Home

remote control

image

Contents

1. S C QT Dre N 92 19 10 1992 commande distance Manuel d utilisation pour climatiseur de toiture CIATUNIT g r par MICROPROCESSEUR MICROCIAT MRS 2 remote control Operating instructions for CIATUNIT roof top air conditioner controlled by MRS 2 MICROCIAT MICROPROCESSOR Cher Client Vous venez acqu rir un climatiseur CIAT g r par microprocesseur dans le but d am liorer votre confort Nous vous remercions de votre confiance et sommes persuad s que cet appareil vous donnera enti re satisfaction Ce climatiseur d une conception moderne poss de de nombreuses possibilit s Aussi afin de pouvoir jouir de tous ces avantages nous vous conseillons de lire attentivement le mode d emploi avant de mettre votre climatiseur en marche Dear customer You just acquired a microprocessor controlled CIAT air conditioning unit which will im prove your conditions of comfort We thank you for your confidence and are convinced that this unit will give you entire satis faction This air conditioning unit with a modern design has a lot of possibilities Therefore in order to be able to enjoy all of these advantage we advise you to carefully read the operating instructions before starting your unit Description 1 Touche marche arr t avec signalisation 2 Touche fonction rafra chissement avec signalisation 3 Touche fonction chauffage avec signalisation 4 Touche test lampe
2. moin lumineux vert Go s teignent Mode de fonctionnement e Ventilation seule Appuyer sur la touche seul le ventilateur de soufflage fonctionne Les t moins lumineux jaune et vert El o s allument e Chauffage seul Le ventilateur de soufflage doit fonctionner Appuyer sur la touche son t moin lumineux jaune s al lume Le t moin lumineux de la touche doit tre teint Dans ce cas le climatiseur produira uniquement du chaud si n cessaire Pour annuler exercer une 2 pression sur la touche hk o alors seul le ventilateur de soufflage fonctionne e Rafra chissement seul Le ventilateur de soufflage doit fonctionner Appuyer sur la touche son t moin lumineux jaune s al lume Le t moin lumineux de la touche doit tre teint Dans ce cas le climatiseur produira uniquement du froid si n cessaire Pour annuler exercer une 2 pression sur la touche o alors seul le ventilateur de soufflage fonctionne e Chauffage et rafra chissement automatique Le ventilateur de soufflage doit fonctionner Appuyer sur les touches et ko leur t moin lumi neux jaune s allume Dans ce cas le climatiseur produira ou du chaud ou du froid automatiquement selon les besoins Pour annuler exercer une 2 pression sur les touches et o alors seul le ventilateur de soufflage fonctionne Operating instruction The display panel gives in permanence the ambient temperature of the room e Starting A pressure o
3. afficheur indique nouveau la temp rature ambiante du local ET Nota la modification des deux consignes peut tre faite successivement Les deux consignes ne peuvent pas se chevaucher il y a obligatoirement une zone neutre entre les deux mini 2 C La commande de l air neuf Lorsque les t moins lumineux jaunes des touches et ro sont teints le climatiseur introduit un certain pourcen tage d air neuf r glementaire air ext rieur Ce pourcentage est r glable sur le climatiseur Nota Lorsque le climatiseur est arr t les volets d air neuf sont automati quement ferm s e Fonction fermeture des volets air neuf En pressant la touche le t moin lumineux jaune s al lume L introduction d air neuf est supprim e Cette fonction peut tre utilis e par exemple le soir au moment de la ferme ture du magasin et surtout en p riode hivernale par conomie d nergie Control of desired ambient temperature You can set two ambient temperatures One temperature for heating operation winter and one temperature for cooling operation summer e Setting of heating operation temperature Press key CE its yellow indicator lamp illuminates The green indicator lamp z o flashes if the green indicator lamp o flashes then press key h o The green indicator xx o Will flash The display panel Eli gives the setting temperature for heating To increase or decrease press key Ca orf The setting temp
