AMETEK XPH65-2D Operation Manual
Contents
1. conectada O alimentaci n principal OFF Precauci n posible peligro Consulte la documentaci n este manual para averiguar el tipo de desconectada riesgo potencial y qu acciones deben tomarse 25 Instalaci n Tensi n de la Red El ctrica Este instrumento tiene un rango de entrada universal y funcionar sin necesidad de ajustes en suministros el ctricos de 115V o 230V Compruebe que el suministro local satisface los requisitos de entrada CA que se estipulan en Especificaciones Cable de red Conectar el instrumento al suministro de CA usando el cable de la red incluido Si requiere un enchufe de la red para una toma de energ a diferente deber utilizar un conjunto de cable de la red aprobado con la capacidad adecuada provisto del enchufe de pared requerido y un conector IEC60320 C13 para el extremo del instrumento Para determinar la capacidad minima de corriente del conjunto del cable para el suministro de CA espec fico leer las Especificaciones o la informaci n referente a la potencia de salida del equipo ADVERTENCIA ESTE INSTRUMENTO DEBE CONECTARSE A TIERRA Cualquier interrupci n del conductor a tierra dentro o fuera del instrumento implicar a que el instrumento resultara peligroso Est prohibida cualquier interrupci n intencional Ventilaci n 26 El suministro de fuerza es muy eficaz pero puede generar mucho calor a fuerza plena El suministro depende de enfriamiento por convecci n solamente y p
2. OUTPUT Ausgang anzuschlie en Nehmen Sie den Anschlu an an einen oder beide Ausg nge vor dem gew hlten Modus entsprechend Siehe hierzu Betriebsabschnitt Achtung Spannungen ber 70 VDC sind nach EN 61010 1 lebensgef hrlich Daher ist bei Netzteilspannungen ber diesem Wert u erst vorsichtig vorzugehen Die Universal Sicherheitsanschlussklemmen am Ausgang entsprechen den Anforderungen f r verst rkte Isolierung bei Spannungen bis 250 VDC da Kriechweg und Abstand zu den Anschlusskontakten auch bei vollst ndig ge ffneten Anschlussklemmen gt 2 5 mm betragen Es wird jedoch sehr empfohlen die Anschlussklemmen immer ganz anzuziehen und Anschl sse nur mit Kabeln auszuf hren die mit 4 mm Sicherheitssteckern und fester Ummantelung ausgestattet sind Achten Sie darauf dass die angeschlossene Schaltung ausreichend isoliert ist Zug ngliche Teile der externen Schaltung d rfen unter normalen oder St rbedingungen keine lebensgef hrliche Spannungen f hren siehe EN61010 1 Anschl sse am Ger t nur bei abgeschaltetem OUTPUT ausf hren Die mit dem Symbol gekennzeichnete Klemme ist mit dem Chassis und der Schutzerde verbunden Betrieb Bei Modus A unabh ngiger Modus ist der Betrieb beider Ausg nge identisch Die anschlie ende Beschreibung gilt f r beide Bei Modus B und C ist nur Ausgang 2 aktiv w hrend Ausgang 1 deaktiviert ist Die Beschreibung gilt also nur f r Ausgang 2 Siehe Abschnitt ber Moduswahl Einst
3. e negativo nero Entrambi sono completamente liberi e possono essere connessi a terra Attenzione Le tensioni superiori a 70 V c c sono pericolose secondo le indicazioni della norma EN 61010 1 prestare molta attenzione quando si utilizza un alimentatore con tensioni superiori a questo valore Si consiglia di effettuare le connessioni usando solo cavi provvisti di morsetti a cappuccio da 4 mm a schermatura fissa Accertarsi che il circuito a cui vengono effettuate le connessioni sia opportunamente isolato in conformit alla norma EN61010 1 evitare che in condizioni normali o in presenza di un singolo guasto i componenti accessibili del circuito esterno vadano sotto tensione creando una condizione di pericolo Effettuare sempre le connessioni allo strumento con OUTPUT disattivato Collegamento in serie parallelo con altre uscite A A Le uscite del dispositivo di alimentazione sono completamente flottanti e possono essere usate in serie con l uscita di altri dispositivi si alimentazione per generare tensioni pi alte fino a 300V c c Attenzione Le tensioni superiori a 70 V c c sono pericolose come specifica la norma EN 61010 1 prestare molta attenzione quando si utilizza un alimentatore con tensioni superiori a questo valore La tensione massima ammessa tra un morsetto qualsiasi e il morsetto di terra e 300Vc c la tensione massima ammessa tra un morsetto dell uscita e gualsiasi morsetto di un altra uscita sulla stessa
4. because the supply has developed a fault in such circumstances the instrument will need to be returned to the manufacturer for service Make sure that only fuses of the required rated current and specified type are used for replacement The use of makeshift fuses and the short circuiting of fuse holders is prohibited To replace a fuse first disconnect the instrument from the AC supply Remove the 6 cover securing screws and lift off the cover Replace the fuse with one ofthe correct type and refit the cover Cleaning If the PSU requires cleaning use a cloth that is only lightly dampened with water or a mild detergent Polish the display window with a soft dry cloth WARNING TO AVOID ELECTRIC SHOCK OR DAMAGE TO THE PSU NEVER ALLOW WATER TO GET INSIDE THE CASE TO AVOID DAMAGE TO THE CASE OR DISPLAY WINDOW NEVER CLEAN WITH SOLVENTS 10 Securite Cet instrument est de Classe de s curit 1 suivant la classification IEC et il a t construit pour satisfaire aux imp ratifs EN61010 1 Imp ratifs de s curit pour le mat riel lectrique en vue de mesure commande et utilisation en laboratoire Il s agit d un instrument d installation Cat gorie Il devant tre exploit depuis une alimentation monophas e habituelle Cet instrument a t soumis des essais conform ment EN61010 1 et il a t fourni en tout tat de s curit Ce manuel d instructions contient des informations et avertissements qui doivent tre suivis p
5. con la salida de tensi n OUTPUT en posici n OFF El borne marcado est conectado al bastidor y a la seguridad de tierra 7 Operacion El funcionamiento de ambas salidas es id ntico en el Modo A modo independiente la siguiente descripci n corresponde a ambas En el Modo B y Modo C s lo est activa la salida 2 mientras que la salida 1 est inhabilitada por lo tanto la descripci n s lo corresponde a la salida 2 ver el apartado Selecci n de modo Ajuste de la Salida Con el interruptor POWER conectado I y se pueden preajustar la salida de la tensi n de salida y el l mite de corriente con precisi n usando los controles de VOLTAGE y CURRENT el medidor a la izquierda indica la tensi n ajustada y el medidor a la derecha indica la corriente m xima preajustada Cuando se conecta el interruptor de salida se ilumina la l mpara ON ahora el medidor a la izquierda indica la tensi n efectiva y el medidor a la derecha indica la corriente de carga efectiva Tensi n Constante Se ajusta la tensi n de salida usando los controles fino y grueso de VOLTAGE Tensi n el control de CORRIENTE ajuste la corriente m xima que se puede suministrar Corriente Constante Si la resitencia de carga es suficientemente baja tal que con la tensi n de salida ajustada correr una corriente mayor que el limite de corriente ajustado y la a imentaci n el ctrica cambiar autom ticamente a operaci n con corriente constante S
6. glage de limite de courant puisse passer pour la tension de sortie r gl e l alimentation passera automatiquement en mode de fonctionnement de courant constant La commande CURRENT ajuste le courant de sortie et les commandes VOLTAGE r glent la tension maximale qui peut tre engendr e Le t moin CC s allume pour indiquer le mode de courant constant Sortie de courant instantan e Il est possible de r gler la commande de limite de courant pour limiter le courant de sortie continu des niveaux aussi bas que 10 mA Toutefois ainsi que c est le cas de toutes les alimentations de pr cision sur banc un condensateur est reli aux bornes de la sortie afin de maintenir la stabilit ainsi qu une bonne r ponse transitoire Ce condensateur se charge jusqu la tension de sortie et le court circuitage de la sortie produira une impulsion de courant lors du d chargement du condensateur ind pendamment du r glage de limite de courant S lection de mode A 12 Les trois modes de fonctionnement sont s lectionn s par le commutateur rotatif du panneau avant situ entre les bornes Attention D sactiver les deux sorties avant de changer de mode On risque en effet d endommager le circuit aliment ainsi que l appareil en question si le mode est op rationnel lorsqu une des deux sorties est toujours activ e Mode A Le commutateur dans cette position les sorties fonctionnent ind pendamment et elles sont isol es l une de l au
7. le circuit sur lequel sont effectu es les connexions est correctement isol aucune des pi ces accessibles du circuit externe ne devrait tre dangereuse lorsque l appareil est sous tension dans des conditions normales ou lorsqu une seule faute est d tect e conform ment la norme EN61010 1 OUTPUT sortie doit toujours tre hors tension lors de la connexion l instrument Connexion en s rie ou en parall le avec d autres sorties A A Les sorties de l alimentation sont enti rement flottantes et elles peuvent tre utilis es en s rie avec d autres blocs d alimentation afin de produire des tensions c c jusqu 300 V c c Avertissement Les tensions sup rieures 70 Vcc sont dangereuses sous tension selon la norme EN 61010 1 et le plus grand soin doit tre pris lors de l utilisation de tensions sup rieures ce niveau La tension maximale admissible entre une borne et la terre gt est de 300 V c c la tension maximale admissible entre la borne d une sortie et la borne d une autre sortie de la m me alimentation est galement de 300 V c c AVERTISSEMENT Effectuer toutes les connexions aux bornes la sortie d sactiv e tous les appareils Il faut noter que le bloc peut uniquement recevoir du courant mais non le consommer de sorte qu il n est pas possible de mettre en opposition de phase les blocs reli s en s rie Il est possible de relier le bloc en parall le avec d autres afin de produire des courant
