1. Instruction Manual 10156 API Compatible 5 wire Optic Sensor PRODUCT DESCRIPTIONS These instructions cover the following FloTech product FT 100 API Compatible 5 wire Replacement Optic Probe FT 100 12 API Compatible 5 wire Replacement Optic Probe 12 FT 100 18 API Compatible 5 wire Replacement Optic Probe 18 FT101 API Compatible Swire Sensor with 2 NPT Probe Holder FT101 12 API Compatible Swire Sensor with 2 NPT Probe Holder 12 FT101 18 API Compatible Swire Sensor with 2 NPT Probe Holder 18 INSTALLATION INSTRUCTIONS FloTech model FT101 can be mounted in 2 NPT female pipe coupling or through a 2 3 8 hole When mounting in a 2 3 8 hole the gasket and lock nut provided are used to retain the probe holder in the tank shell or manhole After the sensor is mounted remove the cap Loosen the probe clamp screw and adjust the probe to the correct level point This is typically 60 gallons or 250 liters above the sensor prism It is not recommended cutting the standard 7 sensor to a shorter length This will cause insufficient time to stop the flow of product within the load racks reaction time Longer 12 or 18 sensors may be cut to length with a tubing cutter IMPORTANT The actual sensing point adjustment should be determined by the total response time required to prevent a tank overfill condition The FloTech sensor reaction time is one half second
2. Capteur optique 5 brins API compatible DESCRIPTION DES PRODUITS Ces instructions sont pour les produits FloTech suivants FT 100 Sonde optique de remplacement 5 brins API Compatible FT 100 12 Sonde optique de remplacement de 12 a 5 brins API Compatible FT100 18 Sonde optique de remplacement de 18 a 5 brins API Compatible 01 Boitier pour sonde de 7 NPT 2 capteur API compatible 5 brins FT 101 12 Boitier pour sonde de 12 NPT de 2 avec capteur 5 brins API compatible FT101 18 Boitier pour sonde de 18 NPT de 2 avec capteur a 5 brins API compatible Pour vente et service contactez E U Dixon Bayco USA Chestertown Maryland T l phone 410 778 2000 Fax 410 778 4702 Sans frais 800 355 1991 E mail dixonbayco dixonvalve com www dixonbayco com Mexique Dixva S de R L de C V Monterrey N L T l phone 01 800 00 DIXON 34966 Fax 01 81 8354 8197 E mail contactenos dixonvalve com mx www dixonvalve com Asie et Pacifique Dixon Asia Pacific Pty Ltd Wingfield South Australia T l phone 61 8 8202 6000 Fax 61 8 8202 6099 E mail enquiries dixonvalve com au www dixonvalve com au Canada Dixon Group Canada Limited Innisfil Barrie Ontario T l phone 705 436 1125 Fax 705 436 6251 Sans frais 877 963 4966 E mail isales dixongroupcanada com www dixongroupcanada com Europe Dixon Group Europe Ltd Pr
3. The loading rack will also have a reaction time Once the probe is adjusted to the proper height tighten the clamp screw 1 2NPT 2 HOLES Dixon Bayco 4740T Interstate Dr Cincinnati OH 45246 Rev F Aug 2010 513 874 8499 FX 513 874 8399 Page 1 WIRING INSTRUCTIONS It is highly recommended to use FloTech FT400 jacketed 5 conductor cable when wiring a new system FloTech cable is designed to be oil UV and abrasion resistant We incorporate a noble tin plated stranded copper wire which resist corrosion These features will provide years of reliable service Do not use after market cable if bare copper wire reddish tint is visible when the wire insulation is stripped After all sensors are mounted in each compartment align the conduit openings so they face the roll over rail Thread in cable glands and pull a length of cable through the conduit openings between each sensor Cut to length leaving approximately 8 inches extra length exiting the top of each probe holder All sensor wires must enter or leave the probe holder through one of the 1 2NPT openings Use FloTech FT402 1 cable glands to ensure a water tight seal Unused conduit openings must a gt NPT pipe plug installed Use pipe dope on all 2 NPT threads to ensure a water tight seal Wire the sensor according to diagram F1 below Double check your wiring connection when complete NOTE It is highly recommended to use a small amount of Silicone RTV se
