Home
AFD Phoenix and Mariposa Outdoor Fireplace
Contents
1. NECLAR 7 3 DA IMPORTANT SAFETY INFORMATION BE CAREFUL If not installed and used correctly per these instructions this product can cause serious injury CAUTION Installation and maintenance must be done by an NFI Certified or other qualified professional service technician Read these instructions before installing this fireplace and the R H P gas appliance Be sure you understand all safety precautions and warnings contained in this manual and the appliance owner s manual FOR OUTDOOR USE ONLY When shutting the gas appliance down be sure to TURN THE CONTROL VALVE OR KEY FULLY OFF WARNING CARBON MONOXIDE POISONING MAY LEADTO DEATH DO NOT MODIFYTHIS FIREPLACE OR THE GAS APPLIANCE EXCEPT AS PROVIDED FOR IN THE MANUALS Any other change may be dangerous Improper installation or use of the fireplace and R H P gas appliance can cause serious injury or death from fire burns explosions or carbon monoxide poisoning Check state and local codes to determine if the fireplace and R H P gas appliance are permitted in your locality before installation Manual models allows for an adjustable flame height THESE SETTINGS MUST ALWAYS BE HIGH ENOUGH FORTHE FLAME TO BE CLEARLY VISIBLE WHEN LIGHTING THE APPLIANCE ALWAYS LIGHT ON HIGH FIREPLACE INSTALLATION BEFORE YOU BEGIN Important Prior to installation ensure that all specifications dimensions and minimum clearances stated in this manual are ob
2. Si vous sentez une odeur de gaz 1 Coupez le gaz l appareil 2 teindre toute flamme nue 3 Si l odeur persiste loignez vous de l appareil et appelez imm diatement votre fournisseur de gaz ou les pompiers L installation et le service doivent tre assur s par un NFI certifi ou toute autre installateur agence de service ou fournisseur professionnelle qualifi e de gaz DANGER CARBON MONOXIDE HAZARD Un foyer gaz ventil peut produire du monoxyde de carbone qui n a pas d odeur Son utilisation dans un espace clos peut vous tuer Ne jamais utiliser l appareil dans un espace clos tel qu une caravane tente voiture ou la maison REV 1 1411101350 d INSTALLATEUR CONSOMMATEUR Ces instructions DOIVENT tre maintenues avec cet appareil pour la future r f rence Important Lisez ces instructions soigneusement avant de commencer l installation de l unit AVERTISSEMENT L installation l ajustement le changement le service ou l entretien inexact peuvent causer des d gats mat riels le dommage corporel ou des pertes humaines Lisez l installation l op ration et les instructions d entretien compl tement avant d installer ou entretenir cet quipement Le R H P Appareil gaz est con u comme un appareil assist Les adultes doivent tre pr sents lorsque l appareil est en marche Ne laissez pas l appareil est en marche sans surveillance Si le pro
3. d crit comme type I dans la norme d finie dans le e de paragraphe ci dessus Ce dispositif est g n ralement d crit comme coupleur rapide de fil de point culminant Si votre cylindre de gaz de propane vient avec une prise de la poussi re placez le bouchon anti poussi re sur la Sortie de valve de cylindre toutes les fois que le cylindre n est pas en service OP RATION DE COUPLEUR RAPIDE Pour relier le regulator hose l ajustage de pr cision de valve de cylindre de gaz de propane Serrez l crou de main sur le r gulateur au dessus de l ajustage de pr cision de fil de point culminant sur la valve de cylindre Tournez l crou de main dans le sens des aiguilles d une montre pour engager les fils et pour serrer jusqu ce que douillettement L utilisation des pinces ou de la cl ne devrait pas tre n cessaire Seulement le propane marqu par cylindres doit tre employ Pour d brancher Tournez l crou de main dans le sens contraire des aiguilles d une montre jusqu isol fig 6 1 Important Avant d employer le gril et ensuite chaque fois que le cylindre est enlev et rattach examinez tous les raccordements pour d celer les fuites Arr tez les valves de gril et ouvrez la valve principale de cylindre puis v rifiez les raccordements avec de l eau savonneux R parez toutes les fuites avant d allumer le gril ATTENTION Tournez toujours la valve principale de cylindre de propane au loin apr s chaque
4. NOT install or use this appliance inside a building garage or any other enclosed area including recreational vehicles and or boats THIS UNIT MUST BE INSTALLED IN SUCH A MANNER THAT ALL VENT OPENINGS ON THE FIREPLACE REMAIN CLEAR AND FREE OF ALL OBSTRUCTIONS AT ALL TIMES AND DURING ALL WEATHER CONDITIONS SOLID FUEL MUST NOT BE BURNED in the fireplace CHECK GAS TYPE natural gas or propane The gas supply you intend to use may not be the same as that stated on the burner rating plate as purchased If the gas supply is different DO NOT INSTALL and contact the dealer for assistance FOR NATURAL GAS The minimum inlet gas supply pressure for purposes of input adjustment is 5 water column w c and the maximum inlet gas supply pressure is 10 5 w c FOR PROPANE GAS The minimum inlet gas supply pressure for purposes of input adjustment is 8 w c and the maximum inlet gas supply pressure is 13 w c DO NOT INSTALL THE GAS APPLIANCE IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED The gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue pressure loss will occur if the pipe is too small or the run is too long Gas supply pipe must be 1 2 minimum interior diameter If the gas line is longer than 20 a larger diameter line may be necessary Refer to the NFPA 54 guidelines for further details For installations at elevations above 2 000
5. Unvented 5 pc set Body Mantel Hardware kits Body T Hardware kits Hearth t t 113 Extended Bullnose 137 Extended Bullnose 160 Extended Bullnose Corner Square Edge AR ae not shown T each kit contains 1 1 2 13 x 3 5 bolt 1 nut 2 washers t only required included with multi piece large hearths Phoenix w Back Venting Vented Fireplace w 16 Radiused Bullnose Hearth shown design of your model may slightly vary PARTS LIST cont Description IDENTIFICATION PARTS LIST Hearth assembly 113 Extended Bullnose Grand Phoenix 818 118 Hearth assembly 137 Extended Bullnose rand Mari 168 Hearth assembly 160 Extended Bullnose Grand Ma posa 868 Hearth assembly Corner Square Edge Firebox liners Vented 4 pc set Firebox liners Unvented 5 pc set Body Chimney Vented Chimney Unvented Side wall Front Side wall Rear Side wall End Side wall Top Hardware kits Body t Hardware kits Hearth T 113 Extended Bullnose 137 Extended Bullnose 160 Extended Bullnose Corner Square Edge PO NM DMO N HH HH Lll not shown T each kit contains 1 1 2 13 x 3 5 bolt 1 nut 2 washers 9 Grand Mariposa Vented Fireplace w 113 Extended Bullnose Hearth shown design of your model may slightly vary REN SY QR gt
