1. nn 24 Installation dans la ma onnerie een 25 Garantie Danfoss ss No bon oo 27 Copyright 2009 Danfoss Inc 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 1 Danfoss GX Snow Melting System Copyright 2009 Danfoss Inc Danfoss GX Snow Melting System The GX Snow Melting System consists of the GX 850 Automatic Control Panel ACP heating cables or heating mats and multiple digitally operated sensors which provide an economical and efficient means of snow melting and ice protection Built for outdoor use the GX system provides safety and peace of mind to homeowners and business owners alike Engineered for surfaces such as asphalt concrete and paving tiles the Danfoss GX Snow Melting System is both versatile and easy to install The Danfoss GX Snow Melting System operates automatically by digitally sensing moisture and temperature The GX System is embedded during the paving installation such that some control and accessories must also be installed at this time It is recommended to install thermal insulation below the application of the heating cables or mats Improved performance and efficiency will decrease overall operating costs CAUTION It is important that this equipment is only installed by qualified electricians who are familiar with the proper sizing installation construction and operation of outdoor heating systems and the hazards involved The GX system is designed for outdoor ice and snow melting appl
2. r alis e date de l installation 3 Si l installation a d j t r alis e nom de l lectricien et du poseur de rev tement de sol 4 Relev s de r sistance effectu s par l installateur 5 Preuve d achat et num ro de s rie mentionn sur l tiquette du produit Notre service apr s vente fournit alors un num ro d autorisation et informe des tapes suivre pour la r clamation de garantie Exclusion de garantie Cette garantie conc de des droits l gaux sp cifiques et certains droits peuvent galement varier d un tat un autre Danfoss d cline par la pr sente toute responsabilit a titre de condition de vente quant l absence de garanties implicites Certains tats n autorisent pas de limites sur une garantie implicite par cons quent la limite susmentionn e peut ne pas s appliquer Fabricant Adresse Danfoss Inc 6711 Mississauga Rd Suite 410 Toronto ON L5N 2W3 T l phone 905 285 2050 866 676 8062 T l c 905 285 2055 Tous droits r serv s 2009 Danfoss Inc 088L3370 06 09 T l 1 866 676 8062 T l c 905 285 2055 27
3. 1 866 676 8062 T l c 905 285 2055 18 Installation d un c ble d alimentation Pour utilisation avec le Gx850 et ou des d tecteurs au sol ne peut s appliquer au DS 2B Il pourrait s av rer n cessaire d utiliser un c ble d alimentation pour d tecteur Un c ble de 15 m 50 pi est fourni avec chaque d tecteur Il faut enrouler environ 0 5 m 1 5 pi de ce c ble dans la partie inf rieure du tube du d tecteur Le reste du c ble peut tre allong Le c ble d alimentation doit tre un c ble quatre fils Installation de d tecteur et du conduit On peut installer le d tecteur et le conduit en association avec les travaux de construction et les brancher une date ult rieure Les dispositions suivantes s appliquent tout type d installation 1 2 Assurez vous que le conduit est scell au moment du versement du b ton Le conduit doit tre plac de sorte tre galit avec le terrain voisinant Le d tecteur doit tre plac de fa on mettre l horizontale la surface sup rieure en laiton La base sous le tube doit tre dure carreau en b ton de fa on s assurer que le d tecteur n est pas enfonc dans le sol lors du passage d une voiture par exemple Ce tube est con u pour tre mont sur une plaque gr ce aux deux trous vis l int rieur du conduit Un tuyau en m tal ou en plastique par lequel passe le c ble du d tecteur doit aller aussi loin que le conduit du d tecteur
4. Enroulez environ 0 5 m 1 5 pi du c ble du d tecteur dans le conduit Placez le d tecteur l int rieur du tube jusqu ce qu il soit galit l horizontale avec le bord du conduit et qu il repose sur le col interne l int rieur du conduit Le Installation de conduit avec c ble de d tecteur Installation dans l asphalte Tous droits r serv s 2009 Danfoss Inc La temp rature autour du d tecteur tube ne doit pas d passer 80 C 176 F Vous pouvez mettre un bloc de bois ou un autre dispositif semblable la o le tuyau ou d tecteur sera plac par la suite Le tuyau d installation utilis pour le c ble de d tecteur doit alors tre fait de m tal pouvant supporter les temp ratures lev es 088L3370 06 09 T l 1 866 676 8062 T l c 905 285 2055 19 Placement du d tecteur au sol ll est important de placer les d tecteurs correctement en vue d un fonctionnement appropri Certaines lignes directrices de base sont d crites ci dessous Nombre de d tecteurs au sol 1 Plus il ya de d tecteurs mieux sera le rendement 2 Le principe de base consiste placer un d tecteur l o la neige ou la glace appara tra en premier pour permettre une d tection rapide et un d tecteur o la neige ou la glace dispara tra en dernier pour permettre une fonte compl te Si cela s av re difficile tablir placez les d tecteurs aussi loin l un de l autre que possible 3 Si vous n
5. Installation Manual Danfoss GX Heating Cables amp Mats Manuel d installation C bles et tapis de chauffage Danfoss GX Danfoss ED BRINGING WARMTH TO LIFE Table of Contents Danfoss GX SHOW Melting System a iacsehnccnssistireanselnannhnanaisaconuanannuanaguumunnots 2 Danfoss GX Cable Mat isccscsssciscssscsssaieacesstscecussodsecaussauconsstensstsesindeac dest dcssassedussessenascoasesrdecbissits 3 Warning Sescscssiscesctassdsasedstasecevvesvassbaseindassecudcusssnrnsansehconesteivusuesdascatosasstusesstebsniansadseousedoswsanceussbeosess 4 General Installation Guidelines sn 5 Sensor Installations nsssnsnsmennarennneentenesehnenenenntnntienss e 6 S nisor Placement sarisini a E a A AEA Aias 7 Installing the Heating Mat Cables smart 8 Concrete INstallatiOM crececcsccscsssscsancssvescssesccdecssssssscseuaseucssnseluctaneddtsebesscesdecsssicavsbenesbnctsbiscacterdie 9 Asphalt Installation sanciccsssdssesectn castes adaateasaateciies datate eattecaetaadiacdalesaiasechgeeieeieat dite 11 Stonework Installation 12 DA OSS WatfaNty aan ne en a nantes 14 Table des Mati res Fondeuse neige Danfoss Garmin sstiamnantnmntanniennnee 15 Cable tapis Dao GX adidas 16 Mises en darde una NE Me te dan 17 Lignes directrices g n rales d installation 18 Installation du d tecteur 19 Placement du d tecteur 20 Installation du tapis c ble de chauffage 21 Installation dans le b ton 22 Installation dans l asphalte
