBerdem der M glichkeit die Ein und Ausschaltung f r die ganze Woche zu programmieren und bei Anschluss eines Thermostats und oder Uhrenthermostats die Fernsteuerung Start Stopp F r einen sicheren und zuverl ssigen Betrieb befolgen Sie bitte die nachstehenden Vorschriften Bei der Erstinbetriebnahme k nnen unangenehme Ger che auftreten daher sollten Sie f r eine gute Bel ftung des Raums sorgen Dies gilt vor allem f r die erste Betriebszeit Der Beh lter darf ausschlieBlich mit hochwertigen Pellets beschickt werden beim Nachf llen vermeiden dass der Beutel mit der heiBen Oberfl che des Kessels in Kontakt kommt Keinen anderen Brennstoff als Pellets die die Vorschriften erf llen in den Beh lter einf hren Das Ger t darf nicht zur M llverbrennung verwendet werden Der Kessel darf ausschlieBlich mit geschlossene
167. es horaires agir sur les six boutons en respectant le tableau au paragraphe 4 2 Aller dans le sous menu PROGRAM JOUR pour valider d sactiver et pr s lectionner les fonctions du chronothermostat journalier Il est possible de r gler deux phases de fonctionnement d limit es par les horaires configur s selon le tableau ci apr s o la programmation OFF indique l horloge d ignorer la commande s lection signification valeurs possibles START1 heure de validation heure OFF STOP1 heure de d sactivation heure OFF START2 heure de validation heure OFF STOP2 heure de d sactivation heure OFF Aller dans le sous menu PROGRAM SEMAINE pour valider d sactiver et pr s lectionner les fonctions du chronothermostat hebdomadaire Le programmateur hebdomadaire dispose de 4 programmes ind pendants qui en final se traduisent par la combinaison des 4 programmations Le programmateur hebdomadaire peut galement tre valid ou d sactiv en programmant OFF dans la case des horaires l horloge ignore la commande correspondante A La programmation doit se faire avec grande attention Eviter de faire chevaucher les heures d activation et ou de d sactivation dans le m me jour au sein de diff rents programmes Aller dans le sous menu PROGRAM WEEK END pour valider d sactiver et pr s lectionner les fonctions du chronothermostat durant le week end fin de semaine samedi dimanche
168. es minimales n cessaires la maintenance et la s curit doivent respecter le tableau ci apr s R SERVOIR SUPPL MENTAI RE EN OPTION A 500 mm B 500 mm C 500 mm D 1000 mm L 1450 mm P 700 mm 74 DOMUSFIRE C29 C35 C39 COLA La chaudi re est dot e de 4 pieds r glables pour faciliter sa mise en place sur des sols irr guliers Pour r gler la hauteur du pied incliner la chaudi re et tourner le pied jusqu a obtenir la bonne hauteur 2 3 Prise d air La chaudi re doit disposer de l air de combustion n cessaire pour garantir son fonctionnement a travers des prises d air et plus pr cis ment a proximit de la chaudi re pr voir une prise d air murale pr sentant une surface minimum de 100 cm convenablement positionn e afin de ne pas tre obstru e et prot g e par une grille ext rieure gt ou un passage direct avec l ext rieur travers un tube de 1 5 m maximum de long et avec un diam tre int rieur de 60 mm dont l extr mit sera d ment prot g e encore a travers la pi ce voisine o l arriv e d air sera directe grace des ouvertures permanentes communiquant avec l ext rieur et r pondant aux conditions d crites ci avant La pi ce voisine ne doit pas se trouver en condition de d pression par rapport l ext rieur sous l effet d un tirage induit par la pr sence d autres appareils ou de dispositifs d aspiration La pi ce voisine ne pourra pas
169. eservoirs erfasst THERMOSIC System gestoppt wird Blockieren der Funktion des Uberhitzung betroffenen Thermostats HERUNG Getriebemotors durch Dr cken der Reset Taste wieder herstellen 127 DOMUSFIRE C29 C35 C39 COLA Anzeige Betriebsstorung Mogliche Ursachen Abhilfen Kontrollieren ob Rauchabzugsrohr und Brennkammer sauber sind AL8 Die Brennkammer ist verschmutzt Kontrollieren ob die T r dicht W hrend der Betriebsphase liegt der Das Rauchabzugsrohr ist verstopft verschlossen ist KEIN vom Kessel gemessene Druck unter Die Feuerraumtir ist nicht Kontrollieren ob die UNTERDR der Ansprechschwelle des geschlossen Berstschutzventile geschlossen sind U Unterdruckw chters Die Berstschutzventile sind Andere Vorg nge zur CK Das System wird gestoppt offen verklemmt Wiederherstellung des Kesselbetriebs Der Unterdruckw chter ist defekt m ssen von einer autorisierten Kundendienststelle durchgef hrt werden Kontrollieren ob Rauchabzugsrohrund Brennkammer Die Brennkammer ist verschmutzt sauber sind Kontrollieren ob die T r dicht Das Rauchabzugsrohr ist verstopft c AL 9 Wird ausgel st wenn die Die Feuerraumt r ist nicht ne IDE UNGENUGE verbrennungsluftzufuhr unter einem geschlossen B IE hi ob die NDER ZUG bestimmten Schwellenwert liegt Die Berstschutzventile sind gssen sind offen verklemmt e Der Luftmassenmesser ist defe
170. ets mit anderen Eigenschaften als vom Techniker bei der ersten Inbetriebnahme getestet m ssen die Parameter der Pelletbeschickung des Kessels neu eingestellt werden Dieser Eingriff ist von der Garantie ausgeschlossen Die Pellets m ssen an einem trockenen vor Feuchtigkeit gesch tzten Ort gelagert werden Um eine regul re und effiziente Funktionsweise zu garantieren k nnen die Pellets oder andere A Brennstoffe nicht von Hand in den Brenntopf eingef llt werden Mit der Zeit sammelt sich im Pelletbeh lter Staub an der die regulare Pelletzuf hrung beeintrachtigen k nnte daher wird empfohlen vor dem Einftillen der Pellets gegebenenfalls den Staub zu entfernen Den Beh lter nicht mit ungeeigneten Brennstoffen f llen Keine Fremdk rper in den Beh lter einf hren z B Verpackungen Schachteln Beutel Metall usw Durch die Verwendung minderwertiger und ungeeigneter Pellets wird das Ger t besch digt und sein Betrieb beeintr chtigt In diesem Fall verf llt jeder Garantieanspruch und die Haftung des Herstellers 1 6 Mitgeliefertes Zubeh r Der Lieferumfang umfasst Netzkabel Installation Gebrauchs und Wartungsanleitung Schl ssel zum ffnen Schlie en 104 DOMUSFIRE C29 C35 C39 COLA 1 7 Bezugsnormen Norm EN 303 5 2012 Begriffe Anforderungen Pr fungen und Kennzeichnung von Heizkesseln f r feste Brennstoffe hand und automatisch beschickte Feuerungen Norm EN 60335 1 Sicherheit elektrischer Ger
171. eurs et des tubes de fum e dans la chambre Il est important en outre de nettoyer l extracteur des fum es situ l arri re du collecteur inf rieur des fum es auquel on acc de travers la trappe de visite qui se trouve derri re le cendrier Tous les 3 4 mois nettoyer les parois internes de la chambre de combustion et du collecteur sup rieur des fum es avec des outils pinceaux brosses appropri s et remplacer ventuellement le matelas de vermiculite car consid r comme un consommable La chaudi re signale toutes les 1800 heures de fonctionnement travers un message ECHEANCE ENTRETIEN la n cessit d effectuer un entretien extraordinaire non couvert par la garantie par un professionnel qualifi qui proc dera un nettoyage complet et la r initialisation du message A Tous chocs ou for ages ventuels peuvent endommager l extracteur des fum es et rendre son fonctionnement bruyant Par cons quent faire effectuer cette op ration par un professionnel qualifi 5 4 Nettoyage du d bitm tre Le tuyau d aspiration renferme un d bitm tre mesureur du d bit d air comburant qui n cessite tous les 3 4 mois d un nettoyage des parois internes l aide d un outillage appropri jet d air comprim ou pinceaux appropri s 5 5 Nettoyage du conduit de raccordement conduit de fum e Le conduit de raccordement doit tre nettoy au moins une fois par an ou toutes les fois que cela s av re n cessair
172. fin interc APAGADO OFF OFF OFF OFF ON OFF START PRECAL 40 ON ON OFF OFF transcurso tiempo 40 PRECARGA PELLETS Pr40 ON ON ON OFF transcurso tiempo Pr40 ESPERA LLAMA Pr41 ON ON OFF OFF transcurso tiempo Pr41 CARGA PELLETS ON ON ON OFF temperatura humos gt Pr13 FUEGO PRESENTE Pro2 OFF ON ON ON transcurso tiempo Pr02 temperatura ambiente lt consigna temperatura TRABAJO om SN ON ON temperatura humos lt Pr14 temperatura ambiente lt consigna temperatura OFF ON ON ON temperatura agua gt consigna agua temperatura TRABAJO MODULA humos lt 14 LIMPIEZA BRASERO Pri2 OFF ON ON ON con frecuencia Pr03 TRABAJO OFF ON ON ON ON OFF para apagar Pr39 transcurre desde el momento en que T humos lt Pr13 LIMPIEZA FINAL Pr39 OFF ON OFF Al un cierto tiempo si la temperatura de los humos no ha alcanzado el valor minimo admitido la caldera activa el estado de alarma Est prohibido utilizar l quidos inflamables para el encendido Si el encendido falla repetidamente llame al Servicio T cnico COLA S r l 147 DOMUSFIRE C29 C35 C39 COLA 4 16 Funcionamiento Si la PUESTA EN MARCHA termina correctamente la caldera pasa al modo TRABAJO que es el de funcionamiento normal El usuario puede regular la potencia de calefacci n entre 1 y 5 mediante las teclas P5 y P6 La activaci n ON de la producci n de ACS se indica en pantalla con el s mbolo A 58
173. flusso del pellet AL 3 p Ridotto scambio termico Altre operazioni di ripristino fumi superiore a 280 C HOT FUMI Vjene Dia la la di nell impianto devono essere condotte da un spegnimento centro di assistenza AL A Avviene quando il ventilatore j GE ee MEN L ioni di ripristi di aspirazione fumi guasto Il sensore controllo velocit Le operazioni di ripristino ASPIRAT Viene attivata la procedura gi 1008810 devono essere condotte da GUASTO Manca l alimentazione un centro di assistenza peg i elettrica al ventilatore fumi 11 serbatoio del pellet vuoto a a AL5 In fase di accensione non La resistenza elettrica amp a le rocedur di parte la fiamma difettosa sporca o fuori dalla MANCATA ig accensione Viene attivata la procedura di corretta posizione ot oer ACCENS spegnimento Taratura carico pellet non vuU Dera fons HI HANSINO corretta devono essere condotto da un centro di assistenza Verificare la presenza di AL6 RI serbatoio del pellet vuoto pellet nel serbatoio N li Il motoriduttore di carico pellet Beoolare I pell MANCANO on viene alimentato di Regolare lusso de pel et ellet il braciere Altre operazioni di ripristino lb Il motoriduttore non carica Aura op PELLET ellet devono essere condotto da P i un centro di assistenza Il termostato di sicurezza ha ss rilevato una temperatura
174. fornitura di pellet visualizzando il messaggio ALA ASPIRAT GUASTO 19 DOMUSFIRE C29 C35 C39 COLA 4 USO DELLA CALDAIA 4 1 Premessa La caldaia a pellet presenta il vantaggio di unire il calore generato dalla combustione del legno alla comodita della gestione automatica della temperatura dell acqua con la possibilit di programmare settimanalmente l accensione e lo spegnimento nonch con il collegamento di un termostato e o cronotermostato il comando remoto di start stop Per un utilizzo sicuro e affidabile consigliato osservare le seguenti prescrizioni la prima messa in funzione si possono riscontrare cattivi odori pertanto si deve provvedere ad una buona aerazione del locale soprattutto durante il primo periodo di funzionamento il caricamento del serbatoio deve essere fatto esclusivamente con pellet di qualit durante tale operazione evitare che il sacco venga a contatto con le superfici calde della caldaia inserire nel serbatoio nessun altro tipo di combustibile che non sia pellet conforme a quanto prescritto l apparecchio non deve essere utilizzato come inceneritore di rifiuti la caldaia deve funzionare solo ed esclusivamente con la porta fuoco sempre chiusa le guarnizioni della porta fuoco e cenere devono essere controllate periodicamente per evitare che vi siano infiltrazioni d aria per garantire un efficiente rendimento termico ed una corretta funzionalit necessario effett
175. g Warmetauscher Z Brauchwasservorlauf OPT 1 2 Innengewinde Warmetauscher 103 DOMUSFIRE C29 C35 C39 COLA Offnen SchlieBen der Feuerraumttir Kessel Mod DOMUSFIRE Zum Offnen der uBeren T r nach auBen ziehen Griff zum Offnen SchlieBen der Feuerraumt r und der Tur des Aschekastens Offnen Gegen den Uhrzeigersinn SchlieBen Im Uhrzeigersinn 1 5 Brennstoff und zulassiger Gebrauch Zum ffnen der T r den mitgelieferten Griff einsetzen und im Uhrzeigersinn drehen Die Pelletkessel funktionieren ausschlie lich mit Pellets Presslingen aus verschiedenen Holzarten die die Vorschriften der Normen DIN Plus 51731 oder EN 14961 2 oder O Norm M 7135 erf llen bzw folgende Eigenschaften aufweisen Heizwert min 4 8 kWh kg 4180 kcal kg Dichte 680 720 kg m3 Feuchtigkeit max 10 des Gewichts Durchmesser 6 0 5 mm Aschenanteil max 1 5 des Gewichts L nge min 6 mm max 30 mm Zusammensetzung 100 unbehandeltes Restholz aus der Holzindustrie oder aus Recycling ohne Zugabe von Bindestoffen und ohne Rinde gem den geltenden Vorschriften Verpackung in Beuteln aus komaterial bzw biologisch abbaubarem Material oder Papier Der Pelletsbeh lter befindet sich im hinteren Bereich des Kessels Die T r befindet sich im oberen Teil und die Beschickung erfolgt von Hand nur bei eingeschaltetem Kessel dabei darauf achten dass der Beh lter nicht berl uft Bei Verwendung von Pell
176. gt 90 a max of 2 bends can be used with length in horizontal projection not exceeding 2 m the fume duct must have a continuous section and allow the recovery of soot CHIMNEY CAP a device placed on the top of the flue to facilitate the dispersion of fumes into the atmosphere CHIMNEY CAP technical requirements it must have a section equivalent to that of the flue it must have a useful section not less than double the internal section of the flue it must prevent the entry of rain and foreign bodies and ensure the discharge of fumes in any atmospheric condition it must ensure an adequate dilution of fumes and be positioned outside the backflow area it must be without mechanical means of suction A The direct discharge of fumes must take place on the roof and not towards closed spaces even open air 2 5 Turbulator and brazier position check Before lighting the boiler make sure the brazier is in the correct position i e fitted in the special slots Also make sure the turbulator shaker device is resting in the lower position An incorrect position of the brazier and or turbulators can result in malfunctioning and excessive creation of dusts and unburnt products A At every unit lighting check the correct position of the brazier and turbulator shaker device 2 6 Electrical connection Connect one end of the power cable to the rear socket of the stove and the other to a wall socket The voltage supplied by the
177. gua establecer Set max temp C Presi n m xima de funcionamiento bar Max working pressure Capacidad de la c mara t rmica Heating chamb I ating chambre capac Capacidad del dep sito kg Pellet stove capacity Clase de caldera rif EN303 5_2012 Boiler class rif EN303 5 2012 P rdida de carga en lado del agua AT 10K 386 9 5217 6247 Water resistance AT 10K P rdida de carga en lado del agua AT 20K Water resistance AT 20K kg PA C anna 134 3 62 6 148 6 62 6 159 5 62 6 Fume outlet temperature Caudal de humos 9 14 1 54 163 54 182 54 Flue gas flow ls Tiro m n max Pa 10 1 10 0 14 Draught min max mbar 0 14 0 10 0 14 146 7 116 4 147 1 116 4 130 2 116 4 24 1 9 5 23 6 9 5 24 5 9 5 mg m 0 004 0 029 0 005 0 029 0 006 0 029 mg m 4 9 13 78 4 8 13 78 4 9 13 78 mg m 106 8 84 6 107 84 6 94 7 84 6 mg m 17 6 6 9 17 2 6 9 17 8 6 9 mg m 19 66 12 69 19 22 12 69 19 86 12 69 100 230V 50Hz 6A Accensione 476 Stand by4 P nom 160 P rid 153 Rated input power cerda mm 1300 x 700 x 698 1300 700 698 1300 x 700 x 698 Dimensions HxLxP Peso a Potencia nominal e reducida Nominal output and Reduced output El consumo de pellets pueden variar seg n el tipo de pellet utilizado Pellet consumption can vary according to the type of pellets used 133 DOMUSFIRE C29 C35 C39
178. he products at any time without notice Boiler installation use and maintenance operations must comply with the requirements given in this manual as well as the European National Regional Provincial and Municipal laws and regulations The drawings measurements diagrams and any other configurations are given only by way of example This manual is intended for the user of the heating hot water system and is an integral part of the product make sure it always stays with the unit even if sold transferred to another owner or installed in another place so that it can be consulted at any time If lost or damaged ask the authorised Service Centre for a copy so that the unit always has its own manual N This symbol indicates the presence of an important message failure to pay attention to it can result in serious damage to the boiler and even injury Pay special attention to words in bold face 1 3 Safety rules Read the use and maintenance manual before installing lighting and servicing the boiler installation the electrical connection testing and maintenance carried out by a qualified and or authorised technician Connect the boiler to an approved flue via an inspectionable terminal The connection of more than one unit is possible only if allowed by the local regulations and by the flue contro authority Connect the boiler to the extraction system by means of a pipe or air inlet from outside Con
179. he unit that may become very hot during operation The boiler must be disconnected from the power supply and cold before carrying out any maintenance Ensure an ambient temperature of between 0 C and 35 C in the place of installation avoiding too high air humidity e g in the presence of laundry hanging out to dry Do not handle easily flammable or explosive substances near the boiler while it is in operation Do not modify safety or adjustment devices without the manufacturer s express permission Any tampering and or unauthorised replacements with non original parts of the boiler can create a risk for the user s safety and relieves the manufacturer of any civil or penal liability Only use original replacement parts recommended by the manufacturer In case of malfunction the boiler can be switched on again only after eliminating the cause of the problem in any case do not disable the safety systems In case of fire turn the heating system off disconnect the power and use adequate systems to extinguish the flames and or call the Fire Department Clean the brazier regularly at every lighting and or pellet reloading A Avoid the formation of smoke and unburned products during lighting and or normal operation an excessive amount of unburned pellets in the brazier must be removed manually before proceeding with lighting Service the boiler at least once a year planning it in advance with the personnel of the authorised Service C
180. hnique autoris afin qu il reste toujours avec l appareil Ce symbole indique la pr sence d un message important auquel pr ter une attention particuli re car la non observation des instructions peut entra ner de s rieux dommages la chaudi re et aux personnes Une information n cessitant une attention particuli re est mise en vidence par un texte crit en Caract res gras 1 3 Consignes de s curit Lire attentivement ce manuel avant l installation l utilisation et l entretien de la chaudi re L installation les raccordements lectriques l essai et l entretien sont r serv s un technicien qualifi et ou agr Raccorder la chaudi re un carneau homologu travers un embout pouvant tre contr l il est possible de raccorder plusieurs appareils uniquement si les normes locales et si l organisme de contr le du carneau l autorisent Raccorder la chaudi re de l ext rieur la bouche d aspiration travers un tuyau ou une prise d air Raccorder la chaudi re une prise de courant homologu e de 230 V 50 Hz V rifier que l installation lectrique et les prises soient en mesure de supporter l absorption maximum de l appareil figurant sur l tiquette et sur le manuel La fiche d alimentation doit tre port e de main Raccorder l appareil l installation de chauffage il ne peut en aucun cas tre utilis sans le branchement hydraulique et sans la charge en ea
181. i prodotti di combustione deve garantire un adeguata diluizione dei prodotti ed essere posizionato al di fuori della zona di reflusso deve essere privo di mezzi meccanici di aspirazione A Lo scarico diretto dei prodotti della combustione deve essere previsto tetto ed vietato verso spazi chiusi anche a cielo libero 2 5 Controllo posizione braciere e turbolatori Prima di accendere la caldaia e importante controllare che il braciere sia in posizione corretta ovvero alloggi negli appositi incastri Inoltre controllare che il dispositivo scuoti turbo latori sia a riposo ovvero in posizione inferiore Una posizione errata del braciere e o turbo latori comporta malfunzionamenti ed un eccessiva formazione di polveri ed incombusti A Ad ogni accensione dell apparecchio controllare la corretta posizione del braciere del dispositivo di scuotimento turbolatori 2 6 Collegamento elettrico Collegare il cavo di alimentazione elettrica da una parte alla presa posteriore della stufa e dall altra su una presa elettrica a parete La tensione fornita dall impianto deve corrispondere a quella indicata sulla targhetta di identificazione della stufa e nel paragrafo relativo ai dati tecnici di questo manuale Nel periodo di inutilizzo della stufa consigliabile togliere il cavo di alimentazione dalla stessa differenziale secondo le Norme vigenti Assicurarsi che l impianto elettrico sia a norma provvisto della messa a terra e
182. ia 1 8 Placa de identificaci n 1 9 Puesta fuera de servicio de la caldera 1 10 Pedido de reparaciones y recambios 2 TRANSPORTE E INSTALACI N 2 1 Condiciones de suministro transporte almacenaje 2 2 Lugar de instalaci n emplazamiento y prevenci n de incendios 2 3 Toma de aire 2 4 Salida de los humos de combusti n 2 4 1 Tipos de instalaci n 2 5 Control de la posici n del brasero y de los turbuladores 2 6 Conexi n el ctrica 2 7 Esquema el ctrico 2 8 Esquema el ctrico para instalaci n por zonas 2 9 Conexiones hidr ulicas 2 9 1 Carga de agua en la instalaci n 2 9 2 Caracter sticas del agua de la instalaci n 2 9 3 Instalaci n de agua sanitaria 2 9 4 Esquemas hidr ulicos de la caldera 2 10 Emergencias 3 SEGURIDAD DE LA CALDERA 3 1 Distancia m nima de materiales inflamables 3 2 Dispositivo de seguridad en la salida de humos 3 3 Seguridad contra sobrepresiones en la c mara de combusti n 3 4 Sobrecalentamiento termostatos 3 5 Seguridad contra el retorno de la llama al conducto de alimentaci n de pellets 3 6 Dispositivo el ctrico de sobrecorrientes 3 7 Seguridad contra sobrepresiones en el circuito hidr ulico 3 8 Fallo del ventilador de extracci n de humos protecci n contra 4 USO DE LA CALDERA 4 1 Introducci n 4 2 Descripci n del panel de mandos 4 3 Encendido 4 3 1 Control antes del encendido 4 3 2 Puesta en marcha 4 4 Funcionamiento 4 4 1 Modificaci n de la consigna de temperatura
