Home
2 installation
Contents
1. 4 PART 3 DISPLAY PANEL 5 E lo 5 3 2 MEN U 5 3 3 EDIT STATIC COLOUR 6 3 4 ACTIVATING 5 6 3 5 RUN MODE ito my HERREN 6 512 3 6 EE 7 7 3 8 SPECIAL 7 3 9 4 CTIVATE THE PASSWORD 8 3 10 BALANCE PARAMETERS AND CORRECTION MENU DISPLAY 8 PART 4 USING A 512 CONTROLLER 9 4 1 BASICADDRESSINGL 9 9 13 PART 5S APPENDIX 13 TIGHT RESEARCH 1 PRODUCT GENERAL 1 1 TECHNICAL SPECIFICATIONS LED MODULE LED MODULE Voltage Rated Power 100 240V 50 60Hz 16W Model 12W LED 1xtri RGBW Environment Temperature Cooling 20 C 40 C Direct air convection Dimensions 212 x 120 x 80mm Weight 1 01Kg TIGHT RESEARCH 1 2 SAFETY WARNING IMPORTANT ALWAYS READ THE USER MANUAL BEFORE OPERATION PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE PRODUCT IS THE SAME AS THE MAINS POWER SUPPLY IN YOUR AREA This product must be installed by a qualified professional Always operate the equipment as described in the user manua
2. 0 255 STR 0 20 STATIC COLOUR Combine Red Green Blue and White to create an infinite range of colors 0 255 Setthe value ofthe Strobe 0 20Hz 3 4 ACTIVATING AUTO PROGRAMS gt ENTER aut AUTO Selectthe target AUT program and press ENTER Programs A 01 to A 10 are fully pre programmed and will not be altered by changes in ENTER mode 3 5 RUN MODE gt ENTER gt RN 512 RUN 1 Enter the RUN mode to set working mode DMX modeisforusing the DMX512 controller to control the fixtures 9 SLA mode for Master Slave operation TIGHT RESEARCH 3 6 DMX512SETTINGS ENTER app gt 001 512 DMX Enter the DMX mode to set the DMX ADD 3 7 PERSONALITY ENTER gt PER TOR A1 ATD A 2 A2 D 425 Heu PERSONALITY Enter the PERSONALITY mode to select DMX mode TOUR A11 41 0 A 21 42 01 A2 S1 HSU 3 8 SPECIAL SETTINGS ENTER gt gt UPL_ 95 gt RST YES COL gt UC OFF RGB DIN gt 4 DRR SAU OUT SETTING Select UPLD to upload the custom programs from the current MASTER unit to the SLAVE units In order to activate the upload function the password must be entered Password is the same as the main access password When uploading the MASTER and SLAVE units will dis
3. MICRO BEAMER NO COLOR SHADOWS Operation Manual RECYCLE EN DISPOSAL OF THE DEVICE Dispose of the unit and used batteries in an environment friendly manner according to your country regulations FR D CLASSER L APPAREIL D barrassez vous de l appareil et des piles usag es de mani re cologique Conform ment aux dispositions l gales de votre pays NL VERWIJDEREN VAN HET APPARAAT Verwijder het toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GERATS Entsorgen Sie das Ger t und die Batterien auf umweltfreundliche Art und Weise gem den Vorschriften Ihres Landes ES DESHACERSE DEL APARATO Reciclar el aparato y pilas usadas de forma ecologica conforme a las disposiciones legales de su pais DESFAZER SE DA UNIDADE Tente reciclar a unidade e as pilhas usadas respeitando o ambiente e em conformidade com as normas vigentes no seu pa s TIGHT RESEARCH ABLE OF CONTENTS PART 1 PRODUCT 1 1 1 TECHNICAL 5 2 7 2441 7 5 7 1 2 SAFETY WARNING iid tete o rte ce ds 2 PART 2 3 2 3 2 2 SIGNAL 5 nenne nne 3 2 3 SETTING UP WITH A DMX512 CONTROLLER STAGE 1 MODE
4. 100 BLUE 0 51 lt gt 70 RED 0 GREEN 100 BLUE UP 71 lt gt 90 RED 0 GREEN DOWN BLUE 100 91 lt gt 110 RED UP GREEN 0 BLUE 100 111 lt gt 130 RED 100 GREEN 0 BLUE DOWN 131 lt gt 150 RED 100 GREEN UP BLUE UP 151 170 RED DOWN GREEN DOWN BLUE 100 171 lt gt 200 RED 100 GREEN 100 BLUE 100 WHITE100 201 lt gt 205 WHITE 1 3200K 206 210 WHITE 2 3400K 211 lt gt 215 WHITE 3 4200K 216 lt gt 220 WHITE 4 4900K gt Breq TIGHT RESEARCH CHANNEL VALUE FUNCTION 221 lt gt 225 WHITE 5 5600K 226 lt gt 230 WHITE 6 5900K 6 231 lt gt 235 WHITE 7 6500K WHITE 8 7200K 241 lt gt 245 WHITE 9 8000K 246 lt gt 250 WHITE 10 8500K 251 lt gt 255 WHITE 11 10000K STROBE 7 0 lt gt 10 NO FUNCTION 11 lt gt 255 FROM SLOW TO FAST AUTO NO FUNCTION AUTOI AUTO2 AUTO3 71 lt gt 80 AUTO4 8 81 lt gt 90 AUTOS 91 lt gt 100 AUTO6 10K gt 110 AUTO7 111 lt gt 120 AUTO8 121 lt gt 130 AUTO9 131 lt gt 255 AUTO10 9 0 lt gt 255 AUTO SPEED ADJUSTMENT Breq TIGHT RESEARCH Arc 1 CHANNEL VALUE FUNCTION 1 0 lt gt 255 RED 2 0 lt gt 255 GREEN 3 0 lt gt 255 BLUE Ar1 d CHANNEL VALUE FUNCTION 1 0 lt gt 255 MASTER DIMMER 2 0 lt gt 255 RED 3 0 lt gt 255 GREEN 4 0 lt gt 255 BLUE Arc 2 CHANNEL VALUE F
