1. NPC 3 NPC 3 NOZZLE MIX TYPE PILOT BURNER Safety design in which temperature on the external surface of the Durner body is kept low with stable combustion by employment of a unigue combustion system The simple nozzle structure is easy to mount remove and maintain in addition a flame detector can be installed at the rear of the burner and flame is reliably monitored because it is Specifications Structured so as to allow combustion air to flo
2. 2 0 5kPa 20kPa BP 2B H 3 4 Note 1 When mounting the flame detector separately use the flame detector separately sold and pipe with flame detector separately sold In addition because model BP 1B cannot be equipped with the flame detector on the burner mount the flame detector to the burner front plate etc of the main burner 2 If the furnace pressure IS high 0 5kPa to 20kPa use BP 2B H 3 When using with special fuel gas contact us 4 Items marked with are flow rates in a standard state APE APE ELECTRIC IGNITION TYPE PILOT BURNER This is a pilot burner for main burner ignition of a large capacity to be mounted On an air resistor etc And this is an electric ignition type pilo
3. Naooya Sales Office 1 21 19 Meieki Minami Nakamura ku Nagoya 450 0003 Japan TEL 052 561 3561 FAX 052 561 3566 Tel 81 52 561 3561 Fax 81 52 561 3566 582 0027 1000 6 Combustion Laboratoy 1000 6 Enmyo cho Kashiwara Osaka 582 0027 Japan TEL 072 977 8503 FAX 072 978 6981 Tel 81 72 977 8503 Fax 81 72 978 6981 140205 M The descriptions and specifications are subject to change without notice
4. 1 Note 1 When the flame detector is mounted a sight hole is not attached Separately use the flame detector separately sold and pipe with flame 2 0 5kPa 20kPa MPN 2 H detector separately sold 2 lf the furnace pressure is high 0 5kPa to 20kPa use model MPN 2 H 3 3 When using with special fuel gas contact us RP 15K RP 15K PILOT BURNER This allows for easy maintenance and also for visual flame monitoring by built in sight hole in addition to the flame detector Specifications Combustion capacity Gas supply pressure Air SUDDIy pressure Air flow rate Mounting hole for spark plug Air inlet Rc34 Gas
5. a burner in combination with a Venturi mixer and flame retention tip and also a torch burner for main burner manual ignitlion and roast neatin9 Specifications Model A AL 422 428 A AL 422 428 Combustion capacity KW 120kKW 4 6kW 120kW esswpipesr 3KPa 15KPa o 13A Fuel 2 Butane air gas Butane Propane 13A town gas Standard accessories Gas valve Dimensions Combustion capacity kW Gas connection pipe diameter RC 1 4 RC3 8 APS Note The nozzle part uses the model APS pilot burner nozzle gt ed Gas connection pipe Venturi mixer Flame retention tip Gas cock A 90 AL Note There is an A type of a straight type and an AL type of a 90 degrees neck bend Dimensions 220 ChugaiKo NN The equipments in this catalog include patented patent pendi
6. he main burner or the burner front plate etc 2 Install the air pipe on the air resistor part to supply combustion air 3 When using with special fuel gas contact us ALT ALT LIGHTING TORCH Specifications Model ALT N ALT A 4kW2 8kW 1 4kW 2 8kW Combustion capacity This is a manual ignition lighting torch for the main Durner and pilot burner Hose band APS 5m APSnozzle Rs Standard length of rubber hose 5m Gas valve Gas inlet RC1 4 Hose band Gas supply pressure lt kPa LPG 13A COG Fuel LPG 19Atown gas Butane ar gas COG 5m Standard accessories Gas valve Rubber hose 5 m Hose band 1 5kPa A AL A AL TORCH BURNER This is
7. hole is not attached Separately use the flame detector separately sold and pipe with flame 2 NP 1 5 1 75kW detector separately sold 2 For small capacity model NP 1 5 combustion capacity 1 75kW pilot 3 burner is also avalilable 3 When using with special fuel gas contact us MPN 2 MPN 2 NOZZLE MIX TYPE PILOT BURNER This is also available for high furnace
8. inlet Rc1 2 MK UE Se R ea U V g U V MM AUD300C Built in sight hole Ultra vision AUD300C option HSGB 2 HSGB 2 PILOT BURNER UV UV flame rod can be selected for flame detection Specifications Combustion capacity Gas supply Dressure Air supply presSure 2 3kPa Air flow rate 25m h normal Fuel Gas fuel in general Air inlet Rc116 Air inlet Rc112 1 Mounting hole for sight hole G1 2 Mounting hole for spark plug G1 2 Gas inlet Rc3 8 Gas inlet Rc3 8 Mounting hole for flame eye and flame rod G1 2 BP BP BROTHER PILOT BURNER Specifications BP 1B BP 2B Combustion capacity 9kW 23kW sppy pres Gas supply pressure 7 7m h 22m h Town Oil gas Industrial Air supply pressure Air f