183. icht verschlossen sein Das elektrische Kabel muss korrekt angeschlossen sein und der Schalter an der Kesselr ckseite muss auf ON 1 stehen Die Sperrventile an Vor und R cklauf m ssen ge ffnet sein Den Druck im Wasserkreis kontrollieren 115 DOMUSFIRE C29 C35 C39 COLA Wenn der Kessel zum ersten Mal in Betrieb genommen wird alle brennbaren Teile A Betriebsanleitung Etikett aus dem Feuerraum nehmen Wird der Kessel nach l ngerem Stillstand eingeschaltet m ssen die eventuell schon lange im Beh lter liegenden Pelletreste durch neue Pellets ersetzt und die Brennkammer vollst ndig gereinigt werden da dieser Brennstoff feucht und nicht mehr zur Verfeuerung geeignet ist 4 3 2 Z ndvorgang Zum Einschalten des Kessels die Taste P4 Sekunden lang dr cken Auf dem Display erscheint die Anzeige START Diese Phase ist automatisch und wird von der elektronischen Regelung gesteuert ohne die Parameter andern zu k nnen Alternativ hierzu kann der Kessel eingeschaltet werden indem die Tasten P4 und P5 gleichzeitig 3 Sekunden lang gedr ckt werden Auf dem Display erscheint die Meldung WARTEN AUF BEDARF Auf diese Weise wird der Kessel in einen Wartestatus versetzt und die Einschalt Startphase nur ausgef hrt wenn eine W rmeanforderung vorliegt zum Beispiel zum Erhitzen des Wassers oder f r die Warmwasserbereitung sofern verf gbar 1436 SECS El nSCHAL Dialogfenster Wassertemperatur Taste P4 Der
184. ico 146 DOMUSFIRE C29 C35 C39 COLA A la primera puesta en marcha quite de la c mara de combusti n de la caldera todos los elementos A que se puedan quemar instrucciones etiqueta Antes de encender la caldera tras una inactividad prolongada puede ser necesario quitar los restos de pellets que hayan quedado en el dep sito porque este combustible si se humedece no es id neo para la combustion ni asegura una buena limpieza de la camara 4 3 2 Puesta en marcha Para encender la caldera pulse la tecla P4 durante 3 segundos en pantalla aparece la indicaci n START Esta fase es autom tica y est totalmente gestionada por el control electr nico sin posibilidad de modificar los par metros Como alternativa se puede encender la caldera presionando al mismo tiempo las teclas P4 y P5 durante 3 segundos En la pantalla aparece la indicaci n ESPERA DEMANDA Con esta modalidad la caldera queda en estado de espera y se enciende solo si hay una demanda de calor ya sea de calefacci n o de agua caliente sanitaria si est disponible Ventana de di logo Temperatura agua Tecla P4 La caldera realiza las diversas fases de puesta en marcha de acuerdo con los niveles y tiempos programados hasta llegar a la condici n de trabajo si no ha surgido ninguna anomal a o alarma El proceso es el siguiente estado duraci n dispositivos condiciones para pasar al estado siguiente encendedor Se sin
185. ico autorizzato n caso di anomalie di funzionamento la caldaia pu essere riaccesa solo dopo avere ripristinato la causa del problema in caso contrario contattare il servizio di Assistenza La ditta produttrice non responsabile di inconvenienti rotture o incidenti dovuti al mancato rispetto o alla mancata applicazione delle indicazioni soprascritte e contenute nel presente manuale 1 4 Descrizione tecnica La caldaia funziona esclusivamente a pellet e permette una facile installazione con l impianto di riscaldamento e sanitario sistemi di controllo automatici di cui dotata garantiscono una resa termica ottimale ed una completa combustione inoltre sono presenti dei sistemi di sicurezza atti a garantire un funzionamento sicuro sia per i componenti interni sia per l utente Tale apparecchio deve essere utilizzato per il solo riscaldamento dell acqua ad una temperatura inferiore a quella di ebollizione L apparecchio installato a Norma funziona con qualsiasi condizione climatica esterna e comunque in condizioni critiche vento forte gelo ect possono intervenire i sistemi di sicurezza che spengono la caldaia 7 DOMUSFIRE C29 C35 C39 COLA Dati tecnici caldaia A Caldaia a pellet Heating Boiler Modello DOMUSFIRE DOMUSFIRE Model C29 c39 Pellet di legno Wood pellet UNI EN14961 2_classe A1 Heating input e pm eran STE Water heating output Efficiency Fuel consumption rT H nm EE 0 005 0 040 m 0 0
186. il camino sia dotato di camera ispezionabile per la ee ana raccolta di materiali solidi Distanza minima min 100 cm ed eventuali condense collocato sotto l imbocco del canale da fumo CANALE o RACCORDO da FUMO condotto o elemento di collegamento tra apparecchio e camino per l evacuazione dei prodotti della combustione Requisiti tecnici CANALE non deve attraversare locali nel quali vietata l installazione di apparecchi da combustione vietato l uso di tubi metallici flessibili o in fibro cemento vietato l impiego di elementi in contro pendenza nei tratti orizzontali devono avere andamento con pendenza minima del 396 verso l alto la lunghezza del tratto orizzontale deve essere minima e non maggiore di 3 m il numero di cambi direzione senza il raccordo a T non deve essere maggiore di 3 con cambio di direzione 90 usare al max 2 curve con lunghezza in proiezione orizzontale non maggiore di 2 m il canale da fumo deve essere a sezione costante e permettere il recupero della fuliggine COMIGNOLO dispositivo posto alla sommit del camino atto a facilitare la dispersione in atmosfera dei prodotti della combustione Requisiti tecnici COMIGNOLO avere sezione equivalente a quella del camino avere sezione utile non minore del doppio di quella interna del camino deve impedire la penetrazione di pioggia e di corpi estranei ed in ogni condizione atmosferica assicurare lo scarico de
187. ileva l assenza di flusso d aria comburente che tramite il controllo elettronico interrompe il funzionamento del motore rotazione coclea avvisando l utente dell anomalia con un messaggio sul pannello comandi AL8 MANCA DEPRESS o AL9 TIRAGGIO INSUFF 3 3 Sicurezza sovrapressione in camera di combustione Eventuali e o improvvise sovrapressioni dei fumi di combustione all interno della camera e dei condotti di evacuazione dei fumi vengono scaricati attraverso l apertura delle valvole di sicurezza poste sopra la porta cenere Durante il normale funzionamento queste valvole sono chiuse dal proprio peso e dalla depressione della camera e garantiscano la tenuta contro l eventuale uscita dei fumi A Controllare periodicamente la chiusura lo stato di integrit del dispositivo e il relativo funzionamento 3 4 Surriscaldamento termostati di sicurezza Sulla parete inferiore del serbatoio e precisamente sul convogliatore del pellet e sulla parte pi alta della termocamera sono posizionate due sonde di temperatura collegate ai rispettivi termostati di sicurezza che in caso di eccessivo riscaldamento disattivano automaticamente l alimentazione del pellet In tal caso l estrattore e o ventilatori continuano a funzionare consentendo il rapido raffreddamento dell apparecchio L anomalia viene visualizzato sul pannello comandi con il messaggio AL 7 SICUREZ TERMICA In caso di intervento operare come segue Lasciare raffreddare la cald
188. imo controllo per la convalida della garanzia su tutti i prodotti a pellet venduti ed installati nel territorio italiano Vi elenchiamo le operazioni da eseguire ai fini della Convalida in oggetto 1 leggere il Certificato di Garanzia e allegare al manuale d uso manutenzione in dotazione alla stufa 2 leggere attentamente il manuale d uso e manutenzione prima di installare usare e manutentare la stufa 3 controllare la presenza del bollino adesivo di Convalida Primo Controllo gratuito e conservarlo in luogo sicuro tale adesivo sar applicato sul rapporto d intervento del Centro di assistenza autorizzato assieme al bollino siglato con la lettera A verde presente nel Certificato di Controllo in dotazione alla stufa 4 fare installare la stufa da un tecnico qualificato rispettando le norme vigenti locali e nazionali e le prescrizioni presenti nel manuale d uso e manutenzione 5 chiedere l intervento di Primo Controllo gratuito al Centro assistenza di zona autorizzato 6 al termine dell operazione di controllo ed esito positivo il Centro di assistenza provvedr alla compilazione completa in ogni sua parte del rapporto d intervento in triplice copia e precisamente Produttore Cliente e Centro di Assistenza tale documento nella copia da inviare al Produttore dovr riportare il bollino di convalida Primo Controllo il bollino A presente nel Certificato di Controllo della stufa e la firma di accettazione del Cliente 7 il Centro di assist
189. io da una persona responsabile della loro sicurezza I bambini devono essere sorvegliati e accertarsi che non giochino con l apparecchio e nel locale d installazione Posizionare il cavo di alimentazione elettrica ed eventuali cavi di sensori esterni in modo da evitare il contatto con le parti calde dell apparecchio E vietato il funzionamento dell apparecchio con la porta fuoco e o la porta del cassetto cenere aperte Evitare di chiudere o ridurre le sezioni delle aperture di ingresso dell aria comburente e di scarico dei fumi La caldaia non deve essere usata come inceneritore essa deve essere utilizzata solo ed esclusivamente per riscaldare l acqua dell impianto di riscaldamento e o sanitario utilizzando come unico combustibile pellet di legno aventi le caratteristiche descritte nel presente manuale Non impiegare liquidi o sostanze infiammabili per l accensione La caldaia non deve essere usata come inceneritore di rifiuti E vietato manipolare sostanze facilmente infiammabili o esplosive nelle vicinanze della caldaia durante il suo funzionamento Evitare il contatto diretto con le parti dell apparecchio che durante il funzionamento possono surriscaldarsi Prima di ogni manutenzione staccare l alimentazione elettrica dalla caldaia ed operare solo con caldaia fredda Garantire nel locale d installazione una temperatura ambiente comprese tra 0 C e 35 evitando umidit dell aria troppo elevata per es con l
190. ion detects a pressure below or bringing it to the normal operating PRESSURE 7he system is stopped above the fixed limits value The safety thermostat has ALA Occurs in case of cutting in detected a temperature above i or excessive SAFETY heating chamber water the setting threshold due i to Reset the relevant safety temperature safety thermostat overheating of the heating H20 The system is stopped chamber water blocking dE pressing the reset gearmotor operation AL b Occurs when the gearmotor AUG TRIAC works continuously and for more SS en Reinstatement operations must than 60 sec 9 be carried out by a service centre ERROR The system is stopped stuck Occurs in case of water T Al c detection probe _ WATER fault BE le disennmsetaddtram Reinstatement operations must displaying T H20 0 the de d be carried out by a service centre PROBE The shutdown procedure is activated ALd Occurs when the water Check the cause of the problem temperature has exceeded the Occurs when ne temperature restoring the temperature by HOT ee probe in the heating chamber fixed limits detects value above 92 bringing it to the normal operating WATER The system is stopped value a Reset attempt in shutdown stage Alarm reset is possible only after AWAITING 000075 on relighting the boile Reset attempt in shutdown st Al t ble only aft COOL down 9 with boiler hot in cooling stage shutdow
191. ion erfordert den Einsatz eines externen Thermostats oder eines Wassertemperaturf hlers der die Brauchwassertemperatur im Boiler misst Wenn die Temperatur unter die Temperatur des eingestellten SOLLWERTS sinkt setzt sich die Warmwasserbereitung in Betrieb auf dem Display des Kessels erscheint die Meldung WWB BOILER und die mit dem Wasserhahn gekennzeichnete LED leuchtet bis der Bedarf erf llt ist Wenn der Kessel sich in der Phase WARTEN AUF BEDARF befindet wird er automatisch eingeschaltet und in BETRIEB versetzt Sobald das Wasser in der Heizkammer die Betriebstemperatur erreicht hat wird die Zuleitung von Wasser zum Boiler aktiviert Wenn die Temperatur des Boiler SOLLWERTS erreicht ist leitet der KESSEL die Restw rme etwa 2 Minuten lang zur Heizanlage und wenn kein weiterer W rmebedarf vorliegt schaltet er je nach Einstellung auf WARTEN AUF BEDARF oder auf MODULATION siehe Abschn 4 6 4 Wenn der Kessel AUSGESCHALTET ist wird er nicht eingeschaltet und liefert kein Warmwasser 4 13 6 Anlage mit Pufferspeicher W rmespeicher Diese Installation erfordert den Einsatz eines externen Thermostats der die Wassertemperatur im Pufferspeicher misst Wenn die Temperatur unter die Temperatur des im externen Thermostat eingestellten SOLLWERTS sinkt wird auf dem Display des Kessels erscheint die Meldung WASSER PUFFER oder WASSER BOILER und die 2 LEDs die respektive mit dem Wasserhahn bzw mit dem Heizk rper gekennzeichnet sind leuchten auf
192. ionen zur CE kennzeichnung DOMUSFIRE C29 C35 C39 COLA 1 ALLGEMEINE HINWEISE 1 1 Vorwort Verehrter Kunde Wir danken Ihnen f r das Vertrauen das Sie uns mit dem Kauf dieses Ger ts entgegengebracht haben Bitte lesen und befolgen Sie diese Installations Gebrauchs und Wartungsanleitung um die Produkteigenschaften optimal nutzen zu k nnen 1 2 Nachschlagen im Handbuch Der Hersteller beh lt sich vor die technischen Merkmale und das Design der Produkte jederzeit und ohne Vorank ndigung zu ndern Installation Bedienung und Wartung des Kessels m ssen den in diesem Handbuch enthaltenen Vorschriften sowie den europ ischen nationalen regionalen und kommunalen Gesetzen und Normen entsprechen Alle Abbildungen Ma e bersichtszeichnungen sowie s mtliche sonstigen Angaben in dieser Druckschrift dienen nur zur Veranschaulichung und sind nicht verbindlich Diese Betriebsanleitung ist f r den Benutzer der Heizungs Warmwasserbereitungsanlage bestimmt und bildet einen wesentlichen Bestandteil des Produkts sie muss immer beim Ger t bleiben und diesem bei Verkauf Ubereignung oder Standortverlegung folgen damit jederzeit darin nachgeschlagen werden kann Bei Verlust oder Besch digung ist beim Vertragskundendienst eine Kopie anzufordern damit das Ger t stets mit einer Betriebsanleitung ausgestattet ist Dieses Symbol weist auf eine wichtige Mitteilung hin die besondere Aufmerksamkeit erfordert denn die Nichtbeachtung der Angabe
193. izia contenitore cenere Direttamente sotto il braciere porta braciere collocato il contenitore cenere Per procedere alla sua pulizia e necessario aprire la porta cenere ed aspirare con un idoneo aspiratore la cenere presente al suo interno ed eventuali residui di combustione Dopo la pulizia necessario chiudere lo sportello La pulizia del contenitore cenere pu essere eseguita ogni 2 3 giorni in funzione dell utilizzo della caldaia 29 DOMUSFIRE C29 C35 C39 COLA 5 3 Pulizia estrattore fumi e della camera di combustione Almeno una volta all anno si deve procedere alla pulizia della camera di combustione rimovendo tutti i residui di combustione dai tubi fumi interni e dal percorso fumi Per eseguire tale operazione necessario rimuovere il coperchio superiore della caldaia il coperchio della termocamera e lo sportello inferiore d ispezione svitando le necessarie viti di fissaggio e procedere quindi alla pulizia dei turbo latori e dei tubi fumo interni alla camera Inoltre importante pulire l estrattore fumi collocato posteriormente il collettore inferiore fumi che si accede attraverso il vano dello sportello d ispezione posto dietro il cassetto cenere Ogni 3 4 mesi pulire le pareti interne della camera di combustione e del collettore superiore fumi con opportune attrezzature pennelli spazzole ed eventualmente sostituire le pareti in vermiculite in quanto considerati materiale di normale usura La caldaia ogni 1800 ore di
194. kt m ssen von einer autorisierten Kundendienststelle durchgef hrt werden Wird ausgel st wenn der z Nach der Ursache f r das Problem AL E Wasserdruck nicht innerhalb der f r Wird ausgel st d der suchen den Druck im Kreis wieder WASSERDR den korrekten Betrieb Druckmessumformer im Wasserkreis erstellen und auf den f r den einen Druck unter oder ber den UCK vorgeschriebenen Werte liegt Grenzwerlenimissf normalen Betrieb vorgeschriebenen Das System wird gestoppt geg i Wert bringen Es findet im Fall der Intervention der Der berhitzungsschutz eine Nach der Ursache f r die AL A Sicherheits Thermostat auf dem Temperatur oberhalb der Schwelle Uberhitzung suchen SICHERUNG esse Temperatur der thermischen Sollwert f r eine Erw rmung des Den Betrieb des von der Kammer mit T gt 95 C Wassers von der Warmekammer Uberhitzung betroffenen Thermostats H20 System gestoppt wird siii durch Dr cken der Reset Taste wieder herstellen AL b Wird ausgel st wenn der e Die Vorgange zur Wiederherstellung FEHLER Getriebemotor in Dauerbetrieb und 018 Regelung ma festgestellt dass des Kesselbetriebs m ssen von einer das Steuerrelais des Getriebemotors Ge TRIAC anger als 60 Sek l uft defekt ist Kontakte verklebt autorisierten Kundendienststelle SCHNECKE Das System wird gestoppt durchgef hrt werden ALc Dieser Alarm wird ausgel st wenn der E gt Die Vorg ng
195. l s en phase d allumage et ou de fonctionnement normal l accumulation excessive de granul s non br l s dans le foyer doit tre limin e manuellement avant tout nouvel allumage Proc der r guli rement la maintenance de la chaudi re au moins une fois par an en programmant la visite d un technicien avec le centre d assistance agr Encas de dysfonctionnement il ne sera possible de rallumer la chaudi re qu apr s avoir r solu le probl me dans le cas contraire contacter le service apr s vente La soci t Cola s r l d cline toute responsabilit pour les inconv nients les ruptures ou les accidents caus s par l inobservation ou l inapplication des indications contenues dans ce manuel 1 4 Description technique La chaudi re est aliment e exclusivement avec des granul s de bois et peut facilement tre raccord e une installation de chauffage et d eau chaude sanitaire Les syst mes de contr le automatiques qui quipent la chaudi re assurent un rendement thermique optimal et une combustion compl te Des syst mes de protection garantissent la s curit des composants et de l utilisateur Cet appareil permet uniquement de chauffer l eau une temp rature inf rieure celle d bullition Si la chaudi re est install e conform ment aux normes en vigueur elle fonctionnera dans n importe quelle condition climatique ext rieure m me critique vent fort gel etc car les syst mes de s curit dont e
196. l imm diat en indiquant la condition de fonctionnement des dispositifs reli s celui ci des pages cran sont ensuite successivement propos es pour le monitorage 89 DOMUSFIRE C29 C35 C39 COLA 4 6 5 Menu 05 R glages de l installateur La s lection de cette option est r serv e uniquement au technicien agr de l assistance COLA comp tent les modifications ventuelles faites de mani re fortuite peuvent s rieusement endommager La modification des param tres techniques du menu 05 doit tre effectu e par un professionnel agr et A la chaudi re et d gage la soci t COLA de toute responsabilit 4 7 Thermostat chronothermostat externe Pour utiliser un thermostat externe faire appel a un technicien agr et suivre les instructions suivantes teindre l appareil en agissant sur l interrupteur g n ral plac l arri re de la chaudi re et d brancher le cordon d alimentation d monter les panneaux lat raux les flancs pour acc der l lectronique embarqu e en faisant r f rence au sch ma lectrique brancher les deux fils du thermostat sur leurs bornes correspondantes TERM de la carte remonter le tout et v rifier si la chaudi re fonctionne correctement Pour chaque pr s lection les fonctions du menu ne varient pas et la signalisation du raccordement se fait par l allumage de la LED segment sur la barre d tat l cran Si le thermostat a atteint la bonne temp
197. la chaudi re selon qu elle est Aa teinte ou allum e ON OFF VERROUILLAGE D verrouille la chaudi re et l teint OFF D verrouillage nouveau Permet de quitter le menu de programmation tout moment de la PROGRAMMATION modification Les modifications sont m moris es EE Diminue puissance ou valeur de Temp rature de 5 Diminution de la FONCTIONNEMENT TEINT temp rature d intervention du thermostat Mrs CONSIGNE SET 15 de l eau du ballon sanitaire si valid sanitaire e Augmente la puissance ou la valeur de la d Temp rature de Augmentation Niveau de S 6 de la puissance FONCTIONNEMENT ETEINT temp rature d intervention du thermostat puissance CONSIGNE SET 1 5 de l eau du ballon sanitaire si valid sanitaire La figure ci contre fournit l explication des indicateurs d tat sur la partie gauche de l cran L activation l cran d un des segments signale la mise en service du dispositif correspondant suivant la liste ci contre 4 3 Allumage 4 3 1 Contr le avant l allumage Avant d allumer la chaudi re v rifier les points suivants s assurer d avoir bien lu et compris les indications contenues dans le manuel s assurer que le r servoir granul s est rempli s assurer que la chambre de combustion est propre s assurer que le brasier est totalement libre propre sans d p ts et correctement en place v rifier la fermetur
