Home
PRODIG-5
Contents
1. sis 5 14 3 TV analogique num rique Mesure du Rapport Porteuse Bruit C N 49 5 14 4 TV num rique Mesure de la Puissance 51 AxPROMAX MANUEL D UTILISATION PRODIG 5 5 14 5 TV num rique Mesure du BER sssssssssesesisrsrrsisrsinrsrnsisrnrinrnrinrnernrnsrnrnnne 52 5 14 51 Signaux DVB Ciusiiina tina ansia ad na 52 5 14 5 2 Signaux DVB T 5 14 5 3 Signaux DVB S tee 5 14 6 TV Num rique Mesure du MER 58 5 15 AnalySeur d Spectra iiicacicianiiiaiaic patenta ica cebada 60 5 15 1 Marqueurs 61 5 16 Visualisation du signal de vid o ooonnicnicninnnnnnnnoninnnanonaranonanara nan an ano nnaraarann 61 5 17 Fonction Pointage d Antennes oooconccicnncnnocnnnnnnnnnnancnnnnnn cnn n arc nar aran nnn cara an cnica nos 64 5 18 G n rateur d Instructions DiSEqC 65 5 19 Fonction SATOR essees 67 5 20 Utilisation du clavier alphanum rique 67 6 DESCRIPTION DES ENTR ES ET DES SORTIES 68 6 1 Entr e de RF iiine icono ner ee patient suns feras rA ne er ant en er ies res ibas 68 6 2 Port S rie RS 282C iain tases ctanesesnsssccdaccucdiesaisesezsadvecssceaceadssviencessceaeseitssunsas 68 6 3 Prise Scart ou P ritel DIN EN 50049 69 7 ENTRETIEN usara ce 7 1 Consid rations sur le moniteur TFT a 7 2 Recommandations de nettoyage MANUEL D UTILISATION PRODIG 5 AXxPROMAX EXPLORATEUR UNIVERSEL DE TV PRODIG 5 Digital Video Broadcas
2. 514 53 Senales DVB soisessa ne aeea aAa Eae Ek ea AEE RE EREEREER Enia 56 5 14 6 TV Digital Medida del MER 58 5 15 Analizador de Espectros sessions 59 5 15 1 Marcadores ds 5 16 Visualizaci n de la se al de video 5 17 Funci n Alinear Antenas iii 5 18 Generador de Comandos DiSEqC 5 19 Funci n SATOR irsini 5 20 Utilizaci n del teclado alfanum rico 6 DESCRIPCI N DE ENTRADAS Y SALIDAS eee 69 6 1 Entrada de AP aici soscionicaconcinnicincan condon ttnan 69 6 2 Puerto Serie RS 232C 69 6 3 Euroconector DIN EN 50049 issus 70 7 MANTENIMIENTO 5c circos coa ill il dc 71 7 1 Consideraciones sobre el monitor TFT da 7 2 Recomendaciones de Limpieza ss 71 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX EXPLORADOR DE TV UNIVERSAL PRODIG 5 DV3 Digital Video Broadcasting 1 GENERALIDADES 1 1 Descripci n El explorador de televisi n PRODIG 5 EXPLORER representa un paso evolutivo respecto a los medidores de campo tradicionales PROMAX continua innovando en el sector de los medidores de campo presentando un equipo que cambia la forma de hacer y entender las medidas de las se ales de televisi n Este equipo incorpora importantes avances tanto en los aspectos funcionales como en la ergonom a para permitir a los instaladores realizar su trabajo con la m xima comodidad y rapidez A la vez el instrumento resulta fiable ante cualquier posible problema de la se al de entrada en los compon
3. 5 10 Fonction Datalogger Saisies La fonction Datalogger permet de r aliser et d emmagasiner mesures de mani re totalement automatique Elle peut stocker pour chaque saisie des mesures effectu es dans diff rents points de installation Les mesures sont r alis es sur les param tres enregistr s pour tous les canaux pr sents dans le plan de canaux actif tant pour canaux analogiques comme num riques 8 Pour choisir la fonction Datalogger activer le menu d OUTILS 5 22 et choisir l option FAIRE SAISIES Ensuite en tournant la mollette 1 choisir une acquisition pr alablement stock e ou bien une NOUVELLE SAISIE Page 34 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX 13 41 POINT DE MESURE PLAN FREQUENCES FREQ MHz CAN Dans le cas de canaux num riques et puisque ceux ci impliquent un plus grand processus de calcul dans la partie inf rieure de l cran il apparait un compteur du temps qu il reste pour finir toutes les mesures dans ce canal Dans le coin sup rieur de l cran on indique le canal qui est en train de mesurer du total correspondant au plan de canaux Pour acc der aux diff rents champs de l cran on doit pousser les touches de A lt gt curseur y 6 et sion souhaite les diter il faut pousser encore la mollette 1 Apr s avoir activ le champ COMMENCER l appareil proc dera de mani re automatique la r alisation des mesures Quand l appareil a fini le processus
4. ada El Mh A ABC g DEF g GHI 0 KE pise amp A ex MNO PARS TUV WXYZ 4 35554 Figure 4 Main keyboard a D b _e TV KEY It allows visualising the image of TV corresponding to the input signal as well as data relative to the reception of the video signal Key number 1 to enter numeric data yf y 2 al D 2 asc EXTERNAL UNITS POWER SUPPLY Enables selecting the power supply to the external units Available voltages are External 5 V 13 V 15 V 18 V and 24 V for the terrestrial band and External 5 V 13 V 15 V 18 V 13 V 22 kHz and 18 V 22 kHz for the satellite band Key number 2 to enter numeric data 3 ver MEASUREMENTS Enables the type of measurement to be selected The types of measurements available depend on the band the standard and the operating mode Key number 3 to enter numeric data 11 2013 Page 21 13 14 15 16 17 18 19 20 AXPROMAX USER S MANUAL PRODIG 5 eH SPECTRUM TV Allows switching between any previous operating mode and the Spectrum Analyser mode and viceversa Key number 4 to enter numeric data 5 Ss AT sk SATELLITE TERRESTRIAL BAND Allows switching between the Satellite or Terrestrial TV frequency band Key number 5 to enter numeric data S This led remains lighted when the equipment works with the frequencies and the corresponding channels to the
5. 25 hasta que aparezca la pantalla del EXPLORADOR EXPLORADOR ANALI ZANDO CANALI ZACI ON PROMAX 0 25 50 75 100 66 DVB T OK 67 NOIDENTIFICADO 68 ANALOGICO PAL BG 69 SIN SE AL ENCONTRADOS 12 101 EXPLORACI N FINALIZADA METE GUARDAR PROMAX 01 Figura 17 Pantalla de exploraci n del espectro EXPLORER 11 2013 P gina 39 AXxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Siempre que el proceso detecte nuevos par metros para alg n canal crear una nueva lista de canales conteniendo la informaci n detectada NOTA En el caso que se desee explorar se ales DVB C es necesario acceder 8 previamente al men de PREFERENCIAS x 22 y seleccionar como Identificador de se ales digitales terrestres el est ndar DVB C 5 13 Configuraci n de las Medidas Con el fin de realizar las medidas de algunos tipos de se ales puede ser necesario que el usuario introduzca algunos par metros relativos a las caracter sticas particulares de estas se ales cuando no haya sido posible la detecci n autom tica o stas difieran de las correspondientes al est ndar _ D Pulsar la tecla de configuraci n de medidas 17 para acceder al menu de CONFIGURACI N y girar el selector rotativo 1 para acceder a los par metros relativos a la se al modificables por el usuario 5 13 1 Configuraci n de un Canal Digital DVB C QAM D Pulsar la tecla de configuraci n de medidas e 17 para acceder al men de CONFIGURACI N
6. 5 6 7 8 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Para activar la puesta en marcha del equipo mantener pulsado el selector durante m s de dos segundos hasta que aparezca la pantalla de presentaci n Para apagar el medidor mantener pulsado el selector hasta que se desconecte la alimentaci n Para modificar la sinton a al girarlo en el sentido de las agujas del reloj la frecuencia aumenta mientras que al girarlo en sentido contrario a las agujas del reloj disminuye Para desplazarse sobre los men s de funciones al girarlo en el sentido de las agujas del reloj el cursor se desplaza hacia abajo mientras que al girarlo en sentido contrario a las agujas del reloj sta se desplaza hacia arriba EXT VIDEO Indicador luminoso de presencia de se al de v deo exterior Se ilumina cuando el v deo que se presenta en la pantalla procede del Euroconector 35 DRAIN Indicador luminoso de alimentaci n de unidades externas Se ilumina cuando se suministra corriente a la unidad externa desde el PRODIG 5 EXPLORER CHARGER Indicador luminoso de alimentaci n mediante alimentador DC externo Cuando las bater as est n instaladas el alimentador de bater as se activa autom ticamente SENSOR Sensor de luminosidad ambiental permite el ajuste autom tico del contraste y brillo de la pantalla contribuyendo al ahorro de la bater a A y CURSORES Permiten el ajuste en el modo Analizador de Espectros del nivel de referenc
7. 3 4 Porteuses Nombre de porteuses Le param tre Porteuses d finit le nombre de porteuses de la modulation soit 2k ou 8k Pour modifier sa valeur en tournant la mollette placez le curseur sur le champ Porteuses et puis la poussez En tournant la mollette 1 choisissez la valeur souhait e et finalement la poussez nouveau pour la valider Garde Intervalle Garde Le param tre correspond au temps mort entre les symboles son but est de permettre une d tection correcte dans des situations d cho par trajets multiples Ce param tre est d fini selon la longueur de symbole 1 4 1 8 1 16 1 32 Pour modifier sa valeur en tournant la mollette 1 placez le curseur sur le champ Garde et puis la poussez En tournant la mollette 1 choisissez la valeur souhait e et finalement la poussez nouveau pour la valider Largeur Canal Largeur de bande de canal Cette option permet de s lectionner la largeur de bande des canaux entre 8 MHz 7 MHz et 6 MHz La s lection de ce param tre est indispensable pour que le syntoniseur fonctionne correctement du fait qu il affecte la s paration en fr quence des porteuses Inv Spectrale Inversion spectrale Cette option permet d appliquer une inversion spectrale au signal d entr e bien que dans la majorit des cas elle doive tre en NON non inversion Ce menu de configuration montre en plus des param tres du signal COFDM s lectionnables par l utilisateur les valeurs des pa
8. 6 1 RF input The RF input is through the RF 30 connector on the side panel The peak signal level should never exceed 130 dBuV 6 2 RS 232C serial port The PRODIG 5 EXPLORER incorporates an RS 232C serial port to communicate with a PC through the Pktools or NetUpdate software and to perform diagnosis setup and calibration processes The signals in this connector are described in Table 4 nN o BU E Figure 42 RS 232C connector External view PIN No SIGNAL CHARACTERISTICS 1 Carrier detect not connected 2 Data Receive RxD 3 Data Transmit TxD 4 Data Terminal Ready DTR not connected 5 Ground GND 6 Data Set Ready DSR not connected 7 Request to Send RTS 8 Clear to Send CTS 9 Ring Indicator not connected Table 4 Description of the RS 232C connector 11 2013 Page 67 ZXPROMAX USER S MANUAL PRODIG 5 6 3 Scart DIN EN 50049 201816141210 8 6 4 2 e Adhd dah ddl ddd PAPE UP eye yp A 2119171513119 7 5 3 1 Figure 43 Scart socket external view Also known as PERITEL connector in conformity with standard NF C92250 The signals in this connector are the following PIN number SIGNAL CHARACTERISTICS 1 Right channel audio output 2 Right channel audio input 3 Left channel audio output 4 Audio grounding 5 Blue ground
9. 9 wxyz APUNTAMIENTO DE ANTENAS Utilidad para alinear antenas en banda sat lite y terrestre de barrido m s r pido con presentaci n de medidas sobre una barra gr fica de nivel Tecla n mero 9 para la entrada de datos num ricos 0 SINTON A CANAL FRECUENCIA Conmuta el modo de sinton a entre canal o frecuencia En modo canal la selecci n de la frecuencia de sinton a se ajusta a la tabla de canales activa CCIR Tecla n mero 0 para la entrada de datos num ricos IDENTIFICACI N AUTOM TICA EXPLORACI N Activa la funci n de identificaci n autom tica pulsaci n corta El equipo intentar identificar la se al presente en el canal Primero averigua si se trata de un canal anal gico o digital Si el canal es anal gico determina el tipo de est ndar de la se al detectada Si es digital analiza para cada tipo de modulaci n QAM QPSK COFDM todos los par metros asociados portadoras 2k 8k symbol rate code rate etc y determina los valores de la se al bajo prueba En modo analizador de espectro indica en la pantalla el nombre de la red y la posici n orbital s lo en banda sat lite Activa la funci n de exploraci n de la banda pulsaci n larga El medidor explora toda la banda de frecuencias para identificar los canales anal gicos y digitales presentes 11 2013 P gina 25 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 80 Figura 5 Vista panel superior 30 RF En
10. S MANUAL PRODIG 5 The symbol X in the upper corner of the screen indicates that the equipment is saving information to the internal memory This symbol appears whenever the user selects a data storage option when pressing the rotary selector 1 5 10 Acquisition function DATALOGGER The Datalogger function allows the user to carry out and store measurements in a fully automatic way lt can store for each acquisition the measurements made in different points of the installation The measurements made are relevant to the current analogue or digital channel in the active channel plan 8 To select the Datalogger function activate the UTILITIES rov 22 menu and select the RUN DATALOGGER option Later by turning the rotary selector 1 select a previously stored acquisition or a NEW DATALOGGER 14 41 TEST POINT CHANNEL SET FREC Figure 11 DATALOGGER screen In the case of digital channels which require a greater calculation process a timer counter will appear in the lower part of the screen In the upper corner the channel number being measured will appear followed by the total number of channels in the current channel plan A lt gt In order to select the different fields on the screen press the cursor keys 6 and then edit by pressing the rotary selector 1 Page 34 11 2013 After selecting the START field the instrument begins to carry out the available measurements automatically Once comple
11. syntonie par canal et vice versa Dans le mode syntonie par canal en tournant la mollette 1 on pourra syntoniseur s quentiellement les canaux d finis dans le plan de canaux actif En tournant la mollette dans le sens des aiguilles d une montre la fr quence augmente alors qu en la tournant dans le sens contraire la fr quence diminue Dans le mode syntonie par fr quence il existe deux m thodes de syntonie 1 En tournant la mollette 1 En agissant sur la mollette 1 on pourra s lectionner la fr quence souhait e la syntonie est continue de 45 865MHz et de 950 2150 MHz En tournant la mollette dans le sens des aiguilles d une montre la fr quence augmente alors qu en la tournant dans le sens contraire la fr quence diminue 11 2013 Page 29 LR PROMAX MANUEL D UTILISATION PRODIG 5 2 Introduction l aide du clavier Pousser la mollette 1 l indication de fr quence dispara tra et appara tra dans la partie sup rieure gauche de l cran le symbole d entr e de donn es manuellement 123 ensuite l aide du clavier num rique introduire la valeur de la fr quence souhait e en MHz Le PRODIG 5 EXPLORER calculera la fr quence pouvant tre synth tis e la plus proche de la valeur introduite et la pr sentera l cran 5 5 Recherche Automatique d metteurs En poussant la touche 21 on effectuera une course jusqu ce qu on trouve un metteur ayant un niveau de signal sup r
12. 230 kHz Banda terrestre 4 MHz Banda sat lite Rizado en banda 1 dB m ximo Sonido TONO Tono que var a con el nivel de se al S lo en modo de apuntamiento de antenas P gina 5 AxPROMAX Precisi n Banda terrestre Banda sat lite Indicaci n de sobremargen MODO MEDIDAS Bandas terrestres Canales anal gicos Canales digitales Banda sat lite Canales anal gicos Canales digitales Funci n ADQUISICI N Canales anal gicos Canales digitales Funci n PRUEBA ICT Funci n TEST ATENUACI N MANUAL DE INSTRUCCIONES PRODIG 5 1 5 dB 30 120 dBuV 45 865 MHz 22 C 5 C 2 5 dB 40 100 dBuV 950 2050 MHz 22 C 5 C ty Nivel Relaci n V deo Audio y Relaci n Portadora Ruido Potencia del Canal Relaci n Portadora Ruido e Identificaci n del canal Nivel y Relaci n Portadora Ruido Potencia del Canal y Relaci n Portadora Ruido Adquisici n y registro autom tico de medidas Nivel C N y V A Offset de frecuencia detecci n MPEG 2 potencia C N MER CBER VBER y margen de ruido Respuesta para redes de distribuci n Fl en banda sat lite Respuesta para redes de distribuci n de se ales en banda terrestre MODO ANALIZADOR DE ESPECTROS Banda sat lite Bandas terrestres Ancho de banda de medida Terrestre Sat lite Span Terrestre Sat lite Marcadores Medidas Bandas terrestres Canales anal gicos Canales digitales 30 dBuV a 120 dByV 31 6 pV a 1 V
13. MHz M REF kHz M LEVEL SET sae EST Figure 14 End of data acquisition NOTE In order to select the function Attenuation test or IF SAT test might be necessary to switch the frequency band between Terrestrial or Satellite by AN means of the front panel x key 10 Page 36 11 2013 5 11 Verification of distribution networks SAT IF Test Attenuation Test This application allows to verify easily the TCI features Telecommunications Common Infrastructures before the antennas and head end devices are operative The procedure allows to evaluate the frequency response of a whole TV signals distribution network by means of two steps NOTE For this application the use of PROMAX s RP 050 RP 080 or RP 250 signal generators are required for which they have been specially designed 1 CALIBRATION Connect the generator directly to the PRODIG 5 EXPLORER using the BNC F adapter Power on the RP 050 RP 080 through the EXPLORER for it is necessary to set the External supply function see section 5 7 External Units Power Supply pressing key 11 and the rotary selector 1 for setting a voltage of 13 V Finally select the SAT IF TEST application on UTILITIES rov 22 menu for SAT band or the ATTENUATION TEST for terrestrial band connect the generator to the point where antenna will be connected signal source and by means of the horizontal cursors 6 select the Calibrate function see follow
14. PRODIG 5 5 8 Funci n de Identificaci n Autom tica de se ales AUTO ID El PRODIG 5 EXPLORER permite identificar autom ticamente se ales de TV conforme a la configuraci n establecida que se encuentren presentes en el canal o frecuencia sintonizada Para activar esta funci n debe presionar una vez sobre la tecla o 25 Especialmente til puede resultar combinar este proceso con la 4 monitorizaci n del espectro ti 13 de forma que tras situar el marcador sobre los niveles susceptibles de contener una emisi n y activando a continuaci n el proceso de identificaci n autom tica permita identificar la se al existente Lal FREC 794 00 MHz CANAL 61 INICIANDO PRUEBA ANALOGI CA NIVEL INSUFICIENTE 43 6 lt 50 0 dBuV PROBANDO DVB T POTENCIA OK 60 0 gt 32 0 dBuV ESTIMANDO ANCHO DE BANDA Figura 9 Pantalla de identificaci n autom tica de se ales AUTO ID El equipo en cada caso trata de averiguar si se trata de un canal anal gico o digital Si el canal es anal gico determina el tipo de est ndar de la se al detectada Si es digital DVB analiza para cada tipo de modulaci n QAM QPSK COFDM todos los par metros asociados portadoras 2k 8k symbol rate code rate etc y determina los valores de la se al bajo prueba Si la funci n de identificaci n se activa en el modo analizador de espectro el nombre de la red aparecer en la pantalla este dato se indica en la pantalla del modo d
15. Para visualizar la se al de v deo 5 IS T 1 Seleccionar la banda de frecuencias terrestre sx 14 0 LL 2 Sintonizar el canal o frecuencia 24 que se desee visualizar en pantalla 3 SS 3 Comprobar que el equipo recibe un nivel de se al apropiado oer 12 1 4 Pulsar 10 para visualizar la imagen de TV si el canal es digital pulsar Ww 6 y situar el cursor sobre el campo Identificador de Servicio presionar el selector rotativo 1 para obtener la lista de los servicios disponibles 11 2013 P gina 17 ZXPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Pagina 18 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX 5 INSTRUCCIONES DE UTILIZACI N ADVERTENCIA Las funciones que se describen a continuaci n podr an ser modificadas en funci n de actualizaciones del software del equipo realizadas con posterioridad a su fabricaci n y a la publicaci n de este manual 5 1 Descripci n de los Mandos y Elementos Panel frontal 3 leds ABC e y 8 9 0 CE osc ZA ca o MNO PQ TUV WXYZ A RS PRODIG 5 UNIVERSAL TV EXPLORER Figura 3 Panel frontal 1 Selector rotativo y pulsador Posee m ltiples funciones Puesta en marcha y apagado del equipo control de sinton a desplazamiento por los diferentes men s y submen s que aparecen en el monitor y validaci n de las distintas opciones 11 2013 P gina 19 2 3 4
16. Prise p ritel N DE PIN SIGNAL CARACT RISTIQUES 1 Sortie audio canal droit 2 Entr e audio canal droit 3 Sortie audio canal gauche 4 Masse audio 5 Masse bleu B 6 Entr e audio canal gauche 7 Sortie signal bleue B 8 Tension de commutation 9 Masse verte G 10 Ligne d interconnexion des donn s 2 not branch 11 Sortie signal vert G 12 Ligne d interconnexion des donn s 1 not branch 13 Masse rouge R 14 Masse commune des lignes d interconnexion des donn s not branch 15 Sortie signal rouge R 16 Signal ffacement not branch 17 Masse vid o compos 18 Retour effacement not branch 19 Sortie vid o compos 20 Entr e vid o 21 Masse blindage connecteur Tableau 5 Description de la prise P ritel Pour choisir le mode de fonctionnement du connecteur SCART entre Entr e de vid o Sortie de vid o ou Automatique depuis le mode de visualisation de TV 10 suivre les pas suivants 1 Choisir le menu de Configuration des Mesures en poussant la touche D 17 et v rifier que le type de signal est ANALOGIQUE 2 Choisir le mode ad quate de fonctionnement du SCART avec l option Vid o Audio Ext de ce menu 11 2013 Page 69 AxPROMAX MANUEL D UTILISATION PRODIG 5 7 ENTRETIEN A 7 1 Consid rations sur le moniteur TFT ll faut savoir qu il existent des contraintes dans la fabrication des crans TFT Par la suite veuillez trouver les sp cifications fournies par leur
17. ales DVB T COFDM como DVB S QPSK y DVB C QAM 1 BAXS Trade Mark of the DVB Digital Video Broadcasting Project 4026 11 2013 Pagina 1 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Al ser un equipo multiest ndar puede ser utilizado eficientemente en cualquier pa s del mundo Incorpora un teclado iconogr fico que permite el acceso directo a las funciones que aparecen en la pantalla de una forma intuitiva El PRODIG 5 realiza una exploraci n din mica del espectro detectando todas las emisiones que se encuentran en la banda explorada ya sea terrestre o sat lite El propio equipo es el que localiza los canales y los colecciona en una base de datos sin necesidad de ninguna informaci n previa sobre el n mero de canales el tipo de se ales transmitidas o las caracter sticas de las mismas Con los datos adquiridos tras cada exploraci n crea un registro que contiene tablas de canales independientes para cada sistema o instalaci n En cualquier momento se pueden repetir las sesiones de medida utilizando solamente estos canales presintonizados Permitiendo as agilizar el proceso En el panel frontal aparece indicado el tipo de medida que se realiza Terrestre Sat lite Anal gico Digital y los datos son visualizados mediante una pantalla gr fica TFT de 5 de alta resoluci n El equipo incorpora un sensor para el ajuste autom tico del contraste y la luminosidad de la pantalla de acuerdo con las condiciones ambient
18. en test 1 BAXS Trade Mark of the DVB Digital Video Broadcasting Project 4026 11 2013 Page 1 AxPROMAX MANUEL D UTILISATION PRODIG 5 Le PRODIG 5 comprend les principaux standards de t l vision M N B G I D K et L et adapte en plus des param tres propres du standard le syst me automatique de correction pour obtenir dans tous les cas une mesure pr cise du niveau de signal d entr e ll accepte tous les syst mes de t l vision PAL SECAM et NTSC et permet de travailler directement avec des signaux de t l vision num rique en les d codant pour visualiser l image de t l vision et pour lesquels il fournit directement la mesure de la puissance du rapport de porteuse a bruit C N du taux d erreur du signal num rique BER et du rapport d erreur de modulation MER m me pour signaux DVB T COFDM comme DVB S QPSK et DVB C QAM Du fait qu il s agit d un appareil multi standard il peut tre utilis de mani re efficace dans n importe quel pays du monde Il incorpore un clavier iconographique pour l acc s direct aux fonctions qui apparaissent dans l cran de mani re intuitive Le PRODIG 5 effectue une exploration dynamique de l espectre en d tectant toutes les missions qui se trouvent dans la bande explor e bien terrestre que satellite L appareil est qui localise lui m me les canaux et les collectionne dans un registre de donn es sans avoir besoin d aucune information pr alable sur
19. ndar DVB T DVB C DVB S y MPEG 50 us S ntesis digital de frecuencia autom tica seg n est ndar de TV Para operaciones de mantenimiento y calibraci n Por el conector de entrada RF Externa 5 13 15 18 24 V Seleccionable en banda sat lite 06V 0 2V 22 kHz 4 kHz 5W De acuerdo con el est ndar DiSEqC 1 2 Bater a Li lon de 7 2 V 11 Ah Superior a 3 5 horas en modo continuo E DisEgc TM es una marca registrada de EUTELSAT 11 2013 P gina 7 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Tiempo de carga 3 horas al 80 con el equipo apagado Externa Tensi n 12V Consumo 35 W Desconexi n autom tica Programable Transcurridos los minutos seleccionados sin actuar sobre ning n mando Desactivable CONDICIONES AMBIENTALES DE FUNCIONAMIENTO Altitud Hasta 2000 m Margen de temperaturas De 5 a 40 C Desconexi n autom tica por exceso de temperatura Humedad relativa m xima 80 Hasta 31 C decreciendo linealmente hasta el 50 a 40 C CARACTER STICAS MEC NICAS Dimensiones 230 A x 161 Al x 76 Pr mm Volumen total 2 814 cm Peso 1 9 kg sin protector antichoque ACCESORIOS INCLUIDOS 1x CB 077 Bater a recargable Li 7 2 V 11 Ah 1x AT 010 Atenuador 10 dB 1x AD 055 Adaptador F H BNC H 1x AD 056 Adaptador F H DIN H 1x AD 057 Adaptador F H F H 1x AL 103 Alimentador DC externo 1x DC 265 Funda de protecci n 1x DC 289 Cinta de transporte 1x AA 103 Cable alim
20. riques par exemple une fr quence de canal Pousser la touche correspondant au digit qu on souhaite introduire de 0 a D 9 En poussant la touche du point d cimal 17 on introduit le caract re point et ensuite l appareil permet encore d introduire deux digits Pour 0 introduire un num ro n gatif on doit pousser d abord la touche 24 jusqu a ce qu apparaisse le signe Pour effacer un digit on doit se d placer avec les touches des fl ches horizontales de curseur 6 en pla ant le curseur derri re le digit qu on go souhaite effacer et ensuite maintenir pouss e la touche 17 jusqu ce que disparaisse le digit R p ter l op ration par chaque digit additionnel qu il souhaite liminer Introduction de donn es alphanum riques par exemple le nom d un plan de canaux Pousser la touche du clavier 8 correspondant la lettre ou le digit qu on souhaite introduire On peut crire le mot qui est souhait en poussant la touche o on trouve la lettre qui on besoin On devra pousser cette touche avant que passent les deux seconds et le num ro de fois qu il soit n cessaire jusqu ce qu apparaisse la lettre ou le digit souhait l cran Pour passer de lettres minuscules des majuscules et vice versa pousser d abord la touche lt 25 SAL Pousser la touche de curseur fleche sup rieure 6 pour annuler une entr e de donn es par le clavier 11 2013 En main
21. service identifier SID network name network identifier NID video program identifier VPID audio program identifier APID video bit rate VIDEO audio bit rate AUDIO and type of coding MPEG 1 MPEG 2 or AC 3 A lt gt When pressing the cursor arrow _ 6 will appear the tuning information window again in order to fix on screen this window the vertical cursors 6 must be pressed up to select the OSD OFF field so press rotary selector 1 to switch to OSD ON If the transmission is not codified on the lower right corner a FREE indication is showed or otherwise states COD Also the standard MPEG 2 profile is indicated which determines the compression rate for the digital service decodified the level of image resolution 4 3 the resolution rows x columns for received video and the picture refreshment frequency rate In the OSD OFF mode the information window previously described will appear whenever the rotary selector is pressed again 1 Figure 37 Analogue channel monitoring The symbol X in the upper corner of the screen indicates that the instrument has detected a saturation condition for analogue signals in the currently channel tuned This symbol also appears when the colour subcarrier signal Burst does not contain information and therefore the images are shown in black and white Page 62 11 2013 USER S MANUAL PRODIG 5 AXPROMAX When a digital channel is decodified once the Ta
22. x Follow the cleaning instructions described in the Maintenance paragraph 11 2013 Page 9 AXPROMAX USER S MANUAL PRODIG 5 X Symbols related with safety DIRECT CURRENT ALTERNATING CURRENT DIRECT AND ALTERNATING GROUND TERMINAL PROTECTIVE CONDUCTOR FRAME TERMINAL EQUIPOTENTIALITY ON Supply OFF Supply DOUBLE INSULATION Class II Protection CAUTION Risk of electric shock CAUTION REFER TO MANUAL l gt eB oO Gg Orde FUSE Page 10 11 2013 2 2 Descriptive Examples of Over Voltage Categories Cat Low voltage installations isolated from the mains Cat Il Portable domestic installations Cat Ill Fixed domestic installations Cat IV Industrial installations 11 2013 page ZXPROMAX USER S MANUAL PRODIG 5 Page 12 11 2013 3 INSTALLATION 3 1 Power Supply The PRODIG 5 EXPLORER is a portable instrument powered by one 7 2 V 11 Ah Li lon battery There is also an external DC charger provided for mains connection and battery charging 3 1 1 Operation using the External DC Charger Connect the external DC charger to EXT SUPPLY 32 on the PRODIG 5 EXPLORER side panel Connect the DC charger to the mains Then press the rotary selector 1 for more than two seconds The level meter is now in operation and the battery is slowly charged When the instrument is connected to the mains the CHARGER indicator 4 remains lit This indicator changes of colour according to the batter
23. y verificar que el tipo de sefial es ANALOGICA 2 Seleccionar el modo adecuado de funcionamiento del SCART mediante la opci n Vid Aud Ext de este men P gina 70 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX 7 MANTENIMIENTO A 7 1 Consideraciones sobre el monitor TFT A continuaci n se exponen consideraciones importantes sobre el uso del monitor color extra das de las especificaciones del fabricante En la pantalla TFT pueden aparecer p xeles que no se iluminan o que se iluminan de forma permanente y no por ello se debe considerar que exista un defecto de fabricaci n del mismo De acuerdo con el est ndar de calidad del fabricante se considera admisible un m ximo de 9 p xeles de estas caracter sticas Tampoco se considerar n defectos de fabricaci n aquellos que no se detecten a una distancia entre la superficie de la pantalla TFT y el ojo humano mayor de 35 cm con una visualizaci n perpendicular entre el ojo y la pantalla Por otra parte se recomienda para obtener una visualizaci n ptima de la pantalla un ngulo de visualizaci n de 15 respecto de la perpendicular del monitor 7 2 Recomendaciones de Limpieza PRECAUCI N Para limpiar la caja asegurarse de que el equipo est desconectado PRECAUCI N No se use para la limpieza hidrocarburos arom ticos o disolventes clorados Estos productos pueden atacar a los materiales utilizados en la construcci n de la caja La caja se limpiar con una l
24. 10 dBuV a 120 dBuV 3 16 pV a 1 V 230 kHz 4 MHz Full span banda completa 500 200 100 50 32 16 8 MHz seleccionable Full span banda completa 500 200 100 50 32 16 MHz seleccionable 1 con indicaci n de frecuencia y nivel Nivel Potencia del Canal 3 Mediante la aplicaci n de software PkTools para uso con ordenador personal Funci n para uso con el simulador de Fl RP 050 RP 250 5 Funci n para uso con el generador de se ales RP 080 RP 250 P gina 6 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 Banda sat lite Canales anal gicos Canales digitales PRESENTACI N EN MONITOR Monitor Sistema de color Est ndares de TV Funci n de espectro Sensibilidad SE AL EN BANDA BASE V DEO Entrada v deo externo Sensibilidad Salida de v deo SONIDO Entrada Salidas Demodulaci n De nfasis Subportadora INTERFAZ RS 232C ALIMENTACI N DE LAS UNIDADES EXTERIORES Terrestre y sat lite Se al de 22 kHz Tensi n Frecuencia Potencia m xima GENERADOR DiSEqC ALIMENTACION Interna Bateria Autonomia AXPROMAX Nivel Potencia del canal TFT color 5 pulgadas PAL SECAM y NTSC M N B G 1 D KyL Span margen din mico y nivel de referencia variables mediante cursores 40 dBuV para sincronismo correcto Euroconector 1 Vpp 75 Q v deo positivo Euroconector 75 Q Euroconector Altavoz incorporado Euroconector Sistemas PAL SECAM NTSC seg n est
25. 14 5 Digital TV Measuring BER The PRODIG 5 EXPLORER offers three ways to measure the error rate BER of digital signals depending on the type of used modulation To select the BER measurement mode gt 1 Select digital signals Measurements Configuration pressing 17 key 2 Select by means of Signal option from CONFIGURATION menu DVB C for the measurement of QAM modulated signals DVB T for the measurement of COFDM modulated signals or DVB S for the measurement of QPSK modulated signals Available frequency ranges are DVB C QAM signals 45 MHz to 865 MHz DVB T COFDM signals 45 MHz to 865 MHz DVB S QPSK signals 950 MHz to 2150 MHz 11 2013 Page 51 ZXPROMAX USER S MANUAL PRODIG 5 3 Enter the parameters relative to the digital signal which appear in the measurement CONFIGURATION menu as described previously 4 Select the option to exit from measurements CONFIGURATION menu 5 14 5 1 DVB C signals Once determined the parameters of QAM signal it will be possible to measure BER press the s 12 key until the BER measurement display appears In the BER measurement mode the monitor will show a display like the following one DVB C QAM 3 4E 4 Figure 26 Screen of BER measurement of QAM signals The BER measurement before error correction is shown BER before FEC Forward Error Correction In a digital reception system for cable signals after the QAM demodulator an error correction method
