Home
Instruments de mesure de la vitesse de l` air Airflow modele
Contents
1. INSTRUMENTS DE MESURE DE LA VITESSE DE L AIR AIRFLOW MODELE TA465 E MANUEL D UTILISATION ETDE FONCTIONNEMENT P N 6005363 REV D OCTOBER 2014 INSTRUMENTS START SEEING THE BENEFITS QF REGISTERING TODAY Thank you for your TSI instrument purchase Occasionally TSI releases information on software updates product enhancements and new products By registering your instrument TSI will be able to send this important information to you http register tsi com As part of the registration process you will be asked for your comments on TSI products and services TSl s customer feedback program gives customers like you a way to tell us how we are doing UNDERSTANDING ACCELERATED TSI Incorporated Visit our website www tsi com for more information USA Tel 1 800 874 2811 India Tel 91 80 67877200 UK Tel 44 149 4 459200 China Tel 86 10 8219 7688 France Tel 33 4 91 11 87 64 Singapore Tel 65 6595 6388 Germany Tel 49241523030 2013 TSI Incorporated Printed in U S A Copyright TSI Incorporated 2011 2014 Tous droits r serv s Adresse TSI Incorporated 500 Cardigan Road Shoreview MN 55126 USA T l copie 651 490 3824 LIMITATION DE GARANTIE ET DE RESPONSABILIT entr e en vigueur en juin 2011 Pour chaque pays les modalit s et conditions en dehors des Etats Unis s il vous pla t visitez www tsi com Le vendeur garantit que si les produits vendus dans le cadre des pr
2. tre align avec le connecteur la base de l instrument de mesure s rie TA465 Gr ce cette position la sonde est assur e d tre correctement connect e et le reste en cours d utilisation Apr s avoir effectu la connexion et la mise en marche reportez vous la CONFIGURATION DE L AFFICHAGE pour l affichage des mesures d sir es 4 Chapitre 2 Connecteur mini DIN en forme de D Utilisation des sondes t lescopiques du thermo an mom tre La sonde t lescopique inclut les capteurs de vitesse de temp rature et d humidit Lors de l utilisation de la sonde veillez ce que la fen tre du capteur soit enti rement expos e et ce que l entaille d orientation soit plac e vers l amont REMARQUE Dans le cadre des mesures de temp rature et d humidit veillez ce qu une partie quivalente au moins 7 5 cm de la sonde se trouve dans le flux de mani re permettre aux capteurs de temp rature et d humidit d tre dans le courant d air D ploiement de la sonde Pour d ployer la sonde maintenez la poign e d une main tout en tirant sur l extr mit de la sonde de l autre main Ne maintenez pas le c ble lorsque vous d ployez la sonde faute de quoi vous ne pourrez pas d plier la sonde R tractation de la sonde Pour r tracter la sonde maintenez la poign e d une main tout en appuyant doucement sur le c ble de la sonde jusqu ce que la plus petite section de l antenne soit
3. F Sample 2 14 2 rh Sample 3 316 ft min Sample 3 73 8 F Sample 3 13 8 rh Sample 4 399 ft min Sample 4 73 8 F Sample 4 13 8 rh Sample 5 188 ft min Sample 5 73 6 F Sample 5 13 5 rh Sample 6 306 ft min Sample 6 73 6 F Sample 6 13 6 rh Sample 7 313 ft min Sample 7 73 5 F Sample 7 13 6 rh Sample 8 294 ft min Sample 8 73 4 F Sample 8 13 5 rh Sample 9 309 ft min Sample 9 73 4 F Sample 9 13 5 rh V V V lt PRINT gt lt PRINT gt lt PRINT gt Le TA465 peut envoyer ces donn es vers l imprimante sans fil mod le 8934 en option ou un PC compatible avec les communications Bluetooth Pour pouvoir utiliser la commande IMPRESSION il convient d tablir les communications Bluetooth entre le TA465 et l imprimante sans fil mod le 8934 ou un PC quip des communications Bluetooth Imprimer le test Appuyez sur ENTREE pour imprimer toutes les statistiques et les chantillons du test ID s lectionn s VIEW DATA WE Choose Test Test 001 View Stats View Samples Print Test Utilisation 27 Le TA465 peut envoyer ces donn es vers l imprimante sans fil mod le 8934 en option ou un PC compatible avec les communications Bluetooth Pour pouvoir utiliser la commande IMPRESSION il convient d tablir les communications Bluetooth entre le TA465 et l imprimante sans fil mod le 8934 ou un PC quip des communications Bluetooth Pour plus d informati
4. Les param tres indiqu s dans l cran Configuration de l affichage d pendent du type de sonde actuellement connect e En r glant sur PRIMAIRE la mesure sera en grande police sur l cran e En r glant sur ON la mesure sera affich e en tant que param tre secondaire il est possible d en afficher quatre la fois e En r glant sur OFF la mesure ne sera pas affich e MENU MTF Zero Press Display Setup DBPUY SETUP MT Settings Velocity ON Flow Setup Flow OFF VOC Setup Pitot Velocity OFF Actual Std Setup Pressure ON Data Logging Temperature ON Zero CO Baro Press OFF Applications Calibration Bluetooth Functions ON PRIMARY OFF REMARQUE La vitesse Pitot et la vitesse de la sonde AF ne peuvent pas tre toutes les deux sur ON en m me temps et vous ne pouvez pas non plus en r gler une sur PRIMAIRE et l autre sur ON Une seule peut tre sur ON un quelconque moment donn 14 Chapitre 3 PARAMETRES SETTINGS Le menu des Param tres vous permet de d finir les param tres g n raux Ils incluent la langue le signal sonore la s lection des unit s la constante de temps le contraste l heure la date le format de l heure le format de la date le format des nombres le r tro clairage et la d sactivation automatique Utilisez les touches A ou Y pour s lectionner une option et utilisez les touches d envoi lt ou gt pour modifier les param tres de chaque optio
5. vous devez changer le commutateur DIP Reportez vous au paragraphe suivant Param tres du commutateur DIP Les piles au carbone zinc ne sont pas recommand es en raison du risque de fuite de l acide des piles Param tres du commutateur DIP Pour acc der au commutateur DIP retirez les piles du compartiment des piles l int rieur du compartiment des piles se trouve une fen tre avec un commutateur DIP voir l illustration ci dessous Le tableau ci dessous d taille les fonctions du commutateur Commutateur Fonction Param tres 1 NiMH OFF piles alcalines ON piles rechargeables NiMH AIRFLOW est une marque d pos e de TSI Incorporated A Ne pas tenter de recharger des piles alcalines Utilisation de l adaptateur secteur L adaptateur secteur peut tre utilis pour alimenter l appareil ou pour recharger les piles NiMH lorsque le commutateur DIP dans le compartiment des piles est r gl sur NiMH Si le commutateur DIP est r gl sur Alcalines et si l adaptateur secteur est branch il faut viter d utiliser des piles et l instrument de mesure sera aliment par l adaptateur secteur N oubliez pas de v rifier la tension et la fr quence qui sont inscrites au dos de l adaptateur secteur Entr e d adaptateur secteur Connexion des sondes de ventilateur ou des sondes IAQ Les sondes de ventilateur et IAQ pr sentent un surmoulage en forme de D au niveau du connecteur mini DIN qui doit