6. 347 480 600V Output 50W sq ft 540W m Cable 12W ft Heating Element Size Mat 6 5 1 98 m 80 24 38 m long x 2 0 61 m wide Cable 35 545 10 7 166 m Power Lead 20 6 0 m Bending Radius Minimum 1 5 3 8 cm Cable Diameter 1 4 0 65 cm Conductor Insulation FEP Teflon Outer Insulation PVC Max Temperature 220 F 105 C Min Installation Temp 40 F 5 C Connection all voltages Phase Black Phase White Ground Green Copyright 2009 Danfoss Inc 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 Warnings Copyright 2009 Danfoss Inc Caution Is it important to read the instructions carefully before installing the Danfoss GX Snow Melting System For outdoor installation only Never cut the black heating cable Extreme care must be used to ensure the GX cables are not damaged when using sharp tools wheelbarrows heavy machinery and paving equipment shovels rakes or other implements Avoid walking on the cables or mats during installation It is not recommended to install the Danfoss GX heating mats with a controller that does not contain an integrated temperature limiter The GX mat or GX cable must be embedded in mortar or mortar mixture concrete sand or similar material The power lead heating cable connection and at least 1 30 cm of the power lead must be embedded in the paved surface Remaining power lead should be run through the conduit
7. de votre installation Ne la d passez pas Si vous avez des questions ou des inqui tudes communiquez avec votre d positaire Danfoss GX local e Assurez vous que le c ble n est pas soumis une tension ou une pression excessive Il ne doit pas croiser de joint de dilatation e Le c ble de chauffage doit tre mis la terre conform ment aux codes lectriques locaux Assurez vous de d poser le c ble et non de le pousser dans le mat riau d isolation e Assurez vous qu il n y a aucune pochette d air dans le mat riau de surface car cela pourrait endommager le c ble e Il faut installer un d branchement en amont pour assurer une fa on de mettre hors tension le c ble ou le tapis basse temp rature le c ble de chauffage se raidit et il peut devenir difficile de le travailler Pour viter ce probl me branchez le c ble au secteur pendant une br ve p riode Assurez vous que le c ble est compl tement d roul pour ce faire 088L3370 06 09 T l 1 866 676 8062 T l c 905 285 2055 24 Installation dans l asphalte suite e cll est recommand de couvrir les c bles d une couche de sable ou de b ton d au moins 2 5 cm 1 po d paisseur avant l asphalte afin de les prot ger de la chaleur de l asphalte Lutilisation de sable ou de b ton assurera un transfert de chaleur efficace a travers l asphalte Laissez la temp rature de l asphalte descendre jusqu 130 140 C 265 285 F avant de la
8. l installation des c bles de chauffage il faut respecter les directives suivantes Commencez l installation aussi pr s que possible de la source d alimentation lectrique Le c ble de chauffage ne doit pas tre coup raccourci ni expos une tension au niveau du raccord de c ble de chauffage et du bout froid Installez les c bles dans une direction perpendiculaire la direction des rouleaux de pavage afin d viter de mettre de la pression sur les c bles ou de les endommager Mettez de l isolation p ex de la perlite volcanique sous les c bles et sur les c t s de la surface chauff e pour am liorer l efficacit du syst me de chauffage e Voyezla page 7 pour le placement des d tecteurs e Il faut faire particuli rement attention de ne pas endommager les cables de chauffage avec des outils et de la machinerie pendant l installation et la pose du mat riau de surface e Assurez vous d enlever les pierres et les d bris tranchants de l endroit o l on pr voit installer les c bles de chauffage Si le cable est endommag pendant le processus d installation il est utile de conna tre l emplacement du raccord entre le c ble de chauffage et le bout froid Prenez une photo ou faites un dessin pour savoir o s effectue le raccord et o se trouve l embout en cas de d fectuosit e Le raccord du c ble de chauffage doit tre effectu par un lectricien autoris Prenez note de la sortie maximale
9. liorer l efficacit du syst me de chauffage Voyez la page 7 pour le placement des d tecteurs e Le b ton ne doit pas contenir d agglom rat de plus de po e Il faut faire particuli rement attention de ne pas endommager les c bles de chauffage avec des outils et de la machinerie pendant l installation et la pose du mat riau de surface e Assurez vous d enlever les pierres et les d bris tranchants de l endroit o l on pr voit installer les c bles de chauffage e Sile c ble est endommag pendant le processus d installation il est utile de conna tre l emplacement du raccord entre le c ble de chauffage et le bout froid Prenez une photo ou faites un dessin pour savoir o s effectue le raccord et o se trouve l embout en cas de d fectuosit Le raccord du c ble de chauffage doit tre effectu par un lectricien autoris e Prenez note de la sortie maximale de votre installation Ne la d passez pas Si vous avez des questions ou des inqui tudes communiquez avec votre d positaire Danfoss GX local e Assurez vous que le cable n est pas soumis une tension ou une pression excessive Il ne doit pas croiser de joint de dilatation S il y a des joints de dilatation prenez un autre tapis ou un autre cable e Le c ble de chauffage doit tre mis la terre conform ment aux codes lectriques locaux Assurez vous de d poser le c ble et non de le pousser dans le mat riau d isolation e Assurez vous qu il