198. le persone Una voce che richiede particolare attenzione evidenziata in con il testo in grassetto 1 3 Norme di sicurezza Leggere il manuale d uso e manutenzione prima di installare accedere e manutentare la caldaia Eseguire installazione collegamento elettrico collaudo e manutenzione da un tecnico qualificato e o autorizzato Collegare la caldaia ad una canna fumaria a Norma tramite un terminale ispezionabile Il collegamento di pi apparecchi pu avvenire solo se viene contemplato dalle Norme locali e concesso dall Organismo di controllo della canna fumaria Collegare la caldaia all aspirazione tramite un tubo o presa d aria dall esterno Collegare la caldaia ad una presa elettrica a Norma tensione 230 V 50 Hz Verificare che l impianto elettrico e le prese abbiano la capacit di sopportare l assorbimento massimo dell apparecchio riportata sull etichetta e sul presente manuale La spina di alimentazione deve essere facilmente accessibile Collegare l apparecchio all impianto di riscaldamento esso non pu in nessun caso essere usato senza l allacciamento idraulico e senza il caricamento dell acqua nella termocamera e nell impianto E vietato l uso di questo apparecchio a persone inclusi i bambini con limitazioni delle abilit fisiche sensoriali e mentali o con scarsa esperienza e o con conoscenze non adeguate a meno che non siano sorvegliate ed istruite nell uso dell apparecch
199. le solido parte 2 Norma CEI EN 60335 1 Sicurezza degli apparecchi elettrici d uso domestico e similare parte Norma CEI EN 60335 2 102 Sicurezza degli apparecchi elettrici d uso domestico e similare parte 2 Norma CEI EN 55014 1 Resistenza elettromagnetica Requisiti per elettrodomestici attrezzi elettrici e apparecchi elettrici simili Parte 1 Emissione di disturbo Norma CEI EN 55014 2 Resistenza elettromagnetica Requisiti per elettrodomestici attrezzi elettrici e apparecchi elettrici simili Parte 2 Immunit Norma famiglia di prodotti Norma CEI EN 61000 3 2 Limiti per le emissioni di corrente armonica Corrente ingresso lt 16 A per fase Norma CEI EN 61000 3 3 Limitazione delle fluttuazioni di tensione e del flicker in sistemi di alimentazione in bassa tensione per apparecchiature con corrente nominale lt 16 Norma CEI EN 62233 Metodi di misura per campi elettromagnetici degli apparecchi elettrici di uso domestico e similari con riferimento all esposizione umana Norme DIN plus 51731 UNI EN14961 2 Norm M 7135 Norme riguardanti le specifiche e la classificazione del pellet 1 8 Targa di identificazione La targa di identificazione amp visibile sulla superficie interna dello sportello serbatoio pellet o sulla parete posteriore della caldaia Su di essa sono riportati tutti i dati tecnici presenti nella tabella del par 1 4 1 9 Messa fuori servizio della caldaia Nel
200. lejas o grandes 2 9 3 Instalaci n de agua sanitaria Para conectar la caldera a un sistema de agua sanitaria se aconseja llamar a un t cnico autorizado a fin de que optimice el conexionado hidr ulico y las prestaciones de todo el sistema sin comprometer el funcionamiento del equipo Para la conexi n al circuito de agua sanitaria es necesario pedir uno de los siguientes opcionales bomba de AS en el colector de ida con los respectivos tubos de conexi n para montar dentro de la caldera o bien bomba de AS intercambiador de placas y tubos de conexi n para montar dentro de la caldera o una v lvula de 3 v as para montar fuera de la caldera 141 DOMUSFIRE C29 C35 C39 COLA Una vez terminada la conexi n del agua sanitaria se debe entrar en el men t cnico del control y seleccionar el tipo de circuito Los dispositivos para el agua sanitaria implementados INTERCAMBIADOR SANITARIO ACUMULADOR DEP SITO DE INERCIA o ACUMULADOR SANITARIO se indican en la pantalla con uno de los mensajes ilustrados m s abajo al producirse la conmutaci n de calefacci n a agua sanitaria y permanecen hasta que termina la demanda de agua caliente sanitaria desde el termostato o el flujostato 2 9 4 Esquemas hidr ulicos de la caldera UE E Esquema hidr ulico de la caldera de pellets con bomba Caldera de pellets Camara t rmica pellets LEYENDA Q Llave de descarga Sensor de presi n man metro
201. ler la temp rature souhait e I Quand la temperature de l eau a atteint la valeur pr r gl e ou la AFF THE temp rature des fum es a atteint la valeur maxi pr r gl e la IL puissance est automatiquement amen e a la valeur minimale en of A condition de MODULATION EErP EAU Quand la temp rature des fum es atteint une valeur maxi pr r gl e le panneau de commande affiche le message MODULER F et la chaudi re lance la proc dure de modulation de la flamme sans que l utilisateur n intervienne si la temp rature d passe 280 l alarme AL3 HOT FUMEES se d clenche et la chaudi re valide la proc dure d extinction 4 4 2 Remise en marche partir du mode VEILLE STAND BY Lorsque la fonction VEILLE et son thermostat d ambiance ou du ballon sont valid s la chaudi re s teint apr s quoi elle se met en condition de refroidissement en amenant la vitesse d extraction des fum es la valeur pr r gl e pour le gt nettoyage du brasier Le red marrage survient des que la OK AEEEREE temp rature de l eau a atteint la valeur de CONSIGNE SET m A d 4 4 3 Nettoyage du brasier Pendant le fonctionnement normal a intervalles pr d finis la a modalit NETTOYAGE BRASIER est valid e pour une dur e 1436 pr d finie et 558 dure Puissance nEEEOYAS pr d finie LI 85 DOMUSFIRE C29 C35 C39 COLA 4 4 4 Eau chaude sanitaire avec changeur rapide En cas de demande d
202. let Boiler with DHW plate heat exchanger _07 2012 Pellet boiler OUT Control system DHW DELIVERY male 1 2 Pellet heating RETURN DHW male 1 chamber DELIVERY Heating male 1 Water supply F1 2 Water overpressure discharge F1 2 KEY 1 Drain cock 11 Flow switch Pressure gauge pressure sensor a Plate heat exchanger for DHW 4 Circulating pump Circuit balancing valves 5 Membrane expansion tank 4 Automatic thermostatic valve 6 Shutoff valve cock Safety sensor T gt 85 C D Non return valve Water temperature sensor Circuit heating chamber vent Circuit pressure sensor 9 Pressure relief valve max 3 bar H valves to be included in the system during installation not supplied with the unit 40 Pressure relief valve P max 6 bar 2 10 Emergency Suitable fire prevention devices should be arranged for any eventuality In case of a fire proceed as follows Immediately disconnect the power plug Extinguish the fire using suitable fire extinguishers Call the fire department immediately Do not use jets of water to extinguish the fire 49 DOMUSFIRE C29 C35 C39 COLA 3 BOILER SAFETY 3 1 Safety distance from flammable materials To prevent the risk of fire unit positioning must respect a minimum distance from flammable materials according to that given in the technical table of the manual and on the data plate
203. liabile disporre di idonei dispositivi antincendio Se si manifesta un incendio procedere come segue Scollegare immediatamente la presa di corrente Spegnere tramite l uso di estintori Richiedere l immediato intervento dei vigili del fuoco Evitare di spegnere il fuoco con l uso di getti d acqua a piastre sanitario 07 2012 A MANDATA Riscaldamento moschlo 1 C MANDATA Sanitario moschio 1 2 B RITORNO Riscaldamento moschlo 1 F Scorlco acqua In sovrapres F1 2 A C gt COLA 18 DOMUSFIRE C29 C35 C39 COLA 3 SICUREZZE DELLA CALDAIA 3 1 Distanza di sicurezza da materiali infiammabili L apparecchio va collocato ad una distanza minima perimetrale da materiali infiammabili al fine di evitare pericoli di incendio secondo le indicazioni presenti nella tabella tecnica del manuale e riportate nella targa dello stesso Porre attenzione alla tipologia del pavimento e del soffitto copertura del locale d installazione per materiali delicati ed infiammabili si raccomanda l utilizzo di adeguati pannelli o diaframmi termici vedere par 2 2 3 2 Sicurezza scarico fumi Nel normale funzionamento la camera di combustione in depressione garantendo la tenuta da eventuali perdite di fumo nell ambiente Nel caso in cui non si raggiunge un certo valore di vuoto o lo scarico di uscita dei fumi ostruito il vacuostato capta la mancanza di depressione all interno della camera di combustione oppure il debimetro r
204. lides Norme UNI EN303 5 2004 Norme fixant la terminologie les exigences les tests et le marquage relatifs aux Chaudi res a combustibles solides avec alimentation manuelle et automatique Norme UNI 10412 2 2009 Norme fixant les exigences de s curit des installations utilisant des appareils pour le chauffage domestique aliment s par des g n rateurs de chaleur aliment s par un combustible solide partie 2 Norme CEI EN 60335 1 Appareils lectrodomestiques et analogues S curit Partie 1 Norme CEI EN 60335 2 102 Appareils lectrodomestiques et analogues S curit Partie 2 Norme CEI EN 55014 1 R sistance lectromagn tique Exigences pour les appareils lectrom nagers outillages lectriques et appareils analogues Partie 1 Emission Norme CEI EN 55014 2 R sistance lectromagn tique Exigences pour les appareils lectrom nagers outillages lectriques et appareils analogues Partie 2 Immunit Norme famille de produits Norme CEI EN 61000 3 2 Limites pour les missions de courant harmonique courant appel par les appareils inf rieur ou gal a 16 A par phase Norme EN 61000 3 3 Limitation des variations de tension des fluctuations de tension et du papillotement dans les r seaux publics d alimentation basse tension pour les mat riels ayant un courant assign inf rieur ou gal a 16 A par phase et non soumis a un raccordement conditionnel Norme EN 62233
205. lle est quip e arr teront son fonctionnement extinction en cas de probl me 69 DOMUSFIRE C29 C35 C39 COLA Caract ristiques techniques de la chaudi re T EE A Chaudi re a granul s Heating Boiler uel Model DOMUSFIRE DOMUSFIRE DOMUSFIRE Mod le 29 C35 C39 EEN Granul s de bois Wood pellet UNI EN14961 2 classe A1 Puissance thermique introduct kW 29 0 64 344 64 383 64 Heating input Puissance thermique utile kW 274 5 78 324 5 78 34 9 578 Water heating output Rendement DEAR 94 45 90 14 94 18 90 14 91 32 90 14 Efficiency 0 005 0 040 0 007 0 040 0 009 0 040 Consommation horarie 6 6 18 8 6 7 18 8 6 7 18 8 Emission CnHm at reference 10 O gt Emissions NOx 10 Emission NOx at reference 10 gt Emissions de poussi res 10 Emission dust at reference 10 O 2 Emissions CO 13 O2 Emission CO at reference 13 Emissions CnHm 13 146 7 116 4 Fuel consumption 147 1 116 4 130 2 116 4 Emissions CO 10 O2 Emission CO at reference 1096 O2 23 6 9 5 24 5 9 5 0 005 0 029 0 006 0 029 24 1 9 5 0 004 0 029 Emission CnHm at reference 13 O gt Emissions CnHm 1096 4 8 13 78 4 9 13 78 107 84 6 94 7 84 6 17 2 6 9 17 8 6 9 19 22 12 69 19 86 12 69 Emissions NOx 13 O MA 106 8 84 6 Emission NOx at reference 13 O Emissions de
206. lore residuo all impianto di riscaldamento per circa 2 minuti e poi se non c ulteriore richiesta si pone in ATTESA RICHIESTA o in MODULAZIONE a seconda delle impostazioni vedi prg 4 6 4 Se la caldaia nello stato SPENTO non si accende e non fornisce il servizio 4 4 6 Impianto con puffer accumulatore di calore Questo tipo di installazione richiede l utilizzo di un termostato esterno che misuri la temperatura dell acqua del puffer Quando la temperatura si abbassa al di sotto della temperatura di SET impostata nel termostato esterno nel display della caldaia compare la scritta ACQUA PUFFER ACQUA BOILER e si accendono i 2 LED indicati rispettivamente dal rubinetto e dal radiatore in quanto pu soddisfare l impianto di riscaldamento e sanitario Se la caldaia e nella fase di ATTESA RICHIESTA si accende automaticamente e si pone in LAVORO e raggiunta la temperatura di lavoro dell acqua nella termocamera si attiva la fornitura d acqua al puffer Quando la temperatura di SET del puffer soddisfatta la caldaia si pone in ATTESA RICHIESTA si raccomanda di impostare la funzione di STAND BY su ON vedi prg 4 6 4 Se la caldaia nello stato SPENTO non si accende e non fornisce il servizio 4 5 Spegnimento Per spegnere la caldaia sufficiente premere sul pulsante P4 per circa 2 secondi La coclea immediatamente arrestata e l estrattore fumi viene portato a velocit elevata facendo apparire sul display la scritta
207. lvulas de equilibrado del circuito 6 Vaso de expansi n con membrana A valvula termostatica automatica 6 Llave v lvula de corte Sensor de seguridad T gt 85 C D V lvula antirretorno Sensor de temperatura agua 8 Purgador borde c mara t rm circuito Sensor de presi n circuito 9 V lvula de seguridad Pm x 3 bar gt V lvulas que se colocan en la instalaci n 4 durante el montaje no entregadas con el 0 V lvula de seguridad Pm x 6 bar equipo 2 10 Emergencias Se aconseja tener a mano un dispositivo antiincendios adecuado Si se produce un incendio proceda del siguiente modo Desconecte inmediatamente el equipo de la corriente Apague el fuego con un extintor apropiado Llame r pidamente a los bomberos No intente apagar el fuego con chorros de agua 143 DOMUSFIRE C29 C35 C39 COLA 3 SEGURIDAD DE LA CALDERA 3 1 Distancia minima de materiales inflamables Para evitar incendios la caldera se debe instalar a una distancia de seguridad con respecto a cualquier material inflamable tal como se indica en la tabla t cnica del manual y en la placa de datos del equipo Tenga en cuenta el tipo de suelo y de techo o cubierta del local de instalaci n para materiales delicados o inflamables se recomienda utilizar paneles o diafragmas aislantes apartado 2 2 3 2 Dispositivo de seguridad en la salida de humos Durante el funcionamiento normal la c mara de combusti n est en depresi n
208. mbios quedan guardados Reducir Disminuye la potencia o la consigna 5 Sarah TRABAJO APAGADO del termostato del agua del Nivel de potencia Consigna temp ACS 1 5 acumulador sanitario si habilitado Aumenta la potencia la consigna 6 ana TRABAJO APAGADO del termostato del agua del Nivel de potencia Consigna temp ACS 1 5 acumulador sanitario si habilitado Contacto externo Crono La figura junto a estas lineas describe el significado de los simbolos de estado que se visualizan a la izquierda de la pantalla La aparici n de cada uno de estos s mbolos se ala la activaci n del dispositivo correspondiente Resistencia el ctrica Sinf n Extractor de humos Activaci n circuito ACS Activaci n circuito CALEFACCI N ALARMA 4 3 Encendido 4 3 1 Control antes del encendido Antes de encender la caldera Aseg rese de haber le do y comprendido el manual El dep sito debe estar cargado de pellets La c mara de combusti n debe estar limpia El brasero debe estar completamente vac o sin residuos de combusti n y correctamente ubicado en el portabrasero Compruebe el cierre herm tico de la puerta de la c mara de combusti n y del cenicero Verifique la conexi n del cable el ctrico y la conmutaci n a ON 1 del interruptor situado en la parte posterior de la caldera Compruebe la apertura de las v lvulas de corte en ida y retorno y la presi n del circuito hidr ul
209. mment ITALIEN FRANCAIS ANGLAIS ALLEMAND ESPAGNOL Buzzer Cette option permet de valider ou de d sactiver une signalisation sonore de la chaudi re Eclairage Cette option permet de modifier l intensit lumineuse de l cran r tro clair d un minimum de 0 un maximum de 100 Set Temp Ballon Puffer Il est possible de choisir la temp rature de CONSIGNE de l accumulateur d eau sanitaire sur le circuit chauffage ou sur les deux de 40 C mini a 80 C maxi Delta Ballon Puffer Cette fonction permet de fixer la diff rence de temp rature entre l extinction de la chaudi re et son rallumage suivant de 0 5 C mini a 20 C maxi en fonction des exigences du client et ou du type d installation Niveau granul s En mode ON il est possible de savoir si le r servoir a granul s est vide a l aide d un message ABSENCE GRANULES sur le tableau de la gestion d un r servoir suppl mentaire de recharge des granul s disponible sur demande En mode OFF l ventuel r servoir suppl mentaire est d sactiv et le tableau n affiche aucun message Valide ECS Cette fonction si l accessoire sanitaire pompe amp changeur vanne est configur permet de contr ler l eau chaude sanitaire partir du ballon ou de l changeur travers le signal provenant du thermostat ou du d bitm tre 4 6 4 Menu 04 tat de la chaudi re La s lection de cette option permet de visualiser l tat de la chaudi re dans
210. momento in cui si decide di non utilizzare definitivamente l apparecchio scollegare l alimentazione elettrica e scaricare completamente il pellet dal serbatoio Per provvedere allo smaltimento della caldaia necessario sigillarla all interno di un robusto imballo e contattare gli organismi locali preposti per queste operazioni in modo da procedere secondo le norme locali vigenti oppure riconsegnarla al rivenditore al momento dell acquisto di una nuova apparecchiatura similare Ai sensi dell art 13 del Decreto Legislativo n 151 del 25 luglio 2005 di attuazione della Direttiva 2002 96 CE del 23 Febbraio 2003 sui Rifiuti di Apparecchiature Elettriche ed Elettroniche relative alle misure e procedure finalizzate a prevenire la produzione di rifiuti di apparecchiature elettriche ed elettroniche denominate RAEE promuovendo il reimpiego il riciclaggio e altre forme di recupero in modo da ridurne la quantit da avviare allo smaltimento e migliorando l intervento dei soggetti che partecipano al ciclo di vita di tali prodotti Il simbolo del cassonetto barrato riportato sull etichetta dell apparecchiatura indica che il prodotto alla fine della propria vita utile deve essere raccolto separatamente dagli altri rifiuti urbani 1 10 Istruzioni per richiesta di intervento e ricambi Per richiedere qualsiasi intervento e o ricambio contattare il proprio rivenditore importatore di zona o il centro di assistenza autorizzato pi vicino esponendo in modo chi
211. n The controller does not detect AIRFLOW Secure Wherithe air ti wmeteris the amount of combustion air Reinstatement operations must METER disconrie fed and does not shut down the be carried out by a service FAILURE boiler it only excludes the air centre flow meter functions The pump starts in order to move Occurs when the water The boiler controller detects the the water inside the heating FROST RISK temperature falls below a certain water temperature below 6 C circuit value and displays a message Monitor the water temperature so that it does not fall below 0 Occurs when the boiler has exceeded 1800 hours of Cleaning extraordinary SERVICE operation since the previous Extraordinary maintenance maintenance and reinstatement DUE servicing notice operations must be carried out by an authorised service centre The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice The drawings measurements diagrams and any other configurations are given only by way of example 65 DOMUSFIRE C29 C35 C39 8 ENCLOSURES INFORMAZIONI MARCATURA CE CE MARKING INFORMATION ipologia Type COLA COLA TUV K8552012T1 K8552012T2 K8552012S3 EN 303 5 2012 Caldaia a pellet Heating Boiler Modello CE Combustibile Fuel Potenza termica introdotta Heating input Potenza termica utile Water heating output Rendime
212. n 7 Luftmassenmesser Legende 1 Volute f Saugzuggeblase 2 Warmedichtung 3 Motor Saugzuggeblase 4 Rauchabzugsrohr 5 Dichtung Legende 1 Dichtung Beh lter F rderer 2 Flansch f Getriebemotor 3 Getriebemotor 4 F rderschnecke 5 Dichtung f r Rutsche 6 Pelletrutsche 7 Dichtung Kammer F rderer 8 Pelletf rderer 125 DOMUSFIRE C29 C35 C39 COLA 6 4 Elektrische Bauteile Zeichenerkl rung 1 Bedienpanel Mod EVO 2 Sicherheitsthermostate Temperatur 3 ON OFF Schalter mit Schmelzsicherungen 4 Elektronische Platine 5 Netzkabel 6 Unterdruckwachter 7 Druckmessumformer Wasserkreis 7 Abgastemperaturf hler 8 Wassertemperaturf hler Heizkammer 9 Wassertemperaturfthler Boiler Puffer 10 Fullstandssensor Pelletbehalter 11 Serieller Anschluss 12 Druckmessumformer e o GER On e Zeichenerklarung 2 Membran Ausdehnungsgef 2 Anlagen Ablasshahn 12 3 Uberdruckventil 4 Vorlaufrohr mit Anschl ssen 1 5 Umwalzpumpe 6 R cklaufrohr mit Anschl ssen 1 7 Druckmessumformer 8 Anlagen Einf llhahn 72 9 Entl ftungsventil Anlage Kessel 126 DOMUSFIRE C29 C35 C39 7 FEHLERSUCHE 7 1 Verwaltung der Alarmmeldungen Ein Alarm wird durch ein akustisches Signal sofern aktiviert und eine Meldung am Bedienpanel angezeigt Bei Auftreten eines Alarms den
213. n Regelung aufgerufen werden k nnen In der nachstehenden Ubersicht ist die Men struktur und nur die f r den Benutzer verf gbaren Optionen dargestellt Men 01 Uhrenthermostat M 1 1 Uhrenthermostat M 1 1 01 Uhrenthermostat freigeben ON OFF freigeben einstellen M 1 2 01 Uhrenthermostat Tag M 1 2 02 Start 1 Tag M1 2 Program Tag M 1 2 03 Stop 1 Tag M 1 2 04 Start 2 Tag M 1 2 05 Stop 2 Tag M 1 3 01 Uhrenthermostat Woche ON OFF M 1 3 02 Start Prog 1 M 1 3 03 Stop Prog 1 M 1 3 04 Montag Prog 1 M 1 3 05 Dienstag Prog 1 M 1 3 06 Mittwoch Prog 1 M 1 3 07 Donnerstag Prog 1 M 1 3 08 Freitag Prog 1 M 1 3 09 Samstag Prog 1 M 1 3 10 Sonntag Prog 1 M 1 3 11 Start Prog 2 M 1 3 12 Stop Prog 2 M 1 3 13 Montag Prog 2 M 1 3 14 Dienstag Prog 2 M 1 3 15 Mittwoch Prog 2 M 1 3 16 Donnerstag Prog 2 M 1 3 17 Freitag Prog 2 M 1 3 18 Samstag Prog 2 M1 3 Program Woche M 1 3 19 Sonntag Prog 2 M 1 3 20 Start Prog 3 M 1 3 21 Stop Prog 3 M 1 3 22 Montag Prog 3 M 1 3 23 Dienstag Prog 3 M 1 3 24 Mittwoch Prog 3 M 1 3 25 Donnerstag Prog 3 M 1 3 26 Freitag Prog 3 M 1 3 27 Samstag Prog 3 M 1 3 28 Sonntag Prog 3 M 1 3 29 Start Prog 4 M 1 3 30 Stop Prog 4 M 1 3 31 Montag Prog 4 M 1 3 32 Dienstag Prog 4 M 1 3 33 Mittwoch Prog 4 M 1 3 34 Donnerstag Prog 4
214. n de humos Si por cualquier motivo el ventilador de extracci n de humos se detiene el control electr nico bloquea instant neamente la entrada de pellets y visualiza el mensaje AL 4 FALLO ASPIR 144 DOMUSFIRE C29 C35 C39 COLA 4 USO DE LA CALDERA 4 1 Introducci n La caldera de pellets a na el calor generado por la combusti n de la madera y la comodidad del control autom tico de la temperatura del agua con posibilidad de programar el encendido y apagado para toda la semana y de conectar un termostato o cronotermostato para controlar dichas funciones a distancia Para un uso seguro se aconseja tener en cuenta las siguientes indicaciones la primera puesta en marcha se puede sentir mal olor Airee bien el local especialmente en el primer encendido Cargue el dep sito exclusivamente con pellets de buena calidad Durante la carga evite que el saco entre en contacto con las superficies calientes de la caldera introduzca en el dep sito ning n combustible que no sea el pellet indicado en este manual No utilice el equipo para incinerar residuos Lacaldera debe funcionar siempre con la puerta de la c mara de combusti n cerrada Controle peri dicamente las juntas de la puerta de la c mara de combusti n y del cenicero para prevenir filtraciones de aire Para garantizar un rendimiento t rmico adecuado y un funcionamiento correcto limpie el brasero cada vez que cargue pellets Al primer encendi
