1. hu Figure 8 IMPORTANT NOTES If you are installing this AP430SS Scale Inhibition System on the cold water line feeding a water heater which already has a build up of scale you may have loosened scale which could go downstream to clog valve and aerators In this case a Stainless Steel Hot Water Sediment and Rust Filter should be installed on the hot water side of the heater to help trap and contain this scale Water Heater or Tankless System AP430SS Scale Inhibition System Aqua Pure Model SST1HA with AP2005 Stainless Steel Sediment and Rust Water Filter optional REPLACEMENT PARTS Head 6838732 O Ring 7205738 Cartridge AP431 LIMITED WARRANTY Limited Warranty 3M Purification Inc warrants the stainless steel head excluding disposable cartridge s to be free from defects in material and workmanship for twenty five 25 years from the date of purchase The disposable cartridge is warranted from defects in material and workmanship for a period of one 1 year from the date of purchase This war ranty does not cover failures resulting from abuse misuse alteration or damage not caused by 3M Purification Inc or failure to follow installation and use instructions No warranty is given as to the service life of any cartridge as it will vary with local water conditions and water consumption 3M PURI
2. Pour r duire le risque de fuite d eau ou d inondation et pour garantir une filtr tion optimale e La cartouche jetable doit tre remplac e au moins tous les 6 mois gt e Le non remplacement de la cartouche filtrante jetable aux fr quences indiqu es est susceptible d engendrer une r duction de la filtration et des fissures sur le bo tier du filtre entra nant des fuites ou une inondation Conserver toujours des cartouches de rechange en r serve 1 Fermer les valves d entr e robinet de d charge et de sortie robinet vanne Pour rel cher la pression dans le syst me AP430SS ouvrir le drain de la valve d entr e 2 D visser la cartouche AP431 en la tournant vers la gauche tel qu illustr figure 8 3 Installer la nouvelle cartouche et resserrer mod r ment la main Ne jamais utiliser d outils pour resserrer la cartouche LL 4 Ouvrir la soupape d alimentation et vacuer l air par le dispositif de vidange du robinet vanne jusqu ce l arriv e de l eau Refermer le robinet de vidange et ouvrir la sortie d eau Figure 8 REMARQUES IMPORTANTES Si ce syst me inhibiteur d entartrage AP430SS est install sur une canalisation d eau froide alimentant un chauffe eau qui contient d j des d p ts de tartre il est possible que du tartre se d tache et circule en aval pour bloquer les soupa pes et brise jet En de tels cas il e
3. Installation and Operating Instructions For Scale Inhibition System Model AP430SS SAFETY INFORMATION Read understand and follow all safety information contained in these instructions prior to installation and use of the Scale Inhibition System Model AP430SS Retain these instructions for future reference Intended use The Scale Inhibition System Model AP430SS is intended for use in treatment of potable water and has not been evaluated for other uses The product is installed at the point of entry main distribution pipe and must be installed as specified in the installation instruction by a qualified professional EXPLANATION OF SIGNAL WORD CONSEQUENCES Indicates a potentially hazardous situation which if not avoided could result in A WARNING death or serious injury and or property damage N OT C E Indicates a potentially hazardous situation which if not avoided may result in property damage A WARNING To reduce the risk associated with choking e Do not allow children under 3 years of age to have access to small parts during the installation of this product To reduce the risk associated with ingestion of contaminants e Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system To reduce the risk of physical injury e Depressurize system as shown in manual prior to cartridge removal NOTICE To reduce the risk associated with property dam
4. La instalaci n y la utilizaci n DEBEN cumplir con todas las normas de plomer a estatales y locales No utilice sellador de roscas ni grasa para roscas en accesorios pl sticos Utilice Tuerca del nicamente cinta para roscas de PTFE Las propiedades de la grasa para roscas desag e pueden deteriorar el pl stico No utilice linternas ni otras fuentes de calor cerca del sistema de filtrado accesorios o piezas pl sticas de plomer a ni cartuchos Aseg rese de que el lugar y los sujetadores soporten el peso del sistema Aseg rese de que todos los tubos y accesorios est n fijos y no tengan p rdidas Hacia el calentador de agua CORTE EL SUMINISTRO ELECTRICO O A COMBUSTION DEL CALENTADOR RSS DE AGUA DESPUES DE INTERRUMPIR EL SUMINISTRO DE AGUA Figura 3 4 Mediante el conector a compresi n de la v lvula conecte la v lvula de com puerta al tubo de entrada de suministro de agua posterior al sistema Ajuste firmemente la tuerca de compresi n Figura 4 NOTAS IMPORTANTES Puede surgir la necesidad de separar un poco los extremos de los tubos para insertar el ensamblaje de la cabeza AP430SS con adaptadores en la v lvula Hacia el calentador de agua 5 Ajuste firmemente todas las tuercas de compresi n manteniendo el ensamblaje Figura 4 de la cabeza AP430SS en posici n vertical Figura 5 6 Gire el cartucho hacia la derecha para enroscarlo en la cabeza del filtro AP430SS Abra el
