1. 13 LIFE TEST pushbutton This command is used to test th tub lif in function EMISSION 14 COLOUR TRACKING pushbutton Here the colour tracking is put into function 41 2 G1 BIAS selector Used to bias Gl to 50 or 70V in the CUT OFF function 16 Gl K SHORT REMOVE pushbutton This command is used to put into function the leakage or short removal in function REMOVE SHORTS 17 REMOVE SHORTS key This key is purposed for removing leakages and shorts between Gl and any cathode and between cathodes and the filament by pushing and releasing pushbutton Gl K SHORT REMOVE 16 If a short keeps on push this key several times 18 SHORTS key This key is used to sense leakages and shorts between the tube electrodes through following neon indicators 24 F and R G or for leakages or shorts between Gl and cathodes R G or B Gl for leakages or shorts between Gl and cathodes R G or B Gl and G2 for leakages between electrodes Gl and G2 In each case two neon lamps will light at once 19 HEATER VOLTAGE keys Page 6 02 2003 C R T Analyser Rejuvenator 4905 These keys are used to select the tube filament voltage between 6 3 V with a l A highest current or 12 V with an 0 5 A maximum current 02 2003 Page 7 C R T Analyser Rejuvenator 4905
2. SIDO OS Figure 2 1 Mains input cable 2 R G and B meters They will display current of cathodes in 22 EMISSION TEST f R rejuvenating swing T e T unction Colour areas enable state of tubes to be known At ESTORER GUN pointers will move according to the 3 he three commands B W G and B Are used to equalize the mitting currents of the tube cathodes 4 he ANODE connector voltage cable supplied with the instrument 2 POWER indicator It lights when the instrument is operating 6 Main switch This switch is used to start the equipment the neon POWER light 5 02 2003 It is used to apply voltage to the tube through the high as evidenced by Page 5 English 7 PF P 8 9 5 10 R U 11 RI C R T Analyser Rejuvenator 490B useholder rotecting the equipment in the event of an overload or hort circuit OCUS indicator It reports the right switching and operation of the FOCUS OCKET connector It is used to connect the adapter hose ESTORER START pushbutton sed to start the rejuvenation automatic cycle ESTORER ON indicator 12 R It reports the instrument is performing a rejuvenation ESTORER CURRENT selector It is used to select rejuvenating currents from 25 to 50 mA
3. Un autre cas est celui des tubes employ s dans des conditions normales des postes d t l vision m nagers Page 13 Francais Analyseur R g n rateur de T R C 4905 r glage normal du contraste et de la luminosit Leur cathode perd sa capacit d mission pour cause de la salet Cette salet provient des particules tr s fines poussi re se trouvant a l int rieur du tube m me apr s leur fabrication Ces particules d pos es statiquement sont attraites par les lectrodes les grilles diverses et la cathode ou elles adh rent Plus de particules se d poseront sur la cathode moins elle pourra mettre L image devient faible et sans d finition Ces tubes image peuvent tr r par s par une r g n ration r ussie a condition que la masse d oxyde de barium sur la cathode soit encore suffisante e Essai du temps de vie L essai du temps de vie peut tr ffectu a tout moment pourvu que la tension de coupure CUT OFF soit r gl e Appuyer sur la touche EMISSION TEST 22 Les aiguilles des instruments de mesure indiqueront la valeur du courant des cathodes Noter ces courants Pousser le bouton poussoir EMISSION LIFE TEST 13 et le retenir ainsi quelques secondes jusqu ce que les aiguilles des galvanom tres s immobilisent Noter cett seconde lecture de courant La variation entre ces courants donne une notio
4. tout le temps de l essai Les aiguilles des mesureurs d fl chiront a peu pres vers le milieu de 1 chelle Noter visuellement le mesureur a lecture la plus haute Tourner alors a droite les commandes COLOUR TRACKING 3 des deux commandes restantes une par une jusqu a galer la lecture la plus haute Si on l obtient cela signifie que la diff rence de courant entre les trois cathodes se trouve dans les limites admissibles Au cas contraire la diff rence de courant de la des cathode s plus basse s est plus grand qu cell admissible le tube devra tre r g n r 02 2003 Page 15 Francais Analyseur R g n rateur de T R C 490B Page 16 02 2003 Analyseur R g n rateur de T R C 490B 5 ENTRETIEN 5 1 Divers L entretien normal que doit effectuer l usager est circonscrit au nettoyage de l instrument et remplacer les fusibles L rest des op rations d entretien r paration et calibrage ne sera effectu que par le service technique PROMAX ou les agents agr es Pour ouvrir l appareil d visser les 6 vis du panneau on pourra retirer le ch ssis de la valise 02 2003 Page 17 Fran ais Analyseur R g n rateur de T R C 490B Page 18 02 2003
5. Echelle de mesur 0 1 6 mA mesure R G et B simultan ment Bandes couleur Vert GOOD rouge BAD R g n ration Courant 25 ou 50 mA par s lection Cycle Environ 70 5 D but du cycle Manuel Tubes couleur S lection R G ou B Tension Anode 600 V approx Fonctions additionnelles Fuites et courts circuits Essai d mission Essai du temps de vie Essai Gl VARIABLE Essai TRACKING 02 2003 Page 1 Francais Analyseur R g n rateur de T R C 4905 Alimentation Tension de secteur CA 220 V 10 50 60 Hz Adaptable sur 110 125 ou 240 V Consommation 35W Caract ristiques m caniques Genre mallette avec place r serv e pour 16 adapteurs Dimensions L 420 x H 340 x Pr 145 mm Poids 4 85 Kg Accessoires compris Manuel d utilisation Fusible de recharge 6 socles adapteurs pour TRC divers C ble d adapteurs CC O11 Cable d anode CC 026 Liste d adapteurs TRC Adapteurs livr s A6 A7 A9 A10 All Adapteurs Optionnels A O universel Fa onable par l utilisateur au moyen des files de connexion Al A2 A3 A12 A16 A17 A18 A20 A21 A22 A23 A24 A26 A27 Jeu d adapteurs 006 2899 2 02 2003 Analyseur R g n rateur de T R C 490B 2 INSTALLATION 2 1 Alimentation Cet appareil est livr d usine pour tre aliment sur CA 220 V 50 60 Hz Avant de brancher 1 instrument LA v rifier que la