10. m tallique au moyen des attaches tiquettes Placez les tiquettes 2E ou F sur le tableau de contr le Les tiquettes 3E et F doivent tre plac es dans la pi ce ou dans le lieu o on installe le tapis ou c ble de chauffage Distance de centre centre Tous droits r serv s 2009 Danfoss Inc La distance de centre centre est la distance entre les c bles GX les tapis GX ont une distance centre centre pr tablie L espace standard pour 540 W m 50 W pi ca est de 7 5 cm 3 po Dans une application type la distance de centre centre ne doit pas d passer 4 po et doit tre inf rieure 3 po si les c bles sont install s l int rieur d un syst me de chauffage total Si la distance de centre centre est sup rieure on pourrait voir appara tre des endroits froids la surface et une fonte incompl te 088L3370 06 09 T l 1 866 676 8062 T l c 905 285 2055 Installation dans le b ton Tous droits r serv s 2009 Danfoss Inc Lors de l installation des cables de chauffage Danfoss GX il faut respecter les directives suivantes Commencez l installation aussi pr s que possible de la source d alimentation lectrique Le c ble de chauffage ne doit pas tre coup raccourci ni expos une tension au niveau du raccord de c ble de chauffage et du bout froid Mettez de l isolation p ex de la perlite volcanique sous les c bles et sur les c t s de la surface chauff e pour am
11. the location of the cold tail heating cable connection Take a picture or sketch to show where the connection end cap is in case a fault needs to be found Connection of the heating cable must be carried out by an authorized electrician Note the maximum output allowed for your installation Do not exceed it Contact your local Danfoss GX dealer for questions concerns Make sure the cable is not subjected to excess tension or strain It should not cross an expansion joint Where expansion joints are present separate mats cables should be used The heating cable braid must be grounded in accordance with local electrical codes Make sure when the cable is laid it is not pushed into the insulating material Ensure no air pockets exist in the surface material as this can result in damage to the cable and limit the heat transfer An upstream disconnect must be installed to ensure a means of de energizing the cable or mat At low temperatures the heating cable stiffens and may be difficult to work with To overcome this connect the cable to the mains for a brief period of time Ensure the cable is fully rolled out when this is done 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 9 Concrete Installation continued e The cables are normally covered by 2 inches of concrete A thicker surface may be required depending on the pour and application Make sure that the free cable is fastened at intervals of minimum 3 45 cm a
12. verser sur les tapis ou c bles Les tubes ou d tecteurs au sol ne devraient pas tre expos s une temp rature d passant 176 C 80 F e L asphalte doit tre paisse d au moins 3 2 cm 1 25 po TAPIS FIX DANS a ASPHALTE SABLE BETON TAPIS DE CHAUFFAGE GX SABLE BETON ENCASTRE PIERRES CONCASS ES ET OU ISOLATION SOL TAPIS FIX DIRECTEMENT p ASPHALTE DANS L ASPHALTE LS GX LE TAPIS CABLE CHAUFFANT DANS L ASPHALTE PERMETTEZ L ASPHALTE DE VOUS REFROIDIR 220 F AVANT LE FAIT DE VERSER SUR LES TAPIS C BLES PIERRES CONCASS ES ET OU ISOLATION SOL Installation dans la ma onnerie Tous droits r serv s 2009 Danfoss Inc Lors de l installation des c bles de chauffage il faut respecter les directives suivantes e Commencez l installation aussi pr s que possible de la source d alimentation lectrique Le c ble de chauffage ne doit pas tre coup raccourci ni expos une tension au niveau du raccord de c ble de chauffage et du bout froid e Mettez de l isolation p ex de la perlite volcanique sous les c bles et sur les c t s de la surface chauff e pour am liorer l efficacit du syst me de chauffage e Voyezla page 7 pour le placement des d tecteurs e faut faire particuli rement attention de ne pas endommager les cables de chauffage avec des outils et de la machinerie pendant l installation et la pose du mat riau de surface
13. Danfoss GX doivent tre mis la terre conform ment la norme C22 1 article 10 de la CSA et au Code national de l lectricit 088L3370 06 09 T l 1 866 676 8062 T l c 905 285 2055 17 Lignes directrices g n rales d installation Tous droits r serv s 2009 Danfoss Inc Planification Il est recommand de tracer un plan de l installation du syst me de chauffage Prenez en note l emplacement du tapis ou des c bles du d tecteur des bo tes de connexion des conduits des drains et des obstructions Modifications des tapis Les tapis de chauffage GX peuvent tre modifi s pour s adapter aux drains aux obstructions et aux courbes du plan d implantation On peut cr er un grand nombre de dessins et motifs en d coupant soigneusement le ruban du tapis Voyez les illustrations ci dessous Comment couper Virage en U Virage en ventail le rouleau Coupez et tournez l Changement de direction Coupez le treillis LS et tournez H Ss a ad Etape de virage en U tape de virage en U tape de virage en U Avant Avant Extending th cols bad by usng hazdngvane i seen Bout froid Fil de chauffage ete rene ee eee Ey QT PT DUR PTS C ble gratuit et fixation des c bles avec courroies Si vous fixez le c ble GX avec une courroie Danfoss suivez les instructions ci dessous qui facilitent l installation 088L3370 06 09 T l