8. produrranno un impulso di corrente che indipendente dall impostazione della limitazione di corrente Selezione della modalit A 22 Le tre modalit di funzionamento si selezionano mediante il commutatore rotativo situato tra i morsetti sul pannello anteriore Attenzione Prima di cambiare la modalit spegnere ambedue le uscite Si possono causare danni al circuito che si vuole alimentare e all unit stessa cambiando la modalit quando una delle uscite ancora accesa Modalit A Con il commutatore in questa posizione le uscite funzionano indipendentemente e sono isolate luna dall altra Ciascuna uscita ha un escursione della tensione fra 0 e 75V e della corrente fra 0 e 2A Modalit B Con il commutatore in questa posizione attiva solo l uscita 2 la tensione va da 0 a 75V e la corrente da 0 a 4A controlli dell uscita 1 sono fuori uso e la visualizzazione in bianco morsetti dell uscita 1 sono isolati da quelli dell uscita 2 Si voglia notare che con l interruttore dell uscita 1 acceso ON l indicatore d uscita si accende ma i morsetti rimangono in circuito aperto Si noti anche che l escursione e la scala del limite di corrente raddoppiano quando si cambia dalla modalit A alla B vale a dire che se il controllo del limite in A impostato a 1 5A il limite diviene 3A in modalit B Per evitare possibili danni al circuito sotto prova le uscite devono essere spente prima di cambiare la modalit e il limi
9. A Mode B Mode C METER SPECIFICATIONS Meter Types Meter Resolutions Meter Accuracies Operating Modes GENERAL AC Input Power Consumption Operating Range Storage Range Environmental Safety EMC Size Weight By front panel rotary switch Independent outputs each capable of 0 75V at 0 2A Output 2 only active 0 75V at 0 4A Output 1 disabled Output 2 only active 0 150V at 0 2A Output 1 disabled Dual 3 digit meters with 14mm 0 56 LEDs Reading rate 4 Hz 100mV 10mA Voltage 0 3 of reading 1 digit Current 0 6 of reading 1 digit Output 1 meters are blanked in Modes B and C 110V 240V AC 10 Installation Category II 500VA max 5 C to 40 C 20 to 80 RH 40 C to 70 C Indoor use at altitudes up to 2000m Pollution Degree 2 Complies with EN61010 1 Complies with EN61326 260 x 160 x 320mm WxHxD 4 3kg Safety This power supply is a Safety Class instrument according to IEC classification and has been designed to meet the reguirements of EN61010 1 Safety Reguirements for Electrical Eguipment for Measurement Control and Laboratory Use It is an Installation Category II instrument intended for operation from a normal single phase supply This instrument has been tested in accordance with EN61010 1 and has been supplied in a safe condition This instruction manual contains some information and warnings which have to be followed by the user to ensure saf
10. AMETEK PROGRAMMABLE POWER XPH Series 75V 2A Dual DC Power Supply Operation Manual Model XPH 75 2 M370287 01 Rev B www programmablepower com About AMETEK AMETEK Programmable Power Inc a Division of AMETEK Inc is a global leader in the design and manufacture of precision programmable power supplies for R amp D test and measurement process control power bus simulation and power conditioning applications across diverse industrial segments From bench top supplies to rack mounted industrial power subsystems AMETEK Programmable Power is the proud manufacturer of Elgar Sorensen California Instruments and Power Ten brand power supplies AMETEK Inc is a leading global manufacturer of electronic instruments and electromechanical devices with annualized sales of 2 5 billion The Company has over 11 000 colleagues working at more than 80 manufacturing facilities and more than 80 sales and service centers in the United States and around the world Trademarks AMETEK is a registered trademark of AMETEK Inc Other trademarks registered trademarks and product names are the property of their respective owners and are used herein for identification purposes only Notice of Copyright XPH Series 75V 24 Dual DC Power Supply Operation Manual 2007 2009 AMETEK Programmable Power Inc All rights reserved Exclusion for Documentation mee ie AGREED TO IN WRITING AMETEK PROGRAMMABLE POWER INC a MAKES NO WARRANTY AS TO T
11. HE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION b ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES DAMAGES COSTS OR EXPENSES WHETHER SPECIAL DIRECT INDIRECT CONSEGUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK AND c REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION THE ACCURACY CANNOT BE GUARANTEED APPROVED AMETEK CONTENT IS CONTAINED WITH THE ENGLISH LANGUAGE VERSION WHICH IS POSTEDAT WWW PROGRAMMABLEPOWER COM Date and Revision May 2010 Revision B Part Number M370287 01 Contact Information Telephone 800 733 5427 toll free in North America 858 450 0085 direct Fax 858 458 0267 Email sales programmablepower com service programmablepower com Web www programmablepower com Introduction Specification Safety Installation Connections Operation Maintenance Instructions en Francais S curit Installation Connexions Fonctionnement Maintenance Bedienungsanleitung auf Deutsch Sicherheit Installation Anschl sse Betrieb Wartung Istruzioni in Italiano Sicurezza Installazione Collegamenti Funzionamento Manutenzione Instrucciones en Espa ol Seguridad Instalaci n Conexiones Operaci n Mantenimiento W
12. Schutzvorrichtungen Der Ausgang ist mit einem eigenen Kurzschlu schutz versehen und mittels Diode vor Umkehrspannungen gesch tzt Kontinuierlicher Umkehrstrom darf 3 Amp nicht berschreiten Transiente Str me k nnen jedoch wesentlich h her liegen Der Ausgang ist vor extern angelegten Durchla spannungen von bis zu 85 V Modi A und B oder 170 V Modus C gesch tzt Anschlu an den Verbraucher A A Die Last sollte an die mit OUTPUT gekennzeichneten positiven rot und negativen schwarz Klemmen angelegt werden Beide Klemmen sind galvanisch getrennt und k nnen daher an Erde gelegt werden Achtung Spannungen ber 70 VDC sind nach EN 61010 1 lebensgef hrlich Daher ist bei Netzteilspannungen ber diesem Wert u erst vorsichtig vorzugehen Es wird sehr empfohlen den Anschluss nur mit Kabeln auszuf hren die mit 4 mm Sicherheitssteckern und fester Ummantelung ausgestattet sind Achten Sie darauf dass die angeschlossene Schaltung ausreichend isoliert ist Zug ngliche Teile der externen Schaltung d rfen unter normalen oder St rbedingungen keine lebensgef hrliche Spannungen f hren siehe EN61010 1 Anschl sse am Ger t nur bei ausgeschalteten Ausgang OUTPUT kontaktieren Reihen und Parallelschaltung mit anderen Ausg ngen A 18 Da der Ausgang des Netzteils vollst ndig potentialfrei ist kann er mit anderen Netzger ten zur Erzeugung hoher Gleichspannungen bis maximal 300V in Reihe geschaltet werden Achtu
13. Stromversorgung k nnen auch noch nach Abschalten s mtlicher Stromversorgung Spannung f hren sie entladen sich jedoch innerhalb von etwa 10 Minuten nach Spannungsabschaltung Jegliche Nachstellung Wartung und Reparatur am ge ffneten unter Spannung stehenden Ger t ist nach M glichkeit zu vermeiden Falls unvermeidlich sollten solche Arbeiten nur von gualifiziertem Personal ausgef hrt werden das sich der Gefahren bewu t ist Ist das Ger t eindeutig fehlerbehaftet bzw wurde es mechanisch besch digt berm iger Feuchtigkeit oder chemischer Korrosion ausgesetzt so k nnen die Schutzeinrichtungen beeintr chtigt sein weshalb das Ger t aus dem Verkehr zur ckgezogen und zur berpr fung und Reparatur eingesandt werden sollte Sicherstellen da nur Sicherungen der vorgeschriebenen Stromst rke und des vorgesehenen Typs als Ersatz verwendet werden Provisorische Sicherungen und der Kurzschlu von Sicherungshaltern ist verboten Beim Reinigen darauf achten da das Ger t nicht na wird Am Ger t werden folgende Symbole verwendet Erdungsklemme Gleichstrom Netz ON ein IN gt Wechselstrom Achtung Gefahr Lesen Sie bitte die Dokumentation dieses O AS A Handbuch um die Art der m glichen Gefahr und etwaige Gegenma nahmen herauszufinden 15 Installation Netzbetriebsspannung Das Ger t besitzt einen universellen Eingangsbereich und kann ohne jede weitere Einstellung mit einer Nenn Netzversorg
14. a gue la corriente suministrada supere el limite de corriente fijado lo gue resultar en la salida bajando al mayor limite siguiente fijado y asi sucesivamente En la modalidad de corriente constante las unidades pueden conectarse en paralelo para proporcionar una corriente igual a la suma de los limites de corriente fijados Se debe observar que la salida de los bornes est clasificada a un m ximo de 15A si varias salidas funcionan en paralelo para suministrar corrientes superiores a sta la junta debe efectuarse en un punto distinto y no en los bornes Mantenimiento Los fabricantes o sus agentes en el extranjero ofrecen un servicio de reparaci n para toda unidad que desarrolle un defecto Si los propietarios desearan establecer su propio servicio esto s lo debe realizarse por personas cualificadas en conjunto con el manual de servicio que puede adquirirse directamente del Fabricante o de sus agentes en el extranjero Fusible El tipo correcto del fusible es 10 Amperios 250V HBC retardo T 5 x 20mm Se debe observar que la funcci n principal del fusible es hacer seguro instrumento y limitar el da o en el caso de una aver a de uno de los dispositivos interruptores Si falla un fusible entonces es muy probable que el repuesto tambien se fundir porque se ha desarrollado una aver a en la alimentaci n el ctrica en tales circunstancias ser necesario devolver el instrumento al fabricante para una revisi n Asegurar que se em
15. alimentazione anch essa 300Vc c Tutti i collegamenti ai morsetti devono essere eseguiti con le uscite di tutte le unit spente da notare che questo dispositivo pu solo generare corrente e non pu dissiparla per questa ragione le unit non possono essere collegate in serie in antifase Il dispositivo pu essere collegato in parallelo con altri dispositivi di alimentazione per produrre correnti pi alte Quando vari gruppi sono collegati in parallelo la tensione d uscita sar uguale a quella del gruppo impostato sulla tensione pi alta fino a quando non si eccede il limite di corrente impostato a questo punto la tensione in uscita impostata scende al valore dell impostazione pi alta immediatamente inferiore e cosi via In modalit di corrente costante vari gruppi possono essere collegati in parallelo per erogare una corrente uguale alla somma dei limiti di corrente impostati 23 Manutenzione Produttori o i loro agenti all estero faranno le riparazioni necessarie in caso di guasto Qualora l utente desiderasse eseguire il lavoro di manutenzione tale lavoro deve essere fatto solo da personale qualificato e usando il manuale di servizio che pu essere acquistato direttamente dai Produttori o dai loro agenti all estero Fusibili Il tipo di fusibile corretto 10 Amp 250V ritardato T HBC 5 x 20mm da notare che la funzione principale del fusibile di rendere sicuro lo strumento e limitare i danni qualo