4. 7 UNDER 5 16 BOLT nl ADDITIONAL SENSOR SENSOR SENSOR ound Bolt SENSORS 2 82 1 BLACK GROUND TRACTOR RED POWER YELLOW SIGNAL TO D WIRING NSOR GREEN DIAGNOSTIC SE ORANGE RETURN SIGNAL JS60 TYPE SOCKET FT306 Z MOUNT THIS EYELET J UNDER 5 16 BOLT WHT Tank Ground SENSOR SENSOR SENSO ORANGE lt SIGNAL RETURN ORC ORG ORG RED POWER RED RED RED BLACK GROUND BLK BLK BLK GREEN DIAGNOSTIC GRN GRN GRN YELLOW SENSOR 1 YEL YEL TER FLOTECH OPTIC Sle SE SOCKETS FT300 amp FT303 EE N SENSOR HOUSING VOUNT THIS EYELET UNDER 6 BOLT MOUNT TO TRAILER GROUND SENSOR SENSOR SENSOR SENSOR 1 3 4 KS SENSOR BLACK lt GROUND gt z NEAREST TRACTOR RED POWER WIR YELLOW SIGNAL TO 1 GREEN DIAGNOSTIC TO SENSOR ORANGE RETURN SIGNAL aul OPTIC J560 1 SOCKET FT306 a ets nc So Wl R 5 16 BOLT WHT Tank Ground Dixon Bayco 4740T Interstate Dr Cincinnati OH 45246 Rev F Aug 2010 PH 513 874 8499 FX 513 874 8399 Page 3 Entretien amp Mode d emploi
5. QUE PRISE FT300 amp FT303 INDIQUE LA CONNEXION DANS LE BOITIER POUR INSTALLEZ OUILLET SONDE SOUS UN BOULON 516 BOULON OPTICAL 50 FLOTECH DE MISE ATERRE CAPTEUR NOIR MISE TERRE RED COURANT 5 VERT DIAGNOSTIQUE ORANGE SIGNAL DE RETOUR INSTALLEZ CET OUILLET SOUS UN BOULON 516 CAPTEUR LE PLUS PR LAC ITERNE GEO TYPE OPTIQUE J560 PRISE FT306 FIL BLANC MISE TERRE DE LA CITERNE SYST ME CANADIEN 4 COMPARTIMENTS BOITIER POUR BOITIER POUR BOITIER POUR BOITIER POUR SONDE SONDE SONDE SONDE Le _ ORANGE SIGNAL DE RETOUR 7 VERT 8 ROUGE COURANT 9 00 NOIR MISE TERRE VERT DIAGNOSTIQUE 6 a JAUNE SIGNAL AU 1 FLOTECH OPTIQUE PRISE FT300 amp FT303 INDIQUE LA CONNEXION 45 9 LE BOITIER POUR IPASE INSTALLEZ CET OUILLET SONDE SOUS UN BOULON DE 5 18 Y BOULON OPTICAL FT450 FLOTECH x DE MISE TERRE 4 NOIR MISE TERRE ROUGE COURANT JAUNE SIGNAL AU 1 VERT DIAGNOSTIQUE ORANGE SIGNAL DE RETOUR M Fl INSTALLEZ GET OUILLET SOUS UN BOULON DE 5 16 CAPTEUR LE PLUS PRES O ELA CITERNE FIL BLANC DE MISE TERRE DE LA CITERNE ADO TONNE 4 10156 Rev F fr
6. alant in each crimp connection Fill the FloTech butt end crimps with Silicone RTV sealant prior to inserting the wires then crimp This will provide a watertight and vibration resistant connection that will last for years Do not use twist on connections wire nuts When wiring is complete replace each sensor cap and o ring CAUTION Do not pinch a sensor wire when installing the cap Note Trailer wiring for the US is different that trailer wiring in Canada Both schematics are provided NEED TECHNICAL ASSITANCE CALL 877 582 3569 In The United States In Canada Dixon Bayco USA Dixon Bayco LTD 800 High St 2315 Bowman ST Chestertown MD 21620 Innisfil Ontario LOS 3V6 Office 800 355 1991 Canada Fax 800 283 4966 Office 705 436 1125 Fax 705 436 6251 Toll Free 800 355 1991 Dixon Bayco 4740T Interstate Dr Cincinnati OH 45246 Rev F Aug 2010 PH 513 874 8499 FX 513 874 8399 Page 2 US 4 COMPARTMENT SYSTEM SENSOR SENSOR SENSOR SEN HOUSING HOUSING HOUSING HOUS INC YELLOW SIGNAL TO 1 YEL YEL YEL RED POWER RED RED RED GREEN DIAGNOSTIC GRN GRN GRN ORANGE RETURN SIC ORC ORC ORG BLACK GROUND BLK BLK BLK d fe 2 2 2 FLOTECH OPTIC 9 9 9 SOCKETS FT300 amp FT3 ECTIONS 8 THE SENSOR HOUSING o gt MOUNT THIS EYELET Ne
