1. Plug configuration Effect 1 3 i CFG o a A Pilot valve opened 2 3 1 4 CFC 1 2 i CFG u en Pilot valve closed 4 3 j 4 3 CFC 8 MANUAL CONTROL 0 rest position 1 switching position Fig 4 Manual control based on the example of Type 5470 9 DISASSEMBLY Disassembly is in reverse sequence to assembly 10 MAINTENANCE TROUBLESHOOTING If the valve is used according to these operating instructions the valve will operate maintenance free 10 1 Safety instructions WARNING Risk of injury from improper maintenance gt Maintenance may only be carried out by authorized technicians and with the appropriate tools Risk of injury due to electrical shock gt Before reaching into the device or the equipment switch off the power supply and secure to prevent reactivation Danger high pressure gt Turn off the pressure and vent the lines before loosening lines or valves Risk of injury from unintentional activation of the system and uncontrolled restart gt Secure system against unintentional activation gt Following maintenance ensure a controlled restart E 10 2 Malfunctions If malfunctions occur check whether the device has been installed according to the instructions the electrical and pneumatic connections are correct the device is not damaged all screws have been tightened the voltage and pressure have been
2. gt Desserrer les vis M2 et retirer la bobine du corps de la vanne gt Tourner la bobine la mettre en place sur le corps de la vanne et la visser progressivement et en alternant l aide des vis M2 Ce faisant respecter le couple de serrage Type 0470 5470 Couple de serrage 1 niveau 0 1 Nm 0 05 Nm 2 me niveau 0 2 Nm 0 05 Nm Fig 2 Typ 5470 La bobine magn tique de la vanne pilote peut tre tourn e de 180 32 7 3 Transformation de la vanne 4 2 voies en 3 2 voies Pour transformer la vanne 4 2 voies en 3 2 voies il convient d obturer le raccord 2 ou le raccord 4 avec un bouchon selon la fonction souhait e Raccord 2 Raccord 4 Fonction 2 2 g ferm ouvert C nal 1 3 aan 2 to E ouvert ferm D NL 1 3 a 7 4 Raccordement pneumatique A AVERTISSEMENT Risque de blessures d des pi ces d appareil soumises une forte acc l ration et la pr sence de flexibles d air comprim non raccord s qui vont dans tous les sens gt Avant d appliquer la pression la vanne v rifier que tous les raccords de flexible et raccords vis sont correctement en place Position de montage au choix de pr f rence syst me magn tique vers le haut Avant le raccordement gt Contr ler la pr sence d encrassement au niveau des tuyaux flexibles et nettoyer le cas ch ant gt Si n cessaire installer
3. Danger high pressure gt Turn off the pressure and vent the lines before loosening lines or valves Risk of electric shock gt Before reaching into the device or the equipment switch off the power supply and secure to prevent reactivation gt Observe applicable accident prevention and safety regulations for electrical equipment Risk of injury from greatly accelerated device parts gt Before pressurizing the valve check that all screw connections and screw joints are tight and secure Risk of burns danger of fire during long term operation due to hot device surface gt Keep the device away from highly flammable substances and media and do not touch with bare hands To prevent injuries damage gt Do not make any internal or external changes to the device and safeguard against unintentional actuation gt Installation and maintenance work may be carried out only by autho rized technicians with the appropriate tools gt After an interruption in the electrical or pneumatic supply ensure that the process is restarted in a defined or controlled manner gt Do not subject the housing to mechanical loads gt Observe the general accepted technical rules 3 1 Restrictions If exporting the device observe any existing restrictions 4 APPROVALS The approval mark indicated on the Biirkert labels refers to the B rkert products Devices which must bear the type approval mark were approved at
4. Mise en garde contre les blessures l g res ou moyennement graves A ATTENTION 1 2 D finition du terme appareil Le terme appareil utilis dans ce manuel d signe toujours les types 0470 et 5470 Mise en garde contre les dommages mat riels REMARQUE Type 0470 5470 2 UTILISATION CONFORME L utilisation non conforme de l lectrovanne types 0470 5470 peut pr senter des risques pour les personnes les installations proches et l environnement gt L appareil sert exclusivement d lectrovanne 3 2 ou 4 2 voies pour les fluides autoris s conform ment la fiche technique du type correspondant gt Avec un connecteur connect et mont de mani re conforme par ex le type 2506 de B rkert pour le type 5470 ou le type 1054 pour le type 0470 l appareil est conforme au degr de protection IP65 selon DIN EN 60529 IEC 60529 gt Dans une zone expos e un risque d explosion l appareil doit imp rativement tre utilis conform ment la sp cification indiqu e sur la plaque signal tique de s curit s par e L information suppl mentaire comportant des consignes de s curit pour zone pr sentant des risques d explosion fournie avec l appareil doit tre respect e lors de l utilisation de celui ci gt Les appareils sans plaque signal tique de s curit s par e ne doivent pas tre install s dans une zone soumise un risque d explosion Lors de l utilisation il convi