215. n kann ernsthafte Sach und Personensch den zur Folge haben Angaben die besondere Aufmerksamkeit erfordern sind fett gedruckt 1 3 Sicherheitsvorschriften Vor der Installation Benutzung oder Wartung des Kessels die Bedienungs und Wartungsanleitung lesen Installation Stromanschluss Abnahme und Wartung sind von einem qualifizierten und oder autorisierten Techniker durchzuf hren Den Kessel Uber ein inspizierbares Endst ck an ein vorschriftsmaBiges Schornsteinrohr anschlieBen Der Anschluss mehrerer Ger te ist nur zul ssig wenn er von den rtlichen Bestimmungen vorgesehen ist und von der Kontrollbeh rde des Schornsteins genehmigt wurde Kessel ber ein Rohr bzw eine Au enluftzuf hrung an die Ansaugung anschlie en Den Kessel an eine vorschriftsmaBige Steckdose mit Spannungswerten 230 V 50 Hz anschlieBen Die elektrische Anlage und die Steckdosen m ssen f r die maximale Stromaufnahme des Ger ts geeignet sein die auf dem Etikett und im vorliegenden Handbuch angegeben ist Der netzstecker muss leicht zug nglich sein Das Ger t an die Heizungsanlage anschlie en es darf auf keinen Fall ohne Wasseranschluss noch ohne Wasserf llung in Heizkammer und Anlage verwendet werden Die Benutzung dieses Ger t durch Personen einschlie lich Kinder mit eingeschr nkten physischen sensorischen oder geistigen F higkeiten oder mangelnder Erfahrung und oder Wissen ist verboten es sei denn
216. n un lugar seco y protegido Para garantizar un funcionamiento regular y eficaz no coloque pellets ni otros combustibles A manualmente en el brasero Con el tiempo en el dep sito de pellets se acumula polvo que puede dificultar la alimentaci n del producto por lo cual se aconseja quitar el polvo antes de cargar los pellets No cargue en el dep sito combustibles no aprobados No introduzca objetos extra os en el dep sito como recipientes cajas bolsas o metales El uso de pellet de baja calidad y no aprobado compromete el funcionamiento del equipo y puede da arlo con anulaci n de la garant a y exenci n de responsabilidad del fabricante 1 6 Accesorios suministrados El suministro incluye Cable de alimentaci n el ctrica Manual de instalaci n uso y mantenimiento Manija para abrir y cerrar la puerta 135 DOMUSFIRE C29 C35 C39 COLA 1 7 Normas de referencia Norma UNI 10683 2005 Requisitos de instalaci n de generadores de calor alimentados con le a otros biocombustibles s lidos Norma EN 303 5 2012 Terminolog a requisitos ensayos y marcado relativos a calderas para combustibles s lidos con alimentaci n manual o autom tica Norma UNI 10412 2 2009 Requisitos espec ficos para instalaciones con aparatos de calefacci n de tipo dom stico abastecidos por calderas de combustible s lido Parte 2 Norma EN 60335 1 Seguridad de aparatos electrodom sticos y similares Parte 1 Norma CEI EN
217. n werden verursacht z B durch zum Trocknen aufgehangte W sche W hrend des Betriebs ist der Umgang mit leicht entflammbaren oder explosiven Stoffen in der Nahe des Kessels untersagt 100 DOMUSFIRE C29 C35 C39 COLA Die Sicherheits oder Regelvorrichtungen d rfen nicht ohne vorherige Genehmigung des Herstellers ver ndert werden Jegliche nderung und oder jegliches nicht zul ssige Auswechseln mit nicht Original Ersatzteilen des Kessels ist eine Gefahr f r die Benutzer und enthebt den Hersteller von jeder Haftpflicht und strafrechtlichen Verantwortungen Ausschlie lich die vom Hersteller empfohlenen Ersatzteile benutzen Bei Auftreten von Betriebsst rungen darf der Kessel erst wieder eingeschaltet werden nachdem die Ursache f r das Problem beseitigt wurde Auf keinen Fall die Sicherheitssysteme deaktivieren Im Brandfall die Heizungsanlage ausschalten die Spannungszufuhr trennen geeignete L schma nahmen ergreifen und oder Feuerwehr rufen Der Brenntopf bei jedem Anz nden und oder Nachladen von Pellets reinigen Beim Einschalten und oder beim normalen Betrieb die Bildung von Rauch und unverbrannten Stoffen vermeiden die berm ige Ansammlung von unverbrannten Pellets im Brenntopf muss von Hand vor dem erneuten Einschalten beseitigt werden Mindestens einmal j hrlich die regelm ige Wartung des Kessels durchf hren lassen Den Eingriff rechtzeitig mit dem Personal der autorisierten Kundendienstelle progr
218. n y hacer los ajustes disponibles seg n el nivel de acceso En la tabla siguiente se detallan los mandos y los mensajes que aparecen durante la programaci n y el ajuste de los par metros de funcionamiento tecla descripci n modo acci n indic superior indic inferior l mites Aumenta la consigna de los AJUSTE aire 7 40 C termostatos de AGUA y de Ajuste H2O aire Temperatura d 1 Aumentar TEMPERATURA AMBIENTE agua 30 C 80 C temperatura A Aumenta el valor del par metro Par metro S _ PROGRAMACION testando lessen Valor parametro TRABAJO Visualiza las temperaturas Temperatura humos Temperatura agua Disminuye la consigna de los AJUSTE E aire 7 C 40 C TEMPERATURA termostatos de AGUA y de Ajuste H2O aire Temperatura agua 30 C 80 C o AMBIENTE 2 en PROGRAMACION Disminuye el valor del parametro Parametro Vania seleccionado seleccionado Muestra el estado operativo de la Presi n en el circuito Velocidad ventilador O caldera de agua humos Con presiones sucesivas da acceso 3 Set Men al ajuste de temperatura y al men Ajuste par metro Temperatura valor de par metros de usuario y t cnico Presionada durante 2 segundos TRABAJO enciende o apaga la caldera seg n MEUM que est apagada o encendida i ON OFF Desbloquea la caldera y la deja 2 Desbloqueo SES apagada Permite salir del men de PROGRAMACI N _ programaci n en cualquier punto Los ca
219. nHm at reference 10 02 Ea O _ _ TE Emission bei 10 O mission NOx at reference 1096 o 2 _ mr idis Kee 2 IStaubemission bei 10 245 95 mission dust at reference 10 gt iiis Emission bei 139602 era 4 9 13 78 4 8 13 78 4 9 13 78 mission CnHm at reference 13 O ls eer ee 106 8 84 6 107 84 6 947 846 mission NOx at reference 13 O b DX diio IStaubemission bei 13 mission dust at reference 1396 o 2 T E iod s N Insgesamt Staubemission PPBT bei 13 O Total emission dust PPBT at ref 13 19 66 12 69 19 22 12 69 19 86 12 69 jaximale wassertemperatur set C et max temp jax Betriebsdruck 3 lax working pressure assungsvermogen Warmekammer leating chambre capacity Behalterinhait Pellet stove capacity lasse von Kessel rif EN303 5 2012 5 Boiler class rif EN303 5 2012 Druckabfall auf der Wasserseite AT 10K 386 9 Water resistance AT 10K Druckabfall auf der Wasserseite AT 20K 96 73 Water resistance T 20K 134 3 62 6 148 6 62 6 outlet temperature Abgasmassenstrom 163 54 lue gas fiow i inderstzug min max 10 14 0 10 0 14 Draught 0 Rauchabzugsrohr ume outlet pipe lektrische Versorgung Jectrical power EM 230V 50Hz 6A Stromaufnahme Rated input power Zundung 476 Stand by 4 P nen 160 P rid 153 1300 700
220. nda est averiada SS E i restablecimiento deben ser SONDA humos La sonda esta desconectada de T efectuadas por un centro de HUMOS Se activa el procedimiento la tarjeta asistencia autorizado de apagado La sonda de humos AL 3 detecta una temperatura de Carga excesiva de pellets ee los humos superior a Intercambio t rmico reducido SE ALTA TMP 280 fainstalaci n restablecimiento debe ser HUMOS Se activa el procedimiento efectuada tro de d asistencia autorizado le apagado un al dei El ventilador de los humos esta AL 4 ventilador de aspiraci n de d ND FALLO los humos El sensor de contro de restablecimiento deben ser Ca activa al procedimiento velocidad est averiado efectuadas por un centro de ASPIR de apagado No llega alimentaci n el ctrica asistencia autorizado al ventilador de humos Verificar la presencia de El dep sito de pellets esta pellets en el dep sito AL5 Al dar encendido no se vacio Verificar el procedimiento de FALLO produce llama La resistencia el ctrica esta encendido Se activa el procedimiento averiada sucia mal ubicada Toda otra operaci n de ENCEND de apagado Calibraci n de la carga de restablecimiento debe ser pellets incorrecta efectuada por un centro de asistencia autorizado El dep sito de pellets est a as SR vacio BES No entran pellets al El motorreductor de carga de R
221. ndo golpes Es indispensable comprobar que el suelo pueda resistir el peso de la caldera si no es as consulte a un t cnico especializado Una vez retirado el embalaje tenga mucho cuidado de no da ar las partes mec nicas y el ctricas con golpes o salpicaduras de agua El lugar de instalaci n debe estar suficientemente ventilado para permitir la evacuaci n de una eventual p rdida de humos de combusti n El equipo est realizado para funcionar en ambientes t cnicos con temperatura no inferior a O C Est dotado de funci n antihielo que activa la bomba de calefacci n cuando la temperatura del agua de la instalaci n se hace inferior a 6 a fin de proteger la c mara t rmica y el circuito de calefacci n agua sanitaria La funci n antihielo est operativa solo si la caldera est conectada a la alimentaci n el ctrica La caldera debe estar suficientemente aislada de materiales inflamables mediante c maras de aire o material aislante Adem s los suelos techos o cubiertas inflamables o sensibles al calor deben protegerse con paneles aislantes Controle que a los lados y detr s de la caldera quede espacio suficiente para realizar el mantenimiento y la limpieza del equipo de los tubos de humos y de la chimenea Compruebe tambi n que el dep sito de pellets sea f cilmente accesible para hacer la carga del combustible En la tabla siguiente se indican las distancias m nimas de mantenimiento y seguridad DEP SIT
222. nect the boiler to an approved 230 V 50 Hz electrical socket Make sure the electrical system and the sockets are suitable for the maximum absorption of the unit specified on the label and in this manual The power plug must be easily accessible Connect the unit to the heating system under no circumstances can it be used without the hydraulic connection and without water in the heating chamber and system This unit must not be used by people including children with limited physical sensory or mental abilities or without experience and knowledge of it unless instructed in its use by those responsible for their safety Children must be supervised to make sure they do not play with the unit and in the place of installation A Arrange the power cable and any cables of external sensors so that they do not touch hot parts of the unit Do not operate the unit with the fire door and or ash box door open Do not close or reduce the size of the combustion air inlet and fume exhaust openings The boiler must not be used as an incinerator but exclusively to heat the water of the heating and or DHW system only using wood pellets having the characteristics described in this manual as fuel Do not use flammable liquids or substances to light the boiler The boiler must not be used as a waste incinerator Do not handle easily flammable or explosive substances near the boiler while it is in operation Avoid direct contact with parts of t
223. nel lateral para acceder al control electr nico Gui ndose por el esquema el ctrico conecte los dos cables del termostato a los respectivos bornes TERM de la tarjeta Restablezca el estado normal de la caldera y compruebe el funcionamiento Estos ajustes no modifican la programaci n realizada con el men La conexi n se indica con el encendido del s mbolo en la barra de estado de la pantalla Cuando se alcanza la temperatura programada el termostato apaga la caldera y en pantalla aparece la indicaci n de STAND BY si esta funci n est habilitada 4 11 Per odo de inactividad fin de temporada Si no utilizar la caldera por un tiempo prolongado o al final de la temporada proceda del siguiente modo Descargue todo el pellet del dep sito Desconecte la alimentaci n el ctrica Limpie esmeradamente y si es necesario haga sustituir las partes da adas por un t cnico autorizado Cubra la caldera para protegerla del polvo Gu rdela en un lugar seco seguro y protegido de los agentes atmosf ricos 153 DOMUSFIRE C29 C35 C39 COLA 5 LIMPIEZA DE LA CALDERA La limpieza de la caldera es importante para evitar la combusti n incorrecta el dep sito de cenizas e inquemados en el brasero y la disminuci n de la eficiencia t rmica La caldera debe funcionar siempre con las puertas de la c mara y del cenicero cerradas Las juntas de las puertas deben controlarse peri dicamente para evitar filtraciones de aire
224. nnection it is necessary to access the technical menu of the controller and select the type of circuit every specific DHW function set DHW EXCHANGER ACCUMULATOR PUFFER or DHW STORAGE TANK appears on the display at the moment of heating DHW switchover with one of the messages given below and remains until the end of the DHW request by the thermostat or flow switch 1436 436 436 eS She 56 pis SANI EArY REER bOI LER EXE HAnG bU LER SANI LAY 2 9 4 Boiler hydraulic diagrams Hydraulic diagram Pellet boiler with pump Pellet boiler Thermostat T gt 85 C A DELIVERY Heating male 1 B RETURN Heating male 1 C DHW DELIVERY male 3 4 Pellet heating chamber D DHW RETURN male 3 4 E Water supply F1 2 F Water overpressure discharge F1 2 r H il M 3 4 TIS 1 E F 1 2 gt F Flow switch 8 Pressure gauge pressure sensor 8 Plate heat exchanger for DHW Circulating pump 0 Circuit balancing valves 5 Membrane expansion tank a Automatic thermostatic valve Shutoff valve cock Safety sensor T gt 85 C Non return valve Water temperature sensor Circuit heating chamber air vent Circuit pressure sensor Pressure relief valve P max 3 bar pea Valves to be included in the system during Pressure relief valve P max 6 bar installation not supplied with the unit 48 DOMUSFIRE C29 C35 C39 COLA Hydraulic diagram of pel
225. nto termico Efficiency DOMUSFIRE c29 DOMUSFIRE c35 DOMUSFIRE c39 Pellet di legno Wood pellet UNI EN14961 2_classe A1 29 0 6 4 27 4 5 78 94 45 90 14 34 4 6 4 38 3 6 4 324 5 78 94 18 90 14 34 9 5 78 91 32 90 14 Consumo orario Fuel consumption Emissione CO al 10 O2 Emission CO at reference 10 O2 Emissione CnHm al 10 Oz Emission CnHm at reference 10 O Emissione NOx al 10 Emission NOx at reference 10 O Emissione polveri al 10 O2 Emission dust at reference 10 O Emissione CO al 13 02 Emission CO at reference 13 Emissione CnHm al 13 Emission CnHm at reference 13 gt Emissione NOx al 13 Emission NOx at reference 13 O gt Emissione polveri al 13 Emission dust at reference 13 O gt Emissione particolato totale PPBT al 13 Total dust emission PPBT at ref 13 O2 emperatura max acqua impostabile Set max temp Pressione max acqua di esercizio Max working pressure Capacit acqua caldaia Heating chambre capacity Capacit serbatoio pellet Pellet stove capacity Classe della caldaia rif EN303 5 2012 Boiler class rif EN303 5 2012 Perdite di carico lato acqua AT 10K Water resistance AT 10K Perdite di carico lato acqua AT 20K Water resistance AT 20K emperatura uscita fumi Fume outlet temperature Portata dei fumi Flue gas flow Tiraggio canna fumaria min max Draught min max Diametro tubo sca
226. ntrolle von Brenntopf und Turbulatoren Vor dem Einschalten des Kessels unbedingt kontrollieren ob sich der Brenntopf in korrekter Position befindet d h in den hierf r vorgesehenen Aufnahmen eingerastet ist Au erdem kontrollieren ob sich der Turbulatorr ttler in Ruhestellung d h unten befindet Eine falsche Position des Brenntopfes und oder der Turbulatoren hat die Bildung von Staub und unverbrannten Stoffen zur Folge A Jedes Mal wenn das Ger t eingeschaltet wird muss die korrekte Position des Brenntopfes und des Turbulatorenr ttlers kontrolliert werden 2 6 Elektrischer Anschluss Das eine Ende des Netzkabels an den Stecker an der Kesselr ckseite das andere Ende an eine Wandsteckdose anschlieBen Die vom Stromnetz gelieferte Spannung muss den Angaben auf dem Typenschild des Kessels und den im vorliegenden Handbuch enthaltenen technischen Daten entsprechen Wenn der Kessel nicht benutzt wird den Stromanschluss trennen einer Erdung und einem Fehlerstromschutzschalter ausgestattet sein Die elektrische Anlage muss vorschriftsm ig ausgef hrt und gem den geltenden Bestimmungen mit A Das Netzkabel darf auf keinen Fall mit dem Abzugsrohr des Kessels in Ber hrung kommen 108 DOMUSFIRE C29 C35 C39 COLA 2 7 Elektroschaltplan Yass SINN3SSVIALA CYI 1906006 E in t 9912 SINO 9 ol 7 Lo es O C
227. o a un centro especializado en el tratamiento de este tipo de equipos o entr guela al vendedor si adquiere una nueva de caracter sticas similares Con arreglo al art 13 del Decreto Legislativo italiano n 151 del 25 de julio de 2005 de actuaci n de la Directiva 2002 96 CE del 23 de febrero de 2003 sobre Residuos de Aparatos El ctricos y Electr nicos RAEE que promueve la reutilizaci n el reciclaje y otras formas de recuperaci n de aparatos el ctricos y electr nicos a fin de disminuir la generaci n de residuos y mejorar el comportamiento medioambiental de todos los agentes que intervienen en el ciclo de vida de tales productos El s mbolo del contenedor tachado que aparece en la etiqueta del equipo indica que este al final de su vida til no debe desecharse junto con otros residuos 1 10 Pedido de reparaciones y recambios Para solicitar reparaciones o recambios contacte con el vendedor del equipo el importador de zona o el centro de asistencia autorizado m s cercano indicando de modo claro los siguientes datos modelo de caldera n mero de serie fecha de compra lista de recambios e informaci n sobre las anomal as observadas Antes de realizar cualquier operaci n se debe comprobar que la caldera est desconectada de la electricidad y fr a Exija el uso de recambios originales N Los componentes deben ser reparados por personal autorizado 136 DOMUSFIRE C29 C35 C39 COLA 2 TRANSPORTE E INSTALACION 2 1 Con
228. o essere condotte SERVICE intervento di manutenzione emana da un centro di assistenza autorizzato La ditta si riserva di apportare in qualsiasi momento senza preavviso alcuno eventuali modifiche tecniche od estetiche ai prodotti disegni le misure gli schemi ed ogni altra configurazione sono qui riportati solo a scopo esemplificativo 35 DOMUSFIRE C29 C35 C39 COLA 8 ALLEGATI INFORMAZIONI MARCATURA CE CE MARKING INFORMATION TUV K8552012T1 K8552012T2 K8552012S3 13 EN 303 5 2012 Tipologia Modello DOMUSFIRE DOMUSFIRE DOMUSFIRE Model c29 c35 c39 ei Pellet di legno Wood pellet UNI EN14961 2_classe A1 Pot t ica utile fater heating outp al 94 45 90 14 94 18 90 14 91 32 90 14 Effi ficiency consumption natal 0 005 0 040 0 007 0 040 0 009 0 040 Emission CO at reference 10 O2 Emissione CnHm al 10 O 3 4 Emission at reference 10 2 w DE 146 7 116 4 147 1 116 4 130 2 116 4 Emission NOx at reference 10 O mg m i J i i Emissione polveri al 10 O 3 Emissi CO al 13 02 D ri 14 Emissione CnHm al 13 O 2 3 E _ 9 Emission CnHm at reference 13 gt o gem 5 dici Emissione NOx al 13 O 3 ES 94 7 Emissione polveri al 13 O 3 Emission dust at reference 13 O gt amis MESNA eo Emissione particolato totale PPBT al 13 O 3 19 66 12 6 19 22 12 69 19 8
229. o remove any dust before reloading pellets Do not load non conforming fuels in the hopper Do not put foreign bodies such as containers boxes bags metals etc in the hopper The use of poor quality or non conforming pellets will damage and compromise the unit s operation invalidating the warranty and relieving the manufacturer of any liability 1 6 Accessories supplied The supply includes Power cable Installation use and maintenance manual Opening closing key 41 DOMUSFIRE C29 C35 C39 COLA 1 7 Reference standards Standard UNI 10683 2012 Installation requirements for heat generators burning wood or other solid biofuels Standard UNI EN303 5 2012 Terminology requirements tests and marking relevant to Boilers for solid fuels with manual and automatic feed Standard UNI 10412 2 2009 Safety requirements for domestic type heating units using heat generators fed with solid fuel part 2 Standard CEI EN 60335 1 Safety of electrical appliances for domestic and similar use part 1 Standard EN 60335 2 102 Safety of electrical appliances for domestic and similar use part 2 Standard CEI EN 55014 1 Electromagnetic resistance Requirements for electrical appliances electric tools and similar electrical equipment Part 1 Interference Standard CEI EN 55014 2 Electromagnetic resistance Requirements for electrical appliances electric tools and similar electrical equipment Part 2 Immunity Pro
230. odifying the water temperature setting 4 4 2 Restart from STANDBY 4 4 3 Cleaning the brazier 4 4 4 DHW with rapid heat exchanger 4 4 5 DHW with storage tank 4 4 6 System with puffer heat accumulator 4 5 Shutting down 37 COLA 4 7 Menu 4 6 1 menu 01 chrono setting 4 6 2 menu 02 user adjustment 4 6 3 menu 03 user setting 4 6 4 menu 04 boiler status 4 6 5 menu 05 installer adjustments 4 7 Thermostat external chronothermostat 4 8 ldle period end of season 5 BOILER CLEANING 5 1 Cleaning the brazier brazier holder 5 2 Cleaning the ash container 5 3 Cleaning the fume extractor and combustion hambre 5 4 Cleaning the air flow meter 5 5 Cleaning the flue flue connection 5 6 Cleaning the exchanger with turbulator shaker device 6 MAINTENANCE 6 1 Introduction 6 2 Removing the boiler cladding 6 3 Boiler internal parts 6 4 Electrical components 6 5 Standard hydraulic components 7 TROUBLESHOOTING 7 1 Alarm management 8 ENCLOSURES 8 1 CE marking informations DOMUSFIRE C29 C35 C39 COLA 1 GENERAL INFORMATION 1 1 Introduction Dear Customer First of all we wish to thank you for the trust placed in us by purchasing one of our products Please read and carefully follow the advice given in this installation use and maintenance manual in order make best use of the product 1 2 Using the manual The Manufacturer reserves the right to make technical or aesthetic changes to t