14. The power lead may be extended if required Do not install the Danfoss GX cables in such a manner that two black heating cables touch cross or overlap Remember to always measure verify and record the actual resistance throughout the installation process 1 Out of the box 2 After installation 3 Before pouring the sand concrete asphalt 4 After surface material application Record these values in the table on page 20 and on the warranty card failure to do so will void the warranty Measure the resistance between two live conductors as well as the resistance between each conductor and the ground wire Danfoss recommends using a megaohmmeter to test the insulation resistance Remember to check that the supply voltage matches the voltage required for your particular Danfoss GX product Remember to place the labels as instructed in this manual Metal structures or materials used for the support of or on which the Danfoss GX is installed must be grounded in accordance with CSA Standard C22 1 Section 10 and the NEC Please consult the Danfoss Electrical Heating Division for any other questions concerns or advice 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 4 General Installation Guidelines Planning It is recommended to sketch a plan of the layout for the heating system installation Mat cable location sensor placement junction boxes conduits and the location of drains and other obstructions should be
15. ables with tools and machinery during the installation and application of the surface material Ensure that all sharp stones and debris are removed from the area where the heating cables are going to be installed Should the cable become damaged during the installation process it is helpful to know the location of the cold tail heating cable connection Take a picture or sketch to show where the connection end cap is in case a fault needs to be found 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 12 Stonework Installation continued Copyright 2009 Danfoss Inc Connection of the heating cable must be carried out by an authorized electrician Note the maximum output allowed for your installation Do not exceed it Contact your local Danfoss GX dealer for questions concerns Make sure the cable is not subjected to excess tension or strain It should not cross an expansion joint The heating cable braid must be grounded in accordance with local electrical codes Make sure when the cable is laid that it is not pushed into the insulating material Ensure no air pockets exist in the surface material as this can result in damage to the cable and limit the heat transfer An upstream disconnect must be installed to ensure a means of de energizing the cable or mat Atlow temperatures the heating cable stiffens and may be difficult to work with To overcome this connect the cable to the mains for a br
16. ant r siduel pour l ext rieur Tous droits r serv s 2009 Danfoss Inc 088L3370 06 09 T l 1 866 676 8062 T l c 905 285 2055 15 C ble tapis Danfoss GX Tous droits r serv s 2009 Danfoss Inc Les c bles de fonte de neige Danfoss GX sont la base de cette fondeuse neige lectrique con ue pour faciliter le processus d enl vement de neige et de r duire son impact sur l environnement L appareil GX est la fois efficace et conomique Il consiste en des cables de chauffage conducteurs doubles et pr sente un seul point de connexion avec fil lectrique de 6 m 20 pi Les c bles Danfoss sont homologu s CSA e C bles tapis de fonte de neige pouvant tre utilis s avec du b ton de l asphalte des pav s et la ma onnerie si la temp rature de l asphalte d passe 105 C 220 F il faut ins rer les c bles dans du sable e Id al pour les entr es les terrains de stationnement les trottoirs les escaliers les rampes les aires de chargement et les ponts e R duit l impact sur l environnement de l enl vement de la neige et de la glace en liminant l utilisation des souffleuses des charrues neige qui utilisent un combustible fossile et l utilisation de sel blanc et ou d autres produits chimiques e Fonctionnement sur silencieux efficace et automatique e Point de connexion unique e Champ lectromagn tique nul Sp cifications des cables et tapis Danfoss GX Type Conducteur doubl
17. e Tension 208 240 277 347 480 600V Sortie 540 W m 50 W pi ca c ble 120W pi Dimensions des l ments 1 98 m 6 5 pi 24 38 m 80 pi de longueur x 0 61 m de chauffage Tapis 2 pi de largeur Cable 10 7 m 166 m 35 pi 545 pi Fil de courant 6 m 20 pi Rayon de la courbure Minimum 3 8 cm 1 5 pi Diam tre des c bles 0 65 cm 4 po Isolation des conducteurs T flon FEP Isolation ext rieure PVC Temp rature max 105 C 220 F Temp d installation min 5 C 40 F 088L3370 06 09 Connexions toutes tensions Phase Noire Phase Blanche Terre Verte T l 1 866 676 8062 T l c 905 285 2055 16 Mises en garde Tous droits r serv s 2009 Danfoss Inc Attention Il est important de lire les instructions avec soin avant d installer la fondeuse neige Danfoss GX Ce dispositif a t con u en vue d une installation l ext rieur seulement e Ne coupez jamais le c ble de chauffage noir e lfaut faire tr s attention de ne pas endommager les c bles du GX avec les outils tranchants les brouettes la machinerie lourde l quipement de pavement les pelles les r teaux et les autres accessoires vitez de marcher sur les c bles ou tapis pendant l installation e l n est pas recommand d installer les tapis de chauffage Danfoss GX avec une commande ne comportant pas un dispositif int gr de
18. e Assurez vous d enlever les pierres et les d bris tranchants de l endroit o l on pr voit installer les c bles de chauffage e Sile c ble est endommag pendant le processus d installation il est utile de conna tre l emplacement du raccord entre le c ble de chauffage et le bout froid Prenez une photo ou faites un dessin pour savoir o s effectue le raccord et o se trouve l embout en cas de d fectuosit 088L3370 06 09 T l 1 866 676 8062 T l c 905 285 2055 25 Installation dans la ma onnerie suite Le raccord du c ble de chauffage doit tre effectu par un lectricien autoris e Prenez note de la sortie maximale de votre installation Ne la d passez pas Si vous avez des questions ou des inqui tudes communiquez avec votre d positaire Danfoss GX local e Assurez vous que le c ble n est pas soumis une tension ou une pression excessive Il ne doit pas croiser de joint de dilatation Le c ble de chauffage doit tre mis la terre conform ment aux codes lectriques locaux Assurez vous de d poser le c ble et non de le pousser dans le mat riau d isolation Assurez vous qu il n y a aucune pochette d air dans le mat riau de surface car cela pourrait endommager le c ble Il faut faire particuli rement attention de ne pas endommager les c bles de chauffage s ils sont sous des briques ou des pav s L endroit doit tre compl tement niveau et d pourvu de pierres et d autres obj