5. DIN ISO 175301 803 forme C Respecter le couple de serrage max Fig 3 Raccordement lectrique du connecteur exemple type 5470 gt Visser le connecteur types admissibles voir fiche technique en respectant le couple de serrage maximal 0 3 Nm gt V rifier le bon positionnement du joint gt Raccorder le conducteur de protection et v rifier le passage du courant entre la bobine et le corps voir Tab 1 34 MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 REMARQUE Si vous montez le connecteur de sorte que la vis est dirig e vers le haut il convient d ins rer un joint dont le mat riau est compatible avec votre process sous la t te de vis Q Respecter la tension et le type de courant selon la plaque signal tique R sistance Tension d essai Courant d essai max 0 1 Q 12V 1A Tab 1 Valeurs d essai de la fonction de conducteur de protection Type 0470 5470 7 6 Commande ex cution impulsions La polarit correcte est la condition sine qua non du fonction nement de l appareil respecter l identification figurant sur la surface de la bobine Dur e d impulsion minimale 50 ms broche 1 broche 2 broche 1 broche 2 8 COMMANDE MANUELLE 0 position de repos 1 position de commutation Fig 4 Commande manuelle en prenant pour exemple le t
6. ssiger Angaben auf Typschild beachten Druckbereich Druckdifferenz mindestens 2 bar zwischen Anschl ssen 1 und 3 Schutzart IP65 nach DIN EN 60529 IEC 60529 mit sachgem angeschlossener und montierter Ger testeckdose z B B rkert Typ 2506 Betriebsdauer Wenn auf dem Typschild nicht anders angegeben ist das Magnetsystem f r Dauerbetrieb geeignet 1 Um ein Vereisen der expandierten Druckluft zu vermeiden muss deren Drucktaupunkt mindestens 10 K niedriger als die Mediumstemperatur sein E Wichtiger Hinweis f r die Funktionssicherheit bei Dauerbetrieb Bei langem Stillstand wird eine Mindestbet tigung von 1 2 Schaltungen pro Tag empfohlen Lebensdauer Hohe Schaltfrequenz und hohe Dr cke verringern die Lebensdauer Die Ventile arbeiten wartungsfrei 6 5 Werkstoffe Geh usewerkstoff PA Dichtwerkstoff NBR 7 MONTAGE 7 1 Sicherheitshinweise GEFAHR Verletzungsgefahr durch hohen Druck in der Anlage gt Vor dem L sen von Leitungen oder Ventilen den Druck abschalten und Leitungen entlasten Verletzungsgefahr durch Stromschlag gt Vor Eingriffen in das Ger t oder die Anlage Spannung abschalten und vor Wiedereinschalten sichern gt Die geltenden Unfallverh tungs und Sicherheitsbestimmungen f r elektrische Ger te beachten WARNUNG Verletzungsgefahr durch stark beschleunigte Ger teteile und nicht verbundene herumschlagende Druckluftschl uche gt Vor Beaufschlagen
7. Ventilen den Druck abschalten und Leitungen entlasten Verletzungsgefahr durch elektrische Spannung gt Vor Eingriffen in das Ger t oder die Anlage Spannung abschalten und vor Wiedereinschalten sichern gt Die geltenden Unfallverh tungs und Sicherheitsbestimmungen f r elektrische Ger te beachten Verletzungsgefahr durch stark beschleunigte Ger teteile gt Vor Beaufschlagen des Ventils mit Druck alle Schlauchverbindun gen und Verschraubungen auf festen sicheren Sitz berpr fen Verbrennungsgefahr Brandgefahr bei Dauerbetrieb durch hei e Ger teoberfl che gt Das Ger t von leicht brennbaren Stoffen und Medien fernhalten und nicht mit blo en H nden ber hren Zum Schutz vor Verletzungen Sachsch den beachten gt Am Ger t keine inneren oder uBeren Ver nderungen vornehmen und vor unbeabsichtigter Bet tigung sichern gt Installations und Instandhaltungsarbeiten d rfen nur von autorisier tem Fachpersonal mit geeignetem Werkzeug ausgef hrt werden gt Nach einer Unterbrechung der elektrischen oder pneumatischen Versorgung ist ein definierter oder kontrollierter Wiederanlauf des Prozesses zu gew hrleisten gt Geh use nicht mechanisch belasten gt Die allgemeinen Regeln der Technik einhalten 3 1 Beschr nkungen Beachten Sie bei der Ausfuhr des Ger ts gegebenenfalls bestehende Beschr nkungen 4 ZULASSUNGEN Die auf den B rkert Typschildern aufgebrachte Zulassungskenn zeic
8. and fitted cable plug e g Burkert Type 2506 Operating Unless otherwise indicated on the type label the duration solenoid system is suitable for continuous operation n To prevent the expanded compressed air from freezing its pressure dew point must be at least 10 K lower than the medium temperature Important information for functional reliability during continuous Q operation If the equipment is switched off for a long period it is recom mended to activate the valves at least 1 2 per day Service life High switching frequency and high pressures reduce the service life The valves operate maintenance free 6 5 Materials Housing material PA Seal material NBR 7 ASSEMBLY 7 1 Safety instructions DANGER Risk of injury from high pressure in the system gt Turn off the pressure and vent the lines before loosening lines or valves Risk of injury due to electrical shock gt Before reaching into the device or the equipment switch off the power supply and secure to prevent reactivation gt Observe applicable accident prevention and safety regulations for electrical equipment WARNING Risk of injury from greatly accelerated device parts and uncon nected whiplashing compressed air hoses gt Before pressurizing the valve check that all screw connections and screw joints are tight and secure Risk of injury from improper assembly gt Assembly may only be carried out by authorized tec
9. connecteur connect et mont de mani re conforme par ex le type 2506 de B rkert Dur e de Si aucune information contraire ne figure sur la fonctionnement plaque signal tique le syst me magn tique est adapt un fonctionnement continu n Pour viter le givrage de l air comprim d tendu son point de ros e doit tre inf rieur d au moins 10 K par rapport la temp rature du fluide 30 Remarque importante pour la s curit de fonctionnement lors d un fonctionnement continu Dans le cas d un arr t prolong il est recommand de proc der 1 2 commutations minimum par jour Dur e de vie Une fr quence lev e de commutation ainsi que des pressions lev es r duisent la dur e de vie Les vannes ne n cessitent aucune maintenance 6 5 Mat riaux Mat riau du corps PA Mat riau du joint NBR 7 MONTAGE 7 1 Consignes de s curit A DANGER Risque de blessures d la pr sence de haute pression dans l installation gt Avant de desserrer les conduites ou les vannes couper la pression et purger l air des conduites Risque de choc lectrique gt Avant d intervenir dans l appareil ou l installation coupez la tension et emp chez toute remise sous tension par inadvertance gt Respectez les r glementations en vigueur pour les appareils lec triques en mati re de pr vention des accidents et de s curit A AVERTISSEMENT Risque de bl