4. cold cooling y o Economizer When this indicator lamp is illuminated the air conditioner cools the room with the external air free cooling Ea o Extraction When this indicator lamp is illuminated the air conditioner extracts the stale air from the room in the case where this option is installed Faults warning lamps 5o o Filters fouling The red warning lamp indicates the fouling of filters and the requirement to clean them the filter must be clean this is essential for the satisfactory operation of the unit Check regularly its aspect in order to define the cleaning inter vals These intervals will vary according to the type of room we advise you to have a set of replacement filters o Call for technician The red warning lamp indicates that the air conditioner is stopped on faulty You must call your installer to have him do a diagnosis CULOZ PARIS AVENUE JEAN FALCONNIER B P 14 01350 CULOZ d i 83 RUE DE VILLIERS 92523 NEUILLY S SEINE T l phone 79 42 42 42 T l copie 79 42 42 11 T l phone 16 1 47 58 11 66 T l copie 16 1 47 45 63 12 SERVICE EXPORTATION 01350 CULOZ FRANCE S A AU CAPITAL DE 130 000 000 DE F T l phone 79 42 42 20 T lex 980 458 F Compagnie Industrielle d Applications Thermiques R C S BELLEY B 545 620 114
5. ats de d fauts se o Encrassement filtre Le t moin lumineux rouge signale l encrassement des filtres Il faut les nettoyer le filtre doit tre propre il est indispensable au bon fonctionnement de l appareil Examiner r guli rement l aspect de celui ci afin de d finir la p riodicit de son nettoyage Cette p riodicit sera variable suivant la nature des locaux nous vous conseillons d avoir un jeu de filtres propres pour le remplacement o Appel technicien Le t moin lumineux rouge signale que le climatiseur est arr t sur d faut Vous devez faire appel votre installateur afin que celui ci effectue un diagnostic e Fresh air dampers opening operation By pressing key the yellow indicator lamp illuminates The fresh air introduction is increased This function can be used for example during stores rush hours or to eliminate bad smells Attention this function must be used momentarily To econo mize energy remember to return to standard operation Indicator lamps test function Press key to check that all the indicator lamps are in good order e Description of indicator lamps Indicator lamps of operating status Go Ventilation When this indicator lamp is illuminated the discharge fan is operating 3 o Heating When this indicator lamp is illuminated the air conditioner pro duces heat heating ko Cooling When this indicator lamp is illuminated the air conditioner pro duces
6. erature for heating varies 0 5 C After having selected the setting temperature desired for heating and press again key to store it Its indicator lamp goes off the symbol 3 o indicator lamp no longer flashes The display panel gives once more the ambient room temperature e Setting of cooling operation temperature Press key Do its yellow indicator lamp illuminates The green indicator lamp o flashes If the green indicator lamp 3 o flashes then press key the green indicator lamp x o will flash The display panel gives the setting temperature for cooling To increase or decrease press key or and the setting temperature for cooling varies 0 5 C After having selected the setting temperature desired for cooling and press again key to store it lts indicator lamp switches off The indicator lamp o no longer flashes The display panel gives once more the ambient temperature of the room ET Note the two settings can be modified one after the other There is a compulsory neutral zone in between the two settings they cannot overlap Fresh air control When the yellow indicator lamps of keys and ro are off the air conditioner introduces a standard per centage of fresh air external air This percentage can be adjusted on the air conditioner Note When the air conditioner is off the fresh air dampers clos automati cally e Fresh air dampers closing operation When pressing key
7. fra chissement t e R glage de la temp rature fonction chauffage Presser la touche Son t moin lumineux jaune s allume Le t moin lumineux vert o clignote Si c est le voyant vert o qui clignote alors appuyer sur la touche Le t moin lumineux vert z o clignotera L afficheur indique la temp rature de consigne chaud Pour modifier la hausse ou la baisse appuyer sur les touches et La temp rature de consigne chaud varie de 0 5 C en 0 5 C Lorsque vous avez r gl la temp rature de consigne chaud d sir e m moriser la en pressant une nouvelle fois la touche 4 o Son voyant lumineux s teint Le voyant lumineux zx one cli gnote plus L afficheur indique nouveau la temp rature ambiante du local BEN e R glage de la temp rature fonction froid Presser la touche Son t moin lumineux jaune s allume Le t moin lumineux vertak o clignote Si c est le voyant vert 3x o qui clignote alors appuyer sur la touche ko le t moin lumineux vertak o clignotera L afficheur indique la temp rature de consigne froid Pour modifier la hausse ou la baisse appuyer sur les tou ches J et Z et la temp rature de consigne froid varie de 0 5 C en 0 5 C Lorsque vous avez r gl la temp ra ture de consigne froid d sir e m moriser la en pressant une nouvelle fois la touche 0 le Son voyant lumineux s teint Le voyant lumineux o ne cli gnote plus L
