Contents

1. Operating environ ment Storage environ ment Altitude Power 3 digit 17 mm large LCD maximum reading 4000 with function and units sign annunciators 3 digit 4000 counts 17 mm LCD display and function units sign annunicators 3 digits 15 mm large LCD maximum reading 4000 with function and units sign annunciators 42 segment analogue bar graph Automatic positive implied negative indicated OL is displayed Battery symbol is displayed when the battery voltage drops below accurate operating level P 1625 2 Sec nominal and 20 sec analog display P 1610 P 1615 2 0 x per second nominal P 1610 30 minutes P 1615 35 minutes P 1625 20 minutes 10 C 50 C 14 F 122 F 0 85 RH 30 C 60 C 22 F 140 F 0 85 R H with battery removed from meter 3000 m Standard 9 V battery 24 Jaw opening Capability 30 mm conductor Size 229 H x 80 W x 40 D mm Weight 4 1 DC Volts Model Ranges Resolution Accuracy P 1610 400mV 100uV 0 8 rdg 3 dgt 4V 1mV 40V 10mV 1 5 rdg 3 dgt 400V 100mV 600V 1V 2 0 rdg 3 dgt P 1615 400mV 100uV 0 8 rdg 3 dgt 4V 1mV 40V 10mV 1 5 rdg 3 dgt 400V 100mV 600V 1V 2 0 rdg 3 dgt P 1625 400mV 100uV 0 8 rdg 2 dgt 4V 1mV 40V 10mV 1 5 rdg 2 dgt 400V 100mV 600V 1V 2 0 rdg 2 dgt Overload protection 600V AC DC 25 ZERO Tast
2. rfen nicht berschritten werden Falls nicht zweifelsfrei ausgeschlossen werden kann dass diese Spannungsspitzen durch den Einfluss von transienten St rungen oder aus anderen Gr nden berschritten werden muss die Messspannung entsprechend 10 1 vorged mpft werden Nehmen Sie das Ger t nie in Betrieb wenn es nicht v llig geschlossen ist Bei der Widerstandsmessungen keine Spannungen anlegen 1 2 Plug the black and red test leads into the COM and Hz input terminals respectively 3 Determine that the amplitude level of the signal to be measured is not greater than the input voltage limit 250 V AC DC The signal amplitude must also be greater than the sensitivity level 4 Attach the probe tips to the points across which the frequency is to be measured and read the result directly from the display 5 Disconnect the DCM test leads 6 8 Temperature measurements 1 Set the function switch to C F or TEMP position The meter automatically defaults to C range 2 Insert the meter s white temperature adaptor into the V Q input terminal and the COM terminal Ensure that the minus marking at the adaptor is inserted into the COM terminal and the plus marking is inserted into the V Q input terminal 3 Connect the K type probe into the meter adaptor and measure the temperature of the apparatus or area required 4 Read the temperature directly from the display 5 To change the measuring unit from C to F
3. P 1615 Funktionsbereichwahlschalter in Stellung V Hz drehen und mit der Taste Hz die Frequenzmessfunktion ausw hlen P 1625 Funktionsbereichwahlschalter in Stellung V Hz drehen und die Mode Taste gt 2 Sekunden gedr ckt halten um die Frequenz messfunktion ausw hlen 2 Schwarze Pr fleitung an den COM Eingang und rote Pr fleitung an den V Q Hz Eingang anschlie en w Messspitzen der Pr fleitungen ber das entsprechende Bauteil bzw die entsprechende Schaltung anschlie en 4 Frequenz in der LCD Anzeige des Zangenmessger tes ablesen 5 Nach beendeter Messung Pr fleitungen von der Messschaltung und den Eing ngen des Messger tes abziehen 6 8 Temperaturmessungen Zur Messung von Temperaturen wie beschrieben verfahren 1 Funktionswahlschalter in Stellung C F bzw TEMP drehen Adapter f r Thermokopplungsmesssonde in die V Q Buchse und die COM Buchse entsprechend der Plungsmarkierung auf dem Adaptereinstecken N Typ K Thermokopplungsmesssonde an den Adapter anschlie en 3 Mit der Messsonde die Temperatur des gew nschten Objektes messen und Temperaturwert in der LCD Anzeige ablesen 4 P 1610 P 1625 Mit der MODE Taste zwischen C und F w hlen 7 Auswechseln der Batterie Bei Aufleuchten des Batteriesymbols ist die Batterie verbraucht und muss baldm glichst ersetzt werden Zum Auswechseln der Batterie wie beschrieben verfahren 19 1 Zangenmessger t ausschalten un