19. e a picture or sketch to show where the connection end cap is in case a fault needs to be found Connection of the heating cable must be carried out by an authorized electrician Note the maximum output allowed for your installation Do not exceed it Contact your local Danfoss GX dealer for questions concerns Make sure the cable is not subjected to excess tension or strain It should not cross an expansion joint The heating cable braid must be grounded in accordance with local electrical codes Make sure when the cable is laid it is not pushed into the insulating material Ensure no air pockets exist in the surface material as this can result in damage to the cable and limit the heat transfer An upstream disconnect must be installed to ensure a means of de energizing the cable or mat Atlow temperatures the heating cable stiffens and may be difficult to work with To overcome this connect the cable to the mains for a brief period of time Ensure thecable is fully rolled out when this is done Copyright 2009 Danfoss Inc 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 11 Asphalt Installation continued It is recommended to cover the cables with a layer of sand or concrete at least 1 2 5 cm before the asphalt is applied to protect them from the heat of the asphalt Use of sand or concrete will ensure an effective and efficient heat transfer through the asphalt If using sand or concrete allow the aspha
20. ets tranchants Le c ble de chauffage doit tre install pr s des briques ou pav s habituellement dans une couche de sable au moins 2 5 cm 1 po sous les briques MACONNERIE TAPIS DE CHAUFFAGE GX ee 0 000 o4 DANSLESABLE SABLE PIERRES CONCASS ES ET OU ISOLATION SOL Tous droits r serv s 2009 Danfoss Inc 088L3370 06 09 T l 1 866 676 8062 T l c 905 285 2055 26 GARANTIE PROLONG E LA GARANTIE D CRITE AUX DISPOSITIONS PR C DENTES TIENT LIEU DE TOUTE AUTRE GARANTIE EXPLICITE OU IMPLICITE DE LA PART DE DANFOSS DANFOSS RENONCE A TOUTE GARANTIE EXPLICITE OU IMPLICITE QUANT LA QUALIT MARCHANDE OU L ADAPTATION DU PR SENT DISPOSITIF UN USAGE PARTICULIER DANFOSS N ASSUME AUCUNE RESPONSABILIT NI N AUTORISE AUCUNE PERSONNE ENTREPRISE OU SOCI T A ASSUMER AUCUNE RESPONSABILIT EN SON NOM EN RELATION LA VENTE OU AU PRODUIT DANFOSS NE SERA PAS TENUE RESPONSABLE DES DOMMAGES SUBIS PAR UNE PERSONNE OU TOUCHANT UN BIEN PERTES INDIRECTES PERTES DE B N FICES PERTES RELATIVES LA MARCHANDISE D UN MAGASIN OU AUTRES PERTES SEMBLABLES POUVANT D COULER D UN NON FONCTIONNEMENT DE L QUIPEMENT LIVR PEU IMPORTE LA CAUSE Y COMPRIS UN D FAUT DE FABRICATION R clamation de garantie Contacter le service apr s vente de la soci t et fournir les informations suivantes 1 Nature du d faut de fabrication 2 Date d achat et si l installation a d j t
21. he manufacturing defect Date of purchase and if already installed date ofinstallation If installed name of electrician and flooring installer Resistance readings taken by installer Proof of purchase and serial number from product label Our Customer Service department will provide you with an authorization number and advise you on the next steps to complete your warranty claim Copyright 2009 Danfoss Inc 088L3370 06 09 Disclaimer This warranty gives you specific legal rights and you may also have some legal rights which may vary from state to state or province to province Danfoss hereby disclaims and it is as a condition of the sale that there are no implied warranties Some states and provinces do not allow limitations on an implied warranty so the above limitation may not apply to you Manufacturer Mail Danfoss Inc 6711 Mississauga Rd Suite 410 Toronto ON L5N 2W3 Phone 905 285 2050 1 866 676 8062 Fax 905 285 2055 TEL 866 676 8062 FAX 905 285 2055 14 Fondeuse neige Danfoss GX Fondeuse neige Danfoss GX La fondeuse neige GX consiste en un panneau de commande automatique GX 850 des c bles ou tapis de chauffage et des d tecteurs multiples fonctionnement num rique qui fournissent une fa on conomique et efficace de faire fondre la neige et une protection contre la glace B tie en vue d une utilisation l ext rieur la fondeuse neige GX procure s curit et tranquillit d e
22. ications only Note The installation shall be in accordance with the manufacturer s instructions and national and local electrical codes The installation shall be in accordance with Part 426 American National Standard Institute National Fire Protection Association ANSI NFPA70 National Electrical Code NEC and Canadian Electrical Code CEC Part 1 You must use a ground fault equipment protection GFEP device for outdoor areas 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 2 Danfoss GX Cable Mat Danfoss GX snow melting cables are the basis of an electric snow melting system designed to ease the snow removal process as well as lessen its environmental impact The GX system is both efficient and economical It consists of twin conductor heating cables and a single point connection with a 20 6m power lead Danfoss GX cables are CSA certified Snowmelting cables mats suitable for concrete asphalt pavers and stonework Ideal for driveways parking lots sidewalks stairs ramps loading areas and bridges Reduces the environmental impact of snow and ice removal by eliminating the use of fossil fuel driven snow blowers snowplows rock salt and or other chemicals e Silent efficient automatic and safe e Single point connection e Zero EMF s e Genuine ten year warranty Danfoss GX Cable Mat Specifications Type Twin conductor Voltage 208 240 277
