Home
Installation Instructions
Contents
1. Cutout Cutout observe all observe all MUST SUPPORT 68 Kg 150 LBS dimensione mid Et i gt 6 115 24 cm Min NOTE This oven is only approved to be installed under the specific models as labeled on this unit Installation Instructions Electrical Connections Turn off the circuit breaker or remove fuses ATTENTION INSTALLER to the oven branch circuit All electric wall ovens must be hard wired With the oven supported on a table or direct wired into an approved junction box A platform in front of the cabinet opening plug and receptacle is NOT permitted on these connect the flexible conduit to the electrical products Junction box as shown below Position the conduit in such a manner that it will fall on DO NOT shorten the flexible conduit the right back side of the oven in a natural The conduit strain relief clamp must be securely loop when the oven is installed You will attached to the junction box and the flexible need to purchase an appropriate strain conduit must be securely attached to the relief clamp to complete the connection of clamp If the flexible conduit will not fit within the conduit to the junction box the clamp do not install the oven until a clamp nn of the proper size is obtained NOTE TO ELECTRICIAN The 3 power leads Conduit supplied with this appliance are CSA recognized for connection to heavier gauge household wiring The insulation of these 3 leads is rated at temperatures
2. 28 5 8 po max _ 27 5 16 po max a Hauteur de 69 2 cm ntre les murs Pu l ouverture 27 1 4 po min 69 4 cm e 27 5 16 po max Pr voir 1 75 cm 11 16 po pour le chevauchement du four par dessus les c t s de l ouverture gt Pr voir une ouverture d au moins 72 4 cm 28 1 2 po de largeur Hauteur de l ouverture 69 2 cm 27 1 4 po min 69 4 cm Pr voir un d gagement d au moins 58 42 cm Pr voir 2 5 cm 1 po au moins pour le chevauchement du four par dessus le bord sup rieure Distance recommand e entre l ouverture et le plancher 82 6 cm et 3 2 cm 114 po le bord inf rieur de l ouverture 32 D l enceinte Al 76 2 cm 30 po 23 po pour l ouverture de la porte par rapport aux l ments adjacents coins tiroirs murs etc Installations c te c te Installez deux fours dans des enceintes distinctes Ligne du centre Ligne du centre 1 Mod les 87 6 cm 34 5 po I I et 50 8 cm 30 po Ouverture Respecter toutes les dimensions et exigences Ouverture Respecter toutes les dimensions et exigences gt lu 15 24 cm 6 po min Si l enceinte n est pas munie d un fond solide deux entretoises ou rails doivent tre pos s au niveau du bord inf rieur de l ouverture pour soutenir le poids du four Ces entretoises ou rails doivent supporter 68 kg 150 livres dans le cas d un four simple NOTE Si la trace de l ouverture
3. Built In Wall Oven n sta latio n 27 68 6 cm models JCK1000 JCK3000 JCK5000 Instructions do die JCT3000 JCT5000 PCT7050 If you have questions call 1 800 561 3344 or visit our website at www geappliances ca H e Proper installation is the responsibility Befo re You Beg In of the installer and product failure due Read these instructions carefully and completely to improper installation is NOT covered under e IMPORTANT save these warranty instructions for local inspector s use e NOTE This appliance must be properly grounded IM PORTANT observe all governing codes and ordinances e ATTENTION INSTALLER e Note to Installer Be sure to leave these All electric wall ovens must be hard wired instructions with the consumer direct wired into an approved junction box A e Note to Consumer Keep these plug and receptacle is NOT permitted on these instructions for future reference products Parts Included Materials Needed Taped to top of unit Ep Appearance will vary S 6 A P A CL LD Wire Nuts E OO Strain Relief Clamp Junction D for 1 2 conduit Box Screws for Oven Mounting Screws for Bottom Trim 8 18 x 750 flat head Phil Mounting 8 18 x 625 pan lips wood screws head Phillips sheet metal screws Metal Bottom Trim Assembly 1 8 3 mm Drill Bit and Phillips Electric or Hand Drill Screwdriver 31 10884 1 06 13 GE Installation Instructions IMPORTANT SAFETY INSTR