10. des Ventils mit Druck alle Schlauchverbindun gen und Verschraubungen auf festen sicheren Sitz berpr fen Verletzungsgefahr bei unsachgem er Montage gt Die Montage darf nur autorisiertes Fachpersonal mit geeignetem Werkzeug durchf hren 19 MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 Verletzungsgefahr durch ungewolltes Einschalten der Anlage und unkontrollierten Wiederanlauf gt Anlage vor unbeabsichtigtem Bet tigen sichern gt Nach der Montage einen kontrollierten Wiederanlauf gew hrleisten 7 2 Typ 5470 Drehen der Magnetspule Die Ventile werden fertig montiert geliefert Sollte die Lage der Mag netspule des Vorsteuerventils f r die Montage ung nstig sein kann die Spule um 180 gedreht werden WARNUNG Gefahr durch Stromschlag bei falscher Montage der Spule gt Bei der Montage beachten dass die Spule fest auf dem Ventilk r per aufsitzt damit der Schutzleiteranschluss der Spule Verbindung zum Ventilgeh use hat gt Schutzleiterfunktion pr fen Pr fwerte siehe Tab 1 auf Seite 23 gt Schrauben M2 l sen und Spule vom Ventilk rper abziehen Spule drehen auf Ventilk rper aufsetzen und mit Schrauben M2 abwechselnd stufenweise verschrauben Dabei Anziehdreh moment beachten Typ 0470 5470 Anziehdrehmoment 1 Stufe 0 1 Nm 0 05 Nm 2 Stufe 0 2 Nm 0 05 Nm Bild 2 Typ 5470 Magnetspule des
11. gt Nach der Wartung einen kontrollierten Wiederanlauf gew hrleisten Die Demontage erfolgt in entgegengesetzter Reihenfolge zur Montage z 10 2 St rungen 11 TRANSPORT LAGERUNG Bei St rungen berpr fen ob ENTSORGUNG das Ger t vorschriftsm ig installiert ist HINWEIS der elektrische und pneumatische Anschluss ordnungsgem ausgef hrt ist Transportsch den das Ger t nicht besch digt ist Unzureichend gesch tzte Ger te k nnen durch den Transport besch digt werden gt Ger t vor N sse und Schmutz gesch tzt in einer sto festen Ver packung transportieren alle Schrauben fest angezogen sind Spannung und Druck anliegen die Rohrleitungen schmutzfrei sind gt Eine ber bzw Unterschreitung der zul ssigen Lagertemperatur die Handbet tigung in Ruhestellung steht vermeiden gt Elektrische Schnittstellen der Spule und die pneumatischen Ventil schaltet nicht Anschl sse mit Schutzkappen vor Besch digungen sch tzen M gliche Ursache Kurzschluss oder Spulenunterbrechung Falsche Lagerung kann Sch den am Ger t verursachen gt Ger t trocken und staubfrei lagern Kern oder Kernraum verschmutzt gt Lagertemperatur 40 C 80 C Mediumseruek aubsthalbides zul ssigen Druckbersichs Umweltsch den durch von Medien kontaminierte Ger teteile Ventil schlie t nicht gt Ger t und Verpackung umweltgerecht entsorgen M gliche Ursache gt Gelt
12. the Kraftfahrtbundesamt under the type approval number e1 72 245 2006 96 5791 00 and are put into circulation with the indicated type approval mark 035791 You can obtain an extract of the type approval from the address below Burkert Werke GmbH CQ Approval Management Christian B rkert Str 13 17 D 74653 Ingelfingen 5 STRUCTURE AND FUNCTION The valves can be mounted in blocks on the modular pneumatic base rail Type MPO5 5 1 Structure of the standard designs 5 1 1 Connections All connections are identified by numbers on the valve surface These refer to the following functions Number Function 1 Pressure inlet port 2 und 4 Working port 3 Exhaust port i MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 5 1 2Valve structure Type 5470 Cable plug Pilot valve Type 2506 Type 6106 Manual control Exhaust port 3 Pressure inlet port 1 Working port 4 A Type 0470 5470 5 2 Circuit functions 3 2 way valve Normally inlet port 1 closed working port 2 connected with exhaust port 3 3 2 way valve Normally inlet port 1 connected with working port 2 exhaust port 3 closed 4 2 way valve Normally inlet port 1 connected with working Exhaust port 3 gt Pressure inlet port 1 gt Working port 4 4 Working port 2 Working port 2 port 2 working port 4 connected wit
13. un filtre boue en amont de l entr e de vanne lt 5 um Raccordement pneumatique REMARQUE Attention risque de rupture gt Ne pas utiliser la bobine comme levier gt Ne pas utiliser de cl tubes lors du vissage gt Maintenir l appareil la main au niveau du corps de la vanne et le raccorder au tuyau flexible Ne pas d passer la profondeur de vissage prescrite gt Utiliser une bande PTFE ou un joint en lastom re pour tancher Respecter l affectation des raccords voir chapitre 5 1 1 Raccords page 28 gt Aligner les tuyaux flexibles 7 5 Raccordement electrique A AVERTISSEMENT Risque de choc lectrique gt Avant d intervenir dans le syst me coupez la tension et emp chez toute remise sous tension par inadvertance gt Respectez les r glementations en vigueur pour les appareils lectriques en mati re de pr vention des accidents et de s curit gt Lorsque vous vissez la bobine avec la prise de l appareil veillez au positionnement parfait du joint ll y a risque de choc lectrique en l absence d un contact du conducteur de protection entre la bobine et le corps de la vanne gt Raccordez toujours le conducteur de protection gt Contr lez le passage du courant entre la bobine et le corps de la vanne 33 7 5 1 Raccordement lectrique du connecteur Exemple type 5470 Connecteur autoris par ex type 2506 ou autres selon