4. Rotary function switch 9 Zero button 10 P 1615 Range select button P 1625 Backlight 11 VQ jack COM Terminal This is the negative ground input for all measurement modes except current Connection is made to it using the black test leads V Hz F Q Input Terminal This is the positive input terminal for voltage capacitance frequency ohms and diode measurements Connection is made to it using the red test lead Display The display indicates the measured value of a signal function mode and annunciator Function Range selector rotary switch This rotary switch selects the function and selects the desired range Range Button Press RANGE button to select the manual range mode and Turn off the AUTO annunciator The meter remains in the range it was in when manual reading was selected In the manual range mode each time you press RANGE button the range and the input range annunciator increments and a new value is press and hold down RANGE button for 2 seconds The AUTO annunciator turns back on 32 Hold Button Press HOLD button to toggle in and out of the Data Hold mode In the Data Hold mode the HOLD annunciator is displayed and the last reading is frozen on the display Press the HOLD button again to exit and resume readings Zero Button P 1625 Press ZERO button to enter the relative mode the ZERO A annunciator turns on zero the display and store the displayed reading as a refer
5. damage to the equipment under test Before measuring current make certain that the test leads are removed from the instrument The snap around is overload protected up to 600 V AC for up to 1 Min Do not take current readings on circuits where the maximum current potential is not known Do not exceed the maximum current that this instrument is designed to measure 1 Set Function Switch to 40 A 400 A or 1000A AC or 40A 400A or 1000A DC P 1615 P 1625 2 Press the trigger to open the transformer jaws and clamp them around a conductor Jaws should be completely closed before taking a reading 3 The most accurate reading will be obtained by keeping the conductor across centre of the transformer jaws 4 The reading will be indicated on the display 5 Reduce the range setting if too high until a satisfactory best resolution reading it obtained 6 3 Resistance measurements WARNING Attempting resistance or continuity measurements on live circuits can cause electric shock damage to the instrument and damage to the equipment under test Resistance measurements must be made on de energized DEAD circuits only for maximum personal safety The electronic overload protection installed in this instrument will reduce the possibility of damage to the instrument bus not neces sarily avoid all damage or shock hazard 35 3 Technische Daten Anzeige P 1610 3 stellige 17 mm LCD Anzeige mit einer max Anzeige von 4000 und Anzei