6. d compression eem Ecrou de main avec le fil de point culminant PEN Passage a SAFE USE amp MAINTENANCE OF PROPANE GAS CYLINDERS IMPORTANT FOR YOUR SAFETY READ AND FOLLOW ALL WARNINGS PROVIDED WITH THE PROPANE GAS CYLINDER When operating this appliance with a propane gas cylinder these instructions and warnings MUST be observed FAILURE TO DO SO MAY RESULT IN A SERIOUS FIRE OR EXPLOSION CYLINDER CONNECTOR REQUIREMENTS Propane gas cylinders valves and hoses must be maintained in good condition and must be replaced if there is visible damage to either the cylinder or valve If the hose is cut or shows excessive abrasion or wear it must be replaced before using the gas appliance see e This unit when used with a cylinder should be connected to a standard 5 gallon 20 Ib propane gas cylinder equipped with an OPD Overfill Prevention Device The OPD has been required on all cylinders sold since October 1 1998 to prevent overfilling Cylinder dimensions should be approximately 12 30 5 cm in diameter and 18 45 7 cm high Cylinders must be constructed and marked in accordance with the Specifications for Propane Gas Cylinders of the U S Department of Transportation D O T or the National Standard of Canada CAN CSA B339 Cylinders Spheres and Tubes for Transportation of Dangerous Goods The oylinder used must include a collar to protect the cylinder valve and the cyl
7. found on the left or right side of the fireplace and turning the valve clockwise toward the OFF position until it no longer rotates Be sure the control knob is turned fully off to avoid any gas leakage SERVICING AND CLEANING Each installation site for any unit presents its own unique combustion environment Specific factors such as weather wind currents yard debris altitude drafts the size of the surrounding area all have an influence on the proper operation of the gas appliance A normally operating appliance will demonstrate the following characteristics e A lively realistic yellow flame Odor free If the flame is not clean identifiable by excessive sooting on the decorative media refer to the information below Some soot on the media may occur and should not be a concern unless excessive Cover your fireplace opening with a screen protector plate whenever it is not in use and follow the guidelines below at least annually ANNUAL CLEAN INSPECTION GUIDELINES The fireplace gas appliance and installation must be inspected annually Refer to these instructions and the appliance owner s manual for details Performing these procedures will ensure proper operation appearance and safety WEAR GLOVES If maintenance is required it must be done by a qualified professional service technician Always shut off the gas to the appliance while performing service work Allow the appliance to cool before servicing The entir
8. ft contact your local dealer or gas supplier before installing Input ratings should be reduced approximately 496 for each 1 000 ft above sea level Refer to the National Fuel Gas Code The gas appliance and the individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa This is accomplished by closing the gas supply line valve The unit must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa When a gas appliance is for connection to a fixed piping system the installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 International Fuel Gas Code Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 as applicable The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 if applicable INSTALLER NOTE This unit should be installed so that it can be removed if service is required GAS SUPPLY PLUMBING REQUIREMENTS Apply only joint compounds that are resistant to all gasses on all male pipe fitti
9. or dealer NEVER USE A FLAME TO CHECK FOR LEAKS OPTIONAL ACCESSORIES OPTIONAL GFRC CHIMNEY RAIN VENT CAP An optional GFRC chimney rain vent cap is available to protect your unit from the rain Contact your local dealer for ordering information To place the cap allow the unit to cool completely then place as shown in Fig 23 1 The cap can be in place during operation Note This cap is not applicable to Phoenix w Back Venting models OPTIONAL SCROLL SCREEN An optional scroll screen is available to protect your unit and to provide a decorative addition Contact your local dealer for ordering information To install allow the unit to cool completely position the top of the screen into the top of the firebox opening then lower the bottom of the screen until it rests in place See Fig 23 2 The scroll screen can be in place during operation OPTIONAL GFRC PROTECTOR PLATE An optional GFRC protector plate is available to protect your unit and to provide a decorative addition when not in use Contact your local dealer for ordering information To install allow the unit to cool completely position the top of the plate into the top of the firebox opening then lower the bottom of the plate until it rests in place See Fig 23 3 J nt Fig 23 3 GFRC protector plate placement DIRECTIVES DE L ECLAIRAGE POUR VOTRE S CURIT LIRE AVANT D ALLUMER AVERT