14. Bedienungsanleitung Manuel d utilisation DE B rkert Fluid Control Systems b u r ke r t Sales Center Christian B rkert Str 13 17 D 74653 Ingelfingen Tel 49 0 7940 10 91 111 Fax 49 0 7940 10 91 448 E mail info de buerkert com FLUID CONTROL SYSTEMS www burkert com MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 1 DIE BEDIENUNGSANLEITUNG Die Bedienungsanleitung enth lt wichtige Informationen gt Die Bedienungsanleitung sorgf ltig lesen und die Hinweise zur Sicherheit beachten gt Die Bedienungsanleitung muss jedem Benutzer zur Verf gung stehen gt Die Haftung und Gew hrleistung f r Typ 0470 5470 entf llt wenn die Anweisungen der Bedienungsanleitung nicht beachtet werden 1 1 Darstellungsmittel gt markiert eine Anweisung zur Gefahrenvermeidung gt markiert einen Arbeitsschritt den Sie ausf hren m ssen Warnung vor schweren oder t dlichen Verletzungen GEFAHR WARNUNG Bei unmittelbarer Gefahr Bei m glicher Gefahr Warnung vor leichten oder mittelschweren Verletzungen Warnung vor Sachsch den A VORSICHT HINWEIS 1 2 Begriffsdefinition Ger t Der in der Anleitung verwendete Begriff Ger t bezeichnet immer den Typ 0470 5470 Typ 0470 5470 2 _BESTIMMUNGSGEM SSER GEBRAUCH Bei nicht bestimmungsgem em Einsatz des Magnetventils Typ 0470 5470 k nnen Gefahren f r Personen Anlagen in der Umgebung u
15. ES TECHNIQUES 6 1 Conformit L lectrovanne types 0470 5470 satisfait aux directives CE confor m ment a la d claration de conformit CE 6 2 Normes Les normes utilis es avec lesquelles la conformit avec les directives CE sont prouv es figurent dans l attestation CE de type et ou la d claration de conformit CE 6 3 Plaque signal tique Mode d action Type a gt 5470 G 4 0 2 G1 8 PN2 10bar 24V DC 2W Exemple Diam tre nominal Type de raccordement plage de pression admissible n Tension 10 fr quence puissance urke 3 ce IQ 00203236 w yMmG Num ro de commande L Code fabricant Fig 1 Exemple plaque signal tique de l lectrovanne pilot e type 5470 29 6 4 Conditions d exploitation Veuillez respecter les indications figurant sur la fiche technique et la plaque signal tique Temp rature 10 C 55 C veuillez observer les limitations ambiante de temp rature reposant sur les homologations Temp de fluide 10 C 50 C admissible Qualit de l air 7 1 comprim ISO 8573 1 2010 classe 7 4 4 Fluides autoris s Air comprim filtr lubrifi et non lubrifi gaz neutres Plage de Respecter les indications sur la plaque signal tique pression Diff rence de pression minimale de 2 bars entre les admissible raccords 1 et 3 Degr de IP65 selon DIN EN 60529 IEC 60529 avec protection un
16. MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 burkert FLUID CONTROL SYSTEMS Type 0470 5470 3 2 or 4 2 way solenoid valve 3 2 bzw 4 2 Wege Magnetventil Electrovanne 3 2 ou 4 2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation EN B rkert Fluid Control Systems b u r ke r t Sales Center Christian B rkert Str 13 17 D 74653 Ingelfingen Tel 49 0 7940 10 91 111 Fax 49 0 7940 10 91 448 E mail info de buerkert com FLUID CONTROL SYSTEMS www burkert com MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 1 THE OPERATING INSTRUCTIONS The operating instructions contain important information gt Read the operating instructions carefully and follow the safety instructions in particular gt The operating instructions must be available to every user gt The liability and warranty for Type 0470 5470 are not applicable if the operating instructions are not followed 1 1 Symbols gt Designates instructions for risk prevention Designates a procedure which you must carry out Warning of serious or fatal injuries DANGER In case of imminent danger WARNING In case of potential danger Warning of minor or moderately severe injuries Warning of damage A CAUTION NOTE 1 2 Definition of the term device The term device used in the instructions always refers
17. Vorsteuerventils kann um 180 gedreht werden 20 7 3 Umbau von 4 2 in 3 2 Wege Ventil Zum Umbau des 4 2 Wege Ventils in ein 3 2 Wege Ventil muss je nach gew nschter Wir kungsweise Anschluss 2 oder Anschluss 4 mit einem Stopfen verschlossen werden Anschluss 2 Anschluss 4 Wirkungsweise 2 12 F verschlossen offen C eh 13 Weng 2 fo offen verschlossen D NS 1 3 ne 7 4 Pneumatischer Anschluss WARNUNG Verletzungsgefahr durch stark beschleunigte Ger teteile und nicht verbundene herumschlagende Druckluftschl uche gt Vor Beaufschlagen des Ventils mit Druck alle Schlauchverbindun gen und Verschraubungen auf festen sicheren Sitz berpr fen Einbaulage beliebig vorzugsweise Magnetsystem oben Vor dem Anschluss gt Schlauchleitungen auf Verschmutzungen berpr fen und reinigen Vor den Ventileingang einen Schmutzfilter einbauen lt 5 um Pneumatischer Anschluss HINWEIS Vorsicht Bruchgefahr gt Spule nicht als Hebelarm benutzen gt Beim Einschrauben keine Rohrzange verwenden Das Ger t von Hand am Geh use festhalten und mit der Schlauch leitung verbinden Dabei Normeinschraubtiefe nicht berschreiten Zum Abdichten Elastomerdichtung oder PTFE Band verwenden Die Zuordnung der Anschl sse beachten siehe Kapitel 5 1 1 Anschl sse auf Seite 16 gt Schlauchleitungen ausrichten 7 5 Elektrischer Anschl
18. ach an Anschluss 3 offen D 4 A 3 2 Wege Ventil ZN In Ruhestellung Druckanschluss 1 nach 13 Arbeitsanschluss 2 ge ffnet Anschluss 3 geschlossen G B 4 2 Wege Ventil ext i in Ruhestellung Druckanschluss 1 nach ER Arbeitsanschluss 2 ge ffnet Arbeitsanschluss t 4 nach Ausgang 3 ge ffnet 6 TECHNISCHE DATEN 6 1 Konformit t Das Magnetventil Typ 0470 5470 ist konform zu den EG Richtlinien entsprechend der EG Konformit tserkl rung 6 2 Normen Die angewandten Normen mit denen die Konformit t mit den EG Richt inien nachgewiesen wird sind in der EG Baumusterpr fbescheinigung und oder der EG Konformit tserkl rung nachzulesen 6 3 Typschild Beispiel Wirkungsweise Typ Nennweite Anschlussart zul ssiger Druckbereich 5470 G 4 0 G1 8 PN2 10bar 24V DC 2W Spannung 10 re Stromart Frequenz 00203236 w yma Leistung Bestellnummer _ L Hersteller Code Bild 1 Beispiel eines Typschilds des vorgesteuerten Magnetventils Typ 5470 17 6 4 Betriebsbedingungen Q Bitte die Angaben auf dem Datenblatt und dem Typschild beachten Mediumstemp Umgebungs 10 C 55 C bitte Temperatureinschr n temperatur kungen aufgrund von Zulassungen beachten Zul ssige 10 C 50 C Druckluftqualit t ISO 8573 1 2010 Klasse 7 4 4 Zul ssige Gefilterte Druckluft ge lt und unge lt Medien neutrale Gase Zul