26. 44 11 2013 C N Out channel measurement Noise level is measured at frojge funing Channel BW To measure it correctly digital channel must be tuned at its central frequency MER Modulation error ratio CBER BER measurement Bit error rate for the digital signal before error correction BER before FEC VBER BER measurement Bit error rate for the digital signal after error correction BER after Viterbi Satellite band Analogue channels Level Level measurement of the currently tuned carrier C N Ratio between the modulated signal power and the equivalent noise power for a same bandwidth Satellite band Digital channels DVB S Channel Power Automatic method C N Ratio between the modulated signal power and the equivalent noise power for a same bandwidth MER Modulation error ratio CBER BER measurement Bit error rate for the digital signal before error correction BER before FEC VBER BER measurement Bit error rate for the digital signal after error correction BER after Viterbi 3 In order to change the measurement mode press 5 12 key On the monitor will appear cyclically all the measures available for the tuned signal 5 14 1 Analogue TV Measuring the Video Carrier Level In the measurement mode of analogue signals the PRODIG 5 EXPLORER monitor can work as an analogue indicator of level representing the signal present in the input 11 2013 Page 45 ZXPROMAX USER S MANUAL PRODIG
27. 5 3 In order to change the measurement mode press ce 12 key it will appear a screen like the following one TERRESTRIAL LEVEL 78 2 dBuV 70 90 MHz M LEVEL C N V A Figure 21 Analogue signal level measurement in terrestrial band Turn the rotary selector 1 to change the tuning channel frequency Press the ver 12 key to select the type of measurement to visualise on the monitor The available types of measurements are LEVEL Level indication on the upper part of the screen analogue bar CIN Carrier Noise ratio measurement VIA Video Audio ratio measurement Page 46 11 2013 WARNING When at the RF input appear an important number of carriers with a high level the tuning circuit may become out of control giving as a result wrong level measurements To be able to determinate the equivalent level of a carrier group with similar levels at the RF input it is possible to use the expression L L 10 log N Lg equivalent total level L average level of the carriers group N number of carriers So if there are ten carriers with a level around 90 dBuV their equivalent level will be 90 dBuV 10 log 10 100 dBuV Observe that in this case loss of tuning by overload of the RF input may occur besides other effects such as tuner saturation and generation of intermodulation products that may mask the spectrum visualization 5 14 2 Analogue TV Measuring the Video Audio ratio V A
28. INSTRUCCIONES PRODIG 5 AXxPROMAX FI NALI ZADO PUNTO DE MEDI DA CANALI ZACI ON MHz M REF kHz NIVEL Figura 14 Finalizaci n de la adquisici n NOTA Para seleccionar las funciones Test de Atenuaci n o prueba FI SAT ICT puede ser necesario conmutar previamente entre Ja banda de Ss frecuencias de TV Sat lite o TV Terrestre mediante la tecla ix 10 del panel frontal 5 11 Comprobaci n de redes de distribuci n Prueba FI SAT ICT Test Atenuaci n Esta aplicaci n permite comprobar de forma sencilla la respuesta de las instalaciones de ICT Infraestructuras Comunes de Telecomunicaciones antes de que est n operativas las antenas y los dispositivos de cabecera El procedimiento permite evaluar la respuesta frecuencial de toda una red de distribuci n de se ales de TV a partir de dos sencillos pasos NOTA Para esta aplicaci n se recomienda la utilizaci n de los generadores de se ales RP 050 y RP 080 o RP 250 de PROMAX para los cuales ha sido especialmente dise ada 1 CALIBRACI N Conectar directamente el generador al PRODIG 5 EXPLORER mediante el conector adaptador BNC F 11 2013 P gina 37 AXxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Alimentar el RP 050 RP 080 a trav s del EXPLORER para ello seleccionar la funci n Alimentaci n de las unidades exteriores ver apartado 5 7 Alimentaci n de 2 las Unidades Exteriores pulsando la tecla a 11 y mediante el selector rotativ
29. In order to power on the equipment hold the rotary selector pressed for more than two seconds until the presentation screen appears 11 2013 Page 19 2 3 4 5 6 7 8 AXPROMAX USER S MANUAL PRODIG 5 In order to power off the meter hold the rotary selector pressed Tuning purposes turning it clockwise frequency increases while turning it anticlockwise frequency decreases To move along the on screen menus turning it clockwise active option moves downwards while turning it anticlockwise active option moves upwards EXT VIDEO Video signal presence light indicator It lights up when video on screen is coming through the SCART connector 35 DRAIN External units power supply indicator Lights up when the PRODIG 5 EXPLORER supplies a current to the external unit CHARGER External DC charger operation indicator When batteries are installed the battery charger is automatically activated SENSOR Sensor of environmental luminosity allows automatic adjusts of the display contrast and brightness contributing to the battery saving A y CURSORS Allow adjust in the Spectrum Analyser mode of the reference level and the margin of frequencies to represent span As well as the movement through the different menus and submenus that appear in the monitor MONITOR MAIN KEYBOARD 12 keys to select functions and entering alphanumeric data Page 20 11 2013 10 11 12 48 to 49 9
30. In the Audio Video measurement mode on the screen appears the following information TERRESTRIAL 16 2 dB 30 40 LEVEL C N VA Figure 22 Measurement of the video audio rate 11 2013 Page 47 AXPROMAX USER S MANUAL PRODIG 5 In addition to the video carrier audio carrier level ratio 16 2 dB in previous figure it also shows the frequency or channel depending on the tuning mode selected and the Carrier Noise ratio 5 14 3 Analogue Digital TV Measuring the Carrier Noise ratio C N The PRODIG 5 EXPLORER carries out C N ratio measurement in four different ways according to the carrier type and the used band A B C D Terrestrial band analogue carrier Carrier level is measured using a quasi peak detector 230 kHz BW Noise level is measured with an average detector and corrected to refer it to channel equivalent noise bandwidth according to the definition of the selected standard Terrestrial band digital carrier Both measurements are done with an average detector 230 kHz and the same corrections are introduced on them bandwidth corrections Satellite band analogue carrier Carrier level is measured using a quasi peak detector 4 MHz BW Noise level is measured with an average detector 230 kHz and corrected to refer it to channel bandwidth Satellite band digital carrier Equivalent to case B but now using the 4 MHz BW filter On selecting the Carrier Noise m
31. LE vows DL Ku 11900 0 MHz C N CAN Figura 40 Pantalla de comandos DiSEqC Cada vez que se env a un programa DiSEqC se env an tambi n los comandos que corresponden al estado del equipo con relaci n a la polarizaci n Horizontal o Vertical y banda Alta o Baja Esto permite asegurar que el estado de la instalaci n sea la que indica el equipo 5 19 Funci n SATCR Mediante la funci n SATCR es posible controlar los dispositivos de una instalaci n de TV sat lite que sean compatibles con la tecnolog a SatCR del ingl s Satellite Channel Router la cual permite concentrar m ltiples frecuencias de bajada slots por un nico cable De esta forma cada usuario utilizando un slot puede sintonizar y descodificar cualquier se al presente en el sat lite Para seleccionar la funci n SATCR pulsar la tecla DiSEqC 21 del panel frontal y mediante el selector rotativo 1 activar la opci n SATCR En la pantalla se muestran las opciones de configuraci n que el usuario puede modificar canal seleccionado n mero de canales activos direcci n del dispositivo paso de frecuencia habilitaci n de los pilotos de prueba y finalmente las frecuencias correspondientes a cada canal 8 SatCR es una marca registrada STMicroelectronics P gina 66 anda MANUAL DE INSTRUCCIONES PRODIG 5 ZRPROMAX Ta SATELITE SELECTED SLOT 1 J 20 IBUV dB Figura 41 Pantalla de comandos SatCR Al activar la opci n Ha
32. LR PROMAX MANUEL D UTILISATION PRODIG 5 2 touche kso 11 et au moyen de la mollette 1 choisir une tension de 13V Finalement choisir l application Essai F I Sat du menu d OUTILS 1 22 pour bande satellite ou bien l application Test Att nuation pour bande terrestre relier le g n rateur au point o sera branch e l antenne origine du signal et a l aide des touches de curseur horizontales 6 acc der la fonction talonner voir suivante figure Attendre quelques seconds jusqu ce qu il finisse le processus de calibrage des trois fr quences pilotes TALONNER Figure 15 Essai F I Sat Bande Satellite 2 MESURE DES TROIS PILOTES LE LONG DU RESEAU Une fois calibr le PRODIG 5 EXPLORER on peut se disposer a faire les mesures de niveaux dans les diff rentes prises de distribution au moyen du EXPLORER Sur l cran appara tront les valeurs des att nuations mesur es pour les trois fr quences pilotes dans une certaine prise voir la suivante figure ENE SORTIR Figure 16 Mesures d att nuation pour une prise Page 38 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX Pour finir les mesures pousser la mollette 1 et choisir ensuite l option SORTIR 11 2013 Page 39 AxPROMAX MANUEL D UTILISATION PRODIG 5 5 12 Fonction d Exploration du spectre EXPLORER La fonction d Exploration permet d explorer la bande de fr quences compl te pour identifier les canaux analogiqu
33. Utilidades pulsaci n corta Informaci n Equipo Presenta informaci n sobre el equipo PN n mero de producto N mero Referencia versi n del software de control configuraci n incluida etc Test Atenuaci n S lo en la banda terrestre Selecciona la funci n de comprobaci n de redes de distribuci n en banda terrestre Prueba FI Sat ICT S lo en la banda sat lite Selecciona la funci n de comprobaci n de redes de distribuci n en banda sat lite Hacer Adquisiciones Funci n para realizar adquisiciones de medidas de forma autom tica Ver Adquisiciones Visualiza la lista de adquisiciones realizadas Eliminar Adquisiciones Elimina una adquisici n realizada previamente Suprimir Planes Borra la tabla de canales seleccionada Suprimir Canales Elimina un canal de la tabla de canales activa Insertar Canales A ade un canal en la tabla de canales activa desde otra tabla de canales est ndar Salir Salida del men de Utilidades Activa el men de Preferencias pulsaci n larga Idioma Selecciona el idioma entre DEUTSCH ENGLISH ESPANOL FRAN AIS ITALIANO y PYCCKUM Sonido Teclas Activa ON o desactiva OFF el zumbador 11 2013 P gina 23 AxPROMAX Apariencia Sensor Luz Identificaci n Ter M n Ter Potencia M n Ter Nivel M n Sat Potencia C N Tiempo M x Identificar Banda Sat Apagado Auto Tiempo Desconexi n Unidades Selector Rotativo Salir MANUAL DE INSTRUCCI
34. called Reed Solomon is applied see following Figure Obviously the error rate after the corrector is lower to the error rate at the QAM decoder output This is the reason because this screen provides the BER measurement before FEC Forward Error Correction Page 52 11 2013 BER before FEC REED SOLOMON Figure 27 Digital reception system via cable The BER measurement is provided in scientific notation i e 1 0 E 5 means 1 0x10 that is to say one wrong bit of every 100 000 and through an analogue bar as its length is smaller the signal quality will be better The analogue representation is done on a logarithmic scale not linear With the aim to have a reference about the signal quality it is considered that a system has a good quality when it decodes less than one non correctable error for every transmission hour This border is known as QEF Quasi Error Free and it corresponds approximately to a BER before FEC of 2 0E 4 BER 2 0x10 that is to say two incorrect bits of every 10 000 This value is marked on the measurement bar of the BER and therefore BER for acceptable signals must be at the left side of this mark Below the BER analogue bar it is shown the tuned frequency or channel and the frequency deviation in kHz between the tuned frequency and the one which optimizes the BER i e 800 00 MHz 1 2 kHz This deviation must be adjusted specially from the C N measurement in satellite band by tuning again the
35. canal Pour la mesurer correctement il est indispensable de d finir le param tre Largeur Canal 11 2013 Page 45 ZXPROMAX MANUEL D UTILISATION PRODIG 5 C N Mesure hors du canal Le niveau de bruit est mesur a foruit fsyntonie Y Largeur Canal Pour la mesurer correctement le canal num rique doit tre syntonis sur sa fr quence centrale MER Rapport d erreur de la modulation CBER Mesure du BER taux d erreur pour le signal num rique avant la correction d erreurs BER avant FEC VBER Mesure du BER taux d erreur pour le signal num rique apr s la correction d erreurs BER apr s Viterbi Bande satellite Canaux analogiques Niveau Mesure de niveau de la porteuse syntonis e C N Relation entre la puissance du signal modul e et la puissance de bruit quivalent pour la m me large de bande Bande satellite Canaux num riques DVB S Puissance canal M thode automatique C N Relation entre la puissance du signal modul e et la puissance de bruit quivalent pour la m me large de bande MER Rapport d erreur de la modulation CBER Mesure du BER taux d erreur pour le signal num rique avant la correction d erreurs BER avant FEC VBER Mesure du BER taux d erreur pour le signal num rique apr s la correction d erreurs BER apr s Viterbi 3 apparaitra successivement et de mani re cyclique toutes les mesures disponibles pour le signal syntonis 5 14 1 TV analogique
36. central 3 a ef Pasar al modo Medidas 12 selecci n de medidas Si en la l nea inferior de la pantalla no aparece el mensaje MPEG 2 y por consiguiente la tasa de error es inaceptable girando el selector rotativo desviar la frecuencia de sinton a hasta que aparezca el mensaje MPEG 2 Finalmente resintonizar el canal para minimizar el offset de sinton a que optimiza el BER y por consiguiente minimizar el BER Si no se consigue detectar ning n canal MPEG 2 asegurarse de que los par metros de la se al digital sean correctos P gina 44 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX 5 14 Selecci n de las Medidas Las medidas disponibles dependen de la banda de frecuencias de operaci n terrestre o sat lite y del tipo de se al anal gica o digital Banda terrestre Canales anal gicos Nivel V deo Audio C N Medida de nivel de la portadora sintonizada Relaci n entre los niveles de la portadora de v deo a portadora de audio Relaci n entre la potencia de la se al modulada y la potencia de ruido equivalente para el mismo ancho de banda Banda terrestre Canales digitales DVB C y DVB T Potencia del Canal La potencia del canal se mide asumiendo que la densidad C N MER CBER VBER espectral de potencia es uniforme en todo el ancho de banda del canal Para que la lectura sea correcta es indispensable definir el par metro Ancho de Banda Medida fuera del cana
37. channel in frequency 0 mode 24 to the lower reachable value 5 14 5 2 DVB T signals Once determined the parameters of COFDM signal it will be possible to measure BER Two types of measurements appear Following is shown the BER measurement before the error corrections BER before the FEC CBER 11 2013 Page 53 ZXPROMAX USER S MANUAL PRODIG 5 DVB T COFDM 5 0E 4 Figure 28 Screen of CBER measurement COFDM signals In a reception system of terrestrial digital signal after the COFDM decoder two error correction methods are applied Obviously each time we apply an error corrector to the digital signal the error rate changes therefore if we measure the error rate at the output of the COFDM demodulator at the output of the Viterbi decoder and at the output of the Reed Solomon decoder we obtain nothing more than different error rates The PRODIG 5 EXPLORER provides the BER after Viterbi VBER BER before FEC MER CSI BER after Viterbi COFDM TUNER DEMOD VITERBI REED SOLOMON Figure 29 COFDM reception system DVB T COFDM 5 3E 4 Figure 30 Screen of BER measurement COFDM signals VBER Page 54 11 2013 The BER measurement is provided in scientific notation i e 3 1 E 7 means 3 1x10 that is to say 3 1 average value of wrong bits of each 10000000 and through a graphic bar as its length is smaller the signal quality will be better The analogue representation is done on a loga
38. de la identificaci n de una transmisi n TDT con una relaci n C N insuficiente TPS in lock TPS Transmission Parameter Signalling descodificados Los TPS son portadoras 17 en el sistema 2k y 68 en el sistema 8k moduladas en DBPSK con informaci n relacionada con la transmisi n modulaci n y codificaci n Tipo de modulaci n QPSK 16 QAM 64 QAM Jerarqu a Intervalo de Guarda Viterbi Code Rate Modo de Transmisi n 2k o 8k y N mero de Trama recibida MPEG 2 Detecci n correcta de una se al MPEG 2 5 14 5 3 Se ales DVB S Una vez establecidos los par metros de la se al QPSK ser posible medir el BER A continuaci n se presenta la medida del BER antes de la correcci n de errores BER antes del FEC CBER DVB S QPSK 9 7E 4 Figura 31 Pantalla de medida del CBER de se ales moduladas en QPSK P gina 56 ete MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX En un sistema de recepci n de se al digital v a sat lite tras el descodificador de se al QPSK se aplican dos m todos de correcci n de errores ver la siguiente figura Obviamente cada vez que se aplica un corrector de errores a la se al digital la tasa de error cambia por lo que si se mide la tasa de error a la salida del demodulador de QPSK despu s de Viterbi y a la salida del descodificador de Reed Solomon se obtienen tasas de errores distintas El PRODIG 5 EXPLORER proporciona la medida del BER despu s de Viterbi VBER BER before FEC BER a
39. de roll off a du filtre de Nyquist Code Rate Inversion spectrale VIDEO Format D codage services AXPROMAX 2k 8k S lectionnable par l utilisateur 1 4 1 8 1 16 1 32 S lectionnable par l utilisateur 1 2 2 3 3 4 5 6 7 8 QPSK 16 QAM 64 QAM S lectionnable ON OFF Indication de mode hi rarchique 16 32 64 128 256 QAM 1000 a 7000 kbauds 0 15 S lectionnable ON OFF 2 45 Mbauds 0 35 1 2 2 3 3 4 5 6 7 8 et AUTO S lectionnable ON OFF MPEG 2 DVB MP ML Liste de services et de PIDs MESURE DE SIGNAUX ANALOGIQUES MESURE DE NIVEAU Etendue de mesure Bandes TV terrestre et FM Bandes TV satellite Lecture Num rique Analogique Largeur de bande mesure Signal acoustique 11 2013 10 dBuV 120 dBuV 3 16 uV 1 V 30 dBuV 120 dByV 31 6 uV 1 V Echelle automatique vue la fen tre l cran Valeur absolue calibr e en dBuV dBmV ou dBm Valeur relative sur barre analogique sur l cran 230 kHz Bande terrestre 4 MHz Bande satellite Fris en bande 1 dB maximum Son NV Tonalit que varie avec le niveau du signal Seulement en mode pointage d antennes Page 5 AxPROMAX Pr cision Bandes terrestre Bandes satellite Indication de surmarge MODE MESURES Bandes terrestre Canaux analogiques Canaux num riques Bande satellite Canaux analogiques Canaux num riques Fonction SAISIES Canaux analogiques Canaux num riques Foncti
40. direct access to the various functions that are displayed simultaneously on screen The PRODIG 5 makes a dynamic exploration of the spectrum detecting all the channels in the explored band this applies for the terrestrial and the satellite television bands The meter locates all the channels in the spectrum with no need of any previous information about the number of channels the type of signals transmitted or their characteristics With the data collected after each exploration it creates a register that contains tables of channels that can be independent for each system or installation At any time the measurement sessions using only the pretuned channels can be repeated In this way it is possible to optimise the measurement process Shown on the frontal panel is the type of measurement that is being carried Terrestrial Satellite Analogue Digital and the data are presented on a hi res 5 graphic TFT display The equipment incorporates a light sensor that activates the contrast and luminosity of the display according to the environmental conditions The EXPLORER is an ideal size to hold with a hand The instrument can be held to the body with the carrying bag or transport belt which at the same time protects it from the rain Because it is designed for outdoor use it includes an anti shock protector that completely covers the instrument and optionally can be supplied with a strong transport case As well the front panel does not have any
41. frequency tuning to channel tuning and back again In channel tuning mode turning the rotary selector 1 sequentially tunes the channels defined in the active channels table When turning it clockwise frequency increases while turning it anticlockwise frequency decreases In frequency tuning mode there are two ways of tuning 1 Turning the rotary selector 1 Turning the rotary selector 1 selects the desired frequency tuning is continuous from 45 to 865 MHz and from 950 to 2150 MHz When turning it clockwise frequency increases while turning it anticlockwise frequency decreases 2 Using the keyboard Press the rotary selector 1 the frequency listing will disappear and will appear on the upper left corner of screen the keyboard symbol of manual data entry 123 next enter the frequency value in MHz using the numeric keyboard The EXPLORER will calculate the tuneable frequency closest to the entered value and then display it on screen 11 2013 Page 29 ZXPROMAX USER S MANUAL PRODIG 5 5 5 Automatic Transmission Search Holding pressed the 25 key search starts until it finds a transmission with a level higher than the search level The threshold level is defined by means of the Min Ter Level for analogue channels and Min Ter Power Min Sat Power for digital channels from PREFERENCES menu 5 6 Selecting the measurement configuration Analogue Digital signal Measuring the characteristics of a channel de
42. is completed with the instrument off the fan stops IMPORTANT The instrument battery needs to be kept charged between 30 and 50 of its capacity when not in use The battery needs to be fully charged for best results A fully charged battery suffers temperature related discharge For example at a room temperature of 20 C it can lose up to 10 of its charge over 12 months 3 2 Installation and Start up The PRODIG 5 EXPLORER level meter is designed for use as a portable device Therefore does not require installation When the rotary selector 1 is pressed for more than two seconds the instrument is started up in the automatic power off mode that is the device is automatically disconnected after the selected minutes if no key has been pressed When the device is operating it is also possible to select the auto power off mode by means of the Preferences menu 22 and to select the time out until the automatic power off Page 14 11 2013 4 QUICK USER GUIDE STEP 1 Battery charging 1 Connect the DC external charger to the equipment through connector 32 located on the lateral panel 2 Connect the DC charger to the mains 3 When the equipment is connected to the mains the CHARGER led 4 remains lighted CHARGER X X DC IN US Figure 1 Battery charging STEP 2 Power on and signal connection 1 Hold the rotary selector 1 pressed until the equipment is powered on 2 Connect the RF sig
43. keys nor gaps to avoid accidental water ingress The PRODIG 5 is designed to integrate measurements that require different operating configurations In this way it incorporates a specific function to facilitate the alignment of antennas When activating the alignment function the instrument is set automatically to offer a fast spectrum sweep and a high sensitivity graphical bar that allows fine adjust for the maximum signal In addition it includes a module for the powering of LNBs and DVB T antennas to 5V and the commands for the programming of DiSEqC 1 2 devices The EXPLORER can be updated to new software versions that extend the available functions in the future That means it can incorporate new benefits without additional cost For example in the test of satellite signals distribution networks the use in combination with an IF generator to carry out an easy verification of the installations before the operation begins The spectrum analyser features with high accuracy resolution sensitivity and sweep speed allows the instrument to be very useful for applications as the installation of antennas or the detection of complex impulsional noise events It presents an innovative control system based on four arrows that makes the use of the spectrum analyser very intuitive The arrows allow adjusting the reference level by steps of 10dB and the frequency margin span on screen Page 2 11 2013 To enhance its convenience of use it includes mem
44. la guardar con el nombre de la lista patr n original seguida de la extensi n _0x Ver la siguiente figura i CCIR 02 03 04 S01 S02 safer 68 69 STD CHANNEL PLAN o E CCIR_01 02 04 S03 sof 68 PARAMS NEW CHANNEL PLAN CCIR 02 03 04 So1 sale fer 68 69 STD CHANNEL PLAN CCIR_01 02 03 04 su fs 69 PARAMS CH04 Figura 10 Proceso de generaci n de nuevas listas de canales 11 2013 P gina 33 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 El usuario puede suprimir las listas de canales no deseadas eliminar y a adir canales de otra lista est ndar mediante las opciones de edici n que ofrece el men 8 UTILIDADES v 22 El EXPLORER permite cambiar directamente el canal sintonizado perteneciente a a la lista de canales activa mediante los cursores serra 6 De esta forma 0 Jul una vez seleccionado el campo de sinton a por canal 24 y en los modos de 3 1 operaci n de MEDIDAS 12 y de TV 10 es posible recorrer ciclicamente toda la lista de canales activa El s mbolo Kd en la esquina superior de la pantalla indica que el equipo est guardando informaci n en la memoria interna Este s mbolo aparece siempre que el usuario selecciona una opci n de registro de datos mediante la pulsaci n del selector rotativo 1 5 10 Funci n Adquisici n Adquisici
45. la marge de fr quences en cran Pour une meilleure commodit d utilisation il dispose de m moires pour conserver diff rentes mesures r alis es automatiquement le nom de l acquisition le point de la mesure la fr quence le plan de canaux etc La fonction DATALOGGER facilite norm ment la v rification des syst mes dans lesquels il est n cessaire de r aliser un nombre lev de mesures et rend possible un traitement post rieur de l ensemble de l information obtenue au moyen d un ordinateur PC En outre l appareil incorpore un g n rateur de commandes DiSEqC et le permet de fournir diverses tensions l unit externe 5 V 13 V 15 V 18 V 24 V Aussi l appareil dispose d une PRISE P RITEL ou connecteur Scart avec entr e sortie de vid o audio Le PRODIG 5 est aliment par batterie rechargeable ou bien reli au s cteur au moyen de l adaptateur DC externe fourni Incorpore une interface RS 232C pour faciliter les processus de diagnostic calibrage et configuration Cet appareil d sa conception ultra compacte sp cifications techniques et sous co t devienne le standard industriel pour l installateur z DiSEqc est une marque d pos e EUTELSAT 11 2013 Page 3 AxPROMAX 1 2 Sp cifications A MANUEL D UTILISATION PRODIG 5 CONFIGURATION POUR LA MESURE DU NIVEAU ET DE LA PUISSANCE SYNTONIE Modes d accord Plan de canaux R solution Recherche automatique Explorer Identif
46. la prise de terre correspondante Cet appareil peut tre utilis sur des installations de la Cat gorie de Surtension et D gr de Pollution 2 L alimentateur CC externe peut tre utilis sur des installations de la Cat gorie de Surtension Il D gr de Pollution 1 ne faudra employer quelconque des accessoires suivants que pour les types sp cifi s afin de pr server la s curit Batterie rechargeable Alimentateur CC externe Cable pour l allume cigares de l automobile C ble de s cteur Toujours tenir compte des marges sp cifi es tant pour l alimentation que pour effecteur une mesure N oubliez pas que les tensions sup rieures 60 V CC ou 30 V CA rms sont potentiellement dangereuses Observer toujours les conditions ambiantes maximales sp cifi es pour cet appareil En utilisant Palimentateur DC externe le n gatif de mesure se trouve sur le potentiel de terre Ne pas obstruer le syst me de ventilation Utiliser pour les entr es sorties de signal sp cialement avec niveaux hautes des c bles appropri s de bas niveau de radiation X Suivre strictement les recommandations de nettoyage d crites au paragraphe Entretien 11 2013 Page 9 AxPROMAX MANUEL D UTILISATION PRODIG 5 Symboles concernant la s curit Page 10 I gt e BO GiOtrede COURANT CONTINU COURANT ALTERNATIF ALTERNATIF ET CONTINU TERMINAL DE TERRE TERMINAL DE PROTECTION TERMINAL A LA CARCASSE EQUIPOTEN
47. le mode de mesure Au cas o l appareil travaillerait en bande satellite il montrera la position orbitale Pourvu que le processus d tecte de nouveaux param tres pour un canal ou une fr quence il cr era un nouveau plan de canaux en contenant l information d tect e Page 32 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX NOTE Dans le cas qui on souhaite identifier des signaux DVB C est n cessaire 8 d acc der pr alablement au menu de PR F RENCES 3 22 et de choisir comme Identificateur de signaux num riques terrestres le standard DVB C 5 9 Plan de Fr quences Tant le processus d identification automatique de signaux comme celui d exploration de spectre de fr quences peuvent g n rer la cr ation de nouveaux plans de canaux personnalis s et relatifs la localisation habituelle de travail de l appareil de mesure Ainsi la caract risation de la bande sera davantage d agile et simple quand l appareil analyse seulement un ensemble plus r duit de canaux Pourvu qu on active un nouveau processus d exploration le PRODIG 5 analyse tous les canaux pr sents dans la liste de canaux active laquelle agit comme liste patron sp cifi e par Poption PLAN FREQUENCES du menu de configuration de la D mesure CONFIGURATION 17 Si pendant le processus d exploration ou d identification automatique l EXPLORER d tecte de nouveaux param tres pour un certain canal ou fr quence produira un nouveau plan avec l inform
48. lista de canales Pulsar la tecla del teclado 8 correspondiente a la letra o d gito que se desee introducir Se puede escribir la palabra que se desee presionando la tecla en donde se encuentra la letra deseada Se deber pulsar cada tecla el n mero de veces que sea necesario antes de que transcurran dos segundos hasta que aparezca la letra o d gito adecuado en pantalla Para pasar de letras min sculas a may sculas y viceversa se debe apretar primero la tecla 25 cs Pulsar la tecla de cursor flecha superior Y 6 para cancelar una entrada de datos por el teclado Al mantener pulsada una tecla num rica en modo texto el numero correspondiente se introduce directamente P gina 68 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX 6 DESCRIPCI N DE ENTRADAS Y SALIDAS 6 1 Entrada de RF La entrada de RF se realiza a trav s del conector 80 en el panel lateral El nivel m ximo de la se al no debe superar en ning n caso 130 dBuV 6 2 Puerto Serie RS 232C El PRODIG 5 EXPLORER dispone de un puerto serie RS 232C para poder comunicarse con un PC mediante el software Pktools o NetUpdate y poder realizar procesos de diagnostico ajuste y calibraci n Las se ales en este conector se describen en la tabla 4 N A A Figura 42 Conector RS 232C Vista exterior Ne DE PIN SE AL CARACTER STICAS 1 Carrier Detect no conectado 2 Data Request R
49. log 10 100 dBuV Observemos que en este caso podemos tener adem s de p rdida de sinton a por sobrecarga de la entrada de RF otros efectos como saturaci n del tuner y generaci n de productos de intermodulaci n que enmascaren la visualizaci n del espectro 11 2013 P gina 47 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 5 14 2 TV anal gica Medida de la Relaci n V deo Audio V A En el modo de medida V deo Audio en el monitor aparece la siguiente informaci n TERRESTRIAL 16 2 dB 30 MHz LEVEL C N V A Figura 22 Medida de la relaci n v deo audio Adem s de la relaci n entre los niveles de la portadora de v deo y la portadora de audio 16 2 dB en el ejemplo de la figura anterior se muestra la frecuencia o el canal de acuerdo con el modo de sinton a seleccionado el nivel de la portadora de v deo y la relaci n Portadora Ruido 5 14 3 TV anal gica digital Medida de la Relaci n Portadora Ruido C N El PRODIG 5 EXPLORER realiza la medida de la relaci n C N de cuatro maneras diferentes de acuerdo con el tipo de portadora y la banda en uso A B C Banda terrestre portadora anal gica El nivel de portadora se mide mediante un detector de cuasi pico 230 kHz BW El nivel de ruido se mide mediante un detector de valor medio y se corrige para referirlo al ancho de banda equivalente de ruido del canal de acuerdo con su definici n para el est ndar
50. offrira l option de r p ter les mesures par exemple pour un autre point de mesure de visualiser les donn es obtenues en tournant la mollette 1 de stocker l information dans la m moire interne GARDER ou de quitter la derni re saisie r alis e SORTIR 5 10 1 Acquisitions pour Test Att nuation et Essai F I Sat Le PRODIG 5 permet d effectuer des acquisitions de mesures tandis qu il ex cute un Test d Att nuation dans la bande terrestre ou un essai F I Sat dans la bande satellite voir chapitre 5 11 V rification de r seaux de distribution Pour cela on a d avoir activ pr alablement un de ces deux essais comme on montre la figure suivante 11 2013 Page 35 AxPROMAX MANUEL D UTILISATION PRODIG 5 ETE SORTIR Figure 12 Test d Att nuation Bande terrestre Pour effectuer l acquisition automatique de ces mesures choisir le menu 8 d OUTILS en poussant la touche ru 22 et activer l option FAIRE SAISIES et ensuite l option NOUVELLE SAISIE Dans le champ PLAN DE FREQUENCES appara tra l essai que l appareil est en train d enregistrer automatiquement POINT DE MESURE PLAN FREQUENCES FREQ MHz REF kHz NIVEAU CAN COMMENCER SORTIR Figure 13 cran d acquisition pour les fr quences Test d Att nuation En choisissant l option COMMENCER l appareil obtiendra les valeurs correspondantes aux trois fr quences pilotes de la bande active Quand il aura fini l