10. top side wall piece onto the front and rear side walls as shown in Fig 20 4 no hardware required This will secure the entire side wall Repeat assembly for the opposite side Side Walls CHA NU ER Hardware e WA Bolts x 3 Fig 20 1 Assemble rear side wall skip if n a Hardware Bolts x 2 Fig 20 4 Assemble top side wall skip if n a FIREPLACE INSTALLATION cont Liners amp Chimney Mantel See Fig 21 2 for Vented Phoenix 1 Install the firebox liners into the interior of the firebox w Back Venting Liner Details in the order shown in Fig 21 1 or Fig 21 2 depending on your model Unvented fireplaces contain a liner for the Fig 21 1 Phoenix amp Mariposa models with Chimneys top of the firebox and ALL unvented models Fig 21 2 Vented Phoenix w Back Venting models The bottom and rear liners have grooves to assist in placement The two shims D are to be installed by hand as shown Be sure to pull the flex connector inside of the fireplace body through the liner and into the open interior of the firebox for later R H P burner installation Ensure the unit s marking label plate is placed behind the side liner during installation It is located in the interior of the firebox and hangs from a chain on the front inner wall valve side For Unvented amp Phoenix w Back Venting Fireplaces An additi
11. tournant la vanne dans le sens horaire vers la position OFF jusqu ce qu il ne tourne plus Assurez vous que le bouton de commande est tourn compl tement hors d viter toute fuite de gaz LIGHTING GUIDELINES FOR YOUR SAFETY READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE A BEFORE LIGHTING smell all around the unit area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor B WHAT TO DO IF YOU SMELL GAS 1 Shut off the gas to the appliance 2 Extinguish any open flame 3 If odor continues immediately call your gas supplier or the fire department C Use only your hand to push in or turn the gas control knob on the appliance Never use tools If the knob will not push in or turn by hand DO NOT try to repair it Call a qualified professional service technician Force or attempted repair may result in fire or explosion TO LIGHT THE APPLIANCE 1 STOP Read the safety information above 2 Follow the lighting instructions found in the owner s manual provided with your R H P gas appliance TO SHUT OFF GAS TO THE APPLIANCE To extinguish your gas appliance follow the shut off instructions found in the owner s manual provided with your R H P gas appliance If required the gas can be immediately shut off by inserting the key into the key valve
12. utilisation et avant de d placer le gril et le cylindre ou d brancher l accouplement Cette valve doit rester ferm e et le cylindre a d branch alors que l appareil n est pas en service quoique l coulement de gaz soit arr t par un dispositif de s ret quand le coupleur est d branch Inspectez soigneusement l ensemble de tuyau chaque fois avant que le gaz soit allum Un tuyau fissur ou effiloch doit tre imm diatement remplac Sil appareil est stock l int rieur le cylindre doit tre disconnected et a enlev Des cylindres Disconnected doivent tre stock s dehors hors de la port e des enfants avec les prises de valve filet es troitement install es et ne doivent pas tre stock s dans un b timent le garage ou n importe quel autre secteur inclus POUR VOTRE S RET a Ne stockez pas un cylindre de gaz disponible de propane dessous ou ne vous approchez pas de cet appareil b Neremplissez jamais cylindre au del de 80 pour cent de plein c SI INFORMATION DANS A ET B N EST PAS SUIVIE EXACTEMENT UN FEU CAUSANT LA MORT OU DES DOMMAGES SERIEUX PEUT SE PRODUIRE Fig 6 1 type coupleur rapide de fil de point culminant d l Ajustage de pr cision en laiton de fil de 3 4 point culminant Volant de commande EE i R gulateur ndicateur de niveau de liquide 0 facultatif AA4A4AAAAAAAA
13. ISSEMENT SIVOUS NE SUIVEZ PAS CES INSTRUCTIONS LA LETTRE UN INCENDIE OU UNE EXPLOSION POURRAIENT S ENSUIVRE CAUSANT DES DOMMAGES MATERIELS DES BLESSURES OU DES PERTES DE VIE AVANT D ALLUMER sentez tout autour de l unit de surface pour le gaz Assurez vous de sentir pr s du plancher car certains gaz sont plus lourds que l air et se d posent sur le sol QUE FAIRE SI UNE ODEUR DE GAZ 1 Coupez le gaz l appareil 2 teindre toute flamme nue 3 Sil odeur persiste appelez imm diatement votre fournisseur de gaz ou le service des incendies Utilisez seulement votre main pour enfoncer ou tourner le bouton de commande de gaz sur l appareil Ne jamais utiliser d outils Si le bouton ne sera pas enfoncer ou tourner la main NE PAS essayer de le r parer Appelez un technicien de service qualifi Force ou une tentative de r paration pourrait provoquer un incendie ou une explosion D ALLUMER L APPAREIL 1 ARR T Lisez les consignes de s curit ci dessus 2 Suivezles instructions d allumage figurant dans le manuel du propri taire fourni avec votre RHP Dispositif x a gaz POUR ARRETER LE GAZ A L APPAREIL Pour teindre votre appareil gaz suivez les instructions d arr t figurant dans le manuel du propri taire fourni avec votre appareil gaz RHP Si n cessaire le gaz peut tre imm diatement arr t en ins rant la cl dans la vanne cl qui se trouve sur le c t gauche ou droit de la chemin e et en
14. LINES LEAK TEST OPTIONAL ACCESSORIES OPTIONAL GFRC CHIMNEY RAIN VENT CAP OPTIONAL SCROLL SCREEN OPTIONAL GFRC PROTECTOR PLATE USE CARE amp SERVICE LIGHTING GUIDELINES FOR YOUR SAFETY READ BEFORE LIGHTING TO LIGHT THE APPLIANCE TO SHUT OFF GAS TO THE APPLIANCE SERVICING AND CLEANING ANNUAL CLEAN INSPECTION GUIDELINES CONCRETE CARE TROUBLESHOOTING WARRANTY IMPORTANT SAFETY INFORMATION Congratulations on your purchase of an American Fyre Designs outdoor gas fireplace Made with pride in America your new fireplace complies with national safety standards and when installed per these instructions and used as intended it will provide warmth and comfort to your outdoor area for many years Prior to installation and operation ensure that all specifications dimensions and minimum clearances stated in this manual are observed You must read all warnings and safety information and understand all of the information in this manual All installation requirements must be observed and met REV 1 1411101350 3 L H2 011 PRE INSTALLATION AND PREPARATION SAFETY GUIDELINES This fireplace is designed to be installed with select R H P vented unvented gas appliances The following 3 sections of warnings apply to this complete setup type A Before installing this unit check the MINIMUM CLEARANCE TO COMBUSTIBLES section to ensure that the surrounding area is properly sized for the installation The unit is for outdoor use only DO