5. une pompe de suralimentation est install e sur un syst me de distribution d eau vous devez installer une soupape de d charge de pression adapt e La soupape de d charge de pression doit tre entretenue et contr l e tous les six mois Communiquez avec un plombier professionnel pour toute incertitude concernant le choix l installation ou l entretien d une soupape de d charge de pression Lorsque qu une pompe de suralimentation est install e sur un r seau d alimentation en eau vous devez installer une vanne de r gulation de la pression et r guler la pression de l eau jusqu 80 psi Communiquez avec un plombier professionnel pour toute incertitude concernant le choix l installation ou l entretien d une vanne de r gulation de la Pour r duire le risque de fuite d eau ou d inondation et pour garantir une filtration optimale e Changez la cartouche filtrante jetable tous les six 6 mois ou plus t t en cas de r duction notable du d bit de l eau e Le non remplacement de la cartouche filtrante jetable aux fr quences indiqu es est susceptible d engendrer une r duction de la filtration et des fissures sur le bo tier du filtre entra nant des fuites ou une inondation e Pour toute question ou tout doute merci de communiquer avec le Service client le au 1 800 222 7880 REMARQUES IMPORTANTES e Ne pas se conformer ces directives pourrait annuler la garantie e Laisser un espace libre d au moins 5 1 cm 2 po sou
6. viter la d t rioration du plastique occasionn par Penduit d enrobage Utiliser soigneusement les pinces ou les cl s tuyau pour serrer les adaptateurs pour viter tout dommage occasionn par un serrage excessif Ne pas installer directement sous les rayons solaires ou l ext rieure Fixer le syst me de mani re viter les chocs provoqu s par d autres articles utilis s dans la zone d installation S assurer que l emplacement et les pi ces de fixation supportent le poids du syst me lorsqu il est install et rempli d eau S assurer que toute la tuyauterie et les adaptateurs sont s curis s et exempts de fuites METTRE LA SOURCE D ALIMENTATION OU D ESSENCE DU CHAUFFE EAU HORS TENSION apr s avoir coup l eau e Lorsqu un dispositif de pr vention de retour d eau est install sur un r seau d alimentation en eau la dilatation thermique doit tre r gl e par l installation d un dispositif de r glage de pression Communiquez avec un plombier professionnel pour toute incertitude concernant le choix l installation ou l entretien d un dispositif de dilatation thermique Lorsque qu une pompe de gavage est install e sur un r seau d alimentation en eau vous devez r guli rement entretenir et contr ler le pressostat joint conform ment aux instructions du fabricant Communiquez avec un plombier professionnel pour toute incertitude concernant l entretien de votre syst me de pompe de suralimentation Lorsque qu
7. suivre le mode d emploi avant l installation et l utilisation de ce syst me L installation et l utilisation DOIVENT tre conformes aux codes de plomberie provinciaux et locaux Pour une protection contre le gel retirer la cartouche filtrante lorsque les temp ratures chutent sous 4 4 C 40 F Ne pas installer les syst mes dans des zones o la temp rature ambiante est sup rieure 43 3 C 110 F Ne pas installer sur des canalisations d eau chaude La temp rature de service maximale de l eau de ce syst me de filtrage est 37 8 C 100 F Ne pas installer si la pression d eau est sup rieure 862 kPa 125 psi Il faudra installer un limiteur de pression d eau si la pression d eau est sup rieure 552 kPa 80 psi Communiquer avec un plombier qualifi si vous tes incertain de la m thode de v rification pour votre pression d eau Ne pas installer un endroit sujet aux coups de b lier Un antib lier doit tre install en pr sence de coups de b lier Communiquer avec un plombier qualifi si vous tes incertain de la m thode de v rification de cette condition Ne pas utiliser de chalumeau ou autres sources lev es de chaleur pr s du syst me de filtrage cartouches adaptateurs et plomberie en plastique Ne jamais utiliser de produit d tanch it ou d enduit d enrobage pour tuyau sur les adaptateurs en plastique Utiliser uniquement un ruban de polyt trafluoro thyl ne PTFE pour filet pour
8. suministro de agua principal abra las v lvulas y verifique si hay p rdidas Figura 6 NOTAS IMPORTANTES Si lo desea puede instalar la secci n de desv o alrededor de la unidad enroscando o soldando un accesorio Figura 7 Para reducir el riesgo asociado con los da os materiales debidos a p rdidas de agua o inundaciones e Evite el congelamiento quite el cartucho del filtro cuando las temperaturas puedan ser inferiores a 40 F 4 4 C e Aseg rese de que todos los tubos y accesorios est n fijos y no tengan p rdidas e No instale si la presi n del agua excede las 125 psi 862 kPa Si la presi n del agua excede las 80 psi 552 kPa deber instalar una v lvula de l mite de presi n Contacte a un plomero profesional si no est seguro de c mo verificar la presi n del agua e No instale en lugares donde se pueda producir un golpe de ariete Si existe la posibilidad de un golpe de ariete instale una v lvula de rosca Contacte a un plomero profesional si no sabe c mo verificar esta condici n Figura 7 INSTRUCCIONES PARA CAMBIAR EL CARTUCHO DEL FILTRO Para reducir el riesgo de fuga de agua o inundaci n y para garantizar un rendimiento ptimo del filtro e El cartucho desechable debe reemplazarse cada seis meses o antes gt e Si no reemplaza el cartucho de filtro desechable durante los intervalos recomendados puede disminuir el rendimiento d
