Home
PriorSpec™ II - Prior Scientific, Inc.
Contents
1. batteries should be installed in the PriorSpec II Two alkaline batteries are located within the body of 4 Low Battery x the microscope They can be accessed by releasing the Warning Light cover screw 2 and lifting the battery cover 1 The 2 3 Ribbon ribbon 3 is to aid battery removal 2 Cover Screw Spare parts G425 10x Widefield Eyepiece W387A 20x Widefield Eyepiece W436F 10x to 20x Zoom Eyepiece G00000 PriorSpec II body only W2650 Replacement Carry Case G999 2 5mm Universal Adaptor Service repair of the microscope The PriorSpec II has been designed with minimal maintenance in mind However please contact Prior s Sales Office if you require any specific advice on servicing or on the use of the microscope 5 PriorSpec II Mode d emploi Le PriorSpec II est un microscope portable d di l inspection des faces optiques de connecteurs L instrument est petit et compact et peut tre mis rudes preuves puisqu il a t sp cialement con u pour l utilisation sur le terrain II propose un grossissement 200 ou 400 par un simple changement de l oculaire sur le microscope L clairage incident provient d une source lumineuse de type diode electro luminescente del l int rieur du microscope lui m me et sa dur e de vie est d environ 10000 heures L clairage DEL est aliment par 2 piles alkalines MV qui permettent une utilisation en continu d environ 70
2. heures des piles rechargeables peuvent aussi tre utilis es Un filtre protecteur type KG3 fait partie int grante du syst me optique II emp che les rayons laser de venir en contact avec l oeil de l op rateur Longueur d onde Densit Optique Att nuation nm OD dB 850 20 20 1300 5 0 50 1550 40 40 Important ne jamais inspecter une fibre nue avec le PriorSpec II Plusieurs adaptateurs sont fournis avec le microscope 5 permettent d utiliser la plupart des connecteurs standard de fiches disponibles sur le march actuel L adaptateur s enclenche sur le support pr vu cet effet l avant du microscope Si le microscope venait tomber la bague de s curit qui retient l adaptateur se s parerait automatiquement du microscope Contenu des Kits Plusieurs configurations son G00200 G00201 300400 300401 300000 2x 2x 2x 2x 2x PriorSpec 2 es al PriorSpec es al PriorSpec 5 es al PriorSpec 2 es al PriorSpec 5 es al alines inc alines et alines inc alines et alines inc Pour app ications in possibles grossissemen ues grossissemen pochet grossissemen ues grossissemen pochet ues 200x avec oculaire 10x object 200x avec oculaire 10x object 400x avec oculaire 20x object 400x avec oculaire 20x object sans oculaire objectif 20x grateurs tte de protect
3. 5 Cover Retaining Screw Mechanism Note Under no circumstances should 2 live fiber be inspected with the PriorSpec II Maintenance Eyepieces and Objectives High quality scientific optics are used in the PriorSpec Il The lenses are coated with an anti reflecting layer and they should only be cleaned by wiping with a suitable lens cleaning tissue Vigorous rubbing or the use of a cloth may impair the efficiency of the instrument Changing the Eyepiece The PriorSpec II G00200 G00201 comes complete with a 10x eyepiece G425 as standard providing a total magnification of 200x This 10x eyepiece can easily be replaced with a 20x eyepiece W387A in order to change the total magnification to 400x Similarly the magnification of the G00400 G00401 can be reduced from 400x to 200x magnification by the substitution of the 20x eyepiece with a 10x eyepiece A 10x to 20x zoom eyepiece is also available W436F Procedure Undo the set screw on the eyepiece with a 1 25mm hexagon Allen key Remove the eyepiece and insert the eyepiece replacement into the tube and tighten up the set screw Illumination The LED has a life of approximately 10 000 hours Replacement of the LED should only be undertaken by a Prior trained service engineer Battery Operation The Low Battery Warning Light 4 will illuminate after approximately 70 hours of continuous use indicating that the batteries are nearly exhausted This means that new
4. Indicateur Faible D Energie changer il suffit de d visser 2 et soulever le couvercle 1 gr ce au ruban 3 pr vu cet effet 3 Ruban 2 Verrouillage du couvercle Pi ces D tach es G425 Oculaire a grand champ 10x standard W387A Oculaire grand champ 20x standard W436 Oculaire zoom 10 20x G999 Adaptateur universel 2 5mm standard W2650 Pochette de protection du microscope en toile Entretien Service Apr s Vente du Microscope Le PriorSpec Il n a besoin que d un entretien minimum afin d assurer son bon fonctionnement Contacter le service commercial pour plus d informations techniques sur l entretien ou l utilisation du microscope For more information on Prior products visit our web site at www prior com Specifications subject to change without notification Part No W2568 Issue 1 1 01 01 CERTIFICATE NO FM 61600 STANDARD BS EN ISO 9001 2000 PRIOR SCIENTIFIC INSTRUMENTS LIMITED 3 4 FIELDING INDUSTRIAL ESTATE WILBRAHAM ROAD FULBOURN CAMBRIDGE CBI 5ET TELEPHONE 01223 881711 Fax 01223 881710 PRIOR SCIENTIFIC INC 80 RESERVOIR PARK DRIVE ROCKLAND MA 02370 1062 TELEPHONE 781 878 8442 Fax 781 878 8736 VISIT PRIOR ON THE WEB AT www prior com Specifications subject to change without notice 89STM ON LYWd