4. Directives d installation D Remise en place de la porte du four Ouvrez la porte du four jusqu son angle NOTE La porte du four est lourde Il se maximum peut que vous ayez besoin d aide pour la soulever assez haut pour la glisser dans Placez les verrous de la charni re en po ses charni res Ne soulevez pas la porte sition de verrouillage en poussant vers le par la poign e haut contre le panneau frontal du four Charniere en posi tion de verrouillage Pour soulever la porte du four saisissez la de chaque c t La porte est lourde de sorte que vous Encoche de la pourriez avoir besoin charni re bien d aide Ne soulevez pas sere ane le la porte par la poign e en Fermez la porte du four En maintenant la porte a la position d en levement qui correspond peu pr s la position ferm e placez l encoche du bras de charni re dans le bord inf rieur de la fente de la charni re L encoche doit tre bien ins r e dans le bas de la fente Bras de charni re Bord inf rieur de la fente Encoche du bras de charni re 11 Directives d installation M Liste de verification avant l essai S il y a lieu enlevez la pellicule protec Y V rifiez que les vis de montage sont bien trice et les tiquettes coll es sur le four en place et ne d passent pas la surface de la garniture lat rale voir la page 9 V rifiez que tout le c blage est bien fix et qu il n est pas coi
5. Slot Place hands on both sides of the door and close the oven door to the removal position which is most of the way closed Lift door up and out until the hinge arms clear the slots Hinge Clears Slot NOTE The oven door is very heavy Be sure you have a firm grip before lifting the oven door off the hinges Use caution once the door is removed Do not lay the door on its handle This could cause dents or scratches Y Place the oven on a table or platform even with the cutout opening Platform must support 68 Kg 150 lbs Remove the bottom trim from the top of the oven It will be installed at the end of the installation process The trim is wrapped separately and taped to the top of the unit Installation Instructions Al Cutout for 27 68 6 cm Single Built In Ovens only For JCK1000 JCK3000 JCK5000 models only Allow 2 5 cm 1 for overlap of oven over side edges of cutout 5 cm x 10 cm 2 x 4 or equivalent runners level with bottom of cutout 58 42 cm 23 gt Allow 2 5 cm Allow a minimum of 58 42 cm 23 for Cabinet Width 68 6 cm 27 Cutout Width 63 5 cm 25 Min 64 1cm 25 1 4 Max 1 minimum for overlap of Junction box recommended to be in right side adjacent cabinet port Cutout Height 70 2 cm 27 5 8 Min 71 4 cm 28 1 8 Max Recommended cutout location from floor 82 6 cm 32 1 2 Cab
6. 2 cm 27 1 4 Min 69 4 cm 27 5 16 Max Cutout Width Cutout Height NOTE If the cabinet does not have a front frame and the sides are less than 1 9 cm 3 4 thick shim both sides equally to establish the cutout width 5 cm x 10 cm 2 x 4 or equivalent runners level with bottom of cutout Suitable Bracing to Support Runners 54 9cm 4 21 5 8 Over Centerline of Cabinet These ovens are not approved for stackable installation Installation Instructions Al Cutout for 27 168 6 cm Single Built In Ovens only Under Counter For JCK1000 JCK3000 JCK5000 models only GE Electric cooktops may be installed over this oven See cooktop installation instructions for cutout size See label on top of oven for approved cooktop models Electrical connections for cooktop must be located in an adjacent accessible location to the right 63 5 cm 25 Top and or side fillers may be necessary if unit is positioned between existing cabinets Be sure they are attached securely since they will anchor the oven in the cabinet 25 Min 64 1cm 25 1 4 Max 70 2 cm 27 5 8 Min 71 4 cm 222 28 1 8 Max MUST SUPPORT 68 Kg 150 LBS a a E 11 Allow 2 5 cm 1 overlap top of oven 2 5 cm 1 overlap _ side edges of cutout and 2 5 cm 1 overlap bottom of cutout Must match toekick height 240V 208V Junc tion Box Location
7. Al Cutout for 30 76 2 cm Single Built In Ovens only For JCT3000 JCT5000 PCT7050 models only Cutout Width 72 4cm 28 1 2 Min 72 7 cm 28 5 8 Max Junction box recommended to be in right side adjacent cabinet RE Opening between inside walls must be at least 72 4 cm 28 1 2 wide Allow 2 5 cm 1 for overlap of oven top and 3 2 cm 1 bottom of cutout Cabinet width a 76 2 cm 30 Side by Side Installations Install two ovens in separate cutouts Center Line Center Line 1 34 5 87 6cm 30 models Cutout observe all dimensions and requirements Cutout observe all dimensions and requirements 69 4cm _ 127 5 16 Max Recommended cutout location from floor 82 6 cm 32 1 2 gt le 6 15 24 cm Min If the cabinet does not have a solid bottom two braces or runners must be installed level with the bottom of the cutout to support the weight of the oven For single ovens the runners and braces must support 68 kg 150 Ibs NOTE If marks blemishes or the cutout opening are visible above the installed oven it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered Cabinet Width Recommended Cutout Location from Floor Cutout Depth 76 2 cm 30 82 6 cm 32 1 2 59 7 cm 23 1 2 Min 72 4 cm 28 1 2 Min 72 7 cm 28 5 8 Max 69