6. Tecla REMOVE SHORTS Con esta tecla se pueden eliminar las fugas o cruces entre Gl y cualquiera de los c todos y entre los c todos y el filamento apretando y soltando el pulsador 16 Gl K SHORT REMOVE Si persiste el cruce pulsar varias veces Tecla SHORTS Con esta tecla se detectan las fugas o cortocircuitos entre los electrodos del tubo mediante los indicadores de ne n 24 F y R G B para fugas o cruces entre el filamento y los c todos R B E Gl para las fugas o cruces entre Gl y los c todos R Ba Gl y G2 para las fugas entre los electrodos Gl y G2 en cada caso se iluminan dos neones a la vez Tecla 6 3 V 12 V Pagina 6 02 2003 Analizador regenerador de T R C 03 Con estas teclas se selecciona la tensi n de filamento del tubo entre 6 3 V con una corriente m xima de 1 A 12 V con una corriente de intensidad m xima de 0 5 A 02 2003 P gina 7 25 26 27 Analizador regenerador de T R C 490B Tecla Gl VARIABLE Esta tecla permite ajustar la tensi n de Gl entr 100 V y con lo qu s pued trazar la curva caracteristica tensi n corriente del tubo mediante el mando Gl VARIABLE de 100 a 0 V y las indicaciones de corriente de haz le das en los medidores 2 Tecla CUT OFF Con esta tecla se puede llevar el tubo al punto de corte con el mando 2
7. Voyants accusant la pr sence de fuites ou courts circuits ntre des lectrodes du tube dans la fonction SHORTS E CUT OFF VOLTAGI S lecteur de tension de G2 dans la fonction CUT OFF 21 CUT OFF Sl GI T Cette commande r gle la tension de G2 dans la fonction CUT OFF 21 G1 VOLTAGI GI Cette commande r gle la polarisation de Gl dans la fonction VARIABLE 20 Page 8 02 2003 Analyseur R g n rateur d 02 2003 R Ce 490B Page 9 Francais Analyseur R g n rateur de T R C 490B Page 10 02 2003 Analyseur R g n rateur de T R C 490B 4 METHODE D UTILISATION 4 1 Pr paration Avant de brancher 1 appareil au secteur tourner touches les commandes rotatoires 3 26 et 27 tout a gauche les touches du clavier 17 23 rel ch es hors fonction et les commutateurs 12 15 et 25 pouss s gauche Au besoin r gler ro m canique des appareils de mesure 4 2 Utilisation 1 Brancher 1 instrument au secteur 2 Choisir l adapteur du TRC appropri voir table des adapteurs et le raccorder au cable d adapteurs 3 Brancher le cable a son connecteur 9 SOCKET 4 Chercher dans la table d adapteurs la tension de filament ajust e au TRC et engager la touche de tension de filament correspondant 19 5 Brancher la tension de polarisation de G
8. 1 Appuyer sur la touche 23 de la cathode que l on d sire r g n rer rouge si la cathode est rouge verte si la cathod st vert t 51898 si la cathode est bleue S lectionner le courant de r g n ration par le commutateur 12 Dans 1 ensemble il est conseillable de commencer le proc d de r g n ration par un courant de 25 mA commande a gauche et ne r p ter l op ration 50 mA commande a droite que lorsqu on ne peut am liorer le courant d mission ou que celui ci est trop faible Page 12 02 2003 Analyseur R g n rateur de T R C 490B Brancher la pointe du connecteur m le du c ble de H T au connecteur femelle 4 du tableau l autre bout ventouse au connecteur T H T du TRC d charg au pr alable Le proc d de r g n ration d marre au moyen du bouton poussoir RESTORER START 10 Le TA 903B chauffe tout d abord le tube image et commence ensuite la r g n ration Ce proc d st enti rement automatique et dure quelques 70 secondes L voyant de r g n ration RESTORER ON 11 demeure allum tout le temps de r g n ration il s teint lorsque celle ci est termin L intensit du courant de r g n ration peut tre suivie l instrument de la cathode correspondante 2 R G ou B Le proc d de r g n ration mis en marche par le bouton poussoir RESTORER START 10 ne peut tre interrompu
9. tension d alimentation est conforme L quipement s adapte par voie interne aux tensions de secteur de 110 125 220 et 240 V CA 50 60 Hz Pour brancher l appareil sur d autres tensions de secteur voir ci apr s ATTENTION Avant d effectuer les op rations suivantes d brancher l quipement du secteur Enlever les 6 vis de fixation du coffr ch ssis Ensuite passer la prise du d alimentation la borne de la tension choisi t d gager 1 transformateur 110 125 200 240 V et changer le fusible au besoin Figure 1 Fusible 5 x 20 mm de pour 110 125 V pour 220 240 V LA L instrument peut tomber en panne par la n gligence de ces instructions 02 2003 Page 3 Fran ais Analyseur R g n rateur de T R C 490B Page 4 02 2003 Analyseur R g n rateur de T R C 490B 3 DESCRIPTION DES COMMANDES Tableau SIDO BS avant Figure 2 1 C ble d entr e de secteur 2 Appareils de mesure R Get B Ils signalent les courants des cathodes a EMISSION TEST 22 Les secteurs colori s permettent de conna tre l tat des tubes A RESTORER GUN les aiguilles se d placent en suivant le rythme de la r g n ration 3 Les trois commandes B W G et B servent galiser les courants
10. AC 50 60 Hz Antes de conectar el instrumento asegurarse de que la tensi n de alimentaci n es correcta El equipo es adaptable internamente a tensiones de red de 110 125 220 y 240 V AC 50 60 Hz Para conectar el aparato a otras tensiones de red proceder como sigue ATENCION Antes d fectuar las Siguientes operaciones desconectar el equipo de la red Quitar los 6 tornillos de sujeci n de la maleta y sacar el chasis Una vez fuera de la maleta el chasis se cambiara la toma del transformador de alimentaci n al terminal correspondiente a la tensi n escogida 110 125 200 240 V cambiando si fuese necesario el fusible Figura 1 El fusible ser de tipo 5 x 20 mm y de para 110 125 V para 220 240 V El incumplimiento de estas instrucciones podr a da ar el instrumento 02 2003 P gina 3 Analizador regenerador de T R C 490B P gina 4 02 2003 Analizador regenerador de T R C 03 3 INSTRUCCIONES DE FUNCIONAMIENTO Panel frontal SIDO OS Figura 2 1 Cable de entrada de red 2 Medidores R Gy B Indican la corriente de los c todos en 22 EM tubos y en R ISSI ON E EST ritmo de la regeneraci n 3 Los tres mandos B W G y B sirven para igualar los sectores de colores permiten conocer el estado de 105 ESTORER GUN
11. B to be nearly the same After rejuvenating colour tubes do revise the black and grey adjustment and do compensate it if needed A comment follows over cathodic tube rejuvenation In order to decide whether it is worth to rejuvenate a CRT it will be helpful to know conditions in which that tube has been used Picture tubes that work from the first day at full intensity highest contrast and brightness and a long time a day as well once they have lost brightness they will not yield the desirable result even after several rejuvenations This is the case for instance of TV game picture tubes These tubes may b rejuvenated only in very few cases because their cathodes are short of barium oxide Another event is the one of tubes working in normal conditions in household TV sets standard contrast and brightness adjustment In these sets the cathode losses its emitting capacity due to dirt Dirt is caused by fine dust particles still into the glass tube after leaving its manufacture process These particles statically deposited are attracted by electrodes the several grids and the cathode where they adhere The more particles are depositing on the cathode th less mission will be supplied Picture Page 13 English C R T Analyser Rejuvenator 4905 becomes weak and undefined These picture tubes may be repaired by a rejuvenation that gives a good result