15. T install vented fireplaces under any overhead combustible materials DO NOT install unvented fireplaces under any overhead combustible materials that are less than 3 feet above the top of the unit E Ensure that the fireplace is installed on a hard and level surface Ensure that the fireplace is installed in such a manner that all vent openings on the fireplace remain clear and free of all obstructions at all times and during all weather conditions Due to high temperatures the fireplace must be located out of traffic areas and away from combustibles OPERATING THE UNIT SAFELY AND CORRECTLY The R H P burner is a decorative gas appliance It is not a cooking appliance SOLID FUEL MUST NOT BE BURNED in the fireplace When shutting the appliance down be sure to TURN THE CONTROL VALVE FULLY OFF Children MUST be carefully supervised when they are in the area of this fireplace DO NOT sit or place any part of the body clothing or other flammable materials on or near the fireplace surround Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid burns or clothing ignition DO NOT lean into the fireplace when lighting or when in use Every time you use the fireplace and appliance make sure that The area around the fireplace is clear and free from combustible materials gasoline and other flammable vapors and liquids There is no blockage of t
16. This warranty does not cover breakage in shipment from our Independent distributor to its customer if the damage is determined to have occurred during that shipment This warranty specifically excludes liability for indirect incidental or consequential damages Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion may not apply to you This warranty gives you specified legal rights and you may have other rights that vary from state to state or province For additional information regarding this warranty or to place a warranty claim contact the R H Peterson dealer where the product was purchased TO REGISTER YOUR PRODUCT ONLINE GO TO WWW RHPETERSON COM AND CLICK ON PRODUCT REGISTRATION THANK YOU FOR YOUR PURCHASE Quality Check Model Serial Inspector Robert H Peterson Co 14724 East Proctor Avenue City of Industry CA 91746
17. UENCE UNE INCENDIE OU UNE EXPLOSION SERIEUSE CYLINDRE ET CONDITIONS ET CARACTERISTIQUES DE CONNECTEUR a Des cylindres et les valves de gaz de propane doivent tre maintenus en bon tat et doivent tre remplac s s il y a des dommages vidents au cylindre ou la valve Ce gril une fois utilis avec un cylindre devrait tre reli un gallon de la norme 5 201b cylindre de gaz de propane quip d un OPD remplissez au dessus du niveau le dispositif d emp chement LOPD a t exig sur tous les cylindres vendus depuis octobre 1 1998 pour emp cher le remplissage excessif Les dimensions de cylindre devraient tre approximativement 12 30 5cm de diam tre et 18 45 7cm hauts Des cylindres doivent tre construits et marqu s selon les caract ristiques pour des cylindres de gaz de propane du d partement des ETATS UNIS du transport D O T ou le niveau national du Canada du CAN CSA B339 des cylindres des sph res et des tubes pour le transport des marchandises dangereuses Le cylindre doit inclure un collier pour prot ger la valve de cylindre et le circuit d alimentation de cylindre doit tre assur le retrait de vapeur Le r gulateur de pression et l ensemble de tuyau utilis doivent assortir les sp cifications pour le type par ANSI Z 21 58 2005 CGA 1 6 2005 voir la figue 6 1 La valve de cylindre de gaz de propane doit tre quip e d un dispositif d accouplement de raccordement de cylindre
18. as applicable key valve location For rear installs see Fig 19 1 may vary For underneath installs see Fig 19 2 Observe all codes and ensure all appropriate connections are used to properly connect the gas supply Apply only joint compounds that are resistant to all gasses to all male pipe Flex fittings except flare fittings Make sure to tighten every joint connector securely and properly leak test at all connections na Connect here Important This fireplace does not accommodate from below propane cylinders If a cylinder is used it must a be located in a safe location Fig 19 2 Route gas supply underneath install FIREPLACE INSTALLATION cont For standard models proceed to the LINERS amp CHIMNEY MANTEL section For Grand models continue on to the following section Grand Models ONLY Side Walls 1 Locate the four pieces required to assemble onecomplete side wall Place the rear side wall piece beside the fireplace body as shown Carefully align the pilot holes and repeat the hardware installation process See Fig 20 1 Place the front side wall piece beside the fireplace body as shown Carefully align the pilot holes and repeat the hardware installation process See Fig 20 2 Place the end side wall piece against the front and rear side walls as shown in Fig 20 3 no hardware required Slide the
19. by the National Fireplace Institute NFI as CERTIFIED NFI Gas Specialists Gas Appliances WARNING For Outdoor Use Only PHOENIX amp MARIPOSA OUTDOOR FIREPLACES INSTALLER amp CONSUMER These instructions MUST be retained with this unit for future reference Important Read these instructions carefully before starting installation of the unit WARNING Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment The R H P gas appliance is designed as an attended appliance Adults must be present when the unit is operating DO NOT leave the unit burning when unattended If the product is left burning unattended it may cause damage or serious injury IMPORTANT For safe operation and proper performance of this product and to comply with certification listings and building code acceptances use ONLY Robert H Peterson R H P controls parts and accessories that have been specifically listed or certified for use with this fireplace Use of other controls parts or accessories is prohibited and will void all warranties certifications listings and building code approvals and may cause property damage personal injury and loss of life CODE AND SUPPLY REQUIREMENTS The gas installation must c