51. por Frecuencia 0 Al pulsar la tecla 24 se conmuta de sinton a por frecuencia a sinton a por canal y viceversa En el modo sinton a por canal al girar el selector rotativo 1 se sintonizar n secuencialmente los canales definidos en la tabla de canales activa Al girarlo en el sentido de las agujas del reloj la frecuencia aumenta mientras que al girarlo en sentido contrario a las agujas del reloj la frecuencia disminuye En el modo sinton a por frecuencia existen dos m todos de sinton a 1 Girando el selector rotativo 1 Actuando sobre el selector rotativo 1 seleccionamos la frecuencia deseada la sinton a es continua de 45 a 865 MHz y de 950 a 2150 Hz Al girarlo en el sentido de las agujas del reloj la frecuencia aumenta mientras que al girarlo en sentido contrario a las agujas del reloj la frecuencia disminuye 11 2013 P gina 29 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 2 Introducci n por teclado Pulsar el selector rotativo 1 la indicaci n de frecuencia desaparecer y aparecer en la parte superior izquierda de la pantalla el s mbolo de entrada de datos manualmente 123 a continuaci n mediante el teclado num rico introducir el valor de la frecuencia deseada en MHz El PRODIG 5 EXPLORER calcular la frecuencia sintetizable m s pr xima al valor introducido y la presentar en el monitor 5 5 B squeda Autom tica de Emisoras Pulsando la tecla 25 se efect a un rastreo hasta que encu
52. programa de audio APID la velocidad de transmisi n del v deo VIDEO del audio AUDIO y el tipo de codificaci n MPEG 1 MPEG 2 AC 3 lt gt Al pulsar una flecha de cursor 6 aparecer de nuevo la ventana con la informaci n de sinton a para que la informaci n permanezca fija se deben pulsar los cursores verticales 6 hasta seleccionar el campo OSD OFF a continuaci n pulsar el selector rotativo 1 para conmutar a OSD ON Si la emisi n no est codificada aparecer en la esquina superior derecha la indicaci n LIBRE en caso contrario COD Tambi n se indica el perfil del est ndar MPEG 2 que define la tasa de compresi n del servicio digital que est siendo descodificado el nivel de resoluci n de la imagen 4 3 la resoluci n filas x columnas del v deo recibido y la frecuencia de refresco de la imagen En modo OSD OFF la ventana de informaci n descrita aparecer tambi n siempre que se pulse de nuevo el selector rotativo 1 P gina 62 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX Figura 37 Visualizaci n de un canal anal gico NOTA El s mbolo x en la esquina superior de la pantalla indica que el equipo ha detectado una situaci n de saturaci n de se al anal gica en el canal sintonizado Este s mbolo aparece tambi n cuando la se al subportadora de color Burst no contiene informaci n y por tanto las im genes se muestran en blanco y negro Cuando se descodif
53. pulsaci n repetida de la tecla uno 3 activa secuencialmente los men s de control del VOLUMEN CONTRASTE BRILLO SATURACI N y MATIZ s lo en el sistema de color NTSC Al activar el men correspondiente a cada par metro en el monitor aparece una barra horizontal cuya longitud es proporcional al nivel del par metro para modificar su valor debe girar el selector rotativo 1 Para salir de este men debe pulsar el selector rotativo 1 P gina 28 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX 5 3 Selecci n del Modo de Operaci n TV Analizador de Espectros Medidas El PRODIG 5 EXPLORER posee tres modos de operaci n b sicos modo de operaci n TV modo de operaci n analizador de espectros y modo de Medidas Para pasar del modo TV al modo de Analizador de Espectros se debe pulsar la tecla em En 13 Para pasar al modo de Medidas pulsar la tecla ver 12 En el modo de operaci n TV en el monitor se presenta la se al de televisi n demodulada este es el modo de operaci n por defecto y sobre l pueden seleccionarse m ltiples funciones tal como se muestra en los pr ximos p rrafos En el modo analizador de espectros en el monitor aparece una representaci n del espectro de la banda activa terrestre o sat lite el span y el nivel de referencia En el modo de Medidas en el monitor se muestran las medidas disponibles en funci n del tipo de se al seleccionada 5 4 Sinton a por Canal Sinton a
54. punto de medida visualizar los datos girando el selector rotativo 1 almacenar la informaci n en la memoria del equipo GUARDAR o abandonar la adquisici n realizada SALIR 5 10 1 Adquisiciones para Test de Atenuaci n y prueba FI SAT ICT El PRODIG 5 permite activar la funci n de adquisici n autom tica mientras ejecuta un Test de Atenuaci n en la banda terrestre o una prueba FI SAT ICT en la banda sat lite ver apartado 5 11 Comprobaci n de redes de distribuci n Para ello es necesario haber activado previamente una de estas dos pruebas como muestra la siguiente figura 11 2013 P gina 35 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 NETO SALIR Figura 12 Test de Atenuaci n Banda terreste A continuaci n acceder al men de UTILIDADES pulsando la tecla vov 22 y activar la opci n HACER ADQUISICIONES y despu s la opci n NUEVA ADQUISICI N En el campo CANALIZACI N aparecer el tipo de prueba que el equipo registrar autom ticamente PUNTO DE MEDIDA PUN CANALI ZACI ON TE FREC MHz M REF kHz NIVEL CAN INICIAR ETT Figura 13 Pantalla de adquisici n para las frecuencias Test Atenuaci n Al seleccionar la opci n INICIAR el medidor obtendr los valores correspondientes a las tres frecuencias piloto de la banda activa Al finalizar la captura de datos ofrecer la posibilidad de guardar la adquisici n realizada o iniciar una nueva P gina 36 11 2013 MANUAL DE
55. que pueden aparecer y su significado se muestra en la siguiente lista Los mensajes se presentan por orden de menor a mayor cumplimiento de los requerimientos del est ndar MPEG 2 Se al no detectada No se ha detectado ninguna se al Se al detectada Se ha detectado una se al pero no es descodificable Portadora recuperada Se ha detectado una portadora digital pero no es descodificable Viterbi sincronizado Detecci n de una portadora digital y sincronizaci n del algoritmo de Viterbi pero llegan demasiadas tramas con errores no corregibles No se puede cuantificar el BER MPEG 2 Detecci n correcta de una se al MPEG 2 5 14 6 TV Digital Medida del MER Una vez establecidos los par metros de recepci n apropiados para la se al 3 A a COFDM QAM o QPSK ser posible medir el MER pulsar la tecla er 12 hasta que aparezca la pantalla de medida del MER DVB T COFDM 19 5 dB mr s 4aB 30 40 dB dB Figura 34 Pantalla de medida del MER para se ales DVB T moduladas en COFDM P gina 58 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX En primer lugar se presenta la medida de la relaci n de error de modulaci n MER A continuaci n aparece la medida del Margen de Ruido MR en la figura anterior de valor 8 4 dB Indica un margen de seguridad respecto al nivel del MER medido para la degradaci n de la se al hasta llegar al valor del QEF Quasi Error Free Las portadoras anal gicas y digitale
56. s lectionn B Bande terrestre porteuse num rique Les deux mesures sont effectu es l aide d un d tecteur de valeur moyenne 230 kHz BW et les m mes corrections sont introduites dans les deux corrections de largeur de bande C Bande satellite porteuse analogique Le niveau de porteuse est mesur l aide d un d tecteur de cr te 4 MHz BW Le niveau de bruit est mesur l aide d un d tecteur de valeur moyenne 230 kHz et est corrig pour faire r f rence la largeur de bande du canal D Bande satellite porteuse num rique quivalent au cas B mais en utilisant dans ce cas un filtre de mesure de 4 MHz En s lectionnant le mode de mesure Carrier Noise l information ci dessous appara tra sur le moniteur TERRESTRE 40 1 dB 10 MHz NIVEAU C N V A Figure 23 Mesure du rapport porteuse bruit C N 11 2013 Page 49 AXxPROMAX MANUEL D UTILISATION PRODIG 5 En plus du rapport entre la porteuse de vid o et le niveau de bruit C N 40 1 dB dans l exemple de la figure pr c dente la fr quence ou le canal sera pr sent conform ment au mode de syntonie s lectionn ainsi que le niveau de la porteuse de vid o et le rapport vid o audio Repr senter le spectre en poussant la touche 5 aa 13 le curseur de NOISE est automatiquement plac a un c t de la porteuse accord e C est a dire le curseur indiquera le point ot la valeur du bruit est plus
57. syntonis e Dans le moniteur appara tra l image de TV avec une fen tre sur la partie inf rieure de l image pendant cinq seconds pour montrer dans le cas que le signal soit analogique le num ro de canal la fr quence le plan de canaux actif le syst me de couleur et le standard de TV 11 2013 Page 61 AxPROMAX MANUEL D UTILISATION PRODIG 5 DTv CN VPID APID OSD ON MP ML CANAL 66 720x576i CCIR 4 3 50 Hz DVB T 834 00 MHz Component A SID RES VistaNetw NID VIDEO kbit s MPEG 2 SON 2 kbit s MPEG 1 L 2 E Figure 36 Visualisation d un canal num rique Si le signal est num rique les param tres suivants pendant cinq seconds seront montr s num ro de canal fr quence plan de canaux actif type de signal DVB nom du service identificateur du service SID nom du r seau identificateur du r seau NID identificateur de programme de vid o VPID identificateur de programme d audio APID vitesse de transmission du vid o VID O de l audio AUDIO et type de codification MPEG 1 MPEG 2 6 AC 3 gt En poussant une fl che de curseur 6 appara tra de nouveau la fen tre avec l information de a pour que l information reste fixe doivent tre pouss s les curseurs verticaux 6 jusqu choisir le champ OSD OFF ensuite pousser la mollette 1 pour changer OSD ON Si l mission n est pas codifi e appara tra dans le coin inf rieur droit l indication C
58. une marque d pos e EUTELSAT 11 2013 Page 7 ZXPROMAX MANUEL D UTILISATION PRODIG 5 Consommation 35 W Arr t automatique Apr s les minutes choisies sans utilisation Supprimible CONDITIONS D ENVIRONNEMENT DE FONCTIONNEMENT Altitude Jusqu a 2000 m Marge de temp ratures De 5 a 40 C D branchement automatique par exc s de temp rature Humidit relative maximale 80 jusqu a 31 C d croissance lin aire jusqu a 50 a 40 C CARACTERISTIQUES MECANIQUES Dimensions 230 L x 161 H x 76 Pr mm Volume total 2 814 cm Poids 1 9 kg sans protecteur antichoc ACCESSOIRES INCLUS 1x CB 077 Batterie rechargeable Li 7 2 V 11 Ah 1x AT 010 Att nuateur 10 dB 1x AD 055 Adaptateur F H BNC H 1x AD 056 Adaptateur F H DIN H 1x AD 057 Adaptateur F H F H 1x AL 103 Alimentateur CC externe 1x DC 265 Etui de transport 1x DC 289 Ruban de transport 1x AA 103 Adaptateur pour l allume cigares de l automobile 1x CA 005 C ble de secteur ACCESSOIRES OPTIONNELS DC 229 Valise de transport DC 266 Etui protecteur Page 8 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX 2 PRESCRIPTIONS DE S CURIT 2 1 G n rales Nutiliser l quipement que sur des syst mes dont le n gatif de mesure est connect au potentiel de terre Lalimentateur CC externe AL 103 s agit d un appareil de type I Pour des raisons de s curit il doit tre branch aux lignes du r seau avec
59. vertically the lower frequencies appear at the left of the screen and the higher ones at the right The amplitude of the lobes is calibrated In the example in previous figure the noise level is at around 25 dBuV and the lobe with the highest signal level third from the right is at 70 dBuV The frequency range displayed called span from hereon can also be altered using the horizontal cursors 6 keys Therefore enables selecting the displayed screen frequency range in Spectrum Analyser mode between Full the entire band 500 MHz 200 MHz 100 MHz 50 MHz 32 MHz 16 MH and 8 MHz the latter one only in terrestrial bands A vertical broken line called marker appears on the spectrum display to identify the tuned frequency One of the applications of the PRODIG 5 operating as Spectrum Analyser is in the search for the best orientation and position of the receiving antenna This is particularly important in UHF Because such frequencies are involved with wavelengths ranging from 35 cm to 65 cm if the antenna is shifted only a few centimetres the relationship between the picture chrominance and sound carrier frequencies change affecting the quality of the picture in the receiver Page 60 11 2013 If there is an excess of sound carrier tearing or moir may appear on the screen due to the frequency beats between the sound chrominance and the picture frequencies If there is a chrominance carrier defect then the television co
60. 2 Fonctionnement avec batterie wild 3 1 2 1 Charge de la batterie 14 3 2 Installation et Mise en Marche 14 4 GUIDE RAPIDE D UTILISATION ss 15 5 MODE DEMPLO Lito 19 5 1 Description des Commandes et des l ments ocoicicccccconicnnncnonocnoninacionocnnnono 19 5 2 R glage des Param tres du Moniteur et du Volume 28 5 3 S lection du Mode d Op ration TV Analyseur de Spectre Mesures se 5 4 Syntonie par Canal Syntonie par Fr quence eeeeeeeeceeeeeeeeeeeeeeeeeeeeeeeeaee 5 5 Recherche Automatique d metteurs 5 6 S lection de la Configuration de Mesure Analogique Num rique 5 7 Alimentation des Unit s Externes oooooncccnccnnccccccconcncncccanccnnnnonncnnn 5 8 Fonction d ldentification Automatique de signaux AUTO ID 5 9 Plan de FreQuenGes simi ainia 5 10 Fonction Datalogger Saisies 5 10 1 Acquisitions pour Test Att nuation et Essai F I Sat 5 11 V rification de r seaux de distribution 5 12 Fonction d Exploration du spectre EXPLORER as 5 13 Configuration des Mesures sise 5 13 1 Configuration d un Canal Num rique DVB C QAM cooccccccoccnccncnnanconannnos 5 13 2 Configuration d un Canal Num rique DVB T COFDM exe 5 13 3 Configuration d un Canal Num rique DVB S QPSK assesseer 5 14 S lection des Mesures 5 14 1 TV analogique Mesure du Niveau de la Porteuse de Vid o 5 14 2 TV analogique Mesure du Rapport Vid o Audio V A
61. 50 RP 250 Fonction pour utiliser avec le g n rateur de signaux RP 080 RP 250 Page 6 11 2013 MANUEL D UTILISATION PRODIG 5 PR SENTATION EN MONITEUR Moniteur Syst me de couleur Standard de TV Fonction de spectre Sensibilit SIGNAL EN BANDE DE BASE VIDEO Entr e vid o externe Sensibilit Sortie de vid o SON Entr e Sorties D modulation D saccentuacion Sous porteuse INTERFACE RS 232C ALIMENTATION DES UNITES EXTERIEURES Terrestre et satellite Signal de 22 kHz Tension Fr quence Puissance maximum GENERATEUR DiSEqC ALIMENTATION Interne Batterie Autonomie Temps de charge Externe Tension AXPROMAX TFT couleur 5 PAL SECAM et NTSC M N B G 1 D KetL Expansion marge dynamique et niveau de r f rence variables au moyen de fl ches de curseur 40 dBuV pour synchronisme correcte Prise P ritel 1 Vpp 75 Q vid o positive Prise P ritel 75 Q Prise P ritel Haut parleur incorpor prise P ritel Syst mes PAL SECAM NTSC selon standard DVB T DVB C DVB S et MPEG 50 us Synt se num rique de fr quence selon standard de TV Pour des op rations d entretien et calibrage Par le connecteur d entr e RF Externe ou 5 13 15 18 24 V S lectionnable en bande satellite 0 6V 0 2V 22 kHz 4 kHz 5W Standard DiSEqC 1 2 Batterie Li lon de 7 2 V 11 Ah gt 3 5 heures sans interruption 3 heures au 80 appareil teint 12V s DiSEqc est
62. AL la frecuencia de medida del ruido corresponder a la posici n del cursor de color verde y trazo discontinuo que aparece en la representaci n del espectro Je 13 Para modificar esta frecuencia pulsar la tecla de configuraci n de medidas Al D E 17 acceder al men de CONFIGURACI N Al girar el selector rotativo 1 podr situar el cursor de NOISE sobre la posici n del marcador con la opci n FREC RUIDO AL CURSOR ver apartado 5 15 1 Marcadores o introducir directamente el valor de la nueva frecuencia del ruido mediante la opci n FREC RUIDO 11 2013 P gina 49 AXxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 FREC E 1 MHz _ N REF 16 5 dB Figura 24 Cursor NOISE C N MANUAL En el caso de medidas de canales en la banda de sat lite o de canales digitales para que la medida de la relaci n C N sea correcta es imprescindible haber definido previamente el ancho de banda del canal mediante la funci n Ancho de Banda del AD men Configuraci n de Medidas que aparece al pulsar la tecla _ 17 NOTA IMPORTANTE Para medir correctamente la relaci n C N de canales digitales es imprescindible sintonizar el canal en su frecuencia central En el caso de la presencia de canales digitales adyacentes stos pueden llegar a afectar la lectura del valor de ruido P gina 50 ete MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX 5 14 4 TV digital Medida de Potencia de un Canal Potencia El PRODIG 5 EXP
63. ATION PAS 1 Charge de la batterie 1 Relier l alimentateur DC externe l appareil travers le connecteur 32 situ dans le panneau lat ral droit 2 Relier l alimentateur DC au r seau 3 Quand l appareil est reli au r seau l indicateur luminaux CHARGER 4 reste actif CHARGER X DC IN Figure 1 Charge de la batterie PAS 2 Mise en marche et connexion de signaux 1 Maintenir la mollette 1 pouss e jusqu ce que l appareil se mette en marche 2 Relier la source de signal RF dans le connecteur d entr e 30 RF SOURCE ES E ane Figure 2 Mise en marche et connexion de signaux 11 2013 Page 15 AXxPROMAX MANUEL D UTILISATION PRODIG 5 PAS 3 Pour faire une exploration compl te de la bande de canaux 5 SSS 1 Choisir la bande de fr quences d exploration eal 14 terrestre ou satellite 2 Activer le processus d exploration en maintenant pouss e la touche 25 1 3 Pousser _e 10 pour visualiser les canaux d tect s et 6 6 pour changer de canal dans le plan de canaux d tect s PAS 4 Pour faire une identification du canal syntonis 5 Is 1 Choisir la bande de fr quences d exploration ae 14 terrestre ou satellite 2 Activer le processus d identification en poussant une fois sur la touche 25 1 3 Pousser _e 10 pour visualiser le signal d tect le canal ou la fr quence 4 identifi e o
64. ATTERIE AAA ARR T EN MARCHE Tableau 1 Indication de l tat de charge de la batterie CHARGER 3 1 2 Fonctionnement avec batterie Pour faire fonctionner cet appareil avec la batterie il suffit de d brancher Palimentateur CC externe et d appuyer sur la mollette 1 pendant plus de deux seconds Avec la batterie charg e l appareil poss de une autonomie minimale sup rieure 3 5 heures de fonctionnement ininterrompu Si la batterie se trouve presque d charg e le circuit de protection de la batterie emp chera le d marrage de l appareil Dans ce cas il faut proc der imm diatement au rechargement de la batterie Avant d effectuer une mesure quelle qu elle soit il est n cessaire de v rifier l tat de charge de la batterie l aide de l indicateur de niveau de charge de la batterie qu il appara t en activant le mode de mesure ser 12 Ceux ci sont les symboles indicateurs 11 2013 Page 13 AxPROMAX MANUEL D UTILISATION PRODIG 5 INDICATEURS DU NIVEAU DE CHARGE DE LA BATTERIE COULEUR SYMBOLE NIVEAU DE CHARGE 75 100 30 75 10 30 lt 10 Batterie en charge Tableau 2 Indicateurs du niveau de la batterie 3 1 2 1 Charge de la batterie Pour recharger compl tement la batterie connectez l appareil a l alimentateur CC externe sans appuyer sur la mollette 1 Le temps de recharge d pend de l tat de la batterie Si elle se t
65. ER VBER MER C N Num rica y barra de nivel Potencia BER MER C N Num rica y barra de nivel Potencia CBER VBER MER C N Num rica y barra de nivel 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX PAR METROS SE AL COFDM Portadoras Intervalo de guarda Code Rate Modulaci n Inversi n espectral Jerarqu a PAR METROS SE AL QAM Demodulaci n Velocidad de s mbolo Factor de roll off a del filtro de Nyquist Inversi n espectral PAR METROS SE AL QPSK Velocidad de s mbolo Factor de roll off a del filtro de Nyquist Code Rate Inversi n espectral V DEO Formato Descodificaci n servicios 2k 8k Seleccionable por el usuario 1 4 1 8 1 16 1 32 Seleccionable por el usuario 1 2 2 3 3 4 5 6 7 8 QPSK 16 QAM 64 QAM Seleccionable ON OFF Indicaci n de modo jer rquico 16 32 64 128 256 QAM 1000 a 7000 kbauds 0 15 Seleccionable ON OFF 2 a 45 Mbauds 0 35 1 2 2 3 3 4 5 6 7 8 y AUTO Seleccionable ON OFF MPEG 2 DVB MP O ML Lista de servicios y PIDs MEDIDA DE SE ALES ANAL GICAS MEDIDA DE NIVEL Margen de medida Bandas TV terrestre y FM Banda TV sat lite Lectura Indicaci n Num rica Indicaci n Gr fica Ancho de banda de medida Indicaci n ac stica 11 2013 10 dBuV a 120 dBuV 3 16 pV a 1 V 30 dBuV a 120 dBpV 31 6 pV a 1 V Autorrango se muestra sobre una ventana OSD Valor absoluto seg n par metros Barra anal gica en pantalla
66. G 5 analyses all the present channels in the active channel plan which acts as pattern channel plan specified by means of the option CHANNEL SET from configuration measurement D menu CONFIGURATION 17 If during exploration or automatic identification process the EXPLORER detects new parameters for some channel or frequency a new list will be generated with the information updated and will be saved with the name of the original channel plan followed by the extension _Ox See the following Figure f CCIR 02 03 04 S01 S02 saffar 68 69 STD CHANNEL PLAN o EXPLORER CCIR_01 02 04 S03 afi 65 68 PARAMS NEW CHANNEL PLAN CCIR 02 03 04 S01 S02 ll 67 68 69 STD CHANNEL PLAN e CCIR_01 02 03 04 su fs 69 PARAMS CH04 Figure 10 New channel plan generation process The user can delete any channel list or remove and add channels from another 8 standard list by means of the editing options offered by the ov UTILITIES 22 menu The EXPLORER allows directly changing the tuned channel pertaining to the active channel plan by means of the horizontal cursors 6 From this way once selected 0 1 the channel tuning field 24 and in the TV 10 and MEASUREMENTS se 12 operation modes is possible to check cyclically the entire active channel list 11 2013 Page 33 ZXPROMAX USER
67. Hz 50 MHz 32 MHz 16 MHz y 8 MHz el ltimo s lo en la banda terrestre En la representaci n del espectro aparece una l nea vertical discontinua que llamaremos marcador la cual identifica la frecuencia sintonizada P gina 60 141 2013 MANUAL DE INSTRUCCIONES PRODIG 5 ZXPROMAX Una de las aplicaciones del PRODIG 5 como analizador de espectros es buscar la mejor orientaci n y ubicaci n de la antena receptora Esta aplicaci n es especialmente til en la banda de UHF debido a que al trabajar con frecuencias altas y por lo tanto con longitudes de onda comprendidas entre 35 cm y 65 cm al desplazar unos pocos cent metros la antena la relaci n entre las frecuencias portadoras de imagen crominancia y sonido var a sustancialmente afectando a la calidad de la imagen en el receptor Si existe un exceso en la portadora de sonido puede aparecer en pantalla del televisor una perturbaci n o moir debida a batidos de frecuencias entre el sonido crominancia y las propias frecuencias del v deo Si existe un defecto de portadora de crominancia obligamos al amplificador de color del televisor a trabajar en condiciones de m xima ganancia pudiendo producir ruido que se manifestar por toda la pantalla del televisor con unos puntos de color que desaparecen al disminuir el control de saturaci n en caso extremo incluso se puede llegar a la p rdida de color 5 15 1 Marcadores S lo en el modo analizador de espectros El marcador
68. LAIR en cas contraire COD On indique aussi le profil du standard MPEG 2 qui d finit le taux de compression du service num rique qu est d cod le niveau de r solution de l image 4 3 la r solution files x colonnes du vid o regu et la fr quence de rafraichissement de l image Dans le mode OSD OFF la fen tre d information d crite appara tra pourvu qu on pousse de nouveau la mollette 1 Page 62 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX Figure 37 Visualisation d un canal analogique Le symbole X lt dans le coin sup rieur de l cran indique que l appareil a d tect une situation de saturation de signal analogique dans le canal syntonis Ce symbole appara t aussi quand le signal subporteuse de couleur Burst ne contient pas une information et par cons quent les images sont montr es en blanc et noir Quand on d code un canal num rique une fois finie l acquisition du tableau de services SDT Service Description Table sera possible d acc der la liste de services contenus dans ce tableau Pour cela situer le s lecteur de champ au moyen des curseurs verticaux 6 sur le champ du service actif p e Veo TV dans la figure suivante et pousser ensuite la mollette 1 Apparaitra alors le menu SERVICES DIGITALS avec les services disponibles dans le M ltiplex num rique D placer les curseurs verticaux 6 ou tourner la mollette 1 et le pousser pour choisir le service qui on souhait
69. LORER mide la potencia del canal en el ancho de banda del filtro de medida y estima la potencia total del canal asumiendo que la densidad espectral es uniforme en todo el ancho de banda del canal Al seleccionar el modo de medida POTENCIA CANAL en el monitor aparece la siguiente informaci n E DVB T COFDM POTENCIA 55 8 dBuV 10 30 50 Figura 25 Medida de la potencia de canales digitales Adem s de la potencia del canal digital 55 8 dBuV en el ejemplo de la figura anterior se muestra la frecuencia de sinton a o el canal de acuerdo con el modo de sinton a seleccionado y la frecuencia de desplazamiento para el c lculo de la potencia del canal digital Para que la medida de potencia de un canal digital sea correcta es imprescindible haber definido previamente el ancho de banda del canal mediante la funci n Ancho de A A Banda del men Configuraci n de Medidas que aparece al pulsar la tecla 17 5 14 5 TV digital Medida del BER El PRODIG 5 EXPLORER permite medir la tasa de error BER de una se al digital de tres formas diferentes dependiendo del tipo de modulaci n empleada Para seleccionar la de medida del BER 11 2013 P gina 51 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 1 Seleccionar la Configuraci n de Medidas de se ales digitales pulsando la tecla D 17 2 Seleccionar mediante la opci n Se al del men de CONFIGURACI N DVB C para la medida de se ales moduladas en QA
70. LR PROMAX MANUAL DE INSTRUCCIONES PRODIG 5 5 14 5 2 Se ales DVB T Una vez establecidos los par metros de la se al COFDM ser posible medir el BER Se presentan dos medidas A continuaci n se presenta la medida del BER antes de la correcci n de errores BER antes del FEC CBER EN DVB T COFDM 5 0E 4 Figura 28 Pantalla de medida del CBER de se ales moduladas en COFDM En un sistema de recepci n de se al digital terrestre tras el descodificador de se al COFDM se aplican dos m todos de correcci n de errores Obviamente cada vez que se aplica un corrector de errores sobre la se al digital la tasa de error cambia por lo que si se mide la tasa de error a la salida del demodulador de COFDM despu s de Viterbi y a la salida del descodificador de Reed Solomon se obtienen tasas de error distintas El PRODIG 5 EXPLORER proporciona la medida del BER despu s de Viterbi VBER BER before FEC MER CSI BER after Viterbi COFDM TUNER DEMOD VITERBI REED SOLOMON Figura 29 Sistema de recepci n COFDM P gina 54 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX La medida del BER se presenta en valor absoluto en notaci n cient fica 3 1 E 7 significa 3 1x10 es decir en valor medio 3 1 bits err neos cada 10 000 000 y mediante una barra anal gica cuanto menor sea su longitud mejor ser la calidad de la se al La representaci n anal gica se presenta sobre una escala logar tmica no lineal es
71. LY 32 en el panel lateral derecho del PRODIG 5 EXPLORER Conectar el alimentador DC a la red A continuaci n pulse el selector rotativo 1 durante m s de dos segundos En estas condiciones el medidor de nivel est en funcionamiento y se realiza una carga lenta de la bater a Cuando el equipo est conectado a la red el indicador luminoso CHARGER 4 permanece encendido Este indicador cambia de color seg n el estado de carga de la bater a ESTADO DE CARGA DE LA BATER A APAGADO EN MARCHA ROJO AMARILLO VERDE Tabla 1 Indicaci n del estado de carga de la bater a CHARGER 3 1 2 Funcionamiento mediante Bater a Para que el equipo funcione mediante bater a basta desconectar el alimentador DC externo y pulse el selector rotativo 1 durante m s de dos segundos Con las bater as cargadas el equipo posee una autonom a m nima superior a tres horas y media de funcionamiento ininterrumpido Si la bater a est muy descargada el circuito desconectador de bater a impedir que el aparato se ponga en funcionamiento En este caso debe ponerse a cargar la bater a inmediatamente Antes de realizar cualquier medida es necesario comprobar el estado de carga de la bater a mediante el indicador de nivel de carga que aparece activando el modo de 3 gt medida ber 12 Estos son los iconos indicadores 11 2013 P gina 13 LR PROMAX MANUAL DE INSTRUCCIONES PRODIG 5 INDICADORES DEL NIVEL DE CARGA DE LA BA
72. M DVB T para la medida de se ales moduladas en COFDM o DVB S para la medida de se ales moduladas en QPSK Los m rgenes de frecuencia admisibles son los siguientes Se ales DVB C QAM 45 MHz a 865 MHz Se ales DVB T COFDM 45 MHz a 865 MHz Se ales DVB S QPSK 950 MHz a 2150 MHz 3 Introducir los par metros relativos a la se al digital que aparecen en el men de CONFIGURACI N de la medida seg n se ha descrito anteriormente 4 Seleccionar la opci n salir del men de CONFIGURACI N de las medidas 5 14 5 1 Se ales DVB C Una vez establecidos los par metros de la se al QAM ser posible medir el 3 cn C2 BER pulsar la tecla 12 hasta que aparezca la pantalla de medida del BER En el modo de medida del BER el monitor mostrar una pantalla como la siguiente Y DVB C QAM 3 4E 4 Figura 26 Pantalla de medida del BER de se ales moduladas en QAM Pagina 52 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 LR PROMAX Se presenta la medida del BER antes de la correcci n de errores BER antes del FEC En un sistema de recepci n de se al digital v a cable tras el demodulador de se al QAM se aplica un m todo de correcci n de errores denominado de Reed Solomon ver la siguiente figura Obviamente la tasa de error tras el corrector es inferior a la tasa de error a la salida del demodulador de QAM Es por ello que en esta pantalla se proporciona la medida del BER antes de la correcci n de errores BER
73. MANUAL When measuring channels in the satellite band or digital channels to measure the C N ratio correctly the bandwidth of the channel must be defined previously using the Channel BW option on the Measurements Configuration menu that appears vw A when pressing 17 key IMPORTANT REMARK In order to measure digital channel C N ratio it is indispensable to tune channel at its central frequency In the case of the presence of adjacent digital channels these could mask the noise level measurement 5 14 4 Digital TV Measuring the Power of Digital Channels The PRODIG 5 EXPLORER measures digital channel power in the measurement filter bandwidth and estimates total channel power assuming that spectral density is uniform throughout channel bandwidth On selecting the CHANNEL POWER measurement mode the screen displays the following information Page 50 11 2013 E DVB T COFDM POWER 55 8 dBuV Figure 25 Digital channel power measurement In addition to the power of the digital channel 55 8 dBuV in previous figure this also shows the tuning frequency or channel depending on the tuning mode selected and the offset frequency to calculate the digital channel power For the power measurement of a digital channel to be correct it is essential to have previously defined the channel bandwidth using the Channel BW option in the D Measurements Configuration menu that appears when pressing 17 key 5
74. Mesure du Niveau de la Porteuse de Vid o Dans le mode de mesure de signaux analogiques le moniteur du PRODIG 5 EXPLORER peut agir comme un indicateur analogique du niveau du signal au moyen d une barre analogique sur l cran Page 46 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX 3 or Pour changer le mode de mesure on doit pousser la touche 12 jusqu qu il apparaisse un cran comme le suivant TERRESTRE NIVEAU 78 2 dBuV 110 NIVEAU C N V A Figure 21 Mesure du niveau de signal analogique en bande terrestre En tournant la mollette 1 on change le canal fr quence de syntonie Pousser la 3 touche se 12 pour choisir le type de mesure qui on souhaite visualiser dans le moniteur Les types de mesures disponibles sont NIVEAU Indication de niveau dans la partie sup rieure de l cran barre analogique C N Mesure de la relation porteuse bruit V A Mesure de la relation video audio 11 2013 Page 47 lt _ LL ZXPROMAX MANUEL D UTILISATION PRODIG 5 PRECAUTION Quan un grand nombre de porteuses haute intensit se trouvent a l entr e RF Pour d terminer le niveau quivalent d un groupe de porteuses a intensit s semblables a l entr e RF l expression suivante peut tre utilis e Ly L 10logN Ly intensit totale L niveau moyen du groupe de porteuses N nombre de porteuses pr sentes Ainsi pour 10 porteuses d un niveau de 90 dBuV
75. N OFF 2 to 45 Mbauds 0 35 1 2 2 3 3 4 5 6 7 8 and AUTO Selectable ON OFF MPEG 2 DVB MP O ML Service list and PIDs ANALOGUE SIGNALS MEASUREMENT LEVEL MEASUREMENT Measurement range Terrestrial TV amp FM bands Satellite TV band Reading Digital Analogue Measurement bandwidth Audible indicator 11 2013 10 dBpV to 120 dByV 3 16 uV to 1 V 30 dBuV to 120 dBuV 31 6 uV to 1 V Auto range reading is displayed on an OSD window Absolute value calibrated in dBuV dBmV or dBm Relative value through an analogue bar on the screen 230 kHz Terrestrial band 4 MHz Satellite band maximum band ripple 1 dB LV audio A tone with pitch proportional to signal strength Page 5 AxPROMAX Accuracy Terrestrial bands Satellite band Overrange indication MEASUREMENTS MODE Terrestrial bands Analogue channels Digital channels Satellite band Analogue channels Digital channels DATALOGGER function Analogue channels Digital channels SAT IF TEST Function ATTENUATION TEST Function SPECTRUM ANALYSER MODE Satellite band Terrestrial bands Measurement bandwidth Terrestrial Satellite Span Terrestrial Satellite Markers Measurements Terrestrial bands Analogue channels Digital channels Satellite band Analogue channels Digital channels USER S MANUAL PRODIG 5 1 5 dB 30 120 dBuV 45 865 MHz 22 C 5 C 2 5 dB 40 100 dBuV 950 2050 MHz 22 C 5 C T Level
