1. A O BB CA A110 P oF SELE Lock Control Module bons Module de contr le de verrouillage Range Online Access Control Gamme Contr le d Acc s centralis INSTALLATION MANUAL MANUEL D INSTALLATION C DV I Group Products The CA A110 P Lock Control Module has been specifically designed to greatly reduce installation time and simplify the connection of electromagnetic locks when used alone or in conjunction with door strikes The CA A110 P Lock Control Module consists of two onboard heavy duty 12V relays two inputs for fire alarm contacts and two relay activation LED indicators The relays which are used to control power to the electromagnetic locks are toggled by the activation of the controller s lock output terminals or the CA A110 P s fire alarm contact inputs 1 INSTALLATION INSTRUCTIONS POPP e oO SOLE SE EEE EEEEHE EEE EEEE EEE TTEEEE EH EEEOEE EE TEEHEEETOLEEE EEE EOEEEEHOEETEE EEE SEEEHETTOEOEE EE TEOEEEEREEESEH EE EEEEEE ER OLESEHEEEEEEEEETOLEOEH EE LEEEEEEDOLESEL EEE EEED EEO LEEEE EE EEEEEEELEOLS Short contacts Door strike 1 if not used v Jo 1 Fire ala
2. CA A110 P 1 INSTALLATION Si les contacts ne sont pas utilis s court circuitez les G che 1 Contact alarme Contact alarme Ventouse 1 Alimentation incendie pour incendie pour I ventouse 1 ventouse 2 y 7 UNLKI UNLK2 i JP10 LK1 Activation relais 1 Le LED verte JPI2 LK2 GND Verrouillage Ventouse 2 LK1 LK1 JP12 LK2 a 12V LK2 Alimentation ZON ZON ZO TON TON TO A z GND Verrouillage 24V 2 Activation relais 2 LED Verte Centrale CT V900 A Vue partielle intensit nominale des contacts 5A avec protection du retour par diodes Dans l installation ci dessus lorsque l acc s porte 1 est autoris la sortie LK1 va tre activ e de fa on d clencher la porte 1 Le relais 1 du module CA A110 P va basculer aussi coupant l alimentation du verrouillage lectromagn tique de la porte 1 ayant pour effet ded verrouiller celle ci Dans le cas d une alarme incendie le contact de l alarme incendie pour le verrouillage 1 va s ouvrir faisant basculer le relais 1 du module CA A110 P en coupant l alimentation du verrouillage l
3. ectromagn tique 1 Remarque L activation d un relais par le contact de sortie de la commande de verrouillage d un servo r gulateur va allumer le voyant DEL d activation de relais appropri vert 2 relais type C 12 V CC 2 entr es d alarme incendie contacts normalement ferm s 305 m 1000 pieds utilisant une paire 22 AWG 2 voyants DEL d activation de relais vert IMPORTANT 1 Vous devez toujours consulter la r glementation locale sur le B timent et ou demander au service des sapeurs pompiers de votre localit l envoi de la r glementation la plus r cente relative au type d installation envisag La r glementation peut diff rer d un b timent un autre La connaissance de ces r gles avant la conception d un syst me sera pour vous synonyme de gain de temps et d argent et vitera un ventuel pr judice votre client Les concepteurs et les installateurs professionnels 2 CARACTERI STI QUES TECHNIQUES Aucune source d alimentation ext rieure pr voir 2 relais activ s par les contacts de sortie de la commande de verrouillage du servo r gulateur Intensit maximale absorb e 100 mA sous 12 V CC Tension maximale de sortie de la commande de verrouillage du CT V900 A 12 V CC doivent s assurer qu un syst me alternatif d ouverture ou de d verrouillage des portes est pr vu Certains pays autorisent ventuellement l utilisation d un poste manuel sp cifique de d verrouillage de