8. Recommended e Fa E ountertop to be in right side Height adjacent cabinet 91 4 cm 36 61 cm 24 10 2 cm 4 Typical Toekick NOTE This oven is only approved to be installed under the specific models as labeled on this unit Installation Instructions Al Cutout for 30 76 2 cm Single Built In Ovens only Under Counter For JCT3000 JCT5000 PCT7050 models only GE electric cooktops may be installed over this oven See cooktop installation instructions for cutout size See label on top of oven for approved cooktop models 63 5 cm 25 Electrical connections for cooktop must be located in an adjacent accessible location to the right Top and or side fillers may be necessary if unit is positioned between existing gt cabinets Be sure they 72 4 cm are attached securely 28 1 2 Min since they will anchor 72 7 cm Allow 2 5 cm 1 the oven in the cabinet 28 5 8 Max overlap top of oven 240V 208V Junc 91 4 cm 36 69 2cm 1 8cm 11 16 tion Box Location Typical raa _ overlap side edges IR ded Countert 27 1 4 Min of cutout and 3 2 nl OA 69 4 cm to be in right side Height ars Max O adjacent cabinet PE SAFE 61 cm 24 10 2 cm 4 Typical Toekick Side by Side Installations Y oS Support Platform Install two ovens in separate cutouts Required _ 2 Must Center Line Center Line match 1 34 5 87 6cm toekick I 30 models height I L
9. con us pour raccorder du cuivre l aluminium et suivez Consultez le guide de d pannage de votre Manuel d utilisation et d entretien lt 8 SRS SS minutieusement la proc dure recommand e par le fabricant NOTE Le fil utilis l emplacement et l isolation des pissures etc doivent se conformer aux r gles de l art et au code de l lectricit en vigueur localement 12 Notes Notes
10. four et occasionner des blessures Ne permettez personne de grimper de s asseoir de se tenir sur la porte du four ou de s y suspendre e Assurez vous que les armoires de cuisine et les rev tements de mur autour du four peuvent supporter la temp rature pouvant atteindre 93 C 200 F produite par le four AVERTISSEMENT vous devez couper l alimentation lectrique du four avant de le brancher Le d faut de se conformer cette proc dure peut entra ner des blessures s v res et m me la mort Alimentation Cet appareil doit tre aliment avec un courant de tension et de fr quence appropri es et connect un circuit individuel ad quatement mis la terre et prot g par un disjoncteur ou un fusible Veuillez consulter la plaque signal tique situ e sur le cadre du four afin de d terminer la puissance nominale du produit Servez vous du tableau ci dessous pour d terminer la protection minimale recommand e du circuit d di Puissance Puissance Calibre nominale en kW nominale recommand pour 240V en kW 208 V le circuit d di 4 8 kW S41 kW 49kwa72kw 43kWa62kW 73kW 96kW 63kW 8 3kW 97kWa 120kW 8 4kW 104kW Alimentation suite La plaque signal tique est situ e sur la garniture lat rale du four Emplacement de la plaque signal tique Nous vous recommandons de faire r aliser le c blage lectrique et le branchement de votre four par un lectricien qualifi A
11. le haut du four Elle sera pos e la fin du montage La garniture est emball e s par ment et fix e dans le haut du four par du ruban adh sif Directives d installationz a Ouverture pour fours encastr s simples 27 po 68 6 cm seulement Pour les mod les JCK1000 JCK3000 JCK5000 seulement Largeur de l enceinte 68 6 cm 27 po Largeur de l enceinte c t droit d en Distance recommand e 686cm ceinte adjacente entre l ouverture et 27 po recommand pour l installation de la le plancher 82 6 cm 32 1 2 po boite de jonction Ines Profondeur de 59 7cm louverture l ouverture 23 1 2 po min 25 po min e Largeur de 63 5 cm Pr voir 2 5 1 po 64 1 cm our le chevaucheneit 25 1 4 po max l ouverture 25 po m n du four par dessus les c t s de l ouverture e 64 1 cm 25 1 4 po max 5 cm x 10 cm 2 po x 4 po FIOUEEUR er de l ouverture ou rails quivalents au Hauteur de 70 2 cm niveau du bord inf rieure 70 2 cm 27 5 8 po min a 71 4 cm 28 1 8 po max l ouverture 27 5 8 po min 71 4 cm 28 1 8 po max Distance recommand e gt Pr voir 2 5 cm 1 pol entre l ouverture et le NOTE Si l enceinte n est pas dot e PAS au moins pour le che Pr voir un d gagement P d au moins 58 42 cm Ro du four d un panneau frontal et si l paisseur 23 pol pour ouverture aid m des c tes fait moins de 1 9 cm 3 4 aux l ments adjacents de louvertu