19. ende Entsorgungsvorschriften und Umweltbestimmungen einhalten Innenraum des Ventils verschmutzt MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 burkert FLUID CONTROL SYSTEMS Type 0470 5470 3 2 or 4 2 way solenoid valve 3 2 bzw 4 2 Wege Magnetventil Electrovanne 3 2 ou 4 2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation FR B rkert Fluid Control Systems b u r ke r t Sales Center Christian B rkert Str 13 17 D 74653 Ingelfingen Tel 49 0 7940 10 91 111 Fax 49 0 7940 10 91 448 E mail info de buerkert com FLUID CONTROL SYSTEMS www burkert com MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 1 MANUEL D UTILISATION Le manuel d utilisation contient des informations importantes gt Lire attentivement le manuel d utilisation et tenir compte des consignes de s curit gt Le manuel d utilisation doit tre mis disposition de chaque utilisateur gt La responsabilit et la garantie l gale concernant le type 0470 5470 sont exclues en cas de non respect des instructions figurant dans le manuel d utilisation 1 1 Symboles gt identifie une consigne pour viter un danger identifie une op ration que vous devez effectuer Mise en garde contre les blessures graves ou mortelles DANGER AVERTISSEMENT En cas de danger imminent En cas de danger possible
20. ent de respecter les donn es et conditions d utilisation et d exploitation admissibles sp cifi es dans les documents contractuels la fiche technique et le manuel d utilisation gt L appareil doit tre utilis seulement de fa on conforme v 26 gt Les conditions pour l utilisation s re et parfaite sont un transport un stockage et une installation dans les r gles ainsi qu une utilisation et une maintenance parfaites 2 1 Limitations Lors de l exportation de l appareil veuillez respecter les limitations ven tuelles existantes 3 CONSIGNES DE S CURIT FONDAMENTALES Ces consignes de s curit ne tiennent pas compte des hasards et des v nements pouvant survenir lors du montage de l exploitation et de la maintenance A Danger d la haute pression gt Avant de desserrer les conduites ou les vannes couper la pression et purger l air des conduites Danger pr sent par la tension lectrique gt Avant d intervenir dans l appareil ou l installation coupez la tension et emp chez toute remise sous tension par inadvertance gt Respectez les r glementations en vigueur pour les appareils lec triques en mati re de pr vention des accidents et de s curit Risque de blessures d des pi ces d appareil soumises une forte acc l ration gt Avant d appliquer la pression la vanne v rifier que tous les raccords de flexible et raccords vis sont correcteme
21. essures d des pi ces d appareil soumises une forte acc l ration et la pr sence de flexibles d air comprim non raccord s qui vont dans tous les sens gt Avant d appliquer la pression la vanne v rifier que tous les raccords de flexible et raccords vis sont correctement en place Risque de blessures d un montage non conforme gt Le montage doit tre effectu uniquement par un personnel qualifi et habilit disposant de l outillage appropri 31 MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 Risque de blessures d la mise en marche involontaire de l ins tallation et au red marrage non contr l gt Emp cher tout actionnement involontaire de l appareil gt Garantir un red marrage contr l apr s le montage 7 2 Type 5470 rotation de la bobine magn tique Les vannes sont livr es d j mont es Si la position de la bobine magn tique de la vanne pilote tait d favorable pour effectuer le montage il est possible de la tourner de 180 A AVERTISSEMENT Risque de choc lectrique en cas de montage erron de la bobine gt Lors du montage veiller ce que la bobine soit fermement en contact avec le corps de la vanne pour que le raccord du conducteur de pro tection de la bobine soit reli au corps de la vanne gt Contr ler la fonction du conducteur de protection valeurs d essai voir Tab 1 page 35
22. gen 27 5 STRUCTURE ET MODE DE FONCTIONNEMENT Les vannes peuvent tre mont es sur le rail de base pneumatique modulaire de type MPOS pour former des blocs de vannes 5 1 Structure des versions standard 5 1 1 Raccords Tous les raccords sont identifi s par des chiffres sur la surface de la vanne Ceux ci renvoient aux fonctions suivantes Chiffre Fonction 1 Raccord de pression 2 und 4 Raccord de travail 3 Raccord de purge 28 MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 5 1 2 Ensemble de vanne type 5470 Connecteur Vanne pilote type 2506 type 6106 Commande manuelle Raccord de purge 3 Raccord de pression 1 Raccord de travail 2 Type 0470 5470 5 2 Fonctions Vanne 3 2 voies Au repos le raccord de pression 1 est ferm le raccord de travail 2 est connect au raccord de purge 3 Vanne 3 2 voies Au repos le raccord de pression 1 est connect au raccord de travail 2 le raccord de purge 3 est ferm Vanne 4 2 voies Au repos le raccord de pression 1 est connect au raccord de travail 2 le raccord de travail 4 est connect au raccord de purge 3 5 1 3 Ensemble de vanne type 0470 Connecteur Bobine magn tique type 1054 type AC27 Raccord de purge 3 gt Raccord de pression 1 gt Raccord de travail 4 __4 Raccord de travail 2 6 CARACTERISTIQU