9. low rate Fuel 2 This is an electric ignition type pilot burner which was designed in consideration of a longer life of the ignition plug and iS maintenance free The gas piping IS classified into two systems of main and assist systems and the assist gas extinguishes after ignition by the ignition plug then the burner burns only with the main gas The ignition plug is cooled by air during operation and does not reach a high temperature therefore it has a long service life and is maintenance free BP 1 Ignition plug EE separately sold Al Ir j RC3 4 Assist gas 92 a Air limiting orifice TT fT Air SN gas Main gas Main gas RC3 8 Gas limiti
10. ng orifice BP 2 Gas limiting orifice Air assist gas Air limiting orifice Main gasJL RC1 2 a Main gas Arr RC1 7RC9 6 Sight hole lgnition plug separately sold Flame monitor mounting hole 1 1 BP 2B Standard accessories Gas valve 1 piece respectively for main and assist Air valve Sight hole Gas regulating cock 1 piece respectively for main and assist Sight hole BP 2B only Gas limiting orifice Air limiting orifice 1 BP 1B
11. ng technologies SI This catalog uses the Sl units which can be calculated from the following formula 1kcal h 1 163X10 kW 1kW 860kcal h 1kcal 4 18kJ 10000kcal 41 8MJ 1kJ 0 239kcal 1MJ 239kcal 1mmH O 1kg m 9 81Pa 1kg cm 98 1kPa 1Pa 0 102mmHzO 1kPa 102mmHzO SAFETY PRECAUTIONS Read the instruction manual carefully before using the eduipment MA lt Ke A 1 URL http www chugai cO jD 592 8331 2 4 Sakai Works 2 4 Chikko Shinmachi Nishi ku Sakai 592 8331 Japan TEL 072 247 1440 FAX 072 247 1441 Tel 81 72 247 1440 Fax 81 72 247 1441 108 0075 2 5 7 Tokyo Branch 2 5 7 Konan Minato ku Tokyo 108 0075 Japan TEL 03 5783 3378 FAX 03 5783 3368 Tel 81 3 5783 3378 Fax 81 3 5783 3368 450 0003 1 21 19
12. pressure since this iS for main burner ignition of a large Capacity and is of a flange mounting type A flame detector is mounted at the rear of the burner and flame is reliably monitored since it is structured so as to allow combustion air to flow through the center of the burner Furthermore purge air for the flame detector is also unnecessary and the burner can be reliably ignited by electric ignition with an ignition plug at low cost Since the ignition plug is in the low temperature part it does not reach a high temperature and has no trouble such as burning and di Specifications adherence of carbon Model MPN 2 Combustion capacity 23kW lgnition plug separately 0 Sauppy pe Gas supply pressure lt 6kPa A Air supply pressure 3 8kPa Air flow rate 23m h normal NN ll gas Industrial gt RY gt w gn fn 2 1 NE Cas ImIHng orfice MPN 2D MPN 2 H OO 1 TT 1 Gas RC1 2 MPN 2D MPN 2 H Standard accessories Gas cock Air cock Sight hole standard type high furnace Gas limiting orifice Air limiting Orifice pressure type Air limiting orifice
13. t Durner in which only fuel gas is Supplied from the pilot burner and is reliably ignited by the ignition plug built in the gas nozzle part then stable comDustion is performed Burner support Ignition plug Combustion air inlet Gas inlet RC1 2 High voltage lead wire le Mounting flange Specifications APE FP 20 APE FP 50 23kW 58kW Combustion capacit 3kPa Town gas Oil gas Industrial gas Gaypesse 3KPa 3kPa Gas SUDDI pressure 3kPa Fuel Standard accessories Gas valve Burner support Ignition plug High voltage lead wire lgnition transformer 1 2 3 Note 1 The flame detector cannot be mounted on the burner Mount it to the air resistor of t
14. w through the center of the burner ES Furthermore Durge air for the flame detector is also unnecessary and the burner can be reliably ignited by electric ignition with an ignition plug at low cost Since the ignition plug 3 5kW is located in the air and gas mixing part where there is no combustion flame it does Combustion capacit not reach a high temperature and has no trouble such as burning and adherence of 2 8kPa carbon a 1 Gas SUDDIy pressure Ai eo Air supply pressure lt 8kPa RC3 8 AiniWng odee Air Air limiting orifice BE 3 3m h normal Air flow rate lgnition plug Sight hole Fuel Town gas Oil gas Industrial i a G RC1 4 Standard accessories Eo Gas cock Air Cock Sight hole Gas limiting orifice 0 i 2 Air limiting orifice lgnition plug and cap 1 Note 1 When the flame detector is mounted a sight
Download Pdf Manuals
Related Search
Related Contents
Manual de Usuario 50ZP (Español) Murakami Data Communicator for Electronic Table Balance MDC 広報きほく 2009年4月号 全ページ VRAE: User Manual - Eco Environmental Copyright © 1999 Iomega Corporation Alle Rechte vorbehalten. Die Inst Sheet OLW14 RevG_0812.pmd Betriebsanleitung FST CDE-T Ableiter Proel CHLP170LU15 Samsung 730MW Manuel de l'utilisateur Copyright © All rights reserved.