16. ar l utilisateur afin d assurer un fonctionnement de toute s curit et de conserver l instrument dans un tat de bonne s curit Cet instrument a t con u pour tre utilis en interne dans un environnement de pollution Degr 2 plage de temp ratures 5 C 40 C 20 80 HR sans condensation Il peut tre soumis de temps autre des temp ratures comprises entre 5 C et 10 C sans degradation de sa s curit Ne pas l utiliser lorsqu il y a de la condensation Toute utilisation de cet instrument de mani re non sp cifi e par ces instructions risque d affecter la protection de s curit conf r e Ne pas utiliser l instrument l ext rieur des tensions d alimentation nominales ou de la gamme des conditions ambiantes sp cifi es AVERTISSEMENT CET INSTRUMENT DOIT ETRE RELIE A LA TERRE Toute interruption du conducteur de terre secteur l int rieur ou l ext rieur de l instrument rendra l instrument dangereux II est absolument interdit d effectuer une interruption dessein Ne pas utiliser de cordon de prolongation sans conducteur de protection car ceci annulerait sa capacit de protection Lorsque l instrument est reli son alimentation il est possible que les bornes soient sous tension et par suite l ouverture des couvercles ou la d pose de pi ces l exception de celles auxquelles on peut acc der manuellement risque de mettre d couvert des pi ces sous tension II faut d brancher toute sou
17. ario per l alimentazione utilizzata fare riferimento ai dati di potenza indicati sull apparecchio stesso o nelle corrispondenti specifiche tecniche ATTENZIONE QUESTA STRUMENTO DEVE ESSERE COLLEGATA ALLA TERRA Una qualsiasi interruzione sia interna che esterna del collegamento a terra lo rende pericoloso E proibito interrompere questo collegamento deliberatamente Ventilazione Il dispositivo di alimentazione molto efficiente ma a piena potenza pu generare una quantit significativa di calore Il raffreddamento per convezione ed perci importante che la ventilazione non sia mai ristretta se si vogliono mantenere i livelli ottimali di rendimento e sicurezza Se il dispositivo montato in uno spazio ristretto ad es su una rastrelliera da 19 pollici si deve provvedere una ventilazione adeguata usando ad esempio una base fornita di ventola Collegamenti collegamenti vanno eseguiti tutti dal pannello frontale Il carico deve essere collegato ai morsetti positivo rosso e negativo nero che sono contrassegnati OUTPUT Uscita Collegare a un uscita o all altra come appropriato a seconda della modalit selezionata Vedere la sezione Funzionamento 1 prestare molta attenzione quando si utilizza un alimentatore con tensioni superiori a questo h Attenzione Le tensioni superiori a 70 V c c sono pericolose come specifica la norma EN 61010 valore Gli adattatori a vite di sicurezza universali utilizzati per l us
18. arranty Information Table of Contents OND O dI ODO Ww 10 11 11 12 14 19 16 16 17 19 20 21 21 22 24 25 26 26 27 29 30 Introduction The XPH 75 2D is a dual output 300 watt PSU with Multi Mode capability in a compact and attractive case The Multi Mode capability enables it to operate as a dual power supply with two independent and isolated outputs or as a single power supply of double the power As a dual each output provides 0 to 75V at 0 to 2A Mode A As a single the output can be selected as either 0 to 75V at 0 to AA Mode B or 0 to 150V at 0 to 2A Mode C In single modes the unused half of the unit becomes completely inoperative and its displays are blanked The EX series incorporates separate digital voltage and current meters on each output The meters use bright 14mm 0 56 LED displays and have an update rate of 4 per second providing near instantaneous response Simultaneous metering of voltage and current provides accurate information at a glance and avoids any possibility of misinterpretation When an output switch is set to off the current limit setting is displayed enabling conditions to be set before the load is connected Excellent line and load regulation are matched by low noise and good transient response High power efficiency ensures that the unit remains cool without any fan noise The XPH 75 2D has been designed to meet the stringent requirements of relevant IEC s
19. atorio Es un instrumento de Categoria de Instalaci n Il propuesto para ser usado con un suministro monof sico normal Este instrumento ha sido comprobado seg n la norma EN61010 1 y ha sido suministrado en una condici n segura El manual de instrucciones contiene informaci n y advertencias que deben seguirse para asegurar el empleo seguro por el usuario y para mantener al instrumento en una condici n segura Este instrumento ha sido dise ado para ser utilizado en el interior en un ambiente de Grado de Poluci n 2 a temperaturas de entre 5 C y 40 C y una humedad relativa de entre el 20 y el 80 sin condensaci n De manera ocasional puede someterse a temperaturas de entre 5 C y 10 C sin que ello afecte a su seguridad No hay que ponerlo en funcionamiento mientras haya condensaci n El uso de este instrumento en una manera no especificada por estas instrucciones puede afectar a la seguridad protectora provista El instrumento no debe ser utilizado fuera de su clasificaci n de voltaje o de su gama ambiental ADVERTENCIA ESTE INSTRUMENTO DEBE CONECTARSE A TIERRA Cualquier interrupci n del conductor a tierra dentro o fuera del instrumento implicar a que el instrumento resultara peligroso Est prohibida cualquier interrupci n intencional La acci n protectora no debe negarse por el uso de una extensi n de cable sin conductor protector Cuando el instrumento est conectado a su suministro es posible que queden sin protecci
20. cir ajustando los controles a 60V en el Modo B el voltaje de salida se convierte en 120V en el Modo C Por lo tanto se ha de tener cuidado para asegurar que las salidas se desconectan antes de que se cambie el modo y que la salida est configurada al voltaje correcto antes de que se conecte Protecci n La salida tiene protecci n intr nsica contra cortocircuitos y est protegida contra tensiones de polaridad invertida mediante un diodo La corriente continua al rev s no debe exceder 3 Amperios aunque las ondas transitorias pueden estar mucho superior a esto La salida est protegida contra tensiones directas aplicadas externamente de hasta 85V Modos A y B o 170V Modo C Conexi n a la Carga A A La carga debe conectarse a los terminales OUTPUT positivo rojo y negativo negro Ambas son totalmente flotantes y cualquiera de ellas puede ser conectada a tierra Precauci n De acuerdo con la norma EN 61010 1 los voltajes por encima de 70 V de corriente continua se consideran tensi n peligrosa por lo que deber adoptarse especial cuidado al utilizar la fuente de alimentaci n por encima de estos valores Se recomienda encarecidamente realizar las conexiones nicamente con cables que contengan patillas de seguridad de 4 mm con protector fijo Aseg rese de que el circuito en el que se realicen las conexiones est correctamente aislado ninguna parte accesible del circuito externo deber presentar tensiones el ctricas pe
21. cita soddisfano i reguisiti di isolamento rinforzato per tensioni fino a 250 V c c in quanto la dispersione e la distanza dai contatti del morsetto sono superiori a 2 5 mm anche quando l adattatore a vite completamente aperto Si consiglia comunque di stringere completamente i morsetti a vite e di effettuare le connessioni usando solo cavi provvisti di spine di protezione da 4 mm a schermatura fissa Accertarsi che il circuito a cui vengono effettuate le connessioni sia opportunamente isolato in conformit alla norma EN61010 1 evitare che in condizioni normali o in presenza di un singolo guasto i componenti accessibili del circuito esterno vadano sotto tensione q creando una condizione di pericolo Effettuare sempre le connessioni allo strumento con OUTPUT disattivato Il morsetto segnato collegato allo chassis e al terminale di sicurezza di terra 21 Funzionamento In modalit A indipendente il funzionamento di entrambe le uscite identico la descrizione che segue si applica a tutt e due le uscite In modalit B e C attiva solo l uscita 2 e l uscita 1 fuori uso pertanto la descrizione valida solo per l uscita 2 Vedere la sezione Selezione della modalit Impostazione dell uscita Con l interruttore POWER alimentazione regolato su I e l uscita su off spenta la tensione di uscita ed il limite di corrente possono essere preimpostati accuratamente usando i comandi VOLTAGE tensione e CURRENT corr
22. de corriente de 0 4A Los controles de salida 1 no est n operativos y el visor est en blanco Los terminales de la salida 1 est n aislados de los de la salida 2 Recuerde que con el interruptor de salida de la salida 1 en la posici n ON el piloto de salida se sigue iluminando pero los terminales permanecen en circuito abierto Recuerde tambi n que el rango y el escalamiento del control del l mite de corriente se doblan cuando se cambia de Modo A a Modo B es decir ajustando el control a un l mite de 1 5A en el Modo A el l mite se convierte en 3A en el Modo B Para evitar posibles da os al circuito que se prueba las salidas se deben desconectar antes de que se cambie el modo y se debe ajustar el l mite de corriente al nivel adecuado antes de que se conecte la salida 27 Modo C Con el interruptor en esta posici n s lo la salida 2 est activa el rango de voltaje es 0 150V y el rango de corriente es 0 2A Los controles de la salida 1 no est n operativos y el visor est en blanco El terminal rojo de la salida 1 est aislado pero el terminal negro permanece conectado internamente al terminal negro de la salida 2 Recuerde que con el interruptor de salida de la salida 1 en la posici n ON el piloto de salida se sigue iluminando pero el terminal rojo permanece en circuito abierto Recuerde tambi n que el rango y el escalamiento del control del l mite de corriente se doblan cuando se cambia de Modo B a Modo C es de