76. NC F adapter 1x AD 056 F F DIN F adapter 1x AD 057 F F F F adapter 1x AL 103 External DC charger 1x DC 265 Carrying bag 1x DC 289 Transport belt 1x AA 103 Car lighter charger 1x CA 005 Mains cord OPTIONAL ACCESSORIES DC 229 Transport suitcase DC 266 Protective bag Page 8 11 2013 2 SAFETY RULES A 2 1 General safety rules A Use this equipment connected only to systems with their negative of measurement connected to ground potential gt The AL 103 external DC charger is a Class I equipment for safety reasons plug it to a supply line with the corresponding ground terminal si This equipment can be used in Overvoltage Category installations and Pollution Degree 2 environments External DC charger can be used in Overvoltage Category Il installation and Pollution Degree 1 environments When using some of the following accessories use only the specified ones to ensure safety Rechargeable battery External DC charger Car lighter charger cable Power cord Observe all specified ratings both of supply and measurement Remember that voltages higher than 60 V DC or 30 V AC rms are dangerous X Use this instrument under the specified environmental conditions X When using the power adaptor the negative of measurement is at ground potential Do not obstruct the ventilation system of the instrument sd Use for the signal inputs outputs specially when working with high levels appropriate low radiation cables
77. ONES PRODIG 5 Ajuste del color de fondo de la pantalla Activa el sensor de luminosidad ambiental 5 para el ajuste autom tico del contraste y brillo de la pantalla Opciones Alto contraste para condiciones de baja luminosidad Bajo contraste para condiciones de alta luminosidad y AUTO Selecciona el tipo de se al digital terrestre DVB C o DVB T que detectan las funciones AUTO ID y EXPLORER Nivel m nimo de se al digital a representar Entre 0 0 dBuV y 130 0 dBuV Nivel m nimo de se al anal gica a representar Entre 0 0 dBuV y 130 0 dBuV Nivel minimo de se al digital a representar Define el modo de medida de la relaci n C N como Autom tico o Manual Ruido de Referencia para determinar la frecuencia donde se medir el ruido en el modo analizador de espectro Establece el tiempo m ximo que el equipo dedicar a la identificaci n de un canal desconocido antes de pasar al siguiente S lo en la banda sat lite Selecciona la banda C o la banda Ku para la sinton a de se ales sat lite Activa la funci n de desconexi n autom tica Selecciona el tiempo de desconexi n entre 1 y 120 minutos Selecciona las unidades de medida dBuV dBmV o dBm Selecciona el sentido de desplazamiento horario o antihorario Salida del men de preferencias Tecla n mero 8 para la entrada de datos num ricos P gina 24 11 2013 23 24 25 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX
78. ONES PRODIG 5 AXxPROMAX Para seleccionar la tensi n de alimentaci n de las unidades exteriores pulsar la 2 tecla ssc 11 en el monitor aparecer el men de funciones ALIMENTACI N EXTERIOR mostrando las tensiones seleccionables Girando el selector rotativo 1 seleccionar la tensi n deseada y finalmente pulsarlo para activarla La siguiente tabla muestra las tensiones de alimentaci n seleccionables Banda Tensiones de alimentaci n SAT LITE Exterior 5 V 13V 15V 13 V 22 kHz 18 V 22 kHz TERRESTRE Tabla 3 Tensiones de alimentaci n de la unidad exterior En el modo de alimentaci n Exterior es la unidad de alimentaci n de los amplificadores previos de antena televisi n terrestre o el receptor de TV sat lite dom stico o colectivo el encargado de suministrar la corriente de alimentaci n a las unidades exteriores El indicador DRAIN 3 se iluminar cuando circule corriente hacia la unidad exterior Si se produce cualquier problema por ejemplo un cortocircuito aparecer un mensaje de error en la pantalla ALIMENT CORTOCIRCUITADA se oir la se al ac stica y el equipo pasar a un estado en el que deja de suministrar tensi n El PRODIG 5 EXPLORER no vuelve a su estado de trabajo normal hasta que el problema desaparece durante este tiempo comprueba cada tres segundos la persistencia del problema avisando con una se al ac stica 11 2013 P gina 31 LR PROMAX MANUAL DE INSTRUCCIONES
79. PRODIG 5 EXPLORADOR UNIVERSAL DE TV UNIVERSAL TV EXPLORER EXPLORATEUR UNIVERSEL DE TV Vid PR PROMAX NOTAS SOBRE SEGURIDAD Antes de manipular el equipo leer el manual de instrucciones y muy especialmente el apartado PRESCRIPCIONES DE SEGURIDAD El s mbolo AN sobre el equipo significa CONSULTAR EL MANUAL DE INSTRUCCIONES En este manual puede aparecer tambi n como s mbolo de advertencia o precauci n Recuadros de ADVERTENCIAS Y PRECAUCIONES pueden aparecer a lo largo de este manual para evitar riesgos de accidentes a personas o da os al equipo u otras propiedades SAFETY NOTES Read the user s manual before using the equipment mainly SAFETY RULES paragraph The symbol AN on the equipment means SEE USER S MANUAL In this manual may also appear as a Caution or Warning symbol Warning and Caution statements may appear in this manual to avoid injury hazard or damage to this product or other property REMARQUES A PROPOS DE LA SECURITE Avant de manipuler l appareil lire le manuel d utilisation et plus particuli rement le paragraphe PRESCRIPTIONS DE SECURITE Le symbole A sur l appareil signifie CONSULTER LE MANUEL D UTILISATION Dans ce manuel il peut galement apparaitre comme symbole d avertissement ou de pr caution Des encadr s AVERTISSEMENTS ET PRECAUTIONS peuvent apparaitre dans ce manuel pour viter des risques d accidents affectant des personnes ou des dommages l appareil
80. PROMAX MANUEL D UTILISATION PRODIG 5 5 8 Fonction d Identification Automatique de signaux AUTO ID Le PRODIG 5 EXPLORER permet d identifier automatiquement des signaux de TV conform ment la configuration tablie qui se trouvent pr sents dans le canal ou la fr quence syntonis e Pour activer cette fonction on doit pousser une fois sur la touche 25 Sp cialement utile peut r sulter de combiner ce processus avec la 4 ry surveillance du spectre art 13 de sorte qu apr s avoir situ le marqueur sur les niveaux susceptibles de contenir une mission et en activant ensuite le processus d identification automatique il permette d identifier le signal existant AUTO ID D MARRE ESSAI ANALOGI QUE NIVEAU I NSUFFI SANT 43 9 lt 50 0 dBuV ESSAI DVB T PUI SSANCE OK 59 6 gt 32 0 dBuv ESTI MATI ON LARGEUR CANAL Figure 9 cran d identification automatique de signaux AUTO ID L appareil essayera d examiner s il s agit d un canal analogique ou num rique Si le canal est analogique il d termine le type de standard du signal d tect Si est num rique DVB analyse pour chaque type de modulation QAM QPSK COFDM tous les param tres associ s porteuses 2k 8k symbol rate code rate etc et il d termine les valeurs du signal en test Si la fonction AUTO ID est activ e dans le mode analyseur de spectre le nom du r seau appara tra dans l cran cette donn e est indiqu e aussi l cran dans
81. QUENCE Permet de passer du mode de syntonie canal au mode fr quence En mode canal la s lection de la fr quence de syntonie s ajuste au plan de canaux actif CCIR OIRT etc Touche num ro 0 pour l entr e de donn es num riques 25 IDENTIFICATION AUTOMATIQUE EXPLORATION Active la fonction d identification automatique pulsation courte L appareil essayera d identifier le signal pr sent dans le canal ll examine d abord s il s agit d un canal analogique ou num rique Si le canal est analogique d termine le type de standard du signal d tect S il est num rique analyse pour chaque type de modulation QAM QPSK COFDM tous les param tres associ s porteuses 2k 8k symbol rate code rate etc et d termine les valeurs du signal en test Dans le mode analyseur de spectre il indique l cran le nom du r seau et la position orbitale Seulement dans la bande satellite Active la fonction d exploration de la bande pulsation longue Le mesureur explore toute la bande de fr quences pour identifier les canaux analogiques et num riques pr sents 11 2013 Page 25 AxPROMAX MANUEL D UTILISATION PRODIG 5 Figure 5 Panneau sup rieur 30 RF 6 Entr e du signal RF Niveau maximal 130 dBuV Connecteur universel pour alimentateur F F ou F BNC avec imp dance d entr e de 75 Q ATTENTION AN Utiliser l att nuateur de 10 dB AT 010 pour prot ger l entr e RF 30 quand le niveau du s
82. SATION PRODIG 5 AXPROMAX Pour s lectionner la tension d alimentation des unit s externes pousser la touche ss 11 on verra appara tre sur le moniteur le menu de fonctions intitul ALIMENTATION EXTERNE avec les diff rentes tensions pouvant tre s lectionn es En tournant la mollette 1 s lectionner la tension souhait e et le pousser finalement pour l activer Le tableau ci dessous montre les tensions d alimentation pouvant tre s lectionn es SATELLITE Externe 13 V 22 kHz 18 V 22 kHz TERRESTRE Externe 5 V 13V 15 V 18 V 24 V Tableau 3 Tensions d alimentation au LNB ou unit externe Dans le mode d alimentation Externe c est l unit d alimentation des amplificateurs pr alables a l antenne t l vision terrestre ou le r cepteur de TV satellite individuel ou collectif qui est charg de fournir le courant d alimentation aux unit s ext rieures L indicateur DRAIN 3 s allumera lorsque le courant circulera vers unit externe S il se produit un probl me quelconque par exemple un court circuit on entendra le signal acoustique et il appara tra un message d erreur sur l cran COURT CIRCUIT ALIMENT et l appareil cessera de fournir la tension au LNB Le PRODIG 5 EXPLORER ne reprendra son fonctionnement normal que lorsque le probl me aura disparu pendant ce temps il v rifie aux trois secondes la persistance du probl me en informant avec un ton acoustique 11 2013 Page 31 Ax
83. TER A COLOR SIMBOLO NIVEL DE CARGA VERDE coo 75 100 AMARILLO OE 30 75 a 10 30 lt 10 all Bater a en carga ROJO Tabla 2 Indicadores del nivel de la bater a 3 1 2 1 Carga de la Bater a Para cargar totalmente la bater a alimentar el equipo mediante el alimentador DC externo sin activar la puesta en marcha El tiempo de carga depende del estado en que se encuentre la bater a Si la bater a est descargada el tiempo de carga con el equipo apagado es de unas 5 horas El indicador luminoso CHARGER 4 permanecer encendido Cuando el proceso de carga de la bater a con el equipo apagado finaliza el ventilador se apaga IMPORTANTE Es necesario guardar el equipo con la bater a cargada entre un 30 y un 50 de su capacidad en per odos de no utilizaci n La bater a que incorpora este aparato debe mantenerse en estado de plena carga para obtener el rendimiento esperado Una bater a completamente cargada sufre una autodescarga que depende de la temperatura por ejemplo a 20 C de temperatura ambiental puede llegar a perder un 10 de carga a los 12 meses 3 2 Instalaci n y Puesta en Marcha El medidor de campo PRODIG 5 EXPLORER est dise ado para su utilizaci n como equipo port til por lo que no requiere de instalaci n Pulsando el selector rotativo 1 durante m s de dos segundos se activa la puesta en marcha del equipo y ste se pone en fun
84. TIALITE MARCHE ARRET ISOLATION DOUBLE Protection TYPE II PR CAUTION Risque de secousse lectrique PR CAUTION VOIR MANUEL FUSIBLE 11 2013 MANUEL D UTILISATION PRODIG 5 ZXPROMAX 2 2 Exemples de Cat gories de Surtension Cat Installations de basse tension s par es du secteur Cat Il Installations domestiques mobiles Cat Ill Installations domestiques fixes Cat IV Installations industrielles 11 2013 Page 11 AxPROMAX MANUEL D UTILISATION PRODIG 5 Page 12 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX 3 INSTALLATION 3 1 Alimentation Le PRODIG 5 EXPLORER est un appareil portable aliment par une batterie de Li lon de 7 2 V 11 Ah Un alimentateur CC externe qui permet de relier l appareil au r seau lectrique pour son utilisation et pour la recharge de la batterie est aussi fourni 3 1 1 Fonctionnement avec l alimentateur CC Externe Branchez l alimentateur CC externe a l appareil au travers du connecteur EXT SUPPLY 32 sur le panneau lat ral droit du PRODIG 5 EXPLORER Connectez Palimentateur CC au r seau Poussez ensuite la mollette 1 pendant plus de deux seconds Dans ces conditions le mesureur de niveau est en fonctionnement et les batteries sont recharg es petit a petit Lorsque l appareil est branch au r seau l indicateur lumineux CHARGER 4 demeure allum Cet indicateur change de couleur selon l tat de charge de la batterie TAT DE CHARGE DE LA B
85. TO Choisit le type signal num rique terrestre DVB C ou de DVB T que d tectent les fonctions AUTO ID et EXPLORER Niveau minimal de signal num rique repr senter Entre 0 0 dBmV et 130 0 dBmV Niveau minimal de signal analogique repr senter Entre 0 0 dBmV et 130 0 dBmV Niveau minimal de signal num rique repr senter D finit le mode de mesure du rapport C N comme Auto ou Bruit de R f rence Manuel pour d terminer la fr quence dans laquelle sera mesur le niveau de bruit dans le mode analyseur de spectre Etablit le temps maximal que l appareil utilisera pour l identification d un canal inconnu avant de passer le suivant Seulement dans la bande satellite Choisit la bande C ou de la bande Ku pour la syntonie de signaux satellite Active la fonction de d branchement automatique Choisit le temps de d branchement entre 1 et 120 minutes Choisit les unit s de mesure dBmV dBuV ou dBm Choisit le sens de d placement horaire ou anti horaire Sortie du menu de pr f rences Touche num ro 8 pour l entr e de donn es num riques Page 24 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX 8 A 23 wxyz POINTAGE D ANTENNES Utilit pour le pointage des antennes en bande satellite et terrestre avec balayage plus de rapide et pr sentation de mesures sur une barre graphique de niveau Touche num ro 9 pour l entr e de donn es num riques 0 24 SYNTONIE CANAL FRE
86. UTO ID First it recognises whether the signal is an analogue channel or a digital one If the channel is analogue it determines the television standard of the signal When the signal is digital DVB it analyses for each modulation type QAM QPSK COFDM all the associated parameters such as the modulation system carriers 2k 8k symbol rate code rate etc and determines the value of the signals under test If the AUTO ID function is launched in the spectrum analyser mode the name of the network will appear temporarily on screen it also appears in the measurement display In case of working in the satellite band the orbital position appears as well Whenever the process detects new parameters for a channel or frequency will create a new channel plan containing the detected information NOTE In the case that is desired to explore or identify DVB C signals will be necessary to select previously a DVB C standard as digital signal identifier by means of 22 PREFERENCES menu 5 9 Channel plans The signal automatic identification process as much as the exploration of the frequency spectrum could yield the generation of new customised channel plans relative to the usual work locations of the meter equipment In this way the characterisation of the band will be faster and easier when causing that the equipment only analyses a shorter set of channels Page 32 11 2013 Whenever a new process of exploration is activated the PRODI
87. Video Audio ratio and Carrier Noise ratio Channel power Carrier Noise ratio and Channel identification Level and Carrier Noise ratio Channel power and Carrier Noise ratio Measurements automatic acquisition and storage Level C N and V A ratios Frequency offset MPEG 2 detection power C N MER CBER VBER and noise margin IF distribution network response for satellite band Signal distribution network response for terrestrial band 30 dBuV to 120 dBuV 31 6 pV to 1 V 10 dBuV to 120 dBuV 3 16 pV to 1 V 230 kHz 4 MHz Full span full band 500 200 100 50 32 16 8 MHz selectable Full span full band 500 200 100 50 32 16 MHz selectable 1 with Frequency and level indications Level Channel power Level Channel power 3 Using PkTools software application with a PC Function to be used with RP 250 or RP 050 IF signal simulator 5 Function to be used with RP 250 or RP 080 pilot signals simulator Page 6 11 2013 USER S MANUAL PRODIG 5 MONITOR DISPLAY Monitor Colour system TV standard Spectrum mode Sensibility BASE BAND SIGNAL VIDEO External video input Sensibility Video output SOUND Input Outputs Demodulation De emphasis Subcarrier RS 232C INTERFACE EXTERNAL UNITS POWER SUPPLY Terrestrial and Satellite 22 kHz signal Voltage Frequency Maximum power DiSEqC GENERATOR POWER SUPPLY Internal Batteries Autonomy Recharging time Ex
88. X MANUAL DE INSTRUCCIONES PRODIG 5 ami ESPECTRO TV Permite la conmutaci n entre cualquier modo anterior y el modo Analizador de Espectros y viceversa Tecla n mero 4 para la entrada de datos num ricos 5 de sk BANDA SAT LITE TERRESTRE Permite la conmutaci n entre la banda de frecuencias de TV Sat lite o TV Terrestre Tecla n mero 5 para la entrada de datos num ricos S Indicador que se ilumina cuando el equipo trabaja con las frecuencias y los canales correspondientes a la banda sat lite T Indicador que se ilumina cuando el equipo trabaja con las frecuencias y los canales correspondientes a la banda terrestre fe A E 7 CONFIGURACI N DE MEDIDAS Permite la conmutaci n entre el modo de medidas para TV Digital o TV Anal gica D Indicador que se ilumina cuando el equipo trabaja con se ales digitales A Indicador que se ilumina cuando el equipo trabaja con se ales anal gicas 6 es lt a mno AJUSTE DE IMAGEN Activaci n de los men s de control de VOLUMEN CONTRASTE BRILLO SATURACI N y MATIZ s lo en el sistema de color NTSC Tecla n mero 6 para la entrada de datos num ricos P gina 22 11 2013 21 22 MANUAL DE INSTRUCCIONES PRODIG 5 AXPROMAX 7 DiSEqC pars DISEQC S lo en la banda sat lite Permite ajustar par metros de configuraci n en banda sat lite Tecla n mero 7 para la entrada de datos num ricos 8 tuv UTILIDADES PREFERENCIAS Activa el men de
89. XYZ 4 35554 Figure 4 Clavier principal a D S e TOUCHE TV Permet de visualiser l image de TV correspondant au signal d entr e ainsi que le donn es relatives la r ception du signal de vid o yf y AG EE B Touche num ro 1 pour l entr e de donn es num riques 2 asc ALIMENTATION DES UNIT S EXT RIEURES Permet de s lectionner l alimentation des unit s ext rieures Les valeurs d alimentation peuvent tre External 5 V 13 V 15 V 18 V et 24 V pour la bande terrestre et External 5 V 13 V 15 V 18 V 24 V 13 V 22 kHz et 18 V 22 kHz pour la bande satellite Touche num ro 2 pour l entr e de donn es num riques 3 per MESURES Permet de s lectionner le type de mesure Les types de mesure qu on peut s lectionner d pendent de la bande du standard et du mode d op ration Touche num ro 3 pour l entr e de donn es num riques 11 2013 Page 21 13 14 15 16 17 18 19 20 Z amp PROMAX MANUEL D UTILISATION PRODIG 5 ani SPECTRUM TV Permet de passer du mode de fonctionnement TV au mode Analyseur de Spectre et vice versa Touche num ro 4 pour l entr e de donn es num riques 5 5 INS AT JKL BANDE SATELLITE TERRESTRE Permet la commutation entre la bande de fr quences de TV Satellite ou TV Terrestre Touche num ro 5 pour l entr e de donn es num riques S Indicateur qui
90. a D touche 17 2 S lectionner au moyen de loption Signal du menu de CONFIGURATION DVB C pour la mesure de signaux modul s en QAM DVB T pour la mesure de signaux modul s en COFDM ou DVB S pour la mesure de signaux modul s en QPSK Les marges de fr quence admissibles sont les suivantes Signaux DVB C QAM 45 MHz a 865 MHz Signaux DVB T COFDM 45 MHz a 865 MHz Signaux DVB S QPSK 950 MHz 2150 MHz 3 Introduire les param tres relatifs au signal num rique qui apparaissent dans le menu de CONFIGURATION de la mesure lesquels on a d crit ci avant 4 Choisir l option sortir du menu de CONFIGURATION des mesures 5 14 5 1 Signaux DVB C Apr s avoir tabli les param tres du signal QAM il sera possible de mesurer le 3 BER pousser la touche ser 12 jusqu ce qu apparaisse l cran de mesure du BER Dans le mode de mesure du BER le moniteur montrera un cran comme le suivant Page 52 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX Figure 26 cran de mesure du BER de signaux modul s en QAM On montre la mesure du BER avant la correction d erreurs BER avant FEC Dans un syst me de r ception de signal num rique par cable apr s le d modulateur de signal QAM une m thode de correction d erreurs est appliqu e Reed Solomon voir la figure suivante Il est vident que le taux d erreur la sortie du correcteur est inf rieur le taux d erreur la sortie du d modulateur QAM C est pour c
91. a mollette 1 pour obtenir la liste des services disponibles 11 2013 Page 17 AxPROMAX MANUEL D UTILISATION PRODIG 5 Page 18 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX 5 MODE D EMPLOI AVERTISSEMENT Les fonctions qui sont d crites ensuite pourraient tre modifi es en fonction de mises a jour du software de l appareil effectu es apr s sa fabrication et la publication de ce manuel 5 1 Description des Commandes et des l ments Panneau frontal B u amp El ue le a a D PRODIG 5 UNIVERSAL TV EXPLORER Figure 3 Panneau frontal 1 Mollette Elle poss de de multiples fonctions Mise en marche et arr t de l appareil contr le de syntonie d placement dans les diff rents menus et sous menus qui apparaissent sur le moniteur et validation des diverses options 11 2013 Page 19 2 8 4 5 6 7 8 AxPROMAX MANUEL D UTILISATION PRODIG 5 Pour activer la mise en marche de l appareil maintenir pouss e la mollette pendant plus de deux seconds jusqu l apparition de l cran de pr sentation Pour teindre le mesureur maintenir pouss la mollette jusqu ce qu on d connecte l alimentation Pour modifier la syntonie en tournant la mollette dans le sens des aiguilles d une montre la fr quence augmente alors qu en la tournant dans le sens contraire la fr quence diminue Pour se d placer sur les menus de fonctions en tou
92. a saisie de donn es on offrira l option de stocker l acquisition effectu e ou de faire une nouvelle Page 36 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX TERMI NE POINT DE MESURE PLAN FR QUENCES FREQ MHz M REF kHz N NIVEAU CAN Figure 14 Fin de l acquisition REMARQUE Pour choisir les fonctions Essai Attenuation ou essai Fl SAT ICT il peut tre n cessaire d changer pr alablement entre la bande de fr quences de TV Satellite ou TV Terrestre au moyen de la touche 5 SS a 10 du panneau frontal 5 11 V rification de r seaux de distribution Essai F I SAT Test Attenuation Cette application permet v rifier facilement la r ponse des installations d ICT Infrastructures de T l communications avant que soient op rationnelles les antennes et les dispositifs de t te La proc dure permet d valuer la r ponse en fr quence de tout un r seau de distribution de signaux de TV partir de deux pas NOTE Pour cette application on recommande l utilisation du g n rateur de signaux RP 050 RP 080 ou RP 250 de PROMAX pour lesquels a t sp cialement con u 1 CALIBRAGE Brancher directement le g n rateur au PRODIG 5 EXPLORER au moyen du connecteur adaptateur BNC F Alimenter le RP 050 RP 080 travers EXPLORER pour cela choisir la fonction ALIM EXT voir le chapitre 4 8 Alimentation des Unit s Externes en poussant la 11 2013 Page 37
93. a incorrecte elle aussi 2 Taux Viterbi Rapport Vitesse Aussi connu comme rapport de Viterbi Il d fine le rapport entre le num ro de bits de donn es et les bits r els de transmission la difference correspond au num ro de bits de contr le pour la d tection et r cup ration d erreurs Il permet de s lectionner entre 1 2 2 3 3 4 5 6 et 7 8 3 Vitesse Symboles Vitesse de symbole ll est possible de s lectionner entre la suivante marge de valeurs de 2000 a 45000 kbauds En s lectionnant l option il appara t la valeur actuelle pour la modifier introduire une nouvelle valeur a travers le clavier 11 2013 Page 43 4 5 6 7 AxPROMAX MANUEL D UTILISATION PRODIG 5 NWvD ADCK ASTRA VL Figure 20 cran de configuration de mesure de signaux modul s en QPSK Polarisation Il affecte la r ception de signaux dans la bande SAT satellite Permet de choisir la polarisation du signal entre Vertical Droite vertical et circulaire droite et Horizontal Gauche vertical et circulaire gauche ou bien la d sactiver OFF Bande Sat Choisit la bande Haute ou Basse de fr quences pour la syntonisation des canaux satellite LNB Freq Basse Il d finit la fr quence de Poscillateur local du LNB pour la bande basse LNB Freq Haute Il d finit la fr quence de l oscillateur local du LNB pour la bande haute Page 44 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX REMARQUE IMPORTANTE La syn
94. a interfaz RS 232C para facilitar los procesos de diagn stico ajuste y calibraci n Este equipo debido a su dise o ultra compacto especificaciones t cnicas y bajo coste se sit a como el instrumento de referencia para el instalador z DiSEqc es una marca registrada de EUTELSAT 11 2013 P gina 3 AxPROMAX 1 2 Especificaciones A MANUAL DE INSTRUCCIONES PRODIG 5 CONFIGURACI N PARA MEDIDA DE NIVEL Y POTENCIA SINTON A Modos de sinton a Plan de canales Resoluci n B squeda autom tica Explorer Identificaci n de se ales ENTRADA DE RF Impedancia Conector M xima se al M xima tensi n de entrada DC a 100 Hz 45 MHz a 2150 MHz S ntesis digital de frecuencia Sinton a continua de 45 a 865 MHz y de 950 a 2150 MHz Canal o Frecuencia Fl o directa en banda sat lite Configurable para cada sesi n 45 865 MHz 50 kHz 950 2150 MHz lt 200 kHz span FULL 500 200 100 50 32 16 MHz Nivel umbral seleccionable Selecci n DVB T o DVB C Anal gicas y digitales Autom tica 750 Universal con adaptador BNC o F 130 dBuV 50 V rms alimentado por el cargador AL 103 30 V rms no alimentado por el cargador AL 103 130 dBuV MEDIDA DE SENALES DIGITALES MARGEN DE POTENCIA COFDM QAM QPSK MEDIDAS DVB T COFDM Presentacion DVB C QAM Presentacion DVB S QPSK Presentacion Pagina 4 45 dBuV a 100 dBuV 45 dByV a 110 dBuV 44 dBuV a 114 dBpV Potencia CB
95. al or satellite 4 MWh 2 Press cx 13 key to activate the signals sweeping 3 Press 6 to modify the reference level in the vertical axis A ap 4 Press W 6 to modify span in the horizontal axis STEP 7 Video signal monitoring 5 Is 1 Select the terrestrial frequency band au 14 0 At 2 Tune the channel or frequency 24 that is desired to visualize on screen 3 3 Verify that the equipment receives an appropriate signal level ve 12 1 JA 4 Press e 10 key to visualise the TV image if the channel is digital press w 6 and place the cursor on the Service Identifier field and press the rotary selector 1 to obtain the available list of services 11 2013 Page 17 ZXPROMAX USER S MANUAL PRODIG 5 Page 18 11 2013 5 OPERATING INSTRUCTIONS WARNING The following described functions could be modified based on software updates of the equipment carried out after manufacturing and the publication of this manual 5 1 Description of the Controls and Elements Front panel 1 2 3 US LE ET CEE ME hess 6 7 ABC 8 DEF 9 GHI 0 JKL sz aa MNO PQRS TUV WXYZ t ras PRODIG 5 UNIVERSAL TV EXPLORER Figure 3 Front panel 1 Rotary selector button This has many different functions Equipment power on off tuning control moving between the various on screen menus and sub menus and validation of the different options
96. ales presentes en cada momento El tama o compacto y peso ligero del EXPLORER permiten que sea manejado con una sola mano Utilizando la funda o cinta de transporte suministrada el equipo puede sujetarse al cuerpo a la vez que es protegido de las inclemencias ambientales El protector anti choque proporciona una robustez adicional para los trabajos de campo disponiendo de una maleta r gida de transporte opcional Adem s el equipo ha sido dise ado para impedir la entrada accidental de l quidos El PRODIG 5 est dise ado para integrar medidas que requieren configuraciones de operaci n muy diferentes De este modo incorpora una funci n espec fica para facilitar el apuntamiento de antenas Al activarla el instrumento se configura autom ticamente para ofrecer un barrido del espectro muy r pido y una barra gr fica de alta sensibilidad permite el ajuste fino de los m ximos de se al Adem s incluye un m dulo para la alimentaci n de LNBs y antenas DVB T a 5 V As como comandos para la programaci n de dispositivos DiSEqC 1 2 El EXPLORER permite una actualizaci n sencilla a nuevas versiones de software que ampl en en un futuro las funciones disponibles De esta manera puede incorporar nuevas prestaciones sin coste adicional Como por ejemplo la verificaci n de las redes de distribuci n de se ales sat lite Su utilizaci n en combinaci n con un generador de FI facilita una comprobaci n sencilla de las instalaciones antes de su ent
97. anal gicas representan el nivel de se al correspondiente a la frecuencia o canal sintonizado La barra de la izquierda muestra el valor de pico con una cierta persistencia La barra de la derecha muestra el valor medio filtrado P gina 64 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 ZRPROMAX Figura 39 Utilidad para el apuntamiento de antenas Simult neamente el medidor emite por el altavoz un tono ac stico que var a en funci n del nivel de se al recibida 5 18 Generador de Comandos DiSEqC DiSEqC del Ingl s Digital Satellite Equipment Control es un protocolo de comunicaci n entre el receptor de sat lite y los accesorios de la instalaci n de sat lite conmutadores LNBs etc propuesto por Eutelsat con el fin de estandarizar la diversidad de protocolos de conmutaci n 13 18 V 22 kHz y satisfacer las necesidades de las instalaciones para la recepci n de TV digital Para definir y o enviar una secuencia de comandos DiSEqC pulsar la tecla DiSEqC 21 del panel frontal definir los par metros de configuraci n para la banda sat lite y seleccionar en la funci n SEND uno de los ocho programas predefinidos que realizan funciones b sicas de control de un conmutador universal de dos o cuatro entradas mediante el selector rotativo 1 7 DiSEqC es una marca registrada EUTELSAT 11 2013 P gina 65 LR PROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Cs CATELITE NI EE 0 SATCR FREC ISSUE mie
98. antenna terrestrial television or the satellite TV receiver house hold or community also powers the external units The DRAIN 3 indicator lights when current is flowing to the external unit If any kind of problem occurs e g a short circuit an error message appears on the monitor SUPPLY SHORT the acoustic indicator will be heard and the instrument will cease to supply power The PRODIG 5 EXPLORER does not return to its normal operating state until the problem has been solved during this time it verifies every three seconds the persistence of the problem warning with an acoustic signal 5 8 Automatic signal identification function AUTO ID The PRODIG 5 EXPLORER allows automatically identifying TV signals according to the established configuration which are presents in the channel or tuned frequency In order to activate this function must once press 25 key Specially useful is to combine this process with the spectrum monitoring ani 13 so that after locating the marker on the levels susceptible to contain a transmission and activating later the process of automatic identification in order to identify the present signal 11 2013 Page 31 ZXPROMAX USER S MANUAL PRODIG 5 AUTO 1D FREQ 794 00 MHz STARTING TESTING FOR ANALOG NOT ENOUGH LEVEL 43 5 lt 50 dBuV TESTING DVB T POWER OK 59 3 gt 32 0 dBuV CALCULATING CHANNEL BW Figure 9 Signal automatic identification screen A
99. appears on screen the name of the network and the orbital position only in satellite band Activates the band exploration function long pulsation The meter explores the entire frequency band to identify the analogue and digital channels present 11 2013 Page 25 ZXPROMAX USER S MANUAL PRODIG 5 Figure 5 Top panel view 30 RF RF signal input Maximum level 130 dByV Universal connector for F F or F BNC adapter with input impedance of 75 Q ATTENTION A Use the 10 dB attenuator AT 010 to protect the RF 30 input whenever the input signal level is greater than 130 dB V 1 V or when suspecting of intermodulation problems This accessory allows DC voltages to pass when powering external units as LNB and amplifiers Page 26 11 2013 Ss V7 Ae d N7 Figure 6 Connecting external attenuator on RF input 30 D ATTENTION A Note the importance to protect the RF 30 input signal with an accessory to block the AC voltages used in CATV cables needed to feed the amplifiers and remote mode Figure 7 Lateral panel elements 31 RESET button Enables the user to restart the instrument if there is any irregularity when operating 11 2013 Page 27 AXPROMAX USER S MANUAL PRODIG 5 32 External 12 V power supply input 33 Loudspeaker 34 Fan 35 SCART connector 36 Transport belt hook Figure 8 R
100. artir de la mesure du C N en bande satellite m7 en accordant nouveau le canal en mode de syntonie par fr quence 24 la valeur plus petite possible 5 14 5 2 Signaux DVB T Apr s avoir tabli les param tres du signal COFDM il sera possible de mesurer le BER On pr sente deux mesures Ensuite on montre la mesure du BER avant la correction d erreurs BER avant le FEC CBER DVB T COFDM 5 0E 4 Figure 28 cran de mesure du CBER de signaux modul s en COFDM Dans un syst me de r ception de signal num rique terrestre apr s le d codeur de signal COFDM deux m thodes de correction d erreurs sont appliqu es Il est vident que chaque fois qu un correcteur d erreurs est appliqu au signal num rique le taux d erreur change ce qui fait que si l on mesure le taux d erreur la sortie du d modulateur de COFDM apr s Viterbi et a la sortie du d codeur de Reed Solomon Pon obtient des taux d erreurs diff rents Le PRODIG 5 EXPLORER donne la mesure du BER apr s Viterbi VBER Page 54 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX BER before FEC MER CSI BER after Viterbi COFDM TUNER DEMOD VITERB REED SOLOMON Figura 29 Syst me de r ception COFDM Figure 30 cran de mesure du BER de signaux modul s en COFDM VBER La mesure du BER est pr sent e en valeur absolue en notation scientifique 3 1E 7 signifie 3 1x10 cest a dire 3 1 bits erron s de valeur moye
