Home

30 AMP TO 20 AMP OUTLET ADAPTER

image

Contents

1. POWER IT L 30 AMP TO 20 AMP OUTLET ADAPTER PF923022 A DANGER To reduce the risk of injury the user must read and understand this insert sheet as well as the operator s manual for their portable generator before using this product Do not expose to rain or use in damp loca tions Failure to follow all warnings and precautions may result in death serious personal injury or property damage This outlet adapter converts a 120 240 volt 30 amp twist lock outlet to a 120 240 volt 20 amp twist lock outlet to be used on portable generators The load plugged into the 120 240 volt 20 amp outlet adapter should not exceed 20 amps Turn OFF the generator before plugging in the outlet adapter Al ways disconnect all loads from the generator before starting or stopping the generator To turn on the power to the 20 amp outlet adapter place the reset on off switch in the reset on position Operating voltage and frequency requirements of all electronic equipment should be checked prior to plugging them into this generator Damage may result if the equipment is not designed to operated within a 10 voltage variation and 3 hertz frequency variation from the generator name plate ratings AC CIRCUIT BREAKER A 120 240 Volt 30 Amp receptacle r ceptacle 120 240 volts 30 amp res recept culo de 120 240 voltios y 30 amperios B Reset on off switch interrupteur de r initialisation marche arr t interruptor de restable
2. Toujours d brancher toutes les charges de la g n ra trice avant de la d marrer ou l arr ter Allumer l alimentation lectrique de l adaptateur de prise de 20 amp res puis placer l interrupteur de r initialisation marche arr t la position de r initialisation marche reset on Les exigences de tension et de fr quence de fonctionnement de tout dispositif lectronique doivent tre v rifi es avant de les brancher la g n ratrice Des dommages aux disposi tifs peuvent survenir s ils ne sont pas con u pour tol rer une variation de tension de 10 et une variation fr quences de 3 hertz des caract ristiques nominales de la plaque signal tique DISJONCTEUR CA Ce disjoncteur est fourni afin de prot ger le cordon d alimentation contre les surcharges lectriques Le disjonc teur se d clenche d s que la tension d passe 20 amperes Le disjoncteur peut tre r iniatilis en appuyant sur le bouton de r initialisation reset ATTENTION Ne pas surcharger la capacit de pro duction de la g n ratrice Le d passement de la capacit de production de tension et d amp rage de la g n ratrice peut endommager la g n ratrice et ou les dispositifs lectriques qui y sont branch s PROPOSITION 65 DE LA CALIFORNIE A AVERTISSEMENT Ce produit les gaz d chappement qu il d gage et les autres substances rejet es dans l air a la suite de son utilisation peuvent contenir des produits chimiqu
3. 0 ft 125 ft 100 ft i pieds pies pieds pies pieds pies pieds pies 250 ft 150 ft 100 ft 50 ft 10 1200 2400 A pieds pies pieds pies pieds pies pieds pies 150 ft 100 ft 65 ft 15 1800 3600 P pieds pies pieds pies pieds pies 175 ft 125 ft 75 ft 20 2400 4800 pieds pies pieds pies pieds pies P 150 ft 100 ft 25 3000 6000 pieds pies pieds pies hl 125 ft 65 ft 90 ft 40 4800 9600 pieds pies TECHTRONIC INDUSTRIES NORTH AMERICA INC P O Box 35 Hwy 8 Pickens SC 29671 USA 1 866 340 3912 MH www powerfittools com 988000 647 1 24 12 REV 01 ADAPTATEUR DE PRISE 30 AMPERES A 20 AMPERES PF923022 A DANGER Pour r duire le risque de blessures Putilisateur doit lire et comprendre cet encart ainsi que le manuel d utilisation de la g n ratrice portative avant d utiliser ce produit Ne pas exposer l outil la pluie ni a l humidit Le non respect de tous les avertissements et de toutes les directives peut entrainer des dommages mat riels des blessures graves et m me la mort Cet adaptateur de prise pour g n ratrices portatives est utilis pour convertir la prise verrouillable de 120 240 volts 30 am peres en une prise verrouillable de 120 240 volts 20 amperes La charge branch e a un adaptateur de prise de 120 240 volts 20 amp res ne doit pas exc der 20 amperes teindre la g n ratrice avant de brancher l adaptateur de prise