8. n key starts the discharge fan The yellow indicator lamp and green indicator lamp Go illuminate e Stopping A second pressure on key stops the discharge fan The yellow indicator lamp and green indicator lamp Go switch off Operating mode e Ventilation only Press key only the discharge fan runs The yellow et and green indicator lamps o illumi nate e Heating only The discharge fan must run Press key its yellow indicator lamp illuminates The key indicator lamp must be off In this case the air conditioner will only produce heating if nec essary To cancel press again on key h o then the discharge fan alone will run e Cooling only The discharge fan must run Press key x o its yellow indicator lamp illuminates The key indicator lamp must be off In this case the air conditioner will only produce cooling if nec essary To cancel press again key 3 o then the discharge fan alone will run e Automatic heating and cooling The discharge fan must run Press keys 3e o and o their yellow indicator lamps illu ninate In this case the air conditioner will produce heating or cooling automatically according to requirements To cancel press again keys and then the dis charge fan alone will run R glage de la temp rature ambiante d sir e Vous pouvez r gler deux temp ratures ambiante Une temp rature pour fonction chauffage hiver et une temp rature pour fonction ra
9. s 5 Touches de r glage des consignes de temp rature 6 Signalisation du fonctionnement chauffage 7 Signalisation du fonctionnement rafra chissement 8 Signalisation du fonctionnement rafra chissement gratuit 9 Signalisation du fonctionnement ventilateur soufflage 10 Affichage de la temp rature ambiante du local 11 Signalisation du fonctionnement de l extraction 12 Signalisation de l encrassement filtres 13 Signalisation climatiseur en d faut 14 Touche fermeture volets air neuf 15 Touche ouverture volets air neuf 10 11 12 13 14 15 Description Run stop key with display Cooling function key with display Heating function key with display Lamp test key Temperature setting control keys Heating operation display Cooling operation display Free cooling operation display Discharge fan operation display Temperature display Extraction operation display Filters fouling display Air conditioner fault display Fresh air dampers closing key Fresh air dampers opening key Instructions d utilisation L afficheur 240 indique en permanence la temp rature ambiante du local e Mise en marche Une pression sur la touche met en marche le ventila teur de soufflage Le t moin lumineux jaune et le t moin lumineux vert Go s allument e Arr t Une seconde pression sur la touche arr te le ventila teur de soufflage Les t moins lumineux jaune et le t
10. the yellow indicator lamp illumi nates Fresh air introduction is cancelled This function can be used for example at night when closing the store and particu larly during the winter period to economize energy e Fonction ouverture des volets air neuf En pressant la touche Ho le t moin lumineux jaune s al lume L introduction d air neuf est augment e Cette fonction peut tre utilis e par exemple lors d une affluence subite de clients ou bien pour vacuer de mauvaises odeurs Attention cette fonction doit tre utilis e momentan ment Pensez revenir au fonctionnement normal ceci dans un souci d conomie d nergie Fonction test des t moins lumineux Presser la touche pour v rifier la validit de tous les t moins lumineux e Descriptions des t moins lumineux T moins lumineux des tats de fonctionnement Go Ventilation Lorsque ce t moin est allum le ventilateur de soufflage fonc tionne 3 o Chaud Lorsque ce t moin est allum le climatiseur produit du chaud chauffage o Froid Lorsque ce t moin est allum le climatiseur produit du froid rafra chissement Y Jo Economiseur Lorsque ce t moin est allum le climatiseur rafra chi le local avec l air ext rieur rafra chissement gratuit 70 Extraction Lorsque ce t moin est allum le climatiseur extrait l air vici du local dans le cas o cette option est install e T moins lumineux des t

Download Pdf Manuals

image

Related Search

Related Contents

ServoCenter 4.1 MINI Manual Volume 1  Electrolux B425MR User's Manual  Samsung RF9900H FDR with Chef Mode, 34.3 cu. ft. User Manual  取扱説明書  10 MB 26th Sep 2013 Genie Sphinx4 Software User Manual  Samsung SGH-X160 Lietotāja rokasgrāmata  POSP Manual - Kalinka Optics  wireless door activated light switch  Manual de Instalación  4471 - micro light indoor - DE - EN - FR  

Copyright © All rights reserved.
Failed to retrieve file