101. ary activate the Spectral inversion On If the spectral inversion is not correctly selected reception will not be correct all NUD_COAM Pi SIGNAL 0 FRE CH Figure 18 Screen of mesurement configuration QAM signals Page 40 11 2013 5 13 2 DVB T COFDM Digital Channel Configuration D Press the Measurements Configuration 17 key to access to the CONFIGURATION menu and turn the rotary selector 1 to access the COFDM signals parameters which can be defined by user and are described below 1 Carriers Number of carriers It defines the number of modulation carriers between 2k and 8k To modify its value place the marker over the Carriers field by turning the rotary selector and then press it a menu will appear on the screen Turning the rotary selector 1 select the desired value for the Carriers parameter and finally press it again to validate 2 Guard Interval The Guard Interval parameter corresponds to the dead time between symbols its purpose is to permit a correct detection in multi path situations This parameter is defined according to the symbol length 1 4 1 8 1 16 1 32 To modify its value by turning the rotary selector 1 place the marker over the Guard Interval field and then press it a menu with the available values will appear Turning the rotary selector 1 select the desired value and finally press it to validate 3 Channel BW channel bandwidth Enables the channel bandw
102. ated to the transmission modulation and codification Modulation type QPSK 16 QAM 64 QAM Hierarchy Guard Interval Viterbi Code Rate Transmission mode 2k or 8k and Number of the received frame MPEG 2 Correct detection of a MPEG 2 signal 11 2013 Page 55 ZXPROMAX USER S MANUAL PRODIG 5 5 14 5 3 DVB S signals Once determined the parameters of QPSK signal it will be possible to measure BER Following is shown the BER measurement before the error corrections BER before the FEC CBER DVB S QPSK 9 7E 4 Figure 31 Screen of CBER measurement QPSK signals In a digital reception system for satellite signals after the QPSK decoder two different correction methods are applied see following Figure Obviously each time we apply an error corrector to a digital signal the error rate changes therefore if we measure in a digital satellite television system for example the error rate at the output of the QPSK demodulator at the output of the Viterbi decoder and at the output of the Reed Solomon decoder we obtain nothing more than different error rates This is the reason because the BER measurement is provided before FEC after Viterbi VBER BER before FEC BER after Viterbi TUNER EMO VITERBI REED SOLOMON gt Figure 32 Digital reception system via satellite Page 56 11 2013 DVB S QPSK 5 2E 8 The BER measurement is provided in scientific notation i e 2 0 E 3 means 3 2 0x10 t
103. ation mise jour et il le gardera avec le nom du patron original suivi de l extension _0x Voir la figure suivante re CCIR 02 03 04 S01 S02 of 68 69 STD CHANNEL PLAN o L_ CCIR_01 02 04 S03 sof 68 PARAMS NEW CHANNEL PLAN CCIR 02 03 04 S01 S02 so for 68 69 STD CHANNEL PLAN AUTO ID CCIR_01 02 03 04 su fs 69 PARAMS CH04 Figure 10 Processus de g n ration de nouveaux plans de fr quences 11 2013 Page 33 LR PROMAX MANUEL D UTILISATION PRODIG 5 L utilisateur peut supprimer les plans de canaux non souhait s liminer et ins rer des canaux d une autre liste standard au moyen des options d dition qu offre le menu 8 OUTILS 3 22 L EXPLORER permet de changer directement le canal accord appartenant au plan de fr quences actif au moyen des curseurs horizontaux E 6 De cette 0 mani re une fois choisi le champ de syntonie par canal 24 et dans les modes 3 1 d op ration de MESURES 12 et de TV 10 est possible de parcourir cycliquement toute la liste de canaux active REMARQUE Le symbole kd dans le coin sup rieur de l cran indique que l quipement est en train de stocker une information dans la m moire interne Ce symbole appara t pourvu que Putilisateur choisisse une option de registre de donn es par la pulsation de la mollette 1
104. basse pourvu que l option AUTO du menu de PREFERENCES ov 22 soit activ e Si a t activ e l option MANUEL la fr quence de mesure du bruit correspondra la position du curseur repr sent avec couleur verte et lignes discontinues qui apparait dans la pr sentation de le spectre ai 13 Pour modifier cette fr quence pousser la touche de configuration de D mesures 17 acc der au menu de CONFIGURATION En tournant la mollette 1 vous pourrez situer le curseur de NOISE sur la position du marqueur en s lectionnant l option FREQ BRUIT au MARQUEUR voir chapitre 5 15 1 Marqueurs ou introduire directement la valeur de la nouvelle fr quence du bruit a travers de l option FREQ BRUIT H MHz N REF 16 5 dB Figure 24 Curseur NOISE C N MANUEL Dans le cas des mesures de canaux sur la bande de satellite ou de canaux num riques pour que la mesure du rapport C N soit correcte il est indispensable d avoir pr alablement d fini la largeur de bande du canal a l aide de la fonction Largeur Canal v D du menu Configuration des Mesures qui appara t en poussant la touche o 17 Page 50 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX REMARQUE IMPORTANT Pour mesurer correctement le Rapport Porteuse Bruit de canaux num riques il faut syntoniseur le canal dans sa fr quence centrale Dans le cas de la pr sence de canaux num riques adjacents ceux ci peuvent fausser la lecture de la valeu
105. before FEC TUNER REED SOLOMON Figura 27 Sistema de recepci n digital v a cable La medida del BER se presenta en valor absoluto en notaci n cient fica 1 0 E 5 significa 1 0x10 es decir un bit incorrecto de cada 100 000 y mediante una barra anal gica cuanto menor sea su longitud mejor ser la calidad de la se al La representaci n anal gica se presenta sobre una escala logar tmica no lineal Con el fin de tener una referencia sobre la calidad de una imagen se considera que un sistema tiene una calidad aceptable cuando se produce menos de un error no corregible por cada hora de transmisi n A esta frontera se le denomina QEF del ingl s Quasi Error Free y corresponde a una tasa de error aproximada antes de la correcci n de errores de 2 0E 4 BER 2 0x1 o es decir 2 bits incorrectos de cada 10 000 Este valor se ha marcado sobre la barra de la medida del BER y por lo tanto la medida del BER para se ales aceptables debe encontrarse a la izquierda de esta marca Debajo de la barra anal gica de medida del BER se presenta la frecuencia o canal de sinton a y la desviaci n de frecuencia en kHz respecto de la frecuencia de sinton a que optimiza el BER por ejemplo 800 00 MHz 1 2 kHz Esta desviaci n debe ajustarse especialmente a partir de la medida del C N en banda sat lite mm resintonizando el canal en modo de sinton a por frecuencia 24 al valor m s bajo posible 11 2013 P gina 53
106. bilitar Pilotos el dispositivo SatCR situado en la cabecera emite un piloto de nivel constante para cada frecuencia de bajada slot Esta funci n facilita la comprobaci n e identificaci n de los diferentes canales sat lite disponibles en la instalaci n Esta tecnolog a SatCR est siendo desarrollada a nivel de pruebas en diversos pa ses 5 20 Utilizaci n del teclado alfanum rico Para introducir datos num ricos o texto se dispone de un teclado alfanum rico Muchas teclas incorporan un n mero y varias letras al estilo de los teclados telef nicos 1 Introducci n de datos num ricos por ejemplo una frecuencia de sinton a Pulsar la tecla correspondiente al d gito que se desee introducir del O al 9 Al pulsar r 5 A la tecla del punto decimal 17 se introduce el car cter punto y a continuaci n el equipo permite introducir dos d gitos m s Para introducir un n mero negativo 0 primero pulsar la tecla 24 hasta que aparezca el signo 11 2013 P gina 67 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Nota lt Para borrar un d gito desplazarse con las teclas flechas horizontales del cursor ap 6 y posicionarlo detr s del d gito que se desee borrar A continuaci n D mantener pulsada la tecla 17 hasta que desaparezca el digito en la pantalla Repetir la operaci n por cada d gito adicional a eliminar Introducci n de datos alfanum ricos por ejemplo el nombre de una nueva
107. ble of Services SDT Service Description Table acquisition is completed is possible to accede to the list of services contained in the Table For it place the field selector by means of the vertical cursors e 6 on the field of the active service e g Veo TV in the following figure and later press the rotary selector 1 The DIGITAL SERVICES menu will appear then with the services available in the digital Multiplex Move the vertical cursors press it to select the service to visualise on screen OSD ON CHANNEL CCIR DVB T VISTA TV NETW Vis VISTA TV 6 or turn the rotary selector 1 and DTV 1433 PID 101 PID 10 MP ML 120x576i 3 50 Hz bmponent ID 100 IID 12289 VI DEO AUDI O 7 AMI D Mre E 192 kbit s MPEG 1 L 2 Figure 38 Digital channel monitoring Digital services Also is possible to change the active service directly acting through the horizontal cursors 6 once has selected the field of the service from information window of the currently tuned channel 5 17 Antenna Alignment Function It allows executing the function Antenna Alignment to align antennas using a faster sweep without display of numerical measures The display appears divided in two parts the left one shows the spectrum of the signals detected in the band and on the right two analogue bars represents the level of signal corresponding to the tuned frequency or channel The left bar shows the p
108. cessoires de l installation de satellite commutateurs LNB etc propos par Eutelsat dans le but de standardiser la diversit de protocoles de commutation 13 18 V 22 kHz et de r pondre aux besoins des installations pour la r ception de TV num rique Pour d finir et ou envoyer une s quence DiSEqC pousser la touche DiSEqC 21 du panneau frontal d finir les param tres de configuration pour la bande satellite et choisir dans la fonction SEND un des huit programmes pr d finis qui effectuent des fonctions l mentaires de contr le d un commutateur universel de deux ou quatre entr es au moyen de la mollette 1 CATEIL I TIE i SATCR 20 AL M 7 NIVEAU BuV MHz M C N Figure 40 Ecran des commandes DiSEqC Chaque fois qu on envoie un programme DiSEqC on envoie aussi les commandes qui correspondent l tat de l quipement par rapport a la polarisation Horizontale ou Verticale et la bande Haute ou Basse Ceci permet d assurer que l tat de l installation est celle indiqu e par l appareil 7 DiSEqc est une marque d pos e EUTELSAT 11 2013 Page 65 lt _ LL LR PROMAX MANUEL D UTILISATION PRODIG 5 5 19 Fonction SATCR Au moyen de la fonction SATCR est possible de contr ler les dispositifs d une installation de TV satellite qui soient compatibles avec la technologie SatCR de l Anglais Satellite Channel Router laquelle permet de concentrer les multiple
109. cionamiento en modo autodesconexi n es decir transcurridos un tiempo determinado sin haber actuado sobre ning n control el equipo se desconectar autom ticamente Cuando el equipo est en marcha tambi n es posible seleccionar el modo de Apagado Autom tico mediante el men Preferencias 22 y programar el tiempo de espera hasta la desconexi n autom tica P gina 14 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 LR PROMAX 4 GUIA R PIDA DE UTILIZACI N PASO 1 Carga de la bater a 1 Conectar el alimentador DC externo al equipo a trav s del conector 32 situado en el panel lateral derecho 2 Conectar el alimentador DC a la red Cuando el equipo est conectado a la red el indicador luminoso CHARGER 4 permanece encendido CHARGER X DC IN oh ane sui Ie tu Figura 1 Carga de la bater a PASO 2 Puesta en marcha y conexi n de se ales 1 Mantener pulsado el selector rotativo 1 hasta que arranque el equipo 2 Conectar la fuente de se al RF en el conector de entrada 30 RF SOURCE Len Figura 2 Puesta en marcha y conexi n de se ales 11 2013 P gina 15 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 PASO 3 Para hacer una exploraci n completa de la banda de canales 5 Ss 1 Seleccionar la banda de frecuencias de exploraci n al 14 terrestre o sat lite 2 Activar el proceso de exploraci n manteniendo pulsada la tecla 25 1 e
110. contr le automatique de fr quence du syst me peut identifier et suivre une transmission num rique TDT mais ses param tres ne peuvent pas tre obtenus Pour cause une situation transitoire pr c dente l identification des TPS Transmission Parameter Signalling ou bien une transmission de TDT avec un rapport C N insuffisant TPS in lock Les TPS Transmission Parameter Signalling ont t d cod s Les TPS sont des porteuses 17 dans le syst me 2k et 68 dans le syst me 8k modul es en DBPSK contenant information li e a la transmission a la modulation et a la codification Type de modulation QPSK 16 QAM 64 QAM Hi rarchie Intervalle de Garde Viterbi Code Rate Mode de Transmission 2k ou 8k et num ro de la trame re ue MPEG 2 D tection correcte d un signal MPEG 2 5 14 5 3 Signaux DVB S Apr s avoir tabli les param tres du signal QPSK il sera possible de mesurer le BER Ensuite on pr sente la mesure du BER avant la correction d erreurs BER avant le FEC CBER DVB S QPSK 9 7E 4 Figure 31 cran de mesure du CBER de signaux modul s en QPSK Page 56 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX Dans un syst me de r ception de signal num rique par satellite apr s le d codeur de signal QPSK deux m thodes de correction d erreurs sont appliqu es voir figure suivante Il est vident que chaque fois qu un correcteur d erreurs est appliqu au signal num rique le taux d erreur chan
111. de TV seleccionado Banda terrestre portadora digital Ambas medidas se realizan con un detector de valor medio 230 kHz BW y las misma correcciones se introducen en ambas correcciones de ancho de banda Banda sat lite portadora anal gica El nivel de portadora se mide mediante un detector de cuasi pico 4 MHz BW El nivel de ruido se mide mediante un detector de valor medio 230 kHz y se corrige para referirlo al ancho de banda del canal P gina 48 eon MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX D Banda sat lite portadora digital Equivalente al caso B pero ahora utilizando un filtro de medida de 4 MHz Al seleccionar el modo de medida Portadora Ruido en el monitor aparece la siguiente informaci n TERRESTRIAL 40 1 dB Figura 23 Medida de la relaci n portadora ruido C N Adem s de la relaci n entre la portadora de v deo y el nivel de ruido C N 40 1 dB en el ejemplo de la figura anterior se muestra la frecuencia o el canal de acuerdo con el modo de sinton a seleccionado el nivel de la portadora de v deo y la relaci n 4 F AA video audio Al representar el espectro pulsando la tecla em 13 el cursor de NOISE se posiciona autom ticamente a un lado de la portadora sintonizada Es decir el cursor indicar el punto donde el valor del ruido es m s bajo siempre que est 8 seleccionada la opci n AUTO del men de PREFERENCIAS 3 22 Si ha sido activada la opci n MANU
112. decir las marcas de la barra se corresponden con el exponente de la medida Con el fin de tener una referencia sobre la calidad de una imagen se considera que un sistema tiene una calidad aceptable cuando se produce menos de un error no corregible por cada hora de transmisi n A esta frontera se le denomina QEF del ingl s Quasi Error Free casi libre de errores y corresponde a una tasa de error despu s de 4 Viterbi de 2 0E 4 BER 2 0x10 es decir 2 bits err neos cada 10 000 Este valor se ha se alado sobre la barra de la medida del BER despu s de Viterbi Por lo tanto la medida del BER para se ales aceptables debe encontrarse a la izquierda de esta marca Finalmente se muestra una l nea de estado con informaci n respecto a la se al detectada Los posibles mensajes que pueden aparecer y su significado se muestra en la siguiente lista Los mensajes se presentan por orden de menor a mayor cumplimiento de los requerimientos del est ndar MPEG 2 Se al no detectada No se ha detectado ninguna se al Timing recovered Tan s lo es posible recuperar el tiempo de s mbolo 11 2013 P gina 55 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 AFC in lock El control autom tico de frecuencia del sistema puede identificar y seguir una transmisi n digital TDT de la cual no se pueden obtener sus par metros Puede tratarse de una situaci n transitoria previa a la identificaci n de los TPS Transmission Parameter Signalling o bien
113. dora de v deo En el modo de medida de se ales anal gicas el monitor del PRODIG 5 EXPLORER puede actuar como un indicador anal gico de nivel representando la se al presente en la entrada 3 Para cambiar el modo de medida pulsar la tecla v 12 aparecer una pantalla como la siguiente PS TERRESTRE 78 2 dBuV Figura 21 Medida del nivel de se al anal gica en banda terrestre P gina 46 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX Girando el selector rotativo 1 se cambia el canal frecuencia de sinton a Pulsar 3 la tecla oe 12 para escoger el tipo de medida que se desee visualizar en el monitor Los tipos de medidas disponibles son NIVEL Indicaci n de nivel en la parte superior de la pantalla barra anal gica C N Medida de la relaci n portadora ruido V A Medida de la relaci n v deo audio PRECAUCI N Cuando en la entrada de RF se disponga de un n mero importante de portadoras con un nivel elevado el circuito de sinton a puede quedar fuera de control dando como resultado lecturas incorrectas de nivel Para poder determinar el nivel equivalente de un grupo de portadoras de niveles semejantes a la entrada de RF puede utilizarse la expresi n L L 10log N Lg nivel total equivalente L nivel medio del grupo de portadoras N n mero de portadoras presentes As si tenemos 10 portadoras con un nivel alrededor de 90 dBuV su nivel total equivalente ser 90 dBuV 10
114. e du MER pour signaux DVB T modul s en COFDM Page 58 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX En premier lieu on trouvera la mesure du rapport d erreur de modulation MER Ensuite apparait la mesure de la Marge de Bruit MR dans la figure pr c dente est de 8 4 dB Ca repr sente une marge de s curit a partir le MER mesur e en rapport de la d gradation du signal avant d arriver la valeur QEF Quasi Error Free limite Les porteuses analogiques et num riques sont tr s diff rentes en termes de contenu du signal et de distribution de la puissance dans le canal Par cons quent elles doivent tre mesur es diff remment Le rapport d erreur de modulation MER utilis dans les systemes num riques est analogue a la mesure du rapport signal bruit S N dans les porteuses analogiques Le MER repr sente la relation entre la puissance moyenne du signal DVB et la puissance moyenne du bruit pr sent dans la constellation des signaux Par exemple les d modulateurs QAM 64 requi rent un MER sup rieur a 23 dB pour fonctionner Il est donc pr f rable de disposer d une marge d au moins 3 a 4 dB pour compenser de possibles d gradations du syst me alors que les d modulateurs QAM 256 requi rent un MER sup rieur a 28 dB avec des marges d au moins 3 dB Habituellement la valeur maximum de MER visualisable dans des analyseurs portables est d environ 34 dB Derni rement il appara t une ligne d tat qui pr sente d
115. e medida En el caso de que el equipo trabaje en banda sat lite mostrar la posici n orbital Siempre que el proceso detecte nuevos par metros para un canal o frecuencia crear una nueva lista de canales conteniendo la informaci n detectada P gina 32 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX NOTA En el caso que se desee identificar se ales DVB C es necesario acceder 8 previamente al men de PREFERENCIAS x 22 y seleccionar como Identificador de se ales digitales terrestres el est ndar DVB C 5 9 Listas de canales Tanto el proceso de identificaci n autom tica de se ales como el de exploraci n del espectro de frecuencias pueden dar como resultado la creaci n de nuevas listas de canales personalizadas y relativas a la ubicaci n habitual de trabajo del equipo de medida De esta forma la caracterizaci n de la banda resultar m s gil y sencilla al hacer que el equipo s lo analice un conjunto m s reducido de canales Siempre que se activa un nuevo proceso de exploraci n el PRODIG 5 analiza todos los canales presentes en la lista de canales activa la cual act a como lista patr n especificada mediante la opci n CANALIZACI N del men de configuraci n de D la medida CONFIGURACI N 17 Si durante el proceso de exploraci n o de identificaci n autom tica el EXPLORER detecta nuevos par metros para alg n canal o frecuencia generar una nueva lista con la informaci n actualizada y
116. e visualiser l cran 11 2013 Page 63 AxPROMAX MANUEL D UTILISATION PRODIG 5 DTV CLAIR PID 101 PID 103 MP ML 120x576i 3 50 Hz Pmponent ID RNIY gt PILI kbit s MPEG 1 L 2 Figure 38 Visualisation d un canal num rique Services disponibles C est aussi possible de changer le service actif en agissant directement sur les curseurs horizontaux 6 une fois qu on aura choisi le champ du service dans la fen tre d information du canal syntonis 5 17 Fonction Pointage d Antennes Il permet de choisir la fonction Pointage d Antennes que fournit le processus de pointage au moyen d un balayage plus rapide sans pr sentation de mesures num riques L cran est divis en deux parties dans la partie gauche montre le spectre des signaux pr sents dans la bande et dans la droite deux barres analogiques repr sentent le niveau de signal correspondant a la fr quence ou le canal accord La barre a gauche montre la valeur de pic avec une certaine persistance La barre a droite montre la valeur moyenne filtr e Figure 39 Outil pour le pointage d antennes Page 64 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX Simultan ment l appareil met par le haut parleur un ton acoustique qui varie selon le niveau de signal recu 5 18 G n rateur d Instructions DiSEqC DiSEqC de Panglais Digital Satellite Equipment ControP est un protocole de communication entre le r cepteur de satellite et les ac
117. eak value with a certain persistence The right bar shows a filtered average value 11 2013 Page 63 ZRPROMAX USER S MANUAL PRODIG 5 Figure 39 Utility for antenna alignment Simultaneously the instrument emits by means of the loudspeaker an acoustic tone which varies according to the level of received signal 5 18 DiSEqC Command Generator DiSEqC Digital Satellite Equipment Control is a communication protocol between the satellite receiver and the accessories of the installation switches LNBs etc proposed by Eutelsat with the aim to standardize the diversity of switching protocols 13 18 V 22 kHz and to satisfy the demands of the digital TV installations In order to define and or to send a sequence of DiSEqC commands press the DiSEqC key 21 on frontal panel It allows to define the satellite band configuration parameters and select through SEND function one of the eight predefined programs which execute basic functions to control an universal switch with two or four inputs by means of the rotary selector 1 7 pisEqc is a trademark of EUTELSAT Page 64 11 2013 all SATELLITE LE 0 SATCR 20 FRE UB uV DL Ku 0 0 MHz C N 6 dB CH Figure 40 DiSEqC command screen Whenever a DiSEqC program is sent the commands that correspond to the equipment status in relation to the Horizontal or Vertical polarization and High or Low frequency band are also sent This allows assurin
118. ear panel view 37 RS 232C Connector For maintenance and calibration processes 5 2 Adjustment of Volume and Monitor Parameters 6 o 1 Repeatedly pressing the mno 3 key sequentially activates the VOLUME CONTRAST BRIGHTNESS SATURATION and HUE control menus this last only for NTSC colour system On activation of a menu for a specific parameter the screen displays a horizontal bar whose length is proportional to the parameter level to modify this value simply turn the rotary selector 1 To exit the menu and validate the new value press the rotary selector 1 Page 28 11 2013 5 3 Selecting the Operation Mode TV Spectrum Analyser Measurements The PRODIG 5 EXPLORER has three basic operation modes TV Spectrum Analyser and Measurements To switch from TV operation mode to the Spectrum 4 Analyser press em 13 key To switch to the Measurements mode press ver 12 key In the TV operation mode the demodulated television signal is shown on screen this is the default operation mode various functions can be selected as shown in the following paragraphs In the Spectrum Analyser operation mode the screen displays the spectrum of the active band terrestrial or satellite The span and the reference level In the Measurement mode the screen shows the available measurements according to the type of signal selected 5 4 Channel Tuning Frequency Tuning 0 ut Pressing 24 key the EXPLORER switches from
119. easurement mode the screen displays the following information TERRESTRIAL 40 1 dB 20 30 40 MA LEVEL C N V A Figure 23 Carrier to noise ratio measurement C N Page 48 11 2013 As well as the video carrier noise level ratio C N 40 1 dB in previous figure the frequency or channel depending on the tuning mode selected and the level of the video carrier and video audio ratio are also shown When representing the spectrum by means of pressing ai 13 key the NOISE cursor is automatically positioned to a side of the carrier tuned That is the cursor will indicate the point where the value of the noise is lower whenever the C N AUTO option is selected from the PREFERENCES 22 rv menu If the C N MANUAL option has been activated the frequency where noise level will be measured will correspond to the position of the vertical discontinuous green coloured cursor that appears in the spectrum graph em 13 fw D In order to modify this frequency press the measurement configuration 17 key to accede to the CONFIGURATION menu By turning the rotary selector 1 locate the NOISE cursor on the position of the marker using NOISE FREQ TO MARKER option see section 5 15 1 Markers or directly enter the value of the new noise frequency by means of NOISE FREQ option 11 2013 Page 49 ZRPROMAX USER S MANUAL PRODIG 5 TA A IN GTR 650 001 a AN REF 16 5 dB Figure 24 NOISE cursor C N
120. ed to explore or identify DVB C signals will be necessary to select previously DVB C standard as digital signal identifier by means of tuv 22 PREFERENCES menu 5 13 Measurements configuration With the aim of taking the measurements of all types of signals some times could be necessary that user enters parameters relative to particular characteristics of these signals whether an automatic detection has not been possible or these parameters differ from the standard corresponding ones 11 2013 Page 39 ZXPROMAX USER S MANUAL PRODIG 5 a z A Press the Measurements Configuration 17 key to access to the CONFIGURATION menu and turn the rotary selector 1 to access to parameters which are modifiable by the user 5 13 1 DVB C QAM Digital Channel Configuration D Press the Measurements Configuration 117 key to access to the CONFIGURATION menu and turn the rotary selector 1 to access the QAM signals parameters which can be defined by user and are described below 1 Modulation lt defines the modulation type When selecting this function and pressing the rotary selector 1 a multiple choice menu will appear on the screen this menu permits to choose one of the following modulations 16 32 64 128 and 256 2 Symbol Rate When selecting this function and pressing the rotary selector 1 a multiple choice menu will appear on the screen this menu permits to choose the symbol rate 3 Spectral inversion If necess
121. ela que cet cran proportionne la mesure du BER avant la correction d erreurs BER before FEC REED SOLOMON Figure 27 Syst me de r ception num rique par c ble La mesure du BER est pr sent e en valeur absolue en notation scientifique 1 0 E 5 signifie 1 0 x10 c est dire un bit incorrect pour chaque 100 000 et l aide d une barre analogique plus sa longueur est petite meilleure sera la qualit du signal La repr sentation analogique est pr sent e sur une chelle logarithmique pas lin aire Afin d avoir une r f rence sur la qualit d une image l on consid re qu un syst me a une qualit acceptable lorsqu il se produit moins d une erreur non corrigible pour chaque heure de transmission L on appelle cette fronti re QEF de l anglais Quasi Error Free et cela correspond a un taux d erreur avant FEC de 2 0E 4 BER 2 0x10 c est dire 2 bits incorrects pour chaque 10 000 Cette valeur a t marqu e sur la barre de la mesure du BER et c est pour cela que la mesure du BER pour des signaux acceptables doit se trouver sur la gauche de cette marque 11 2013 Page 53 LR PROMAX MANUEL D UTILISATION PRODIG 5 Au bas de la barre analogique de mesure du BER on montre la fr quence ou canal de syntonie et la d viation de fr quence en kHz par rapport la fr quence de syntonie qui optimise le BER par exemple Freq 800 000 MHz 1 2 kHz Cette d viation doit s adapter sp cialement a p
122. en color rojo indica la frecuencia central o frecuencia de sinton a que puede desplazarse mediante el giro del 0 selector rotativo 1 tanto en el modo de sinton a por canal como por frecuencia 24 Al monitorizar el espectro de se ales digitales aparecen tambi n dos marcadores adicionales en color blanco que indican el ancho de banda del canal digital ver la figura anterior 5 16 Visualizaci n de la se al de v deo 1 Al pulsar la tecla 2 desde cualquier modo de operaci n el PRODIG 5 EXPLORER accede al modo TV y demodula en la pantalla la se al de v deo sintonizada En el monitor aparecer la imagen de TV con una ventana sobre la parte inferior de la imagen durante cinco segundos mostrando en el caso que la se al sea anal gica el n mero de canal la frecuencia la canalizaci n activa el sistema de color y el est ndar de TV 11 2013 P gina 61 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 DIV LIBRE VPID API D MP ML 720x576i 4 3 50 Hz Component Bibs 00 NID 1 9 kbit s MPEG 2 kbit s MPEG 1 L 2 pes Figura 36 Visualizaci n de un canal digital Si la se al es digital se muestran durante cinco segundos aproximadamente los siguientes par metros n mero de canal frecuencia canalizaci n activa tipo de se al DVB nombre del servicio identificador del servicio SID nombre de red identificador de red NID identificador de programa de v deo VPID identificador de
123. entador para autom vil 1x CA 005 Cable alimentador a la red ACCESORIOS OPCIONALES DC 229 Maleta de transporte DC 266 Estuche protector P gina 8 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX 2 PRESCRIPCIONES DE SEGURIDAD A 2 1 Generales Utilizar el equipo solamente en sistemas con el negativo de medida conectado al potencial de tierra El alimentador DC externo AL 103 es un equipo de clase l por razones de seguridad debe conectarse a l neas de suministro con la correspondiente toma de tierra Este equipo puede ser utilizado en instalaciones con Categor a de Sobretensi n y ambientes con Grado de Poluci n 2 Alimentador externo Categoria de Sobretensi n II Grado de Poluci n 1 Al emplear cualquiera de los siguientes accesorios debe hacerse s lo con los tipos especificados a fin de preservar la seguridad Bater a recargable Alimentador DC externo Cable alimentador para autom vil Cable de red Tener siempre en cuenta los m rgenes especificados tanto para la alimentaci n como para la medida Recuerde que las tensiones superiores a 60 V DC o 30 V AC rms son potencialmente peligrosas Observar en todo momento las condiciones ambientales m ximas especificadas para el aparato Al utilizar el alimentador DC externo el negativo de medida se halla al potencial de tierra No obstruir el sistema de ventilaci n del equipo Utilizar para las entradas salidas de se al especialmente al manejar nivel
124. entes de distribuci n o en los equipos de recepci n El PRODIG 5 ha sido dise ado para satisfacer todas las necesidades de medida durante la transici n de las transmisiones anal gicas a las digitales en sistemas terrestres sat lites y por cable Permitiendo realizar medidas de se ales tanto anal gicas como digitales Al activar la funci n de identificaci n autom tica pulsando una sola tecla el equipo trata de identificar la se al bajo prueba Primero averigua si se trata de un canal anal gico o digital Si el canal es anal gico determina el tipo de est ndar de la se al detectada Si es digital DVB analiza para cada tipo de modulaci n QAM QPSK COFDM todos los par metros asociados portadoras 2k 8k symbol rate code rate etc y determina los valores en la se al bajo prueba El PRODIG 5 incluye los principales est ndares de TV M N B G I D K y L adaptando adem s de los par metros propios del est ndar el sistema autom tico de correcciones para obtener en todos los casos una medida precisa del nivel de se al de entrada Acepta cualquier sistema de televisi n PAL SECAM y NTSC y permite trabajar directamente con se ales de TV digital descodific ndolas para visualizar la imagen de televisi n y para las cuales proporciona directamente la medida de potencia de la relaci n portadora a ruido C N de la tasa de error de la se al digital BER y de la relaci n de error de modulaci n MER tanto para se
125. entra una portadora con un nivel de se al superior al nivel de b squeda El nivel umbral de b squeda se define mediante la opci n Min Ter Nivel para canales anal gicos Min Ter Potencia y Min Sat Potencia para canales digitales del men de PREFERENCIAS 5 6 Selecci n de la configuraci n de medida se al Anal gica Digital La realizaci n de la medida de las caracter sticas de un canal depende en primer lugar del tipo de modulaci n anal gica o digital al Mediante la tecla 20 es posible conmutar de se ales anal gicas a digitales D y viceversa Pulsar la tecla 20 para que aparezca el menu de CONFIGURACI N de la medida y luego seleccionar la opci n Se al girando y pulsando el selector rotativo 1 La opci n Se al permite establecer el tipo de se al que se desea medir Al pasar de un modo al otro el PRODIG 5 EXPLORER activa la ltima configuraci n de medida utilizada para ese tipo de modulaci n 5 7 Alimentaci n de las Unidades Exteriores Mediante el PRODIG 5 EXPLORER es posible suministrar la tensi n necesaria para alimentar las unidades exteriores amplificadores previos de antena en el caso de televisi n terrestre LNB s en el caso de televisi n sat lite o simuladores de Fl A Niveles m ximos de entrada DC a 100 Hz 50 V rms alimentado por el alimentador AL 103 30 V rms no alimentado por el alimentador AL 103 45 MHz a 2150 MHz 130 dBuV P gina 30 11 2013 MANUAL DE INSTRUCCI