9. FICATION INC MAKES NO OTHER WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING CUSTOMER OR USAGE OF TRADE If the Product fails to satisfy this Limited Warranty during the warranty period 3M Purification Inc will replace the Product or refund your Product pur chase price This warranty does not cover labor The remedy stated in this paragraph is Customer s sole remedy and 3M Purification Inc s exclusive obligation This warranty gives you specific legal rights and you may have other rights which may vary from state to state or coun try to country For any warranty questions please call 1 800 222 7880 or mail your request to Warranty Claims 3M Purification Inc 400 Research Parkway Meriden CT 06450 Proof of purchase original sales receipt must accompany the warranty claim along with a complete description of the Product model number and alleged defect Limitation of Liability 3M Purification Inc will not be liable for any loss or damage arising from this 3M Purification Inc product whether direct indirect special incidental or consequential regardless of the legal theory asserted including warranty contract negligence or strict liability Some states and countries do not allow the exclusion or limitation of incidental or consequential damag
10. PLICITE Y COMPRIS MAIS SANS S Y LIMITER TOUTE GARANTIE OU CLAUSE IMPLICITE DE QUALITE MARCHANDE OU D ADAPTATION UN USAGE PARTICULIER OU TOUTE GARANTIE OU CLAUSE IMPLICITE DECOULANT DE LA CONDUITE DES AFFAIRES DES PRATIQUES COURANTES ET DES USAGES DU COMMERCE Si une d fectuosit du Produit survient pendant la p riode couverte par la garantie limi t e 3M Purification Inc remplacera le produit ou remboursera le prix d achat du Produit Cette garantie ne couvre pas la main d oeuvre La voie de recours indiqu e dans ce paragraphe est la seule voie de recours disponible au Client et l obligation exclusive de 3M Il est possible que Putilisateur ait d autres droits cet gard lesquels peuvent varier d une province une autre ou d un pays un autre Pour toutes questions au sujet de la garantie veuillez composer le 1 877 238 9119 ou postez votre demande Warranty Claims 3M Purification Inc 400 Research Parkway Meriden CT 06450 Une preuve d achat facture originale doit accompagner la r clamation au titre de la garantie de m me qu une description compl te du produit le num ro de mod le et le d faut all gu Limite de responsabilit 3M Purification Inc n est pas responsable pour toute perte ou tout dommage direct indirect particulier accessoire ou accidentel suivant l utilisation de ces Produits peu importe l affirmation de th orie juridique y compris la violation de la garantie la responsabilit con
11. age due to water leakage or flooding e Read and follow Use Instructions before installation and use of this system e Installation and use MUST comply with all state and local plumbing codes e Protect from freezing remove filter cartridge when temperatures are expected to drop below 40 F 4 4 C e Do not install systems in areas where ambient temperatures may go above 110 F 43 3 e Do not install on hot water supply lines The maximum operating water temperature of this system is 100 F 37 8 C e Do not install if water pressure exceeds 125 psi 862 kPa If your water pressure exceeds 80 psi 552 kPa you must install a pressure limiting valve Contact a plumbing professional if you are uncertain how to check your water pressure e Do not install where water hammer conditions may occur If water hammer conditions exist you must install a water hammer arrester Contact a plumbing professional if you are uncertain how to check for this condition e Do not use a torch or other high temperature sources near system cartridges plastic fittings or plastic plumbing e On plastic fittings never use pipe sealant or pipe dope Use PTFE thread tape only pipe dope properties may deteriorate plastic e Take care when using pliers or pipe wrenches to tighten plastic fittings as damage may occur if over tightening occurs e Do not install in direct sunlight or outdoors e Mount system in such a position as to prevent it from being struc
12. de d emploi Conserver ce mode d emploi pour consultation future Utilisation du produit Ce syst me inhibiteur d entartrage AP430SS est con u pour le traitement de l eau potable et n a pas t test a d autres fins Le produit est install sur le site d entr e conduite de distribution principale et doit tre install conform ment aux instructions par un professionnel qualifi EXPLICATION DES CONSEQUENCES LIEES Indique une situation potentiellement dangereuse qui si elle n est pas vit e pourrait A MISE EN GARDE entrainer la mort des blessures graves et des d gats mat riels O AVIS Indique une situation potentiellement dangereuse qui si elle n est pas vit e pourrait occasionner des d g ts mat riels A MISE EN GARDE Afin de r duire les dangers d touffement e Ne pas permettre aux enfants de moins de 3 ans d avoir acc s aux petites pi ces durant l installation de ce produit Pour r duire les risques associ s l ingestion de contaminants e Ne pas utiliser avec de l eau qui n est pas s re au point de vue microbiologique ou de qualit incertaine sans assurer une d sinfection ad quate avant ou apr s le syst me Afin de r duire les risques de blessures e Couper l alimentation en eau et d pressuriser le syst me tel qu illustr dans le manuel avant de retirer la cartouche Afin de r duire les risques de d g ts mat riels r sultant d une fuite d eau ou d une inondation Lire et