6. 16 m s R solution 0 01 m s Taille de la gaine Plage 2 5 1270 cm par incr ments de 0 1 cm D bit volumique Plage la plage varie en fonction de la vitesse de la pression de la taille de la gaine et du facteur K Temp rature sonde TA Plage de 10 60 C Pr cision 0 3 C R solution 0 1 C Humidit relative sonde TA Plage de5 95 Pr cision 3 R solution 0 1 Temp rature de bulbe humide sonde TA Plage de 5 60 C R solution 0 1 C Point de ros e sonde TA Plage de 15 49 C R solution 0 1 C Flux de chaleur sonde TA Plage selon la vitesse la temp rature l humidit et la pression barom trique Mesures disponibles flux de chaleur sensible flux de chaleur latente flux de chaleur totale facteur de chaleur sensible Unit s de mesure BTU h kW 41 Pression statique diff rentielle Plage de 28 28 mm Hg de 3 735 3 735 Pa Pr cision 1 du relev 1 Pa 0 01 mm Hg R solution 0 1 Pa 0 01 mm Hg Pression barom trique Plage de 517 15 930 87 mm Hg Pr cision 2 du relev Plage de temp rature de l instrument Fonctionnement syst me lectronique de 5 45 C Fonctionnement sonde de 10 60 C Stockage de 20 60 C Conditions de fonctionnement de l instrument Altitude de 4 000 m tres maximum Humidit relative de 80 maximum sans condensation Capacit s de sto
7. SAMPLE b 10 Sami A Test 003 12 Sami ih Test 005 Test 005 am Sample 7 Test 006 15 Sam DE Test 007 0 Samj 10 31 10 04 55 03 PM Test 008 0 Sam Test 009 0 Samj DELETE Test010 0 Samples NMa DATES 29 m moire Cette option affiche la quantit de m moire disponible Si vous appuyez sur Supprimer tout sous Supprimer les donn es la m moire est effac e et la quantit de m moire disponible est r initialis e MEMORY INT Test ID 83 Sample 92 ZERO CO Cet article du menu s applique la sonde TSI mod le 982 qui permet de mesurer le monoxyde de carbone CO Z ro CO sert remettre z ro le capteur de CO qui pourrait avoir d riv Le lancement de la fonction Z ro CO sert pr senter la lecture du capteur de CO et le temps restant MENU MI Zero Press Display Setup Settings Flow Setup VOC Setup Applications Calibration ns Bluetooth Functions REMARQUE La fonction Z ro CO doit tre effectu e dans une zone d pourvue de combustion qui pourrait affecter la remise z ro du capteur 30 Chapitre 3 APPLICATIONS Cette option du menu comprend des protocoles de mesures sp cialis s qui servent effectuer divers tests ou des recherches Le menu des applications vous permet de s lectionner une des options suivantes vitesse du courant d air flux de chaleur turbulence air ext rieur et essai d tanch it P
8. ZEROCO EE A AAE A AEE E E EE tirer 30 APPLICATIONS oaea aeaaea rames entente tte eat aaia eaaa 31 CALIBRA GE SR a ne ae ae ir ce 32 BLUETOOTH FUNCTIONS ccccessecessesteceeesseeeseeaeeeeseaeeeesesaeeeeeeaas 32 Discover Devices 32 DISCOVENADIILY adi 5 2 te ra eat near 33 PINCO G sis aissccstessesctsaccutsaaccetcandaadtvecacencanescaivaiacestcardesotsedaccetsads 33 AutoConnects ccc cicacccivasnectivadacdevvasteccuvsdecceddastecevvsdaccctvasaccveass 33 Impression de donn es l aide de l imprimante portable 33 LogDat2 Logiciel de t l chargement ccccceceseeeeeseeeeeees 34 CHAPITRE 4 ENTRETIEN cisiccocesicccceci tect cesistsceciessceccscctececteveccceastds 35 Recalibrage il lites ected Rain ee ead eee 35 MAGGS ia cinco sisi EN AT ARERR 35 SIOCKADE 2 28 an NN NS RM saine ed ede 36 CHAPITRE 5 DEPANNAGE cccccseeceeesseeceenseeeeeenneeeeeenseeeeeenees 39 ANNEXE A CARACTERISTIQUES TECHNIQUES 41 ANNEXE B SONDES A BRANCHER EN OPTION c sseseseseseee 45 Les notes d application indiqu es ici sont disponibles sur le site web de TSI http www tsi com AF 106 Traversing a Duct to Determine Average Air Velocity or Volume AF 107 Using the Models TA465 PVM610 and PVM620 to Measure Pressure AF 109 Converting Standard Velocity to Actual Velocity AF 114 Use of K Factors with TA465 PVM610 and PVM620 AF 124 Heat Flow Calculations AF 138 Percent
9. l appareil vous demande D brancher l instrument pour teindre l unit Pour remettre l appareil en marche branchez l adaptateur secteur ou appuyez sur la touche ON OFF Touches fl ch es Appuyez sur ces touches pour faire d filer les choix AY lors du r glage d un param tre Si vous appuyez simultan ment sur les touches AY le clavier est verrouill il est alors impossible de proc der des r glages non autoris s au niveau des instruments Pour d verrouiller le clavier appuyez simultan ment sur les touches AV 11 Touche Entr e Appuyez sur cette touche pour accepter une s lection une valeur ou une condition du menu Dans le mode Continu touche appuyez sur cette touche pour D marrer ou Arr ter l enregistrement des donn es Touches fl ch es lt ou gt et Menu Appuyez sur les touches fl ch es pour modifier les choix lors du r glage d un param tre Appuyez sur la touche d envoi Menu pour s lectionner un des menus Pression z ro Configuration de l affichage Param tres Configuration du flux Configuration des COV Configuration actuelle std Enregistrement des donn es R initialisation CO Applications Calibrage et Bluetooth Functions Glossaire Plusieurs termes sont utilis s diff rentes reprises dans le pr sent manuel Vous trouverez ci dessous une br ve explication concernant la signification de ces termes Echantillon Regr
10. temps et vous ne pouvez pas non plus en r gler une sur PRIMAIRE et l autre sur ON Une seule peut tre sur ON un quelconque moment donn Mode de d enregistrement Le TA465 peut tre programm pour stocker des mesures en m moire Les types de mode d enregistrement disponibles sont les suivants e Manuel e Enregistrement automatique e Continu touche e Continu temps Utilisation 19 20 Enregistrement manuel Le mode Manuel n enregistre pas automatiquement les donn es ll invite plut t l utilisateur Enregistrer un chantillon ou utiliser la touche ESC pour ne pas enregistrer Pour d marrer l enregistrement appuyez sur la touche lt 4 REMARQUE Pour r gler la p riode moyenne d un chantillon modifiez la constante de temps augmentation ou diminution en secondes qui se trouve dans le menu Param tres DATA LOGGING_ IIIe Measurements LOG MODE IE Log oa eae Log Settings Manual Choose Test Auto save Name Test Cont key View Data Cont time Delete Data Memory lt gt Enregistrement automatique En mode d Enregistrement automatique l utilisateur pr l ve des chantillons qui sont automatiquement enregistr s dans la m moire la fin de la p riode d chantillonnage Pour d marrer l enregistrement appuyez sur la touche lt 4 DATA LOGGING_ TITTE Measurements LOG MODE F Log Mod Log Settings Manual Choose Test Auto save N