12. In function SHORTS these light lamps will point out leakages and shorts between tube electrodes Voltage selector of G2 in function CUT OFF 21 This control regulates voltage of G2 in function CUT OFF 20 G1 VARIABLE key 21 CUT OFF key with 50 or 70V range 22 EMISSION TEST key life of the tube 23 RESTORE GUN keys 24 SHORTS indicators 25 CUT OFF VOLTAGE 26 CUT OFF SET 240 27 G1 VOLTAGE It regulates the bias of Gl in function VARIABLE 20 Page 8 02 2003 C R T Analyser Rejuvenator 4905 02 2003 Page 9 C R T Analyser Rejuvenator 4905 4 HOW TO USE 4 1 Preparation Before to connect the unit to mains turn all rotating knobs 3 26 and 27 to the left stop release keys 17 to 23 disabled and set switches 12 15 and 25 to the left hand position If required set the mechanical zero of meters 4 2 Use 1 Connect the instrument to mains 2 Select the suitable CRT adapter see adapter table and plug it into the socket adapter cable 3 Plug the cable into its connector SOCKET 9 4 Read the suitable CRT filament voltage see adapter table and push the filament voltage key related with 19 5 Connect the bias voltage of Gl BIAS through switch 15 at 50V 6 Select cut off voltage of G2 CUT OFF Set the voltage switch 25 at 300V 7 Switch off the TV set or monitor from mains and unloa
13. del mas alto De conseguirlo significara que la diferencia de corriente entre los tres c todos esta comprendido den tro de los limites admisibles De no conseguirlo significar que la diferencia de corriente del c todo s mas bajo s es m s grande de lo admisible y se procedera a su Pagina 14 regeneracion 02 2003 Analizador regenerador de T R C 03 02 2003 P gina 15 Analizador regenerador de T R C 4905 5 MANTENIMIENTO 5 1 Generalidades El mantenimiento normal a efectuar por el usuario consiste en la limpieza del instrumento sustituci n de los fusibles y eventualmente reajust del regenerador de acuerdo con las instrucciones detalladas en el apartado siguiente Todas las dem s operaciones de mantenimiento reparaci n y calibraci n deben ser fectuadas por el servicio t cnico de PROMAX agentes autorizados Para abrir el aparato destornillar los 6 tornillos del panel podr retirarse el chasis de la maleta Pagina 16 02 2003 Analizador regenerador de T R C 03 02 2003 P gina 17 C R T Analyser Rejuvenator 4905 TABLE OF CONTENTS C R T Analyser Rejuvenator 4905 C R T Analyser Rejuvenator 4905 C R T ANALYSER REJUVENATOR 490B 4 GENERAL 1 1 Description The 490B has been intended for checking and rejuvenating cathodic ray tubes CRT television sets and
14. las agujas se desplazan siguiendo el las corrientes de emisi n de los c todos del tubo 4 El conector ANODE Sirve para aplicar la tensi n al tubo mediante el cable con ventosa que se suministra con el aparato 5 POWER 6 Interruptor Indica que el aparato est en funcionamiento Sirve para la puesta en marcha del aparato indicada por el ne n 02 2003 5 POWI 2 ER E P gina 5 Analizador regenerador de T R C 4905 Portafusible Protege el aparato en caso de sobrecarga o cortocircuito Ne n FOCUS Indica el correcto conexionado y funcionamiento del FOCO Connector SOCKET Sirve para conectar la manguera de los adaptadores RESTORER START Sirve para dar origen al ciclo autom tico de regeneraci n RESTORER ON Indica que el aparato esta regenerando RESTORER CURRENT E Selecciona las corrientes de regeneraci n de 25 a 50 mA LIFE TEST 14 71 18 19 Sirve para la prueba de vida del tubo en la funci n EMISSION COLOUR TRACKING Pone en funcionamiento la funci n COLOUR TRACKING G1 BIAS Sirve para polarizar Gl a 50 70 V en la funci n CUT OFF Gl K SHORT REMOVE Sirve para poner en funcionamiento el circuito de eliminaci n de fugas o cruces en la funci n REMOVE SHORTS
15. 4905 ANALIZADOR REGENERADOR DE T R C C R T ANALYSER REJUVENATOR ANALYSEUR REGENERATEUR DE T R C 11085 NOTAS SOBRE SEGURIDAD Antes de manipular el equipo leer el manual de instrucciones y muy especialmente el apartado PRESCRIPCIONES DE SEGURIDAD El s mbolo sobre el equipo significa CONSULTAR EL MANUAL DE INSTRUCCIONES En este manual puede aparecer tambi n como s mbolo de advertencia o precauci n Recuadros de ADVERTENCIAS Y PRECAUCIONES pueden aparecer a lo largo de este manual para evitar riesgos de accidentes a personas o da os al equipo u otras propiedades SAFETY NOTES Read the instruction manual before using the equipment mainly SAFETY RULES paragraph The symbol A on the equipment means SEE USER S MANUAL In this manual may also appear as a Caution or Warning symbol Warning and Caution statements may appear in this manual to avoid injury hazard or damage to this product or other property REMARQUES A PROPOS DE LA SECURITE Avant de manipuler l appareil lire le manuel d utilisation et plus particuli rement le paragraphe PRESCRIPTIONS DE S CURIT Le symbole AN sur l appareil signifie CONSULTER LE MANUEL D UTILISATION Dans ce manuel il peut galement apparaitre comme symbole d avertissement ou de pr caution Des encadr s AVERTISSEMENTS ET PRECAUTIONS peuvent apparaitre dans ce manuel pour Sviter des risques d accidents affectant des person
16. 6 CUT OFF SET y el selector 25 300 600 V el selector 15 Gl BIAS permite polarizar el tubo con 50 70 V Despu s de llevar el tubo al punto de corte el pulsador 14 COLOUR TRACKING permit fectuar el balanceo de las corrientes de los c todos para igualar las corrientes de emisi n mediante los tres mandos 3 B W R G y B dentro de un margen limitado Tecla EMISSION TEST Con esta tecla se mide la corriente de emisi n de los tres c todos a la vez en el punto de corte por lo cual no se pueden modificar los ajustes efectuados anteriormente en la funci n 21 CUT OFF Mediante el pulsador 13 LIFE TEST se puede apreciar la variaci n de las corrientes de los c todos al disminuir la tensi n del filamento lo cual da una idea aproximada del tiempo de vida del tubo Teclas RESTORE GUN Las teclas B W R G B seleccionan el c todo que se desee regenerar el selector 12 RESTORER CURRENT permit scoger dos intensidades de regeneraci n de 25 50 mA El pulsador 10 RESTORER START da origen al ciclo de regeneraci n indicado por el 11 LED RESTORER ON SHORTS Indican la presencia de fugas o cruces entr lectrodos del ubo en la funci n SHORTS E elector de tensi n de G2 en la funci n 21 CUT OFF 1 1 t CUT OFF V