13. do de Aqua Pure PIEZAS DE REPUESTO Cabeza 6838732 Junta t rica 7205738 Cartucho del filtro AP431 GARANT A LIMITADA La garant a limitada de 3M Purification Inc garantiza que el cabezal de acero inoxidable excepto el o los cartuchos de filtro descartables estar libre de defectos de materiales y fabricaci n durante veinticinco 25 a os a partir de la fecha de compra El cartucho de filtro descartable posee garant a contra defectos de materiales y fabricaci n por el per odo de un 1 a o a partir de la fecha de compra Esta garant a no cubre las fallas debido al abuso uso indebido modificaci n o da o del producto que no hayan sido ocasionadas por 3M Purification Inc o que se hayan producido por el incumplimiento de las instrucciones de uso e instalaci n No se garantiza la vida til de ning n cartucho o membrana de filtro ya que esta var a seg n las condiciones locales del agua y el consumo de agua 3M PURIFICATION INC NO OTORGA NINGUNA OTRA GARANT A NI CONDICI N YA SEA EXPRESA O IMPLICITA INCLUIDA DE MANERA ENUNCIATIVA MAS NO LIMITATIVA CUALQUIER GARANT A O CONDICI N IMPLICITA DE COMERCIALIZACI N O IDONEIDAD PARA UN FIN EN PARTICULAR O CUALQUIER GARANT A O CONDICI N IMPLICITA DERIVADA DE NEGOCIACIONES COSTUMBRES O PR CTICAS DE COMERCIO Si el Producto no cumple con esta garant a limitada durante el per odo de garant a 3M Purification Inc sustituir el Producto o le reembol
14. ecure and free of leaks e Do not install if water pressure exceeds 125 psi 862 kPa If your water pressure exceeds 80 psi 552 kPa you must install a pressure limiting valve Contact a plumbing professional if you are uncertain how to check your water pressure e Do not install where water hammer conditions may occur If water ham mer conditions exist you must install a water hammer arrester Contact a plumbing professional if you are uncertain how to check for this condition NOTICE To reduce the risk of water leakage of flooding and to ensure optimal filter performance e Change disposable filter cartridge every 6 months or sooner if you observe a noticable reduction in water flow rate e Failure to replace the disposable filter cartridge at recommended intervals may lead to reduced filter performance and cracks in the filter housing causing water leakage or flooding Always have spare cartridges on hand 1 Shut off inlet Stop and Waste and outlet Compression Gate valves Open drain on inlet valve to relieve pressure in the AP430SS 2 Unscrew the cartridge AP431 to the left as shown in the illustration Figure 8 3 Install the new cartridge moderately hand tight Never use tools to tighten a cartridge 4 Turn on inlet valve and bleed air through gate valve drain until water appears Then close drain and open outlet valve To Water Heater gt Figure 4
15. el filtro y provocar grietas en la carcasa del filtro lo que generar a fugas de agua o inundaci n Tenga siempre cartuchos de reserva disponibles 1 Cierre las v lvulas de entrada cierre y descarga y salida de compuerta para compresi n Abra la v lvula de vaciado en la v lvula de entrada para aliviar la presi n en el AP430SS 2 Para retirar el cartucho AP431 g relo hacia la izquierda seg n se indica la ilustraci n Figura 8 3 Instale el nuevo cartucho aj stelo con la mano ejerciendo la presi n adecuada No utilice herramientas para ajustar un cartucho LL 4 Abra la v lvula de entrada y purgue el aire a trav s del desag e de la v lvula de compuerta hasta que salga agua Luego cierre el desag e y abra la v lvula de salida Figura 8 NOTAS IMPORTANTES Si est instalando este sistema inhibidor de escala AP430SS en la tuber a de agua fr a que alimenta a un calentador de agua que ya tiene una acumulaci n de escala es posible que haya aflojado la escala que podr a ir hacia abajo y atascar la v lvula y los aireadores En este caso se debe instalar un filtro y un dep sito para agua caliente de acero inoxidable del lado del agua caliente del calentador para retener y contener esta escala Sistema calentador de agua o sin tanque de escala modelo nro AP430SS Aqua Pure Modelo nro SST1HA con filtro opcional de acero inoxidable para agua con dep sito y xi
16. ensure optimal filter performance e Change the disposable filter cartridge every 6 months or sooner if you observe a noticeable reduction in water flow rate e Failure to replace the disposable filter cartridge at recommended intervals may lead to reduced filter performance and cracks in the filter housing causing water leakage or flooding e For questions or concerns please contact Customer Service at 1 800 222 7880 IMPORTANT NOTES e Failure to follow instructions will void warranty e Allow a minimum of 2 5 1 cm clear space under filter to facilitate cartridge change e Install with the inlet and outlet ports as labeled Make sure not to reverse connections GETTING STARTED Tools and Parts Required not included 1 One 3 4 Stop Waste Valve Compression Type 2 PTFE Tape 3 Two 3 4 Male x 3 4 Street Adapters 4 One 3 4 Compression Gate Valve 5 Pipe Cutter Identify all parts as shown in diagram Read all instructions carefully before attempting to start installation The existing shut off valve remains in place and still acts as the cold water shut off This filter system has 3 4 connections The AP430SS can be adapted to various pipe sizes by using reducing adapter on either end Installation fittings can be sweated or threaded Use galvanized fittings for installation on galvanized pipe IMPORTANT NOTES e Allow a minimum of 2 5 1 cm clear space under filter to facilitate cartr