23. ief period of time Ensure the cable is fully rolled out when this is done Special care must be taken not to damage the heating cables when they are installed under bricks or tiles The area must be completely level and free of stones or other sharp objects The heating cable must be installed close to the bricks or tiles typically in a layer of sand at least 1 2 5 cm under the brick 3 max STONEWORK GX HEATING MAT CABLE O O 00 000 SAND CRUSHED STONE AND OR INSULATION GROUND 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 13 DANFOSS EXTENDED WARRANTY THE FOREGOING WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED ON THE PART OF DANFOSS DANFOSS DISCLAIMS ANY WARRANTY EXPRESS OR IMPLIED OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE DANFOSS NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON FIRM OR CORPORATION TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH SALE OR PRODUCT DANFOSS SHALL NOT BE HELD RESPONSIBLE FOR DAMAGE TO PERSON OR PROPERTY CONSEQUENTIAL LOSS LOSS OF PROFIT LOSSES ON GOODS IN STORE OR THE LIKE WHICH MIGHT ARISE OUT OF THE FAILURE OF THE EQUIPMENT DELIVERED IRRESPECTIVE OF THE CAUSE INCLUDING FAULTY MANUFACTURE How to claim this warranty Contact the company s Customer Service department and provide the following information 1 2 3 4 5 Nature oft
24. limitation de la temp rature e Le tapis ou cable GX doit tre int gr au mortier ou au m lange de mortier au b ton au sable ou un mat riau semblable e Il faut que la connexion du fil de courant et du cable de chauffage et au moins 30 cm 1 pi du fil de courant soient int gr s l int rieur du pavement e Le reste du fil de courant doit passer dans le conduit e _ Le fil de courant peut tre allong au besoin e _N installez pas les cables Danfoss GX de fa on que deux cables de chauffage noirs se touchent se croisent ou se chevauchent N oubliez pas de toujours mesurer v rifier et consigner la r sistance r elle tout au long du proc d d installation 1 En sortant le dispositif de la bo te 2 Apr s l installation 3 Avant de verser le sable le b ton ou l asphalte 4 Suite la pose du mat riau de surface Consignez les valeurs obtenues sur le tableau figurant la page 20 et sur la carte de garantie Le non respect de cette consigne annulera la garantie e Mesurez la distance entre les deux conducteurs charg s ainsi que la r sistance entre chaque conducteur et le fil de mise la terre e N oubliez pas de vous assurer que la tension d alimentation est la m me que la tension que requiert votre produit Danfoss GX e N oubliez pas d apposer les tiquettes tel qu indiqu dans le pr sent manuel e Les structures ou mat riaux m talliques utilis s pour le soutien ou l installation du
25. low the tube must be hard e g a concrete tile in order to ensure that the sensor is not pushed into the ground if for example a vehicle runs over it The tube is designed to be mounted on a plate using the two screw holes inside the conduit 4 A metal plastic pipe through which the sensor cable may be passed should be run as far as the sensor conduit 5 Coil approx 1 5 0 5m of the sensor cable inside the conduit 6 Place the sensor inside the tube until it is horizontally flush with the edge of the conduit and resting on the internal collar inside the conduit The sensor may be extracted at a later date using the two holes found around the edge of the sensor conduit The grooves on the outside of the sensor should correspond with the holes in the conduit Installation of conduit with sensor cable Installation in Asphalt Copyright 2009 Danfoss Inc The temperature must not exceed 176 F 80 C around the sensor tube A wooden block or similar place holder may be used in the area where the tube sensor can be placed subsequently The installation pipe used for the sensor cable should in that case be a metal tube that can withstand high temperatures 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 6 Placement of Ground Sensors Correct placement of the sensor s is important for the system to work as intended Some basic guidelines follow The number of ground sensors 1 The more sensors added to the s
26. ls 2E or F are to be placed at the switchboard Labels 3E and F are to be placed in the room or area where the heating mat cable is installed Center to Center C C distance Copyright 2009 Danfoss Inc The C C distance is the distance between the GX cables GX mats have a preset C C distance Standard spacing for 50W sq ft 540W m is 3 7 5 cm In a typical application the C C distance should not exceed 4 and be less than 3 ifthe cables are installed as part of a total heating system If the C C distance is higher cold spots may form on the surface and incomplete melting may occur 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 8 Concrete Installation Copyright 2009 Danfoss Inc When installing Danfoss GX heating cables the following should be observed Begin installation as close as possible to electrical supply source The heating cable must not be cut or shortened or exposed to strain in the areas of the cold tail heating cable coupling Insulation can be installed to improve efficiency of the heating system When placing the sensors please see page 7 Special care should be taken not to damage the heating cables with tools and machinery during the installation and application of the surface material Ensure that all sharp stones and debris are removed from the area where the heating cables are going to be installed Should the cable become damaged during the installation process it is helpful to know