20. duit est laiss br ler sans surveillance il peut causer des dommages ou des blessures graves IMPORTANT Pour un fonctionnement s r et une bonne performance de ce produit et de se conformer la certification les annonces et les acceptations du code du b timent utiliser uniquement des contr les Robert H Peterson R H P les pi ces et accessoires qui ont t sp cifiquement num r s ou certifi es pour une utilisation avec ce foyer L utilisation d autres commandes pi ces ou accessoires est interdite et videra toutes les garanties certifications listes et approbations de codes du b timent et peut causer des d gats mat riels le dommage corporel et des pertes humaines CONDITIONS DE CODE ET D APPROVISIONNEMENT L installation de gaz doit se conformer aux codes locaux et aux ordonnances ou en l absence des codes locaux au plus d funt code national de gaz de carburant la norme ANSI 2223 1 L H2 011 TABLE OF CONTENTS GETTING STARTED PRE INSTALLATION AND PREPARATION SAFETY GUIDELINES INSTALLATION SAFETY GUIDELINES OPERATING THE UNIT SAFELY AND CORRECTLY SAFE USE amp MAINTENANCE OF PROPANE GAS CYLINDERS NOTES PAGE SPECIFICATIONS AND DIMENSIONS MINIMUM CLEARANCES TO COMBUSTIBLES PARTS LIST INSTALLATION IMPORTANT SAFETY INFORMATION FIREPLACE INSTALLATION BEFORE YOU BEGIN LOCATION FIREPLACE ASSEMBLY OVERVIEW FIREPLACE ASSEMBLY STEP BY STEP BURNER INSTALLATION BURNER INSTALLATION GUIDE
21. e appliance should be inspected regularly Excessive debris can build up on the fireplace or appliance from leaves dirt or other debris It is critical that all control components burners vent openings and the surrounding area be kept clean and free of all obstructions Examine that all components are properly assembled installed as instructed in this manual and the appliance owner s manual Ensure that all decorative media is properly placed as instructed in the appliance owner s manual The appliance must be replaced prior to being put into operation if it is evident that the appliance is damaged Contact your local dealer for replacement parts DO NOT use substitute materials when replacing any components of the fireplace or appliance Keep the vent openings and surrounding area of the of the fireplace clean and free of obstructions at all times Periodically perform visual checks of the burner flames The burner flames should be blue at the base with a combination of blue yellow at the body and tips Contact a qualified professional service technician for maintenance To maintain the concrete components see the CONCRETE CARE section for details Any guard or other protective device removed for servicing the appliance shall be replaced prior to operating the appliance Verify proper operation after servicing CAUTION HOT DURING OPERATION AND AFTER USE Children must be supervised when in the vicinity of this fireplace Serio
22. f AMERICAN C RE DESIGNS INSTALLATION amp OWNER S MANUAL by RH Peterson co 017 series shown ANSI Z21 97 CSA 2 41 for outdoor decorative gas when installed with select R H P Vented Unvented WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance A propane cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department Installation and service must be performed by an NFI Certified or other qualified professional installer service agency or gas supplier DANGER CARBON MONOXIDE HAZARD A vented gas appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use the appliance in an enclosed space such as a camper tent car or home Vented Series 015 017 073 818 868 Unvented Series 115 117 173 118 168 SF F14 023 Complies with NATIONAL NATIONAL We recommend that our gas INSTITUTE hearth products be installed appliances the U S
23. he airflow through the vent openings located on the fireplace The hose is inspected if applicable See the SAFE USE amp MAINTENANCE OF PROPANE GAS CYLINDERS section WARNING HOT WHILE IN OPERATION AND FOLLOWING OPERATION Serious injury can occur DO NOT throw trash paper or other flammable materials into the fireplace DO NOT leave in operation when unattended WARNING DO NOT operate this fireplace and appliance in the rain WARNING DO NOT operate this fireplace and appliance in high wind conditions DO NOT continue using if you smell unusual odors or have headaches nausea or dizziness DO NOT store any combustible materials gasoline and any other flammable vapors liquids in the vicinity of the fireplace Provide adequate clearance for servicing and operation Matches paper garbage or any other material must not be thrown into the fireplace K DO NOT use the appliance if any part of it has been underwater Immediately call a qualified professional service technician to inspect the appliance and to replace any part of the control system and any gas control that has been underwater UTILISATION SURE ET ENTRETIEN DES CYLINDRES DE GAZ DE PROPANE IMPORTANT POUR VOTRE SURETE LISEZ ET SUIVEZ TOUS LES AVERTISSEMENTS EQUIPES DE VOTRE CYLINDRE DE GAZ DE PROPANE En actionnant cet appareil avec un cylindre de gaz de propane ON DOIT observer ces instructions et avertissements LE MANQUE DE FAIRE AINSI PEUT AVOIR COMME CONSEQ
24. ind the side liner during installation To view simply reach in access then return once done For unvented models and all Phoenix w Back Venting models the top liner panel must be moved to one side MINIMUM CLEARANCES TO COMBUSTIBLES The dimensions shown below are MINIMUM CLEARANCES to maintain when you install the unit ALL CLEARANCES AND INFORMATION STATED HERE MUST BE MAINTAINED AND FOLLOWED Dimension Vented Fireplace Unvented Fireplace Description Side clearance from hearth extension to combustible construction Clearance above unit N A Clearance below unit OF 6 6 Front clearance from hearth extension to combustible construction 3e Phoenix amp Mariposa w Chimney 6 Phoenix w Back Venting 36 Rear clearance Table 4 Minimum Clearances to Combustibles C Floor must be a hard level surface Combustible materials OK PARTS LIST Your fireplace is packaged onto 1 pallet iMPORTANT yr PS Dg R H P gas appliances are purchased and GOMBONERTS packaged separately Various models are Remove all packing p available material including J ARE HEAVY p R H P gas appliances and replacement parts any protective ff HANDLE WITH CARE p can be ordered from your local American Fyre _ coatings and p Designs dealer discard prior to use LI a a a a Select models are illustrated y