17. G2 Margen de variaci n 30 V a 600 V variable en 2 escalas Medida de corriente de emisi n Corriente de emisi n 0 a 1 6 mA simultanea R G y B Franjas de colores Verde GOOD rojo BAD Regeneraci n Corriente 25 50 mA seleccionable Ciclos 70 s aprox Inicio de ciclo Manual Tubos de color Selecci n R B Tensi n nodo 600 V aprox Funciones adicionales Fugas y cortocircuitos Prueba de emisi n Prueba de Esperanza de vida Curva de emisi n Prueba de Balance de los c todos 02 2003 P gina 1 Analizador regenerador de T R C 4905 Alimentaci n Tensi n de red 220 V AC 10 50 60 Hz Adaptable a 110 125 240 V Consumo 35W Caracter sticas mec nicas Tipo de maleta con espacio reservado para 16 adaptadores Dimensiones A 420 x Al 340 x Pr 145 mm Peso 4 85 Kg Accesorios incluidos Manual de instrucciones Fusible de repuesto 6 z calos adaptadores a distintos TRC Cable adaptadores CC 011 Cable de nodo CC 026 Lista de TRC Adaptadores Adaptadores suministrados A6 A7 A8 A9 A10 All Adaptadores Opcionales A 0 universal personalizable mediante hilos de conexi n Al A2 A3 A12 A14 A16 A17 A18 A20 A21 A22 A23 A24 A26 A27 Juego adaptadores 006 P gina 2 02 2003 Analizador regenerador de T R C 03B 2 INSTALACI N 2 1 Alimentaci n Este aparato viene conectado de f brica para ser alimentado a 220 V
18. OLTAGI S C T UT OFF S Regula la tensi n de G2 en la funci n 21 CUT OFF G1 VOLTAGI GI Regula la polarizaci n de Gl en la funci n 20 VARIABLE Pagina 8 02 2003 Analizador regenerador de T R C 03 02 2003 P gina 9 Analizador regenerador de T R C 4905 4 FORMA DE UTILIZACI N 4 1 Preparaci n Antes de conectar el aparato a la red colocar todos los mandos del panel al tope izquierdo 3 26 v 27 las teclas de la botonera 17 a 23 en descanso no activadas y los conmutadores 12 15 y 25 en la posici n izquierda Ajustar si fuese necesario el cero mec nico de los medidores 4 2 Utilizaci n 1 Conectar el instrumento a la red 2 Escoger el adaptador de TRC adecuado en la tabla de adaptadores y conectarlo al cable adaptador de z calos 3 Conectar el cable a su conector 9 SOCKET 4 Consultar la tensi n de filamento apropiada al TRC en la tabla de adaptadores y pulsar la tecla de tensi n filamento 19 correspondiente IAS mediante el 5 Conectar la tensi n de polarizaci n de G conmutador 15 a 50 V 6 Seleccionar la tensi n de corte de G2 CUT OFF Colocar el conmutador de tensi n 25 en 300V 7 Desconectar el televisor 6 monitor de la red y descargar el MAT del tubo varias veces si fuese necesario 8 Desconectar el z calo del TRC y conectar el cabl
19. Through this key Gl variable voltage can be selected In this way the voltage current specific curve of the tube can be plotted through the Gl VARIABLE control 27 between 100 and 0 V and beam current indications be read in meter 2 This key allows the tube to be set at the cut off point by turning control 26 CUT OFF SET and selector 25 300V or 600V The Gl BIAS selector is used for biasing the tube After having set the tube at the cut off point the COLOUR TRACKING pushbutton 14 is used to perform current balance between cathodes in order to equalize emitting currents through controls 3 B W R G and B within a restricted This key is used for measuring the emission current of the three cathodes at the same time at the cut off point this means that settings performed previously in function 21 C T E UT OFF cannot be modified hrough pushbutton 13 LIFE TEST variation of cathode urrents can be valuated when lessening the filament voltage This will give an approximate idea of the expected Keys B W R G or B will select the cathode to be rejuvenated The selector 12 RESTORER GUN permits two rejuvenating levels to be chosen whether 25 or 50 mA Pushbutton 10 RESTORER START will give rise to the rejuvenating cycle stated by the LED RESTORER ON 11
20. d mission des cathodes du tube 4 Connecteur ANODE Par ce connecteur la tension est appliqu e au tube au moyen du c ble ventouse fourni avec l appareil 5 POW E ER E Sig nale le fonctionnement de 1 appareil 6 Interrupteur 02 2003 Mise en marche de 1 appareil signal e par le voyant POWI 51 Fl Page 5 Fran ais Analyseur R g n rateur de T R C 4905 Portefusible Protection de l appareil en cas de surcharge ou court Voyant n on FOCUS Ce voyant signale la mise en circuit et la marche juste de Connecteur SOCK GI T mploy pour y brancher le c ble des adapteurs ESTORER START ise en marche du cycle automatique de r g n ration voyant signale que la r g n ration est en cours ESTORER CURRENT S lecteur des courants de r g n ration de 25 a 50 mA Essai de la dur e du tube dans la fonction EMISSION COLOUR TRACKING Mise en marche de la fonction COLOUR TRACKING accord de Polarisation de Gl 50 ou 70 V dans la fonction CUT OFF Gl K SHORT REMOVE Cette commande met en marche le circuit suppresseur de fuites ou courts circuits dans la fonction REMOVE SHORTS Touche REMOVE SHORTS Cette commande est employ e pour supprimer les fuites ou courts circui
21. d the tube EHT several times if required 8 Switch off the CRT socket and plug the connection cable into the socket adapter already connected to the CRT 9 Start the 490B through switch 6 Function indicator 5 will light and the CRT will heat up 4 3 CRT test a Setting the CUT OFF Push key CUT OFF 21 and slowly turn the CUT OFF SET control 26 Watch carefully at pointers of the thr meters As soon as the first pointer reaches the CUT OFF indication at the scale stop turning control CUT OFF SET 26 Now the cut off current of the CRT is set This setting should not be altered in any other measurements In the case that pointers do not reach the CUT OFF indication at the scale move selector 25 to the 600V position knob to the right hand With black and white tubes watch at the B W R meter only Page 10 02 2003 C R T Analyser Rejuvenator 4905 02 2003 Page 11 C R T Analyser Rejuvenator 4905 b Leakage test Push key SHORTS 18 Look whether some leakage or short indicator gets lighting 24 If ther ar leakages or shorts lamps relative to the affected electrodes will light For instance if F and G are lighting leakages or shorts are between the filament and the green cathode Should any lamp 24 light then push key REMOVE Gl SHORT 17 and next to push the Gl F SHORT pushbutton 16 Now unload of a capacitor is taking place between catho