12. temp rature nominale de l isolant autour du fil U Ce four est dot d un conduit flexible de 123 cm 48 po comportant raccordement inad quat d un 3 conducteurs isol s en cuivre c blage r sidentiel en aluminium 1 conducteur de mise la terre des fils de sortie en cuivre peut entra ner d nud en cuivre un risque lectrique ou d incendie Utilisez Raccordez les conducteurs au c blage AVERTISSEMENT ite uniquement des connecteurs congus de la maison tel qu illustr dans le sch ma pour raccorder du cuivre l aluminium et de c blage respectez minutieusement la proc dure Br CONDUITEN recommandee par le fabricant PROVENANCE NE T une arado DU FOUR neutre prouv par la CSA LS VERS LE PANNEAU DE DISJONCTEURS noir ROUGE Fil de cuivre NMD90 12 10 AWG Fusible 20 amp disjoncteurs FIL DE MISE LA TERRE Bo te de jonction et couvercle A approuv s par la CSA Directives d installation Fixation du four dans l ouverture Mise en place du four dans l ouverture Agrippez le four par l int rieur de son orifice pour le soulever fermement jusque dans l ouverture de l enceinte Poussez avec pr caution sur le devant du ch ssis du four Ne poussez pas sur les bords ext rieurs ESOO S OO OSOS N Ein N RN 3 CZ gt gt O Percage des trous de guidage et montage du four NOTE BAvant de percer les trous de guidage
13. UCTIONS For Your Safety e Be sure your oven is installed properly by a qualified installer or service technician e Be sure the oven is securely installed in a cabinet that is firmly attached to the house structure Weight on the oven door could cause the oven to tip and result in injury Never allow anyone to climb sit stand or hang on the oven door e Make sure the cabinets and wall coverings around the oven can withstand the temperatures up to 93 C 200 F generated by the oven WARNING The electrical power to the oven supply line must be shut off while line connections are being made Failure to do so could result in serious injury or death Electrical Requirements This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or fuse See the rating plate located on the oven frame to determine the rating of the product Use the chart below to determine the minimum recommended dedicated circuit protection Recommended KW Rating KW Rating Circuit Size 240V 208V ECON 20Amp Electrical Requirements cont Rating Plate is located on oven side trim Rating Plate Location We recommend you have the electrical wiring and hookup of your oven connected by a qualified electrician After installation have the electrician show you where your main oven disconnect is located Check with your local
14. assurez vous de pousser le four jusqu l endroit o il doit aller et de le centrer ad quatement a Percez travers les trous de montage haut et bas de la garniture lat rale pour recevoir les vis 8 fournies Les vis doivent tre Emplacement de montage L emplace m ent des trou des trous A une distance d au moins 6 mm 1 4 po du devant de l ouverture peut varier gt N IN AVERTISSEMENT Des vis de montage doivent tre utilis es Le d faut de se conformer cette directive peut occasionner la chute de four et par voie de cons quence des blessures s v res b Fixez le four l enceinte l aide des vis fournies NOTE Si l enceinte est en panneaux de parti cules vous devez utiliser des vis z 8 x 19 mm 3 4 po con ues pour ce mat riau On peut s en procurer dans n importe quelle quincaillerie Directives d installation Installation de la garniture inf rieure e Lorsque le four est install ins rez la garniture inf rieure dans ses trous de montage l avant de l entretoise en utilisant les deux vis pour garniture fournies Le rebord de la garniture inf rieure doit tre plac e sous la collerette ou au bas du conduit d air IMPORTANT La garniture risque d tre endommag e si elle n est pas enlev e en premier lorsque l appareil est retir de l enceinte pour une r paration ou une autre raison 10
15. c du ruban sur le dessus de l appareil L aspect des pi ces peut varier amp Vis pour montage du four Vis pour montage de vis bois t te frais e garniture inf rieure vis cruciforme 8 18 x 0 750 m canique 8 18 x 0 625 t te cruciforme Montage de garniture inf rieure m tallique 31 10884 1 06 13 GE e Il est de la responsabilit de l installateur de proc der une installation appropri e Un dysfonctionnement du produit qui r sulterait d une installation incorrecte ne serait pas couvert par la garantie e NOTE Cet appareil doit tre mis la terre ad quatement AVIS IMPORTANT L INSTALLATEUR Tous les fours muraux encastr s doivent tre raccord s raccordement direct dans un bo tier de jonction homologu Une fiche et une prise de courant ne sont PAS autoris es pour brancher ces produits Mat riel requis Sp Serre fils Bague anti traction Bo te de pour conduit de 1 2 po jonction ei Perceuse lectrique ou Tournevis pointe manuelle et m che de cruciforme 3 mm 1 8 po Directives d installation CONSIGNES DE SECURITE IMPORTANTES Pour votre securite e Assurez vous que votre four est bien mont par un installateur qualifi ou un technicien de service e Assurez vous que votre four est mont en toute s curit dans une enceinte qui est bien fix e la structure de votre maison Toute pression appliqu e sur la porte du four peut faire tomber le