23. e ajusta la salida de corriente con el control CURRENT y los controles VOLTAGE ajustan la tensi n m xima que se puede generar Se ilumina la l mpara CC para indicar el modo de corriente constante Salida Instant nia de Corriente Se puede ajustar el control de l mite de la corriente para limitar la salida de corriente continua a niveles de hasta 10mA Sin embargo en com n con todas las alimentaciones el ctricas de precisi n de banca se conecta una capacitancia a trav s de la salida para mantener estabilidad y repuesta buena a tensiones de ondas transitorias Esta capacitance carga hasta la tensi n de salida y un cortocircuito de la salida producir un pulso de corriente mientras la capacitancia descarga el cual es independiente del l mite preajustado de la corriente Selecci n de modo A Los tres modos de funcionamiento se seleccionan mediante el mando giratorio del panel frontal situado entre los terminales Precauci n Desactive ambas salidas antes de cambiar de modo Si el modo se cambia con cualquiera de las salidas todav a activadas el circuito as como tambi n la misma unidad podr an da arse Modo A Con el interruptor en esta posici n las salidas funcionan independientemente y est n aisladas entre s El rango de voltaje en cada salida es de 0 75V y el rango de corriente 0 2A Modo B Con el interruptor en esta posici n s lo la salida 2 est activa el rango de voltaje es de 0 75V y el rango
24. e operation and to retain the instrument in a safe condition This instrument has been designed for indoor use in a Pollution Degree 2 environment in the temperature range 5 C to 40 C 20 80 RH non condensing It may occasionally be subjected to temperatures between 5 C and 10 C without degradation of its safety Do not operate while condensation is present Use ofthis instrument in a manner not specified by these instructions may impair the safety protection provided Do not operate the instrument outside its rated supply voltages or environmental range WARNING THIS INSTRUMENT MUST BE EARTHED Any interruption of the mains earth conductor inside or outside the instrument will make the instrument dangerous Intentional interruption is prohibited The protective action must not be negated by the use of an extension cord without a protective conductor When the instrument is connected to its supply terminals may be live and opening the covers or removal of parts except those to which access can be gained by hand is likely to expose live parts The apparatus shall be disconnected from all voltage sources before it is opened for any adjustment replacement maintenance or repair Capacitors inside the power supply may still be charged even if the power supply has been disconnected from all voltage sources but will be safely discharged about 10 minutes after switching off power Any adjustment maintenance and repair of the opened in
25. efective Product or parts thereof to AMETEK in accordance with the return procedure specified below AMETEK will at its expense deliver the repaired or replaced Product or parts to the Buyer Any warranty of AMETEK will not apply if the Buyer is in default under the Purchase Order Agreement or where the Product or any part thereof is damaged by misuse accident negligence or failure to maintain the same as specified or required by AMETEK is damaged by modifications alterations or attachments thereto which are not authorized by AMETEK is installed or operated contrary to the instructions of AMETEK is opened modified or disassembled in any way without AMETEK s consent or is used in combination with items articles or materials not authorized by AMETEK The Buyer may not assert any claim that the Products are not in conformity with any warranty until the Buyer has made all payments to AMETEK provided for in the Purchase Order Agreement PRODUCT RETURN PROCEDURE 30 Request a Return Material Authorization RMA number from the repair facility must be done in the country in which it was purchased In the USA contact the AMETEK Repair Department prior to the return of the product to AMETEK for repair Telephone 800 733 5427 ext 2295 or ext 2463 toll free North America 858 450 0085 ext 2295 or ext 2463 direct Outside the United States contact the nearest Authorized Service Center ASC A full listing can be found eit
26. eisten Dieses Ger t ist f r den Betrieb in Innenr umen der Umgebungsklass 2 f r einen Temperaturbereich von 5 C bis 40 C und 20 80 relative Feuchtigkeit nicht kondensierend vorgesehen Gelegentlich kann es Temperaturen zwischen 5 und 10 C ausgesetzt sein ohne da seine Sicherheit dadurch beeintr chtigt wird Betreiben Sie das Ger t jedoch auf keinen Fall solange Kondensation vorhanden ist Ein Einsatz dieses Ger ts in einer Weise die f r diese Anlage nicht vorgesehen ist kann die vorgesehene Sicherheit beeintr chtigen Auf keinen Fall das Ger t au erhalb der angegebenen Nennversorgungsspannungen oder Umgebungsbedingungen betreiben WARNUNG DIESES GER T MUSS GEERDET WERDEN Jede Unterbrechung des Netzschutzleiters innerhalb oder au erhalb des Ger ts macht das Ger t gef hrlich Eine absichtliche Unterbrechung ist verboten Die Schutzwirkung darf durch Verwendung eines Verl ngerungskabels ohne Schutzleiter nicht aufgehoben werden Ist das Ger t an die elektrische Versorgung angeschlossen so k nnen die Klemmen unter Spannung stehen was bedeutet da beim Entfernen von Verkleidungs oder sonstigen Teilen mit Ausnahme der Teile zu denen Zugang mit der Hand m glich ist h chstwahrscheinlich spannungsf hrende Teile blo gelegt weden Vor jeglichem ffnen des Ger ts zu Nachstell Auswechsel Wartungs oder Reparaturzwecken Ger t stets von s mtlichen Spannungsquellen abklemmen Kondensatoren in der
27. ellung des Ausgangs Bei eingeschaltetem POWER Schalter Netz I und ausgeschaltetem Ausgang l t sich die Ausgangsspannung und Strombegrenzung mit Hilfe der Kn pfe VOLTAGE Spannung und CURRENT Strom genau voreinstellen Die linke Anzeige zeigt die eingestellte Spannung und die rechte den eingestellten Maximalstrom an Wenn der Ausgangsschalter eingeschaltet wird leuchtet die ON Ein Leuchte auf Jetzt wird auf der linken Anzeige die Istspannung und an der rechten Anzeige der Ist Laststrom angezeigt Konstantspannung Die Ausgangsspannung wird mittels der Grob coarse und Feindrehkn pfe fine von VOLTAGE reguliert Mit dem Knopf CURRENT Strom wird der Maximalstrom eingestellt der zur Verf gung gestellt werden kann Konstantstrom Ist der Belastungswiderstand ausreichend niedrig da bei der eingestellten Ausgangsspannung ein Strom flie en w rde der gr er w re als die eingestellte Strombegrenzung so schaltet die Stromversorgung automatisch auf konstanten Strombetrieb Der Stromausgang wird mit dem Knopf CURRENT eingestellt und die maximal generierbare Spannung mit dem Knopf VOLTAGE Die CC Leuchte leuchtet bei eingeschaltetem Konstantstrommodus auf Augenblickstromausgang Mit der Strombegrenzung kann der kontinuierliche Ausgangsstrom bis auf 10 mA begrenzt werden Wie bei allen Pr zisions Stromversorgungs Tischger ten ist der Ausgang zur Aufrechterhaltung der Stabilit t und zwecks gutem Einschwingverhal
28. ened and that connections are only made using leads fitted with fixed shroud 4mm safety plugs Make sure that the circuit to which connections are made is appropriately insulated no accessible parts of the external circuit should become hazardous live in normal or single fault condition as defined by EN61010 1 Always make connections to the instrument with the OUTPUT off The terminal marked is connected to the chassis and safety earth ground Operation The operation of both outputs is identical in Mode A independent mode the following description applies to both In Mode B and Mode C only Output 2 is active and Output 1 is disabled the description therefore only applies to Output 2 see Mode Selection section Setting Up the Output With the POWER switch on I and the output off the output voltage and current limit can be accurately preset using the VOLTAGE and CURRENT controls the left hand meter shows the set voltage and the right hand meter shows the set maximum current When the output switch is switched on the ON lamp lights the left hand meter now shows the actual voltage and the right hand meter the actual load current Constant Voltage The output voltage is adjusted using the coarse and fine VOLTAGE controls the CURRENT control sets the maximum current that can be supplied Constant Current If the load resistance is low enough such that at the output voltage set a current greater than the current limi
29. ente il misuratore di sinistra mostra la tensione impostata mentre quello di destra indica la corrente massima impostata Azionando l interruttore dell uscita si accendono gli indicatori luminosi di ON acceso il misuratore di sinistra mostra ora la tensione effettiva mentre il misuratore di destra riporta la corrente di carico effettiva Tensione costante La tensione di uscita viene regolata usando i comandi di VOLTAGE tensione approssimata e precisa il comando CURRENT permette di definire la corrente massima che si pu fornire Corrente costante Se la resistenza al carico sufficientemente bassa da far s che con la tensione di uscita impostata scorra una corrente superiore al limite impostato l alimentazione assumer automaticamente un funzionamento a corrente costante L uscita di corrente viene regolata con il comando CURRENT mentre i comandi VOLTAGE impostano la tensione massima che possibile generare L indicatore CC si accende per mostrare il funzionamento a corrente costante Uscita di corrente istantanea Il comando di limitazione di corrente pu essere impostato per limitare la corrente di uscita continua a livelli fino a 10mA Tuttavia in comune con tutti gli alimentatori da banco di precisione sull uscita collegato un condensatore che consente di mantenere stabilit ed una buona risposta ai transienti Le scariche di questo condensatore alla tensione di uscita e la cortocircuitazione dell uscita