11. une mesure dans une conduite reportez vous la Note d application AF 106 REMARQUE Si aucune sonde permettant de mesurer la temp rature sonde brancher ou thermocouple n est connect e Source temp doit tre r gl sur entr La temp rature d air de la conduite doit alors tre saisie manuellement par l utilisateur en utilisant le param trage Temp entr e Si Temp Source est sur sonde ou thermocouple 1 et 2 et si aucune sonde n est connect e des tirets apparaissent l cran Pour plus d informations sur la saisie manuelle de la temp rature voir la section R glage r el standard de ce manuel Installation sn Admission pression g n rale Admission pression statique Raccord de pression statique pour saisie sur manom tre Raccord de pression g n rale pour saisie sur di manom tre Ne pas utiliser l instrument ou les sondes proximit de sources de tension dangereuses qui pourraient provoquer des blessures graves Chapitre 2 Capteurs thermocouple L instrument de mesure s rie TA465 comprend deux capteurs thermocouple sa base Il est possible d y fixer n importe quel thermocouple type K dot d un mini connecteur Voir Configuration de l affichage pour le r glage des relev s de temp ratures du thermocouple et le choix de l affichage TC1 TC2 ou TC1 TC2 Connexion des thermocouples Le thermocouple typ
12. Outdoor Air Calculation and Its Use AF 141 Turbulence Intensity Measurements AF 142 Draft Rate A Determining Factor in the Quantification of Human Comfort AF 147 Photo lonization Detection PID Technology AF 150 Using Bluetooth Communications Chapitre 1 D ballage et identification des pi ces D ballez soigneusement l instrument et les accessoires pr sents dans l emballage d exp dition V rifiez les pi ces l aide de la liste de composants ci dessous Si un l ment manque ou est endommag informez imm diatement TSI 1 Malette de transport Instrument Embout de pression statique uniquement mod le TA465 P Tube en caoutchouc uniquement mod le TA465 P C ble USB CD ROM LogDat avec logiciel de t l chargement Adaptateur secteur 3 QG a R Cette page a t laiss e vide intentionnellement Chapitre 1 Chapitre 2 Installation Alimentation du mod le s rie TA465 L instrument de mesure de la vitesse de l air AIRFLOW mod le TA465 peut tre aliment de deux mani res l aide de quatre piles AA ou d un adaptateur secteur Installation des piles Ins rez quatre piles AA comme indiqu sur le sch ma situ l int rieur du compartiment des piles Le mod le TA465 est con u pour fonctionner avec des piles rechargeables NiMH ou alcalines Si vous utilisez des piles NiMH leur dur e de vie sera moins importante Si vous utilisez des piles NiMH
13. VENDEUR DE LA REPARATION OU DU REMPLACEMENT DES PRODUITS DANS LE CAS D UN LOGICIEL LE VENDEUR REPARERA OU REMPLACERA LE LOGICIEL DEFECTUEUX OU S IL EST INCAPABLE DE LE FAIRE REMBOURSERA LE PRIX D ACHAT DU LOGICIEL DANS LE CAS D UN LOGICIEL LE VENDEUR REPARERA OU REMPLACERA LE LOGICIEL DEFECTUEUX OU S IL EST INCAPABLE DE LE FAIRE REMBOURSERA LE PRIX D ACHAT DU LOGICIEL LE VENDEUR NE PEUT EN AUCUN CAS ETRE TENU RESPONSABLE DES MANQUES GAGNER OU DE QUELQUE DOMMAGE SPECIAL ACCESSOIRE O INDIRECT LE VENDEUR NE PEUT SOUS AUCUNE CIRCONSTANCE TRE TENU RESPONSABLE DES MANQUES GAGNER OU DE QUELQUE DOMMAGE SPECIAL ACCESSOIRE OU INDIRECT LE VENDEUR DECLINE TOUTE RESPONSABILITE ENVERS D EVENTUELS COUTS OU FRAIS D INSTALLATION DE DEMONTAGE OU DE REINSTALLATION Aucune action l gale ne peut tre intent e contre le vendeur sous quelque forme que ce soit au dela d un d lai de 12 mois apr s la cause de l action Les produits retourn s sous garantie l usine du vendeur seront envoy s aux risques de l acheteur et seront retourn s ce dernier par le vendeur au risque du vendeur Il sera consid r que l acheteur et tous les utilisateurs ont accept ce document de LIMITATION DE GARANTIE ET DE RESPONSABILITE lequel contient l int gralit de la garantie limit e exclusive du vendeur Ce document de LIMITATION DE GARANTIE ET DE RESPONSABILITE ne peut tre amend modifi ou faire l objet d une renonciation de droit quelconque autr
14. aeeeeneeees 9 Connexion des thermocouples 9 Connexion de l imprimante portable Bluetooth en option 10 Connexion UN ordinateur 10 CHAPITRE 3 UTILISATION csscccssccessseeesseeenseeeesseeessenenseeenses 11 Fonctions du Clavier urine AE tale 11 GlOSSalre law site aa hia a di ee di ie 12 MENUS ESS se a a a tlt a hte a ale att A a i aha tad 13 PRESSION ZERO ZERO PRESS 13 CONFIGURATION DE L AFFICHAGE DISPLAY SETUP 14 PARAMETRES SETTINGS 15 CONFIGURATION DU FLUX FLOW SETUP cc eecesecsseeeesseeeseeeesnees 15 CONFIGURATION DES COV VOC SETUP 18 CONFIGURATION ACTUELLE STANDARD ACTUAL STD SETUP 18 ENREGISTREMENT DES DONNEES data logging 2 19 M SUr S 52e aaa a a aaea aeaa a A anse aa te degree it ones ana 19 Mode de d enregistrement 19 CNOISIT IG tests E P A T dater sates ete die 24 Nommer le tests tirmhesrinderdmmirnn rmiituetereiene 25 Afficher donn es nest heser sreienter teste 25 Afficher statistiques 0 cccccceeesceceeeeeeeeeeeeseeseeeeesaeeesaeeeeeeeeeas 26 Afficher chantillons ccccceesseceeeesteeeeeaeeeesenaeeeesssaeeeeseeaes 27 Imprimer l tast arrere er as an anni retiens ENEN 27 Supprimer les donn es ceccceceeeeeeeeeeeeneeeeeeeeceeeeetaeeeeaeeeeaes 28 So M MOITR I A E E EEA 30
15. ame Test Cont key View Data Cont time Delete Data Memory lt gt Chapitre 3 En r glant sur Enregistrement automatique la dur e d chantillon peut tre ajust e La dur e d chantillon est la p riode pendant laquelle l chantillon sera pr lev en moyenne UP DATA LOGGING IE Measurements SAMPLE TIME Log Mode Ayes Log Settings Choose Test Test 0 00 05 Name Test Min Sec View Data Delete Data Memory Enregistrement continu touche En mode Continu touche l utilisateur commence la journalisation a l aide de la touche L instrument ne cesse de prendre des mesures que lorsque vous appuyez de nouveau sur la touche 1 DATA LOGGING MME Measurements Log Mod Log Settings Choose Test Name Test View Data Delete Data Memory LOG MODE II Manual Auto save Cont key Cont time lt Utilisation 21 En r glant sur Cont touche l intervalle d enregistrement et la longueur du test peuvent tre ajust s DATA LOGGING Choose Test Name Test View Data Delete Data Memory QE Los hote el LOG SETTINGS Log Mode Contfkel Log Settings Log Interval Test 0d 00 LOG INTERVAL IE 00 05 Min Sec lt gt REMARQUE Si vous appuyez simultan ment sur les touches AY le clavier est verrouill il est alors impossible de proc der a des r glages non autoris s au
16. ckage des donn es Plage plus de 26 500 chantillons et 100 tests ID un chantillon peut contenir 14 types de mesures Intervalle d enregistrement Intervalles de 1 seconde 1 heure Constante de temps Intervalles pouvant tre s lectionn s par l utilisateur Temps de r ponse Vitesse 200 msec Temp rature 2 minutes jusqu 66 de la valeur finale Pression 0 1 msec Humidit lt 1 minute jusqu 66 de la valeur finale Dimensions externes de l appareil de mesure 9 7 cm x 21 1 cm x 5 3 cm Dimensions de la sonde de mesure Longueur de la sonde 101 6 cm Diam tre de l embout de la sonde 7 mm Diam tre de la base de la sonde 13 mm Dimensions de la sonde d articulation Longueur de la section d articulation 15 24 cm Diam tre du joint d articulation 9 5 mm Poids de l appareil de mesure Poids avec les piles 0 36 kg 42 Annexe Exigences lectriques Quatre piles AA incluses ou un adaptateur secteur p n 801761 Entr e de 90 240 Vac de 50 60 Hz Sortie 9 VDC 2A Temp rature compens e sur une plage de temp ratures d air comprise entre 5 et 65C La pr cision de 3 du relev ou 0 015 m sec selon la valeur la plus lev e s applique de 0 15 50 m sec 3 Les mesures de vitesse par pression ne sont pas recommand es lorsque la vitesse est inf rieure 5 m sec et sont particuli rement adapt es aux vitesses de plus de 10