17. ent en eau 1 Enrouler du ruban de PTFE autour des raccordements filet s des adaptateurs et visser aux deux extr mit s de la t te de la cartouche Ne pas utiliser de garniture d tanch it ni d enduit d enrobage car ils contiennent des solvants qui peuvent endommager les raccordements figure 1 Placer la fleche indiquant le sens du d bit dans le bon sens sur la t te du filtre La fl che de la t te du filtre doit pointer en direction du chauffe eau 2 Installer les raccordements compression sur la t te de la cartouche l aide des adaptateurs sans resserrer En maintenant en place la t te de la cartouche munie des adaptateurs vis vis du tuyau indiquer la longueur de tuyau retirer Couper la canalisation l aide du coupe tuyau figure 2 Figure 1 3 l aide du raccord compression de la valve fixer le robinet d charge au tuyau du chauffe eau avant le syst me du c t de l eau froide en pointant AL LU LL LL LL LL la fl che d indication vers l assemblage AP430SS de fa on ce que l crou FT A tools lo loro aio lil uli de vidange soit accessible pour relacher la pression au moment de changer la cartouche Pour r duire les risques associ s aux dommages la propri t occasionn s par les fuites d eau ou inondation Ne pas installer sur la canalisation d alimentation en eau chaude La temp rature maximum de fonction
18. es so the above limitation or exclusion may not apply to you INFORMACION DE SEGURIDAD Lea entienda y siga toda la informaci n de seguridad incluida en estas instrucciones antes de instalar y utilizar este sistema inhibidor de escala AP430SS Guarde estas instrucciones para futuras consultas Uso previsto El sistema inhibidor de escala AP430SS est dise ado para utilizarse para el tratamiento de agua potable y no se ha evaluado para otros usos El producto se instala en el punto de entrada tuber a de distribuci n principal y debe ser instalado por un profesional debidamente calificado seg n lo especificado en las instrucciones de instalaci n EXPLICACI N DE LAS CONSECUENCIAS DE PALABRAS SIMBOLOS DE ADVERTENCIA Indica una situaci n potencialmente peligrosa que si no se evita puede provocar la A ADVERTENCIA muerte lesiones graves o da os a la propiedad Indica una situaci n potencialmente peligrosa que si no se evita puede provocar da os a la propiedad A ADVERTENCIA Para reducir el riesgo asociado con asfixia e No deje las piezas peque as al alcance de ni os menores de 3 a os mientras instala el producto Para reducir el riesgo asociado con la ingesti n de contaminantes e No utilice el producto con agua microbiol gicamente insegura o de calidad desconocida sin desinfectar adecuadamente el sistema antes o despu s Para reducir el riesgo de lesiones f sicas e Cierre el suministro de agua de entrada y despr
19. es y enrosque ambos extremos de la cabeza del cartucho No utilice ning n sellador de roscas ni grasa para roscas ya que pueden contener solventes que pueden deteriorar los accesorios Figura 1 Posicione la flecha de direcci n de flujo en la cabeza del filtro para lograr una orientaci n adecuada La flecha en la cabeza del filtro debe apuntar hacia el calentador de agua 2 Calce los accesorios de compresi n con los adaptadores en la cabeza del cartucho sin ajustarlos demasiado Marque el largo del tubo que debe retirar acercando a la tuber a la cabeza del cartucho con los adaptadores conectados Utilice un cortador de tubos para reducir el largo de la tuber a Figura 2 Ec ATT 3 Mediante el conector a compresi n de la v lvula instale la v lvula de cierre y descarga en la tuber a antes del sistema en la tuber a de agua fr a que va hacia podido blabla el calentador de agua La flecha indicadora debe estar orientada hacia el con junto del sistema AP430SS de modo que permita un f cil acceso a la tuerca de vaciado para aliviar la presi n cuando se realice un cambio del cartucho 2 Figura 1 Para reducir el riesgo asociado con los da os materiales debidos a p rdidas m aa de agua o inundaciones SS AS No lo instale en tuber as de suministro de agua caliente Para que el Y producto funcione la temperatura m xima del agua del sistema de filtrado debe ser 100 F 37 8 C
20. ese con un plomero profesional si tiene dudas acerca de c mo mantener su sistema de bomba de carga e Donde est instalada la bomba de carga en el sistema de agua debe instalar una v lvula de alivio de presi n adecuada La v lvula de alivio de presi n debe mantenerse e inspeccionarse cada 6 meses Comun quese con un plomero profesional si tiene dudas acerca de c mo seleccionar instalar mantener una v lvula de alivio de presi n e Donde est instalada la bomba de carga en el sistema de agua debe instalar una v lvula reguladora de presi n adecuada y regular la presi n de agua a lt 80 psi Comun quese con un plomero profesional si tiene dudas acerca de c mo seleccionar instalar mantener una v lvula reguladora de presi n Para reducir el riesgo de fuga de agua o inundaci n y para garantizar un rendimiento ptimo del filtro e Cambie el cartucho de filtro desechable cada seis 6 meses o menos si observa una reducci n considerable del caudal de agua e Si no reemplaza el cartucho de filtro desechable durante los intervalos recomendados puede disminuir el rendimiento del filtro y provocar grietas en la carcasa del filtro lo que generar a fugas de agua o inundaci n e Si tiene preguntas o inquietudes comun quese con Atenci n al cliente llamando al 1 800 222 7880 NOTAS IMPORTANTES e El incumplimiento de las instrucciones puede anular la garant a e Deje un espacio m nimo de 2 5 1 cm debajo del filtro para facilitar e