231. og 1 M 1 3 11 Start Prog 2 M 1 3 12 Stop Prog 2 M 1 3 13 Lunes Prog 2 M 1 3 14 Martes Prog 2 M 1 3 15 Mi rcoles Prog 2 M 1 3 16 Jueves Prog 2 M 1 3 17 Viernes Prog 2 Program M 1 3 18 S bado prog 2 M1 3 1 3 19 Domingo Prog 2 M 1 3 20 Start Prog 3 M 1 3 21 Stop Prog 3 M 1 3 22 Lunes Prog 3 M 1 3 23 Martes Prog 3 M 1 3 24 Mi rcoles Prog 3 M 1 3 25 Jueves Prog 3 M 1 3 26 Viernes Prog 3 M 1 3 27 S bado prog 3 M 1 3 28 Domingo Prog 3 M 1 3 29 Start Prog 4 M 1 3 30 Stop Prog 4 M 1 3 31 Lunes Prog 4 M 1 3 32 Martes Prog 4 M 1 3 33 Mi rcoles Prog 4 M 1 3 34 Jueves Prog 4 M 1 3 35 Viernes Prog 4 M 1 3 36 S bado prog 4 M 1 3 37 Domingo Prog 4 M 4 2 01 Crono fin semana ON OFF Program fin M 4 2 02 Start 1 fin semana M1 4 STE M 4 2 03 Stop 1 fin semana M 4 2 04 Start 2 fin semana M 4 2 05 Stop 2 fin semana Menu 04 Ber Estado caldera menu para el t cnico Men 05 Ajustes men para el t cnico instalador 150 DOMUSFIRE C29 C35 C39 4 6 1 Menu 01 Ajustes crono Permite habilitar y deshabilitar todas las funciones del cronotermostato Con la selecci n ON se activa la funci n en pantalla aparece el s mbolo D Cuando se realiza la programaci n diaria G semanal S o de fin de semana y W en la parte superior derecha de la pantalla aparece el s mbolo C d C 5 C Para ajustar los horarios utilice las seis teclas como se indica en la tabla del E RAbAUD j aparta
232. ol panel comprises a backlit LCD on off button P4 SET MENU button P3 four menu buttons P1 P2 P5 P6 and seven boiler operation status LEDs Status indicators Backlit LCD Display indications 12 Setting buttons Setting vu and selection buttons l selection button IR receiver The panel enables boiler lighting and shutdown adjustment during operation and the setting of management and maintenance programs The display shows all the information on boiler operation status To access the menus proceed as follows press the SET button P3 press the buttons P5 P6 to scroll the various menus press one of the increase decrease buttons P1 P2 to set the required parameter press the SET button P3 to confirm the parameter value On accessing the menu it is possible to obtain the various types of displays and make settings depending on the access level Given below is the table of controls and respective messages displayed during programming or setting operation parameters 51 DOMUSFIRE C29 C35 C39 COLA button description mode action top display bottom display limits air 7 C 40 Increase the WATER AND AMBIENT C water SET TEMPERATURE thermostat temperature value SET H2O air Temperature 30 C 80 1 Increase temperature Selected PROGRAMMING Increase the selected parameter
233. olatore 6 Tubo di ritorno con attacco da 1 7 Trasduttore di pressione 8 Attacco di carico impianto da 1 2 9 Valvola di sfiato aria impianto caldaia DOMUSFIRE C29 C35 C39 7 RICERCA GUASTI 7 1 Gestione degli allarmi La presenza di un allarme si identifica con l emissione di un segnale acustico se attivato e con un messaggio presente sul pannello di controllo In caso di allarme spegnere la caldaia risolvere la causa che lo ha provocato e riavviare la caldaia secondo la normale procedura illustrata nel presente manuale Ogni condizione di allarme causa l immediato spegnimento della caldaia Sotto sono elencati gli allarmi che possono comparire sul pannello di controllo con cause e rimedi CCLA ALLARMI MESSAGGI Segnalazione Anomalia Cause possibili Rimedi Portare la caldaia in OFF premendo il pulsante P4 e Manca l alimentazione ripetere la procedura di AL 1 e BLACK OUT La caldaia non si avvia elettrica durante la fase di accensione accensione Altre operazioni di ripristino devono essere condotte da un centro di assistenza Avviene nel caso di guasto AL 2 della sonda di rilevamento La sonda guasta Le operazioni di ripristino SONDA della temperatura dei fumi La sonda scollegata dalla devono essere condotto da un FUMI Viene attivata la procedura di scheda centro di assistenza spegnimento nn een Eccessivo carico pellet Regolare l af
234. onctionnement normal doivent lus de 60 5 commande du motor ducteur est tre effectu es par un centre TRIAC COC sys mE est arr t d faillant contacts coll s d assistance Se d clenche en cas de panne de la sonde 3 TE D autres op rations de AL c de d tection de la T eau Be n SS ec dela tablissement du fonctionnement SONDE EAU en affichant T H20 0 C normal doivent tre effectu es La proc dure d extinction par un centre d assistance est activ e Cette alarme se d clenche cere elaine se uoelencle AL d la temp rature de lealia lorsque la sonde de temp rature V rifier la cause de l anomalie et HOT d Ges les nee r d finies mont e dans la chambre de r tablir la temp rature la valeur EAU A ene est ir i combustion rel ve une valeur normale sup rieure 92 C Cette alarme se d clenche Tentative de d blocage en phase de l alarme ne ATTENTE rallumant la chaudi re d extinction avec la chaudi re aus i Se A EE sera possible qu une fois la REFROID imm diatement apr s l avoir chaude en phase de chaudi re Steine teinte refroidissement L lectronique de commande PANNE A rel ve pas la quantit d air Les op rations de r tablissement DU i comburant mais n teint pas la du fonctionnement normal 2 a chaudi re elle exclut doivent tre effectu es par un DEBITMETRE uniquement les fonctions du centre
235. ono riassunti gli interventi di controllo e o manutenzione utili per il corretto utilizzo e funzionamento della caldaia Parti Periodo Lgiomo 2 3 giorni Less 2 3 mesi m Tipologia della pulizia ordinaria Brana pre pulizia ordinaria a ae Braciere Vano cenere cassetto n Fascio tubiero termocamera Collettore estrattore fumi Guarnizione porta fuoco cenere n Canna raccordo fumario 5 1 Pulizia braciere portabraciere Togliere il braciere ed asportare i residui di cenere che si sono depositati nella camera di combustione e nel porta braciere A tale scopo pu essere utilizzato un idoneo aspiratore Questa operazione dovr essere eseguita quotidianamente soprattutto in presenza di accumulo di materiale incombusto per assicurare una perfetta condizione di combustione in quanto i fori del braciere permettono il passaggio dell aria di combustione Verificare inoltre che i fori dei tubi laterali del porta braciere per la distribuzione dell aria secondaria siano liberi da residui di combustione e da eventuali accumuli di cenere Pulire quando serve il vetrino dello spioncino porta fuoco per garantire il controllo visivo della presenza fiamma all interno della camera di combustione Il braciere deve appoggiare sul porta braciere e precisamente su tutta la fascia anulare senza presentare luci di passaggio aria Braciere sporco Braciere pulito Porta Braciere pulito 5 2 Pul
236. ontroller instantly stops the pellet supply displaying the message AL4 FAN FAIL 50 DOMUSFIRE C29 C35 C39 COLA 4 BOILER USE 4 1 Introduction The pellet boiler has the advantage of combining the heat generated by the combustion of wood with the convenience of automatic water temperature management and the possibility of weekly programming of switching on off as well as the connection of a thermostat and or chronothermostat and start stop remote control For safe and reliable use when lighting and using the unit the first time unpleasant odours may be created therefore air the room thoroughly hopper must only be filled with good quality pellets make sure the bag does not come into contact with the hot surfaces of the boiler do not put any fuel other than the prescribed pellets in the hopper the unit must not be used as a waste incinerator the boiler must only operate with the fire door always closed the fire and ash door seals must be checked periodically to prevent air from entering to ensure thermal efficiency and correct operation it is necessary to clean the brazier every time pellets are loaded when lighting the boiler for the first time allow it to heat up gradually by setting low operating temperatures see the section on temperature setting during lighting operation and shutdown the boiler may creak a little due to the heat expansion 4 2 Description of control panel The contr
237. or forcing can damage the fume extractor making it noisy during operation therefore it is advisable to have this operation carried out by qualified personnel 5 4 Cleaning the air flow meter The air flow meter it measures the flow of combustion air installed inside the inlet pipe requires periodical internal cleaning every 3 4 months using suitable equipment blowing compressed air or suitable brushes 5 5 Cleaning the flue flue connection The flue connection must be cleaned at least once a year or whenever necessary Cleaning requires the suction and removal of the residuals in all the vertical and horizontal sections as well as the bends from the unit to the flue It is advisable to also clean the flue every year to ensure correct and safe evacuation of fumes 5 6 Cleaning the exchanger with turbulator shaker device The fume ducts inside the heating chamber must be cleaned at least once every 2 3 days by operating the two knobs repeatedly with an upward and downward movement Do this with the boiler off and cold At the end of the operation make sure the turbulators are in the rest position on the lowest level RH LH control knobs of the turbulator shaker device in boiler operation low position 60 DOMUSFIRE C29 C35 C39 COLA 6 MAINTENANCE 6 1 Introduction Operations on the internal parts of the boiler must be carried out by qualified personnel Contact the nearest authorised service centre A Mak
238. ore del display a destra appare rispettivamente il segmento led appropriato Per quanto riguarda le selezioni e l inserimento degli orari neces sario agire sui sei pulsanti attenenendosi alla tabella del paragrafo 4 2 Entrando nel sottomenu PROGRAM GIORNO possibile abilitare disabilitare e impostare le funzioni del cronotermostato giornaliero E possibile settare due fasi di funzionamento delimitate dagli orari impostati secondo la tabella seguente dove l impostazione OFF indica all orologio di ignorare il comando START START 2 ora di attivazione ora OFF STOP 2 ora di disattivazione ora OFF Entrando nel sottomenu PROGRAM SETTIM possibile abilitare disabilitare e impostare le funzioni del cronotermostato settimanale Il programmatore settimanale dispone di 4 programmi indipendenti il cui effetto finale composto dalla combinazione delle 4 programmazioni Il programmatore settimanale pu essere attivato o disattivato inoltre impostando OFF nel campo orari l orologio ignora i comando corrispondente far sovrapporre le ore di attivazione e o disattivazione i Effettuare la programmazione con attenzione evitando di nello stesso giorno in differenti programmi Entrando nel sottomenu PROGRAM WEEK END possibile abilitare disabilitare e impostare le funzioni del cronotermostato nel week end fine settimana sabato domenica Attivare la programmazione WEEK END solament
239. otection contre les surtensions 3 7 S curit contre la surpression du circuit hydraulique 3 8 Dysfonctionnement du ventilateur d extraction des fum es 4 UTILISATION DE LA CHAUDIERE 4 1 Introduction 4 2 Description du tableau de commande 4 3 Allumage 4 3 1 Contr le avant l allumage 4 3 2 Mise en marche 4 4 Fonctionnement 4 4 1 Modification du pr r glage de la temp rature de l eau 4 4 2 Remise en marche a partir du mode VEILLE STAND BY 4 4 3 Nettoyage du brasier 4 4 4 Eau chaude sanitaire avec changeur rapide 4 4 5 Eau chaude sanitaire avec ballon d accumulation 4 4 6 Installation avec puffer accumulateur de chaleur 4 5 Extinction 67 COLA 4 8 Menus 4 6 1 menu 01 valeurs du chrono 4 6 2 menu 02 r glages de l utilisateur 4 6 3 menu 03 valeurs de l utilisateur 4 6 4 menu 04 tat de la chaudi re 4 6 5 menu 05 r glages de l installateur 4 7 Thermostat chronothermostat externe 4 8 P riode d inactivit fin de saison 5 NETTOYAGE DE LA CHAUDI RE 5 1 Nettoyage du brasier porte brasier 5 2 Nettoyage du cendrier 5 3 Nettoyage de l extracteur de fum e et de la chambre de combustion 5 4 Nettoyage du d bitm tre 5 5 Nettoyage du conduit de raccordement conduit de fum e 5 6 Nettoyage des changeurs avec le dispositif de secouage des turbulateurs 6 ENTRETIEN 6 1 Introduction 6 2 D montage de l habillage de la chaudi re 6 3 Composants internes de la chaudi re 6 4 Composant
240. overe le assi o parti in legno dell imballo della caldaia utilizzare adeguate attrezzature Lo smaltimento o il riciclaggio dell imballo a cura dell utente finale rispettando le norme locali vigenti in materia di rifiuti ed evitando che sia alla portata di bambini o persone disabili 2 2 Luogo d installazione posizionamento e sicurezza antincendio Dopo aver predisposto l allacciamento idraulico ed elettrico da parte di un tecnico qualificato aprire l imballo rimuovere la caldaia dal bancale e posizionarla nel luogo prescelto facendo attenzione che sia conforme a quanto previsto nel presente manuale Si raccomanda di adagiare la caldaia sul pavimento con la massima cautela evitando qualsiasi urto e di posizionarla nella zona preposta inoltre indispensabile verificare la portata del pavimento in funzione del peso della caldaia in caso contrario consultare un tecnico specializzato Una volta rimosso l imballo di protezione fare molta attenzione a non danneggiare le parti meccaniche ed elettriche con urti o schizzi d acqua L ambiente di installazione deve essere sufficientemente ventilato per consentire l evacuazione di eventuali piccole perdite di fumo di combustione L apparecchio idoneo al funzionamento in ambiente tecnico con temperatura minima non inferiore a 0 C e viene fornito completo della funzione antigelo che attiva il funzionamento della pompa di riscaldamento x temperature dell acqua contenuta nell impianto inferiori a
241. para impedir que las eventuales p rdidas de humo salgan al ambiente Si no se alcanza un cierto valor de vac o o si la salida de humos est atascada el vacuostato detecta la falta de depresi n en la c mara de combusti n o el deb metro detecta la ausencia del flujo de aire comburente En tal caso el control electr nico detiene el motor de rotaci n del sinf n y advierte de la anomal a con un mensaje en el panel de mandos AL 8 FALTA DEPRES o AL 9 TIRO INSUF 3 3 Seguridad contra sobrepresiones en la c mara de combusti n En caso de sobrepresi n de los humos en la c mara de combusti n y en los conductos de evacuaci n los humos se descargan a trav s de las v lvulas de seguridad situadas sobre la puerta del cenicero Durante el funcionamiento normal estas v lvulas est n cerradas por su propio peso y por la depresi n de la c mara y garantizan la estanqueidad ante una eventual salida de humos A Controle peri dicamente el cierre el estado general y el funcionamiento de las v lvulas 3 4 Sobrecalentamiento termostatos de seguridad En la pared inferior del dep sito precisamente en el conducto de pellets y en la cima de la c mara t rmica hay dos sondas de temperatura conectadas a sendos termostatos de seguridad que en caso de calentamiento excesivo desactivan autom ticamente la alimentaci n del pellet En este caso el extractor de humos o los ventiladores siguen funcionando para enfriar r pidamente la caldera La
242. parameter Parameter value WORK Display temperatures Fume temperature Water temperature air 7 C 40 Decrease the water and ambient thermostat C water SET TEMPERATURE temperature value SET H20 air Temperature 30 C 80 2 Decrease temperature Selected PROGRAMMING Decrease the selected parameter parameter Parameter value WORK Display stove operation status en fume fan speed Access the SET temperature and the user 3 Set Menu and technician parameters menu with SET parameter Temperature value successive pressing WORK Press for 2 seconds to turn the stove on or Display current off if off or on respectively status 4 ON OFF Reset BLOCK Reset the stove returning it to off status OFF Use to exit the programming menu at any PROGRAMMING stage of the modification Modifications are saved Decrease the power or the DHW storage SET DHW 5 Decrease power WORK OFF tank water thermostat Temperature value if Power level t t 1 5 enabled emperature Increase the power or the DHW storage SET DHW 6 Increase power WORK OFF tank water thermostat Temperature value if Power level 1 5 enabled temperature External contact Chrono The Figure opposite describes the meaning of the status Heater indicators in the left part of the display Activation of one of the segments on the display signals activation of the corresponding device according to the list opposite Auger Fume extractor DHW circuit activation HEATING cir
243. per consentire la corretta e completa evacuazione dell aria dallo sfiato portando in pressione il circuito per un impianto a vaso chiuso da 1 1 a 1 5 bar al termine dell operazione chiudere il rubinetto di carico e assicurarsi che tutte le valvole di sfiato abbiano scaricato l aria della parte di competenza dell impianto La realizzazione di un impianto di riscaldamento con la relativa installazione della caldaia deve rispettare A tutte le Normative Nazionali Regionali Provinciali e locali vigenti e previste dal paese in cui viene effettuato l impianto 2 9 2 Caratteristiche acqua d impianto Le caratteristiche chimico fisiche dell acqua dell impianto e di reintegro sono importanti per il corretto funzionamento e la durata della caldaia infatti con l utilizzo di acqua di scarsa qualit l inconveniente pi frequente rappresentato dalle incrostazioni calcaree che causano la riduzione dello scambio termico e generano fenomeni di corrosione Si consiglia pertanto di verificare la qualit dell acqua e nelle condizioni sottoelencate di provvedere ad un trattamento elevata durezza dell acqua gt 20 considerevoli quantit d acqua di reintegro o riempimenti successivi impianti di una certa complessit e grandezza 2 9 3 Impianto sanitario Per collegare la caldaia ad un impianto sanitario si consiglia di rivolgersi ad un tecnico competente al fine di ottimizzare al meglio i collegamenti idraulici e le prestazioni dell intero
244. por debajo del an calefacci n limite inferior establecido ea en pantalla Controlar que la temperatura del agua baje de 0 C Se ala que la caldera ha eo supera LE 1800 horas Las operaciones de limpieza LLAMAR funcionamiento desde la ltima 80 de mantenimiento mantenimiento extraordinario y rearme SERVICE NA extraordinario deben ser realizadas por un centro de intervenci n de n asistencia autorizado mantenimiento La empresa se reserva el derecho a realizar modificaciones t cnicas o est ticas de los productos en cualquier momento y sin preaviso Las figuras y medidas los esquemas y dem s informaci n tienen solo valor indicativo 160 DOMUSFIRE C29 C35 C39 8 ANEXOS COLA INFORMAZIONI MARCATURA CE CE MARKING INFORMATION 13 Tipologia Type Modelo Model Combustible Fuel Potencia t rmica introducida Heating input COLA TUV K8552012T1 K8552012T2 K8552012S3 EN 303 5 2012 Caldaia a pellet Heating Boiler DOMUSFIRE DOMUSFIRE DOMUSFIRE c29 C35 c39 Pellet di legno Wood pellet UNI EN14961 2_classe A1 29 0 6 4 34 4 6 4 38 3 6 4 Potencia termica al agua Water heating output 274 5 78 324 5 78 349 5 78 Rendimiento t rmico Efficiency Consumo horario Fuel consumption Emisiones de CO al 10 O2 Emission CO at reference 10 O2 94 45 90 14 94 18 90 14 91 32 90 14 6 1 32 7 1 1 32 7 9 1 32 0
245. possible que lorsque la temp rature de l eau sera descendue en dessous d une valeur pr d finie saisie dans le tableau des param tres 2 C par d faut Les commandes manuelles effectu es en utilisant le tableau de commande sont prioritaires par rapport la programmation Si elle est sur OFF la chaudi re ne dispose pas du mode VEILLE et elle fonctionne normalement avec la fonction MODULATION lorsque la temp rature d passe la valeur de CONSIGNE Chargement initial Une fois configur e cette fonction permet de valider le fonctionnement du motor ducteur chaudi re teinte ou froide pour permettre de pr charger les granul s en 90 secondes La fonction d marre en appuyant sur le bouton P1 et s arr te en appuyant sur le bouton P4 Type de granul s Lorsque la fonction est valid e appuyer sur les boutons P1 ou P2 pour augmenter ou r duire la quantit de granul s afin d optimiser la consommation et la combustion en fonction du type de granul s utilis s Chargement initial vis sans fin 2 Cette fonction permet de valider le fonctionnement du motor ducteur du r servoir suppl mentaire pour un pr chargement programm Appuyer sur le bouton P1 pour d marrer le chargement et appuyer sur le bouton P4 pour l interrompre 4 6 3 Menu 03 Valeurs de l utilisateur Ce menu permet de proc der aux r glages suivants Langue Cette option permet de s lectionner la langue de dialogue parmi celles propos es dans le menu nota
246. pour une dur e pr d finie La fen tre de dialogue affichera l indication ATTENTE REFROID Fen tre de dialogue 86 DOMUSFIRE C29 C35 C39 COLA 4 12 Menu Appuyer sur la touche P3 SET pour entrer dans le menu qui propose diff rentes options et diff rents niveaux permettant d acc der aux param trages de l lectronique de commande Le tableau ci apr s r sume la structure du menu avec les seules options disponibles pour l utilisateur Manu er os M 1 1 Valide Chrono M 1 1 01 Valide Chrono ON OFF Chrono M 1 2 01 Chrono Jour M 1 2 02 Start 1 Jour M1 2 Program Jour M 1 2 03 Stop 1 Jour M 1 2 04 Start 2 Jour M 1 2 05 Stop 2 Jour M 1 3 01 Chrono Semaine ON OFF M 1 3 02 Start Prog 1 M 1 3 03 Stop Prog 1 M 1 3 04 Lundi Prog 1 M 1 3 05 Mardi Prog 1 M 1 3 06 Mercredi Prog 1 M 1 3 07 Jeudi Prog 1 M 1 3 08 Vendredi Prog 1 M 1 3 09 Samedi prog 1 M 1 3 10 Dimanche Prog 1 M 1 3 11 Start Prog 2 M 1 3 12 Stop Prog 2 M 1 3 13 Lundi Prog 2 M 1 3 14 Mardi Prog 2 M 1 3 15 Mercredi Prog 2 M 1 3 16 Jeudi Prog 2 M 1 3 17 Vendredi Prog 2 Program M 1 3 18 Samedi prog 2 M1 3 Hebdomadaire M 1 3 19 Dimanche Prog 2 M 1 3 20 Start Prog 3 M 1 3 21 Stop Prog 3 M 1 3 22 Lundi Prog 3 M 1 3 23 Mardi Prog 3 M 1 3 24 Mercredi Prog 3 M 1 3 25 Jeudi Prog 3