30. from those of Output 2 Note that with the output switch of Output 1 in the ON position the Output lamp still lights but the terminals remain open circuit Note also that the range and scaling of the current limit control doubles when changing from Mode A to Mode B i e with the control set for a 1 5A limit in Mode A the limit becomes 3A in Mode B To avoid possible damage to the circuit being tested the outputs should be switched off before the mode is changed and the current limit set to the desired value before the output is switched on Mode C With the switch in this position only Output 2 is active the voltage range is 0 150V and the current range is 0 2A The controls of Output 1 are inoperative and the display is blanked The red terminal of Output 1 is isolated but the black terminal remains connected internally to the black terminal of Output 2 Note that when the output switch of Output 1 is in the ON position the Output lamp still lights but the red terminal remains open circuit Note also that the range and scaling of the voltage controls of Output 2 double when changing from Mode B to Mode C i e with the controls set for 60V in Mode B the output voltage becomes 120V in Mode C Care should therefore be taken to ensure that the outputs are switched off before the mode is changed and that the output is set to the correct voltage before it is switched on Protection The output has intrinsic short circuit protection a
31. her through your local distributor or our website www programmablepower com by clicking Support and going to the Service Centers tab When requesting an RMA have the following information ready Model number Serial number Description of the problem NOTE Unauthorized returns will not be accepted and will be returned at the shipper s expense NOTE A returned product found upon inspection by AMETEK to be in specification is subject to an evaluation fee and applicable freight charges AMETEK Programmable Power Inc 9250 Brown Deer Road San Diego CA 92121 USA Phone 858 450 0085 local direct 800 733 5427 toll free North America Fax 858 458 0267 sales programmablepower com service programmablepower com www programmablepower com
32. inte NY courant alternatif c a consulter la documentation ce manuel pour trouver la nature du danger potentiel et toute action qui doit tre prise alimentation secteur ON allum e N Attention risque de danger Veuillez Installation Tension de secteur op rationnelle Cet instrument a une plage d entr e universelle et il fonctionne sur une alimentation secteur de 115 V ou de 230 V tension nominale sans ajustement aucun V rifier que l alimentation locale satisfait aux imp ratifs d entr e c a indiqu s aux Caract ristiques techniques C ble secteur Brancher l appareil sur l alimentation secteur l aide du cordon secteur fourni S il s av re n cessaire d utiliser une fiche secteur destin e un autre type de prise murale employer un cordon secteur correctement dimensionn et homologu en l quipant de la fiche murale voulue et d un connecteur IEC60320 C13 du c t de l appareil Pour d terminer l intensit nominale minimale du cordon en fonction de l alimentation sur secteur pr vue consulter les caract ristiques de puissance nominale figurant sur le mat riel ou dans le chapitre Sp cifications AVERTISSEMENT CET APPAREIL DOIT ETRE RELI LA TERRE Toute interruption du conducteur de terre de la prise secteur l int rieur ou l ext rieur de l appareil rendra ce dernier dangereux Il est interdit d effectuer une coupure intentionnelle Ventilation A L alimentation est tr s perfo
33. ligrosas bien en estado normal o con fallo individual seg n define la norma EN 61010 1 Las conexiones al aparato deber n siempre realizarse con la salida de tensi n OUTPUT en posici n OFF Conexi n en Serie o en Paralelo a Otras Salidas A A 28 Las salidas del suministro de fuerza son completamente flotantes y pueden emplearse en serie con otras unidades de suministro de fuerza para generar altos voltajes de CC de hasta 300V CC Precauci n De acuerdo con la norma EN 61010 1 los voltajes por encima de 70 V de corriente continua se consideran tensi n peligrosa por lo que deber adoptarse especial cuidado al utilizar la fuente de alimentaci n por encima de estos valores La tensi n m xima admisible entre cualquier borne y la tierra f sica gt es de 300 VCC la tensi n m xima admisible entre uno u otro de los bornes de una salida y cualquier borne de otra salida del mismo suministro tambi n es de 300 VCC AVISO Todas las conexiones a los terminales se deben realizar con la salida desconectada en todas las unidades Se debe observar que la unidad s lo puede suministrar corriente pero no puede sumirla consecuentemente las unidades no pueden conectarse en serie de modo antif sico La unidad puede conectarse en paralelo a otras para producir una corriente superior Cuando varias unidades est n conectadas en paralelo el voltaje de salida ser igual al de la unidad con el reglaje voltaje de salida superior hast
34. m mais la borne rouge reste en circuit ouvert Noter galement que la gamme et la mise l chelle des commandes de tension de la sortie 2 doublent de valeur lorsqu on passe du mode B au mode C c d que lorsque les commandes sont r gl es 60 V en mode B la tension de sortie passe 120 V en mode C Il faut donc veiller d sactiver les sorties avant de changer de mode et r gler la sortie la tension correcte avant de l activer Protection La sortie dispose d une protection intrins que contre les courts circuits et elle est prot g e contre la tension inverse par une diode le courant inverse continu ne doit pas d passer 3 A bien qu il soit possible que l intensit des transitoires soit nettement sup rieure La sortie est prot g e contre des tensions directes appliqu es en externe jusqu 85 V Modes A et B ou jusqu 170 V Mode C Connexion la charge A A La charge devra tre connect e aux bornes OUTPUT positive rouge et n gative noire Les deux sont enti rement flottantes et l une ou l autre peuvent tre connect es la masse Avertissement Les tensions sup rieures 70 Vcc sont dangereuses sous tension selon la norme EN 61010 1 et le plus grand soin doit tre pris lors de l utilisation de tensions sup rieures ce niveau Il est vivement recommand de n effectuer de connexions qu l aide de fils munis de bouchons de s curit protection fixe de 4 mm S assurer que
35. m Umschalten von Modus A auf Modus B verdoppeln d h erfolgt die Einstellung auf eine 1 5 A Begrenzung in ModusA so betr gt die Begrenzung in Modus B 3A Um die M glichkeit eines Schadens am zu pr fenden Stromkreis zu vermeiden sind vor dem Umschalten die Ausg nge auszuschalten und die Strombegrenzung ist auf den gew nschten Wert einzustellen bevor der Ausgang wieder eingeschaltet wird Modus C Befindet sich der Schalter in dieser Stellung so ist nur Ausgang 2 aktiv Der Spannungsbereich betr gt 0 150 V und der Strombereich 0 2 A Die Bedienungselemente des Ausgangs 1 befinden sich au er Betrieb und die Anzeige ist ausgeblendet Die rote Klemme von Ausgang 1 ist getrennt doch bleibt die schwarze Klemme intern mit der schwarzen Klemme von Ausgang 2 verbunden Beachten Sie bitte da wenn sich der Ausgangsschalter von Ausgang 1 in der EIN Stellung befindet die Ausgangsleuchte nach wie vor aufleuchtet die rote Klemme jedoch nach wie vor einen offenen Stromkreis bildet Beachten Sie bitte auch da sich Umfang und die Skalierung der Spannungs Bedienungselemente von Ausgang 2 beim Umschalten von Modus B auf Modus C verdoppeln d h da wenn bei Modus B eine Einstellung von 60 V erfolgt im Modus C die Ausgangsspannung 120 V betr gt Aus diesem Grund ist darauf zu achten da vor dem Umschalten des Modus die Ausg nge ausgeschaltet werden und da der Ausgang vor dem Einschalten auf die richtige Spannung eingestellt wird
36. n elementos bajo tensi n y la abertura de tapas o el retiro de piezas salvo las accesibles por la mano pueden dejar expuestos a elementos bajo tensi n Si se tuviera que efectuar alguna operaci n de ajuste cambio mantenimiento o reparaci n es necesario desconectar al instrumento de todas las fuentes de tensi n Los capacitores dentro del aparato pueden permanecer cargados a n cuando las fuentes de tensi n hayan sido desconectadas pero quedar n seguramente descargadas a 10 minutos de haber desconectado la corriente Todo ajuste mantenimiento o reparaci n del instrumento abierto bajo tensi n debe ser evitado en lo posible pero si fuera ineludible estos trabajos deben ser realizados exclusivamente por un personal cualificado consciente del riesgo que implican Si el instrumento fuera claramente defectuoso hubiera sido sometido a un da o mec nico a humedad excesiva o a corrosi n qu mica su protecci n de seguridad puede fallar y el aparato debe sacarse de uso y devolverse para comprobaci n y reparaci n Asegurar que s lo se empleen fusibles de la clasificaci n y tipo especificados para todo recambio Est prohibido utilizar fusibles improvisados as como el corto circuito de portafusibles El instrumento no debe humedecerse al ser limpiado Los s mbolos a continuaci n son empleados en el instrumento y en este manual Terminal a tierra Corriente cont nua CC alimentaci n principal ON MN corriente alterna ca
37. nd is protected from reverse voltages by a diode the continuous reverse current must not exceed 3 Amps although transients can be much higher The output is protected against externally applied forward voltages of up to 85V Modes A and B or 170V Mode C Connection to the Load A A The load should be connected to the positive red and negative black OUTPUT terminals Both are fully floating and either can be connected to ground Warning Voltages above 70Vdc are hazardous live according to EN 61010 1 and great care must be taken when using the power supply at voltages above this level It is highly recommended that connections are only made using leads fitted with fixed shroud 4mm safety plugs Make sure that the circuit to which connections are made is appropriately insulated no accessible parts of the external circuit should become hazardous live in normal or single fault condition as defined by EN61010 1 Always make connections to the instrument with the OUTPUT off Series or Parallel Connection with Other Outputs A A The outputs of the power supply are fully floating and may be used in series with other power supply units to generate high DC voltages up to 300V DC Warning Voltages above 70Vdc are hazardous live according to EN 61010 1 and great care must be taken when using the power supply at voltages above this level L The maximum permissible voltage between any terminal and earth ground is 300VDC the ma