25. inder supply system must be arranged for vapor withdrawal The pressure regulator and hose assembly used must match the specification for Type by ANSI Z 21 58 2005 CGA 1 6 2005 see Fig 7 1 The propane gas cylinder valve must be equipped with a cylinder connection coupling device described as Type I in the standard defined in paragraph e above This device is commonly described as an Acme thread quick coupler If the propane gas cylinder comes with a dust plug place The use of pliers or a wrench should not be necessary Only cylinders marked propane may be used To disconnect Turn the hand nut counterclockwise until detached Fig 7 1 Important CAUTION Before using the unit and after each time the cylinder is removed and reattached check the hose for wear see a and check all connections for leaks Turn off the unit valves and open the main cylinder valve then check connections with soapy water Repair any leaks before lighting the unit Always turn the propane cylinder main valve off after each use and before moving the unit and cylinder or disconnecting the coupling This valve must remain closed and the cylinder disconnected while the appliance is not in use even though the gas flow is stopped by a safety feature when the coupler is disconnected Carefully inspect the hose assembly each time before the gas is turned on A cracked or frayed hose must be replaced immediately If the appliance
26. is stored indoors the cylinder must be disconnected and removed Disconnected cylinders must be stored outdoors out of the reach of children with threaded valve plugs tightly installed and must not be stored in a building garage or any other enclosed area FOR YOUR SAFETY a DO NOT store a spare propane gas cylinder under or near this appliance b NEVER fill the cylinder beyond 80 percent full IF THE INFORMATION IN a AND b IS NOT FOLLOWED EXACTLY A FIRE CAUSING DEATH OR SERIOUS INJURY MAY OCCUR Fig 7 1 Type Acme thread quick coupler acc Hand wheel Brass Acme the dust cap on the cylinder valve outlet whenever the BE o ea cylinder is not in use Valve QUICK COUPLER OPERATION D we _ EO TT Liquid level indicator optional Regulator To connect the regulator hose assembly to the propane gas cylinder valve fitting Press the hand nut on the regulator over the Acme thread fitting on the cylinder valve Turn the hand nut clockwise to engage the threads and tighten until snug Adhd AAAAAAA Hand nut with Acme thread wa NOTES PAGE Please use this page to record any information that you may want to have at hand SPECIFICATIONS AND DIMENSIONS Fireplace Style Dimensions Weight Pieces Phoenix Fireplace 017 amp 117 855 wy x 7 Gl x X n 1100 lbs 7 pcs Phoen
27. ix w Back Venting Fireplace 015 amp 115 65 w x 37 d x 57 h 900 Ibs 8 pcs Grand Phoenix Fireplace 818 amp 118 t ie y x 877 Cl x 87 h 1400 Ibs 15 pcs Mariposa Fireplace 073 amp 173 65 w x 37 d x 67 h 970 lbs 7 pcs Grand Mariposa Fireplace 868 amp 168 t 113 w x 37 d x 67 h 1300 Ibs 15 pcs Dimensions Weight amp Pieces listed based upon a standard 16 Radiused Bullnose Hearth T Dimensions Weight amp Pieces listed based upon an 113 Extended Bullnose Hearth Table 1 Overall Product Dimensions 2 Recess Option The above fireplaces except Grand models are offered with a 2 recess option This results in certain areas of the fireplace flat surfaces of the body and or hearth being recessed inward These reduced dimensions allow for a custom substrate i e tiles stonework to be installed Contact your local American Fyre Designs dealer for further details Select Models Shown your model may vary Grand Mariposa Fireplace SPECIFICATIONS AND DIMENSIONS cont Hearth Style Dimensions 16 Radiused Bullnose Hearth 65 w x 37 d x 16 h 16 Rectangle Bullnose Hearth 65 w x 36 d x 16 h 16 Roundover Hearth ARE RES TS 4 Roundover Hearth 52 w x 32 d x 4 h 113 Extended Bullnose Hearth Er wr xe ex cl xc WG Ir 137 Extended Bullnose Hearth 137 w x 37 d x 16 h 160 Extended Bullnose Hearth 160 w x 37 d x 16 h Co
28. l and hearth selected The Phoenix w Back Venting model has a mantel in place of the chimney Grand models have the addition of side walls which are addressed in the following step by step section This section is just an overview refer to the following step by step section for complete assembly and installation details ASSEMBLY INSTALL OVERVIEW 1 Place Assemble hearth 2 Attach body 3 Connect gas not shown 4 Attach side walls Grand models only not shown Install firebox liners Place chimney mantel Install burner not shown Phoenix Fireplace w 16 Radiused Bullnose Hearth shown Fig 17 1 Overall Orientation One piece hearth shown here Multi piece hearths require assembly FIREPLACE INSTALLATION cont FIREPLACE ASSEMBLY STEP BY STEP CAUTION Fireplace components are heavy CAREFULLY handle all components during assembly Note A Phoenix Fireplace with a 16 Radiused Bullnose Hearth is primarily depicted here Your assembly may slightly vary depending on model and hearth selected Hearth and Body 1 Locate the hearth or hearth pieces in an appropriate location refer back to the LOCATION section if needed For one piece hearths step 2 is not applicable proceed to step 3 Arrange the hearth pieces in their proper position Carefully align the pilot holes and insert the hardware in the order shown in Fig 18 1 Hand tighten then use t
29. ngs Make sure to tighten every joint securely Do not use pipe joint compound to connect flare fittings Bring the gas supply pipe up from beneath the hearth or directly behind the hearth as appropriate for your installation CAUTION Installation and maintenance must be done by an NFI Certified or other qualified professional service technician Installer read these instructions and all other instructions provided with separately purchased product before installing Be sure you understand all safety precautions and warnings contained in the manual s Note An external on off valve in the gas line is optional for safety when the unit is not in use It also provides for convenient maintenance and repair INSTALLATION SAFETY GUIDELINES Installation and repair should be done by a qualified professional service technician The gas appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as necessary It is imperative that control compartment burners and circulating air passageways of the fireplace and or appliance are kept clean Carefully inspect for shipping damage If any parts are damaged call the dealer Correct installation and proper placement of the gas appliance and its decorative media is crucial to the safe performance of the appliance See the owner s manual provided with the gas appliance for further information DO NO