21. esurice el sistema seg n se indica en el manual antes de quitar el cartucho Para reducir el riesgo asociado con los da os materiales debidos a p rdidas de agua o inundaciones e Lea y siga las Instrucciones de uso antes de la instalaci n y uso de este sistema e La instalaci n y uso DEBE cumplir con todos los c digos de plomer a locales y estatales e Protecci n contra congelamiento quite el cartucho del filtro cuando se espera que las temperaturas est n por debajo de los 40 F 4 4 C No instale sistemas en reas donde la temperatura ambiental puede estar por encima de los 110 F 43 3 C No instale sobre tuber as de suministro de agua La m xima temperatura del agua para el correcto funcionamiento de este sistema de filtro es 100 F 37 8 C No instale si la presi n de agua excede los 125 psi 862 kPa Si su presi n de agua excede los 80 psi 552 kPa puede instalar una v lvula de presi n P ngase en contacto con un plomero profesional si no est seguro sobre c mo medir su presi n de agua No instale en lugares en donde pueda ocurrir un martilleo de agua Si existe martilleo de agua debe instalar un protector contra martilleo de agua P ngase en contacto con un plomero profesional si no est seguro sobre c mo verificar si existe este problema En lugares en los que hay una v lvula de contraflujo instalada en el sistema de agua se debe instalar una v lvula para control de presi n debido a la dilataci n t rmica N
22. idge change Before starting shut off main water supply and drain pipes Shut off fuel or electric power supply to water heater after water is shut off i 1 Using PTFE tape wrap the threaded ends of the adapters and screw into both ends of the cartridge head Do not use pipe sealant dope as they may contain solvents that may deteriorate fittings Figure 1 B Position the flow direction arrow on the filter head for proper orientation The arrow on the filter head should be pointing toward the water heater E 2 Loosely fit compression fittings onto the cartridge head with adapters Holding the cartridge head with attached adapters up to the pipe mark for length of pipe to be removed Using a pipe cutter cut pipe Figure 2 SS 3 Using the valve compression fitting attach the stop and waste valve on pipe Figure 1 before the system on the cold water side to the water heater with indica tor arrow pointing towards the AP430SS assembly so that drain nut can be TTT accessed to release pressure when changing cartridge Be sure the drain nut is A A firmly tightened Figure 3 NOTICE To reduce the risk associated with property damage due to water leakage or flooding Do not install on hot water supply lines The maximum operating water temperature of this filter system is 100 F 37 8 C Installation and Use MUST comply with all state and local plumbing codes On plastic fittings
23. k by other items used in the area of installation e Ensure that the location and fasteners will support the weight of the system when installed and full of water e Ensure all tubing and fittings are secure and free of leaks e SHUT OFF FUEL OR ELECTRIC POWER SUPPLY TO WATER HEATER after water is shut off NOTICE e Where a backflow prevention device is installed on a water system a device for controlling pressure due to thermal expansion must be installed Contact a plumbing professional if you are uncertain how to select install maintain a thermal expansion device e Where a booster pump is installed on a water system you must maintain and inspect the attached pressure switch regularly in accordance with the booster pump manufacturer s instructions Contact a plumbing professional if you are uncertain how to maintain your booster pump system e Where a booster pump is installed on a water system you must install an appropriate pressure relief valve Pressure relief valve must be maintained and inspected every 6 months Contact a plumbing professional if you are uncertain how select install maintain a pressure relief valve e Where a booster pump is installed on a water system you must install an appropriate pressure regulating valve and regulate water pressure to lt 80psi Contact a plumbing professional if you are uncertain how select install maintain a pressure regulating valve To reduce the risk of water leakage of flooding and to
24. l cambio de cartucho e Instale con los puertos de entrada y de salida tal como se indica en las etiquetas Aseg rese de no invertir las conexiones INTRODUCCI N Herramientas y piezas requeridas no incluidas 1 Una v lvula de cierre y descarga tipo de compresi n de 3 4 1 9 cm 2 Cinta de PTFE 3 Dos adaptadores con rosca de 3 4 1 9 cm macho x 3 4 1 9 cm 4 Una v lvula de compuerta de compresi n de 3 4 1 9 cm 5 Cortatubos Identifique todas las piezas como se indica en el diagrama Lea cuidadosamente todas las instrucciones antes de comenzar la instalaci n La v lvula de cierre existente se mantiene en su lugar y funciona a medida que el paso de agua fr a se cierra Este filtro tiene conexiones de 3 4 1 9 cm El sistema AP430SS puede adaptarse a varias medidas de tubos colocando un adapta dor reductor en cualquier extremo Los accesorios de instalaci n se pueden soldar o enroscar Utilice accesorios galvanizados para las instalaciones de tubos galvanizados NOTAS IMPORTANTES e Deje un espacio m nimo de 2 5 1 cm debajo del filtro para facilitar el cambio de cartucho IMPORTANTES INSTRUCCIONES DE INSTALACI N Antes de comenzar cierre el suministro de agua principal y las tuber as de desag e Corte el suministro el ctrico o a combusti n del calentador de agua despu s de interrumpir el suministro de agua 1 Utilice la cinta de PTFE para envolver los extremos roscados de los adaptador