4. cimiento encendido apagado C Outlet adapter adaptateur de prise adaptador de salida D Power cord cordon d alimentation cord n de corriente CAUTION Do not overload the generator s capacity Exceeding the generator s wattage amperage capacity may damage the generator and or electrical devices connected to it CALIFORNIA PROPOSITION 65 The circuit breaker is provided to protect the electrical cord against electrical overload Exceeding the 20 amp rating will trip the circuit breaker The circuit breaker may be reset by depressing the reset button A WARNING This product its exhaust and other sub stances that may become airborne from its use may contain chemicals including lead known to the State of California to cause cancer birth defects or other reproductive harm Wash hands after handling Load in Watts charge en watts carga en vatios At 120V At 240V Maximum Cord Length Current in Amperes i au z l P Longueur maximale du cordon Longitud maxima del cord n courant en amperes corriente en amperios 8 Wire cable cable 10 Wire cable cable 12 Wire cable cable 14 Wire cable cable 16 Wire cable cable A 120 V A 240 V 25 300 1000 ft 600 ft 375 ft 250 ft pieds pies pieds pies pieds pies pieds pies 5 1200 500 ft 300 ft 200 ft 125 ft pieds pies pieds pies pieds pies pieds pies 75 1800 350 ft 20
5. es notamment du plomb qui selon Etat de la Californie peuvent causer le cancer des anomalies cong nitales et d autres dommages au syst me reproducteur Bien se laver les mains apr s toute manipulation ADAPTADOR DE SALIDA DE 30 A 20 AMPERIOS PF923022 A PELIGRO Para reducir el riesgo de lesiones el usuario debe leer y comprender esta hoja agregada y el manual del operador correspondiente al generador portatil antes de usar este producto No exponga el producto a la lluvia ni lo utilice en lugares h medos No respetar to das las advertencias y precauciones puede ocasionar la muerte lesiones personales de gravedad o da os f sicos Este adaptador de salida convierte una salida con fijaci n por giro de 120 240 voltios y 30 amperios a una salida con fijaci n por giro de 120 240 voltios y 20 amperios para poder usarla con generadores port tiles La carga conectada al adaptador de salida de 120 240 voltios y 20 amperios no debe exceder los 20 amperios APAGUE el generador antes de enchufar el adaptador de salida Siempre desconecte todas las cargas del generador antes de arrancarlo o detenerlo Para encender el adaptador de salida de 20 amperios lleve el interruptor de restableci miento encendido apagado a la posici n de restablecimien to encendido Se deben verificar todos los requisitos de voltaje y frecuencia de operaci n de todos los equipos electr nicos antes de co nectarlos a este generador Se pueden oca
6. sionar da os si el equipo no est dise ado para funcionar con una variaci n de voltaje de 10 y con una variaci n de frecuencia de 3 hercios con respecto a los valores nominales que figuran en la placa de especificaciones del generador DISYUNTOR DE CA El disyuntor se utiliza para proteger el cable el ctrico contra sobrecargas el ctricas Si se excede el valor nominal de 20 amperios se accionar el disyuntor El disyuntor se puede restablecer presionando el bot n de restablecimiento PRECAUCI N No exceda la capacidad de carga del generador De excederse la capacidad de vataje amperaje del generador se podr a da ar el generador o los dispositivos el ctricos conectados CALIFORNIA PROPUESTA DE LEY N M 65 A ADVERTENCIA Este producto su escape y otras sustancias que puedan llegar a ser aerotransporta das por su uso pueden contener sustancias quimicas por ejemplo plomo consideradas por el estado de California como causantes de cancer defectos de nacimiento u otras alteraciones reproductivas L vese las manos despu s de utilizar el aparato