16. d on each side The door is heavy so you may need help Do not lift the door Notch of Hinge by the handle Securely Fitted into Bottom of Hinge Slot With the door at the same angle as the removal position which is most of the way closed seat the notch of the hinge arm into the bottom edge of the hinge slot The notch of the hinge arm must be fully seated into the bottom of the slot Hinge Arm Bottom Edge of Slot Hinge Notch 11 Installation Instructions VW Pre Test Checklist Remove all protective film if present Y Check to be sure the mounting screws and any stickers are installed and flush with the side trim see page 9 Check to be sure that all wiring is secure and not pinched or in contact with Y Ensure that air duct at bottom of unit is moving parts free of obstructions Check that the bottom trim is installed properly see page 10 Operation Checklist Remove all items from the inside Y NOTE TO ELECTRICIAN The power leads of the oven supplied with this appliance are CSA recognized for connections to larger Check that conduit is securely gauge household wiring The insulation connected to the junction box of these leads is rated at temperatures much higher than the temperature Turn on the power to the oven Refer to rating of household wiring The current your Owner s Manual Verify that the carrying capacity of a conductor is bake and broil units and all cooking governed by th
17. des marques ou des imperfections sont visibles au dessus du four il peut tre n cessaire d ajouter des cales de bois sous les rails et la garniture frontale jusqu a ce que les d fauts ou la trace de l ouverture soient cach s NOTE Si l enceinte n est pas dot e d un panneau frontal et si l paisseur des c t s fait moins de 1 9 cm 3 4 po placez des cales d gale paisseur de chaque c t pour d terminer la largeur de l ouverture 5 cm x 10 cm 2 po x 4 po ou rails quivalents au niveau du bord inf rieure Entretoisement ad quat afin de supporter les rails Distance ____ de 54 9 cm 21 5 8 po centr e sur la ligne de centre de l enceinte Ces fours ne sont pas approuv s pour un montage superpos Directives d installation Al Ouverture pour four encastr simple in stall au dessous d un comptoir 27 po 68 6 cm Pour les modeles JCK1000 JCK3000 JCK5000 seulement Les tables de cuisson GE Electric peuvent tre install amp es sur ce four Voir les instructions d installation de la table de cuisson pour connaitre la taille de l ouverture Voir l tiquette sur le dessus du four pour connaitre les modeles de table de cuisson approuves Les connexions lectriques pour la table de cuisson doivent tre 63 5 cm 25 po situ es droite dans un endroit adjacent accessible Des garnitures sup rieures et ou lat rales peuvent tre n cessaires si le four est install entre deux a
18. e wire gauge and also functions operate properly the temperature rating of the insulation around the wire NOTE ALUMINUM WIRING A WARNING improper CONNECTION OF ALUMINUM HOUSE WIRING TO THE COPPER LEADS CAN RESULT IN AN ELECTRICAL HAZARD OR FIRE Splice copper wires to aluminum wiring using special connectors designed and CSA approved for joining copper to aluminum and follow the manufacturer s Check that the circuit breaker is not tripped nor the house fuse blown See your Owner s Manual for troubleshooting list LR SSS QS SS recommended connector procedure closely NOTE Wire used location and enclosure of splices etc must conform to good wiring practice and local codes 12 Notes Notes Directives d installation Four mural encastre de modeles de 27 po 68 6 cm JCK1000 JCK3000 JCK5000 modeles de 30 po 76 2 cm JCT3000 JCT5000 PCT7050 Si vous avez des questions composez le 1 800 561 3344 ou visitez notre site web www electromenagersge ca Avant de commencer Lisez compl tement et attentivement les directives suivantes IMPORTANT conservez ces directives pour votre inspecteur local IM PORTANT Respectez tous les codes et les d crets en vigueur e Note a l intention de l installateur Assurez vous de laisser ces directives chez le consommateur e Note au consommateur Conservez ces directives pour consultation ult rieure Pieces incluses Fix ave
