Home

取扱説明書 INSTRUCTION MANUAL - KYOCERA Connector Products

image

Contents

1. FPC Basically connectors shall be mounted by the mounting machine In case of the manual mounting do not to touch contact tails It is the structure of this product that contacts move with the movement of the actuator If the connector is heated when the actuator is closed therefore the contact will be deformed Consequently the actuator is should be opened when connector is in the reflow oven or when it is hand soldered After they are mounted it should be avoided to move the actuator without an FPC inserted SERIES 6800 INSTRUCTION MANUAL SPEC No 205 03 288 106 03 004 PAGE 3 8 KYOCERA Connector Products Corporation 32 FPC INSERTION AND EXTRACTION OF FPC 1 FPC FPC Insert FPC vertically as shown below Insert the FPC and push it until it hits the card slot of connector O mM m lo FPC Insert the FPC vertically until it hits to th
2. 6800 Series 6800 connector is a one touch locking type dual contact type connector with 0 5mm pitch and 1 2mm height Care should be taken when handling this connector This manual describes cautions in handling series 6800 2 NAME OF EACH PART lt gt lt The actuator is open factory opened gt INSULATOR CONTACT SERIES 6800 INSTRUCTION MANUAL SPEC No 205 03 288 106 03 004 PAGE 2 8 KYOCERA Connector Products Corporation 3 HANDLING NOTES 3 1 MOUNTING ON THE BOARD
3. Store connectors under normal temperature normal humidity and no dust condition When storing connectors out of the embossed tape pressure shall not be applied to contact tails SERIES 6800 INSTRUCTION MANUAL SPEC No 205 03 288 106 03 004 PAGE 8 8
4. FPC Pay attention not to apply an excess load to the connector contacts because of the flexion of FPC Please contact us when an FPC has to be bent repeatedly near the card insertion opening We will conduct evaluation tests according to conditions FPC As long as possible connector SERIES 6800 INSTRUCTION MANUAL SPEC No 205 03 288 106 03 004 PAGE 7 8 KYOCERA Connector Products Corporation 4 OTHER NOTES 4 1 FOR FLUX WICKING
5. When a printed circuit board with the preflux applied is used or the amount of solder gets increased flux wicking occurs in a core hole of the insulator and the wicked flux becomes solidified to fix the contact which could affect the spring movement of contacts If a printed circuit board with the preflux applied is used or the amount of solder gets increased therefore please consult us Evaluative verifications may be conducted by us depending on conditions Insulator Solidifying flux Core hole Contact Movable direction of contacting 4 2 FOR HANDLING PRODUCTS PACAGED IN TAPE amp REEL Throwing and large shock shall not be permitted However though contact tails are protected in the embossed tape when delivered 5 STORAGE AND CONTROL
6. DIV 04 SPEC NUMBER 205 03 288 W KYOCERA KYOCERA Connector Products Corporation INSTRUCTION MANUAL SERIES 6800 0 5mm PITCH FPC CONNECTOR e po wa We ym o eonan Wis smmws Neewwa YE lk EDW DCN DATE PREPARED CHECK APPROVED 106 03 003 KYOCERA Connector Products Corporation H X TABLE OF CONTENTS 1 OUTLNE SS 2 p 28 A CNAME OF FACH PART WI 2 3 PRECAUTIONS IN HANDLING ennnnnnnnnnennnnnnnnnnnnntnnnntnnnntnnntnnntnnntennttten teen tte stent teet ttes 3 31 MOUNTING ON THE BOARD SKIN 3 32 FPCA OOC INSERTION OF FPO SN 34 Sa FPEO rto vc PELUNCG OUT Re 5 3A FPO RE FEON OF EB NN 6 4 OTHER CAUTIONS srono amoge a a a aR 7 41 ROWXWIOMNGROEOOOO RI NN N WT NN OO5KOWO ated 7 42 FOR HANDLING PRODUCTS PACAGED IN TAPE amp REEL seee 7 5 STORAGE MANAGEMENT ee 7 SERIES 6800 INSTRUCTION MANUAL SPEC No 205 03 288 106 03 004 PAGE 1 8 KYOCERA ConnectorProducts Corporation 1 OUTLINE 6800 0 5mm 1 2mm FPC
7. L SPEC No 205 03 288 106 03 004 PAGE 5 8 KYOCERA Connector Products Corporation 33 FPC FPC EXTRACTION Raise the actuator to open as shown below O Bondi lo 90 Actuator opening angle must be 90 degrees at maximum and any further load shall not be applied in the opening direction SERIES 6800 INSTRUCTION MANUAL SPEC No 205 03 288 106 03 004 PAGE 6 8 KYOCERA Connector Products Corporation When opening the actuator push the center of the actuator directly upward with the actuator evenly loaded on it s right and left around the center Do not apply uneven load on the actuator when opening it Raise the actuator straight upward 3 4 FPC FLEXION OF FPC FPC
8. e slot end F 7 7 4 7 X X 1 A OW oK NG NG SERIES 6800 INSTRUCTION MANUAL SPEC No 205 03 288 106 03 004 PAGE 4 8 KYOCERA ConnectorProducts Corporation 2 FPC lt Make sure that the FPC is not inserted obliquely and close the actuator with a soft pressure applied on it in the direction of the rotation axis DD 3 below If the actuator is not closed completely due to a warpage of its own run your finger across the actuator and make sure that it is closed and locked below When closing the actuator apply the force on the center of the actuator as shown below so that the Stress could be applied evenly laterally Do not apply the force to the side end SERIES 6800 INSTRUCTION MANUA