5. 5 YTE 0 255 Y 11 OUT OUT RGB RED 0 255 GRN 0 255 BLU 0 255 YTE 0 255 OUT Press ENTER button to enter the password confirmation to enter the correct password lt UP DOWN UP DOWN gt Key press the ENTER in the correct password will enter show submenu CAL Enterthe CAL to select white color of different color temperature There 11 pre programmed White colors can be edited by using Red Green Blue amp White Enter the CAL to adjust the RGB parameter to make different whites When the new setting is activated the DMX controller choose RGB 255 255 255 the white color will be made by the actual RGB values onthe CAL TIGHT RESEARCH 4 CONTROL WITH ADMX512 CONTROLLER 4 1 4 2 BASIC ADDRESSING Connect all of the units in series using standard DMX512 signal cable 9 Set the DMX512 address in the DIP switch It is possible to have the same DMX address or independent addresses for each fixture CHANNEL ASSIGNMENT Note This product has three DMX512 channel configurations STAGE1 ARC1 and ARC21 5 1 VALUE FUNCTION 0 255 DIMMER 0 255 RED 0 255 GREEN 0 lt gt 255 BLUE 0 lt gt 255 WHITE COLOR MACRO 0 lt gt 10 NO FUNCTION 11 lt gt 30 RED 100 GREEN UP BLUE 0 31 lt gt 50 RED DOWN GREEN
6. 512 may be used Example DMX Adar 1 DMX Addr 10 DMX Adar 19 29 1 DMX512 CONTROLLER The figure above shows a simple DMX512 layout with the starting address of the first unit set at 1 with the second setat 10 and SO On TIGHT RESEARCH ENTER UP DOWN 1 Choose one or retum to the previous menu scroll UP through the menu list or increase the value of the current function scroll DOWN through the menu list or decrease the value of the current function 3 2 MENU 3 DISPLAY PANEL OPERATION 3 1 BASIC ENTER UP DOWN ENTER gt sr RED 0 255 GRN 0 255 BLU 0 255 YTE 0 255 STR gt 0 20 OUT AUT gt 1 02 A40 RUN e 512 SLA ADD gt 001 512 PER TOR SET A1 A1 D A 2 A2 D A2 S HSU RST j YES COL UC OFF RGB DIN 24 3 J gt UPL e END TIGHT RESEARCH LOC gt ON OFF CAL p Y 01 RED lt 0 255 Y 02 GRN 0 255 BLU 0 255 YIE 0 255 Y 11 RGB RED e 0 255 GRN 0 255 BLU 0 255 0 255 OUT 3 3 EDIT STATIC COLOUR ENTER sr gt RED 0 255 0 255 BLU gt 0 255
7. UNCTION 1 0 lt gt 255 RED 2 0 lt gt 255 GREEN 3 0 lt gt 255 BLUE 4 0 lt gt 255 WHITE 11 TIGHT RESEARCH Ar2 d CHANNEL VALUE FUNCTION 1 MASTER DIMMER 2 0 lt gt 255 RED 3 0 lt gt 255 GREEN 4 0 lt gt 255 BLUE 5 0 lt gt 255 WHITE Ar2 s CHANNEL VALUE FUNCTION 1 0 lt gt 255 MASTER DIMMER 2 0 lt gt 255 3 0 lt gt 255 GREEN 4 0 lt gt 255 BLUE 5 0 lt gt 255 WHITE 6 0 lt gt 255 STROBE HSV CHANNEL VALUE FUNCTION 1 0 gt lt 255 HUE 0 100 2 0 lt gt 255 SATURATION 0 100 3 0 lt gt 255 VALUE 0 100 212 TIGHT RESEARCH D APPENDIX 5 1 MAINTENANCE ITEM Head cover Abrazine slice Lens frame2 Lens Lens frame1 LED board Thermal protection device 3 5 Screw 10 Head casing main section1 Bracket 1 11 12 Bracket 2 Display PCB 13 14 15 Control board Prive PCB Heat sink Display glass 17 18 Isolator sheet Power supply 19 Head casing main section2 TIGHT RESEARCH