38. ng Spannungen ber 70 VDC sind nach EN 61010 1 lebensgef hrlich Daher ist bei Netzteilspannungen ber diesem Wert u erst vorsichtig vorzugehen Die maximal zul ssige Spannung zwischen einer beliebigen Klemme und Erde gt betr gt 300 V Gleichspannung Die maximal zul ssige Spannung zwischen einer der beiden Klemmen eines Ausgangs und einer beliebigen Klemme eines anderen Ausgangs desselben Ger ts betr gt ebenfalls 300 V Gleichspannung S mtliche Anschl sse an die Klemmen m ssen bei ausgeschaltetem Ausgang aller Einheiten erfolgen Zu beachten ist dabei daR das Ger t ausschlieRlich stromliefernd nicht aber stromziehend arbeiten kann und da die Ger te daher nicht gegenphasig in Reihe geschaltet werden k nnen Das Ger t kann zur Erzeugung einer h heren Stromabgabe mit anderen Ger ten parallel zu diesen geschaltet werden Wenn mehrere Ger te parallel geschaltet werden entspricht die Ausgangsspannung der Ausgangsspannung des Ger ts bei dem der Einstellwert f r die Ausgangsspannung am h chsten ist bis die Stromaufnahme den bei diesem Ger t eingestellten Grenzwert berschreitet woraufhin der Ausgang auf die zweilh chste Einstellung abf llt und so weiter Im Konstantstrombetrieb k nnen Ger te parallel geschaltet werden wodurch sich eine Stromabgabe erreichen l t die der Summe der Einstellwerte f r die Strombegrenzung entspricht Wartung Die Hersteller bzw deren Vertretungen im Ausland bieten die Reparatur v
39. on Ger ten an bei denen eine St rung aufgetreten ist Wenn der Eigent mer die Wartungsarbeiten selbst durchf hren m chte hat er daf r Sorge zu tragen da diese Arbeiten ausschlie lich von entsprechend qualifiziertem Personal und gem Wartungshandbuch ausgef hrt werden das direkt von den Herstellern oder deren Vertretungen im Ausland bezogen werden kann Sicherungen Korrekter Sicherungstyp Tr ge Hochleistungssicherung T 10 Amp 250 V 5 x 20 mm Beachten Sie bitte da die Hauptfunktion der Sicherung der Schutz von Personen sowie Ger teteilen ist bzw die Begrenzung solcher Sch den im Falle von St rungen an den Schaltger ten Brennt eine Sicherung durch so ist es h chst wahrscheinlich da auch ihr Ersatz durchbrennt weil eine St rung im Ger t vorliegt In einem solchen Falle ist es erforderlich da das Ger t vom Hersteller repariert wird Achten Sie darauf da nur Sicherungen der vorgeschriebenen Stromst rke und des angegebenen Typs als Ersatzsicherungen verwendet werden Die Verwendung von Behelfssicherungen und das Kurzschlie en von Sicherungshaltern ist verboten Zum Auswechseln einer Sicherung zuerst das Ger t von seiner Wechselstromversorgung trennen Dann die 6 Befestigungsschrauben des Geh uses entfernen und danach das Geh use abheben Sicherung durch eine korrekte Ersatzsicherung ersetzen und Geh use wieder montieren Reinigung Falls die Stromversorgung der Reinigung bedarf einen mit Wasser ode
40. or lo tanto es importante que la ventilaci n no est restringida si se quiere mantener el rendimiento y la seguridad Conexiones Todas las conexiones se efectuan desde el panel delantero La carga se ha de conectar a los terminales positivo rojo y negativo negro marcados OUTPUT Salida Conecte a una o ambas salidas seg n corresponda al modo seleccionado ver el apartado Operaci n Precauci n De acuerdo con la norma EN 61010 1 los voltajes por encima de 70 V de corriente continua se consideran tensi n peligrosa por lo que deber adoptarse especial cuidado al utilizar la fuente de alimentaci n por encima de estos valores Los bornes de seguridad universales empleados para la salida de tensi n cumplen con los requisitos de aislamiento reforzado para voltajes superiores a 250 V CC puesto que la distancia y el espacio hasta los contactos es superior a 2 5 mm incluso con el borne completamente abierto Sin embargo se recomienda encarecidamente apretar completamente los bornes como medida habitual y realizar las conexiones nicamente con cables que contengan patillas de seguridad de 4 mm con protector fijo Aseg rese de que el circuito en el que se realicen las conexiones est correctamente aislado ninguna parte accesible del circuito externo deber presentar tensiones el ctricas peligrosas bien en estado normal o con fallo individual seg n define la norma EN 61010 1 Las conexiones al aparato deber n siempre realizarse
41. pleen s lo fusibles de la clasificaci n y del tipo especificado para todo recambio Est prohibido utilizar fusibles improvizados as como el cortocircuito del portafusibles Para cambiar un fusible primero desconectar el instrument de la alimentaci n el ctrica de CA Quitar los 6 tornillos que sujetan la tapa y alzar la tapa Reemplazar el fusible con uno del tipo correcto y volver a colocar la tapa Limpieza Si la unidad de suministro de fuerza necesita ser limpiada utilizar un pa o brevemente humedecido en agua o en un detergente suave La ventana de visualizaci n debe lustrarse con un pa o suave y seco ADVERTENCIA PARA EVITAR CHOQUES ELECTRICOS O DA AR A LA UNIDAD DE SUMINISTRO DE FUERZA NUNCA DEJE ENTRAR AGUA AL ENVASE PARA EVITAR QUE EL ENVASE O LA VENTANA DE VISUALIZACION SEAN DA ADOS NUNCA LIMPIE CON SOLVENTES 29 Warranty Information Product Family XPH Series 75V 2A Dual DC Power Supply Warranty Period Three Years WARRANTY TERMS AMETEK Programmable Power Inc AMETEK provides this written warranty covering the Product stated above and if the Buyer discovers and notifies AMETEK in writing of any defect in material or workmanship within the applicable warranty period stated above then AMETEK may at its option repair or replace the Product or issue a credit note for the defective Product or provide the Buyer with replacement parts for the Product The Buyer will at its expense return the d
42. r einem milden Detergens angefeuchteten Lappen benutzen Anzeigefenster mit einem weichen trockenen Lappen polieren WARNUNG ZUR VERMEIDUNG EINES ELEKTRISCHEN SCHLAGS BZW BESCH DIGUNG DER STROMVERSORGUNGSEINHEIT DAF R SORGEN DASS KEIN WASSER INS GEH USE EINDRINGT UM SCHADEN AM GEH USE BZW AM ANZEIGEFENSTER ZU VERMEIDEN KEINE L SUNGSMITTEL ZUR REINIGUNG VERWENDEN 19 20 Sicurezza Questo strumento appartiene alla Categoria di Sicurezza 1 secondo la classifica IEC ed stato progettato in modo da soddisfare i criteri EN61010 1 requisiti di Sicurezza per Apparecchiature di misura controllo e per uso in laboratorio uno strumento di Categoria d installazione Il ed inteso per il funzionamento con un alimentazione normale monofase Questo strumento ha superato le prove previste da EN61010 1 e viene fornito in uno stato di sicurezza normale Questo manuale contiene informazioni e avvertenze che devono essere seguite per assicurare un funzionamento sicuro e mantenere lo strumento in condizioni di sicurezza Questo strumento progettato per uso all interno e in un ambiente d inquinamento Grado 2 entro la gamma di temperatura da 5 C a 40C con umidit relativa non condensante di 20 80 Pu occasionalmente essere assoggettato a temperature fra 5 C e 10 C senza comprometterne la sicurezza Non usare in presenza di condensazione L uso dello strumento in maniera non conforme a quanto specificato in ques
43. ra si guasti uno dei propri dispositivi di commutazione Se si guasta un fusibile sar pertanto molto probabile che salti anche il fusibile di ricambio in quanto si verificato un malfunzionamento nell alimentazione In queste circostanze lo strumento deve essere restituito al produttore per la riparazione Per la sostituzione accertarsi che vengano usati fusibili del tipo e della corrente nominale specificati proibito usare fusibili di ripiego o cortocircuitare i portafusibili Per sostituire un fusibile scollegare prima lo strumento dall alimentazione CA Rimuovere le 6 viti di fissaggio del coperchio e sollevare quest ultimo Sostituire il fusibile con un fusibile di tipo corretto e riporre il coperchio Pulizia 24 Se si deve pulire il dispositivo di alimentazione usare uno strofinaccio appena bagnato con acqua o con un detergente neutro Pulire la finestrella di visualizzazione con un panno asciutto e morbido ATTENZIONE PER EVITARE SCOSSE ELETTRICHE ED EVENTUALI DANNI AL DISPOSITIVO DI ALIMENTAZIONE NON PERMETTERE MAI ALL ACQUA DI ENTRARE ALL INTERNO DELL ALLOGGIAMENTO PER EVITARE DANNI ALL ALLOGGIAMENTO E ALLA FINESTRELLA DI VISUALIZZAZIONE NON PULIRE MAI CON SOLVENTI Seguridad Este es un instrumento de Clase de Seguridad seg n la clasificaci n del IEC y ha sido dise ado para cumplir con los requisitos del EN61010 1 Requisitos de Seguridad para Equipos El ctricos para la Medici n Control y Uso en Labor
44. rce de tension ventuelle de l appareil avant de l ouvrir pour effectuer des r glages remplacements travaux d entretien ou de r parations Les condensateurs qui se trouvent dans le bloc d alimentation risquent de rester charg s m me si le bloc d alimentation a t d connect de toutes les sources de tension mais ils se d chargeront en toute s curit environ 10 minutes apr s extinction de l alimentation Eviter dans la mesure du possible d effectuer des r glages travaux de r parations ou d entretien lorsque l instrument ouvert est branch une source d alimentation mais si c est absolument n cessaire seul un technicien comp tent au courant des risques encourus doit effectuer ce genre de travaux S il est vident que l instrument est d fectueux qu il a t soumis des d g ts m caniques une humidit excessive ou une corrosion chimique la protection de s curit sera amoindrie et il faut retirer l appareil afin qu il ne soit pas utilis et le renvoyer en vue de v rifications et de r parations Uniquement remplacer les fusibles par des fusibles d intensit nominale requise et de type sp cifi Il est interdit d utiliser des fusibles bricol s et de court circuiter des porte fusibles Eviter de mouiller l instrument lors de son nettoyage Les symboles suivants se trouvent sur l instrument ainsi que dans ce manuel Borne de terre masse courant continu C C alimentation secteur OFF te
45. requise et de type sp cifi Il est interdit d utiliser des fusibles bricol s et de court circuiter des porte fusibles Pour remplacer un fusible commencer par d brancher l instrument de l alimentation c a Enlever les 6 vis d immobilisation du couvercle puis enlever le couvercle Remplacer le fusible par un autre de type correct puis remettre le couvercle Nettoyage 14 S il faut nettoyer le bloc d alimentation utiliser un chiffon l g rement imbib d eau ou d un d tergent doux Nettoyer le cadran d affichage au moyen d un chiffon sec et doux AVERTISSEMENT EMPECHER TOUTE INTRODUCTION D EAU DANS LE BOITIER AFIN D EVITER TOUT CHOC ELECTRIQUE ET DEGATS AU BLOC D ALIMENTATION NE JAMAIS UTILISER DE DISSOLVANTS POUR NETTOYER LE BLOC AFIN D EVITER D ENDOMMAGER LE BOITIER OU LE CADRAN D AFFICHAGE Sicherheit Dieses Ger t wurde nach der Sicherheitsklasse Schutzart der IEC Klassifikation und gem den europ ischen Vorschriften EN61010 1 Sicherheitsvorschriften f r elektrische Me Steuer Regel und Laboranlagen entwickelt Es handelt sich um ein Ger t der Installationskategorie II das f r den Betrieb von einer normalen einphasigen Versorgung vorgesehen ist Das Ger t wurde gem den Vorschriften EN61010 1 gepr ft und wurde in sicherem Zustand geliefert Die vorliegende Anleitung enth lt vom Benutzer zu beachtende Informationen und Warnungen die den sicheren Betrieb und den sicheren Zustand des Ger tes gew hrl