22. des and the CRT to eliminate leakages or shorts After that get back to position SHORTS 18 so as to verify whether some lamp is still lighting If so repeat the same procedure but awaiting some 10 seconds to let the capacitor get loaded c Emission test Push key EMISSION TEST 22 Pointers will show the emitting value of cathodes Colour picture tubes in accurate state will give current values between nearly 0 8 and 1 6 mA black and whit ones will give them from 0 5 to 1 mA Serviceable tubes with a good rejuvenating result will afford between 0 3 and 0 8 mA B W 0 3 to 0 5 mA On the contrary lasting results usually are not achieved when rejuvenating cathodes yielding up below 0 3 mA B W 0 2 mA because they are In too exhausted emission mode lamp FOCUS 8 should light telling the right operation of that electrode d Rejuvenation These are the procedures how to rejuvenate a CRT La Page 12 Push key 23 of that cathode to be rejuvenated the red key for the red cathode th green on for the green cathode and the blue one for the blue cathode Select the rejuvenating current through selector 12 Usually it is advisable to begin the rejuvenating process at a 25 mA current knob to the left hand Only if there is no improvement of the emitting current or the increase is very low then repeat the rejuvenating pr
23. e de conexi n con el adaptador del z calo ya conectado al TRC 9 Poner en marcha el TA 903B mediante el interruptor 6 El indicador de funcionamiento SJ se encender y el TRC comenzar a calentarse 4 3 Prueba del TRC a Ajuste del CUT OFF Apretar la tecla CUT OFF 21 girar lentamente el mando CUT OFF SET 26 Observar atentamente las agujas de 108 tres medidores Cuando la primera de las agujas llegue a la indicaci n CUT OFF de la escala parar de girar el mando 26 CUT OFF SET En este momento quedar ajustada la corriente de corte de tubo TRC Este ajuste no debe de alterars n todas la dem s mediciones En caso de no conseguir que las agujas P gina 10 02 2003 Analizador regenerador de T R C 03B lleguen a la indicaci n CUT OFF de la escala pasar el conmutador 25 a la posici n 600V bot n a la derecha En los tubos de blanco y negro observar solamente el medidor B W R b Prueba de fugas Apretar la tecla 18 SHORTS Observar si se ilumina alg n indicador de fugas 6 cortocircuitos 24 Caso de existir fugas cortocircuitos se iluminar n las lamparitas correspondientes a los electrodos afectados Por ejemplo si se iluminan F y G las fugas 6 cortocircuitos son entre filamento y c todo verde En el caso de que se iluminar alguna lamparita 24 apretar la tecla 17 REMOVE Gl SHORT Seguidament apretar l pulsador 16 Gl F SHORT En este momento se
24. ente no obstante en algunos TRC puede ocurrir que permanezca igual 6 que descienda ligeramente Esto desde luego no significa que el proceso regenerador no haya dado resultado El proceso d regeneraci n pued teners qu repetir varias veces en tubos muy agotados En tubos de color es muy importante que los valores de emisi n de los 3 sistemas R G B sean aproximadamente iguales 3 Despu s de regenerar tubos de color debe revisarse el ajuste del negro y de grises y eventualmente compensarlo 4 Comentario sobre la regeneraci n de tubos de rayos cat dicos Para decidir si vale la pena regenerar un tubo de rayos cat dicos es interesante conocer las condiciones en que se ha utilizado el tubo Los tubos de imagen que funcionan desde el primer d a a plena intensidad contraste y luminosidad m ximos y tambi n durante largo tiempo al d a cuando pierden luminosidad aun despu s de varias regeneraciones posiblemente no dar n el resultado apetecido ejemplo Pagina 12 02 2003 Analizador regenerador de T R C 03B los tubos de imagen de juegos televisivos En raros casos es posibl regenerar stos tubos puesto que su c todo carece pr cticamente de masa de xido de bario Otro caso ocurre con tubos empleados en las condiciones normales de los televisores dom sticos ajuste normal de contrate y luminosidad En ellos el c todo pierde su capacidad emisora por causa de la s
25. i n a una corriente de 25 mA bot n a la izquierda y solamente en caso de no conseguir mejora de la corriente de emisi n conseguir un aumento muy 02 2003 P gina 11 Analizador regenerador de T R C 4905 peque o repetir el proceso de regeneraci n a 50 mA bot n a la derecha Conectar la punta del conector macho del cable H T en el conector hembra 4 del panel y el otro ext remo ventosa en el conector M A T del tubo TRC previamente descargado El proceso de regeneraci n se pone en marcha mediante el pulsador 10 RESTORER START El TA 903B primero calienta el tubo de imagen y luego inicia la regeneraci n El proceso regenerador es totalmente autom tico y dura unos 70 segundos El indicador de regeneraci n 11 RESTORER ON est encendido durante todo el tiempo del proceso y se apaga una vez finalizada la regeneraci n La intensidad de la corrient d regeneraci n puede observarse en el instrumento del c todo correspondiente 2 R GOB Si se pone en marcha el proceso de regeneraci n mediante el pulsador 10 RESTORER START no puede ser interrumpido salvo que se desconect 1 aparato mediante el interruptor 5 POWER GI 2 Despu s de una regeneraci n conviene medir nuevamente la emisi n para comprobar una posible variaci n Por regla general el valor de la emisi n se eleva ligeram
26. l BIAS par le commutateur 15 8 50 V 6 S lectionner la tension de coupure de G2 CUT OFF Placer le commutateur de tension 25 sur 300V 7 D brancher le poste de t l vision ou le moniteur du secteur et d charger la THT du tube au besoin plusieurs fois 8 D brancher la socle du TRC et brancher le c ble de raccordement a 1 adapteur d j reli au TRC 9 Mettre le TA 903B en marche par l interrupteur 6 Le voyant de fonctionnement 5 s allumera et le TRC commencera s chauffer 4 3 Essai du TRC a R glage du CUT OFF Appuyer sur la touche CUT OFF 21 et tourner lentement la commande CUT OFF SET 26 Surveiller les aiguilles des trois instruments de mesure Aussit t que la premi re aiguille atteint 1 indication CUT OFF de 1 chelle arr ter de tourner la commande CUT OFF SET 26 A ce moment le courant de coupure du TRC est r gl Ce r glage ne doit pas tre chang dans aucune autre mesure Si les aiguilles ne peuvent pas 02 2003 Page 11 Fran ais Analyseur R g n rateur de T R C 4905 atteindre l indication CUT OFF d l chelle passer le commutateur 25 18 position 600V commande droite Dans les tubes blanc et noir ne suivre que le mesureur B W Re Essai de fuites Appuyer sur la touche SHORTS 18 Voir si quelque voyant de fuites ou courts circuits 24 s allume En cas de fuites ou courts circuits les vo