30. onal liner panel E exists and is to be Vented Phoenix w Back installed onto the top of the firebox through the top Venting fireplaces contain of the body piece a rear vent diverter panel for the top of the firebox Note The liners rest in place No hardware is required 2 Place the chimney mantel piece on top of the body piece no hardware required See Fig 21 3 Recessed Fireplaces Only Install Finish Substrate For recessed fireplace models install the finishing substrate as appropriate CONSULT APROFESSIONAL CONTRACTOR FOR YOUR INDIVIDUAL SETUP A Lf Fig 21 3 Place chimney mantel BURNER INSTALLATION BURNER INSTALLATION GUIDELINES This fireplace is designed to be installed with an R H P vented unvented gas appliance The gas appliance is purchased separately Follow all owner s manuals included with the appliance and decorative media to complete installation Note The gas appliance will come equipped with a flex connector Remove that connector and connect the existing fireplace flex connector to the appliance Make sure to tighten every joint securely LEAK TEST Turn on the gas supply and the key valve and test at all connections for leaks using a soapy water solution If bubbles appear a leak is present Turn off the gas and tighten at all connections Repeat until no leaks are present If a leak persists turn off the gas supply and contact the local gas company
31. onform with local codes and ordinances or in the absence of local codes with the latest National Fuel Gas Code ANSI Z223 1 Robert H Peterson Co 14724 East Proctor Avenue City of Industry CA 91746 REV 1 1411101350 1 L H2 011 f AMERICAN F RE DESIGNS INSTALLATION ET MODE D EMPLOI by RH Peterson co S rie montr ke ANSI Z21 97 CSA 2 41 pour l ext rieur des appareils gaz 7 lorsqu il est install avec 017 s lection R H P Ventil non ventil les appareils gaz Ventil S rie 015 017 073 818 868 Non Ventil S rie 115 117 173 118 168 Conforme PF NATIONAL Wo recommend that our gas INSTITUTE hearth products be installed 8 Nd and serviced by protes sionals who are certified in C US e the U S by the National F14 023 d coratifs CERTIFIED NFI Gas Specialists AVERTISSEMENT Pour l usage ext rieur seulement PHOENIX amp MARIPOSA CHEMIN ES D EXT RIEUR A AVERTISSEMENT Si l information en ce manuel n est pas suivie exactement une incendie ou une explosion peut r sulter entra nant des d gats mat riels le dommage corporel ou des pertes humaines Ne pas entreposer ni utiliser d essence ou d autres vapeurs et liquides inflammables proximit de cet appareil ou de tout autre Une bouteille de propane non branch e ne doit pas tre entrepos e proximit de cet ou tout autre appareil DANGER
32. our model may vary IDENTIFICATION PARTS LIST Phoenix 017 117 Mariposa 073 173 Description Hearth 16 Radiused Bullnose Hearth 16 Rectangle Bullnose Hearth 16 Roundover Hearth 4 Roundover Hearth assembly 113 Extended Bullnose Hearth assembly 137 Extended Bullnose Hearth assembly 160 Extended Bullnose Hearth assembly Corner Square Edge Firebox liners Vented 4 pc set Firebox liners Unvented 5 pc set Body Chimney Vented Chimney Unvented Hardware kits Body T Hardware kits Hearth t t 113 Extended Bullnose 137 Extended Bullnose 160 Extended Bullnose Corner Square Edge A e LL eee ee not shown T each kit contains 1 1 2 13 x 3 5 bolt 1 nut 2 washers t only required included with multi piece large hearths Phoenix Vented Fireplace w 16 Radiused Bullnose Hearth shown design of your model may slightly vary PARTS LIST cont Description E IDENTIFICATION PARTS LIST Hearth 16 Radiused Bullnose Phoenix w Back Venting 015 115 Hearth 16 Rectangle Bullnose Hearth 16 Roundover Hearth 4 Roundover Hearth assembly 113 Extended Bullnose Hearth assembly 137 Extended Bullnose Hearth assembly 160 Extended Bullnose Hearth assembly Corner Square Edge Firebox liners Vented 5 pc set Firebox liners
33. ranty covers defects in material and workmanship This warranty does not cover parts which become defective as a result of negligence misuse use not in compliance with the Owner s Manual Installation Instructions accidental damage improper handling improper storage improper installation lack of required routine maintenance as specified in the Owners Manual Installation Instructions electrical damage local gas impurities or failure to protect against combustibles Product must be installed and gas must be connected as specified in the Owners Manual Installation Instructions by a qualified professional installer Modifications to products which are not specifically authorized will void this warranty Accessories parts valves remotes etc when used must be Peterson products or this warranty is void Warrantied items will be repaired or replaced at Peterson s sole discretion This warranty does not apply to rust corrosion oxidation or discoloration unless the affected part becomes inoperable This warranty does not cover labor or labor related charges except as provided by separate specific written programs from the Peterson Co All repair work must be performed by a qualified professional service person and requires prior approval of Peterson Peterson may require the defective product or part to be returned to the factory to determine the cause of failure Peterson will pay freight charges if the product or part is determined to be defective