23. h exhaust 5 1 3 Valve structure Type 0470 port 3 Cable plug Solenoid coil Type 1054 Type AC27 6 TECHNICAL DATA 6 1 Conformity The solenoid valve Type 0470 5470 is compliant with EC directives as stated in the EC Declaration of Conformity 6 2 Standards The applied standards which are used to demonstrate compliance with the EC Directives are listed in the EC Prototype Examination Certificate and or the EC Declaration of Conformity 6 3 Type label Example Circuit function Type Orifice u gt 5470 G 4 0 Connection type G1 8 PN2 10bar permitted pressure range xe 24V DC 2W Voltage 10 z frequency DJ ce output IQ 00203236 wiyMG Order number _ J L_____ Manufacturer code Fig 1 Example of type label on the pilot controlled solenoid valve Type 5470 6 4 Operating conditions Please observe the specifications on the data sheet and on the type label Ambient 10 C 55 C please observe temperature temperature restrictions on account of approvals Permitted i 10 C 50 C medium temp Compr air quality ISO 8573 1 2010 Class 7 4 4 Permitted media Filtered compressed air oiled and unoiled neutral gases Permitted pressure range Observe specifications on type label Pressure difference at least 2 bar between ports 1 and 3 Degree of IP65 as per DIN EN 60529 IEC 60529 with protection correctly connected
24. hnicians and with the appropriate tools MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 Risk of injury from unintentional activation of the system and uncontrolled restart gt Secure system against unintentional activation gt Following assembly ensure a controlled restart 7 2 Type 5470 turning the solenoid coil The valves are supplied fully assembled If the solenoid coil in the pilot valve is in an unfavorable position for installation the coil can be turned 180 WARNING Risk of electrical shock if the coil is incorrectly fitted gt During installation make sure that the coil is firmly seated on the valve body so that the protective conductor connection of the coil is in contact with the valve housing gt Check the function of the protective conductor for test values see Tab 1 page 11 gt Loosen M2 screws and pull coil away from the valve body Turn coil attach to valve body and screw on with M2 screws tightening alternately step by step While doing so observe the tightening torque Type 0470 5470 Tightening torque 1st Level 0 1 Nm 0 05 Nm 2nd Level 0 2 Nm 0 05 Nm Fig 2 Typ 5470 The solenoid coil in the pilot valve can be turned by 180 7 3 Conversion from a 4 2 to a 3 2 way valve To convert the 4 2 way valve into a 3 2 way valve you must seal connection 2 or connection 4
25. hnung bezieht sich auf die B rkert Produkte Ger te die das Typgenehmigungszeichen tragen m ssen wurden beim Kraftfahrtbundesamt unter der Typgenehmigungsnummer e1 72 245 2006 96 5791 00 genehmigt und werden mit dem gezeigten Typgenehmigungzeichen in den Verkehr gebracht 035791 Einen Auszug der Typgenehmigung erhalten Sie unter folgender Adresse B rkert Werke GmbH CQ Approval Management Christian B rkert Str 13 17 D 74653 Ingelfingen E 5 AUFBAU UND FUNKTION Die Ventile k nnen auf der modularen pneumatischen Grundschiene Typ MPO5 zu Ventilbl cken montiert werden 5 1 Aufbau der Standard Ausf hrungen 5 1 1 Anschl sse Alle Anschl sse sind auf der Ventiloberfl che mit Nummern gekenn zeichnet Diese verweisen auf folgende Funktionen Nummer Funktion 1 Druckanschluss 2 und 4 Arbeitsanschluss 3 Entl ftungsanschluss 5 MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 5 1 2 Aufbau Magnetventil Typ 5470 Ger testeckdose Vorsteuerventil Typ 2506 Typ 6106 Handbet tigung Entl ftungsanschluss 3 Druckanschluss 1 Magnetspule Typ AC27 Typ 1054 Entl ftungsanschluss 3 gt Druckanschluss 1 gt Arbeitsanschluss 4 __4 Arbeitsanschluss 2 Typ 0470 5470 5 2 Wirkungsweisen C 5 3 2 Wege Ventil un In Ruhestellung Druckanschluss 1 135 geschlossen Arbeitsanschluss 2 n
26. nd die Umwelt entstehen gt Das Ger t dient ausschlie lich als 3 2 bzw 4 2 Wege Magnet ventil f r die laut Datenblatt des entsprechenden Typs zul ssigen Medien gt Mit einer sachgem angeschlossenen und montierten Ger testeck dose z B B rkert Typ 2506 bei Magnetventil Typ 5470 oder Typ 1054 bei Magnetventil Typ 0470 erf llt das Ger t die Schutzart IP65 nach DIN EN 60529 IEC 60529 gt Im explosionsgef hrdeten Bereich darf das Ger t nur entsprechend der Spezifikation auf dem separaten Ex Typschild eingesetzt werden F r den Einsatz muss die dem Ger t beiliegende Zusatzinformation mit Sicherheitshinweisen f r den Ex Bereich beachtet werden gt Ger te ohne separates Ex Typschild d rfen nicht im explosionsgef hr deten Bereich eingesetzt werden gt F r den Einsatz die in den Vertragsdokumenten dem Datenblatt und der Bedienungsanleitung spezifizierten zul ssigen Daten Betriebs und Einsatzbedingungen beachten gt Voraussetzungen f r den sicheren und einwandfreien Betrieb sind sachgem er Transport sachgem e Lagerung und Installation sowie sorgf ltige Bedienung und Instandhaltung gt Das Ger t nur bestimmungsgem einsetzen a 3 GRUNDLEGENDE SICHERHEITSHINWEISE Diese Sicherheitshinweise ber cksichtigen keine Zuf lligkeiten und Ereignisse die bei Montage Betrieb und Wartung auftreten k nnen A Verletzungsgefahr durch hohen Druck gt Vor dem L sen von Leitungen oder