126. environ le niveau quivalent sera 90 dBuV 10 log 10 100 dBuV remarquer que dans ce cas il peut appara tre outre une perte d accord par une surcharge de l entr e RF d autres effets tels qu une saturation du syntonisateur et g n ration de produits d intermodulation masquant la visualisation du spectre 5 14 2 TV analogique Mesure du Rapport Vid o Audio V A Dans le mode de mesure Vid o Audio l information ci dessous appara tra sur le moniteur Figure 22 Mesure du rapport Vid o Audio En plus du rapport entre les niveaux de la porteuse de vid o et la porteuse d audio 16 2 dB dans l exemple de la figure pr c dente la fr quence ou le canal sera pr sent conform ment au mode de syntonie s lectionn ainsi que le niveau de la porteuse de vid o et le rapport Porteuse Bruit Page 48 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX 5 14 3 TV analogique num rique Mesure du Rapport Porteuse Bruit C N Le PRODIG 5 EXPLORER effectue la mesure du rapport C N de quatre mani res diff rentes conform ment au type de porteuse et de bande en cours d utilisation A Bande terrestre porteuse analogique Le niveau de porteuse est mesur l aide d un d tecteur de cr te 230 kHz BW Le niveau de bruit est mesur l aide d un d tecteur de valeur moyenne et est corrig pour faire r f rence la largeur de bande quivalente du canal conform ment la d finition du standard
127. es altos cables apropiados de bajo nivel de radiaci n Seguir estrictamente las recomendaciones de limpieza que se describen en el apartado Mantenimiento 11 2013 P gina 9 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Simbolos relacionados con la seguridad P gina 10 I gt gt HMo 4 4 CORRIENTE CONTINUA CORRIENTE ALTERNA ALTERNA Y CONTINUA TERMINAL DE TIERRA TERMINAL DE PROTECCI N TERMINAL A CARCASA EQUIPOTENCIALIDAD MARCHA PARO DOBLE AISLAMIENTO Protecci n CLASE ll PRECAUCI N Riesgo de choque el ctrico PRECAUCI N VER MANUAL FUSIBLE 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXPROMAX 2 2 Ejemplos Descriptivos de las Categor as de Sobretensi n Cat Instalaciones de baja tensi n separadas de la red Cat Il Instalaciones dom sticas m viles Cat Ill Instalaciones dom sticas fijas Cat IV Instalaciones industriales 11 2013 Pagina 11 ZXPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Pagina 12 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX 3 INSTALACI N 3 1 Alimentaci n El PRODIG 5 EXPLORER es un equipo port til alimentado a trav s de una bater a de Li lon de 7 2 V 11 Ah Se suministra tambi n un alimentador DC externo que permite conectar el equipo a la red el ctrica para su operaci n y carga de la bater a 3 1 1 Funcionamiento mediante alimentador DC Externo Conectar el alimentador DC externo al equipo a trav s del conector EXT SUPP
128. es arrive with non correctable errors It is not possible to quantify the BER MPEG 2 Correct detection of a MPEG 2 signal 5 14 6 Digital TV Measuring MER Once determined the suitable parameters for COFDM QAM or QPSK signal reception it will be possible to measure MER press se 12 key until it appears the MER measurement screen DVB T COFDM MER 19 5dB ms A A 10 40 dB dB i Figure 34 MER measurement screen for DVB T COFDM signals First of all you will see the modulation error ratio measurement MER Following it appears the Noise Margin NM measurement in the figure value 8 4 dB It indicates a safety available margin according to the MER level measured that allows signal degradation until arriving to the QEF Quasi Error Free limit value Analogue and digital carriers are very different in terms of signal contents and power distribution over the channel They therefore need to be measured differently The modulation error ratio MER used in digital systems is similar to the Signal Noise S N ratio in analogue systems Page 58 11 2013 MER represents the relation between the average power of DVB signal and the average power of noise present in the constellation of the signals By example QAM 64 demodulators require a MER greater than 23 dB to work Though it is preferable to have at least a 3 or 4 dB margin to compensate for any possible degradation of the system While QAM 256 demod
129. es de transmisi n la diferencia corresponde al n mero de bits de control para la detecci n y recuperaci n de errores Permite elegir entre 1 2 2 3 3 4 5 6 y 7 8 3 Symbol Rate Velocidad de s mbolo Es posible elegir entre el siguiente margen de valores de 2000 a 45000 kbauds Al seleccionar la opci n se muestra el valor actual para modificarlo introducir un nuevo valor a trav s del teclado cuando aparezca el s mbolo de introducci n de datos in Vi gt QODSK CANALI ZACI ON ASTRA VL Figura 20 Pantalla de configuraci n de medida de se ales moduladas en QPSK 4 Polarizacion Afecta a la recepci n de se ales en la banda SAT sat lite Permite seleccionar la polarizaci n de la se al entre Vertical Derecha vertical y circular a derechas y Horizontal Izquierda horizontal y circular a izquierdas o bien desactivarla OFF 11 2013 P gina 43 ZXPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 5 Banda Sat Selecciona la banda Alta o Baja de frecuencias para la sintonizaci n de los canales sat lite 6 Osc LNB Bajo Define la frecuencia del oscilador local del LNB para la banda baja 7 Osc LNB Alto Define la frecuencia del oscilador local del LNB para la banda alta NOTA IMPORTANTE La sinton a de canales digitales DVB puede requerir un proceso de ajuste Se recomienda seguir el siguiente procedimiento 4 Jul Desde el modo analizador de espectro x 13 sintonizar el canal en su frecuencia
130. es et num riques pr sents en accord avec la configuration tablie dans la bande de syntonie Pour activer la fonction on doit maintenir pouss e la touche 25 jusqu ce qu apparaisse l cran de PEXPLORER EXPLORER V RI FI ANT LE PLAN PROMAX 0 25 50 75 100 66 DVB T OK 67 NON IDENTIFI 68 ANALOGI QUE PAL BG 69 AUCUN SIGNAL TROUVE 12 101 EXPLORATION COMPLETEE GARDER Figure 17 Ecran d exploration de spectre EXPLORER Pourvu que le processus d tecte de nouveaux param tres pour un certain canal il cr era un nouveau plan de canaux en contenant l information d tect e NOTE Dans le cas qui on souhaite explorer des signaux ne est n cessaire d acc der pr alablement au menu de PREFERENCES ruv 22 et de choisir comme Identificateur de signaux num riques terrestres le standard DVB C Page 40 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX 5 13 Configuration des Mesures Afin d effectuer les mesures de quelques types de signaux il peut tre n cessaire que Putilisateur introduire quelques param tres relatifs aux caract ristiques particuli res de ces signaux quand la d tection automatique n est pas possible on ces ci diff rent de ce correspondant au standard D Pousser la touche de configuration de mesures E 17 pour acc der au menu de CONFIGURATION et tourner la mollette 1 pour acc der aux param tres relatifs au signal modifiables par Putilisateur 5 13 1 Conf
131. est illumin quand l appareil travaille avec les fr quences et les canaux correspondants la bande satellite T Indicateur qui est illumin quand l appareil travaille avec les fr quences et les canaux correspondants la bande terrestre UE A lt CONFIGURATION DES MESURES ll permet la commutation entre le mode de mesures pour TV Num rique ou TV Analogique D Indicateur qui est illumin quand l appareil travaille avec des signaux num riques A Indicateur qui est illumin quand l appareil travaille avec des signaux analogiques 6 t 1 a mno CONTROLE D IMAGE Activation des menus de contr le de VOLUME de CONTRASTE de LUMINOSIT de SATURATION et de NUANCE uniquement pour le syst me de couleur NTSC Touche num ro 6 pour l entr e de donn es num riques Page 22 11 2013 21 22 MANUEL D UTILISATION PRODIG 5 ZXPROMAX 7 DiSEqC pars DISEQC Seulement dans la bande satellite Il permet d ajuster des param tres de configuration en bande satellite Touche num ro 7 pour l entr e de donn es num riques 8 tuv OUTILS PR F RENCES ll active le menu d Outils pulsation courte Information Appareil Pr sente l information sur l appareil PN num ro de produit Nombre R f rence version du software de contr le configuration fournie etc Test Att nuation Seulement dans la bande terrestre S lectionne la fonction de v rification des r seaux de distribution de sig
132. fabriquant L afficheur TFT peut montrer des pixels non allum s ou allum s en permanence Ceci ne peut pas tre reput d un d faut de fabrication tant que conform ment la norme de qualit du fabricant l existence d un maximum de 9 pixels de ces caract ristiques est admise Ne seront pas jug s d fauts de fabrication non plus ceux qui ne seraient pas d celables plus de 35 cm de distance entre la surface de l cran TFT et l oeuil humain en regard perpendiculaire de l oeuil sur l cran D ailleurs il faut aussi savoir que la vision optimale se produit sous un angle de 15 vers l utilisateur l appareil pos verticalement 7 2 Recommandations de nettoyage PR CAUTION Pour nettoyer la bo te veiller ce que l appareil soit d branch PR CAUTION Pour le nettoyage ne pas utiliser d hydrocarbures aromatiques ou de dissolvants chlor s Ces produits pouvant attaquer les mat riaux utilis s pour la fabrication de la bo te La bo te devra tre nettoy e l aide d une l g re solution de d tergent et d eau appliqu e avec un chiffon doux et humide S cher soigneusement avant d utiliser de nouveau l appareil PR CAUTION N utilisez pas pour le nettoyage du panneau avant et en particulier les viseurs alcool ou ses d riv s ces produits peuvent attaquer les propri t s m caniques des mat riaux et diminuer leur p riode de la vie utile Ver 5 1 4th Edition Page 70 11 2013
133. fter Viterbi Figura 32 Sistema de recepci n digital v a sat lite DVB S QPSK 5 2E 8 Figura 33 Pantalla de medida del VBER de se ales moduladas en QPSK La medida del BER se presenta en valor absoluto en notaci n cient fica 2 0 E 3 significa 2 bits incorrectos de cada 1 000 y mediante una barra anal gica cuanto menor sea su longitud mejor ser la calidad de la se al La representaci n anal gica se presenta sobre una escala logar tmica no lineal Con el fin de tener una referencia sobre la calidad de una imagen se considera que un sistema tiene una calidad aceptable cuando se produce menos de un error no corregible por cada hora de transmisi n A esta frontera se le denomina QEF del ingl s Quasi Error Free y corresponde a una tasa de error aproximada despu s de Viterbi de 4 2 0E 4 BER 2 0x10 es decir 2 bits err neos de cada 10 000 Este valor se ha marcado sobre la barra de la medida del BER despu s de Viterbi y por lo tanto la medida del BER para se ales aceptables debe encontrarse a la izquierda de esta marca A continuaci n se presenta la frecuencia de sinton a y la desviaci n de frecuencia en MHz respecto de la frecuencia de sinton a que optimiza el BER por ejemplo Freq 1777 0 1 2 MHz 11 2013 P gina 57 ZXPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Finalmente se muestra una l nea de estado con informaci n respecto a la se al detectada Los posibles mensajes
134. g that the installation status is the one indicated by the equipment 5 19 SATCR function By means of function SATCR it is possible to control the devices of a TV installation satellite that are compatible with the SatCR technology Satellite Channel Router which allows to concentrate manifold down frequencys slots by an only cable By this way each user using a slot can tune and decode any signal present in the satellite In order to select the SATRC function press the DiSEqC key 21 from frontal panel and using the rotary selector 1 activate the SATRC option In the display are the configuration options that users can modify slot selection number of slots device address Frequency sep pilot signal activation and finally the frequencies corresponding to each slot Ladi sce CATELLITE LE SELECTED SLOT 1 i 20 Bpv dB Figure 41 SatCR command screen 8 SatCR is a trademark of STMicroelectronics 11 2013 Page 65 AXPROMAX USER S MANUAL PRODIG 5 When activating the Enable Pilots options the SatCR device located in the headend emits a pilot signal with constant level for each down frequency slot This function facilitates the verification and identification for different satellite channels that are available in the installation The SatCR technology is being developed and tested in many countries 5 20 Using the alphanumeric keyboard In order to enter numerical data or text the built in a
135. ge ce qui fait que si l on mesure le taux d erreur a la sortie du d modulateur de QPSK apr s Viterbi et a la sortie du d codeur de Reed Solomon l on obtient des taux d erreurs diff rents C est pour cela que le PRODIG 5 EXPLORER proportionne la mesure du BER avant la correction d erreurs apr s Viterbi VBER BER before FEC BER after Viterbi OD VITERBI REED SOLOMON gt Figure 32 Syst me de r ception num rique par satellite DVB S QPSK 5 2E 8 Figure 33 Ecran de mesure du VBER de signaux modul s en QPSK La mesure du BER est pr sent e en valeur absolue en notation scientifique 2 0 E 3 signifie 2 bits incorrects pour chaque 1 000 et l aide d une barre analogique plus sa longueur est petite meilleure sera la qualit du signal La repr sentation analogique est pr sent e sur une chelle logarithmique pas lin aire Afin d avoir une r f rence sur la qualit d une image l on consid re qu un syst me a une qualit acceptable lorsqu il se produit moins d une erreur non corrigible pour chaque heure de transmission L on appelle cette fronti re QEF de l anglais Quasi Error Free et cela correspond a un taux d erreur apr s Viterbi de 2 0E 4 BER 2 0x10 2 bits incorrects pour chaque 10 000 Cette valeur a t marqu e sur la barre de la mesure du BER apr s Viterbi et c est pour cela que la mesure du BER pour des signaux acceptables doit se trouver sur la gauche de ce
136. h band local oscillator 11 2013 Page 43 ZXPROMAX USER S MANUAL PRODIG 5 IMPORTANT REMARK DVB channels tuning may require an adjusting process It is recommended to follow next procedure 4 From the spectrum analyser mode ami 13 tune the channel at its central frequency 3 Switch to Measurements mode cer 12 measurement selection If in the lower line of the screen does not appear MPEG 2 message and consequently BER is unacceptable by turning the rotary selector deviate the tuning frequency until MPEG 2 message appears Finally tune channel again to minimize the frequency deviation which optimizes the BER and therefore minimize the BER If it is not possible to detect any MPEG 2 channel make sure that digital signal parameters are correctly defined 5 14 Selecting the Measurements The types of measurements available depend on the operating band terrestrial or satellite and the type of signals analogue or digital Terrestrial band Analogue channels Level Level measurement of the currently tuned carrier Video Audio Video carrier to audio carrier ratio C N Ratio between the modulated signal power and the equivalent noise power for a same bandwidth Terrestrial band Digital channels DVB C and DVB T Channel power Channel power is measured assuming that power spectral density is uniform throughout channel bandwidth To measure it correctly it is indispensable to define the Channel BW Page
137. hat is to say two incorrect bits of every 1 000 and through an analogue bar as its length is smaller the signal quality will be better The analogue representation is done on a logarithmic scale not linear With the aim to have a reference about the signal quality it is considered that a system has a good quality when it decodes less than one non correctable error for every transmission hour This border is known as QEF Quasi Error Free and it corresponds approximately to a BER after Viterbi of 2 0E 4 BER 2 0x10 This value is marked on the measurement bar of the BER after Viterbi and therefore BER for acceptable signals must be at the left side of this mark Next it is shown the tuning frequency and the frequency deviation in MHz between the tuned frequency and the one which optimizes the BER i e Freq 1777 0 1 2 MHZ Finally it is shown a status line with information about the detected signal The possible messages that can appear and its meaning are shown in the following list The messages are exposed from less to more fulfilment of the MPEG 2 standard No signal received Any signal has been detected Signal received A signal is detected but it can not be decoded Carrier recovered A digital carrier has been detected but it can not be decoded 11 2013 Page 57 AXPROMAX USER S MANUAL PRODIG 5 Viterbi synchronized A digital carrier has been detected and the Viterbi algorithm is synchronized but too many fram
138. ia y el margen de frecuencias a representar span As como el desplazamiento por los diferentes men s y submen s que aparecen en el monitor MONITOR TECLADO PRINCIPAL 12 teclas para selecci n de funciones y entrada de datos alfanum ricos P gina 20 11 2013 10 11 12 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX 48 19 49 9 ida E Mhl ABC g DEF g GHI 0 KE pise amp A m MNO PARS TUV WXYZ 35554 Figura 4 Teclado principal a D b e TECLA TV Permite visualizar la imagen de TV correspondiente a la se al de entrada as como datos relativos a la recepci n de la se al de v deo Tecla n mero 1 para la entrada de datos num ricos yf y AG ie 154 2 asc ALIMENTACI N DE LAS UNIDADES EXTERIORES Permite seleccionar la alimentaci n de las unidades exteriores Los valores de alimentaci n pueden ser Exterior 5 V 13 V 15 V 18 V y 24 V para la banda terrestre y Exterior 5 V 13 V 15 V 18 V 24 V 13 V 22 kHz y 18 V 22 kHz para la banda sat lite Tecla n mero 2 para la entrada de datos num ricos 3 ver MEDIDAS Permite seleccionar el tipo de medida Los tipos de medida seleccionables dependen de la banda del est ndar y del modo de operaci n Tecla n mero 3 para la entrada de datos num ricos 11 2013 P gina 21 13 14 15 16 17 18 19 20 ZXPROMA
139. ica un canal digital una vez finalizada la adquisici n de la tabla de servicios SDT Service Description Table es posible acceder a la lista de servicios contenidos en la tabla Para ello situar el selector de campo mediante los cursores verticales 2 6 sobre el campo del servicio activo p e Veo TV en la siguiente figura y a continuaci n pulsar el selector rotativo 1 Aparecer entonces el men SERVICIOS DIGITALES con los servicios disponibles en el M ltiplex digital Mover los cursores verticales 6 o girar el selector rotativo 1 y pulsarlo para seleccionar el servicio que se desee visualizar en pantalla 11 2013 P gina 63 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 DTV LIBRE PID 1 PID MP ML 120x576i 3 50 Hz mponent MD RED Vistal VIDEO 3 PAYS r eO SZ AUDI O 192 kbit s MPEG 1 L 2 Figura 38 Visualizaci n de un canal digital Servicios Digitales Tambi n es posible cambiar el servicio activo actuando directamente sobre los cursores horizontales 6 una vez se haya seleccionado el campo del servicio en la ventana de informaci n del canal sintonizado 5 17 Funci n Alinear Antenas Permite seleccionar la funci n Alinear Antenas que facilita el apuntamiento de antenas mediante un barrido m s r pido sin presentaci n de medidas num ricas La pantalla aparece dividida en dos partes en la izquierda muestra el espectro de las se ales presentes en la banda y en la derecha dos barras
140. ication de signaux ENTR E RF Impedace Connecteur Signal maximum Tension d entr e maximale DC a 100 Hz 45 MHz 2150 MHz Synth se num rique de fr quence Syntonie continue de 45 a 865 MHz et de 950 a 2150 MHz Canal ou Fr quence FI ou directe en bande satellite Configurable pour chaque session 45 865 MHz 50 kHz 950 2150 MHz lt 200 kHz span FULL 500 200 100 50 32 16 MHz Niveau seuil s lectionnable S lection DVB T ou DVB C Analogiques et num riques Automatique 750 Universel avec adaptateur BNC ou F 130 dBuV 50 Vrms si aliment par l alimentateur AL 103 30 Vrms pas aliment par l alimentateur AL 103 130 dBuV MESURE DE SIGNAUX NUM RIQUES MARGE DE PUISSANCE COFDM QAM QPSK MESURES DVB T COFDM Pr sentation DVB C QAM Pr sentation DVB S QPSK Pr sentation Page 4 45 dBuV 100 dBpV 45 dBuV 110 dBuV 44 dBuV 114 dBuV Puissance CBER VBER MER C N Num rique et barre de niveau Puissance BER MER C N Num rique et barre de niveau Puissance CBER VBER MER C N Num rique et barre de niveau 11 2013 MANUEL D UTILISATION PRODIG 5 PARAMETRES DU SIGNAL COFDM Porteuses Intervalle de garde Code Rate Modulation Inversion spectrale Hi rarchie PARAMETRES DU SIGNAL QAM D modulation Vitesse de symbole Facteur de roll off a du filtre de Nyquist Inversion spectrale PARAMETRES DU SIGNAL QPSK Vitesse de symbole Facteur
141. ication of a channel unknown before going to the next one Only satellite band Selects the C band or Ku band for tuning satellite signals Activates the automatic power off mode Select the power off timeout between 1 and 120 minutes Select the measurements units dBuV dBmV or dBm Select the movement sense CW clockwise or CCW counterclockwise Exit from preferences menu Key number 8 to enter numeric data Page 24 11 2013 9 A 23 wxyz ANTENNA ALIGNMENT Tool for faster sweep antenna alignment at terrestrial and satellite bands Displays the measurements by means of a graph level bar Key number 9 to enter numeric data 0 24 TUNING BY CHANNEL OR FREQUENCY Switches tuning mode between channel and frequency In channel mode the tuning frequency is defined by the active channels table CCIR Key number 0 to enter numeric data 25 AUTO ID EXPLORER Activates the automatic identification function short pulsation The instrument will try to identify the signal under test First it recognises whether the signal is an analogue channel or a digital one If the channel is analogue it determines the television standard of the signal detected When the signal is digital it analyses the modulation type QAM QPSK COFDM and all the associated parameters such as the carriers 2k 8k the symbol rate the code rate etc and it tries to lock to the signal In the spectrum analyser mode it
142. idth to be selected between 8 MHz 7 MHz and 6 MHz The selection of this parameter is essential for the correct operation of the tuner as it affects the frequency separation of the carriers 4 Spectral Inv spectral inversion This option enables spectral inversion to be applied to the input signal though in the majority of cases it should be in the OFF position not inversion This configuration menu shows besides the user definable COFDM signal parameters the value of the rest of signal parameters detected automatically Code Rate Also known as Viterbi ratio defines the ratio between the data bits number and the total number of bits transmitted the difference corresponds to the number of control bits for the error detection and recovery Modulations Carriers modulation It also defines the system noise immunity QPSK 16 QAM and 64 QAM Hierarchy The DVB T norm contemplates the possibility to make a TDT transmission with hierarchical levels it is to say a simultaneous transmission of the same program with different image qualities and noise protection levels in order the receiver can exchange to a signal of smaller quality when the reception conditions are not optimal 11 2013 Page 41 ZXPROMAX USER S MANUAL PRODIG 5 al NUD_T COCDM Pi SIGNAL a 0 Figure 19 Screen of mesurement configuration COFDM signals 5 13 3 DVB S QPSK Digital Channel Configuration D Press the Measurements Configura
143. ieur au seuil pr alablement d fini au moyen de l option Seuil Niveau Ter pour canaux analogiques Seuil Puissance Ter et Seuil Puissance Sat pour canaux num riques du menu de PR F RENCES 5 6 S lection de la Configuration de Mesure Analogique Num rique La r alisation de la mesure des caract ristiques d un canal particulier d pend en premier lieu du type de modulation analogique ou num rique D l aide de la touche 20 il est possible de passer des canaux analogiques D aux canaux num riques et vice versa Pousser la touche 20 pour qu apparaisse le menu de CONFIGURATION de la mesure et ensuite choisir l option Signal en tournant et en poussant la mollette 1 L option Signal permet d tablir le type de signal qu on souhaite mesurer En passant d un type de modulation a un autre le PRODIG 5 EXPLORER active la derni re configuration de mesure utilis e pour ce type de modulation 5 7 Alimentation des Unit s Externes Gr ce au PRODIG 5 EXPLORER il est possible de fournir la tension n cessaire pour l alimentation des unit s externes amplificateurs pr alables d antenne dans le cas de t l vision terrestre ou LNB dans le cas de t l vision par satellite ou simulateurs de F I AN Niveaux maximum d entr e DC a 100 Hz 50 V rms si aliment par l alimentateur AL 103 30 V rms pas aliment par l alimentateur AL 103 45 MHz 2150 MHz 130 dBuV Page 30 11 2013 MANUEL D UTILI
144. igera soluci n de detergente con agua y aplicada mediante un pa o suave humedecido Secar completamente antes de volver a usar el equipo PRECAUCI N No se use para la limpieza del panel frontal y en particular de los visores alcohol o sus derivados estos productos pueden atacar las propiedades mec nicas de los materiales y disminuir su tiempo de vida til 11 2013 P gina 71 TABLE OF CONTENTS 1 GENERAL ciclista 1 1 1 Description 1 2 Specifications si 4 2 SAFETY RULES vada E r ENEA ES E ENSANSE 9 2 1 General safety rules ss 9 2 2 Descriptive Examples of Over Voltage Categories ccc eee eee 11 3 INSTALLATION corriendo rio 13 3 1 Power Supply sisc iesssccnicaieiecnasin re retenir ns ni eme A ETATE L ari Ei 13 3 1 1 Operation using the External DC Charger 2 13 3 1 2 Operation using the Battery 13 3 1 2 1 Battery Charging we l4 3 2 Installation and Start up evsevcccccsiscccssscccesactsscecaesieesaasueinesicueuseusebeanesisacacedeensaicaes 14 4 QUICK USER GUIDE vtr ial ein aes 5 OPERATING INSTRUCTIONS nr 5 1 Description of the Controls and Elements 5 2 Adjustment of Volume and Monitor Parameters 5 3 Selecting the Operation Mode TV Spectrum Analyser Measurements 5 4 Channel Tuning Frequency Tuning eee eee seen nan rn ana nanar cara 5 5 Automatic Transmission Search 5 6 Selecting the measure
145. ignal d entr e d passe 130 dB V 1 V ou soup onnez de probl mes d intermodulation Cet accessoire permet le pas des tensions CC que sont utilis s pour alimenter les unit s ext rieures LNB et amplificateurs Figure 6 Connexion de l att nuateur externe l entr e RF 30 Page 26 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX ATTENTION A Il faut remarquer le besoin de prot ger l entr e 30 avec un accessoire lequel limine les tensions CA que sont utilis s aux c bles de CATV n cessaires pour alimenter les amplificateurs et au contr le distance 4 6 amp 6 62 63 Figure 7 El ments du panneau lat ral 31 Bouton de RESET Il permet de r initialiser l appareil en cas d anomalie dans son fonctionnement 32 Entr e d alimentation externe de 12 V 83 Haut parleur 34 Ventilateur 35 Prise P ritel 36 Crochet ruban de transport 11 2013 Page 27 AxPROMAX MANUEL D UTILISATION PRODIG 5 Figure 8 Panneau post rieur 37 Connecteur RS 232C Pour des op rations d entretien et calibrage 5 2 R glage des Param tres du Moniteur et du Volume 6 En appuyant plusieurs fois sur la touche 3 on active s quentiellement les menus de contr le de VOLUME de CONTRASTE de LUMINOSIT de SATURATION et aussi de NUANCE celui ci dernier uniquement sur le syst me de couleur NTSC En activant le menu correspo
146. iguration d un Canal Num rique DVB C QAM Co Pousser la touche de configuration de mesures 17 pour acc der au menu de CONFIGURATION et tourner la mollette 1 pour acc der aux param tres relatifs au signal QAM que peut tablir l utilisateur et qui sont d crits ci dessous 1 Modulations Il d fine le type de modulation En s lectionnant cette fonction et en poussant la mollette 1 il appara tra un menu au moyen duquel il est possible de s lectionner une des modulations suivantes 16 32 64 128 et 256 2 Symbol Rate Vitesse de Symboles En s lectionnant cette fonction et en poussant la mollette 1 il appara tra un menu au moyen duquel il est possible de s lectionner une des valeurs de vitesse de symboles 3 Inv Spectrale Inversion de spectre En cas de besoin activer l inversion de spectre Oui Si l inversion spectrale est s lectionn e de fa on incorrecte la r ception ne sera pas correcte Call nUD CAAM Pl A SIGNAL 0 FRE CAN Figure 18 cran de configuration des mesures de signaux modul s en QAM 11 2013 Page 41 AxPROMAX MANUEL D UTILISATION PRODIG 5 5 13 2 Configuration d un Canal Num rique DVB T COFDM D x A r Pousser la touche de configuration de mesures 17 pour acc der au menu de CONFIGURATION et tourner la mollette 1 pour acc der aux param tres relatifs au signal COFDM que peut tablir l utilisateur et qui sont d crits ci dessous 1 2
147. information en rapport avec le signal d tect Les possibles messages qui peuvent apparaitre et leur signification se montrent dans la liste suivante dans laquelle on pr sente les diff rent messages par ordre du plus petit au plus grand accomplissement des param tres du standard MPEG 2 Aucun signal On n a d tect aucun signal Signal d tect On a d tect un signal mais il n est pas d codificable Porteuse d tect On a d tect une porteuse num rique mais elle n est pas d codificable MPEG 2 D tection correcte d un signal MPEG 2 11 2013 Page 59 AxPROMAX MANUEL D UTILISATION PRODIG 5 5 15 Analyseur de Spectre Le mode Analyseur de Spectre permet de mani re facile et rapide de voir sur le moniteur tous les signaux pr sents dans la bande ainsi que d effectuer en m me temps 4 Da les mesures Pour lui s lectionner il suffit d enfoncer la touche ex 13 Le moniteur pr sentera l cran du mode spectre tel qu il est pr sent dans la figure suivante Figure 35 Mode Analyseur de Spectre Les lignes horizontales font r f rence au niveau de signal tant les lignes discontinues s par es 10 dB Le niveau de la ligne sup rieure 70 dBuV sur la figure pr c dente appel Niveau de R f rence peut tre modifi l aide des touches de A curseur verticales Pra entre 60 dBuV et 130 dBuV dans pas de 10 dB de 70 dBuV 130 dBuV en bande satellite Dans le sens vertical est
148. ing B 6 Left channel audio input 7 Blue output B 8 Switching voltage 9 Green grounding G 10 Digital bus interface not connected 11 Green output G 12 Digital bus interface not connected 13 Red grounding R 14 Digital bus reserved not connected 15 Red output R 16 Blanked signal not connected 17 Composite video grounding 18 Blanked return not connected 19 Composite video output 20 Video input 21 Connector shield grounding Table 5 Description of the Scart In order to select the SCART connector operation mode between video Input video Output or Automatic from the TV visualisation mode 10 follow the following steps al D 1 Select the Measurement Configuration menu by pressing the 17 key and verify that the type of signal selected is ANALOGUE 2 Select the suitable operation mode tor the SCART by means of the Video Aud Ext option in this menu Page 68 11 2013 7 MAINTENANCE A 7 1 Considerations about the Screen This paragraph offers key considerations regarding the use of the colour screen taken from the specifications of the manufacturer In the TFT display the user may find pixels that do not light up or pixels that are permanently lit This should not be regarded as a defect in the TFT In accordance with the manufacturer quality standard 9 pixels with these characteristics are considered admissible Pixels which are not detected when the distance from the surface of the TFT
149. ing figure Wait for some seconds until the calibration process of three pilots is completed 11 2013 Page 37 ZRPROMAX USER S MANUAL PRODIG 5 Figure 15 SAT IF Test Satellite band 2 MEASUREMENT OF THREE PILOTS THROUGHOUT THE NETWORK Once PRODIG 5 EXPLORER has been calibrated start to make level measurements in the different distribution outlets using the EXPLORER On the screen will appear the attenuation values for the three pilot frequencies measured in the outlet plate see the following figure CALIBRATE E Figure 16 Attenuation measurements in an outlet plate In order to finish measuring press the rotary selector 1 and select the EXIT option Page 38 11 2013 5 12 Spectrum exploration function EXPLORER The Exploration function allows exploring the full frequency band in order to identify the analogue channels and digital presents in agreement with the configuration set in the tuning band In order to activate the function hold pressed the 25 key until the EXPLORER screen appears TESTING CHANNEL SET PROMAX 0 25 50 100 DVB T OK UNI DENTI FI ED ANALOG PAL BG NO SI GNAL FOUND 12 101 PROCESS SUCCESSFUL SAVE AS PROMAX_01 Figure 17 Spectrum exploration screen EXPLORER Whenever the process detects new parameters for some channel it will create a new channel plan containing the detected information NOTE In the case that is desir
150. l El nivel de ruido se mide en 7 r VYo j fruido fsintonia Y Ancho Banda Canal Para medirla correctamente se debe sintonizar el canal en su frecuencia central Relaci n de error de la modulaci n Medida del BER tasa de error para la se al digital antes de la correcci n de errores BER antes del FEC Medida del BER tasa de error para la se al digital despu s de la correcci n de errores BER despu s de Viterbi Banda sat lite Canales anal gicos Nivel C N 11 2013 Medida de nivel de la portadora sintonizada Relaci n entre la potencia de la se al modulada y la potencia de ruido equivalente para el mismo ancho de banda P gina 45 LR PROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Banda sat lite Canales digitales DVB S Potencia del Canal M todo autom tico C N Relaci n entre la potencia de la se al modulada y la potencia de ruido equivalente para el mismo ancho de ancho de banda MER Relaci n de error de la modulaci n CBER Medida del BER tasa de error para la se al digital antes de la correcci n de errores BER antes del FEC VBER Medida del BER tasa de error para la se al digital despu s de la correcci n de errores BER despu s de Viterbi 3 em Para cambiar el tipo de medida pulse la tecla 5 12 En el monitor aparecer n sucesivamente de forma c clica todas las medidas disponibles para la se al sintonizada 5 14 1 TV anal gica Medida del NIVEL de la porta