4. o external power source required relays activated p q y installation professionals to ensure that an alternative by a controller s lock outputs Maximum current consumption 100mA 12Vdc means to open or unlock the doors are provided CT V900 A lock output voltage is not to exceed 12Vdc Some countries may accept the use of a specific 2 Form C Relays 12Vdc SA contact rating manual station to unlock the door others may with diode flyback protection 2 Fire Alarm Inputs Normally closed contacts require that the fire alarm system unlock 305m 1000 feet using 22AWG pair the doors automatically in case a fire is detected cdvi com 2 cdvigroup com JEL D INSTALLATI ON CA A110 P Module de contr le de verrouillage Le contr leur de verrouillage CA A110 P a t sp cialement con u pour r duire sensiblement les temps d installation et simplifier le branchement des verrouillages lectromagn tiques lorsqu ils sont utilis s seuls ou lors des ouvertures de porte Le contr leur de verrouillage CA A110 P comporte deux relais de puissance incorpor s de 12 V deux entr es pour les contacts d alarme incendie et deux voyants LED d activation de relais Le basculement des relais qui permettent de contr ler l alimentation des verrouillages lectromagn tiques s effectue par l activation des bornes de sortie du syst me de verrouillage du servo r gulateur ou des contacts d entr e de l alarme incendie du
5. porte autres pays peuvent exiger que le syst me d alarme cdvi com cdvigroup com 5 Reference GO301FR0O25 V02 Extranet EXE CDVI_IM CA A110 P CMYK A5 EN FR 02 Manufacturing Access Control since 1985 CDVI Headquarters Si ge social FRANCE Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX Phone 32 0 56 62 02 50 Fax 32 0 56 62 02 55 CDVI TAIWAN Phone 0 42471 2188 Fax 0 42471 2131 CDVI SWITZERLAND Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 87664065 Fax 86 0 10 87664165 CDVI IB RICA Phone 34 935 390 966 Fax 34 935 390 970 CDVI ITALIA Phone 39 0331 97 38 08 Fax 39 0331 97 39 70 1d dimensions could be changed without prior notice dessins caract ristiques et c tes sont susceptibles LA G CHE LECTRIQUE FRANCE Phone 33 0 3 88 77 32 82 Fax 33 0 3 88 77 85 02 CDVI MAROC Phone 212 5 22 48 09 40 Fax 212 5 22 48 34 69 CDVI SWEDEN Phone 46 0 31 760 19 30 Fax 46 0 31 748 09 30 CDVI UK Phone 44 0 1628 531300 Fax 44 0 1628 531003 DIGIT FRANCE Phone 33 0 1 41 71 06 85 Fax 33 0 1 41 71 06 86 I cdvigroup com
6. rm contact Fire alarm contact a Electromagnetic Lock 1 POWER SUPPLY for Lock 1 K H for Lock 2 2 a q dh 2 JP10 LK1 _ T Relay 1 activation JP12 LK2 i LED 1 LED Green a GND gt a le Ao eS SO gt LOCK 1 Electromagnetic Lock 2 POWER SUPPLY 0 Na Dm nn Ts nt gt zs S an nn gt gt LOCK 2 CAE SES E e gt Fal Door strike 2 Ny Relay 2 activation OST AE CT V900 A Controller Partial view Q 1 In the above installation when access is granted 2 Relay Activation LED Indicators Green to door 1 output LK1 will be enabled in order to power door strike 1 Relay 1 of the CA A110 P will IMPORTANT NOTES also toggle cutting power to electromagnetic lock 1 Pe thus unlocking the door In the case of a fire alarm 1 You should always consult your local building code thefirealarmcontactforLock1 willopen togglingrelay and or fire marshal to receive the most up to date 1 of the CA A110 P cutting power to electromagnetic regulations that apply to the type of installation lock 1 Please note that when arelay is being activated you are planning to do Different rules may apply by a controller s lock output the appropriate Relay Activation LED green will illuminate to different types of buildings Knowledge of the rules before designing a system will save you 2 SPECIFICATIONS time money and possible injury to your client See eee ae eee eee ee Die D E N
Download Pdf Manuals
Related Search
Related Contents
Magnum CS14 & CSN14 Converter Switch Installation and User Guide 契約締結前交付書面 Panasonic MC-V5003 Vacuum Cleaner User Manual Samsung ST6500 Керівництво користувача 取扱説明書 - ミネベア Hahnel 1000 765.0 - Pro Tune User manual Package Listing CFX-SR-6520 製品情報PDFダウンロード DreamLine SHEN-6134600-08 Installation Guide Copyright © All rights reserved.