34. rner Square Edge Hearth Refer to drawing below See previous page for 2 Recess Option information Table 2 Hearth Dimensions 16 Rectangle Bullnose Hearth 16 Radiused Bullnose Hearth Select Models Shown your model may vary D Corner Square Edge Hearth SPECIFICATIONS AND DIMENSIONS cont This fireplace is designed to be installed with an R H P vented unvented gas appliance Below is a list of the options available for each fireplace type The gas appliance is purchased separately Contact your local American Fyre Designs dealer when ordering Fireplace Styles Vented Burner Options Unvented Burner Options Phoenix 017 G45 STAINLESS STEEL Phoenix w Back Venting 015 Log Set or Glass Models aa din 818 Match Lit Models up to 24 burners ariposa n Grand Mariposa 868 Valve Models up to 18 20 burners G22 STAINLESS STEEL Match Lit Models up to 24 burners Valve Models up to 18 burners Phoenix 117 G10 STAINLESS STEEL Phoenix w Back Venting 115 Grand Phoenix 118 Mariposa 173 Grand Mariposa 168 G21 STAINLESS STEEL up to 24 burners up to 24 30 burners with 24 log set Table 3 Fireplace Burner Options The unit s marking label plate is located in the interior of the firebox It hangs from a chain on the front inner wall valve side Ensure the plate is placed beh
35. se you should be able to solve the problem If the manual does not address your present problem or if you have other technical difficulties with your appliance please contact your local dealer or visit our web site at www rhpeterson com WARRANTY AMERICAN FYRE DESIGNS BY R H PETERSON CO LIMITED WARRANTY Robert H Peterson Co RHP warrants your American Fire Designs product to be free from defects in material and workmanship American Fyre Designs AFD exterior fireplaces BBQ islands fire tables fire urns fire pits Fire Falls Fire Walls gas logs and burner components products are warranted for THREE 3 YEARS All AFD valves electrical components and controls are warranted for ONE 1 YEAR excluding batteries This warranty does not apply to product damage caused by burning wood or any fuel other than natural gas or propane or damage or discoloration to product used in high wind conditions A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASE IS REQUIRED This warranty applies to the original purchaser for products which are installed in the United States or Canada and which are operated and maintained as intended for single family residential usage This warranty is valid only with proof of purchase shall commence on the date of purchase and shall terminate both as to original and any replacement products on the anniversary date of the original purchase of the product stated on the above schedules This war
36. served You must read all warnings and safety information and understand all of the information in this manual All installation requirements must be observed and met WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this unit may result in property damage or personal injury Confirm the installation site accommodates the fireplace per the requirements in this manual e Be sure the gas supply propane or natural is turned off at its source LOCATION While following all requirements and safety information in this manual see MINIMUM CLEARANCES TO COMBUSTIBLES section determine and prepare the location of the fireplace a hard and level surface Note For fireplaces a combustible surface is permitted Important For models with underneath gas installs the gas supply must be routed to the location the hearth will rest over at this stage ASSEMBLY REQUIRES TWO OR MORE PEOPLE EXERCISE EXTREME CARE DURING ASSEMBLY AND INSTALLATION FIREPLACE INSTALLATION cont FIREPLACE ASSEMBLY OVERVIEW CAUTION Fireplace components are heavy CAREFULLY handle all components during assembly Fig 17 1 provides an overall orientation and bolt assembly detail for the fireplace Phoenix w 16 Radiused Bullnose Hearth shown Phoenix w Back Venting Mariposa and Grand models assemble in a similar manner Assembly may slightly vary depending on mode
37. us injury may occur Children must be alerted to the hazard of high surface temperatures and should stay away to avoid burns or clothing ignition SERVICING AND CLEANING cont CONCRETE CARE As with any surface concrete components require regular maintenance and care Certain guidelines must be followed to preserve the concrete s appearance and structural integrity e Scratches may occur due to usage To minimize avoid striking or dragging heavy rough or sharp objects across the unit Spotting and hairline cracks may occur due to nature of product and are not considered a manufacturing defect Concrete products are porous and susceptible to discoloration from liquids especially oils and acidic substances During use clean up any spills immediately to prevent any possible staining or damage to the finish Avoid allowing water or any liquid substance to stand on the surface To clean the concrete first wash with a mild soap and water solution For stubborn stains a vinyl brush may be used Allow to dry Annually follow up with a masonry sealer in order to preserve the finish It should be noted that like natural stone concrete products will develop a patina when left outside No two concrete products are identically the same and the finish will vary TROUBLESHOOTING If you have trouble with your gas appliance please refer to the owner s manual provided with it By trying one or more of the solutions to the probable cau
38. wo 3 4 open end wrenches or equivalent to fasten Note The hearth pieces have access openings that allow for assembly 3 Place the body piece on top of the hearth Carefully align the pilot holes and insert the hardware in the order shown in Fig 18 2 Hand tighten then use two 3 4 open end wrenches or equivalent to fasten Hardware Bolts x 8 Fig 18 1 Assemble hearth if required Hardware Bolts x 4 Nuts x 4 ashers x 8 Fig 18 2 Assemble body FIREPLACE INSTALLATION cont Connect Gas Supply key valve Important Before installation be sure the gas supply location propane or natural is turned off at its source may vary Important Locate the gas supply line out of pathways Connect where people may trip over it or in areas here where the line may way be subject to accidental damage if applicable The fireplace has a key valve pre installed on either the right or left side of the fireplace For fireplaces that have the rear gas line option a 1 2 rigid gas pipe is pre installed to the valve and protrudes out of the rear of the unit A flex connector is pre attached to the key valve on the interior of the fireplace An R H P burner is to be connected to it at a later time Fig 19 1 Route gas supply rear install 1 Route the gas supply natural gas household propane or from an L P Cylinder to the unit