27. lt to cool to a temperature of 265 F 130 C maximum before pouring If using without sand or concrete allow asphalt to cool to 220 F 105 C before pouring directly on mats cables Ground sensors tubes should not be exposed to temperatures above 80 C 176 F The cables are normally covered by 2 inches of asphalt A perimeter of maximum 12 30 cm of asphalt should exist unheated around the embedded cables This allows for adjustment of the paving surface edge without damaging the heating cable The operating weight of the asphalt roller should not exceed 1000Ibs MAT EMBEDDED IN HEART Ke NES R ASPHALT SAND CONCRETE LS E ET AN GX HEATING MAT CABLE SAND CONCRETE EMBEDDING CRUSHED STONE AND OR INSULATION GROUND MAT EMBEDDED DIRECTLY IN ASPHALT ASPHALT GX HEATING MAT CABLE IN ASPHALT ALLOW ASPHALT TO COOL TO 220 F BEFORE POURING ON MATS CABLES CRUSHED STONE AND OR INSULATION GROUND Stonework Installation Copyright 2009 Danfoss Inc When installing heating cables the following should be observed Begin installation as close as possible to electrical supply source The heating cable must not be cut or shortened or exposed to strain in the areas of the cold tail heating cable coupling Insulation can be installed to improve efficiency of the heating system When placing the sensors please see page 7 e Special care should be taken not to damage the heating c
28. mat to the mesh reinforcement using tie wraps or cable strapping Do not fix the heating cable of the mat in such a way that it is compressed or strained it must be able to move Unroll the mat up to the point at which it is to be flipped and turned Use the figure on page 5 toalterthe mat Cut the tape using scissors and rotate the mat so that it can be unrolled to cover the area next to the already unrolled mat Do not cut the cable The cable can be carefully detached from the tape and then placed as free cable This feature can be very useful for curves and around drains or other obstructions Labels Labels 2E or F are to be placed at the switchboard Labels 3E and F are to be placed in the room or area where the heating mat cable is installed Installing the heating cable The GX cable must be laid out with even spacing over the entire area to be heated To ensure an accurate and easy method of installing the GX cable it is recommended to use Danfoss cable strapping Attach the cable strapping to the rebar or other supporting structure using tie wraps The strapping should be laid perpendicular to the direction the cable will be unrolled Space the strapping 3 75cm apart Secure the heating cable to the cable strapping at the correct center to center distance Do not secure the cable too tightly as this may damage the cable If not using the cable strapping affix the heating cable to the rebar or wire mesh using tie wraps Labels Labe
29. n y a aucune pochette d air dans le mat riau de surface car cela pourrait endommager le c ble e Il faut installer un d branchement en amont pour disposer d une fa on de mettre sous tension le c ble ou le tapis basse temp rature le c ble de chauffage se raidit et il peut devenir difficile de le travailler Pour viter ce probl me branchez le c ble au secteur pendant une br ve p riode Assurez vous que le c ble est compl tement d roul pour ce faire 088L3370 06 09 T l 1 866 676 8062 T l c 905 285 2055 22 Installation dans le b ton suite Il doit y avoir au moins 3 8 cm 1 5 po couvrant les c bles de chauffage Selon le versement et l application il pourrait s av rer n cessaire d avoir une couverture plus paisse e Assurez vous que le c ble libre soit fix intervalles d au moins 45 cm 3 pi car le b ton peut d placer le cable lors de son versement e Le m lange de b ton ne doit pas contenir de pierres tranchantes car cela pourrait endommager le c ble e Le b ton doit s cher pendant 30 jours avant de mettre les c bles de chauffage sous tension B ton n gt CA a saaan Ta pis de chauffage GX Pierres concass es et ou isolation Sol Tous droits r serv s 2009 Danfoss Inc 088L3370 06 09 T l 1 866 676 8062 T l c 905 285 2055 23 Installation dans l asphalte Tous droits r serv s 2009 Danfoss Inc Lors de
30. noted Mat Alterations The GX heating mats can be altered to accommodate drains obstructions or bends in the layout By carefully cutting the mat tape many patterns and designs can be created The figure below illustrates this How tooutihe ral Direction cheng ANOS TY obstaces metro Extending th cols kad by using hezbngvare ack r k T zoi LA a f Free Cable and Cable Strapping Should the Danfoss cable strapping be used for the GX cable follow the instructions below for ease of installation Copyright 2009 Danfoss Inc 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 5 Installing a Feeder Cable For use with Gx850 and or ground sensors not applicable when using DS 2B A feeder cable for a sensor may be needed A 50 15m cable is supplied with each sensor Approx 1 5 0 5m of this cable should be coiled inside the bottom of the sensor tube The remaining cable may be lengthened The feeder cable must be a four wire cable Installing a Sensor and a Conduit The sensor and the conduit may be installed in connection with the actual construction work and connected at a later date The following applies for all types of installations 1 Ensure that the conduit is sealed when the concrete is poured 2 The conduit must be positioned so that it is flush with the surrounding terrain The sensor must be placed so that the upper brass surface is horizontal 3 The base be
31. s the concrete might move the cable when it is poured The concrete mixture must not contain sharp stones as these may damage the cable The concrete should be allowed to set for 30 days before the heating cables are turned on It is not recommended for the GX mat or cable to cross an expansion joint CONCRETE GX HEATING MAT CABLE CRUSHED STONE AND OR INSULATION GROUND Copyright 2009 Danfoss Inc 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 10 Asphalt Installation When installing heating cables the following should be observed Begin installation as close as possible to electrical supply source The heating cable must not be cut or shortened or exposed to strain in the areas of the cold tail heating cable coupling Install cables in a direction perpendicular to the direction that the paving rollers will pass to prevent straining or damaging the cable Insulation can be installed to improve efficiency of the heating system When placing the sensors please see page 7 Special care should be taken not to damage the heating cables with tools and machinery during the installation and application of the surface material Ensure that all sharp stones and debris are removed from the area where the heating cables are going to be installed Should the cable become damaged during the installation process it is helpful to know the location of the cold tail heating cable connection Tak