17. document crit du vendeur le vendeur n offre aucune garantie et d cline toute responsabilit concernant les produits incorpor s dans d autres produits ou quipements ou qui sont modifi s par toute autre personne que le vendeur Les l ments susmentionn s REMPLACENT toute autre garantie et sont soumis aux LIMITATIONS indiqu es CONCERNANT L INFRACTION DU VENDEUR LA GARANTIE IMPLICITE CONTRE TOUTE INFRACTION LADITE GARANTIE EST LIMIT E AUX PLAINTES POUR INFRACTION DIRECTE ET EXCLUT LES PLAINTES POUR INFRACTIONS INDUITES OU CONTRIBUTIVES CONCERNANT L INFRACTION DU VENDEUR LA GARANTIE IMPLICITE CONTRE TOUTE INFRACTION LADITE GARANTIE EST LIMIT E AUX PLAINTES POUR INFRACTION DIRECTE ET EXCLUT LES PLAINTES POUR INFRACTIONS CONTRIBUTIVES OU INDUITES LE SEUL RECOURS DE L ACHETEUR SERA LE RETOUR DU PRIX D ACHAT AVEC REMISE POUR UNE USURE SUFFISANTE OU LE REMPLACEMENT DES PRODUITS PAR DES PRODUITS NON COUPABLES D INFRACTION A LA DISCRETION DU VENDEUR SOUS RESERVE DES LOIS EN VIGUEUR LES SEULS RECOURS A LA DISPOSITION DE L UTILISATEUR OU DE L ACHETEUR AINSI QUE LES LIMITES DE RESPONSABILITE DU VENDEUR CONCERNANT TOUTES PERTES BLESSURES OU DOMMAGES ASSOCIES AUX PRODUITS COMPRENANT LES RECLAMATIONS BASEES SUR UNE OBLIGATION CONTRACTUELLE UNE NEGLIGENCE UN PREJUDICE UNE RESPONSABILITE STRICTE OU AUTRE NE PEUVENT ALLER AU DELA DU RETOUR DES PRODUITS AU VENDEUR SUIVI D UN REMBOURSEMENT DE LEUR PRIX D ACHAT OU ALA DISCRETION DU
18. ds Pour t l charger des donn es du mod le TA465 connecter le cable USB fourni d interface avec l ordinateur au mod le TA465 et un port USB de l ordinateur Tout port USB peut tre utilis 34 Chapitre 3 Chapitre 4 Entretien Le mod le TA465 et accessoires de sonde ne n cessite que tr s peu d entretien pour fonctionner de mani re correcte Recalibrage Afin de b n ficier de mesures d un haut niveau de pr cision nous vous recommandons de retourner le mod le TA465 sondes 960 IAQ et VOC TSI pour un recalibrage annuel Veuillez contacter un des bureaux TSI ou votre distributeur local pour d cider de la date d entretien et pour recevoir un num ro d autorisation de retour du mat riel Pour remplir un formulaire de demande de retour du mat riel en ligne consultez le site Web de TSI l adresse http service tsi com TSI Instruments Ltd Stirling Road Cressex Business Park High Wycombe Bucks HP12 3ST United Kingdom T l 44 0 149 4 459200 Fax 44 0 149 4 459700 Le mod le TA465 et accessoires de sonde peut galement tre recalibr sur site l aide du menu de CALIBRAGE Ces r glages sur site ont pour objectif de modifier l g rement le calibrage en fonction des normes de calibrage de l utilisateur Ils n ont PAS pour objectif de remplacer le calibrage complet Pour un calibrage complet points multiples et une certification l instrument doit tre renvoy en usine Mal
19. e K dot d un mini connecteur poss de une borne plus large que l autre La borne plus large doit tre ins r e au bas du port de connexion TC1 ou TC2 Thermocouple type K Pour les thermocouples provenant d un fournisseur autre que TSI il convient d isoler lectriquement la gaine A m tallique des fils l int rieur Le non respect de cette exigence peut entra ner des erreurs de relev s un choc lectrique ou un risque d incendie sources de tension dangereuses qui pourraient rovoquer des blessures graves Ne pas utiliser l instrument ou les sondes proximit de Installation 9 Connexion de l imprimante portable Bluetooth en option Pour connecter l imprimante Bluetooth au mod le TA465 mettez l appareil et l imprimante sous tension S lectionnez ensuite la touche MENU Dans le menu utilisez les boutons A et Y pour mettre l option de Bluetooth Functions en surbrillance et appuyez sur la touche Surligner Discover Devices et appuyez sur la touche Si d autres imprimantes Bluetooth TSI se trouvent dans la zone mettez les hors tension avant de lancer la recherche Le mod le TA465 recherche et r pertorie alors l ensemble des p riph riques Bluetooth disponibles Pour plus d informations sur l tablissement de connexions Blue Tooth voir applications TSI note AF 150 Connexion a un ordinateur Utilisez le c ble USB d interface d ordinateur fourni avec le mod le TA465 pour con
20. ement que par crit avec la signature d un dirigeant du vendeur Politique de service apr s vente Sachant que des instruments d fectueux ou ne fonctionnant pas correctement sont pr judiciables TSI et ses clients notre politique de service apr s vente a t con ue pour r soudre rapidement tous les probl mes Si un dysfonctionnement est constat veuillez prendre contact avec votre antenne commerciale ou repr sentant le plus proche ou appelez le service clients au 800 874 2811 Etats Unis ou 1 651 490 2811 autres pays TABLE DES MATIERES CHAPITRE 1 DEBALLAGE ET IDENTIFICATION DES PIECES 1 CHAPITRE 2 INSTALLATION cccscscssseesseeenseeeesseeesssnenseenenseees 3 Alimentation du mod le s rie TA465 3 Installation des piles 3 Param tres du commutateur DIP nennen 3 Utilisation de l adaptateur secteur 4 Connexion des sondes de ventilateur ou des sondes IAQ 4 Utilisation des sondes t lescopiques du thermo an mom tre 5 D ploiement de la sonde 5 R tractation de la sonde cccceccseceeeesteeeeeseeeeseseeeesenaeeeeseaaes 5 Utilisation des capteurs de pression TA465 P 6 Connexion de la sonde de pression statique ceeee 6 Connexion d une sonde Pitot ou sonde de d bit d air pitot rectiligne en option 7 Capteurs thermocouple c cccccceceeeeeeeeeeeseeseeeeeseaeeeea
21. ettes Si la malette de l instrument ou la housse de stockage a besoin d tre nettoy e essuyez la l aide d un chiffon doux et d alcool isopropylique ou d un produit d tergent doux N immergez jamais le mod le TA465 Si le bo tier du mod le TA465 ou l adaptateur secteur est cass il doit tre imm diatement remplac afin d emp cher tout acc s des tensions dangereuses 35 Stockage Retirez les piles lors du stockage de l appareil pendant une p riode de plus d un mois afin d viter toute d t rioration li e une fuite des piles 36 Chapitre 4 Utilisation Cette page a t laiss e vide intentionnellement 37 Chapitre 5 D pannage Le tableau 5 1 r pertorie les sympt mes les causes possibles et les solutions recommand es pour les probl mes fr quemment rencontr s avec le mod le TA465 Si le sympt me auquel vous tes expos n est pas r pertori ou si aucune des solutions propos es ne vous permet de r soudre le probl me veuillez contacter TSI Tableau 5 1 d pannage du mod le TA465 Sympt me Causes possibles Mesure corrective Aucun affichage L appareil n est pas Mettez l appareil sous sous tension tension Piles puis es ou Remplacez les piles ou quasiment puis es branchez l adaptateur secteur Bornes des piles Nettoyez les bornes des sales piles Instabilit des relev s Flux fluctuant Repositionnez la sonde de vitesse dans un flux moins turbu