25. nement permise pour ce syst me de filtration est de 37 8 C 100 F L installation et l utilisation DOIVENT tre conformes tous les codes gouvernemen taux et de plomberie Ne pas utiliser de garniture d tanch it ou d enduit d enrobage avec les raccordements de plastique Utiliser uniquement du ruban d tanch it PTFE car les composants de l enduit d enrobage sont susceptibles de d t riorer le plastique Ne pas utiliser de torche ou d autres appareils d gageant beaucoup de chaleur pr s du syst me de filtration des cartouches des raccordements ou de la tuyauterie en plastique S assurer que l emplacement et les attaches sont ad quats pour supporter le poids du syst me S assurer que tous les tuyaux et raccords sont solides et exempts de fuites Direction duhir COUPER L ALIMENTATION EN LECTRICIT OU EN CARBURANT DU CHAUFFE EAU aia APRES AVOIR COUPER L APPROVISIONNEMENT EN EAU Figure 3 DIRECTIVES D INSTALLATION IMPORTANTES suite 4 Fixer le robinet vanne l arriv e de la canalisation d alimentation l aide du raccordement compression Bien resserrer l crou de serrage figure 4 REMARQUES IMPORTANTES al Il peut tre n cessaire d carter l g rement les extr mit s des canalisations afin de pouvoir ins rer le module de t te de AP430SS dans la soupape Direction du chauffe eau E A 2 5 Bien resserrer tous les crous de serrage en maintena
26. never use pipe sealant or pipe dope Use PTFE thread tape only pipe dope properties may deteriorate plastic Do not use a torch or other high temperature sources near filter system cartridges plastic fittings or plastic plumbing Ensure that the location and fasteners will support the weight of the system Ensure all tubing and fittings are secure and free of leaks To Water Heater SHUT OFF FUEL OR ELECTRIC POWER SUPPLY TO WATER HEATER after AS water is shut off Figure 3 IMPORTANT INSTALLATION INSTRUCTIONS Continued 4 Using the valve compression fitting attach the gate valve to the incoming water supply pipe after the system Firmly tighten compression nut Figure 4 IMPORTANT NOTES lt may be necessary to slightly spread pipe ends apart in order to insert the AP430SS head assembly with adapters into valve 5 Tighten all compression nuts firmly keeping the AP430SS head assembly verti cal Figure 5 6 Screw cartridge to the right into the AP430SS filter head Turn on main water supply open valves and check for leaks Figure 6 IMPORTANT NOTES Optional By Pass Section can be installed around unit if desired using either threaded or sweated fitting Figure 7 NOTICE To reduce the risk associated with property damage due to water leakage or flooding e Protect from freezing remove cartridge when temperatures are expected to drop below 40 F 4 4 C e Ensure all tubing and fittings are s
27. nt le module de t te de Figure 4 l AP430SS la verticale figure 5 6 Visser la cartouche vers la droite dans la t te du filtre de l AP430SS Ouvrir la canalisation d alimentation principale ouvrir les robinets et v rifier tous les joints pour rep rer les fuites figure 6 REMARQUES IMPORTANTES Une section de contournement peut tre install e autour du module si d sir l aide de raccords filet s ou soud s figure 7 Pour r duire les risques associ s aux dommages la propri t occasionn s par les fuites d eau ou inondation e Prot ger du gel et retirer la cartouche si la temp rature ambiante doit descendre sous les 4 4 C 40 F e S assurer que tous les tuyaux et raccords sont solides et exempts de fuites e Ne pas installer sur une conduite d eau dont la pression est sup rieure 862 kPa 125 psi Si la pression est sup rieure 552 kPa 80 psi il est n cessaire d installer une soupape de limitation de pression En cas de doute sur la mani re de v rifier la pression de l eau communiquer avec un plombier e Ne pas installer l o des coups de b lier peuvent se produire S il se produit des coups de b lier il est n cessaire d installer un dispositif antib lier En cas de doute sur la mani re de v rifier cette situation communiquer avec un plombier Figure 7 DIRECTIVES DE REMPLACEMENT DE LA CARTOUCHE FILTRANTE masses ll I