46. rmante mais elle peut toutefois g n rer beaucoup de chaleur puissance maximale L alimentation a besoin d un refroidissement par convection uniquement et il est donc important que la ventilation ne soit jamais r duite afin d assurer une bonne performance et s curit Connexions Toutes les connexions sont effectu es au panneau avant La charge doit tre reli e aux bornes positive rouge et n gative noire marqu es OUTPUT Sortie Relier une sortie ou aux deux selon les besoins pour le mode s lectionn voir la section Fonctionnement Avertissement Les tensions sup rieures 70 Vcc sont dangereuses sous tension selon la norme EN 61010 1 et le plus grand soin doit tre pris lors de l utilisation de tensions sup rieures ce niveau Les bornes d attache de s curit universelles utilis es pour la sortie satisfont aux conditions d isolation renforc e pour des tensions sup rieures 250 Vcc car les lignes de fuite et la distance d isolement jusqu aux contacts de la borne sont gt 2 5 mm m me lorsque la borne est totalement ouverte Toutefois il est vivement recommand de serrer les bornes d attache fond et de n effectuer les connexions qu l aide de fils munis de bouchons de s curit protection fixe de 4 mm S assurer que le circuit sur lequel sont effectu es les connexions est correctement isol aucune des pi ces accessibles du circuit externe ne devrait tre dangereuse lorsque l appareil es
47. s de haute intensit Lorsque plusieurs blocs sont reli s en parall le la tension de sortie doit tre gale celle du bloc de r glage de tension de sortie le plus lev jusqu ce que le courant consomm d passe le r glage de limite de courant auquel cas la sortie descend celle du r glage le plus haut suivant etc En mode de courant constant les blocs peuvent tre reli s en parall le afin de donner un courant gal la somme des r glages de limite de courant 13 Maintenance Le Constructeur ou ses agents l tranger r pareront tout bloc qui tombe en panne Si le propri taire de l appareil d cide d effectuer lui m me la maintenance ceci doit uniquement tre effectu par un personnel sp cialis qui doit se r f rer au manuel d entretien que l on peut se procurer directement aupr s du Constructeur ou de ses agents l tranger Fusible Type de fusible correct 10 250 V HBC temporis T 5 x 20 mm Il faut noter que l objet principal de ce fusible est de rendre l instrument non dangereux et de limiter les d g ts en cas de panne d un des dispositifs de commutation En cas de panne d un fusible il est tr s probable que le fusible de rechange sautera galement tant donn que l alimentation est probablement d fectueuse lorsque c est le cas il faudra renvoyer l instrument chez le constructeur en vue de r parations Uniquement remplacer les fusibles par des fusibles d intensit nominale
48. sed which is fitted with the required wall plug and an IEC60320 C13 connector for the instrument end To determine the minimum current rating of the lead set for the intended AC supply refer to the power rating information on the eguipment or in the Specification WARNING THIS INSTRUMENT MUST BE EARTHED Any interruption of the mains earth conductor inside or outside the instrument will make the instrument dangerous Intentional interruption is prohibited Ventilation The power supply is very efficient but nevertheless can generate significant heat at full power The supply relies on convection cooling only and itis therefore important that ventilation is never restricted if performance and safety are to be maintained Connections All connections are made from the front panel The load should be connected to the positive red and negative black terminals marked OUTPUT Connect to one or both outputs as appropriate for the selected Mode see Operation section Warning Voltages above 70Vdc are hazardous live according to EN 61010 1 and great care must be taken when using the power supply at voltages above this level The universal safety binding posts used for the output meet the reguirements for reinforced insulation for voltages up to 250Vdc because creepage and clearance to the terminal contacts is gt 2 5mm even with the binding post fully open However it is highly recommended that the binding posts are usually fully tight
49. strument under voltage shall be avoided as far as possible and if inevitable shall be carried out only by a skilled person who is aware of the hazard involved If the instrument is clearly defective has been subject to mechanical damage excessive moisture or chemical corrosion the safety protection may be impaired and the apparatus should be withdrawn from use and returned for checking and repair Make sure that only fuses with the required rated current and of the specified type are used for replacement The use of makeshift fuses and the short circuiting of fuse holders is prohibited Do not wetthe instrument when cleaning it The following symbols are used on the instrument and in this manual Earth ground terminal mains supply OFF mains supply ON alternating current ac I O direct current dc Caution risk of danger Refer to the documentation this manual to find out the nature of the potential hazard and any actions which have to be taken gt Installation Mains Operating Voltage This instrument has a universal input range and will operate from a nominal 115V or 230V mains supply without adjustment Check that the local supply meets the AC Input reguirement given in the Specification Mains Lead Connect the instrument to the AC supply using the mains lead provided Should a mains plug be reguired for a different mains outlet socket a suitably rated and approved mains lead set should be u
50. subito un danno meccanico un eccesso di umidit o corrosione a mezzo di agenti chimici la sicurezza potrebbe essere stata compromessa e lo strumento deve essere ritirato dall uso e rimandato indietro per le prove e le riparazioni del caso Assicurarsi di usare solo fusibili della portata giusta e del tipo corretto durante eventuali sostituzioni Sono proibiti sia l uso di fusibili improvvisati che il corto circuito deliberato dei portafusibili Evitare di bagnare lo strumento quando lo si pulisce Sullo strumento e in questo manuale si fa uso dei seguenti simboli Terminale di terra Corrente Continua alimentazione ON accesa MY Corrente Alternata O alimentazione OFF spenta Attenzione pericolo Consultare il presente manuale per individuare la tipologia del rischio potenziale e gli interventi da effettuare Installazione Tensione d esercizio Questo strumento dotato di un entrata universale e funziona con un alimentazione a 115V o 230V senza regolazione Controllare che la rete locale soddisfi i requisiti d entrata indicati nella specifica Cavo d Alimentazione Collegare lo strumento all alimentazione di rete in corrente alternata utilizzando il cavo fornito Se dovesse essere necessaria una spina di alimentazione diversa utilizzare un set completo della spina necessaria e di un connettore tipo IEC60320 C13 adeguatamente dimensionati e omologati Per determinare la corrente minima nominale del set cavo necess
51. t setting would flow the power supply will automatically move into constant current operation The current output is adjusted by the CURRENT control and the VOLTAGE controls set the maximum voltage that can be generated The CC lamp lights to show constant current mode Instantaneous Current Output The current limit control can be set to limit the continuous output current to levels down to 10mA However in common with all precision bench power supplies a capacitor is connected across the output to maintain stability and good transient response This capacitor charges to the output voltage and short circuiting of the output will produce a current pulse as the capacitor discharges which is independent of the current limit setting Mode Selection A The three operating modes are selected by the front panel rotary switch situated between the terminals Caution Turn both outputs off before changing mode Possible damage to the circuit being powered and to the unit itself may occur if the mode is switched with either output still on Mode A With the switch in this position the outputs operate independently and are isolated from one another The voltage range on each output is 0 75V and the current range 0 2A Mode B With the switch in this position only Output 2 is active the voltage range is 0 75V and the current range is 0 4A The controls of Output 1 are inoperative and the display is blanked The terminals of Output 1 are isolated
52. t sous tension dans des conditions normales ou lorsqu une seule faute est d tect e conform ment la norme EN61010 1 OUTPUT sortie doit toujours tre hors tension lors de la connexion l instrument La borne d sign e est reli e au ch ssis et la terre de protection 11 Fonctionnement Le fonctionnement des deux sorties est identigue en mode A mode independant la description suivante s applique aux deux En mode B et en mode C seule la sortie 2 est active et la sortie 1 est d sactiv e la description s applique donc uniquement la sortie 2 voir la section S lection de mode R glage de la sortie Linterrupteur POWER alimentation sur 1 et la sortie teinte il est possible de r gler avec pr cision la limite de tension et de courant de sortie au moyen des commandes VOLTAGE Tension et CURRENT Courant l appareil de mesure gauche indique la tension r gl e et l appareil droit le courant maximum r gl Lorsque le commutateur de sortie est sur marche le t moin ON Marche s allume l appareil de mesure gauche indique alors la tension v ritable et l appareil droit le courant de charge v ritable Tension constante Les commandes VOLTAGE de r glage grossier et de pr cision permettent d ajuster la tension de sortie la commande CURRENT r gle le courant maximum qui peut tre fourni Courant constant Si la r sistance de charge est suffisamment basse qu un courant sup rieur au r