22. f rer a la Note d application AF 109 MENU wits SETTING ir Zao tress ACTUAL STD Semere Display Setup etting Standard da Settings Temp source Entered Flow Setup Se VOC Setup TEMP SOURCE NI Actual Std Setu EnteredTemp 70F Data Logging lt As Zero CO Thermocouple 2 Applications E Calibration Bluetooth Functions 18 Chapitre 3 Mesures ENREGISTREMENT DES DONNEES data logging Les mesures enregistrer en m moire ne d pendent pas des mesures affich es l cran et doivent donc tre s lectionn es dans le menu d Enregistrement des donn es gt Mesures e Enr glant sur ON la mesure sera enregistr e en m moire e Enr glant sur AFFICHAGE la mesure sera enregistr e en m moire si elle est visible sur l cran principal actif e Enr glant sur OFF la mesure ne sera pas enregistr e en m moire MENU M Zero Press Depay Sep gDATALOGGING M Settings Log Mode Cont gt MEASUREMENTSIIIIIP Flow Setup PNEC a Log Setti Temperature DISPLAY VOC Setup og Settings i Velocity DISPLAY Choose Test Test Actual Std Setu Flow DISPLAY Data Loggin Name Test gging Vi Heatflow OFF Zero CO iew Data P ressure DISPLAY Applications D elete Data Baro Press ON Calibration Memory Bluetooth Functions lt ON DISPLAY OFF REMARQUE La vitesse Pitot et la vitesse de la sonde AF ne peuvent pas tre toutes les deux sur ON en m me
23. humidit CO and CO Sondes de compos s organiques volatils VOC Description 984 VOC basse concentration parties par milliard et temp rature 985 VOC haute concentration parties par million et temp rature 986 VOC basse concentration parties par milliard temp rature CO et humidit 987 VOC haute concentration parties par million temp rature CO2 et humidit Sondes de thermocouple alliage K Description 792 Sonde de temp rature de surface 794 Sonde de temp rature d air 45 Sondes Pitot Model 634634000 Sonde Pitot 12 30 cm diam tre 5 16 8 mm 634634001 Sonde Pitot 18 46 cm diam tre 5 16 8 mm 634634002 Sonde Pitot 24 61 cm diam tre 5 16 8 mm Sonde Pitot 36 91 cm diam tre 5 16 8 mm 634634003 Sonde Pitot 60 152 cm diam tre 5 16 8 mm 634634005 Sonde Pitot t lescopique 8 38 20 cm 96 cm 634634004 Sonde de flux d air Pitot droite 18 46 cm diam tre 5 16 8 mm 800187 Sonde Pitot 12 30 cm diam tre 5 16 8 mm 46 Appendix B AIRFLOW INSTRUMENTS Airflow Instruments TSI Instruments Ltd Visit our website at www airflowinstruments co uk for more information UK Tel 44 149 4 459200 Germany Tel 49 241 523030 France Tel 33 491 11 87 64 P N 6005363 Rev D FR 2014 TSI Incorporated Printed in U S A
24. ion facile et une configuration de l instrument en utilisant les touches fl ch es et la touche 1 Pour quitter un menu ou un article de menu appuyez sur la touche ESC e Pour acc der aux articles du menu appuyez sur la touche d envoi Menu e Pour s lectionner un param tre utilisez les touches fl ch es pour mettre la s lection en surbrillance et appuyez sur la touche MENU MF Zero Press Display Setup Settings Flow Setup VOC Setup Actual Std Setup Data Logging Zero CO Applications Calibration Bluetooth Functions PRESSION ZERO ZERO PRESS Pour r initialiser la pression laissez les p les positif et n gatif l air libre et s lectionnez le menu de Pression Z ro Le capteur de pression doit tre remis z ro apr s la configuration initiale et v rifi p riodiquement L instrument indiquera si la r initialisation s est d roul e correctement Utilisation 13 CONFIGURATION DE L AFFICHAGE DISPLAY SETUP Le menu de Configuration de l affichage vous permet de s lectionner les param tres que vous souhaitez afficher l cran Lorsqu un param tre est mis en surbrillance vous pouvez utiliser la touche ON pour activer son affichage l cran ou la touche OFF pour d sactiver ce param tre Utilisez la touche PRIMAIRE pour afficher le param tre l cran dans un format agrandi Un total de 5 param tres peut tre affich l cran 1 primaire grande police et 4 secondaires
25. lage appara t sur l cran Pour d verrouiller le clavier appuyez simultan ment sur les touches A V Le symbole verrouillage dispara t Utilisation 23 24 Choisir le test Les tests ID correspondent un groupe d chantillons qui sont utilis s pour tablir des statistiques moyenne minimum et maximum d une application de mesure Le TA465 peut stocker plus de 26 500 chantillons et 100 tests ID un chantillon peut contenir 14 types de mesure Exemple chaque travers e de conduit a son propre test ID compos de plusieurs chantillons Appuyez sur NOUVEAU NEW pour acc der au prochain test ID disponible L option DATES DATES vous donne la liste des dates auxquelles le test a t effectu Measurements Log Mode Log Settings Choose Test Name Test View Data Delete Data Memory lt DATA LOGGING Mk Cont Test O CHOOSE TEST Test 001 9 Samples Test 002 7 Samples Test 003 0 Samples Test 004 0 Samples Test 005 0 Samples Test 006 0 Samples Test 007 0 Samples Test 008 0 Samples Test 009 0 Samples Test 010 0 Samples Ve NEW DATES Chapitre 3 Nommer le test Cette option permet de personnaliser le nom du test ID en utilisant 8 caract res maximum Utilisez les touches fl ch es pour d placer le curseur vers un emplacement souhait appuyez sur pour accepter R p tez cette op ration jusqu l obtention du nom voulu Appuyez sur SAVE p
26. lent ou utilisez une constante de temps plus longue Aucune r ponse du Clavier verrouill D verrouillez le clavier en clavier appuyant simultan ment sur les touches AV Message d erreur de M moire pleine T l chargez les donn es l instrument souhait es puis EFFACEZ TOUTE la m moire Anomalie au niveau Entretien usine requis au de l instrument niveau de l instrument Message d erreur de Anomalie au niveau Entretien usine requis au la sonde de la sonde niveau de la sonde La sonde est La sonde a t Eteignez l instrument puis branch e mais branch e quand rallumez le l instrument ne la l instrument tait en reconna t pas marche 39 Retirez imm diatement la sonde en cas de temp ratures excessives une chaleur excessive peut endommager le capteur Les seuils de temp ratures de fonctionnement sont d taill s dans l annexe A Caract ristiques techniques Le capteur de pression est prot g des d t riorations lorsque la pression est inf rieure 7 psi 48 kPa ou 360 mmHg En cas de pression plus lev e il risque d exploser 40 Chapitre 5 Annexe A Caract ristiques techniques Les caract ristiques techniques peuvent tre modifi es sans pr avis Vitesse sonde TA Plage de 0 50 m s Pr cision 3 du relev ou 0 015 m s selon la valeur la plus lev e R solution 0 01 m s Vitesse tube de Pitot Plage de 1 27 78 7 m s Pr cision 1 5 10