28. o use soplete ni otra fuente de alta temperatura cerca del sistema de filtros cartuchos o acoples y tuber as de pl stico En los acoples pl sticos nunca utilice sellador o pegamento para tuber as S lo utilice cinta de PTFE las propiedades del pegamento pueden destruir el pl stico e Tenga cuidado al usar pinzas o llaves inglesas para ajustar los acoples de pl stico puede da arse si se aprieta demasiado e No instale donde le d el sol directamente o en exteriores e Instale sistema en una posici n tal que se evite ser golpeado por otros objetos usados en el rea de instalaci n e Aseg rese de que el lugar y las fijaciones aguantar n el peso del sistema cuando est instalado y lleno de agua e Vea de que todas las tuber as y acoples est n seguros y sin fugas e CIERRE EL SUMINISTRO DE COMBUSTIBLE O DE ENERG A ELECTRICA PARA EL CALENTADOR DE AGUA despu s de cerrar el suministro de agua e Si un sistema de agua tiene instalado un dispositivo para evitar el contraflujo se debe instalar un dispositivo para controlar la presi n ocasionada por la dilataci n t rmica Comun quese con un plomero profesional si tiene dudas acerca de c mo seleccionar instalar mantener un dispositivo de expansi n t rmica e En el lugar donde est instalada la bomba de carga del sistema de agua debe mantener e inspeccionar el interruptor de presi n conectado con frecuencia seg n las instrucciones del fabricante de la bomba de carga Comun qu
29. s le filtre pour faciliter le changement de la cartouche e Installer avec les orifices d entr e et de sortie aux endroits indiqu s sur l tiquette S assurer de ne pas intervertir les raccordements D MARRAGE Outils et pieces n cessaires non compris 1 Un robinet d arr t limiteur de suralimentation de 3 4 po type compression 2 Ruban de PTFE 3 Deux adaptateurs de raccord mixte 3 4 m le po x 3 4 po 4 Un robinet vanne d arr t compression de 3 4 po 5 Coupe tuyau Identifier toutes les pi ces repr sent es dans le sch ma Lire avec soin toutes les directives avant de commencer l installation Le robinet d arr t d j en place demeure et sert toujours couper l eau froide Ce filtre comporte des raccordements de 3 4 po Le filtre AP430SS peut s adapter pour convenir diff rentes tailles de tuyaux l aide d un adaptateur de r duction l entr e et la sortie Les raccordements d installation peuvent tre soud s ou filet s Utiliser des raccordements galvanis s pour installer sur des tuyaux galvanis s REMARQUES IMPORTANTES e Laisser un espace libre d au moins 5 1 cm 2 po sous le filtre pour faciliter le changement de la cartouche DIRECTIVES D INSTALLATION IMPORTANTES Avant de commencer l installation couper l alimentation principale et vidanger les tuyaux Couper l alimentation en lec tricit ou en carburant du chauffe eau apr s avoir couper l approvisionnem
30. sar el precio de compra del Producto Esta garant a no cubre mano de obra El recurso mencionado en este p rrafo ser el nico recurso del Cliente y la nica obligaci n de 3M Esta garant a le otorga derechos legales espec ficos y es posible que usted tenga derechos adicionales que pueden variar seg n el estado o el pa s Para realizar consultas relacionadas con la garant a llame al 1 877 238 9119 o env e su petici n por correo a Warranty Claims 3M Purification Inc 400 Research Parkway Meriden CT 06450 La reclamaci n de garant a debe ir acompa ada del comprobante de compra el recibo de venta original y de una descripci n detallada del Producto el n mero de modelo y el presunto defecto Limitaci n de responsabilidad 3M Purification Inc no ser responsable de las p rdidas o da os derivados del uso de este pro ducto de 3M Purification Inc ya sea en forma directa indirecta especial incidental o resultante independientemente de la teor a legal que se aplique incluida la garant a contrato negligencia o responsabilidad estricta Algunos estados o pa ses no permiten la exclusi n de limitaci n de los da os incidentales o resultantes de manera que la limitaci n o exclusi n anterior puede no aplicarse en SU Caso CONSIGNES DE S CURIT Avant d installer et d utiliser ce syst me inhibiteur d entartrage AP430SS s assurer de lire comprendre et suivre toutes les consignes de s curit que renferme ce mo
31. st n cessaire d installer un filtre s diments et rouille en acier inoxydable la sortie d eau chaude pour recueillir et retenir ce tartre Chauffe eau ou syst me sans r servoir d entartrage Aqua Pure mod le n AP430SS Mod le n Aqua Pure SST1HA avec filtre 4 s diments et rouille en acier inoxydable AP2005 facultatif PIECES DE RECHANGE T te 6838732 Joint torique 7205738 Cartouche filtrante AP431 GARANTIE LIMIT E La garantie limit e de 3M Purification Inc garantit que la t te en acier inoxydable excluant les cartouches filtrantes jetables sera exempte de d fectuosit s dans son mat riel et sa fabrication pour une p riode de vingt cinq 25 ans compter de la date d achat La cartouche filtrante jetable est prot g e par la garantie de toutes d fectuosit s dans son mat riel et sa fabrication pour une p riode d un 1 an compter de la date d achat Cette garantie ne couvre pas les d fectuosit s occasionn es par une utilisation abusive ou le m susage l alt ration ou le dommage non occasionn par 3M Purification Inc ou le d faut de respecter les instructions d installation et d utilisation Aucune garantie n est fournie pour la dur e de vie utile de toute cartouche filtrante ou membrane cause des conditions d eau locales ou des quantit s d eau consomm es 3M PURIFICATION INC N OFFRE AUCUNE AUTRE GARANTIE OU CLAUSE EXPLICITE OU IM
32. tractuelle la n gligence ou la responsabilit stricte Certaines provinces et certains pays ne permettent pas l exclusion ou la limitation de responsabilit pour les dommages fortuits ou cons quents Dans un tel cas la clause d exclusion ou de limitation ci dessus ne s applique pas 3M Purification Inc 400 Research Parkway Meriden CT 06450 USA Toll Free 1 800 222 7880 Worldwide 203 237 5541 Fax 203 238 8701 www 3Mpurification com www aquapure com O 2014 3M Company All rights reserved 3M and Aqua Pure are trademarks of 3M Company 34 8715 6240 0