247. pr sente l avantage d unir la chaleur g n r e par la combustion du bois a la gestion automatique de la temp rature de l eau avec possibilit de programmer les allumages et les arr ts sur une semaine avec la connexion d un thermostat et ou d un chronothermostat pour la commande a distance de ces m mes fonctions Pour une utilisation s re et fiable de la chaudi re respecter les points suivants il est possible de sentir de mauvaises odeurs lors de la premi re mise en service Par cons quent a rer correctement la piece pendant la premi re p riode de fonctionnement le remplissage du r servoir doit se faire exclusivement avec des granul s Pendant cette op ration viter que le sac n entre en contact avec les surfaces chaudes de la chaudi re ne pas introduire dans le r servoir d autres types de combustible que les granul s conformes aux prescriptions ne pas utiliser la chaudi re comme incin rateur de d chets la porte du foyer doit toujours tre ferm e quand la chaudi re est en marche les joints de la porte du foyer et du cendrier doivent tre contr l s r guli rement pour viter toute infiltration d air le foyer doit toujours tre propre pour garantir un bon fonctionnement et un rendement thermique efficace le nettoyer chaque chargement de granul s il est important au premier allumage de ne pas surchauffer la chaudi re mais de faire monter progressivement la temp rature en programmant des temp r
248. que d installation une installation de chauffage doit disposer de tous les composants n cessaires au r glage au contr le et la s curit afin de garantir le fonctionnement correct et fiable elle doit galement disposer de vannes d arr t et de clapets anti retour afin d isoler la chaudi re pour les op rations de maintenance et ou les contr les Il existe deux types d installation VASE FERME et a VASE OUVERT dans le cas pr sent les deux types sont compatibles avec notre appareil condition d installer tous les composants n cessaires au r glage au contr le et la s curit pr vus par les normes en vigueur en mati re d installation Le circuit hydraulique de chauffage de la chaudi re granul s comprend notamment un circulateur une soupape de s ret un purgeur des sondes de temp rature et un transducteur de pression Dans le cas d installation de chauffage multizones il faudra imp rativement pr voir une unit lectronique avec gestion multizones disponible sur demande Pour viter le retour d eau froide dans la chambre thermique durant la phase de chauffe d une chaudi re combustible solide il est conseill d installer une SOUPAPE THERMOSTATIQUE AUTOMATIQUE disponible sur demande afin d am liorer la combustion et de prolonger la dur e de vie de la chaudi re mais aussi pour r duire les condensats dans les conduits et viter le plus possible la formation de suies Avant de raccorder la chaudi re a
249. r W FROSTGEFA ird ausgel st wenn die Die Regelung des Kessels misst im Heizkreis zu bewegen HR Wassertemperatur unter eine eine Wassertemperatur unter 6 C Die Wassertemperatur berwachen T D H er bestimmte Temperatur f llt und meldet dies auf dem Display die nicht unter 0 C sinken darf SERVICE Wird ausgel st wenn der Kessel seit Die Arbeiten f r au erordentliche l der letzten Wartung 1800 Stunden in Anforderung der uBerordentlichen Reinigung Wartung und R cksetzung FALLIG Betrieb war Wartung m ssen vom Vertragskundendienst durchgef hrt werden 128 DOMUSFIRE C29 C35 C39 COLA 8 ANHANGE INFORMATIONEN ZUR CE KENNZEICHNUNG CE MARKING INFORMATION TUV K8552012T1 K8552012T2 K8552012S3 12 303 5 2012 KESSEL Heating Boiler Sen Holzpellets Wood pellet UNI EN14961 2_classe A1 146 7 116 4 147 1 116 4 130 2 116 4 T sr ull hermische leistung eingfuhrt Heating input armeleistung Wasser Water heating output hermischer Wirkungsgrad ficiency Stundi Verbrauch Fuel consumption Emission bei 10 Oz nHm Emission bei 10 O mission CnHm at reference 10 O INOx Emission bei 10 O mission NOx at reference 10 O taubemission bei 10 Emission dust at reference 10 O Emission bei 139602 nHm Emission bei 1396 O NOx Emission bei 13 mission NOx at reference 13 O gt taubemission bei 13
250. r ttlers in unterer Postion des Kesselbetriebs 123 DOMUSFIRE C29 C35 C39 6 WARTUNG 6 1 Vorwort COLA Die Eingriffe an Innenteilen des Kessels m ssen von autorisiertem Fachpersonal durchgef hrt werden wenden Sie sich hierf r bitte an den nachstgelegenen Kundenservice Vor jedem Eingriff am Kessel muss sichergestellt werden dass der Netzstecker gezogen und der Kessel erkaltet ist 6 2 Ausbau der Kesselverkleidung 124 Zeichenerklarung 1 Pelletsklappe 2 Mittlere Abdeckungen 3 Seitliche Verkleidung 4 Vordere Abdeckung 5 Isolierte AuBent r 6 R ckwandverkleidung Zeichenerkl rung 1 Knauf mit Gewindestange 2 Verlangerungszapfen Turbulatorenr ttler 3 Mutter zum Fixieren der Buchse 4 Zapfen Gleitlager 5 AuBenabdeckung 6 Oberer Hitzeschutz 7 Mittlere Schutzabdeckung 8 Oberer Vermiculitschutz 9 Seitlicher Vermiculitschutz 10 AuBerer Hitzeschutz der Kammer 11 Abdeckung und Halterung der Schutzeinr 12 Turbulatorenhalterung 13 Turbulatoren 14 Feuerraumt r 15 Sicherheitsventil 16 Aschet r 17 Aschekasten 18 Heizkammer DOMUSFIRE C29 C35 C39 COLA Explosionszeichnungen von 1 Baugruppe Brenntopf 2 Baugruppe Saugzuggeblase 3 Baugruppe F rderschnecke Legende 1 Brenntopf 2 Brenntopfhalter 3 Inneres Leitblech 4 Luft Ansaugrohr 5 Heizwiderstand 6 Dichtunge
251. r Feuerraumt r betrieben werden Die Dichtungen der Feuerraum und Aschet r sind regelm ig zu pr fen um Luftinfiltrationen auszuschlie en Um einen guten Wirkungsgrad und einen einwandfreien Betrieb zu gew hrleisten muss der Brenntopf vor jeder Pelletbeschickung gereinigt werden Bei der ersten Inbetriebnahme darf der Kessel nicht berhitzt werden sondern muss allm hlich durch Einstellen niedriger Temperaturen auf Betriebstemperatur gebracht werden siehe Absatz Temperatureinstellung Aufgrund der W rmeausdehnung kann der Kessel beim Einschalten w hrend des Betriebs und beim Ausschalten leichte Ger usche von sich geben 4 2 Beschreibung des Bedienpanels Das Bedienpanel besteht aus einem hinterleuchteten LCD Display der Ein Ausschalttaste P4 der Funktionstaste SET MENU den vier Men tasten P1 P2 PRPO und 7 LEDs die den Betriebszustand des Kessels anzeigen Statusanzeigen Display Anzeigen Hinterleuchtetes LCD Display Einstelltasten Tasten f r Einstellung und Wahl IR Empf nger Vom Bedienpanel kann der Kessel ein und ausgeschaltet der Betrieb geregelt das Regel und das Wartungsprogramm eingerichtet werden Auf dem Display werden alle Informationen ber den Betriebszustand des Kessels angezeigt Die Men s werden wie folgt aufgerufen Die Taste SET P3 dr cken mehrmals die Tasten P5 P6 dr cken um durch die verschiedenen Men s zu bl ttern eine der Tast
252. r la porte ext rieure tirer vers l ext rieur Pour ouvrir la porte ins rer la poign e fournie et tourner dans le sens des aiguilles d une montre Poign e permettant d ouvrir fermer la porte du foyer et la porte du cendrier Ouverture sens anti horaire Fermeture sens horaire 1 5 Combustible et usage pr vu Les chaudi res a granul s fonctionnent exclusivement avec des granul s pastilles d essences de bois diff rentes conform ment a la norme DIN plus 51731 ou UNI CEN TS 14961 ou O Norm M 7135 ayant les caract ristiques suivantes Pouvoir calorifique mini 4 8 kWh kg 4180 kcal kg Densit 680 720 kg m Humidit maxi 10 de son poids Diam tre 6 0 5 mm Taux de cendres maxi 1 5 de son poids Longueur mini 6 mm maxi 30 mm Composition 100 bois non trait de l industrie du bois ou post consommation sans adjonction de substances liantes et sans corce conforme aux normes en vigueur Emballage dans des sacs en mat riau compatible avec l environnement ou biod gradable ou en papier Le r servoir granul s se trouve l arriere de la chaudi re Le volet d ouverture se trouve dans la partie sup rieure et le chargement se fait manuellement uniquement lorsque la chaudi re est teinte en faisant attention a ne pas faire sortir les granul s du r servoir L utilisation de granul s de bois ayant des caract ristiques diff rentes de celles des granul s utilis s pour le test lo
253. r que se indica en la placa de identificaci n de la caldera y en el apartado de datos t cnicos de este manual Antes de un per odo de inactividad de la caldera se recomienda desconectarla de la corriente el ctrica interruptor diferencial Compruebe que la instalaci n el ctrica sea conforme a las normas y est dotada de puesta a tierra e A El cable de alimentaci n no debe tocar nunca el tubo de salida de humos de la caldera 139 DOMUSFIRE C29 C35 C39 COLA 2 7 Esquema el ctrico SEG PELLETS AS DOBLE X 3 V AS PARA AS SINF N DEP SITO AUX VV SINF N INT SEG H20 Ja In o n rez 1 o Le 621 Torr U Lel 1 ULe l Ule SZ1lOZI1385Zr4 1173N09 D E eJ e ae KC a E e e l E e ZT STE 00000000 H H 1 0 10 GND 5 ENZ CNIG IR SR a 2 H 791435 Y 0000 le re Sw 3 mE HUMOS AA HM Lac aja 2 EN p ele 20000000 m m E SE Pir vss DEB METRO AV IdSId 20 Y Tov zpv spy vv SII
254. r technischen Tabelle des Handbuches und auf dem Typenschild angegeben Auf die Art des FuBbodens und der Decke des Daches des Aufstellungsraums achten bei empfindlichen und entflammbaren Materialien wird die Verwendung geeigneter W rmed mmplatten oder W rmemembranen empfohlen siehe Abschn 2 2 3 2 Sicherheitsvorrichtung Abgasf hrung Bei normalem Betrieb herrscht in der Brennkammer Unterdruck was das Austreten von Rauch in den Raum verhindert Wird der erforderliche Unterdruck nicht erreicht oder ist der Rauchabzug verstopft erfasst der Unterdruckw chter den Unterdruckmangel in der Brennkammer oder der Luftmassenmesser erkennt das Fehlen der Verbrennungsluftzufuhr ber die elektronische Regelung wird der Schneckenmotor ausgeschaltet und der Benutzer mit einer der folgenden Meldungen auf dem Display auf die St rung hingewiesen AL8 KEIN UNTERDRUCK oder AL9 UNGENUGENDER ZUG 3 3 Uberdruckventil in der Brennkammer Eventuelle und oder pl tzliche berdr cke der Verbrennungsgase in der Kammer und in den Rauchabzugsleitungen werden durch das Offnen der Sicherheitsventile die sich ber der Aschet r befinden abgelassen Wahrend des normalen Betriebs sind diese Ventile durch das eigene Gewicht und den Unterdruck der Kammer geschlossen und verhindern dadurch einen eventuellen Rauchaustritt A Die Sicherheitsventile regelmaBig auf ihre Funktionst chtigkeit und ihren Zustand berpr fen 3 4 Uberhitzung Sicherheitsthermostate
255. re le feu avec des extincteurs A Appeler imm diatement les sapeurs pompiers Ne pas utiliser de jets d eau pour teindre le feu 80 DOMUSFIRE C29 C35 C39 COLA 3 SYSTEMES DE PROTECTION DE LA CHAUDIERE 3 1 Distance de s curit par rapport aux mat riaux inflammables Installer l appareil une distance de s curit minimale par rapport tout mat riau inflammable afin d viter tout risque d incendie conform ment aux indications pr sentes sur la fiche technique du manuel et sur la plaque de l appareil Faire attention au type de sol et de plafond rev tement du local en cas de mat riaux d licats et inflammables utiliser des panneaux ou des diaphragmes thermiques appropri s voir parag 2 2 3 2 S curit pour l vacuation des fum es Normalement la chambre de combustion fonctionne en d pression et garantit l tanch it contre toute fuite de gaz dans l environnement En cas de valeur de d pression insuffisante ou de conduit de fum e obstru le vacuostat de s curit d tecte le manque de d pression l int rieur de la chambre de combustion ou le d bitm tre d c le l absence de flux d air comburant et arr te le fonctionnement du moteur de rotation de la vis sans fin par l interm diaire de l unit Le message AL8 MANQUE DEPRESS ou AL9 TIRAGE INSUFF s affichera sur le tableau de commande 3 3 S curit en cas de surpression dans la chambre de combustion En cas de surpression inattendue
256. re o plostre x sonltorlo Circolotore Valvola dl kllanclamento circulto Vaso di espansione a membrano 0 Valvola termostatica automatica Rublnetto Valvola d Intercettazlone Sensore di sicurezzo T gt 85 C Valvola di non ritorno Sensore di temperatura acqua Sflato arla termocomera circulto Sensore di pressione circuito Valvola di sicurezza max 3 bar od Volvole da inserire nell impianto durante l installazione non 0 Valvola dl sicurezza max 6 bor fornite con l apparecchio 17 DOMUSFIRE C29 C35 C39 Schema idraulico Caldaia a pellet con scambiatore Termocamera Pellet Caldaia a pellet Termostato our gt S Control UN system 7 I LEGENDA O Rulolnetto ol scarico D Flussostato 2 Sensore di pressione manometro a Scamblatore a plostre x sanltarlo 4 Circolotore 3 Valvola di bllanclamento clrculto 5 Vaso di espansione membrano 3 Volvola termostotico automatica Rublnetto Valvola d Intercettazlone Sensore di sicurezza gt 85 C e Valvola dl non rltorna Sensore dl temperatura acqua 8 Sflato arla termocamera clrculto Sensore di pressione circuito 3 Valvola dl sicurezza P max 3 bar Pe Valvole da inserire nell impianto E Alinentozione acquedotto F1 2 durante l installazione non 0 Walvola dl sicurezza P max 6 bor fornite con l apparecchio PI m E 2 10 Pronto intervento Per ogni evenienza consig
257. remessa 4 2 Descrizione del pannello comandi 4 3 Accensione 4 3 1 Controllo prima dell accensione 4 3 2 Fase di avvio 4 4 Fase di lavoro 4 4 1 Modifica impostazione temperatura acqua 4 4 2 Riavvio da STAND BY 4 4 3 Pulizia del braciere 4 4 4 Acqua calda sanitaria con scambiatore rapido 4 4 5 Acqua calda sanitaria con bollitore ad accumulo 4 4 6 Impianto con puffer accumulatore di calore 4 5 Spegnimento COLA 4 6 Menu 4 6 1 menu 01 set crono 4 6 2 menu 02 regolazioni utente 4 6 3 menu 03 set utente 4 6 4 men 04 stato caldaia 4 6 5 menu 05 regolazioni installatore 4 7 Termostato cronotermostato esterno 4 8 Periodo di inattivita fine stagione 5 PULIZIA DELLA CALDAIA 5 1 Pulizia braciere portabraciere 5 2 Pulizia contenitore cenere 5 3 Pulizia estrattore fumi e camera di combustione 5 4 Pulizia debimetro 5 5 Pulizia raccordo fumi canna fumaria 5 6 Pulizia scambiatori con il dispositivo scuoti turbolatori 6 MANUTENZIONE 6 1 Premessa 6 2 Smontaggio rivestimento caldaia 6 3 Componenti interni della caldaia 6 4 Componenti elettrici 6 5 Componenti idraulici di serie 7 RICERCA GUASTI 7 1 Gestione degli allarmi 8 ALLEGATI 8 1 Informazioni marcatura CE 8 2 Certificato di garanzia 8 3 Riepilogo AVVERTENZE GENERALI 8 4 Riepilogo PULIZIE GENERALI DOMUSFIRE C29 C35 C39 COLA 1 AVVERTENZE GENERALI 1 1 Introduzione Gentile Cliente Desideriamo innanzi tutto ringraziar
258. rico fumi Fume outlet pipe Alimentazione elettrica Electrical power 6 1 32 0 005 0 040 6 7 18 8 146 7 116 4 24 1 9 5 0 004 0 029 4 9 13 78 106 8 84 6 17 6 6 9 19 66 12 69 5 7 1 1 32 0 007 0 040 7 9 1 32 0 009 0 040 6 6 18 8 147 1 116 4 23 6 9 5 6 7 18 8 130 2 116 4 24 5 9 5 0 005 0 029 0 006 0 029 4 8 13 78 107 84 6 17 2 6 9 4 9 13 78 94 7 84 6 17 8 6 9 19 22 12 69 19 86 12 69 ee Isi ce 10 14 521 7 130 4 148 6 62 6 16 3 5 4 0 10 0 14 624 7 156 2 159 5 62 6 182 54 230V 50Hz 6A Assorbimento elettrico Rated input power Dimensioni d ingombro HxLxP Dimensions HxLxP Peso a vuoto Weight Accensione Start 476 Stand by 4 P nom 160 P rid 153 700x698 275 72 1300x700x698 275 ati cile A alla Potenza nominale e Potenza ridotta Nominal output and Reduced output Il consumo di pellet pu variare dal tipo di pellet utilizzato Pellet consumption can vary according to the type of pellets used COLA sr Vale del Lavoro 7 9 37040 Arcale VR Italy Tel 045 7635790 045 6144043 Cod Fisc P IVA e iscr Reg 180230 Capitale Sociale Euro DO iv REA VR 301021 Socio Unico Fax Amministrazione 045 je 045 7639032 Fax Assistenza 045 7639030 Fax Logistica 045 6144048 FERRER emal intofdansemocola com
259. rios La caldera debe utilizarse exclusivamente para calentar agua a una temperatura inferior a la de ebullici n El equipo instalado seg n las normas funciona con cualquier condici n clim tica exterior No obstante en situaciones cr ticas como viento fuerte o heladas pueden actuar los dispositivos de seguridad que apagan la caldera 132 DOMUSFIRE C29 C35 C39 COLA Datos t cnicos de la caldera mod DOMUSFIRE C29 C35 C39 Caldaia a pellet Heating Boiler C29 C35 C39 DOMUSFIRE DOMUSFIRE DOMUSFIRE Pellet di legno Wood pellet UNI EN14961 2_classe A1 a introducida 29 0 64 344 64 38 3 64 eating Sage a Potencia t rmica al agua 274 5 78 32 4 5 78 34 9 5 78 Water heating output Rendimiento t rmico 94 45 90 14 94 18 90 14 91 32 90 14 kg h 6 1 32 7 1 1 32 7 9 1 32 Emission CO at reference 10 O2 Emisiones de CnHm al 10 O 5 Emission CnHm at reference 10 O m KR Emisiones de NOx al 10 O Emission NOx at reference 10 O Emisiones de polvo al 10 O Emission dust at reference 10 U gt Emisiones de CO al 13 02 Emission CO at reference 13 Emisiones de CnHm al 13 O Emission CnHm at reference 13 O gt Emisiones de NOx al 13 O Emission NOx at reference 13 O misiones de polvo al 13 O Emission dust at reference 13 O gt Total de emisiones de particulas PPBT al 13 O Total dust emission PPBT at ref 13 O Temperatura max a
260. rizado La c mara de combusti n est Controlar la limpieza del tubo de sucia humos y de la c mara de combusti n El conducto de humos est Comprobar el cierre herm tico de la AL9 Se ala que el flujo de aire atascado puerta comburente est por debajo La puerta de la c mara est Comprobar el cierre de las v lvulas TIRO INSUF del l mite especificado abierta antiexplosi n Las v lvulas antiexplosi n Toda otra operaci n de est n abiertas atascadas restablecimiento debe ser efectuada El deb metro est averiado por un centro de asistencia autorizado Se ala que la presi n del El transductor de presi n ALE montado el circuito _ agua no esta el campo de SI TOR Localizar la causa del problema y valores correcto na Una restablecer la presi n correcta PRES AGUA o El sistema se seta presi n inferior o superior a los parad l mites establecidos El termostato de seguridad ha ALA Se ala que ha actuado el detectado una temperatura Localizar la causa del termostato de seguridad del superior al l mite especificado sobrecalentamiento SEGUR agua de la c mara t rmica para el sobrecalentamiento del Rearmar con el bot n H20 por T gt 95 C agua de la c mara t rmica y ha correspondiente el termostato que ha El sistema se para bloqueado el funcionamiento detectado el sobrecalentamiento del motorreductor AL rene ute a aaao Las operaciones de restablecimien
261. rmostat sup rieure au seuil de r glage FRE NEU CINE excessif 2 nome D bloquer le thermostat qui est S CURIT de s curit de la temp rature du cause de la surchauffe de la ee THERMIQUE canal de la vis sans partie inf rieure du r servoir et a Le syst me est arr t donc bloqu le fonctionnement du motor ducteur surchauffe en agissant sur le bouton de r armement 96 DOMUSFIRE C29 C35 C39 COLA AL 8 En marche la chaudi re rel ve La chambre de combustion est encrass e Le conduit de fum e est obstru V rifier l tat de propret du conduit de fum e et de la chambre de combustion V rifier la fermeture herm tique de la en n 3 ABSENCE une pression inf rieure au seuil La porte de foyer n est pas V rifier la fermeture des clapets anti P de tarage du vacuostat ferm e explosion DEPRESS Le syst me est arr t Les clapets anti explosion sont D autres op rations de ouverts coinc s r tablissement du fonctionnement Le vacuostat est d fectueux normal doivent tre effectu es par un centre d assistance V rifier l tat de propret du conduit La chambre de combustion est de fum e et de la chambre de encrass e combustion 8 AL 9 Cette alarme se d clenche Le conduit de fum e est obstru SEH la fermeture herm tique de la TIRAGE lorsque le flux d air comburant se La porte de foyer n e
262. roductos de la combusti n Requisitos t cnicos del SOMBRERETE debe tener secci n equivalente a la de la chimenea la secci n til debe ser como m nimo el doble de la secci n interior de la chimenea debe impedir la entrada de lluvia y cuerpos extra os y asegurar en cualquier condici n atmosf rica la evacuaci n de los productos de la combusti n debe garantizar una adecuada dispersi n de los productos de la combusti n y estar situado fuera de la zona de reflujo no debe estar provisto de medios mec nicos de aspiraci n A La salida directa de los productos de la combusti n debe hacerse en la cubierta del inmueble esta prohibido dirigirla a espacios cerrados incluso sin techo 2 5 Control de la posici n del brasero y de los turbuladores Antes de encender la caldera es importante controlar que el brasero est en la posici n correcta y enganchado en las fijaciones Controle tambi n que los pomos para sacudir los turbuladores est n bajados en reposo La posici n incorrecta del brasero o de los turbuladores provoca fallos de funcionamiento y una formaci n excesiva de polvos y material inquemado A A cada encendido del equipo controle la posici n del brasero y del sacudidor de los turbuladores 2 6 Conexi n el ctrica Conecte el cable de alimentaci n el ctrica por una parte a la toma posterior de la caldera y por la otra a una toma de corriente mural La tensi n de la red el ctrica debe tener el valo
263. rs du premier allumage implique un nouvel ajustement des param tres de chargement des granul s dans la chaudi re Noter que cette intervention n est pas couverte par la garantie Les granul s doivent tre stock s dans un lieu sec et prot g contre l humidit Aux fins d une combustion r guli re et efficace il n est pas possible de charger manuellement les A granul s ou autres combustibles dans le foyer Avec le temps la poussi re s accumule dans le r servoir granul s ce qui pourrait compromettre l alimentation r guli re il est donc conseill d liminer la poussi re avant de remplir le r servoir granul s Eviter de remplir le r servoir de combustibles non conformes Eviter le chargement de corps trangers tels que r cipients bo tes sachets m taux etc dans le r servoir L utilisation de granul s de mauvaise qualit et non conformes peut endommager et compromettre le fonctionnement de l appareil et de la chaudi re annule la validit de la garantie et d gage le constructeur de toute responsabilit 1 6 Accessoires fournis La fourniture comprend cordon d alimentation lectrique manuel d installation d utilisation et d entretien cl d ouverture de fermeture 72 DOMUSFIRE C29 C35 C39 COLA 1 7 Normes de r f rence Norme UNI 10683 2012 elle fixe les exigences essentielles concernant l installation des g n rateurs de chaleur a bois ou a d autres biocombustibles so