5. PriorS pec II PRIOR Scientific Fiber Optic Inspection Microscope Operating Instructions Serial M umber W avelength nm Attenuation dB Minimum Specification Measured Value 850 20 1300 50 1550 40 Signature Introduction The PriorSpec II is a hand held fiber optic inspection microscope used for the examination of optical fiber terminations The instrument is robust and compact and has been designed specifically for use in the field The PriorSpec II offers dual magnification of 200x and 400x by changing the eyepiece in the microscope Incident illumination of the optical fiber termination is provided by an integral Light Emitting Diode LED with a life of approximately 10 000 hours The LED is powered by 2 AA alkaline batteries which provide approximately seventy hours continuous use Rechargeable batteries may be used if required Safety A laser barrier filter is built into the optical system to attenuate laser light which may accidentally enter the system Wavelength Optical Density Attenuation mm OD dB 850 2 0 20 1300 5 0 50 1550 4 0 40 Note Under no circumstances should a live fiber be inspected with the PriorSpec II A number of adapters are available to suit popular connectors and these snap into the adapter ring on the microscope The adapters are retained by spring loaded balls If the microscope is dropped the ad
6. apter will disengage Package Contents The PriorSpec II can be supplied in a number of configurations Some of the most popular configurations are as follows 300200 PriorSpec 200x magnification with 10x eyepiece 20x objective Complete with 2 x AA batteries G00201 PriorSpec II 200x magnification with 10x eyepiece 20 objective Complete with 2 x AA batteries amp carry case 300400 PriorSpec 400x magnification with 20X eyepiece 20X objective Complete with 2 x AA batteries G00401 PriorSpec II 400x magnification with 20x eyepiece 20 objective Complete with 2 x AA batteries amp carry case 300000 PriorSpec II with NO eyepiece 20x objective Complete with 2 x AA batteries For O E M applications Operation To operate Select the appropriate adapter and attach the connector to the adapter 2 Switch Insert the adapter into the centring mechanism 6 and 1 Focus Knob centre if required ensuring that it is firmly seated against LAS the adapter ring face While looking through the eyepiece 7 Adaptor 3 and illuminating the termination by pressing the switch 2 focus the image by turning the knob 1 Once the re LES focus has been set only minimal adjustment to the focus Cover gt gt knob or the centring mechanism will be needed when changing the connectors or adapters 3 Eyepiece 6 Centring
7. ion en toile inclues tif 20x tif 20x tif 20x tif 20x tte de protection en toile inclues Utilisation La mise en marche de l appareil se fait de la mani re suivante 2 Interrupteur marche arr t S lectionner l adaptateur et enclencher le connecteur Molette de mise dans l adaptateur au point Ins rer l adaptateur dans le m chanisme du centrage de Th l appareil puis centrer si n cessaire 6 en s assurant que gt a 9 la partie m tallique de l adaptateur soit bien enclench e Observer le connecteur travers l oculaire 3 en pressant l interrupteur marche arr t 2 qui d clenchera 5 Verrouillage du couvercle 6 te d automatiquement l clairage du microscope Faire ensuite la mise au point finale de l image en tournant doucement la molette pr vue cet effet 1 Une fois la mise au point effectu e l appareil est pr t l utilisation Un changement de connecteurs ou d adaptateurs n cessitera peut tre quelques l gers r glages de mise au point ou de centrage Important ne jamais inspecter une fibre nue avec le PriorSpec Il Entretien Oculaires et objectifs Les optiques du microscope PriorSpec II sont de tr s bonne qualit Les lentilles sont trait es avec une couche sp ciale anti r flechissante et de ce fait elles doivent tre nettoy es avec un papier sp cial pour lentilles objectifs ll est d conseill de frotter les lentil
8. les avec tout autre papier ou chiffon car la performance de l instrument en serait affaiblie Changer l oculaire Le PriorSpec ref G00200 G00201 est fourni avec un oculaire 10x ref G425 permettant ainsi un grossissement total de 200x Afin d obtenir un grossissement de 400 il suffit simplement d interchanger l oculaire 10x avec un oculaire 20x ref W387A De m me sur un mod le G00400 G00401 la r duction du grossissement de 400 200 s obtient en changeant l oculaire 20X par un oculaire 10x Un oculaire zoom 10 20x est aussi disponible ref W436F Proc dure D faire la petite visse sur l oculaire avec une cl Allen 1 25mm Retirer l oculaire et ins rer celle de rechange dans le tube Ress rer la visse Eclairage La dur e de vie du syst me d clairage DEL diode electro luminescente est d environ 10000 heures Ce type d clairage ne pourra tre remplac que dans nos ateliers Fulbourn par un ing nieur technicien form par Prior Scientific Remplacement des piles gt Apr s environ 70 d utilisation en continu un indicateur MDX 6 4 2 faible nergie 4 s allume indiquant que les piles 1 Logement 4 des piles doivent tre chang es assez rapidement LIN Camere P NaF de protection Deux piles de type alcaline AA se logent sur le c t de l appareil sous le couvercle de protection Afin de les 4
Download Pdf Manuals
Related Search
Related Contents
Q - ソニー製品情報 Français - Graphic Communications xtreme value tower series (xvt) user`s manual H301-NIKON-NZ100-200-500-N FICHA TECNICA DEL PRODUCTO Copyright © All rights reserved.
Failed to retrieve file