27. moins que l on d branche l appareil par 1 interrupteur POWER 5 Apr s une r g n ration il est util d mesurer l mission une fois de plus pour d celer une possible variation Dans l ensemble la valeur de 1 mission augment l g rement Cependant dans certains TRC elle peut demeurer gale ou descendre un peu Ceci ne signifie pas que le proc d r g n rateur n est pas abouti Dans des tubes tr s puis s il peut tre n cessaire de reprendre plusieurs fois la r g n ration Dans les tubes couleur il est essentiel que les valeurs des 3 syst mes R G B soient peu pr s gales Apr s avoir r g n r des tubes couleur v rifier le r glage du noir et des gris et le compenser au besoin Commentaire sur la r g n ration des tubes rayons cathodiques Pour d cider s il y a avantage de r g n rer un TRC il est utile de connaitre les conditions dans lesquelles c tube a t employ Soit les tubes image marchant d s 1 premier jour a pleine intensit contraste et luminosit au maximum et longtemps ans la journ e Leur luminosit perdue ils ne r ussiront certainement pas de bons r sultats m me apr s plusieurs r g n rations Cet exemple peut tre constat dans des tubes de jeux t l visifs Il est rare de pouvoir r g n rer ces tubes car leur cathode est virtuellement d pourvue d oxyde de barium
28. monitors With this instrument and likely to repair current of cathodes at once and to rejuvenat 1 2 Specifications Heater Selectable voltages Gl Bias Voltage fixed selectable Voltage variable G2 Bias CUT OFF adjustment ranges Emission test Measurement range Colour indication bands Rejuvenation Current Cycle duration Start cycle Colour tubes Anode voltage Additional functions Leakage or short Emission test Life expectance test G1 VARIABLE test TRACKING test 02 2003 of both the user will be able to find out leakages or to plot very cathode separately shorts colour black and white measuring the RGB voltage current features 6 3 V 1 max 12 V 0 5 A max 50 V and 70 V CUT OFF 100 V to 0 V G1 VARIABLE 21 30 V to 600 V variable in 2 0 to 1 6 mA R G or B simultaneous measuring Green GOOD red BAD 25 or 50 mA selectable 70 5 approx Manually R G or B selection 600 V approx Page 1 English C R T Analyser Rejuvenator 4905 Power supply Mains voltage AC 220 V 10 50 60 Hz 110 125 or 240 V internally selectable Consumption 35 W Mechanical features Suitcase format for carrying and ready use with room for 16 adapter Dimensions W 420 x H 340 x Pr 145 mm Weight 4 85 kg Included accessories Instruction manual Space fuse 6 adapters s
29. n sur 1 espoir de vie du tube image Pour des variations de quelques 10 divisions p ex de 1 00 a 0 80 mA le temps de vi sera inf rieur a1 an Pour des variations de quelques 5 divisions p ex de 1 00 a 0 90 mA la vie du tube peut tre de 1 an environ Pour des variations de 2 a 3 divisions le temps de vie a sp rer est de 1 a 2 ans Si la lecture ne descend pas le tube peut tre consid r en bon tat neuf ou presque nulle Plus il y aura de diff renc ntre les deux lectures et plus rapide sera la chute de courant plus court sera le temps sp r de vie du tube image Dans un tube neuf la diff renc ntre courants sera presque nulle f Essai Gl VARIABLE Pousser la touche Gl VARIABLE 20 Dans cette fonction la tension de Gl d pend de la position de la commande Gl Page 14 02 2003 Analyseur R g n rateur de T R C 490B VARIABLE 27 allant de 100V OV On peut ainsi tracer la courbe caract ristique la tension et le courant des trois cathodes en m me temps en fonction de la tension de Gl 1 21 in 1 0 0 8 0 6 0 4 0 2 0 0 70 60 50 40 30 20 10 0 Vo in V Figure 3 g Essai TRACKING Appuyer sur la touche CUT OFF 21 Appuyer ensuite sur le bouton poussoir COLOUR TRACKING 14 et le maintenir ainsi
30. nes ou des dommages l appareil ou a d autres biens SUMARIO CONTENTS SOMMATRE Manual espa ol 9 98 9 9 9 9 9 9 9 9 9 9 9 98 9 9 9 9 9 9 9 9 9 9 9 9 0 0 9 9 9 9 9 9 9 9 9 9 9 5 E 2 English manual 9 98 9 9 9 98 9 9 9 9 9 9 9 98 9 9 9 9 9 9 98 9 9 9 9 9 9 0 9 9 9 9 9 9 9 0 9 9 5 Manuel fran ais 98 98 9 9 9 9 9 9 9 9 9 9 9 9 9 98 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 e 9 9 9 9 Fran ais Analizador regenerador de T R C 4905 NDICE INSTALACI Analizador regenerador de T R C 490B Analizador regenerador de T R C 03 ANALIZADOR REGENERADOR DE T R C 490B 1 GENERALIDADES 1 1 Descripci n El 490B ha sido dise ado para la verificaci n y regeneraci n de los tubos de rayos cat dicos TRC de televisi n o monitores tanto para blanco y negro como de color Permite conocer y eventualmente reparar las fugas o cruces entre electrodos medir simult neamente la corriente de los c todos RGB trazar las caracter sticas tensi n corriente y regenerar los c todos independientement 1 2 Especificaciones Filamento Tensiones seleccionables 673 V 1 A m x 12 V 0 5 A m x Polarizaci n Gl Tensiones fijas seleccionables 50 V y 70 V CUT OFF Tensi n variable 100 Va O V Gl VARIABLE Polarizaci n
31. ocess at 50 mA knob at the right hand Plug the tip of the male connector of the H V cable into the female connector 4 at the panel the other end air hole into the V H V connector of the CRT unloaded previously The rejuvenating process will start through pushbutton RESTORER START 10 The TA 903 first will heat up the 02 2003 Analyser Rejuvenator 490B picture tube and then it will start rejuvenation The rejuvenating process is fully automatic and takes about 70 seconds The rejuvenating indicator RESTORER ON 11 is lighting for all the process time it goes out when rejuvenation is ended Rejuvenating current intensity can be followed at the instrument of the respondent cathode 2 R G or B When the rejuvenating process is started through pushbutton 10 RESTORER START it cannot be stopped but if the unit is unswitched through the POWER 5 switch After a rejuvenation process is fulfilled it is suitable to make a new measurement of emission in order to verify a likely variation As a rule the emission value is slightly higher however in some CRT it may be alike or a little lower Still it does not mean the rejuvenating process was resultless The rejuvenating process is likely to be repeated several times when applied in very exhausted tubes In colour tubes it is indispensable the emitting values of the 3 systems R G