264. s lectriques 6 5 Composants hydrauliques de s rie 7 RECHERCHE DES PANNES 7 1 Gestion des alarmes 8 ANNEXES 8 1 Informations relatives au marquage CE DOMUSFIRE C29 C35 C39 COLA 1 RECOMMANDATIONS GENERALES 1 1 Introduction Cher Client Nous vous remercions de la confiance que vous nous avez accord e en achetant ce produit Nous vous invitons a lire et a suivre attentivement les conseils fournis par ce manuel d installation d utilisation et d entretien pour exploiter au mieux les qualit s de cet appareil 1 2 Comment utiliser ce manuel La soci t COLA s r l se r serve d apporter des modifications techniques ou esth tiques a ses produits a n importe quel moment et sans pr avis Les op rations d installation d utilisation et d entretien de la chaudi re doivent satisfaire les exigences de ce manuel des normes europ ennes nationales et locales Toutes les configurations les dessins les mesures et les sch mas sont fournis a titre d exemple Ce manuel s adresse l utilisateur de l installation de chauffage ECS et constitue une partie int grante et essentielle de l appareil si l appareil doit tre vendu ou transf r un autre propri taire ou s il doit tre install un autre endroit s assurer que le manuel accompagne l appareil afin qu il puisse tre consult ult rieurement tout moment En cas de perte ou de d t rioration de ce manuel demander une copie de celui ci au centre d assistance tec
265. seg n normas a trav s de un terminal inspeccionable La conexi n de varios aparatos a una misma chimenea debe estar autorizada por las normas locales y por el organismo de control de este tipo de sistemas Conectar la caldera a la aspiraci n mediante un tubo o toma de aire desde el exterior Conectar la caldera a una toma de corriente homologada de 230 V 50 Hz Controlar que la instalaci n el ctrica y las tomas de corriente puedan soportar la absorci n m xima del equipo indicada en la placa y en este manual La clavija de conexi n el ctrica debe ser f cilmente accesible Conectar el equipo a la instalaci n de calefacci n No utilizarlo en ning n caso sin la conexi n hidr ulica y sin cargar agua en la c mara t rmica y en la instalaci n equipo no debe ser utilizado por ni os ni por adultos que tengan limitadas sus capacidades f sicas sensoriales o mentales o que no cuenten con la experiencia y los conocimientos debidos salvo que est n instruidos o supervisados por otra persona que se haga responsable de su seguridad Vigilar a los ni os e impedir que jueguen con el equipo o en el local de instalaci n A Evitar que el cable de alimentaci n el ctrica y los cables de los sensores externos toquen las partes calientes del equipo A Est prohibido hacer funcionar el equipo con la puerta de la c mara de combusti n o del cenicero abiertas cerrar ni reducir la secci n de los conductos de
266. select ON to activate the function and display the relevant segment LED D When Daily Weekly or Week End programming is entered the appropriate segment LED C appears in the top right of the display Regarding selections and entering times use the buttons according to the table in par 4 2 By accessing the submenu DAY PROGRAM the daily chronothermostat functions can be enabled disabled and set It is possible to set two operation stages delimited by the times set according to the following table where the setting OFF tells the clock to ignore the command selection meaning possible values START1 activation time time OFF STOP1 deactivation time time OFF START2 activation time time OFF STOP2 deactivation time time OFF By accessing the submenu WEEK PROGRAM it is possible to enable disable and set the weekly chronothermostat functions The weekly programmer has 4 independent programs whose final effect consists of a combination of the 4 programmings The weekly programmer can be activated or deactivated also by setting OFF in the time field the clock ignores the corresponding command Carry out programming making sure not to overlap the A hours of activation and or deactivation on the same day in different programs By accessing the submenu WEEK END PROGRAM it is possible to enable disable and set the week end Saturday Sunday chronothermostat functions Activate WEE
267. set uam safety SAF safety thermostat overheating of the bottom part thermostat by pressing the The system is stopped of the hopper blocking gearmotor operation reset button 64 DOMUSFIRE C29 C35 C39 COLA Signalling Fault Possible causes Cures Check cleanness of the fume i ul duct and combustion chamber The combustion chamber is dirty i AL 8 In the work stage the boiler The fume duct is obstructed SC NEUMEN C OSING OI ME NO NEG detects a pressure below the The fire door is not closed Check closing ofthe PRESS vacuum switch setting threshold The overpressure valves are overpressure e Mee Stopped SE Other reinstatement operations y must be carried out by a service centre Check cleanness of the fume The combustion chamber is dirty CUN COEM AL 9 The fume duct is obstructed heck hemete closing Of Me Appears when the combustion The fire dooris not closed door INSUFF air flow is below a certain Check closing of the The overpressure valves DRAUGHT threshold open stuck overpressure valves Faulty air flow mietet Other reinstatement operations y must be carried out by a service centre ALE Occurs when the water pressure Occurs when the pressure Check the cause of the problem WATER does not come within the values transducer on the water circuit restoring the circuit pressure by for correct operat
268. sitivos de regulaci n control y seguridad indicados por las normas respectivas La caldera de pellets tiene en su interior el circuito hidr ulico de calefacci n compuesto de circulador v lvula de seguridad purgador de aire sondas de temperatura y transductor de presi n Se recuerda que si el sistema de calefacci n est dividido en zonas es indispensable instalar una centralita multizona que se suministra a pedido En las calderas de combustible s lido para evitar el retorno de agua fr a a la c mara t rmica durante la fase de calefacci n se aconseja montar una V LVULA TERMOST TICA opcional As se mejora la eficacia de la combusti n y la duraci n de la caldera al tiempo que se reduce la condensaci n en los tubos de humos con menos formaci n de incrustaciones y alquitr n Antes de conectar la caldera al circuito hidr ulico se deben lavar todos los tubos de la instalaci n para eliminar los posibles residuos del montaje que pueden comprometer el funcionamiento de los dispositivos de control regulaci n y seguridad Durante el transporte de la caldera las juntas de estanqueidad del sistema hidr ulico pueden aflojarse o moverse y causar p rdidas de agua tras la puesta en marcha Para evitarlo durante la carga de agua y a A las pocas horas de funcionamiento se recomienda controlar el apriete de las tuercas de fijaci n de circuladores y c mara t rmica y ventear el aire que haya quedado en la instalaci n 2 9 1 C
269. ssibile variare l intensit luminosa del display retroilluminato da un min pari a 0 ad un max di 100 Set Temp Boiler Puffer possibile scegliere la temperratura di SET dell accumulatore d acqua sanitario da riscaldamento o entrambi da un min di 40 C ad un max di 80 Delta Boiler Puffer Con questa selezione possibile impostare la differenza di temperatura tra lo spegnimento della caldaia e la successiva riaccensione da un min di 0 5 C ad un max di 20 C in funzione delle esigenze del cliente e o della tipologia d impianto Livello pellet Con la selezione impostata su ON possibile gestire il segnale di mancanza pellet un messaggio sul pannello MANCANO PELLET la gestione di un serbatoio aggiuntivo di ricarica pellet disponibile su richiesta Invece con la selezione OFF viene disabilitato l eventuale serbatoio aggiuntivo e sul pannello non compare nessun messaggio Attiva sanitario Con questa selezione e la predisposizione dell accessorio sanitario pompa scambiatore valvola possibile gestire l acqua sanitaria da boiler o da scambiatore attraverso il segnale proveniente da termostato o flussostato 27 DOMUSFIRE C29 C35 C39 COLA 4 6 4 Menu 04 stato caldaia Con tale selezione amp possibile visualizzare lo stato istantaneo della caldaia riportando la condizione di funzionamento dei vari dispositivi ad essa collegati per il monitoraggio sono disponibili diverse p
270. st pas V rifier la fermeture des clapets anti situe en dessous d un certain ferm e explosion INSUFF seuil Les clapets anti explosion sont D autres op rations de ouverts coinces r tablissement du fonctionnement Le d bitm tre est d fectueux normal doivent tre effectu es par un centre d assistance Cette alarme se d clenche Cette alarme se d clenche lorsque la pression de l eau ne lorsque le transducteur de ene AL E se trouve pas dans la plage de pression mont dans le circuit uv EC en PRESS EAU valeurs de fonctionnement hydraulique releve une pression press en Ge valeur de fonctionnement normal correct inf rieure ou sup rieure aux Le syst me est arr t limites pr d finies Cette alarme se d clenche en Le thermostat de s curit a relev V rifier la cause de ALA cas d intervention du thermostat une temp rature sup rieure au seuil l chauffement excessif S CURIT de s curit de la temp rature de de r glage cause de la surchauffe D bloquer le thermostat qui est l eau de la chambre de de de l eau de la chambre de intervenu pour cause de H20 combustion combustion et a donc bloqu le surchauffe en agissant sur le Le syst me est arr t fonctionnement du motor ducteur bouton de r armement AL b Cette alarme se EE L lectronique de commande Les op rations de r tablissement lorsque le motor ducteur j ERREUR fonctionne encontinuiet pendant rel ve que le relais de du f
271. stabilito inserito nella tabella parametri default 2 C comandi manuali da pannello comandi sono prioritari rispetto alla programmazione Con la selezione OFF la caldaia non attiva la modalit STAND BY e funziona normalmente attivando la funzione MODULAZIONE quando la temperatura supera il valore di SET Carico iniziale L impostazione di tale funzione consente di attivare il funzionamento del motoriduttore a caldaia spenta o fredda per un precarico pellet pari ad un tempo di 90 sec Si avvia con il pulsante P1 e si interrompe con il pulsante P4 Tipo Pellet Con la funzione attiva e la pressione dei pulsanti P1 o P2 si aumenta o si riduce il caricamento del pellet per ottimizzare il consumo e la combustione in funzione della tipologia del pellet utilizzato Carico iniziale coclea 2 L impostazione di tale funzione consente di attivare il funzionamento del motoriduttore relativo al serbatoio aggiuntivo per un precarico stabilito Si avvia con il pulsante P1 e si interrompe con il pulsante P4 4 6 3 Menu 03 Set utente Con tale menu possibile eseguire la seguente serie di settaggi Lingua Con questa selezione possibile selezionare la lingua di dialogo tra quelle disponibili inserite nel menu e precisamente ITALIANO FRANCESE INGLESE TEDESCO SPAGNOLO Cicalino Con questa selezione possibile attivare o disattivare la segnalazione acustica della caldaia Illuminazione Con questa selezione po
272. system must match that specified on the stove data plate and in the technical data section of this manual During stove idle periods it is advisable to remove the power cable differential switch in compliance with the current Standards Make sure the electrical system complies with the regulations and has an earth connection and A The power cable must never touch the stove exhaust pipe 45 DOMUSFIRE C29 C35 C39 COLA iagram d iring 2 7W d INOQ a gt Le EJ 9 d 318000 d ONILWSH 2 SNILV3H H3LINOI H HIONV H3ddOH IdANS y ST HO es CA STO AVS 13 T13d 2 010000028 5410511385 2 4 CE 1113N09 S J DE nm Lec mn a pi ml 991 SINI YALAW MOT HIV mm m m m msn LNI BNI 9NI SNI H20 PRESSURE TRANSDUCER EXT THERM EXT THERM PUFFER STORAGE TANK H20 PROBE HEATING H20 PROBE n z 2 z FUME PROBE TS m z BOILER PELLET LEVEL HOPPER PELLET LEVEL gt FLOW SWITCH
273. t If the boiler is in the AWAITING REQUEST stage it automatically turns on and goes to WORK mode Once the work temperature of the heating chamber water is reached the supply of water to the storage tank is activated When the storage tank SET temperature is met the BOILER converts the heating system residual heat for about 2 minutes and then if there is no other request goes to AWAITING REQUEST or MODULATION depending on the settings see par 4 6 4 If the boiler is in OFF status it does not turn on and does not provide the service 4 4 6 System with puffer heat accumulator This type of installation requires the use of an external thermostat which measures the puffer water temperature When the temperature drops below the SET external thermostat temperature the boiler display shows the message PUFFER WATER or STORAGE TANK WATER and the 2 LEDs respectively indicated by the tap and the radiator light up since it can meet the heating system and DHW request If the boiler is in the AWAITING REQUEST stage it automatically turns on and goes to WORK status and the supply of water to the puffer is activated when the work temperature of the heating chamber water is reached When the puffer SET temperature is met the boiler goes to AWAITING REQUEST make sure to set the STANDBY function to ON see par 4 6 4 If the boiler is in OFF status it does not turn on and does not provide the service 4 8 Shutting down To shut down the boiler
274. t supply in case of excessive heating In this case the extractor and or fans continue working allowing the unit to cool down rapidly The fault is displayed on the control panel with the message AL 7 THERMAL SAF In case of activation proceed as follows gt Allow the boiler to cool down for at least 45 minutes Reset the thermostat by pressing the button near the switch behind the boiler figure opposite after removing the protection and namely T1 heating chamber water temperature thermostat T2 pellet chute temperature thermostat Restart the boiler normally Pellet hopper thermostat activation temperature gt 85 Heating chamber thermostat activation temperature gt 95 C 3 5 Safety against flare back in the pellet chute The solutions preventing flare back are gt negative pressure in the combustion chamber see par 3 2 the siphon shape of the pellet chute gt the hopper temperature safety see par 3 4 3 6 Overcurrent protection device The unit is protected against overcurrent by 2A fuse s on the power supply of the main boiler switch located at the back 3 7 Water circuit overpressure safety Any overpressure of the water inside the chamber by P gt 3 bar is discharged through activation of the safety valve installed in the hydraulic system inside the stove A Do not tamper with the safety devices 3 8 Fume extractor fan failure If the fume extractor fan stops for any reason the electronic c
275. t the unit In case of persistent failed lighting contact the Service Centre 53 DOMUSFIRE C29 C35 C39 4 7 Work stage COLA After the STARTUP stage the boiler goes to the WORK mode which is the normal operation mode The user can adjust the heating power from the max value of 5 to a min of 1 with the buttons P5 and P DHW circuit function activation ON is displayed by the segment LED A Storage tank or Puffer H20 temperature Power set to 3 Button P6 Button P5 Water temperature Real power in work equal to 1 flashing Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of AN pellets Make sure the unit is off when loading pellets The pellet hopper lid must always remain closed it must only be opened when loading fuel The bags of pellets must be kept at least 1 5 m from the boiler 4 4 1 Modifying the water temperature setting To modify the water temperature just select the MENU 03 mode by pressing the button P3 Then use the buttons P1 and P2 to enter MENU M 3 6 and to set the desired temperature When the water temperature has reached the set value_ or the fume temperature has reached the set max value the power is automatically brought to the min value MODULATION status Heating chamber water pq m m When the fume temperature reaches a set max value the message MODULATE F appe
276. taga FAILURE operations must be carried out by a service centre AL 2 en Probe fault Reinstatement operations FUME En ne The probe is disconnected must be carried out by a PROBE BCE from the board service centre ic Too many pellets Adjust the pellet flow AL 3 above 280 C Reduced heat exchange Other reinstatement HOT FUMES The 5 awn 18 in the system operations must be carried out activated p by a service centre AL 4 Pe IUD The fume fan is blocked Reinstatement operations i Faulty speed control sensor must be carried out by a FAN FAIL E SCH procedure is No power to fume fan service centre Check pellets in hopper E TM The pellet hopper is empty Check the lighting AL 5 ii The heater is faulty dirty or not procedures NO IGNITION activated correctly positioned Other reinstatement Pellet load setting incorrect operations must be carried out by a service centre The pellet hopper is empty Check pellets in hopper AL6 The pellet loading gearmotor Adjust the pellet flow NO PELLETS Brazier not fed with pellets has to adjust Other reinstatement The gearmotor does not load operations must be carried pellets out by a service centre The safety thermostat has Ch Check the cause of excessive AL 7 Occurs in case of cutting in of detected a temperature above overheati THERMAL the auger duct temperature the setting threshold due to Re
277. tches to standby status and carries out the lighting start stage only if a request for heat is recognised e g to heat the water or for DHW if available Button P4 Dialogue box Water temperature The boiler carries out the startup stages in sequence according to the procedures defined by the parameters that manage levels and times reaching the work condition unless anomalies or alarms occur according to the following table status duration devices conditions for going to next status SO Fume igniter CY auger exch OFF OFF OFF OFF OFF ON OFF START PREHEAT 40 sec ON ON OFF OFF time elapsed 40 sec PELLET PRELOAD Pr40 ON ON ON OFF time elapsed Pr40 AWAITING FLAME Pr41 ON ON OFF OFF time elapsed Pr41 PELLET LOADING ON ON ON OFF fume temperature Pr13 FIRE PRESENT Pro2 OFF ON ON ON time elapsed Pr02 d ambient temperature SET temperature fume WORK Or EN CN CN temperature lt Pr14 ambient temperature lt SET temperature water WORK MODULATE er en CN an temperature gt water SET fume temperature lt Pr14 BRAZIER CLEANING Pr12 OFF ON ON ON with frequency Pr03 WORK OFF ON ON ON ON OFF to switch off FINAL CLEANING Pr39 OFF ON OFF Pr39 starts when Tfumes lt Pr13 After a certain time has elapsed if the fume temperature has not reached the permissible minimum value the boiler goes in alarm status Do not use flammable liquids to ligh
278. thermostat ext rieur pour mesurer la temp rature de l eau du puffer Lorsque la temp rature descend au dessous de la temp rature de CONSIGNE configur e sur le thermostat ext rieur l cran de la chaudi re affiche EAU PUFFER ou EAU BALLON et les 2 LED indiqu es respectivement par le robinet et par le radiateur s allument pour indiquer que l eau peut servir les circuits chauffage et ECS Si la chaudi re est en phase de DEMANDE D ATTENTE elle s allume automatiquement et se met en mode FONCTIONNEMENT lorsque l eau aura atteint la temp rature de service elle pourra arriver au puffer Lorsque la temp rature de CONSIGNE du puffer est atteinte la chaudi re se met en DEMANDE D ATTENTE mettre la fonction VEILLE sur ON voir parag 4 6 4 Si la chaudi re est en mode TEINT elle ne s allume pas et le service n est pas disponible 4 11 Extinction Pour teindre la chaudi re il suffit d appuyer environ 2 secondes sur le bouton P4 La vis sans fin est imm diatement stopp e et l extracteur des fum es est amen a fonctionner a une allure lev e L cran affiche l indication NETTOYAGE FINAL Ballon ou Puffer 4216 SEC 5355 nEEEQYAG Fi nRL Au terme de l op ration l cran affichera TEINT dans la fen tre de dialogue Pendant la phase d extinction il n est pas possible de remettre la chaudi re en marche tant que la temp rature des fum es n est pas descendue en dessous d une valeur pr d termin e
279. tire ring band without air gaps Brazier dirty Brazier clean Brazier holder clean 59 DOMUSFIRE C29 C35 C39 COLA 5 2 Cleaning the ash container The ash container is located directly under the brazier brazier holder To clean it open the ash door and remove the ash and any combustion residuals using a suitable vacuum cleaner The door must be closed after cleaning The ash container can be cleaned every 2 3 days depending on boiler use 5 3 Cleaning the fume extractor and combustion chamber The combustion chamber must be cleaned at least once a year removing all combustion residuals from the internal fume pipes and flueways To carry out this operation it is necessary to remove the boiler top cover the heating chamber cover and the bottom inspection door undoing the respective fixing screws then clean the turbulators and internal fume pipes Also make sure to clean the fume extractor located at the back of the bottom fume manifold accessed through the inspection door opening behind the ash box Every 3 4 months clean the inside walls of the combustion chamber and top fume manifold using suitable equipment brushes and replace the vermiculite walls if necessary Every 1800 hours of operation by means of a message SERVICE DUE the boiler signals the need for extraordinary maintenance not under warranty to be performed by qualified personnel who will carry out complete cleaning and reset the message A Any knocking
280. tizar la evacuaci n correcta de los humos 5 6 Limpieza de los intercambiadores con el sacudidor de turbuladores Los tubos de paso de humos situados dentro de la c mara t rmica se deben limpiar al menos una vez cada 2 3 d as accionando repetidamente los dos pomos hacia arriba y abajo A Realice esta operaci n con la caldera apagada y fria Al final controle que los pomos para sacudir los turbuladores est n bajados en reposo Pomos derecho e izquierdo del sacudidor de turbuladores en posici n baja funcionamiento de la caldera 155 DOMUSFIRE C29 C35 C39 6 MANTENIMIENTO 6 1 Introducci n COLA Las operaciones en los componentes internos de la caldera deben ser realizadas por personal del centro de asistencia autorizado Antes de cada operaci n compruebe que la clavija el ctrica est desconectada y la caldera est completamente fr a 6 2 Desmontaje del revestimiento de la caldera i 1 2 Y A 6 3 Componentes internos de la caldera 156 Leyenda 1 Tapa del dep sito de pellets 2 Tapas intermedias centrales 3 Panel lateral 4 Tapa frontal 5 Puerta exterior aislada 6 Panel posterior Leyenda 1 Pomo con varilla roscada 2 Eje del sacudidor de turbuladores 3 Tuerca de apriete del casquillo 4 Casquillo de paso del eje 5 Tapa exterior 6 Protecci n t rmica superior 7 Prot