8. hall be changed if it has become damaged or thermally deformed TIGHT RESEARCH 2 INSTALLATION 2 7 MOUNTING UPRIGHT The LED Fixture can be mounted in a sitting or wall mounted position using the supporting brackets The LED Fixture should be placed on a non flammable flat surface in any orientation and fixed by screws There are four holes into the supporting bracket HANGING The LED fixture can be mounted in a hanging position using the supporting bracket The bracket should be secured to the mounting truss or structure using a standard mounting clamp Please note that when hanging the unit a safety cable should also be used position Itis possible to further adjust the angle of the LED MODULE using the two adjustment knobs located on the side of NOTE the fixture The LED MODULE can be mounted at any angle and in any 2 2 SIGNAL CONNECTIONS Note 1 If over 25units to be connected then a DMX signal amplifier is needed 2 If the signal cable is over 60m between the DMX512 controller and fixture or beween two fixtures then a DMX signal amplifier is needed as well TIGHT RESEARCH 2 3 SETTING UP WITHADMX512 CONTROLLER STAGE 1 MODE Connect the DMX512 controller to the units in series Each unit has 9 DMX channels so the DMX Addresses should increase by increments of 9 e g 1 10 19 28 Each DMX Address may be used as many times as required Any DMX address the range from 001 to
9. l minimum distance of 0 5m must be maintained between the equipment and combustible surface The product must always be placed in a well ventilated area Always make sure that the equipmentis installed securely DO NOT stand close to the equipment and stare directly into the LED light source Always disconnect the power supply before attempting and maintenance Always make sure that the supporting structure is solid can support the combined weight of the products The earth wire must always be connected to the ground Do not touch the power cables if your hands are wet ATTENTION This product left the place of manufacture in perfect condition In order to maintain this condition and for safe operation the user must always follow the instructions and safety warnings described in this user manual 9 Avoid shaking or strong impacts to any part of the equipment Make sure that all parts of the equipment kept clean and free of dust Always make sure that the power connections are connected correctand secure If there is any malfunction of the equipment contact your distributor immediately When transferring the product itis advisable to use the original packaging in which the product left the factory Shields lenses or ultraviolet screens shall be changed if they have become damaged to such extent that their effectiveness is impaired The lamp LED s
10. play YELLOW If an error occurs when uploading the MASTER and or SLAVE units will display RED On successful uploading of the custom programs the MASTER and SLAVE units will display GREEN In order to reset custom modes to default values select REST COLOR is for activate unactivate the color calibration functions When RGBW is selected on RGB 255 255 255 the color is displayed as calibrated in CAL2 RGBW When COLOR isset OFF on RGB 255 255 255 the RGB values are not adjusted and the output is most powerful When UC is selected the RGB output are adjusted to a standard preset universal color which balances fixtures from different generations DERR Choose Save inorder to save the last DMX data incase of DMX signal error Choose Black in order to blackout in case of DMX signal error Breq TIGHT RESEARCH 3 9 ACTIVATE THE PASSWORD ENTER gt gt OFF LOC Enter the LOC mode to select whether the access password is on or off When the fixture is set as PASS ON after 30 seconds or turn on the fixture next time the fixture will need an access password to enter the display menu control Note The factory access password is UP DOWN UP DOWN then press ENTER to confirm the access 3 10 BALANCE PARAMETERS AND CORRECTION MENU DISPLAY CAL gt Y 01 RED 0 255 2 Y 0 GRN 0 255 BLU 0 25
Download Pdf Manuals
Related Search
Related Contents
1 - Brother Yamaha RX-V373BL-B AV receiver 第60回 定時株主総会招集通知(PDF:688KB) Samsung WF692U0BKWQ/SV Hướng dẫn sử dụng LES CONTROLEURS AS34/AS34DBL : (avec carte Nuevo Tablero de Alumbrado NQ Easy Riser™ Bluetooth Wireless Notebook Mouse manual Panamax MAX M5300-EX User's Manual Copyright © All rights reserved.