32. ockets for several CRT Adapter cable CC 011 Anode cable CC 026 CRT Adapter List Included adapters Ao A7 A8 A9 A10 All Optional adapters A 0 Universal to be custom made by means of connection wires by the user Al A2 A3 A12 A14 A16 A17 A18 A20 A21 A22 A23 A24 A26 A27 Adapters set 006 Page 2 02 2003 C R T Analyser Rejuvenator 4905 2 INSTALLATION 2 1 Power supply This appliance is delivered ready to be fed with 220 V AC 50 60 Hz Before to connect the instrument be sure the supply voltage is the right one The equipment fits internally with mains voltages at 110 125 220 and 240 V AC 50 60 Hz If the instrument is to be connected to other mains voltages next steps should be followed WARNING Before to perform following steps unplug off the device from mains Remove the 6 fastening screws from the case and draw out the chassis Once the chassis is removed from the case change the power transformer plug over to the terminal of the chosen voltage 110 125 220 240V and replace the fuse if required Figure 1 Fuse type to be 5 x 20 mm and A for 110 125 5 A for 220 240 V 1 0 The instrument could get damaged if these instructions are neglected 02 2003 Page 3 English C R T Analyser Rejuvenator 4905 Page 4 02 2003 C R T Analyser Rejuvenator 4905 3 CONTROL DESCRIPTION Front Panel
33. performed of both the characteristic curve voltage and current of the three cathodes in function of the Gl voltage Page 14 02 2003 C R T Analyser Rejuvenator 4905 70 60 50 40 30 20 10 0 Va in V Figure 3 02 2003 1 2 in 0 8 0 6 0 4 0 2 0 0 Example of a diagram to draw characteristic curve Page 15 C R T Analyser Rejuvenator 4905 g TRACKING test Push key CUT OFF 21 Next to push the COLOUR TRACKING pushbutton 14 holding it for all the test time The meter pointers will deflect to about the middle of the scale Look at the meter that gives the highest measurement among the three Then turn controls 13 COLOUR TRACKING of the two other meters to the right hand one by one until to mate the measurement of the highest one On achieving it this means that difference of current between th CRT cathodes is contained within the admissible limits Otherwise it means that difference of current of the lowest cathode s is greater than the admissible on therefore th tube is to be rejuvenated Page 16 02 2003 C R T Analyser Rejuvenator 4905 02 2003 Page 17 C R T Analyser Rejuvenator 4905 5 MAINTENANCE 5 1 General Current maintenance by the user is bound to cleaning the instrument replacing fuses and incidentally a readjustment of the rejuvenator according with instr
34. produce la descarga de un condensador entre catodos y filamento del tubo TRC para eliminar las fugas 6 cortocircuitos Despu s pasar de nuevo a la posici n 18 SHORTS para verificar si a n permanec ncendida alguna lamparita De ser as repetir la misma operaci n dejando un espacio de 10 segundos para permitir la carga del condensador c Prueba qd misi n Apretar la tecla 22 EMISSION TEST Las agujas indicar n e1 valor de la emisi n de los c todos Los tubos de imagen de color en perfecto estado dar n valores de corriente comprendidos entre 0 8 a 1 6 mA aproximadamente y los de blanco y negro de 0 5 a 1 mA Los tubos utilizables y con buen resultado de regeneraci n se sit an entre 0 3 y 0 8 mA B N 0 3 a 0 5 mA Por el contrario generalmente no se obtienen resultados duraderos al regenerarse c todos situados por debajo de 0 3 mA B N 0 2 mA ya que est n demasiado agotados En emisi n el piloto 8 FOCO tiene que iluminarse indicando el correcto funcionamiento de dicho electrodo d Regeneraci n Para regenerar un TRC proceder como sigue 1 Pulsar la tecla 23 del c todo qu 5 qes regenerar roja si es el c todo rojo verde si es el c todo verde y azul si se trata del c todo azul Seleccionar la corrient d regeneraci n mediante el conmutador 12 En general es aconsejabl mpezar 4 proceso de regenerac
35. provided that a sufficient mass of barium oxide subsists in the cathode Lif xpectance test Th Lif xpectance test can be performed at any time provided that the CUT OFF voltage is set Push key EMISSION TEST 22 Meter pointers will state the cathode current value Note down these currents Now push the EMISSION LIFE TEST pushbutton 13 and hold it some seconds until pointers of the galvanometers get stopped Note down this second measurement of current Variation between thes currents will give an approximate idea of the life expectance of the picture tube For 10 division variations e g from 1 00 to 0 80 mA the life expectance will be less than 1 year For 5 division variations e g from 1 00 to 0 90 mA the life time may be about 1 year For variations between 2 and 3 divisions the life time may be about 1 to 2 years If measurement does not drop down the tube may be assumed in good order new or almost new The more difference there is between both measurement and the quickier the current drops down the less will be the life expectance of the picture tube In a new tube difference of current will be almost void Gl VARIABLE test Push key Gl VARIABLE 20 In this function the Gl voltage depends on the control Gl VARIABLE 27 position running from 100V to OV In this way a simultaneous plotting can be
36. s mesureurs 2 Touche CUT OFF Par cette touche le tub st port au point de coupure avec la commande 26 CUT OFF SET et 1 s lecteur 25 300 ou 600 V Le s lecteur 15 Gl BIAS polarise le tube avec 50 ou HOO Va Apr s avoir emmen le tube au point de coupure le bouton poussoir 14 COLOUR TRACKING permet quilibrer les courants des cathodes et galiser les courants d mission par les trois commandes B W R G et B 3 dans une marge limit e Touche EMISSION TEST Cette touche sert a mesurer le courant d mission des trois cathodes a la fois sur le point de coupure Par cons quent les r glages effectu s auparavant dans la fonction CUT OFF 21 ne peuvent pas tre modifi s Le bouton poussoir 13 LIFE TEST permet de juger la variation des courants des cathodes lorsque la tension du filament diminue Par la on peut se fair un id rapproch e du temps de vie du tube Touches RESTORE GUN Les touches B W R G ou B font le choix de la cathode que l on veut r g n rer le s lecteur 12 RESTORER CURRENT est utilis pour choisir deux intensit s de r g n ration 25 ou 50 mA Le bouton poussoir 10 RESTORER START fait d marrer le cycle de r g n ration signal par le voyant LED 11 RESTORER ON SHORTS