281. to ERROR deben ser efectuadas por un centro de TRIACSINF de 60 segundos seguidos est averiado contactos asistencia autorizado El sistema se para pegados Se ala un fallo de la sonda AL que mide la T del agua La sonda esta averiada Las operaciones de restablecimiento SONDA visualizando T H20 0 C La sonda esta desconectada deben ser efectuadas por un centro de AGUA Se activa el procedimiento de de la tarjeta asistencia autorizado apagado AL d Sefiala que la temperatura La sonda de temperatura ALTA TMP del agua ha superado el l mite instalada en la c mara t rmica Localizar la causa del problema y establecido ha detectado un valor superior restablecer la temperatura correcta AGUA El sistema se para a 92 C Se presenta cuando la Intento de desbloqueo durante _ Eldesbisauso d l dans ESPERA caldera se enciende el apagado con la caldera osible Eo REFRIGER inmediatamente despu s de caliente y en fase de a ada haberla apagado enfriamiento pagado El control no detecta la FALLO Em cantidad de aire comburente Las operaciones de restablecimiento dabimelro esta pero no apaga la caldera sino deben ser efectuadas por un centro de DEBIMET desactiva solamente el asistencia autorizado debimetro El control da lacaldera La bomba se enciende para hacer PELIGRO Se ala que la temperatura circular agua en el circuito de HIELO del agua est
282. to de pellets 11 Conexi n serie 12 Transductor de presi n 6 5 Componentes hidr ulicos de serie Leyenda 1 Vaso de expansi n con membrana 2 Llave de descarga instalaci n 1 2 3 V lvula de seguridad de presi n 4 Tubo de ida con conexiones de 1 5 Circulador 6 Tubo de retorno con conexi n de 1 7 Transductor de presi n 8 Conexi n para carga instalaci n 12 9 V lvula de purga de aire sistema caldera 158 DOMUSFIRE C29 C35 C39 COLA 7 LOCALIZACION DE AVERIAS 7 1 Gestion de las alarmas La presencia de una alarma se indica con una sefal acustica si esta habilitada y un mensaje en el panel de control Si se produce una alarma apague la caldera solucione la causa que la ha provocado y encienda la caldera normalmente como se describe en el presente manual Todas las alarmas causan el apagado inmediato de la caldera A continuaci n se describen las alarmas que pueden aparecer en el panel de control con sus causas y soluciones ALARMAS MENSAJES Indicacion Anomalia Causas posibles Soluci n Poner la caldera en OFF con la tecla P4 y repetir el AL 1 i CORTE DE La caldera no se No hay alimentacion el ctrica dato enciende durante el encendido ora operacion LUZ restablecimiento debe ser efectuada por un centro de asistencia autorizado Indica un fallo de la sonda AL 2 de temperatura de los La so
283. todo si hay mucho pellet inquemado para garantizar una combusti n correcta puesto que el aire necesario para la combusti n entra por los orificios del brasero Controle tambi n que los orificios de los tubos laterales del portabrasero que distribuyen el aire secundario est n libres de residuos de la combusti n y de cenizas Cuando corresponda limpie el visor de vidrio de la puerta de la c mara que permite observar la llama El brasero se debe apoyar en el portabrasero ocupando todo el per metro y sin dejar aberturas por donde pueda pasar el aire Brasero sucio Brasero limpio Portabrasero limpio 5 2 Limpieza del cenicero El cenicero est debajo del brasero portabrasero Para limpiarlo abra la puerta respectiva y aspire las cenizas y los residuos de la combusti n con un aparato adecuado Una vez concluida la limpieza cierre la puerta El cenicero se puede limpiar cada 2 o 3 d as seg n el uso de la caldera 154 DOMUSFIRE C29 C35 C39 COLA 5 3 Limpieza del extractor de humos y de la c mara de combusti n Al menos una vez al a o se debe limpiar la c mara de combusti n eliminando los residuos de combusti n de los tubos de humos internos y del recorrido de los humos Para realizar esta operaci n quite la tapa superior de la caldera la tapa de la c mara t rmica y el registro inferior de inspecci n previa extracci n de los respectivos tornillos de fijaci n Limpie entonces los turbuladores y los tubos de humos
284. tor ducteur 3 Motor ducteur 4 Vis sans fin 5 Joint pour goulotte 6 Goulotte de granul s 7 Joint chambre convoyeur 8 Convoyeur granul s 94 DOMUSFIRE C29 C35 C39 6 4 Composants lectriques A E Y rn SA Pr l 6000006 95 y d COLA L gende 1 Panneau de commande mod EVO 2 Thermostats de s ret temp rature 3 Interrupteur ON OFF avec fusibles 4 Carte lectronique 5 Cordon d alimentation lectrique 6 Vacuostat 7 Transducteur de pression circuit hydraulique 7 Sonde des fum es 8 Sonde eau chambre de combustion 9 Sonde eau ballon puffer 10 Sonde de niveau sur r servoir granul s 11 Liaison s rie 12 Transducteur de pression L gende 1 Vase d expansion membrane 2 Robinet de vidange de l installation 12 3 Soupape de s ret 4 Tuyau d part avec raccords 1 5 Circulateur 6 Tuyau retour avec raccord 1 7 Transducteur de pression 8 Raccord de remplissage de l installation v2 9 Event chaudi re DOMUSFIRE C29 C35 C39 7 RECHERCHE DES PANNES 7 1 Gestion des alarmes Les alarmes sont signal es la fois visuellement l cran message et par un signal sonore si valid En cas d alarme teindre la chaudi re liminer la cause de la panne et remettre la chau
285. turbulateurs Avant d allumer la chaudi re s assurer que le d flecteur de flamme se trouve bien au dessus du brasier dans les fentes pr vues a cet effet Contr ler d autre part que le dispositif de secouage des turbulateurs se trouve au repos c est dire en position basse Un positionnement incorrect du brasier et ou des turbulateurs entra ne des anomalies de fonctionnement et une formation excessive de poussi res et d imbr l s A Lors de chaque allumage de l appareil contr ler la position correcte du brasier et du dispositif de secouage des turbulateurs 2 6 Branchement lectrique Brancher le c ble d alimentation lectrique d une part la prise arri re de la chaudi re et d autre part une prise lectrique murale La tension de l installation doit correspondre celle indiqu e sur la plaque d identification de la chaudi re et dans le paragraphe des donn es techniques de ce manuel Pendant la p riode d inutilisation de la chaudi re il est pr f rable de d brancher son c ble d alimentation conform ment aux normes en vigueur Le cordon d alimentation ne doit jamais entrer en contact avec le conduit d vacuation des fum es de la chaudi re i S assurer que l installation lectrique est quip e d une mise la terre et d un interrupteur diff rentiel 76 DOMUSFIRE C29 C35 C39 COLA 381311930 CODEUR FUM ES e Tz P N LLI 991 SINI LL
286. u circuit hydraulique laver fond les conduits du circuit pour liminer tout r sidu ou d chet des op rations d installation qui pourrait compromettre le fonctionnement des composants n cessaires au contr le au r glage et la s curit de l installation c dent en provoquant des fuites d eau pendant le fonctionnement il est donc conseill de contr ler le serrage des colliers des circulateurs et de la chambre de combustion pendant le remplissage d eau et apr s les premi res heures de service ainsi que de purger l air r siduel dans le circuit Pendant le transport il est possible que les joints et les colliers du syst me hydraulique se relachent ou 2 9 1 Remplissage eau Apr s avoir termin les raccordements hydrauliques proc der au REMPLISSAGE de l appareil et du circuit ouvrir tous les vents des radiateurs collecteurs chaudi re et circuit complet ouvrir progressivement le robinet de remplissage d eau en s assurant que les vents fonctionnent correctement remplir le circuit lentement pour assurer l vacuation correcte et compl te de l air en mettant le circuit sous pression de 1 1 1 5 bar pour un circuit vase ferm une fois l op ration termin e fermer le robinet de remplissage et s assurer que tous les vents aient vacu l air de la section correspondante A La r alisation d une installation de chauffage comprenant une chaudi re doit respecter toutes les normes nationales r
287. u dans l enceinte thermique et sur l installation Cet appareil n est pas concu pour tre utilis par des personnes y compris les enfants aux capacit s physiques sensorielles ou mentales r duites ou manquant d exp rience et ou de connaissance sans la surveillance d une personne responsable de leur s curit Surveiller les enfants et s assurer qu ils ne jouent pas avec les appareils ni dans le local o ils ont t install s Placer le cordon d alimentation lectrique et les fils des capteurs ext rieurs de sorte qu ils n entrent pas en contact avec les pi ces chaudes de la chaudi re ll est interdit de faire fonctionner l appareil si la porte du foyer et ou la porte du cendrier sont ouvertes Eviter de fermer ou de r duire les arriv es d air comburant et d vacuation des fum es La chaudi re ne doit pas tre utilis e comme incin rateur mais uniquement pour chauffer l eau de l installation de chauffage et ou d eau chaude sanitaire en utilisant comme seul combustible les granul s de bois dont les caract ristiques sont d crites dans le manuel Ne pas utiliser de liquides ou de substances inflammables pour allumer l appareil La chaudi re ne doit pas tre utilis e comme incin rateur ll est absolument interdit de manipuler des substances facilement inflammables ou explosives proximit de la chaudi re quand elle est allum e Eviter tout contact direct avec les parties de l appareil qui risquent de
288. uare la pulizia periodica del braciere ad ogni carico pellet alla prima accensione importante non surriscaldare la caldaia ma portarla gradatamente in temperatura impostando temperature di funzionamento basse vedere paragrafo impostazione temperatura la caldaia durante l accensione funzionamento e spegnimento a causa delle dilatazioni termiche a cui soggetta pu generare leggeri scricchiolii 4 2 Descrizione del pannello comandi Il pannello comandi amp costituito da un display LCD retroilluminato dal tasto di accensione spegnimento P4 dal tasto funzione SET MENU dai quattro tasti menu P1 P2 P5 P e da 7 led indicanti lo stato di funzionamento della caldaia Segnalatori di stato Display LCD retroilluminato Indicazioni display Pulsanti di impostazione e selezione Ricevitore IR Il pannello consente l accensione e lo spegnimento della caldaia la regolazione durante il funzionamento e permette il settaggio dei programmi di gestione e manutenzione Sul display sono visualizzate tutte le informazioni sullo stato di funzionamento della caldaia Per accedere ai menu procedere come segue premere il tasto SET premere i tasti P5 P6 per scorrere i vari menu premere su uno dei tasti di incremento decremeto P1 P2 per settare il parametro desiderato premere il tasto SET per confermare il valore del parametro
289. uate aux endroits pr vus a cet effet sur la palette en bois S assurer que les dispositifs de levage utilis s pour le transport sont en mesure de supporter le poids de la chaudi re indiqu sur la plaque d identification et dans ce manuel Eviter de passer dans des zones ou la chute de la charge pourrait repr senter un danger Durant le transport et le stockage viter d exposer l appareil la pluie ou l humidit persistante D placer la chaudi re uniquement la verticale l aide de chariots pos e sur sa base A Enlever les planches ou autres pi ces en bois faisant partie de l emballage de la chaudi re l aide de moyens appropri s L utilisateur est tenu liminer ou recycler l emballage en respectant les normes locales en vigueur en mati re de d chets et en vitant que les enfants ou des personnes handicap es ne puissent s en approcher 2 2 Lieu d installation mise en place et consignes de s curit anti incendie Apr s qu un technicien qualifi aura proc d au raccordement hydraulique et lectrique ouvrir l emballage d gager la chaudi re de la palette et la poser l endroit choisi pour son installation en v rifiant si tout est conforme aux indications fournies dans le manuel Il est recommand de poser d licatement la chaudi re au sol pour viter tout choc ventuel et de l installer dans la zone pr vue s assurer galement que le plancher est assez solide pour supporter le poids de la cha
290. udi re dans le cas contraire consulter un technicien sp cialis Apr s avoir t l emballage de protection viter tout choc ou jet d eau pour ne pas endommager les parties m caniques et lectriques La pi ce dans laquelle la chaudi re est install e doit tre suffisamment a r e pour assurer une bonne vacuation en cas de fuite ventuelle de fum e de combustion L appareil peut fonctionner dans un local technique ayant une temp rature minimum de 0 il dispose d une fonction antigel qui amorce la pompe de chauffage d s que la temp rature de l eau du circuit descend en dessous de 6 C afin de prot ger la chambre de combustion et le circuit de chauffage sanitaire La fonction antigel est disponible uniquement sur les chaudi res alimentation lectrique Installer la chaudi re une distance convenable par rapport des mat riaux inflammables ou combustibles et pr voir des parois tanches l air ou des syst mes isolants appropri s prot ger les sols et ou les plafonds ou parois en mati res inflammables ou sensibles la chaleur l aide de panneaux de protection en mat riau isolant S assurer que le local technique renfermant la chaudi re dispose d un espace suffisant pour la maintenance et le nettoyage des appareils des conduits et des carneaux des fum es aussi bien sur les c t s qu l arri re S assurer galement que l on acc de facilement au r servoir granul s pour le remplir Les distanc
291. uelle Bearbeitungsr ckst nde zu beseitigen die den ordnungsgem en Betrieb der Kontroll Einstellungs und Sicherheitsvorrichtungen der Anlage beeintr chtigen k nnten nachgeben sodass sp ter w hrend des Betriebs Wasser austritt Deshalb sollten die Anschl sse der Pumpen und der Heizkammer sowohl beim Bef llen als auch nach den ersten Betriebsstunden kontrolliert und die in der Anlage gebliebene Restluft abgelassen werden W hrend des Transports des Kessels k nnen sich die Dichtungen des Wasserkreises lockern und oder 2 9 1 Bef llen der Anlage mit Wasser Nach Durchf hrung der Wasseranschl sse kann das Ger t und die entsprechende Anlage GEF LLT werden Alle Entl ftungsventile der Heizk rper Sammelleitungen Kessel und Anlage ffnen Den Wasser Einf llhahn allm hlich ffnen und pr fen ob die Entl ftungsventile ordnungsgemaB funktionieren Das Wasser langsam in die Anlage einf llen um ein korrektes und vollstandiges Entl ften zu gestatten dazu den Kreislauf mit Druck beaufschalgen f r eine Anlage mit geschlossenem Ausdehnungsgef B zwischen 1 1 und 1 5 bar Am Ende des Vorgangs den Einf llnahn schlieBen und sicherstellen dass alle Entl ftungsventile die Luft abgelassen haben Die Ausf hrung einer Heizungsanlage mit Installation des Heizkessels sind die im Installationsland geltenden Bestimmungen auf nationaler regionaler und kommunaler Ebene zu erf llen 2 9 2 Eigenschaften des Anlagenwassers Die ch
292. unghe inattivit dell apparecchio richiedono il ripristino di eventuali residui di pellet giacenti da tempo all interno del serbatoio in quanto combustibile umido non pi idoneo alla combustione e una pulizia completa della camera di combustione Alla prima messa in funzione togliere dal focolare della caldaia tutti i componenti che potrebbero 4 3 2 Fase di avvio Per accendere la caldaia premere il pulsante P4 per 3 secondi sul display comparir la scritta START Questa fase automatica ed completamente gestita da controllo elettronico senza alcuna possibilit di intervenire sui parametri In alternativa possibile accendere la caldaia premendo contemporaneamente il pulsante P4 e P5 per 3 secondi Sul display compare la scritta ATTESA RICHIESTA Con questa modalit la caldaia si pone in uno stato di attesa ed esegue la fase di accensione start solo se viene riconosciuta una richiesta di calore ad esempio per riscaldare l acqua o per l acqua calda sanitaria se disponibile Temperatura H20 Boiler Puffer Pulsante P4 Temperatura acqua La caldaia esegue in sequenza le fasi di avvio secondo le modalit definite dai parametri che ne gestiscono livelli e tempistica raggiungendo la condizione di lavoro a meno che non insorgono anomalie o allarmi secondo il prospetto seguente dispositivi condizioni per passaggio a stato successivo scamb START PRERISC decorso tempo 40 PRECARI
293. utwards To open the door fit the handle supplied and turn it clockwise Fire and ash box door opening closing handle Opening anticlockwise Closing clockwise 1 5 Permissible use and fuel The pellet boilers work exclusively on pellets in various types of wood complying with Standard DIN plus 51731 or UNI EN 14961 2 or O Norm M 7135 or having the following characteristics Heat value min 4 8 kWh kg 4180 kcal kg Density 680 720 kg m3 Moisture max 10 weight Diameter 6 0 5 mm Ash percentage max 1 5 weight Length min 6 mm max 30 mm Composition 100 untreated wood from the wood industry or post consumer without added binding substances or bark complying with the current regulations Packing in bags made from environmentally friendly or biodegradable material or paper The pellet hopper is at the back of the boiler The door is located in the top part and loading occurs manually only with the boiler off making sure not to overfill The use of pellets with characteristics different from those tested by the technician during first lighting involves a new setting of the boiler pellet loading parameters this operation is not covered by the warranty Store the pellets in a dry place For reasons of regular and efficient operation pellets or other fuels cannot be manually loaded in the N brazier Over time the pellet hopper accumulates dust which could compromise proper feeding therefore it is advisable t
294. valves have discharged the air from the system The creation of a heating system with installation of the boiler must comply with all the applicable A National Regional Provincial and Local regulations in the country where the system is installed 2 9 2 System water characteristics The chemical physical characteristics of the system and replenishing water are important for the proper operation and service life of the boiler in fact with the use of low quality water the most frequent problem is due to scale which causes a reduction in heat exchange and generates corrosion It is therefore advisable to check the water quality and in the conditions listed below provide for treatment very hard water 20 f considerable amounts of replenishing water or subsequent fillings systems of some complexity and size 2 9 3 DHW system To connect the boiler to a DHW system it is advisable to see a qualified technician in order to best optimise the plumbing connections and the performance of the entire system without compromising unit functionality One of the following optionals must be requested for the connection to the DHW circuit a DHW pump on the delivery manifold with respective connection pipes for placing inside the boiler or a DHW pump plate heat exchanger and connection pipes for placing inside the boiler or a 3 way valve for installing outside the boiler 47 DOMUSFIRE C29 C35 C39 COLA After completing the DHW co
295. very in order to reduce the amount to be sent for disposal and improving the operation of parties participating in the life cycle of these products The barred waste bin symbol on the label indicates that at the end of its service life the unit must be collected separately from other household waste 1 10 Instructions for requesting assistance and replacement parts To request any assistance and or replacement parts contact the dealer area importer or the nearest authorised service centre clearly specifying the following boiler model serial number date of purchase list of replacement parts details of faults or malfunctioning Make sure all electrical connections are disconnected and that the boiler is cold before any work on it Only use original replacement parts 1 All operations on components must be carried out by authorised and or qualified personnel 42 DOMUSFIRE C29 C35 C39 COLA 2 TRANSPORT AND INSTALLATION 2 1 Conditions of supply transport and storage The boiler is delivered wrapped in nylon protection and packed on a pallet wooden crate after completing the production cycle and the functional testing on the assembly line at the manufacturer s factory The unit complete with packing can be lifted using a lift truck inserting the forks of suitable length in the special spaces in the wooden pallet Make sure the equipment used for lifting and transport can take the boiler s weight specified on the data plate and
296. vole di zona ed il conseguente blocco del flusso di mandata dell acqua calda 2 9 Collegamenti idraulici La potenzialit termica dell apparecchio va stabilita preliminarmente con un calcolo del fabbisogno di calore dell edificio secondo le norme vigenti e rivolgendosi ad un tecnico specializzato Secondo la norma italiana UNI 10412 2 2009 e la buona tecnica d installazione un impianto di riscaldamento deve essere corredato di tutti i componenti di regolazione controllo e sicurezza atti a garantire un regolare funzionamento in sicurezza nonch valvole d intercettazione e di non ritorno che permettano d isolare la caldaia dall impianto in caso di manutenzioni e o controlli Esistono due tipologie d impianto impianto a VASO CHIUSO e impianto a VASO APERTO nel ns caso entrambi le tipologie sono compatibili con il ns apparecchio purch vengano installati tutti i componenti di regolazione controllo e sicurezza previsti dalle Norme vigente in materia d installazione La caldaia a pellets presenta al suo interno il circuito idraulico di riscaldamento e precisamente circolatore valvola di sicurezza sfiato aria sonde di temperatura e trasduttore di pressione Si rende noto che qualora l impianto di riscaldamento sia gestito a zone indispensabile introdurre una centralina multizona disponibile su richiesta Nelle caldaie a combustibile solido per evitare durante la fase di riscaldamento il ritorno di acqua fredda nella termo camera
Download Pdf Manuals