27. m sec La plage peut varier en fonction de la pression barom trique A La pr cision correspond la conversion de la pression en vitesse La pr cision de la conversion est meilleure lorsque les valeurs de pression augmentent gt Pr cision avec la housse de l instrument 25 C ajoutez une marge de 0 03 C C pour prendre en compte les modifications au niveau de la temp rature de instrument 2 Pr cision avec une sonde a 25 C Ajoutez une marge de 0 2 d humidit relative C pour prendre en compte les modifications au niveau de la temp rature de la sonde Inclut 1 d hyst r sis Plage de surpression 7 psi 360 mmHg 48 kPa Caract ristique techniques 43 44 Cette page a t laiss e vide intentionnellement Annexe Annexe B Sondes brancher en option Sondes thermoan mom tre Description 960 Vitesse et temp rature de l air sonde droite 962 Vitesse et temp rature de l air sonde articul e 964 Vitesse temp rature et humidit de l air sonde droite 966 Vitesse temp rature et humidit de l air sonde articul e Sondes an mom tre vanne rotative Model Description 995 Vanne rotative de 4 pouces 100 mm vitesse et temp rature de lair Sondes de qualit d air int rieur IAQ 980 Description Sonde de qualit d air int rieur temp rature humidit CO 982 Sonde de qualit d air int rieur temp rature
28. n et la touche pour accepter les param tres MENU TTF Zero Press Display Setup 77 SETTINGS III Settings ad English eeper Disable Flow Setup Select Units VOC Setup Time Constant 1 Second Actual Std Setup Contrast 5 Data Logging Set Time 09 14 AM Zero CO Set Date 10 31 08 Applications Time Format 12 hr Calibration Date Format MM DD YY Number Format XX XXX YY Bluetooth Functions Backlight Age Auto Off Enable Bet Nes CONFIGURATION DU FLUX FLOW SETUP 6 types de mode de Configuration du flux sont disponibles gaine circulaire gaine rectangulaire zone de la gaine Pressure facteur K c ne et Air Cone Utilisez les touches d envoi lt ou gt pour faire d filer les types puis appuyez sur la touche pour accepter le type souhait Pour modifier la valeur mettez l option de Saisie des param tres en surbrillance et appuyez sur la touche MENU LE FLOWTYPE III Zero Press x FLOW SETU Round duct Display Setup Flow Type Round Duct Rectduct Settings Enter Settings Ductarea Flow Setup Press Kfact VOC Setup joue Actual Std Setup Data Loggin cn ENTER SETTINGS P Applications Calibration Bluetooth Functions 12 0 in dia lt gt Utilisation 15 La Gaine ronde la Gaine rectangulaire et la Zone de la gaine sont utilis es pour effectuer une travers e de conduit l aide d une sonde Pitot ou d une sonde de thermo an mom tre Si
29. necter l instrument un ordinateur dans le but de t l charger des donn es stock es gt lt Port de communication USB Ce symbole indique que le port de donn es du mod le TA465 n est pas con u pour la connexion un r seau de t l communications public Connectez uniquement le port de donn es USB un autre port USB sur un dispositif informatique certifi La protection offerte par l instrument pourrait tre compromise si celui ci est utilis d une mani re autre que celles sp cifi es dans ce manuel d utilisateur Bluetooth est une marque d pos e de Bluetooth SIG 10 Chapitre 2 Chapitre 3 Utilisation Raccord de pression F E Messages compl mentaires Indicateur de batterie AIRFLOW Affichage d activit Param tres b do Indicateurs touches Param tres d affichage secondaies Touchesd affichages Fonctions du clavier Touche ON OFF Appuyez sur cette touche pour mettre le mod le TA465 sous hors tension Lors de la s quence de d marrage l cran affiche les informations suivantes num ro du mod le num ro de s rie et version du logiciel Pour teindre l appareil appuyez et maintenez la touche ON OFF pendant 3 secondes L instrument compte rebours OFF2 OFF1 OFF Si l adaptateur secteur est connect la touche ON OFF est d riv e Si la touche ON OFF est enfonc e alors que l adaptateur secteur est connect
30. niveau des instruments pendant un enregistrement sans surveillance Un symbole Verrouillage appara t sur l cran Pour d verrouiller le clavier appuyez simultan ment sur les touches A V Le symbole verrouillage disparait Enregistrement continu temps En mode Continu temps l utilisateur lance la prise de mesures a l aide de la touche L instrument ne cesse de pr lever des chantillons qu une fois que la p riode d finie dans Longueur du test est coul e DATA LOGGING ME Measurements Log Mod Log Settings Choose Test Name Test View Data Delete Data Memory LOGMODE Iz Manual Auto save Cont key Cont time lt 22 Chapitre 3 En r glant sur Cont temps l intervalle d enregistrement et la longueur du test peuvent tre ajust s DATA LOGGING Measurements Log Mode Log Settings Choose Test Name Test View Data Delete Data Memory Cort ti Test Log Interval Test Length lt 00 05 Min Sec LOG SETTINGS LOG INTERVAL Ir oot 00 01 00 00 01 gt TEST LENGTH lt 00 00 05 Day Hour Min M gt REMARQUE Si vous appuyez simultan ment sur les touches AY le clavier est verrouill il est alors impossible de proc der des r glages non autoris s au niveau des instruments pendant un enregistrement sans surveillance Un symbole verrouil
31. on pr programm e Les num ros de c nes correspondent aux mod les de c nes Par exemple 100 fait r f rence un c ne dont le num ro de mod le est AM 100 Seuls les c nes disposant des num ros de mod le suivants peuvent tre utilis s avec cette fonction AM 100 AM 300 AM 600 et AM 1200 Lors de la s lection d un num ro de mod le de c ne l instrument retourne en mode de mesure et utilise une courbe pr programm e pour calculer le d bit partir de la vitesse lors de Utilisation 17 l utilisation d une sonde de thermo an mom tre La s lection du d flecteur s applique l an mom tre h lice mod le 995 et au kit de d flecteur r f AFL72852201 CONFIGURATION DES COV VOC SETUP Cet article du menu s applique aux sondes TSI qui mesurent les compos s organiques volatils COV Veuillez vous r f rer au manuel d utilisation des sondes COV portant les num ros de r f rence 984 985 986 et 987 que vous trouverez ci joint CONFIGURATION ACTUELLE STANDARD ACTUAL STD SETUP S lectionnez les mesures et les param tres R els Standard dans le menu de configuration Act Std Le mod le TA465 mesure la pression barom trique r elle en utilisant un capteur interne La source de temp rature peut tre saisie manuellement ou prise l aide d une sonde qui mesure la temp rature brancher une sonde ou un thermocouple Pour plus d informations sur les conditions r elles et standard se r
32. ons sur l tablissement de connexions Bluetooth reportez vous la note d application AF 150 de TSI Supprimer les donn es Utilisez cette option pour supprimer l ensemble des donn es un test ou un chantillon DATA LOGGING IE Measurements Log Mode Cont ti Log Settings Choose Test Name Test View Data Delete Data Memory DELETE DATA F Delete All Delete Test TgSt 00 Delete Sample lt gt Supprimer tout Delete All sert effacer les donn es stock es dans tous les tests ID DELETE DATA Delete All DELETE ALL MM Delete Test Delete Sample Are you sure YES NO Chapitre 3 Supprimer test Delete Test sert effacer les donn es stock es dans un certain test ID s lectionn par l utilisateur DELETE DATA Delete All Delete Test Delete Sample DELETE TEST III gt DELETE TEST YES ME Delete Test 005 Are you sure NO Test 001 14 Samp Test 002 10 Samg Test 003 12 Samg Test 004 8 Samp Test005 75e Test 006 15 Samp Test 007 0 Samp Test 008 0 Samp Test 009 0 Samp Test 010 0 Samples AV DATES Supprimer chantillon Delete Sample sert effacer le dernier chantillon dans un certain test ID s lectionn par l utilisateur DELETE DATA Delete All Delete Test A est 001 Delete Sample Test oe Utilisation TUE DELETE SAMPLE MTh 14Samj DELETE