32. sprit tant aux propri taires de maison qu aux entrepreneurs Con ue pour une utilisation avec l asphalte le b ton et les dalles la fondeuse neige Danfoss GX est la fois polyvalente et facile installer Elle fonctionne automatiquement en d tectant num riquement l humidit et la temp rature Le dispositif GX est pos lors de l installation du rev tement de sol II faut donc poser certaines commandes et accessoires ce moment Il est recommand d installer l isolation thermique sous les cables ou tapis de chauffage Le rendement et l efficacit accrus permettront une r duction des co ts de fonctionnement MISE EN GARDE Il est important de faire installer cet quipement par un lectricien qualifi qui conna t les dimensions l installation la construction et le fonctionnement d appareils de chauffage ext rieurs et les risques associ s L appareil GX a t con u uniquement aux fins d utilisation l ext rieur pour faire fondre la neige et la glace Nota Lors de l installation il faut respecter les instructions du fabricant de m me que les codes lectriques nationaux et locaux Il est n cessaire de respecter la partie 426 de l American National Standard Institute National Fire Protection Association ANSI NFPA70 le Code national de l lectricit et le Code canadien de l lectricit partie 1 Vous devez utiliser un dispositif de protection contre les d fauts de terre et un dispositif de cour
33. uger D roulez le tapis jusqu l endroit o il faut le tourner ou l inverser Ayez recours l illustration la page 5 pour modifier le tapis Coupez le ruban avec des ciseaux et tournez le tapis de fa on pouvoir le d rouler pour couvrir la surface c t du tapis d j d roul Ne coupez pas le c ble On peut d tacher d licatement le c ble du ruban et le placer comme c ble libre Cela peut tre tr s utile en cas de courbe et pour faire le tour de drains ou d autres obstructions tiquettes Placez les tiquettes 2E ou F sur le tableau de contr le Les tiquettes 3E et F doivent tre plac es dans la pi ce ou dans le lieu o on installe le tapis ou c ble de chauffage Installation du c ble de chauffage Le c ble GX doit tre dispos de fa on uniforme sur toute la surface chauffer Pour assurer une installation correcte et facile du c ble GX il est recommand d utiliser les courroies de c ble Danfoss Fixez les courroies la barre d armature ou une autre structure de soutien au moyen d attaches Les courroies doivent tre dispos es la perpendiculaire par rapport au sens de d roulement du c ble Espacez les 75 cm 3 pi les unes des autres Fixez le c ble de chauffage aux courroies la bonne distance de centre centre Ne fixez pas le c ble trop serr car cela pourrait l endommager Si vous n utilisez pas de courroies fixez le c ble de chauffage la barre d armature ou au treillis
34. utilisez qu un d tecteur vous devrez d cider de ce qui est le plus important entre a b une d tection et une activation rapides du dispositif et assurer la fonte compl te de toute la neige ou glace Un dispositif un seul d tecteur est plus lent qu un dispositif deux d tecteurs en ce qui a trait la d tection et l activation car un des deux d tecteurs mesure la temp rature au sol alors que l autre mesure l humidit Placement du d tecteur au sol individuel Tous droits r serv s 2009 Danfoss Inc 1 Le d tecteur doit tre plac l int rieur de l aire de chauffage et au moins 1 m 3 pi 3 po du bord de la surface si possible 2 Le d tecteur doit tre plac entre les c bles de chauffage Une distance d au moins 1 cm 0 4 po doit tre maintenue entre le tube du d tecteur et le c ble de chauffage 3 Il doit y avoir une distance d au moins 1 m 3 pi 3 po entre les deux d tecteurs aml 3 N f A Fe 1 en oa po So gt FR i y Fra gt la d a E i 1 ye of N w Bo te de connexion C ble d alimentation 088L3370 06 09 T l 1 866 676 8062 T l c 905 285 2055 20 Installation du tapis de chauffage Commencez en fixant le tapis de chauffage l armature en treillis au moyen des attaches ou des courroies de cable Ne fixez pas le c ble de chauffage de fa on le comprimer ou l allonger il doit pouvoir bo
35. ystem the better the performance 2 The basic principle is to place one sensor where the snow ice will appear first for fast detection and one sensor where the snow ice will disappear last for complete melting If it is not obvious just place the sensors as far apart from each other as possible 3 With only one sensor you will have to decide what is most important a fast detection and activation of the system or b securing a complete melting of all snow ice A one sensor ground system will be slower in terms of detection and activation than a two sensor ground system where one sensor measures the ground temperature and the other sensor measures the moisture 4 With more than two sensors it is possible to cover problem spots where snow usually is not detected or where snow is not completely melted when the system stops Placement of Individual Ground Sensors 1 The sensor must be placed within the heated area and at least 3 3 1 m from the edge of the area if possible 2 The sensor must be placed in between the heating cables a distance of minimum 0 4 1 cm should be maintained between the sensor tube and the heating cable 3 There must be a distance of minimum 3 3ft 1 m between the two sensors Junction box Feeder cable Copyright 2009 Danfoss Inc 088L3370 06 09 TEL 866 676 8062 FAX 905 285 2055 7 Installing the heating mat Begin by fastening the heating