27. nt en place Risque de br lures d incendie en fonctionnement continu d des surfaces d appareil br lantes Tenez les substances et les fluides facilement inflammables l cart de l appareil et ne touchez pas ce dernier mains nues Pour pr venir les blessures dommages mat riels veuillez tenir compte de ce qui suit gt Ne pas entreprendre de modifications internes ou externes sur l appareil et le prot ger contre tout actionnement involontaire gt Les travaux d installation et de maintenance doivent tre effectu s uni quement par des techniciens qualifi s et habilit s disposant de l outillage appropri gt Apr s une interruption de l alimentation lectrique ou pneumatique un red marrage d fini ou contr l du processus doit tre garanti gt Ne pas exposer le corps de la vanne des charges m caniques gt Respecter les r gles g n rales de la technique 4 HOMOLOGATIONS Le marquage d homologation appos sur les plaques signal tiques B rkert se rapporte aux produits B rkert Les appareils portant la marque e1 ont t homologu s au Service f d ral de la circulation auto mobile Kraftfahrtbundesamt sous le num ro e1 72 245 2006 96 5791 00 et seront mis en circulation avec la marque d homologation indiqu e 035791 Vous recevrez un extrait de l homologation l adresse cidessous B rkert Werke GmbH CQ Approval Management Christian B rkert Str 13 17 D 74653 Ingelfin
28. rotective conductor contact between the coil and housing is missing there is a danger of electric shock gt Always connect protective conductor gt Check electrical continuity between coil and housing 7 5 1 Connection of cable plug to the power supply Example Type 5470 Approved cable plug e g Type 2506 or other in accor dance with DIN ISO 175301 803 Sea Observe max tightening torque Fig 3 Connection of cable plug to the power supply Example type 5470 Tighten cable plug for authorized types see data sheet observing maximum torque 0 3 Nm Check that seal is fitted correctly Connect protective conductor and check electrical continuity between coil and housing s Tab 1 5 MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 NOTE If the cable plug is designed in such a way that the screw is pointing upwards insert a seal made of a material compatible with your process under the screw head Q Note the voltage and current type as specified on the type label Pesistor Test voltage Test current max 0 1 Q 12V 1A Tab 1 Test values protective conductor function Type 0470 5470 7 6 Actuating the pulse version The correct polarity is a prerequisite for the device to function Observe the markings on the coil surface Pulse duration at least 50 ms pin 1 pin 2 pin 1 pin 2
29. rr es la tension et la pression sont disponibles les tuyauteries sont propres la commande manuelle se trouve en position de repos La vanne ne s enclenche pas Cause possible court circuit ou coupure de la bobine noyau ou C ur encrass pression du fluide hors de la plage de pression autoris e La vanne ne se ferme pas Cause possible int rieur de la vanne encrasse 11 TRANSPORT STOCKAGE ELIMINATION REMARQUE Dommages dus au transport Les appareils insuffisamment prot g s peuvent tre endommag s pendant le transport gt Transporter l appareil l abri de l humidit et des impuret s et dans un emballage r sistant aux chocs gt Veiller ce que la temp rature de stockage ne se situe ni au dessus ni en dessous de la temp rature de stockage admissible gt Prot ger les interfaces lectriques de la bobine et les raccords pneumatiques avec des capuchons de protection pour viter tout endommagement Un mauvais stockage peut endommager l appareil gt Stocker l appareil au sec et l abri des poussi res gt Temp rature de stockage 40 C 80 C Dommages sur l environnement caus s par des pi ces d appareil contamin es par des fluides gt liminer l appareil et l emballage dans le respect de l environnement gt Respecter les prescriptions en mati re d limination des d chets et de protection de l environnement en vigueur Bf
30. s Zeigt im montierten Zustand die Schraube der Ger testeckdose nach oben f gen Sie eine Dichtung aus einem mit Ihrem Prozess kompatiblen Werkstoff unter dem Schraubenkopf ein Pin 1 Pin 2 Pin 1 Pin 2 Q Spannung und Stromart laut Typschild beachten Widerstand Pr fspannung Pr fstrom max 0 1 Q 12V 1A Tab 1 Prtifwerte Schutzleiterfunktion Steckerbelegung Auswirkung 1 3 i WW ie an Vorsteuerventil ge ffnet 2 3 S 1 4 WWC 1 2 i WW sn gt h Vorsteuerventil geschlossen 4 3 G 4 3 WWC gt 8 HANDBET TIGUNG 10 WARTUNG FEHLERBEHEBUNG Wenn f r den Einsatz des Ventils die Hinweise dieser Bedienungsan leitung beachtet werden arbeitet das Ventil wartungsfrei 10 1 Sicherheitshinweise T WARNUNG Verletzungsgefahr bei unsachgem en Wartungsarbeiten gt Die Wartung darf nur autorisiertes Fachpersonal mit geeignetem 0 Ruhestellun Werkzeug durchf hren g 1 Schaltstellung Verletzungsgefahr durch Stromschlag gt Vor Eingriffen in das Ger t oder die Anlage Spannung abschalten und vor Wiedereinschalten sichern Gefahr durch hohen Druck gt Vor dem L sen von Leitungen oder Ventilen den Druck abschalten Bild 4 Handbet tigung am Beispiel Typ 5470 und Leitungen entlasten Verletzungsgefahr durch ungewolltes Einschalten der Anlage und unkontrollierten Wiederanlauf 9 DEMONTAGE gt Anlage vor unbeabsichtigtem Bet tigen sichern
31. switched on the pipelines are clean the manual control is in the normal position Valve does not switch Possible causes short circuit or coil interrupted core or core area dirty medium pressure outside the permitted pressure range Valve does not close Possible causes inner compartment of the valve is dirty 11 TRANSPORTATION STORAGE DISPOSAL NOTE Transport damage Inadequately protected devices may be damaged during transportation gt Protect the device against moisture and dirt in shock resistant packaging during transportation gt Prevent the temperature from exceeding or dropping below the permitted storage temperature gt Protect the electrical interfaces of the coil and the pneumatic connections from damage by placing protective caps on them Incorrect storage may damage the device gt Store the device in a dry and dust free location gt Storage temperature 40 C 80 C Damage to the environment caused by device components contaminated with media gt Dispose of the device and packaging in an environmentally friendly manner gt Observe applicable disposal and environmental regulations E MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 burkert FLUID CONTROL SYSTEMS Type 0470 5470 3 2 or 4 2 way solenoid valve 3 2 bzw 4 2 Wege Magnetventil Electrovanne 3 2 ou 4 2 voies Operating Instructions