33. oupe l ensemble des param tres de mesure stock s simultan ment Test ID Groupe d chantillons Les statistiques moyenne minimum maximum et d compte sont calcul es pour chaque test ID Le nombre maximal de tests ID est de 100 Constante de temps La constante de temps correspond une p riode d int gration Elle permet de ralentir l affichage En cas de fluctuations au niveau des flux une constante de temps plus longue permet de ralentir les fluctuations L cran est mis jour toutes les secondes le relev affich correspond cependant la moyenne de la derni re p riode de la constante de temps Par exemple si la constante de temps est de 10 secondes l cran est mis jour toutes les secondes mais le relev affich correspond la moyenne des 10 derni res secondes La constante de temps est galement appel e moyenne mobile Intervalle d enregistrement L intervalle d enregistrement correspond la fr quence laquelle l instrument enregistre les relev s Par exemple si l intervalle d enregistrement est r gl sur 30 minutes chaque chantillon correspond la moyenne des 30 derni res minutes 12 Chapitre 3 Longueur du test Ce terme correspond au temps pendant lequel les donn es sont enregistr es dans le mode Continu temps du menu Enregistrement des donn es Menus La structure du menu est organis e pour permettre une navigat
34. our m moriser le nom ID personnalis DATA LOGGING Measurements Log Mode Cont Log Settings Choose Test NAME TEST Mp TS112345 Test 00 9 123456789 hatin ABCDEFGH J iew Data KLMNOPQRST Delete Data UVWXYZ_ Memory lt gt lt SAVE gt Afficher donn es Choisir le test Pour afficher les donn es m moris es s lectionnez d abord le test ID qui contient les donn es r cup rer Cette action s effectue dans le menu Choisir le test DATA LOGGING TIIIF Measurements VIEW DATA Log Mode Auto sa Choose Test Testoq gt CHOOSE TEST ff L in View Stats Test 001 9 Samples rte ce en View Samples Test 002 7 Samples Print Test Test 003 0 Samples Name Test Test 004 0 Samples View Data Test 005 0 Samples Delete Data Test 006 0 Samples 5 Test 007 0 Samples Memory Test 008 0 Samples Test 009 0 Samples Test 010 0 Samples AV pes DATES Utilisation 25 Afficher statistiques Affiche les statistiques moyenne minimum et maximum d un test ID choisi ainsi que le nombre d chantillons la date et l heure du pr l vement des chantillons DATA LOGGING IT Measurements Log Mode Auto s VIEW DATA M Choose Test Test 001 Log Settings View Stats Choose Test est og View Samples Name Test Print Test View Data Delete Data Memory Utilisez les fl ches gauche et droite pour afficher les stati
35. our plus d informations sur ces applications reportez vous aux informations suivantes Vitesse du courant d air Note d application AF 142 Flux de chaleur Note d application AF 124 Intensit de la turbulence Note d application AF 141 Pourcentage air ext rieur Note d application AF 138 Essai d tanch it Manuel PANDA MENU Zero Press Display Setup Settings Flow Setup VOC Setup Actual Std Setup Data Logging Zero CO Applications Calibration Bluetooth Functions M raft Rate Heatflow Turbulence Outside Air Leakage Test APPLICATIONS UMH Utilisation 31 CALIBRAGE Le menu Calibrage r pertorie les param tres de mesure pouvant tre ajust s sur le terrain Les sondes d montables appropri es doivent tre fix es au TA465 avant d entreprendre un talonnage sur le terrain l exception de la pression et la pression barom trique qui ne peuvent pas tre soumises un talonnage Pour plus d informations sur la r alisation des talonnages sur le terrain reportez vous la Note d application AF 146 de TSI MENU HE Zero Press Display Setup CALIBRATION F Settings ibrate Temp Flow Setup alibrate Vel VOC Setup Calibrate RH Actual Std Setup Calibrate B P Data Logging Calibrate CO2 Zero CO Calibrate CO Applications Calibrate VOC Calibration Restore Factory Cal Bluetooth Functions BLUETOOTH FUNCTIONS The AIRFLOW Instrumen
36. ram tres sont compris entre 0 et 5 fois Pour plus d informations sur l tablissement des connexions Bluetooth reportez vous la Note d application AF 150 de TSI Impression de donn es l aide de l imprimante portable Pour imprimer les donn es journalis es acc dez au menu d ENREGISTREMENT DES DONNEES Utilisez ensuite l l ment CHOISIR LE TEST pour s lectionner les donn es imprimer Une fois le test s lectionn utilisez les l ments AFFICHER STATISTIQUES et AFFICHER ECHANTILLONS pour s lectionner les statistiques ou les points de donn es afficher et imprimer Une fois l option AFFICHER STATISTIQUES ou AFFICHER ECHANTILLONS s lectionn e appuyez sur la touche d impression pour imprimer les donn es Utilisation 33 LogDat2 Logiciel de t l chargement Le mod le AIRFLOW TA465 comprend aussi un logiciel de t l chargement appel LogDat2 Le logiciel LogDat2 transf re les donn es sauvegard es du mod le TA465 vers un ordinateur sous forme de tableur Ce logiciel est utile pour des applications comme le test des travers es de conduites la hotte fum e et le test de vitesse de la face filtrante Suivre les instructions de l tiquette du logiciel LogDat2 pour l installer sur votre ordinateur Ce programme est fourni sur CD ROM et comprend un guide d utilisateur et des instructions d installation Des mises jour sont disponibles sur le site TSI l adresse http Awww tsi com SoftwareDownloa
37. repli e sources de tension dangereuses qui pourraient provoquer des blessures graves i Ne pas utiliser l instrument ou les sondes proximit de Installation 5 Utilisation des capteurs de pression TA465 P Le TA465 P comprend des capteurs de pression qui servent mesurer les pressions statiques et diff rentielles dans les conduits Pour plus d informations voir la note d application AF 107 Capteur de pression n gatif Capteur de pression positif Connexion de la sonde de pression statique La sonde de pression statique fournie avec le mod le TA465 P est connect e au p le sur le TA465 P l aide des tuyaux fournis Cette sonde sert mesurer la pression statique des gaines et dispose d un aimant qui maintient la sonde sur les gaines 2 E q g 6 Chapitre 2 Connexion d une sonde Pitot ou sonde de d bit d air pitot rectiligne en option Quand l instrument est connect une sonde Pitot vous pouvez mesurer la vitesse de l air ou le volume d air Une sonde Pitot peut tre branch e aux capteurs de pression et sur le mod le TA465 P l aide de deux bouts de tuyau de longueur gale Le capteur de pression totale de la sonde Pitot se connecte au p le sur l instrument de mesure et le capteur de pression statique de la sonde Pitot se connecte au p le sur l instrument de mesure Si vous avez besoin d informations sur la m thode pour effectuer