7. er de la sonde par une des ouvertures de 2 Utilisez le FT402 FloTech de presse toupe pour assurer une bonne tanch it Pour les ouvertures de c ble qui ne sont pas utilis installez un bouchon de tuyau de gt NPT Utilisez une p te joint pour les filets de NPT pour une bonne tanch it Connectez le capteur comme illustr sur le diagramme F1 illustr V rifiez votre connexion une fois install NOTE Nous vous recommandons d utiliser un peu de Silicone lors du sertissage de chaque connexion avant d ins rer les brins l int rieur Cela produira une bonne tanch it et une bonne r sistance contre les vibrations pour plusieurs ann es N utilisez pas un serre fils sur la connexion Une fois que le c blage sera complet remplacez les couvercles et les joints toriques de chaque capteur ATTENTION Ne pincez pas le fil du capteur lorsque vous installez le couvercle Note Le c blage de remorque pour les tats Unis est diff rent du c blage de remorque pour le Canada Les deux sch mas sont fournis BESOIN D ASSISTANCE TECHNIQUE APPELEZ LE 877 582 3569 10156 Rev F fr FIGURE 1 0 SYSTEME AMERICAIN 4 COMPARTIMENTS BOITIER POUR BOITIER POUR BOITIER POUR BOITIER POUR SONDE SONDE SONDE SONDE Pen ane ane 7 JAUNE SIGNALAU 1 ROUGE COURANT NOIR MISE A TERRE VERT DIAGNOSTIQUE ORANGE SIGNAL DE RETOUR VERT LR FLOTECH OPTI
8. eston England T l phone 44 0 1772 323529 Fax 44 0 1772 314664 E mail enquiries dixoneurope co uk www dixoneurope co uk The Right Connection 10156 Rev F fr INSTRUCTIONS D INSTALLATION Le mod le FT101 FloTech peut tre viss sur un tuyau femelle de 2 NPT ou install dans un trou de 2 3 8 Lorsque vous l installez dans le trou de 2 3 8 le joint d tanch it et l crou de blocage sont fournis pour retenir le support de la sonde dans la citerne ou dans le trou d homme Apr s avoir install le capteur retirez le couvercle Desserrez la vis de serrage de la sonde et ajustez la sonde au niveau appropri Nous ne recommandons pas de couper la sonde de 7 plus courte Cela pourrait nuire aux rampes de chargements d arr ter le d bit du produit dans la dur e de temps allou Les sondes de 12 et de 18 peuvent tre coup e plus courtes Instructions pour couper les sondes 1 Retirez le protecteur noir pour filets 2 Mesurez la nouvelle longueur de la sonde La sonde devrait tre r gl e pour un minimum de 60 gallons ou 250 litres d espace dans la citerne apr s que la sonde soit mouill e 3 Tenez la sonde dans une main lorsque vous la couper en utilisant un coupe tube Ne mettez pas le capteur dans un tau Cela endommagera le capteur 4 Coupez le tube en utilisant un coupe tube N utilisez pas une scie Ne coupez pas le tube plus court que 7 5 Remettez le protecteur p
9. our filets IMPORTANT Le r glage du point r el de d tection doit tre d termin par le temps de r ponse total n cessaire pour viter qu une situation de d bordement de la citerne Le temps de r action du capteur FloTech est d une seconde et demie La station de chargement aura aussi un temps de r action Une fois que la sonde sera ajust e la bonne longueur serrez la vis de serrage 1 2NPT 2 TROUS 10156 Rev F fr INSTRUCTIONS DE C BLAGE Nous vous recommandons d utiliser le c ble FT400 FloTech 5 brins conducteurs lorsque vous installez un nouveau system Le cable FloTech est con u pour tre r sistant l huile UV et l abrasion Nous int grons un fil de cuivre tam r sistants la corrosion Ces traits vous procureront des ann es fiables de service N utilisez pas des c bles provenance du march des pi ces de rechange si les fils de cuivre teint rouge l g re est sont visible lorsque l isolant du fil est d pouill Apr s que chaque capteur soit install dans chaque compartiment alignez les ouvertures des c bles de fa on qu ils soient en face du de renversement Vissez le presse toupe et tirez la longueur du c ble dans l ouverture entre chaque capteur Coupez la longueur appropri e en laissant approximativement 8 de c ble additionnel sur la partie sup rieur du boitier de la sonde Tous les brins du capteur doivent entrer ou sortir du boiti