19. inet Width Recommended Cutout Location from Floor Cutout Depth Cutout Width Cutout Height 68 6 cm 27 82 6 cm 32 1 2 59 7cm 23 1 2 Min 63 5 cm 25 Min 64 1 cm 25 1 4 Max 70 2 cm 27 5 8 Min 71 4 cm 28 1 8 Max clearance to adjacent corners drawers walls etc when door is open NOTE If the cabinet does not have a front frame and the sides are less than 1 9 cm 3 4 thick shim both sides equally to establish the cutout width oven top and bottom of cutout dl 5 cm x 10 cm 2 x 4 or equivalent runners level Ifthe cabinet does not have a solid bottom two ii wer cutout braces or runners must be installed level with the bottom of the cutout to support the weight of the oven For single ovens the runners and braces must support 68 kg 150 Ibs NOTE If marks blemishes or the cutout opening are visible above the installed oven it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered lt 45 7 cm 18 gt lt 68 6 cm 27 gt These ovens are not approved for stackable installation Allow 1 75 cm 11 16 for overlap of oven over side edges of cutout 58 42 cm 23 Allow a minimum of 58 42 cm 23 for clearance to adjacent corners drawers walls etc when door is open Installation Instructions
20. is centered a Drill through the mounting holes top and bottom of the side trim for the 8 screws provided IN mountin The screws must be Me ie EX a minimum of 6 mm tions Hole 1 4 from the front N of the cutout WL ee oe SH SSS AN WARNING Mounting screws must be used Failure to do so could result in the oven falling out of the cabinet causing serious injury b Secure the oven to cabinet with screws pro vided NOTE If the cabinet is particle board you must use 8 x 19 mm 3 4 particle board screws These may be purchased at any hardware store Installation Instructions Bottom Trim Installation e With oven installed attach the bottom trim through its mounting holes in front vertical brace using two trim screws provided Bottom trim lip must be placed under flange or bottom of air duct IMPORTANT If this unit is ever removed from the cabinet or the oven is ever pulled out for service the bottom trim must be removed first or damage to the trim will occur 10 Installation Instructions D Replacing the Oven Door Open the oven door as far as it NOTE The oven door is heavy You may ua open need help lifting the door high enough to slide it into the hinge slots Do not lift the Push the hinge locks up against the front door by the handle frame of the oven cavity to the locked position Lift the oven door by ched Pot placing one han
21. l enceinte raccord s raccordement direct dans une connectez le conduit flexible a la boite de bo te de jonction approuv e Une fiche et une jonction tel qu illustr ci dessous Positionnez Ages le conduit de mani re ce qu il tombe prise de courant ne sont PAS autoris es pour naturellement en boucle l arri re du c t brancher ce produit droit du four lorsque ce dernier est install NE PAS raccourcir le conduit flexible La Vous devez vous procurer une bague anti traction appropri e pour terminer la bague anti traction du conduit doit tre fix e connexion du conduit la bo te de jonction fermement le bo te de jonction et le conduit Emplacement de la flexible doit tre fix fermement la bague Si dr did le conduit flexible n est pas ajust la bague procurez vous une bague dont la taille est appropri e avant d installer le four AVIS L LECTRICIEN TLes 3 fils lectriques de sortie fournis avec cet appareil sont approuv s par la CSA pour un branchement du c blage r sidentiel de calibre Gauge sup rieur Les temp ratures nominales de l isolant de ces 3 files sont beaucoup plus lev es que celles du c blage r sidentiel La capacit de transport Une bague anti traction du courant support e par un conducteur Placer le four sur un non incluse doit tre util support pour faciliter is e la bo te de jonction est d termin e par le calibre du fil et la la connexion du conduit
22. much higher than the temperature rating of household wiring The current carrying capacity of the conductor is governed by the wire gauge and the temperature rating of the insulation around the wire Strain Relief Clamp Place oven on a support to assist in connecting conduit WARNING Improper a connection of aluminum house wiring to copper leads can result This oven is supplied with a 123 cm 48 in an electrical hazard or fire Use only long flexible conduit consisting of connectors designed for joining copper to 3 insulated conductors copper aluminum and follow the manufacturer s 1 bare ground conductor copper recommended procedure closely not included must be used at Junction Box Attach conductors to residence wiring as shown by wiring diagram CONDUIT N FROM WHITE NEUTRAL CSA APPROVED CONNECTOR TO BREAKER PANEL 12 10 AWG COPPER NMD90 WIRE FUSE 20 GROUND AMP CIRCUIT BREAKERS CSA APPROVED 7 JUNCTION BOX AND COVER Installation Instructions Securing the Oven in the Opening ca Sliding the Oven Into the Opening Lift oven into cabinet cutout using the oven opening as a grip Carefully push against oven front frame Do not push against out side edges ESOO OS SS E OSOS ANY N Drilling the Pilot Holes and Mounting the Oven NOTE Before drilling the pilot holes make sure the oven is pushed as far back into the opening as it will go and