38. sentes sont utilis s et entretenus normalement conform ment aux indications de ce guide d utilisation ils ne pr senteront aucun d faut de fabrication ou de composant pendant une p riode de 24 mois ou toute autre dur e applicable figurant dans le guide d utilisation compter de la date d exp dition des produits au client Cette p riode de garantie inclus toute p riode de garantie l gale Cette garantie limit e est par ailleurs formul e sous r serve des exclusions et des exceptions suivantes a Les capteurs fil chaud ou pellicule chaude utilis s avec les an mom tres de recherche de m me que certains autres composants indiqu s dans les sp cifications sont garantis pendant 90 jours compter de leur date d exp dition b Les pompes sont garanties pour le nombre d heures d utilisation indiqu dans les manuels de produit ou d utilisation c Les pi ces r par es ou remplac es dans le cadre d une proc dure de r paration appropri e sont garanties contre les d fauts de fabrication et de composants pendant 90 jours partir de la date d exp dition du mat riel r par sous r serve d une utilisation dans des conditions normales d Le vendeur n offre aucune garantie concernant les produits finis fabriqu s par d autres ni de garantie couvrant les fusibles les piles et les autres consommables Seule la garantie originale du fabricant s applique e moins d une autorisation sp cifique en ce sens dans un
39. stiques de tous les param tres de mesure stock s dans un test ID TESTO01 MIF TESTOO1 II TEST001 III Pressure Temperature RH Avg 1 739 in H2O Avg 78 2 F Avg 12 2 RH Min 1 665 in H2O0 Min 78 1 F Min 11 1 RH Max 1 812 in H20O Max 78 3 F Max 12 9 RH Samples 9 Samples 9 Samples 9 10 31 08 07 01 39 AM 10 31 08 07 01 39 AM 10 31 08 07 01 39 AM lt PRINT gt lt PRIT gt lt PRIT gt 26 Exemple TEST 001 a 9 chantillons chaque chantillon se compose d un relev de pression de temp rature et d humidit relative Utilisez les touches lt ou gt pour afficher les statistiques de chaque param tre de mesure Le TA465 peut envoyer ces donn es vers l imprimante sans fil mod le 8934 en option ou un PC compatible avec les communications Bluetooth Pour pouvoir utiliser la commande IMPRESSION il convient d tablir les communications Bluetooth entre le TA465 et l imprimante sans fil mod le 8934 ou un PC quip des communications Bluetooth Chapitre 3 Afficher chantillons VIEW DATA IIE Choose Test Test 001 View Stats View Samples Print Test Utilisez les touches fl ch es gauche et droite pour afficher les chantillons de tous les param tres de mesure stock s dans un test ID TEST001 F TEST001 III TEST001 Velocity Temperature rh Sample 1 218 ft min Sample 1 73 5 F Sample 1 15 1 rh Sample 2 280 ft min Sample 2 73 7
40. t a un Bluetooth Menu de fonctions utilis pour r gler les param tres afin de permettre des connexions sans fil avec d autres p riph riques compatibles Bluetooth MENU T Zero Press Display Setup Settings Flow Setup e etup Discover Devices Discoverability Enable RENE PINcode 0000 ee ons AutoConnects 1 Calibration Bluetooth Functions Discover Devices D marrez le processus Bluetooth de recherche d autres p riph riques du AIRFLOW meter 32 Chapitre 3 Discoverability D crit si un autre p riph rique peut d tecter l instrument de mesure AIRFLOW meter Les options incluent D sactiv L instrument n est pas d tectable par les autres p riph riques Temporary Permet l instrument d tre d tect jusqu ce qu un autre p riph rique soit associ ou jusqu ce que l instrument soit mis hors tension puis red marr Activ L instrument est toujours d tectable PINcode Le code PIN est une cl de s curit entrer dans l ordinateur lorsque celle ci est demand e Le code PIN d usine par d faut est 0000 REMARQUE Le code PIN doit tre d fini sur 0000 afin d utiliser l imprimante 8934 AutoConnects Sp cifie le nombre de tentatives de l instrument pour se reconnecter un p riph rique associ une fois mis sous tension Pour cette option le param tre D tectabilit de l instrument doit tre activ Les pa
41. ttings ENTER SETTINGS III Kfactor SelectDuct 11 Select Kfactor 1 Duet 1 0 1642 m Kfactor 1 37 Duct 2 0 03242 m Program up to 5 Kfactor 2 6 Program up to 5 Duct 3 12133m separate duct Kfactor 3 091 separate Kfactors Duct 4 2 233 m sizes Kfactor 4 11 63 Range is from Duct 5 0 1098 m Kfactor 5 17 0 001 to 999 9 lt gt z gt e S lt gt Si D bit est d fini comme la mesure Primaire dans le menu de Configuration de l affichage les dimensions ou le facteur K seront galement affich s 16 Chapitre 3 Standard Tb Standard tb mi h mh 622 43 Seem 465 whoo 1 59 m s Pt Test003 Test 003 NEXT TEST MENU STATS NEXT TEST MENU STATS Pour les mesures de d bit avec une gaine ronde une gaine rectangulaire ou une zone de la gaine la vitesse doit tre d finie comme une mesure secondaire pour que les mesures de d bit apparaissent lors de l utilisation de la sonde Pitot ou AF En cas de mesure du D bit comme la mesure Primaire les param tres peuvent tre modifi s rapidement en appuyant sur la touche A ou tandis que sur l cran de la mesure principale Duct2 MIF 3015 cm dia Select Duct KFACTOR 1 MF 32 90 Select Kfactor Effectuez les r glages avec les touches de fl che A ou V et appuyez sur lt 4 pour accepter ou acc dez au menu S lectionner une gaine ou S lectionner un facteur K pour choisir une autre valeur de d bit ou dimensi
42. vous avez besoin de plus d informations pour effectuer une travers e de conduit reportez vous la Note d application TSI 106 La touche Fact K permet de calculer le d bit des diffuseurs ou des stations de pompage l aide de prises de pression en utilisant les capteurs de pression de l instrument et les facteurs K Les facteurs K sont obtenus partir du diffuseur ou du fabricant de la station de pompage Pour plus d informations se r f rer la note d application AF 114 Jusqu a 5 gaines rectangulaires 5 gaines rondes 5 zones de gaine et 5 facteurs K peuvent tre pr programm s pour une utilisation rapide sur le lieu de travail _ ELOWSETUP t _ FLOWSETUP M ENTER SETTINGS IIP Flow Type Rowsd duet Select pre programmed Flow Type Rect ct Select Duct T Dui amas Enter ENTER SETTINGS IIP Duct dimensions Enter Settings Duct 1 20 3cm dia Select Duct T Duct 1 35 5 cm dia Duct 1 20 3 cm da Duct 2 40 8 cm dia Duct 2 35 5 cm dia Program up to 5 Duct 2 30 5 cm dia Program up to 5 Duct 3 40 6 cm dia separate duct Duct 3 30 5 cm dis separate duct Duct 4 30 5 em dia sizes Duct 3 30 5 cm dia ses Duct 5 30 5 cm dia Duct 4 20 3 cm dia Duct 4 35 5 cm dia lt gt Duct 5 40 8 cm dia lt gt lt gt Duct 5 40 6 cm dia lt gt FLOW SETUP IP how SETUE IL Flow Type Duct ses nee Select pre programmed Flow Type Prosshtact Select pre programmed Enter Settings ENTER SETTINGS IIIf Duct dimensions Enter Se
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 - ミマキエンジニアリング Mode d`emploi Lave-linge W 2819i Tripp Lite Cat5e 350MHz Molded Patch Cable (RJ45 M/M) - Blue, 10-ft. Sika Boom-S M-Joy GB Quick guide Baixar arquivo Installation manual VIP LED EN LUMIÈRE: RHL860 XL-trac Guardian COOKTOP Model Jan 2011 - Save on Security Systems, Inc. Avaya 4610SW User's Manual Copyright © All rights reserved.
Failed to retrieve file