32. to the Type 0470 5470 Type 0470 5470 2 INTENDED USE Incorrect use of the solenoid valve Type 0470 5470 may be a hazard to people nearby equipment and the surrounding area gt The device is used exclusively as 3 2 or 4 2 way solenoid valve for the media permitted according to the data sheet of the correspond ing type Provided the cable plug is connected and installed correctly e g B rkert Type 2506 for Type 5470 or Type 1054 for Type 0470 the device satisfies degree of protection IP65 in accordance with DIN EN 60529 IEC 60529 In a hazardous area the device may be used only in accordance with the specification on the separate Ex type label For the use observe the additional information enclosed with the device with safety instructions for the EX area Devices without a separate Ex type label may not be used in a potentially explosive area Use according to the authorized data operating conditions and con ditions of use specified in the contract documents the data sheet and the operating instructions Correct transport correct storage and installation as well as careful use and maintenance are essential for reliable and problem free operation gt Use the device only for its intended purpose v v v v v i 3 BASIC SAFETY INSTRUCTIONS These safety instructions do not make allowance for any contin gencies and events which may arise during assembly operation and maintenance A
33. uss WARNUNG Verletzungsgefahr durch Stromschlag gt Vor Eingriffen in das System die elektrische Spannung abschalten und vor Wiedereinschalten sichern gt Die geltenden Unfallverh tungs und Sicherheitsbestimmungen f r elektrische Ger te beachten gt Achten Sie beim Verschrauben der Spule mit der Ger testeck dose auf einen einwandfreien Sitz der Dichtung Bei fehlendem Schutzleiterkontakt zwischen Spule und Geh use besteht die Gefahr eines Stromschlags gt Schutzleiter immer anschlie en gt Elektrischen Durchgang zwischen Spule und Geh use pr fen z 7 5 1 Anschluss der Ger testeckdose Beispiel Typ 5470 Zugelassene Ger testeckdose z B Typ 2506 oder andere nach DIN ISO 175301 803 Form C Flachdichtung Drehmoment beachten Bild 3 Anschluss der Ger testeckdose am Beispiel Typ 5470 gt Ger testeckdose zugelassene Typen siehe Datenblatt fest schrauben dabei maximales Drehmoment von 0 3 Nm beachten gt Korrekten Sitz der Dichtung berpr fen gt Schutzleiter anschlie en und elektrischen Durchgang zwischen Spule und Geh use pr fen s Tab 1 z MAN 1000010018 ML Version J Status RL released freigegeben printed 24 04 2015 Typ 0470 5470 HINWEIS 7 6 Ansteuerung Impulsausf hrung Richtige Polarit t ist Voraussetzung f r die Funktion des Ger ts Kennzeichnung auf der Spulenoberfl che beachten Impulsdauer mindestens 50 m
34. with a plug depending on the required operating principle Connection 2 Connection 4 Circuit function sealed open C open sealed D 7 4 Pneumatic connection WARNING Risk of injury from greatly accelerated device parts and uncon nected whiplashing compressed air hoses gt Before pressurizing the valve check that all screw connections and screw joints are tight and secure Installation position any preferably with solenoid system face up Before connecting Check whether hose lines are dirty and clean If required install a dirt filter upstream of the valve inlet lt 5 pm Pneumatic connection NOTE Risk of breakage gt Do not use coil as a lever arm gt Do not use a cylinder wrench to tighten screws Hold the device by hand on the housing and connect to the hose line Do not exceed the standard screw in depth Seal with PTFE tape or elastomer seal Observe allocation of the connections see Chapter 5 1 1 Connections page 4 gt Align hose lines 7 5 Electrical connection WARNING Risk of injury due to electrical shock gt Before reaching into the system switch off the electrical power supply and secure to prevent reactivation gt Observe applicable accident prevention and safety regulations for electrical equipment gt When screwing the coil onto the device socket make sure the seal is correctly seated If the p
35. ype 5470 9 D MONTAGE Le d montage s effectue dans le sens inverse du montage Affectation des connecteurs Effet 1 3 FG ae be Lee A Vanne pilote ouverte 2 3 1 4 FC sur broche 1 12 FG E e we 9 Vanne pilote ferm e 4 3 4 3 FC 35 10 MAINTENANCE D PANNAGE A condition de respecter les consignes de ce manuel d utilisation la vanne fonctionne sans n cessiter aucune maintenance 10 1 Consignes de s curit IN AVERTISSEMENT Risque de blessures d des travaux de maintenance non conformes gt La maintenance doit tre effectu e uniquement par un personnel qualifi et habilit disposant de l outillage appropri Risque de choc lectrique gt Avant d intervenir dans l appareil ou l installation coupez la tension et emp chez toute remise sous tension par inadvertance Danger d la haute pression gt Avant de desserrer les conduites ou les vannes couper la pression et purger l air des conduites Risque de blessures d la mise en marche involontaire de l installation et au red marrage non contr l gt Emp cher tout actionnement involontaire de l appareil gt Garantir un red marrage contr l apr s la maintenance 36 10 2 Pannes Lors d incidents v rifier que l appareil est install dans les r gles les raccordements lectrique et pneumatique ont t effectu s correctement l appareil n est pas endommag toutes les vis sont bien se