37. ts entre Gl et une cathode quelconque et entre les cathodes et le filament en appuyant et l chant le bouton poussoir 16 G1 K SHORT REMOVE Si le court circuit persiste appuyer plusieurs fois 7 circuit 8 foyer 9 10 R M 11 RESTORER ON e 12 R 13 LIFE TEST 14 couleur 15 Gl BIAS 16 17 18 Touche SHORTS Cette commande sert d celer les fuites ou courts circuits ntre les lectrodes du tube a travers les voyants a n on 24 F et R G ou B pour les fuites ou courts circuits entre le filament et les cathodes R G ou B Gl pour les fuites ou courts circuits entre Gl et les cathodes R G ou B Gl et G2 pour les fuites entre les lectrodes Gl et dans chaque cas deux voyants a n on s allument en m m temps Page 6 02 2003 Analyseur R g n rateur de T R C 490B 19 Touche 6 3 V 12 V Ces deux touches servent s lectionner la tension de filament du tube entre 6 3 V avec un courant maximum de 1A ou 12 V avec un courant d intensit maximum de 0 5 A 02 2003 Page 7 Francais 24 Analyseur R g n rateur de T R C 4905 Touche Gl VARIABLE Cette touche permet de r gler la tension de Gl entr 100 V et O V Ainsi la courbe caract ristique tension courant du tube peut tre trac e au moyen de la commande Gl VARIABLE entre 100 a 0 V Les indications de courant de faisceau sont lue
38. uciedad Esta viene causada por finas particulas de polvo que aun se encuentran dentro del tubo de vidrio despu s de su fabricaci n Estas part culas depositadas est ticamente son atra das por los electrodos las diversas rejillas y el c todo adheri ndose alli Cuantas mas particulas se depositen en el c todo tanta menos emisi n podr suministrar La imagen s vuelv floja e indefinida Estos tubos de imagen pueden repararse mediante una regeneraci n con buen resultado a condici n de que subsista suficiente masa de xido de bario en el c todo Prueba de Esperanza de Vida La prueba d speranza de vida puede realizarse en cualquier momento siempre qu ste ajustada la tensi n de corte CUT OFF Apretar la tecla 22 EMISSION TEST Las agujas de 105 medidores indicar n el valor de la corriente de los c todos Tomar nota de dichas corrientes Apretar el pulsador 13 EMISSION LIFE TEST y mantenerlo as unos segundos hasta que las agujas de los galvan metros se inmovilicen Tomar nota de esta segunda lectura de corriente La variaci n entre dichas corrientes nos dar una idea aproximada de la esperanza de vida del tubo de imagen Para variaciones de unas 10 divisiones ej de 1 00 a 0 80 mA la esperanza de vida ser menor de 1 a o Para variaciones de unas 5 divisiones ej de 1 00 a 0 90 mA pued sperarse
39. uctions as detailed in the following paragraph All other maintaining repairing and calibrating procedures should be performed by the PROMAX engineering department or licensed agents To pull out the chassis from the case open the item by removing the 6 panel screws Page 18 02 2003 C R T Analyser Rejuvenator 4905 02 2003 Page 19 Analyseur R g n rateur d R Ce 490B Francais Analyseur R g n rateur de T R C 490B Analyseur R g n rateur de T R C 490B ANALYSEUR R G N RATEUR DE T R C 490B 1 DIVERS 1 1 Description Le 490B est un instrument con u pour v rifier et r g n rer les tubes a rayons cathodiques TRC de t l vision et moniteurs blanc et noir ou couleur 11 est utile pour constater voire r parer les fuites ou courts circuits entre lectrodes mesurer le courant des cathodes RGB n un seul fois tracer les caract ristiques tension courant et r g n rer les cathodes s par ment 1 2 Sp cifications Filament Tensions par s lection 6 3 V 1 A max 12 V 0 5 A max Polarisation Gl Tensions fixes s lectionnables 50 V et 70 V CUT OFF Tension variable 100 V O V Gl VARIABLE Polarisation G2 Etendue de variation 30 V 600 V variable dans 2 chelles Essai d mission
40. una vida de aproximadamente 1 a o Para variaciones de 2 a 3 divisiones aproximadamente de 1 a 2 a os Si no desciende la lectura puede considerarse el tubo en buen estado nuevo casi nuevo Cuanta m s diferencia exista entre las dos lecturas y m s r pida sea la bajada de corriente menor ser la esperanza de vida del tubo de imagen 02 2003 P gina 13 nula f Prueba Gl Varia Apretar la tecl Analizador regenerador de T R C 490B En un tubo nuevo la diferencia de la corriente ser casi ble a 20 Gl VARIABLE En esta funci n la tensi n de Gl depende de la posici n del mando 27 Gl VARIABLE que va de 100V simultaneamente de los tres cat 70 460 Va in V g Prueba TRACKING a OV De esta manera se puede trazar la curva caracter stica tensi n y corriente odos en funci n de la tensi n de Gl 1 2 in 1 0 0 8 0 6 0 4 0 2 0 0 50 40 30 20 10 0 Figura 3 Apretar la tecla 21 CUT OFF Seguidamente apretar y mantener apretado el tiempo que dure la prueba el pulsador 14 COLOUR TRACKING Las agujas de los medidores se desviar n aproximadamente al centro de la escala Tomar nota visualment del tres Entonces TRACKING de lo medidor que de la lectura mas alta de los girar hacia la derecha los mandos 3 COLOUR s dos restantes uno a uno hasta conseguir igualar la lectura
41. yants correspondant aux lectrodes touch es s allumeront Par exemple F et G s allument les fuites ou courts circuits se trouvent entre le filament et la cathode verte Si un voyant 24 s allume appuyer sur la touche REMOVE Gl SHORT 17 Ensuite pousser le bouton poussoir Gl F SHORT 16 A ce moment la d charge d un condensateur se produira entre les cathodes et le filament du TRC pour supprimer les fuites ou courts circuits Apr s cela revenir sur la position SHORTS 18 pour v rifier si quelque voyant reste allum Dans ce cas r p ter la m me op ration apr s 10 secondes d attente pour permettre la charge du condensateur Essai d mission Pousser la touche EMISSION TEST 22 Les aiguilles montreront la valeur de 1 mission des cathodes Les tubes a image couleur en parfait tat donneront des valeurs de courant entre 0 8 et 1 6 mA peu pr s les tubes B N de 0 5 a 1 mA Les tubes utilisables avec un bon r sultat de r g n ration mesureront entre 0 3 et 0 8 mA B N de 0 3 8 0 5 mA En g n ral par contre on ne r ussit pas de r sultats durables dans la r g n ration de cathodes en dessous de 0 3 mA B N 0 2 mA parce que trop puis es En mode mission le voyant FOCO 8 doit s allumer pour Signaler le bon fonctionnement de cette lectrode d R g n ration M thode pour r g n rer un TRC