151. le nombre de canaux le type de signaux transmis ou les caract ristiques de ces derni res Avec les donn es acquises a partir de chaque exploration il cr e un registre qui contient les plans de canaux ind pendants pour chaque syst me ou installation On peut r p ter les sessions de mesure a tout moment en utilisant seulement ces canaux pr syntonis s En permettant alors d acc l rer le processus Dans le panneau frontal est indiqu le type de mesure qu on effectue Terrestre Satellite Analogique Num rique et les donn es sont visualis es au moyen d un cran graphique TFT de 5 de haute r solution L quipement incorpore un capteur pour l ajustement automatique du contraste et la luminosit de l cran en accord avec les conditions environnementales pr sentes chaque moment La taille compacte et le poids l ger de PEXPLORER permettent qu il soit utilis avec une seule main Avec la couverture ou le ruban de transport fourni l appareil peut tre tenu au corps en m me temps qu il se prot ge des incl mences environnementales Le protecteur anti choc fournit une robustesse additionnelle pour les travaux de champ en outre dispose d une valise rigide de transport optionale L appareil a t con u pour viter l entr e accidentelle de liquides dans l int rieur Le PRODIG 5 est con u pour int grer mesures qui requi rent des configurations d op ration tr s diff rentes Par exemple incorpore une fonction sp cifi
152. les transmitidos la diferencia corresponde al n mero de bits de control para la detecci n y recuperaci n de errores Modulaci n Modulaci n empleada por las portadoras Define tambi n la inmunidad al ruido del sistema APSK 16 QAM y 64 QAM Jerarqu a La norma DVB T contempla la posibilidad de realizar una transmisi n de TDT con niveles jer rquicos es decir la transmisi n simult nea del mismo programa con calidades de imagen y niveles de protecci n ante ruido diferentes de forma que el receptor pueda conmutar a una se al de menor calidad cuando las condiciones de recepci n no son ptimas NvD_ T ACcCDM CANALIZACION CCIR Figura 19 Pantalla de configuraci n de medida de se ales moduladas en COFDM P gina 42 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 ZXPROMAX 5 13 3 Configuraci n de un Canal Digital DVB S QPSK D Pulsar la tecla de configuraci n de medidas 17 para acceder al menu de CONFIGURACION y girar el selector rotativo 1 para acceder a los parametros relativos a la se al QPSK que puede establecer el usuario y que se describen a continuaci n 1 Inv Espectral Inversi n Espectral Si es necesario activar la inversi n de espectro Si se selecciona incorrectamente la inversi n de espectro la recepci n no ser correcta 2 Tasa de C digo Velocidad de c digo Tambi n conocido como relaci n de Viterbi Define la relaci n entre el n mero de bits de datos y los bits real
153. lites and cable systems Allowing measurements of analogue signals as well as digital ones When pressing the auto identification key it searches and identifies the signal under test First it recognises whether the signal is an analogue channel or a digital one If the channel is analogue it determines the television standard of the signal When the signal is digital DVB it analyses for each modulation type QAM QPSK COFDM all the associated parameters such as the modulation system carriers 2k 8k symbol rate code rate etc and determines the value of the signals under test The PRODIG 5 includes the main TV standards M N B G I D K and L adopting apart from the characteristic parameters of the standard the correcting automatic system to obtain in all the cases an accurate measuring of the input signal level It accepts any TV system PAL SECAM and NTSC and allows the user to work directly with digital TV signals decoding them so that the television image may be viewed and directly measuring the power carrier noise ratio C N the bit error rate BER and the modulation error ratio MER as well for DVB T COFDM as DVB S QPSK and DVB C QAM signals Being a multistandard instrument it can be efficiently used in any country of the world DS 1BSIMES Trade Mark of the DVB Digital Video Broadcasting Project 4026 11 2013 Page 1 AXPROMAX USER S MANUAL PRODIG 5 Includes a symbol based keyboard that allows the
154. lour amplifier must function at maximum gain which could result in noise appearing all over the television screen with points of colour that disappear when the saturation control is reduced in an extreme case loss of colour may occur 5 15 1 Markers Only in Spectrum Analyser mode The marker in red colour indicates the central frequency or tuning frequency which can be moved by means of turning the rotary Am selector 1 as well in channel as in frequency tuning mode 24 When monitoring a digital signal spectrum also appears two additional markers in white colour which indicate the bandwidth of the digital channel See previous Figure 5 16 TV Operating Mode 1 O When pressing the 2 key from any mode of operation the PRODIG 5 EXPLORER accedes to the TV mode and tries to demodules on the monitor the currently tuned video signal In the monitor will appear the TV picture with a window on the lower part to show for five seconds in the case that the signal is analogue the channel number the frequency the active canalization the colour system and the TV standard DTV FREE VPID APID 1 MP ML 720x576i 4 3 50Hz Component Figure 36 Digital channel monitoring 11 2013 Page 61 ZRPROMAX USER S MANUAL PRODIG 5 If the signal is digital it shows for about five seconds the following parameters channel number frequency active channel plan type of DVB signal service name
155. lphanumeric keyboard must be used Many keys incorporate a number and several letters like the telephone keypad 1 Entering numerical data e g a channel frequency Press the key corresponding to the digit that you wish to enter from the 0 to D the 9 When pressing the decimal point key 17 it enters the character point and later the equipment allows entering two more digits In order to introduce a negative number first press the key 24 until the sign appears lt gt In order to erase a digit move with the cursor horizontal arrow keys 6 placing the cursor behind the digit that is desired to erase and next keep D key 17 pressed until the digit disappears Repeat the operation by each additional digit you wish to eliminate 2 Entering alphanumeric data e g a channel plan name Press the corresponding key of the keyboard 8 letter or digit to be entered The word to be entered can be written by pressing each key The keys must be pressed two seconds before and for a suitable number of times until it appears the expected letter or digit on screen In order to switch between small letters to capital letters and vice versa first press the key 25 AL Note Press the upper arrow cursor key P to cancel any data entry through the keyboard When maintaining pressed a numerical key in text mode the corresponding number is directly entered Page 66 11 2013 6 DESCRIPTION OF THE INPUTS AND OUTPUTS
156. lt gt 3 Pulsar _ 10 para visualizar los canales detectados y W 6 para cambiar de canal en la lista de canales detectados PASO 4 Para hacer una identificaci n del canal sintonizado 5 Ss A 1 Seleccionar la banda de frecuencias de exploraci n i 14 terrestre o sat lite 2 Activar el proceso de identificaci n pulsando una vez sobre la tecla 25 1 3 Pulsar _e 10 para visualizar la se al detectada del canal o frecuencia 4 identificada o ou 13 para monitorizar el espectro que le corresponde NOTA En el caso que se desee explorar o identificar se ales DVB C es necesario 8 acceder previamente al men de PREFERENCIAS ruv 22 y seleccionar como Identificador de se ales digitales terrestres el est ndar DVB C PASO 5 Para hacer medidas 1 Seleccionar el canal o frecuencia 24 a medir mediante el selector rotativo 1 3 2 Pulsar la tecla de selecci n del tipo de medida ver 12 hasta que aparezca la pantalla correspondiente a la medida que se desea obtener P gina 16 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXPROMAX PASO 6 Para monitorizar el espectro de frecuencias 5 es 1 Seleccionar la banda de frecuencias a representar sx 14 terrestre o sat lite 4 2 Activar el barrido pulsando la tecla sw 13 A 3 Pulsar Pa para modificar el nivel de referencia en el eje vertical A aP 4 Pulsar 6 para modificar el span en el eje horizontal PASO 7
157. ment configuration Analogue Digital signal 5 7 External Units Power Supply 5 8 Automatic signal identification function AUTO ID 5 9 Channel plans iio iaa 5 10 Acquisition function DATALOGGER cccccccnccncn 5 10 1 Datalogger for Attenuation and IF SAT test 5 11 Verification of distribution networks 5 12 Spectrum exploration function EXPLORER PR 5 13 Measurements configuration 5 13 1 DVB C QAM Digital Channel Configuration oononnnnninninnrnninninacaraninas 5 13 2 DVB T COFDM Digital Channel Configuration Ke 5 13 3 DVB S QPSK Digital Channel Configuration 5 14 Selecting the Measurements sisi 5 14 1 Analogue TV Measuring the Video Carrier Level sis 5 14 2 Analogue TV Measuring the Video Audio ratio V A 47 5 14 3 Analogue Digital TV Measuring the Carrier Noise ratio C N 48 5 14 4 Digital TV Measuring the Power of Digital Channels ooococcnnnncinninmomm 50 ZXPROMAX USER S MANUAL PRODIG 5 5 14 5 Digital TV Measuring BER sis 51 5 14 5 1 DVB CSIQMalS csc cs cccecversetiessciateecesctascenieg sei spnancecicaaspdeastacescaneevaesengzcas 52 5 14 5 2 DVB T signals 5 14 5 3 DVB S signals non 5 14 6 Digital TV Measuring MER iii 58 5 15 SPOCtruM ANALYSE uicorciancionics moirncininaced cian edd aprendo icon ie depa abad 59 5 15 1 Markers 5 16 TV Operating Mode 5 17 Antenna Alignment Func
158. n Datos La funci n de Adquisici n permite realizar y almacenar medidas de forma totalmente autom tica Puede almacenar para cada adquisici n medidas realizadas en diferentes puntos de la instalaci n Las medidas se realizan sobre los par metros registrados para todos los canales presentes en la tabla de canales activa tanto anal gicos como digitales 8 Para seleccionar la funci n Adquisici n activar el men de UTILIDADES w 22 y seleccionar la opci n HACER ADQUISICIONES Seguidamente girando el selector rotativo 1 seleccionar una adquisici n previamente almacenada o bien una NUEVA ADQUISICI N P gina 34 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX PUNTO DE MEDIDA CANALI ZACI ON FREC Figura 11 Pantalla de adquisici n de medidas En el caso de canales digitales y dado que stos implican un mayor proceso de c lculo en la parte inferior de la pantalla aparece un contador del tiempo que resta para finalizar las medidas del canal En la esquina superior indica el canal que est midiendo del total de la canalizaci n Para acceder a los diferentes campos de la pantalla se deben pulsar las teclas A lt gt de cursor y 6 y a continuaci n si desea editarlos pulse el selector rotativo 1 Tras seleccionar el campo INICIAR el equipo proceder de forma autom tica a la realizaci n de las medidas Cuando finalice el proceso ofrecer la opci n de repetirlas por ejemplo para otro
159. nal source in the input connector 30 RF SOURCE YO 3 L RF IN Figure 2 Power on and signal connection 11 2013 Page 15 ZXPROMAX USER S MANUAL PRODIG 5 STEP 3 To carry out a complete channel band exploration 5 ws 1 Select the frequency band to explore E 14 terrestrial or satellite 2 Activate the exploration process by holding 25 key pressed 1 ap 3 Press 10 key to visualise the channels detected and 6 to change between channels from detected channels list STEP 4 To carry out the tuned channel identification 5 x 1 Select the frequency band to explore E 14 terrestrial or satellite 2 Activate the identification process pressing once on 25 key 1 O 3 Press lt e 10 key to visualise the signal detected from channel or frequency 4 ry Ida identified or cx 13 to monitor the corresponding spectrum NOTE Inthe case that is desired to explore or identify DVB C signals it is necessary to select previously DVB C standard as digital signal identifier through 22 PREFERENCES menu STEP 5 Making measurements 0 ULL 1 Select the channel or frequency 24 to measure by means of the rotary selector 1 EZ 2 Press sr 12 key to select the type of measurement until on screen appears the corresponding measurement Page 16 11 2013 STEP 6 Frequency spectrum monitoring 5 us 1 Select the frequency band a to graph 14 terrestri
160. naux dans la bande terrestre Essai F I Sat Seulement dans la bande satellite S lectionne la fonction de v rification des reseaux de distribution de signaux dans la bande satellite Faire Saisies Fonction pour r aliser des acquisitions de mesure de mani re totalement automatique Voir Saisies Visualise la liste d acquisitions r alis es Effacer Saisies limine une acquisition effectu e pr alablement Effacer le Plan Efface le plan de canaux choisi Effacer Canaux Efface un canal du plan actif Ins rer Canaux Ins re un canal dans le plan de canaux actif depuis un autre plan standard Sortir Sortie du menu d Outils Il active le menu de Pr f rences pulsation longue Langue Choisit la langue entre DEUTSCH ENGLISH ESPANOL FRAN AIS ITALIANO et PYCCKMH Bip Touches Active ON ou d sactive OFF la sonnerie 11 2013 Page 23 AxPROMAX Affichage Senseur Lumiere Identif Ter Seuil Puissance Ter Seuil Niveau Ter Seuil Puissance Sat C N Temps Max Identifier Bande Sat Arr t Automatique Temps pour Arr t Unit s Mollette Sortir MANUEL D UTILISATION PRODIG 5 S lection de la couleur de fond de l cran Active le capteur de luminosit environnementale 5 pour le calibrage automatique du contraste et la luminosit de l cran Options disponibles Contraste Haut dans conditions de basse luminosit Contraste Bas dans conditions de haute luminosit et AU
161. ndant a chaque param tre appara t a l cran une barre horizontale dont la longueur est proportionnelle au niveau du param tre Pour modifier la valeur de ce param tre il suffit de tourner la mollette 1 Pour sortir de ces menus et valider les nouvelles valeurs pousser la mollette 1 Page 28 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX 5 3 S lection du Mode d Op ration TV Analyseur de Spectre Mesures Le PRODIG 5 EXPLORER dispose de trois modes d op ration de base mode d op ration TV mode d op ration Analyseur de Spectre et mode de Mesures Pour 4 Nu passer du mode TV au mode Analyseur de Spectre on doit pousser la touche eu 3 Aus 13 Pour passer au mode Mesures il suffit de pousser la touche 12 Dans le mode d op ration TV l cran appara t le signal de t l vision d module Ce c est le mode d op ration par d faut et sur lu peuvent tre choisies de multiples fonctions comme on montre dans les prochains paragraphes Dans le mode Analyseur de Spectre c est une repr sentation du spectre de puissance de la bande active terrestre ou satellite qui appara t l cran l expansion et le niveau de r f rence sont variables Dans le mode de Mesures a l cran apparaissent les mesures disponibles en fonction du type de signal choisi 5 4 Syntonie par Canal Syntonie par Fr quence 0 AU En poussant la touche 24 on passe de syntonie par fr quence
162. nne chaque 10000000 et l aide d une barre analogique plus sa longueur est petite meilleure sera la qualit du signal La repr sentation analogique est pr sent e sur une chelle logarithmique pas lin aire c est dire que les marques de la barre correspondent Pexposant de la mesure Afin d avoir une r f rence sur la qualit d une image l on consid re qu un syst me a une qualit acceptable lorsqu il se produit moins d une erreur non corrigible pour chaque heure de transmission L on appelle cette fronti re QEF de l anglais Quasi Error Free et cela correspond a un taux d erreur apr s Viterbi de 2 0E 4 BER 4 2 0x10 c est a dire 2 bits erron s pour chaque 10000 Cette valeur a t marqu e sur la barre de la mesure du BER apr s Viterbi et c est pour cela que la mesure du BER pour des signaux acceptables doit se trouver sur la gauche de cette marque Derni rement il appara t une ligne d tat que pr sente d information en rapport avec le signal d tect Les possibles messages qui peuvent apparaitre et leur signification se montrent dans la liste suivante dans laquelle on pr sente les diff rent messages par ordre du plus petit au plus grand accomplissement des param tres du standard MPEG 2 11 2013 Page 55 AxPROMAX MANUEL D UTILISATION PRODIG 5 Aucun signal On n a d tect aucun signal Timing recovered Seulement il est possible de r cup rer le temps de symbole AFC in lock Le
163. o 1 seleccionar una tensi n de 13 V Finalmente seleccionar la aplicaci n PRUEBA FI SAT ICT del men de 8 UTILIDADES 3 22 para banda Sat lite o bien la aplicaci n TEST ATENUACI N para banda terrestre conectar el generador en el punto donde ir conectada la antena origen de la se al y mediante los cursores horizontales 6 acceder a la funci n Calibrar ver siguiente figura Esperar unos segundos hasta que acabe el proceso de calibraci n de las tres frecuencias piloto Figura 15 Prueba FI SAT ICT Banda Sat lite 2 MEDIDA DE LOS TRES PILOTOS A LO LARGO DE LA RED Una vez calibrado el PRODIG 5 EXPLORER proceder a tomar las lecturas de los niveles en las diferentes tomas de distribuci n mediante el EXPLORER En la pantalla aparecer n los valores de las atenuaciones medidas para las tres frecuencias piloto en una determinada toma v ase figura siguiente P gina 38 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 LR PROMAX CNE M SALIR Figura 16 Medidas de atenuaci n para una toma Para finalizar las medidas pulsar el selector rotativo 1 y seleccionar la opci n SALIR 5 12 Funci n de Exploraci n del espectro EXPLORER La funci n de Exploraci n permite explorar la banda de frecuencias completa para identificar los canales anal gicos y digitales presentes de acuerdo con la configuraci n establecida en la banda de sinton a Para activar la funci n mantener presionada la tecla
164. o Analizador de Espectros permite comprobar r pidamente las se ales presentes en la banda de frecuencias y realizar medidas al mismo tiempo Para 4 seleccionarlo basta pulsar la tecla sw 13 En el monitor aparecer una pantalla tal como se describe en la figura siguiente 11 2013 P gina 59 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Figura 35 Modo Analizador de Espectros Las l neas horizontales referencian el nivel de se al estando las l neas discontinuas separadas 10 dB El nivel de la l nea superior 70 en la figura anterior se denomina Nivel de Referencia y se puede modificar mediante las teclas de cursor verticales 6 entre 60 dBuV y 130 dBuV en saltos de 10 dB de 70 dBuV a 130 dBuV en banda sat lite En sentido vertical se representa el nivel de se al para cada frecuencia estando las frecuencias m s bajas en la parte izquierda de la pantalla y las m s altas en la derecha La amplitud de los l bulos est calibrada En el ejemplo de la figura anterior el nivel de ruido est en torno a los 25 dBuV y el l bulo con mayor nivel de se al el tercero por la derecha posee unos 70 dBuV El margen de frecuencias representado llamado span de aqu en adelante tambi n puede modificarse mediante las teclas de cursor horizontales 6 De esta forma es posible seleccionar el margen de frecuencias presentado en pantalla en el modo Analizador de Espectros entre Completo toda la banda 500 MHz 200 MHz 100 M
165. on ESSAI F I SAT Fonction TEST ATTENUATION MANUEL D UTILISATION PRODIG 5 1 5 dB 30 120 dBuV 45 865 MHz 22 C 5 C 2 5 dB 40 100 dByV 950 2050 MHz 22 C 5 C ty Niveau Rapport Vid o Audio et Rapport Porteuse Bruit Puissance du Canal Rapport Porteuse Bruit et Identification du canal Niveau et Rapport Porteuse Bruit Puissance du Canal et Rapport Porteuse Bruit Acquisition et registre automatique de mesures Niveau C N et V A Offset fr quence d tection MPEG 2 puissance rapport C N MER CBER VBER et marge de bruit R ponse pour r seaux de distribution Fl en bande satellite R ponse pour r seaux de distribution de signaux en bande terrestre MODE ANALYSEUR DE SPECTRE Bande satellite Bandes terrestres Largeur de bande de mesure Terrestre Satellite Expansion Terrestre Satellite Marqueurs Mesures Bandes terrestres Canaux analogiques Canaux num riques Bande satellite Canaux analogiques Canaux num riques 30 dBuV 120 dBuV 31 6 uV 1 V 10 dBuV 120 dBuV 3 16 pV 1 V 230 kHz 4 MHz Full span bande compl te 500 200 100 50 32 16 8 MHz s lectionnable Full span bande compl te 500 200 100 50 32 16 MHz s lectionnable 1 avec indication de fr quence et niveau Niveau Puissance du canal Niveau Puissance du canal 3 Au moyen du logiciel PkTools pour PC Fonction pour utiliser avec le simulateur de F I RP 0
166. on cnn ncnn cnn nc rncnnnn 30 5 6 Selecci n de la configuraci n de medida se al Anal gica Digital 30 5 7 Alimentaci n de las Unidades Exteriores 30 5 8 Funci n de Identificaci n Autom tica de se ales AUTO ID 32 5 9 Listas de Canales iconos lr 252399 5 10 Funci n Adquisici n Adquisici n Datos 2 34 5 10 1 Adquisiciones para Test de Atenuaci n y prueba Fl SAT ICT 35 5 11 Comprobaci n de redes de distribuci n ene 5 12 Funci n de Exploraci n del espectro EXPLORER ss 5 13 Configuraci n de las Medidas anna nr cnn nac nica ranranc 5 13 1 Configuraci n de un Canal Digital DVB C QAM 5 13 2 Configuraci n de un Canal Digital DVB T COFDM E 5 13 3 Configuraci n de un Canal Digital DVB S QPSK 5 14 Selecci n de las Medidas 5 14 1 TV anal gica Medida del NIVEL de la portadora de v deo 46 5 14 2 TV anal gica Medida de la Relaci n V deo Audio V A 48 5 143 TV anal gica digital Medida de la Relaci n Portadora Ruido C N 48 5 14 4 TV digital Medida de Potencia de un Canal Potencia 51 5 14 5 TV digital Medida del BER n se bl 5 14 5 1 Se ales DVB C 5 D2 5 14 5 2 Se ales DVB T cocinas nel 54 ZXPROMAX MANUAL DE INSTRUCCIONES PRODIG 5
167. ories to store automatically the different data acquisitions i e acquisition name test points frequency channel plan etc Moreover the DATALOGGER function makes it much easier to test systems in which a large number of measurements have to be made and enables further processing of all the information acquired using a computer system Also this meter incorporates a DiSEqC command generator and permits to supply different voltages to the external unit 5 V 13 V 15 V 18 V 24 V and includes an EUROCONNECTOR or Scart connector for audio video input output The PRODIG 5 is powered by rechargeable battery or connected to the mains through the supplied external DC power charger It incorporates a RS 232C interface which enables service to be carried out and the checking setup and calibration processes This instrument due to its extreme compact design technical specifications and low cost becomes the industry standard for the installer 2 DiSEqCTM is a trademark of EUTELSAT 11 2013 Page 3 AxPROMAX 1 2 Specifications A USER S MANUAL PRODIG 5 CONFIGURATION FOR MEASURING LEVEL AND POWER TUNING Tuning modes Resolution Automatic search Explorer Signal identification RF INPUT Impedance Connector Maximum signal Maximum input voltage DC to 100 Hz 45 MHz to 2150 MHz Digital frequency synthesis Continuous tuning from 45 to 865 MHz and from 950 to 2150 MHz Chanel or frequency IF o
168. ou a d autres biens SUMARIO CONTENTS SOMMAIRE Manual espa ol English Mandat nn e Mantel acaso MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX INDICE 1 GENERALIDADES 2122 ais ize scctersecsctssasidcxsaiccsdessecevacausdveinesisacaceeesbivsepscessacbitasinaziess 1 1 1 Descripci n ss 1 2 Especificaciones 4 2 PRESCRIPCIONES DE SEGURIDAD sise 9 2 1 GMCS miii ii aia 9 2 2 Ejemplos Descriptivos de las Categor as de SobretensiOn ooococonciocinimmm 11 3 INSTALACI N conca 13 3 1 Alimentaci n lt cooisoiscaitccs sitiar retenes ald 3 1 1 Funcionamiento mediante alimentador DC Externo wild 3 1 2 Funcionamiento mediante Bater a eee s 13 3 1 2 1 Carga de la Bater a 14 3 2 Instalaci n y Puesta en Marcha ss 14 4 GUIA R PIDA DE UTILIZACI N een 15 5 INSTRUCCIONES DE UTILIZACION c scsscsscssesssseesessecsessesteseeseesssteseesecseesesseseenes 19 5 1 Descripci n de los Mandos y Elementos ooocicnniccnnncnnonanannconnnnann nano nanonancnnn nos 19 5 2 Ajuste de los Par metros del Monitor y del Volumen 28 5 3 Selecci n del Modo de Operaci n TV Analizador de Espectros Medidas 29 5 4 Sinton a por Canal Sinton a por Frecuencia 29 5 5 B squeda Autom tica de Emisoras onocconcccnocinccconccononnnccconocon
169. pends in the first place on the type of modulation analogue or digital o Use key 20 to switch between analogue and digital channels Press the D 20 key to show the measurements CONFIGURATION menu and select the Signal option by turning and pressing the rotary selector 1 The Signal option allows setting the type of signal to measure When switching to a new type the PRODIG 5 EXPLORER activates the last measurement configuration used for that type of signal 5 7 External Units Power Supply The PRODIG 5 EXPLORER can supply the voltage needed to power the external units antenna preamplifiers in the case of terrestrial TV LNB in the case of satellite TV or IF simulators A Maximum input levels DC to 100 Hz 50 Vrms powered by the AL 103 power charger 30 Vrms not powered by the AL 103 power charger 45 MHz to 2150 MHz 130 dBuV In order to select the supply voltage of the external units press asc 11 key and the screen will display a functions menu labelled EXT SUPPLY listing the choice of voltages which will depend on the band being used Turn the rotary selector 1 to the desired voltage and press to activate it The following table shows the choice of supply voltages Page 30 11 2013 SATELLITE External 13 V 22 kHz 18 V 22 kHz TERRESTRIAL External 5 V 15V Table 3 External units powering voltages In the External power supply mode is the unit powering the amplifiers before the
170. que pour faciliter le pointage d antennes Quand on l active l instrument se configure automatiquement pour offrir un balay tr s rapide de l espectre et une barre graphique de haute sensibilit un calibrage fin des pics de signal Inclut en outre un module pour l alimentation de LNBs et les antennes DVB T 5 V Ainsi que les commandes pour la programmation de dispositifs DiSEqC 1 2 Page 2 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX L EXPLORER permet la mise jour simple aux nouvelles versions de software qui tendrant dans un futur les fonctions disponibles De cette mani re il peut incorporer de nouvelles prestations sans co t additionnel Comme par exemple la v rification des r seaux de distribution de signaux satellite Son utilisation en combinaison avec un g n rateur de FI fait possible une v rification simple des installations avant son d but du service L analyseur de spectre qui incorpore EXPLORER est dot d une extraordinaire pr cision r solution sensibilit et vitesse de balayage donc il devient un instrument tr s utile pour les applications d installation d antennes ou de d tection de complexes ph nom nes de bruit impulsionnel pr sente un innovateur syst me de contr le de la repr sentation au moyen de fl ches de curseur qui rend tr s intuitive l utilisation de la fonction analyseur d espectres Les fl ches permettent d ajuster le niveau de r f rence dans des pas de 10 dB et le span de
171. r downlink at satellite band Channel plan configurable on demand 45 865 MHz 50 kHz 950 2150 MHz lt 200 kHz span FULL 500 200 100 50 32 16 MHz Threshold level selectable DVB T or DVB C selection Analogue and digital Automatic 750 Universal with BNC or F adapter 130 dBuV 50 Vrms powered by the AL 103 power charger 30 Vrms not powered by the AL 103 power charger 130 dBuV DIGITAL SIGNALS MEASUREMENT POWER RANGE COFDM QAM QPSK MEASUREMENTS DVB T COFDM Presentation DVB C QAM Presentation DVB S QPSK Presentation Page 4 45 dByV to 100 dByV 45 dByV to 110 dBuV 44 dByV to 114 dBuV Power CBER VBER MER C N Numeric and level bar Power BER MER C N Numeric and level bar Power CBER VBER MER C N Numeric and level bar 11 2013 USER S MANUAL PRODIG 5 COFDM SIGNAL PARAMETERS Carriers Guard Interval Code Rate Modulation Spectral inversion Hierarchy QAM SIGNAL PARAMETERS Demodulation Symbol rate Roll off a factor of Nyquist filter Spectral inversion QPSK SIGNAL PARAMETERS Symbol rate Roll off a factor of Nyquist filter Code Rate Spectral inversion VIDEO Format Services decoding AXPROMAX 2k 8k Selected by the user 1 4 1 8 1 16 1 32 Selected by the user 1 2 2 3 3 4 5 6 7 8 QPSK 16 QAM 64 QAM Selectable ON OFF Indicates hierarchy mode 16 32 64 128 256 QAM 1000 to 7000 kbauds 0 15 Selectable O
172. r du niveau de bruit 5 14 4 TV num rique Mesure de la Puissance Le PRODIG 5 EXPLORER mesure la puissance du canal dans la largeur de bande du filtre de mesure et estime la puissance totale du canal en consid rant que la densit spectrale est uniforme sur toute la largeur de bande du canal En s lectionnant le mode de mesure PUISSANCE CANAL l information ci dessous apparaitra sur le moniteur DVB T COFDM PUISSANCE 55 8 dBuV Figure 25 Mesure de la puissance de canaux num riques En plus de la puissance du canal num rique 55 8 dBuV dans l exemple de la figure pr c dente la frequence de syntonie ou le canal sera pr sent conform ment au mode de syntonie s lectionn et la fr quence de d placement pour le calcul de la puissance du canal num rique Afin que la mesure de puissance d un canal num rique soit correcte il est indispensable d avoir pr alablement d fini la largeur de bande du canal l aide de la fonction Largeur Canal dans le menu Configuration des Mesures qui appara t en D poussant la touche 17 11 2013 Page 51 AxPROMAX MANUEL D UTILISATION PRODIG 5 5 14 5 TV num rique Mesure du BER Le PRODIG 5 EXPLORER permet de mesurer le taux d erreur BER d une signal num rique de trois formes diff rentes selon le type de modulation employ e Pour s lectionner la mesure du BER 1 Choisir la Configuration des Mesures de signaux num riques en poussant l
173. rada en servicio P gina 2 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX El analizador de espectros que incorpora el EXPLORER destaca por la precisi n resoluci n sensibilidad y velocidad de barrido que le hacen ser muy til para aplicaciones de instalaci n de antenas o detecci n de complejos fen menos de ruido impulsional Presenta un innovador sistema de control de la representaci n mediante flechas de cursor que hace muy intuitiva la utilizaci n de la funci n analizador de espectros Las flechas permiten ajustar el nivel de referencia en pasos de 10 GB y el span del margen de frecuencias en pantalla Para una mayor comodidad de uso dispone de memorias para almacenar adquisiciones de medidas autom ticamente registrando nombre de la adquisici n punto de la medida frecuencia tabla de canales etc La funci n ADQUISICI N facilita enormemente la verificaci n de sistemas donde se requiere realizar un elevado n mero de medidas y posibilita un posterior procesado de toda la informaci n adquirida en un ordenador personal Adem s el equipo incorpora un generador de comandos DiSEqC y permite suministrar diversas tensiones a la unidad externa 5 V 13 V 15 V 18 V 24 V Tambi n se ha provisto al equipo de un EUROCONECTOR o conector Scart con entrada salida de audio v deo El PRODIG 5 se alimenta mediante bater a recargable o conectado a la red mediante el alimentador DC externo suministrado Incorpora un
174. ram tres d tect s automatiquement Taux Viterbi Aussi connu sous le nom de taux de Viterbi Il d finit le taux entre les bits de donn es et le nombre total de bits transmis la diff rence correspond au nombre de bits de contr le pour la d tection et la reprise d erreurs Modulations Modulation employ e par les porteuses Ce param tre d finit aussi Pimmunit de syst me au bruit QPSK 16 QAM et 64 QAM Hi rarchie La norme de DVB T contemple la possibilit pour faire une transmission TDT avec niveaux hi rarchiques c est dire une transmission simultan e du m me programme avec diff rentes qualit s d image et niveaux de protection au bruit de sorte que le r cepteur peut changer un signal de moins qualit quand les conditions de r ception ne sont pas optimales Page 42 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX m Vi gt Ma n PLAN FREQUENCES Figure 19 Ecran de configuration de mesure de signaux modul s en COFDM 5 13 3 Configuration d un Canal Num rique DVB S QPSK D Pousser la touche de configuration de mesures 17 pour acc der au menu de CONFIGURATION et tourner la mollette 1 pour acc der aux param tres relatifs au signal QPSK que peut tablir l utilisateur et qui sont d crits ci dessous 1 Inv Spectrale Inversion de Spectre Si n cessaire activer l inversion de spectre Si l inversion de spectre est s lectionn e de mani re incorrecte la r ception ser
175. repr sent le niveau de signal pour chaque fr quence les fr quences les plus basses tant dans la partie gauche de l cran et les plus lev es droite L amplitude des lobes est calibr e Dans l exemple de la figure pr c dente le niveau de bruit se situe autour de 25 dBuV et le lobe ayant le niveau de signal le plus lev le troisi me a partir de la droite a environ 70 dBuV La marge de fr quences repr sent e que nous appellerons Expansion a partir de maintenant peut aussi tre modifi e l aide des touches de curseur horizontales 6 Ainsi c est possible de choisir la marge de fr quences r pr sent e sur l cran dans le mode Analyseur de Spectre entre Complet toute la bande 500 MHz 200 MHz 100 MHz 50 MHz 32 MHz 16 MHz et 8 MHz ce dernier seulement dans la bande terrestre Page 60 11 2013 MANUEL D UTILISATION PRODIG 5 AXPROMAX Dans la repr sentation du spectre apparait une ligne verticale discontinue que nous appellerons marqueur Cette ligne identifie la fr quence syntonis e Lune des applications du PRODIG 5 comme Analyseur de Spectre consiste rechercher la meilleure orientation et la meilleure situation pour l antenne r ceptrice principalement dans la bande UHF du fait que l on travaille des fr quences lev es et par cons quent avec des longueurs d onde comprises entre 35 et 65 cm En d pla ant de peu de centim tres l antenne le rapport entre les fr quences porteuses d image