53. tandards for safety and EMC including harmonics emissions All outputs are intrinsically short circuit proof and are protected against external voltages and reverse currents OUTPUTS Voltage Range Current Range Output Voltage Setting Output Current Setting Operating Mode Output Switch Output Terminals Output Protection Load Regulation Line Regulation Ripple 8 Noise 20MHz bandwidth Transient Response Temperature Coefficient Status Indication Specification OV to 75V minimum ModesA and B OV to 150V minimum Mode C OA to 2A minimum Modes A and C OA to 4A minimum Mode B By coarse and fine controls By single logarithmic control Constant voltage or constant current with automatic cross over Electronic Preset voltage and current displayed when off Universal 4mm safety binding posts on 19mm 0 75 spacing Output will withstand forward voltage of up to 85V Modes A and B or 170V Mode C Reverse protection by diode clamp for reverse currents up to 3A lt 0 01 of maximum output for a 90 load change Modes A 4 B lt 0 1 of maximum output for a 90 load change Mode C lt 0 01 of maximum output for a 10 line change Typically lt 2mVrms lt 15mV pk pk constant voltage mode lt 200us to within 50mV of set level for a 5 to 95 load change Mode A Typically lt 100ppm C Output on lamp Constant current mode lamp OPERATING MODES Mode Selection Mode
54. te di corrente deve essere impostato sul valore voluto prima di riaccendere l uscita Modalit C Con il commutatore in questa posizione attiva solo l uscita 2 La tensione va da 0 a 150V e la corrente da 0 a 2A controlli dell uscita 1 sono fuori uso e la visualizzazione in bianco II morsetto rosso dell uscita 1 isolato ma il morsetto nero rimane collegato internamente al morsetto nero dell uscita 2 Si voglia notare che con l interruttore dell uscita 1 acceso ON l indicatore d uscita si accende ma il morsetto rosso rimane in circuito aperto Si noti anche che l escursione e la scala dei controlli di tensione dell uscita 2 raddoppiano quando si cambia dalla modalit B alla C vale a dire che se i controlli sono impostati a 60V in modalit B la tensione d uscita diviene 120V in modalit C Si deve pertanto aver cura di assicurarsi che le uscite siano spente prima di cambiare la modalit e che l uscita sia impostata alla tensione giusta prima di riaccendere Protezione L uscita dotata di protezione da cortocircuito intrinseca ed protetta dalle tensioni inverse a mezzo di un diodo la corrente inversa continua non deve superare 3 Amp sebbene i transienti possano essere molto pi alti L uscita protetta contro tensioni dirette applicate dall esterno fino a 85V modalit A e B e fino a 170V modalit C Collegamento del carico A A Il carico deve essere connesso ai terminali d OUTPUT positivo rosso
55. te istruzioni potrebbe pregiudicare la protezione di cui dotato Non usare lo strumento per misurare tensioni al di sopra dei valori nominali o in condizioni ambientali al di fuori di quelle specificate ATTENZIONE QUESTO STRUMENTO DEVE ESSERE COLLEGATO A TERRA Una qualsiasi interruzione sia interna che esterna del collegamento a terra rende pericoloso questo strumento E proibito interrompere questo collegamento deliberatamente L azione protettiva non deve essere negata dall uso di una prolunga priva conduttore di protezione Quando lo strumento collegato all alimentazione alcuni morsetti sono sotto tensione e l apertura dei coperchi o la rimozione di parti eccetto quei componenti accessibili senza l uso di attrezzi pu lasciare scoperti i morsetti sotto tensione Prima di aprirla per eseguire regolazioni manutenzione o riparazioni l apparecchiatura deve essere staccata da tutte le sorgenti di tensione condensatori collegati all alimentazione interna possono essere carichi anche dopo aver staccato l alimentazione ma si scaricano in circa 10 minuti dopo aver staccato la corrente Per quanto possibile si consiglia di evitare qualsiasi operazione di regolazione e riparazione quando lo strumento sotto tensione e qualora fosse inevitabile dette operazioni devono essere eseguite da una persona specializzata in materia che sia pienamente conscia del pericolo presente Quando sia chiaro che lo strumento difettoso o che ha
56. ten mit einem Kondensator versehen Der Kondensator wird bis zur H he der Ausgangsspannung aufgeladen Ein Kurzschlie en des Ausgangs bewirkt beim Entladen des Kondensators einen Stromimpuls der von der Strombegrenzungseinstellung unabh ngig erfolgt Moduswahl A Die drei Betrieosmodi werden mit Hilfe des zwischen den Klemmen befindlichen Drehschalters an der Fronttafel gew hlt Vorsicht Vor dem Umschalten auf einen anderen Modus beide Ausg nge abschalten Wird umgeschaltet solange einer der Ausg nge noch eingeschaltet ist kann Schaden an dem versorgten Stromkreis und am Ger t selbst angerichtet werden Modus A Befindet sich der Schalter in dieser Stellung sind die Ausg nge voneinander getrennt und arbeiten unabh ngig voneinander Der Spannungsbereich eines jeden Ausgangs betr gt 0 75 V und der Strombereich 0 2 A Modus B Befindet sich der Schalter in dieser Stellung ist nur Ausgang 2 aktiv Der Spannungsbereich betr gt dann 0 75 V und der Strombereich 0 4A Die Bedienungselemente f r Ausgang 1 sind dann au er Betrieb gesetzt und die Anzeige ist ausgeblendet Die Klemmen von Ausgang 1 sind von denen des Ausgangs 2 getrennt Beachten Sie bitte da solange sich der Ausgangsschalter von Ausgang 1 in EIN Stellung befindet die Ausgangsleuchte aufleuchtet die Klemmen jedoch nach wie vor einen offenen Stromkreis bilden 17 Beachten Sie bitte auch da sich Umfang und die Skalierung der Strombegrenzung bei
57. tre La plage de tension chaque sortie est de 0 75 V et la plage d intensit 0 2 A Mode B Le commutateur dans cette position seule la sortie 2 est active la plage de tension est de 0 75 V et la plage d intensit 0 4 A Les commandes de la sortie 1 sont inop rationnelles et l affichage est occult Les bornes de la sortie 1 sont isol es de celles de la sortie 2 Noter que lorsque la sortie 1 du commutateur de sortie est sur ON Marche le t moin de sortie est toujours allum mais la borne reste en circuit ouvert Noter galement que la gamme et la mise l chelle de la commande de limite de courant doublent de valeur lorsqu on passe du mode A au mode B c d que lorsque la commande est r gl e une limite de 1 5 A en mode A la limite passe 3 A en mode B Pour viter d endommager le circuit soumis aux essais il est recommand de d sactiver les sorties avant de changer de mode et de r gler la limite de courant la valeur d sir e avant d activer la sortie Mode C Le commutateur dans cette position seule la sortie 2 est active la plage de tension est de 0 150 V et la plage d intensit 0 2 A Les commandes de la sortie 1 sont inop rationnelles et l affichage est occult La borne rouge de la sortie 1 est isol e mais la borne noire reste connect e en interne la borne noire de la sortie 2 Noter que lorsque la sortie 1 du commutateur de sortie est sur ON Marche le t moin de sortie est toujours allu
58. ung von 115 oder 230 V betrieben werden Stellen Sie sicher da die Versorgung am Ort den in der Spezifikation aufgef hrten Eingangsanforderungen entspricht Netzkabel SchlieRen Sie das Ger t unter Verwendung des mitgelieferten Netzkabels an die Wechselspannungsversorgung an Falls ein Netzstecker f r eine unterschiedliche Netzsteckdose erforderlich ist muss ein geeigneter und zugelassener Netzkabelsatz verwendet werden der mit dem geeigneten Wandstecker und einem IEC60320 C13 Stecker f r das Ger teende versehen ist Zur Bestimmung der Mindest Nennstromst rke des Kabelsatzes f r die beabsichtigte Wechselspannungsversorgung sind die Informationen zu Leistungswerten auf dem Ger t bzw in seiner Spezifikation hinzuzuziehen ACHTUNG DIESES GER T MUSS GEERDET SEIN Jegliche Unterbrechung der Netzerde ob im Innern oder auRerhalb des Ger ts macht das Ger t zur Gefahrenguelle Eine absichtliche Unterbrechung ist verboten Ventilation 16 Obwohl die Stromversorgung uBerst effizient arbeitet kann sie bei voller Leistung ein betr chtliches Ma an W rme erzeugen Die K hlung der Stromversorgung erfolgt ausschlie lich durch Konvektion weshalb es wichtig ist da die Ventilation niemals eingeschr nkt wird wenn Leistung und Sicherheit aufrecht erhalten werden sollen Anschlusse S mtliche Anschl sse erfolgen von der Fronttafel aus Der Verbraucher it an die positive rote und negative schwarze Klemme mit der Bezeichnung
59. ximum permissible voltage between either terminal of one output and any terminal of another output on the same supply is also 300VDC All connections to the terminals must be made with the output switched off on all units It should be noted that the unit can only source current and cannot sink it thus units cannot be series connected in anti phase The unit can be connected in parallel with others to produce higher currents Where several units are connected in parallel the output voltage will be equal to that of the unit with the highest output voltage setting until the current drawn exceeds its current limit setting upon which the output will fall to that of the next highest setting and so on In constant current mode units can be connected in parallel to provide a current equal to the sum of the current limit settings Maintenance The Manufacturers or their agents overseas will provide repair for any unit developing a fault Where owner wish to undertake their own maintenance work this should only be done by skilled personnel in conjunction with the service manual which may be purchased directly from the Manufacturers or their agents overseas Fuse The correct fuse type is 10 Amp 250V HBC time lag T 5 x 20mm Note that the main function of the fuse is to make the instrument safe and limit damage in the event of failure of one ofthe switching devices If a fuse fails it is therefore very likely that the replacement will also blow
Download Pdf Manuals
Related Search
Related Contents
Je suis voyageur, Je vais à l`école, C`est mon livret scolaire. Système hydraulique de mise à niveau à 4 vérins 取扱説明書 Hotte aspirante Cooker Hood Campana extractora Exaustor Keston K50 Installation Manual Stoves S7-E700MF Sweex Neoprene Netbook Sleeve Beige / Brown 12.1" `量。野 BS-50ー~ 取扱説明書 Activités de pleine nature et pastoralisme Nos Nouvelles Copyright © All rights reserved.