23. nc ou en contact Y Assurez vous que le bas du conduit avec des pieces en mouvement d air de l appareil est libre de toutes obstructions V rifiez que la garniture inf rieure est bien mont e voir la page 10 Liste de v rification pour l essai Enlevez tous les articles l int rieur NOTE L USAGE DE L LECTRICIEN Les du four fils lectriques de sortie fournis avec cet appareil sont approuv s CSA pour un V rifiez que le conduit est bien connect branchement du c blage r sidentiel la bo te de jonction de calibre sup rieur Les temp ratures nominales de l isolant de ces fils sont Mettez le four en marche consultez votre beaucoup plus lev es que celles du Manuel d utilisation et d entretien V rifiez c blage r sidentiel La capacit de que toutes les op rations de cuisson transport du courant support e par un fonctionnent ad quatement y compris conducteur est d termin e par le calibre les modes Cuisson Bake et Gril Broil du fil et la temp rature nominale de i E l isolant autour du fil V rifiez que le disjoncteur n est pas d clench ou le fusible de la maison grille NOTE CABLAGE D ALUMINIUM a AVERTISSEMENT LE RACCORDEMENT INAPPROPRIE D UN CABLAGE RESIDENTIEL EN ALUMINIUM A DES FILS DE SORTIE EN CUIVRE PEUT ENTRAINER UN RISQUE ELECTRIQUE OU D INCENDIE Raccordez les fils de cuivre au c blage d aluminium l aide de connecteurs sp ciaux approuv s CSA
24. pres le montage demandez l lectricien de vous montrer l emplacement de l interrupteur d isolement de votre four V rifiez aupr s de votre compagnie d lectricit le code de l lectricit r gissant les installations lectriques dans votre r gion Si vous ne branchez pas votre four conform ment au code en vigueur vous vous exposez une situation dangereuse En l absence d un code de l lectricit local votre four doit tre muni d un branchement et de fusibles qui r pondent la norme CAN CSA C22 2 No O M91 ou la derni re dition Vous devez utiliser un circuit lectrique pr sentant les caract ristiques suivantes courant monophas c a trifilaire 208Y 120 volts ou 240 120 volts 60 hertz Si vous vous branchez du c blage en aluminium vous devez utiliser des connecteurs correctement mont s et approuv s pour ce type de c blage Directives d installation NV Liste de v rification avant montage Y Y Enlevez tous les mat riaux d emballage V rifiez l arri re des charni res Enlevez les tiquettes sur la face ext rieure de la porte la matiere plastique sur les garnitures et le panneau ainsi que le ruban coll autour du four Enlevez aussi les vis d expedition qui fixent le four sur sa base Ne retirez pas les plaques signal tiques l int rieur Grilles du four Pochette documentation Ouvrez la porte du four et enlevez la documentation ainsi que les grille
25. re po placez des cales d gale pais coins tiroirs murs etc lt d seur de chaque c t pour d terminer la largeur de l ouverture plancher 82 6 cm 32 1 2 po Si l enceinte n est pas munie d un fond solide une 2 po x 4 po ou deux entretoises ou rails doivent tre pos s au a niveau du bord inf rieur de l ouverture pour soutenir le poids du four Ces entretoises ou rails doivent supporter 68 kg 150 livres dans le cas d un four simple NOTE Si la trace de l ouverture des marques ou des imperfections sont visibles au dessus du four il peut tre n cessaire d ajouter des cales de bois sous les rails et la garniture frontale jusqu ce 45 7 cm 18 pol que les d fauts ou la trace de l ouverture lt 68 6 cm 27 po gt soient cach s Ces fours ne sont pas approuves pour un montage superpose Directives d installation Al Ouverture pour fours encastres simples 30 po 76 2 cm seulement Pour les modeles JCT3000 JCT5000 PCT7050 seulement Largeur de l enceinte Distance recommand e entre l ouverture et le plancher Profondeur de l ouverture Largeur de l ouverture 76 2 cm 30 po Largeur de l ouverture 72 4 cm 28 1 2 po min 72 7 cm 28 5 8 po max C t droit d en ceinte adjacente recommand pour l installation de la bo te de jonction 82 6 cm 32 1 2 po 59 7 cm 23 1 2 po min 72 4 cm 28 1 2 po min 72 7 cm
26. rmoires existantes As surez vous qu elles soient solidement fix es au four car elles vont servir fixer le four l armoire Laissez un chevauchement de 2 5 cm 1 po au _ dessus du four de 2 5 cm 1 po sur les c tes de l ouverture et de 2 5 cm 1 po au dessous du four 240V 208V Em 91 4 cm 36 po placement de la Hauteur standard boite de jonction du comptoir de boite de jonction cuisine peut tre dans l ar moire adjacente 27 5 8 po min 71 4 cm g 28 1 8 po max _ A A ARA vr 1 Vp Cae Ree Te FETE E 61 cm 24 po 10 2 cm 4 po Hauteur standard du coup de pied La hauteur doit correspondre celle du coup de pied Directives d installation Al Ouverture pour four encastr simple in stalle au dessous d un comptoir 30 po 76 2 cm Pour les modeles JCT3000 JCT5000 PCT7050 seulement Les tables de cuisson GE Electric peuvent tre install amp es sur ce four Voir les instructions d installation de la table de cuisson pour connaitre la taille de l ouverture Voir l tiquette sur le dessus du four pour connaitre les modeles de table de cuisson approuves Les connexions lectriques pour 63 5 cm 25 po la table de cuisson doivent tre situ es droite dans un endroit adjacent accessible Des garnitures sup rieures et ou lat rales peuvent tre n cessaires si le four est install entre deux armoires existantes As 28 1 2 po min surez vous q