176. rithmic scale not linear that is to say the bar divisions correspond to the exponent of the measurement With the aim to have a reference about the signal quality it is considered that a system has a good quality when it decodes less than one non correctable error for every transmission hour This border is known as QEF Quasi Error Free and it corresponds approximately to a BER after Viterbi of 2 0E 4 BER 2 0x1 o that is to say 2 wrong bits of each 10000 This value is marked on the measurement bar of the BER and therefore BER for acceptable signals must be at the left side of this mark Finally it is shown a status line with information about the detected signal The possible messages that can appear and its meaning are showing the following list The messages are exposed from less to more fulfilment of the MPEG 2 standard No signal received No signal has been detected Timing recovered Only it is possible to recuperate the symbol time AFC in lock The system automatic frequency control can identify and lock a digital transmission TDT but its parameters can not be obtained It can be due to a transitory situation previous to the TPS identification Transmission Parameter Signalling or well to a TDT transmission with an insufficient C N ratio TPS in lock The TPS Transmission Parameter Signalling are decoded The TPS are carriers 17 in the 2k system and 68 in the 8k system modulated in DBPSK containing information rel
177. rnant dans le sens des aiguilles d une montre l option active se d place vers le bas alors qu en tournant dans le sens contraire l option active se d place vers le haut EXT VID O T moin lumineux de pr sence de signal de vid o ext rieur Il reste illumin quand le vid o qui est pr sent dans l cran proc dera de la Prise P ritel 35 DRAIN Indicateur lumineux d alimentation des unit s ext rieures S illumine lorsque le courant est fourni l unit ext rieure partir du PRODIG 5 EXPLORER CHARGER Indicateur lumineux de fonctionnement par alimentateur CC externe Dans le cas o les batteries seraient install es l alimentateur de batteries est activ automatiquement SENSOR Capteur de luminosit environnementale permet le calibrage automatique du contraste et la luminosit de l cran en contribuant l conomie de la batterie A Y CURSEURS lls permettent le calibrage dans le mode d op ration Analyseur de Spectre du niveau de r f rence et la marge de fr quences repr senter Expansion Ainsi que le d placement par les diff rents menus et les submenus qui apparaissent dans l cran ECRAN CLAVIER PRINCIPAL 12 touches pour la s lection de fonctions et l entr e de donn es num riques Page 20 11 2013 10 11 12 MANUEL D UTILISATION PRODIG 5 ZXPROMAX 48 to 49 9 ada E Nhl ABC g DEF g GHI 0 KE pise amp A ex MNO PARS TUV W
178. rouve d charg e le temps de recharge avec l appareil teint se situe autour de 5 heures Le t moin lumineux CHARGER 4 doit rester allum Quand le processus de charge de la batterie avec l appareil teint est fini le ventilateur s arr te IMPORTANT Il est souhaitable de conserver l appareil avec la batterie charg e entre 30 et 50 de sa capacit pour les p riodes de non utilisation La batterie dont est dot cet appareil doit tre maintenue en tat de plein chargement pour obtenir le rendement esp r Une batterie compl tement charg e se d charge d elle m me en fonction de la temp rature par exemple a 20 C de temp rature ambiante elle peut avoir perdu jusqu a 10 de son chargement au bout de 12 mois 3 2 Installation et Mise en Marche Le mesureur de champ PRODIG 5 EXPLORER a t con u comme appareil portatif ce pourquoi il ne requiert pas installation En appuyant sur la mollette 1 pendant plus de deux seconds on active la mise en marche de l appareil et celui se met en marche dans la modalit d arr t automatique Apr s un temps d termin sans avoir appuy aucune touche l appareil se d branche automatiquement L arr t automatique peut tre aussi activ avec l appareil en marche au moyen le menu Pr f rences 22 ainsi comme s l ctionner le temps d attente jusqu au d branchement automatique Page 14 11 2013 MANUEL D UTILISATION PRODIG 5 AXPROMAX 4 GUIDE RAPIDE D UTILIS
179. s de chrominance et de son varie substantiellement et par cons quent affecte la qualit de l image sur le r cepteur S il existe un exc s dans la porteuse de son il peut appara tre l cran du t l viseur une perturbation ou un moir du fait des battages de fr quences entre le son la chrominance et les fr quences du syst me vid o lui m me S il existe un d faut de porteuse de chrominance il faut obliger l amplificateur de couleur du t l viseur fonctionner dans des conditions de gain maximum il peut alors se produire un bruit qui se manifestera sur l ensemble de l cran du t l viseur par des points de couleur qui pourront dispara tre en diminuant le contr le de saturation A l extr me il est aussi possible que l on arrive la perte de couleur 5 15 1 Marqueurs Seulement dans le mode analyseur de spectre Le marqueur en couleur rouge indique la fr quence centrale ou la fr quence de syntonie qui peut se d placer en tournant la mollette 1 tant dans le mode de syntonie par canal comme par fr quence 24 Quand on monitorise le spectre de signaux num riques apparaissent aussi deux marqueurs additionnels en couleur blanche qui indiquent le large de bande du canal num rique voir la figure pr c dente 5 16 Visualisation du signal de vid o 1 En poussant la touche 2 depuis toute mode d op ration le PRODIG 5 EXPLORER acc de au mode TV et d module sur l cran le signal de vid o
180. s canaux slots par un seul c ble de descends De cette mani re chaque utilisateur qu utilise un slot peut syntoniser et d coder tout signal pr sent dans le satellite Pour choisir la fonction SATCR pousser la touche DiSEqC 21 du panneau frontal et au moyen de la mollette 1 activer l option SATCR Dans l cran on montre les options de configuration que l utilisateur peut modifier canal choisi nombre de canaux actifs adresse du dispositif passe de fr quence habilitation des pilotes d essai et finalement les fr quences correspondant chaque canal a SATELLITE NI SELECTED SLOT 1 20 IBLV dB Figure 41 Ecran des commandes SatCR En activant l option Habiliter Pilotes le dispositif SatCR situ dans la t te met un signal pilote de niveau constant pour chaque fr quence de descente slot Cette fonction facilite la v rification et l identification des diff rents canaux satellite disponibles dans l installation Cette technologie SatCR est d velopp e au niveau d essais dans divers pays SatCR est une marque d pos e STMicroelectronics Page 66 11 2013 MANUEL D UTILISATION PRODIG 5 AXxPROMAX 5 20 Utilisation du clavier alphanum rique Pour pouvoir introduire des donn es num riques ou texte on dispose d un clavier alphanum rique Beaucoup de touches incorporent un nombre et plusieurs lettres au style des claviers t l phoniques 1 NOTE Introduction de donn es num
181. s son muy diferentes en t rminos del contenido de la se al y de distribuci n de la potencia en el canal Por tanto necesitan ser medidas de forma diferente La relaci n de error de modulaci n MER utilizada en los sistemas digitales es an loga a la medida de Se al Ruido S N en los anal gicos El MER representa la relaci n entre la potencia media de la se al DVB y la potencia media de ruido presente en la constelaci n de las se ales A modo de ejemplo los demoduladores QAM 64 requieren un MER superior a 23 dB para operar Si bien es preferible contar con un margen de al menos 3 4 dB para posibles degradaciones del sistema Mientras los demoduladores QAM 256 requieren un MER superior a 28 dB con m rgenes de al menos 3 dB Habitualmente el valor m ximo de MER visualizable en analizadores port tiles es de aproximadamente 34 dB Por ltimo aparece una l nea de estado que presenta informaci n respecto a la se al detectada Los posibles mensajes que pueden aparecer y su significado se muestra en la siguiente lista Los mensajes se presentan por orden de menor a mayor cumplimiento de los requerimientos del est ndar MPEG 2 Se al no detectada No se ha detectado ninguna se al Se al detectada Se ha detectado una se al pero no es descodificable Portadora recuperada Se ha detectado una portadora digital pero no es descodificable MPEG 2 Detecci n correcta de una se al MPEG 2 5 15 Analizador de Espectros El mod
182. satellite band T This led remains lighted when the equipment works with the frequencies and the corresponding channels to the terrestrial band r D A lt MEASUREMENT CONFIGURATION It allows the commutation between the measurement mode for Digital TV or Analogue TV D This led remains lighted when the equipment works with digital signals A This led remains lighted when the equipment works with analogue signals Le mno IMAGE ADJUST Activation of VOLUME CONTRAST BRIGHT SATURATION and HUE only for NTSC colour system control menus Key number 6 to enter numeric data Page 22 11 2013 21 22 7 DiSEqC pars DISEQC Only in satellite band It allows adjusting configuration parameters in satellite band Key number 7 to enter numeric data 8 tuv UTILITIES PREFERENCES It activates the Utilities menu short pulsation Equipment Info Displays information on the instrument PN product number version of control software included set up etc Attenuation Test Only terrestrial band Selects the function for testing signal distribution networks in terrestrial band Sat IF Test Only satellite band Selects the function for testing signal distribution networks in satellite band Run Datalogger Function to automatically acquire measurements View Datalogger Displays the available acquisition list Erase Dataloggers Deletes an acquisition previously recorded Delete Channel Set Delete
183. screen to the human eye is greater than 35 cm with a viewing angle of 90 between the eye and the screen should not be considered manufacturing defects either It is advisable a viewing angle of 15 in the 6 00 o clock direction in orden to obtain the optimum visualization of the screen 7 2 Cleaning Recommendations CAUTION To clean the cover take care the instrument is disconnected CAUTION Do not use scented hydrocarbons or chlorized solvents Such products may attack the plastics used in the construction of the cover The cover should be cleaned by means of a light solution of detergent and water applied with a soft cloth Dry thoroughly before using the system again CAUTION Do not use for the cleaning of the front panel and particularly the viewfinders alcohol or its derivatives these products can attack the mechanical properties of the materials and diminish their useful time of life 11 2013 Page 69 MANUEL D UTILISATION PRODIG 5 AXxPROMAX SOMMAIRE di G NERALITES i n 1 1 1 Description is 1 2 Sp cifications reinir saran aiana aaea N enea raaa Eae iaraa CENO Aa Ateina raia 4 2 PRESCRIPTIONS DE S CURIT csccssessssssessessessesssecsecsecsessnssuecsecseesesueeneeseeneesees 9 27 Generales oa an anta 9 2 2 Exemples de Cat gories de Surtension ss 11 3 INSTALLATION cuina 13 3 1 AllMeOntatiOn cito in id cadens 13 3 1 1 Fonctionnement avec l alimentateur CC Externe za 18 3 1
184. ted the process will be ready to repeat again for example for a new test point or view measured data by turning the rotary selector 1 or store the information in memory SAVE or exit from this acquisition EXIT 5 10 1 DATALOGGER for Attenuation and IF SAT tests The PRODIG 5 allows to make measurement acquisitions while executing an Attenuation test at terrestrial band or an IF SAT test at satellite band see section 5 11 Verification of distribution networks For it one of these tests should be activated previously as the following figure shows GENE ear Figure 12 Attenuation Test Terrestrial band In order to make the automatic acquisition of these measurements select it from 8 UTILITIES menu by pressing the d 22 key and activating the RUN DATALOGGER option and later the NEW DATALOGGER option In the CHANNEL SET field will appear the type of test that the instrument is going to store automatically 11 2013 Page 35 ZXPROMAX USER S MANUAL PRODIG 5 DATALOGGER R_01 TEST POINT CHANNEL SET FREQ L MHz REF kHz LEVEL CH Figure 13 Datalogger screen for Attenuation test frequencies Once the START option is selected the instrument will capture all test values corresponding to the three pilot frequencies in the active band When measuring is completed it will offer the options to store data or to start a new acquisition FINISHED c TEST POINT F CHANNEL SET FREQ
185. tenant pouss e une touche num rique en mode texte le nombre correspondant sera introduit directement Page 67 AxPROMAX MANUEL D UTILISATION PRODIG 5 6 DESCRIPTION DES ENTR ES ET DES SORTIES 6 1 Entr e de RF L entr e de RF se fait a l aide du connecteur RF 30 sur le panneau lat ral Le niveau maximal du signal ne doit pas tre sup rieur a 130 dBuV 6 2 Port S rie RS 232C Le PRODIG 5 EXPLORER dispose d un port de raccordement s rie RS 232C pour communiquer avec un PC en utilisant le logiciel PKTools ou NetUpdate et ainsi tre capable de r aliser les processus de diagnostic calibrage et configuration Les signaux de ce connecteur sont d crits sur le tableau 4 N 0 Ne Figure 42 Connecteur RS 232C Raccordements vus de face N DE PIN SIGNAL CARACTERISTIQUES 1 Carrier Detect non raccord 2 Data Request RxD 3 Data Transmit TxD 4 Data Terminal Ready DTR non raccord 5 Masse du connecteur GND 6 Data Set Ready DSR non raccord 7 Request To Send RTS 8 Clear To Send CTS 9 Ring Indicator non raccord Tableau 4 Description du connecteur RS 232C Page 68 11 2013 MANUEL D UTILISATION PRODIG 5 ZXPROMAX 6 3 Prise Scart ou P ritel DIN EN 50049 20 1816 141210 8 6 4 2 dd ao Y 2119171513119 7 5 3 1 J Figure 43
186. ternal Voltage Consumption AXPROMAX TFT colour 5 inches PAL SECAM and NTSC M N B G I D Kand L Variable span dynamic range and reference level by means of arrow cursors 40 dBpV for correct synchronism Scart 1 Vpp 75 Q positive video Scart 75 Q Scart Built in speaker Scart TV PAL SECAM NTSC system according to DVB T DVB C DVB S and MPEG standards 50 us Digital frequency synthesis according to the TV standard For service and calibration Through the RF input connector External or 5 13 15 18 24 V Selectable in satellite band 0 6 V0 2 V 22 kHz 4 kHz 5W According to DiSEqC 1 2 standard 7 2 V 11 Ah Li lon battery gt 3 5 hours in continuous mode 3 hours up to 80 instrument off 12V 35 W 8 DiSEqC is a trademark of EUTELSAT 11 2013 Page 7 ZXPROMAX USER S MANUAL PRODIG 5 Auto power off Programmable After the selected amount of minutes without operating on any control Deactivable OPERATING ENVIRONMENTAL CONDITIONS Altitude Up to 2000 m Temperature range From 5 to 40 C Automatic disconnection by excess of temperature Max relative humidity 80 up to 31 C decreasing lineally up to 50 at 40 C MECHANICAL FEATURES Dimensions 230 W x 161 H x 76 D mm Total size 2 814 cm Weight 1 9 kg without holster INCLUDED ACCESSORIES 1x CB 077 Rechargeable Li battery 7 2 V 11 Ah 1x AT 010 10 dB attenuator 1x AD 055 F F B
187. the channel plan selected Delete Channels Delete a channel from the active channel plan Insert Channels Add a channel to the current channel plan from another standard list of channels Exit Exit from Utilities It activates the Preferences menu long pulsation Language Selects the language between DEUTSCH ENGLISH ESPANOL FRAN AIS ITALIANO and PYCCKWM Beep Activates ON deactivates OFF the beeper 11 2013 Page 23 AxPROMAX Skin Light Sensor Ter Identify Min Ter Power Min Ter Level Min Sat Power C N Identify Timeout Sat Band Auto Power Off Time Power Off Units Rotary Selector Exit USER S MANUAL PRODIG 5 Sets the screen background colour lt activates a light sensor to automatically adjust the display contrast and brightness Options are High contrast with low luminosity Low contrast with high luminosity and AUTO Selects the type of terrestrial digital signal DVB C or DVB T used by AUTO ID and EXPLORER functions Minimum level of digital signal to display Between 0 0 dBuV and 130 0 dBuV Minimum level of analogue signal to display Between 0 0 dBuV and 130 0 dBuV Minimum level of digital signal to display Defines the C N measuring method between Auto or Reference Noise Manual used to determine the frequency where noise level will be measured in the spectrum analyser mode Sets the maximum time that the equipment will carry out the identif
188. ting 1 GENERALITES 1 1 Description L explorateur de t l vision PRODIG 5 EXPLORER repr sente un pas volutif par rapport aux mesureurs de champ traditionnels PROMAX continue avec l innovation dans le secteur des mesureurs de champ en pr sentant un appareil qu il change la m thode de faire et comprendre les mesures des signaux de t l vision Cet appareil incorpore d importantes avances tant dans les aspects fonctionnels comme dans l ergonomie pour permettre aux installateurs d effectuer leur travail avec le maximal confort et vitesse A la fois l instrument s av re fiable devant tout possible probl me du signal d entr e dans les composants de distribution ou dans les appareils de r ception Le PRODIG 5 a t concu pour satisfaire toutes les n cessit s de mesure pendant la transition des transmissions analogiques aux num riques dans les syst mes terrestres satellites et par cable Permet d effectuer mesures de signaux analogiques et num riques En activant la fonction d identification automatique en poussant une seule touche l appareil essaye d identifier le signal en test D abord examine s il s agit d un canal analogique ou num rique Si le canal est analogique il d termine le type de standard du signal d tect Si est num rique DVB analyse pour chaque type de modulation QAM QPSK COFDM tous les param tres associ s porteuses 2k 8k symbol rate code rate etc et d termine les valeurs dans le signal
189. tion sisi 63 5 18 DiSEqC Command Generator 64 5 19 SATCR function 66 5 20 Using the alphanumeric keyboard ss 66 6 DESCRIPTION OF THE INPUTS AND OUTPUTS escenes 67 Gil SRR AMPUs sen cnrs sue issecacdtekvesutcctectadassutacs cotapisivsstnaacssaceieais sudsesceteais satsessead 67 6 2 RS 282C Serial Pottsin ae anao araa A ara aea aA AEREE Eaa TEREE nA 67 6 9 Scan DIN EN 50049 cocino ibi 68 7 MAINTENANCE constancias 7 1 Considerations about the Screen ss 7 2 Cleaning Recommendations occoccicnnnnnnnnnnnnincnnnnnnn can nrncrnar anna carac UNIVERSAL TV EXPLORER PRODIG 5 Digital Video Broadcasting 1 GENERAL 1 1 Description The television explorer PRODIG 5 EXPLORER represents an evolutionary step with respect to the traditional field strength meters The continuous PROMAX innovation process in the sector of field strength meter yields an instrument that changes the way to take and understand television signals measurements This equipment incorporates important advances in the functional aspects as well as in the ergonomics to allow the installers to make their work with maximum comfort and speed Simultaneously the instrument is reliable for any possible problem at the input signal at the distribution components or the receiver equipment The PRODIG 5 has been designed to satisfy all the necessities of measurement during the transition from the analogue transmissions to digital in terrestrial satel
190. tion E 17 key to access to the CONFIGURATION menu and turn the rotary selector 1 to access the QPSK signals parameters which can be defined by user and are described below 1 2 3 Spectral Inv If necessary activate the Spectral inversion On Reception will be bad if spectral inversion has been incorrectly selected Code Rate Also known as Viterbi ratio It defines the ratio between the number of data bits and actual transmission bits the difference corresponds to the control bits for error detection and correction It permits to choose between 1 2 2 3 3 4 5 6 and 7 8 Symbol Rate It is possible to choose between the following values from 2000 to 45000 kbauds When selecting the option appears the current value in order to modify it enter a new value through keyboard when appears the data enter symbol appears on the upper left corner screen Page 42 11 2013 4 5 6 7 SIGNAL Figure 20 Screen of mesurement configuration QPSK signals Polarization It affects to the signal reception in the SAT band satellite It allows to select the the signal polarisation among Vertical Right vertical and circular clockwise and Horizontal Left horizontal and circular counterclockwise or to deactivate the polarization OFF Sat Band Selects the High or Low frequency band for satellite channel tuning LNB Low Osc Sets the LNB low band local oscillator LNB High Osc Sets the LNB hig
191. tonie de canaux num riques DVB peut exiger une mise au point Il est recommand de suivre la proc dure indiqu e ci dessous 4 MWh Depuis le mode Analyseur de Spectre sw 13 syntoniser le canal dans sa fr quence centrale 3 ET Passer au mode Mesures 12 s lection des mesures Si le message MPEG 2 n appara t pas dans la ligne inf rieure de l cran et par cons quent le taux d erreur est inacceptable en tournant la mollette d vier la fr quence de syntonie jusqu l apparition du message Enfin re syntoniser le canal pour minimiser loffset de syntonie qui optimise le BER et par cons quent minimiser le BER Si Pon ne parvient a d tecter aucun canal MPEG 2 s assurer que les param tres du signal num rique sont bien corrects 5 14 S lection des Mesures Les mesures disponibles d pendent de la bande de fr quences d op ration terrestre ou satellite et du type de signal analogique ou num rique Bande terrestre Canaux analogiques Niveau Mesure de niveau de la porteuse syntonis e Vid o Audio Relation entre les niveaux de la porteuse de vid o porteuse d audio C N Relation entre la puissance du signal modul et la puissance de bruit quivalent pour la m me large de bande Bande terrestre Canaux numeriques DVB C et DVB T Puissance Canal La puissance du canal est mesur e en consid rant que la densit spectrale de puissance est uniforme sur toute la largeur de bande du
192. tor rotativo 1 seleccionar el valor deseado y finalmente pulsarlo de nuevo para validarlo 2 Intervalo Guarda El par metro Intervalo de Guarda corresponde al tiempo muerto entre s mbolos su finalidad es permitir una detecci n correcta en situaciones de ecos por multi camino Este par metro se expresa en funci n de la duraci n del s mbolo 1 4 1 8 1 16 1 32 Para definir su valor girando el selector rotativo 1 posicionar el cursor sobre el campo Guarda y entonces pulsarlo Entonces girando el selector rotativo 1 seleccionar el nuevo valor y finalmente pulsarlo para validar 3 Ancho de Banda Ancho de banda del canal Permite seleccionar el ancho de banda de los canales entre 8 MHz 7 MHz y 6 MHz La selecci n de este par metro es imprescindible para el correcto funcionamiento del sintonizador debido a que afecta a la separaci n en frecuencia de las portadoras 11 2013 P gina 41 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 4 Inv Espectral Inversi n espectral Esta opci n permite aplicar una inversi n espectral a la se al de entrada aunque en la mayor a de los casos debe estar en OFF no inversi n Este men de configuraci n muestra adem s de los par metros de la se al COFDM seleccionables por el usuario los valores de los par metros detectados autom ticamente Tasa de C digo Tambi n conocido como relaci n de Viterbi Define la relaci n entre el n mero de bits de datos y el n mero de bits tota
193. trada de se al de RF Nivel m ximo 130 dBuV Conector universal para adaptador F F o F BNC con impedancia de entrada de 75 Q ATENCI N A Utilizar el atenuador de 10 dB AT 010 para proteger la entrada RF 30 cuando el nivel de la se al de entrada supere 130 dB N 1 V o existan sospechas de problemas de intermodulaci n Este accesorio permite el paso de tensi n continua para alimentaci n de unidades exteriores LNB y amplificadores Figura 6 Conexi n del atenuador externo en la entrada RF 30 P gina 26 11 2013 31 32 33 34 85 36 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX ATENCI N A Es necesario destacar la necesidad de proteger la entrada RF gt 30 con un accesorio que elimine las tensiones alternas de alimentaci n que se utilizan en los CATV necesarios para alimentar los amplificadores y en control remoto a 8 6 6 Figura 7 Elementos del panel lateral Pulsador de RESET Permite reiniciar el equipo en caso de anomal a en su funcionamiento Entrada de alimentaci n externa de 12 V Altavoz Ventilador Euroconector Enganche para cinta de transporte 11 2013 P gina 27 AxPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 Figura 8 Vista panel posterior 37 Conector RS 232C Para operaciones de mantenimiento y calibraci n 5 2 Ajuste de los Par metros del Monitor y del Volumen 6 La
194. tte marque 11 2013 Page 57 AxPROMAX MANUEL D UTILISATION PRODIG 5 Au bas de la fr quence ou canal de syntonie on montre la d viation de fr quence en kHz par rapport a la fr quence de syntonie qui optimise le BER par exemple Freq 1777 000 MHz 1 2 kHz Derni rement il apparait une ligne d tat que pr sente d information en rapport avec le signal d tect Les possibles messages qui peuvent apparaitre et leur signification se montrent dans la liste suivante dans laquelle on pr sente les diff rents messages par ordre du plus petit au plus grand accomplissement des param tres du standard MPEG 2 Aucun signal On n a d tect aucun signal Signal d tect On a d tect un signal mais il n est pas d codificable Porteuse d tect On a d tect une porteuse num rique mais elle n est pas d codificable Viterbi synchronized D tection d une porteuse num rique et synchronisation de l algorithme de Viterbi mais trop de trames arrivent avec d erreurs qui ne sont pas corrigibles On ne peut pas quantifier le BER MPEG 2 D tection correcte d un signal MPEG 2 5 14 6 TV Num rique Mesure du MER Apr s avoir tabli les param tres les param tres de r ception appropri s pour le signal COFDM QAM ou QPSK il sera possible de mesurer le MER pousser la touche ser 12 jusqu ce qu apparaisse l cran de mesure du MER ll DVB T COFDM MER 19 5 dB me 5 08 30 Figure 34 cran de mesur
195. u nm 13 pour monitorer l espectre correspondant NOTE Dans le cas qu on souhaite explorer ou identifier des signaux DVB C est 8 n cessaire d acc der pr alablement au menu de PREFERENCES ruv 22 et de choisir comme Identificateur de signaux num riques terrestres le standard DVB C Page 16 11 2013 MANUEL D UTILISATION PRODIG 5 AXAPROMAX PAS 5 Pour faire des mesures 0 1 Choisir le canal ou la fr quence 24 mesurer au moyen de la mollette 1 3 2 Pousser la touche de s lection du type de mesure ce 12 jusqu ce qu apparaisse l cran correspondant la mesure qu on souhaite obtenir PAS 6 Pour monitorer le spectre de fr quences 5 Ss 1 Choisir la bande de fr quences repr senter E 14 terrestre ou satellite 4 Dalla 2 Activer le balayage en poussant la touche sw 13 de 3 Pousser B 6 pour modifier le niveau de r f rence dans l axe vertical A a 4 Pousser 6 pour modifier le span dans l axe horizontal PAS 7 Pour visualiser le signal de vid o 5 Ss 1 Choisir la bande de fr quences terrestre a 14 0 2 Syntoniser le canal ou la fr quence 24 qu on souhaite visualiser sur l cran 3 3 V rifier que l appareil re oit un niveau de signal appropri 5er 12 1 a 4 Pousser 10 pour visualiser l image de TV si le canal est num rique pousser A d W 6 et situer le curseur sur le champ Identificateur de Service pousser l
196. ulators require a MER greater than 28 dB with margins of al least 3 dB Normally the maximum MER value seen in portable analysers is of approximately 34 dB Finally it is shown a status line which displays information about the detected signal The possible messages that can appear and its meaning are shown in the following list The messages are exposed from less to more fulfilment of the MPEG 2 standard No signal received Any signal has been detected Signal received A signal is detected but it can not be decoded Carrier recovered A digital carrier has been detected but it can not be decoded MPEG 2 Correct detection of a MPEG 2 signal 5 15 Spectrum Analyser The Spectrum Analyser mode allows the user to discover the signals present in the frequency band in quickly and easily and to make measurements at the same time 4 To select it press Ah 13 key The monitor will show a picture like the one described in the next figure 11 2013 Page 59 AxPROMAX USER S MANUAL PRODIG 5 2 I l l Figure 35 Spectrum analyser mode The horizontal lines define the signal level the broken lines being separated a distance equals to 10 dB The level of the top line 70 dBuV in previous figure named Reference Level can be altered using the vertical cursors 6 keys between a range of 60 dBuV to 130 dBuV by steps of 10 dB from 70 dBuV to 130 dBpV in satellite band The signal level for each frequency is displayed
197. xD 3 Data Transmit TxD 4 Data Terminal Ready DTR no conectado 5 Masa del conector GND 6 Data Set Ready DSR no conectado 7 Request To Send RTS 8 Clear To Send CTS 9 Ring Indicator no conectado Tabla 4 Descripci n del conector RS 232C 11 2013 P gina 69 AXPROMAX MANUAL DE INSTRUCCIONES PRODIG 5 6 3 Euroconector DIN EN 50049 20 18 16 141210 8 6 4 2 2119171513119 7 5 3 1 Figura 43 Euroconector vista exterior N DE PIN SENAL CARACTERISTICAS 1 Salida audio canal derecho 2 Entrada audio canal derecho 3 Salida audio canal izquierdo 4 Masa audio 5 Masa Azul B 6 Entrada audio canal izquierdo 7 Salida Azul B 8 Tensi n de conmutaci n 9 Masa Verde G 10 Interfaz bus digital no conectado 11 Salida Verde G 12 Interfaz bus digital no conectado 13 Masa Rojo R 14 Reservado bus digital no conectado 15 Salida Rojo R 16 Se al borrado no conectado 17 Masa v deo compuesto 18 Retorno borrado no conectado 19 Salida v deo compuesto 20 Entrada v deo 21 Masa blindaje conector Tabla 5 Descripci n del Euroconector Para seleccionar el modo de funcionamiento del conector SCART entre Entrada de v deo Salida de v deo o Autom tico desde el modo de visualizaci n de TV 10 seguir los siguientes pasos 1 Seleccionar el men de Configuraci n de Medidas pulsando la tecla D 17
198. y charge status BATTERY CHARGE STATUS RED YELLOW GREEN Table 1 Indication of the battery charge status CHARGER 3 1 2 Operation using the Battery For the device to operate on the battery disconnect the power cable and press the rotary selector 1 for more than two seconds The fully charged battery can power the equipment for more than 3 5 hours non stop If battery is very weak the battery cut off circuit will prevent the device from functioning In such a situation battery must be recharged immediately Before taking any measurements you have to check the charge status of the battery by checking the battery charge level indicator that appears when activating the ET ED measurement mode pressing key 12 These are the indicators on screen 11 2013 Page 13 AXPROMAX USER S MANUAL PRODIG 5 BATTERY CHARGE LEVEL INDICATORS COLOUR SYMBOL CHARGE LEVEL GREEN 75 100 YELLOW 30 75 RED 10 30 lt 10 Charge in progress Table 2 Indication of the battery charge level on screen 3 1 2 1 Battery Charging To fully charge the battery connect the instrument to the external DC charger without activating the power on process The length of time it takes to recharge it depends on the condition of the battery If they are very low the recharging period is about 5 hours The CHARGER 4 indicator should remain lit When the battery charging process
199. y girar el selector rotativo 1 para acceder a los par metros relativos a la se al QAM que puede establecer el usuario y que se describen a continuaci n 1 Modulaci n Define el tipo de modulaci n Al seleccionar esta funci n y pulsar el selector rotativo 1 aparece un men mediante el cual es posible seleccionar una de las siguientes modulaciones 16 32 64 128 y 256 2 Symbol Rate Velocidad de s mbolo Al seleccionar esta funci n y pulsar el selector rotativo 1 aparece un men sobre el que es posible seleccionar un valor de velocidad de s mbolo 3 Inv Espectral Si es necesario activar la inversi n de espectro On Si se selecciona incorrectamente la inversi n de espectro la recepci n no ser correcta P gina 40 11 2013 MANUAL DE INSTRUCCIONES PRODIG 5 AXxPROMAX N D _F AR M Figura 18 Pantalla de configuraci n de medida de se ales moduladas en QAM 5 13 2 Configuraci n de un Canal Digital DVB T COFDM D Pulsar la tecla de configuraci n de medidas 17 para acceder al menu de CONFIGURACION y girar el selector rotativo 1 para acceder a los parametros relativos a la se al COFDM que puede establecer el usuario y que se describen a continuaci n 1 Portadoras N mero de portadoras Define el n mero de portadoras de la modulaci n entre 2k 8k Para modificar su valor girar el selector rotativo hasta posicionar el cursor sobre el campo Portadoras y entonces pulsarlo Girando el selec
Download Pdf Manuals
Related Search
PRODIG 5 prodigy 5e prodigy 5 speakers prodigy 5th grade prodigy 500 plastic prodigy 52800 prodigy 5 inch holster prodigy 5 niche wheels prodigy 5e class - d\u0026d wiki prodigy 5 inch comp prodigy 5 inch prodigy 5 1911 prodigy 500 prodigy 5e feat prodigy 5 review prodigy 52800 test strips
Related Contents
Responsive Banner Slider with Lazy Load Extension By MageBees Utilisation et surveillance d`une pompe à PCA de type pharmacia Linksys WUSB54G User's Manual Serial Port Adapter Integral IN1T1GRQWBX1 memory module SERVICE MANUAL PROGRAMMING MANUAL “ BRIO 250 ” RelacaoItens15303305000232015000 Maris Tshape FGB906ISAC FR(3.36 MB, PDF) USER`S MANUAL AND INSTRUCTIONS Copyright © All rights reserved.