27. s Retirez les directives d installation de la pochette documentation et lisez les attentivement avant de commencer Assurez vous de ranger la documentation dans un endroit s r pour consultation ult rieure Il est possible d enlever la porte du four pour faciliter l installation bien que cela ne soit pas obligatoire Pour enlever la porte Ouvrez la porte jusqu son angle maximum Charni re en Amenez les deux position de charni res en position e ee de d verrouillage en les abaissant vers le ch ssis de la porte S il le faut utilisez un Bras de la tournevis lame plate charni re Placez vos mains de chaque c t de la porte et refermez la porte du four jusqu la position d enl vement qui correspond peu pr s la position ferm e Soulevez la porte en tirant vers l ext rieur jusqu ce que les bras des charni res sortent des fentes Charni re sortie de la fente NOTE La porte du four est tr s lourde Assurez vous de bien la tenir avant de la soulever pour la s parer des charni res Soyez vigilant une fois la porte enlev e Ne laissez jamais la porte reposer sur sa poign e Cela pourrait la rayer ou la bosseler Placez le four sur une table ou une plate forme de niveau avec l ouverture qui a t pratiqu e pour recevoir le four la plate forme doit pouvoir supporter 68 kg 150 livres dans le cas d un four simple Enlevez la garniture inf rieure fix e temporairement dans
28. u elles soient 72 7 cm Laissez n solidement fix es au four 1 car elles vont servir fixer ae 240V 208V Em 91 4 cm 36 po le four al i H P placement de la Hauteur standard Toura armel 69 2 cm ge au dessus du four bo te de jonction 27 1 4 po min 77 7 de 1 8 cm 11 16 po boite de jonction Era a 69 4 cm f sur les c t s de nee f cuisine 3 A peut tre dans l ar l ouverture et de moire adjacente 61 cm 24 po 10 2 cm 4 po i _ Hauteur standard SS du coup de pied 1 9 cm 3 4 po Plateforme de support 74 Installations c te c te Installez deux fours dans des enceintes distinctes J eter 27 La hauteur Ligne du centre Ligne du centre doit correspondre 1 Mod les 87 6 cm 34 5 poll celle du 1 _ et 50 8 cm 30 po coup de pied Teen Lh Ouverture Ouverture Respecter toutes Respecter toutes DOIT POUVOIR SUPPORTER 68 KG 150 LB les dimensions les dimensions et exigences et exigences gt lu 15 24 cm 6 po min NOTE Ce four est approuv uniquement pour une installation sous les modeles particuliers mentionn s sur l tiquette appos e sur cet appareil Directives d installation Raccordement lectrique AVIS IMPORTANT Mettez le disjoncteur hors circuit ou enlevez les fusibles du circuit terminal du four U L INSTALLATEUR Le four reposant sur une table ou une plate Tous les fours muraux encastr s doivent tre forme en face de l ouverture de
29. utilities for electrical codes which apply in your area Failure to wire your oven according to governing codes could result ina hazardous condition If there are no local codes your oven must be wired and fused to meet the requirements of CAN CSA C22 2 No O M91 or latest edition You must use a three wire single phase A C 208Y 120 Volt or 240 120 Volt 60 hertz electrical system If you connect to aluminum wiring properly installed connectors approved for use with aluminum wiring must be used Installation Instructions Remove packaging materials Check behind hinges Remove labels on the outside of the door plastic on trims and panel alltape around the oven and any shipping screws securing the oven to the base pad Do not remove internal rating plate labels Oven Racks Literature Pack Open oven door and remove literature pack and oven racks Remove Installation Instructions from literature pack and read them carefully before you begin Be sure to place all literature Owner s Manual Installations etc in a safe place for future reference Y Y Y Y VW Pre Installation Checklist Door removal is not a requirement for installation of the product but is an added convenience To remove the door Open the oven door as far as it will go Hinge Unlocked Position Push both hinge locks down toward the door frame to the unlocked position This may require a flat blade screwdriver Hinge