6. des Bedieners f hren Vor dem ffnen der Zange zur Aufnahme des zu messenden Stromleiters alle Pr fleitungen von den Eing ngen des Zangenmessger tes abziehen Die Transformatorzange ist bis max 600 V max f r 1 Minute gegen berlast gesch tzt Keine unbekannten Stromgr en messen Maximal zul ssigen Messstrom auf keinen Fall berschreiten 1 Abh ngig von der gew nschten Messfunktion Funktions Bereichs Wahlschalter in Stellung 40 A 400A bzw 1000A AC oder 40A 400A bzw 1000A DC P 1615 P 1625 drehen 2 Zange mit dem Zangen ffner ffnen und zu messenden Leiter in die Zange nehmen Zange durch Loslassen des Zangen ffners schlie en Darauf achten dass die Zange vollst ndig schlie t 3 Messwert in der LCD Anzeige des Zangenmessger tes ablesen F r genaue Messergebnisse sollte darauf geachtet werden dass sich der Leiter mittig in der Zange befindet und der entsprechende Messbereich gew hlt ist 4 Nach erfolgter Messung Zange ffnen und vom Leiter entfernen 6 3 Widerstandsmessungen ACHTUNG Widerstandsmessungen oder Durchgangspr fungen an spannungs f hrenden Bauteilen oder Schaltungen k nnen zur Besch digung des Zangenmessger tes des Bauteiles bzw der Schaltung und oder Ver letzungen des Messpersonals f hren 15 3 Specifications Display P 1610 P 1615 P 1625 Polarity indication Overrange Indication Low battery Indication Display update Rate Auto Power off
7. v M 10 dgt 4mF 1uF 4 5 v M 10 dgt 40mF 10uF 5 0 v M 10 dgt berlastschutz 250 V AC DC 4 7 Frequenzmessungen Modell Bereich Aufl sung Genauigkeit Empfindlichkeit P 1610 5Hz 1mHz 1 5 v M 5 dgt 50 Hz 10mHz 500 Hz 100mHz 5 kHz 1Hz 1 2 v M 2 dgt 10 Ver min 50 kHz_ 10 Hz 500 kHz 100 Hz 5 MHz_ 1 kHz 1 5 v M 10dgt 10 MHz 10kHz P 1615 5Hz 1mHz 1 5 v M 5 dgt 50 Hz 10mHz 500 Hz 100mHz 5 kHz 1Hz 1 2 v M 2 dgt 10 Ver min 50kHz 10 Hz 100 kHz 100 Hz P 1625 4 kHz 1Hz 1 5 v M 2 dgt 5 Ver min berlastschutz 250 V AC DC 8 4 5 Widerstandsmessungen Modell Bereich Aufl sung Genauigkeit P1610 4000 100 mQ 1 0 v M 4 dgt 4kQ 19 40 KQ 1002 1 5 v M 2 dgt 400 kn 100 Q 4MQ 1kQ 2 5 v M 3 dgt 40 MQ 10 kQ 3 5 v M 5 dgt P1615 4000 100 mQ 1 0 v M 4 dgt 4kQ 10 40 KQ 1009 1 5 v M 2 dgt 400 kn 100 Q 4 MQ 1kQ 2 5 v M 3 dgt 40 MQ 10 kQ 3 5 v M 5 dgt P1625 4000 100 mQ 1 0 v M 4 dgt 4kQ 10 40 kQ 109 1 5 v M 2 dgt 400 kn 100 Q 4 MQ 1kQ 2 5 v M 5 dgt 40 MQ 10 kQ 3 5 v M 10 dot Uberlastschutz 250 V AC DC 7 1 Current Clamp 2 Clamp trigger 3 P 1615 Data Hold Backlight P 1625 Data Hold 4 Mode select button 5 P 1615 Hz button P 1625 Peak Hold button 6 LCD Display 7 COM Input jack 8
8. 0 rdg 20 dgt 400nF 100pF 4uF 1nF 3 0 rdg 5 dgt 40uF 10nF 400uF 100nF 4 0 rdg 10 dgt 4mF 1uF 4 5 rdg 10 dgt 40mF 10uF 5 0 rdg 10 dgt Overload protection 250 V AC DC 4 7 Frequency Model Range Resolution Accuracy Sensitivity P 1610 5Hz 1mHz 1 5 rdg 5 dgt 50 Hz 10mHz 500 Hz 100mHz 5 kHz 1 Hz 1 2 rdg 2 dgt 10 Vims min 50 kHz_ 10 Hz 500 kHz 100 Hz 5 MHz _ 1 kHz 1 5 rdg 10dgt 10 MHz 10kHz P1615 5Hz 1mHz 1 5 rdg 5 dgt 50 Hz 10mHz 500 Hz 100mHz 5 kHz 1Hz 1 2 rdg 2 dgt 10 Vims min 50 kHz_ 10 Hz 100 kHz 100 Hz P 1625 4kHz 1Hz 1 5 rdg 2 dgt 5 Vims min berlastschutz 250 V AC DC 28 4 8 Duty cycle Model Range Resolution Accuracy P 1610 0 5 99 0 0 1 1 2 rdg 2 dgt Pulse width 100 us 100 ms P 1615 0 5 99 0 0 1 1 2 rdg 2 dgt Pulse width 100 uS 100 ms Frequency 5 Hz 100 kHz Overload protection 250 V AC DC 4 9 Temperature Model Range Resolution Accuracy P1610 50 400 C 0 1 C 3 0 rdg 5 dgt 400 1000 C 1 C 58 400 F 0 1 F 3 0 rdg 7 dgt 400 1832 F 1 F P 1615 20 1000 C 1 C 3 0 rdg 5 dgt 4 1832 F 1 F 3 0 rdg 7 dgt P1625 40 1000 C 1 C 2 5 rdg 3 dgt 40 1832 F 1 F 2 5 rdg 5 dgt Overload protection 60 V DC 24 V AC 4 10 Conti
9. 2 5 v M 5 dgt berlastschutz 60 V DC 24 V AC 4 10 Durchgangspr fung Modell Tonsignal Grenzwert Teststrom P 1610 lt 1000 P 1615 lt 1009 lt 1mA P 1625 lt 350 Uberlastschutz 250 V AC DC 4 11 Diodentest Modell Teststrom Spannung bei offener Last P 1610 P 1615 0 3 mA 1 5V P 1625 Uberlastschutz 250 V AC DC 9 5 Instrument Layout 1 3 5 7 Verena wa T 8 9 Abb 5 1 Front and backview of P 1610 Current Clamp Data Hold Backlight LCD Display Rotary function switch 9 Hz duty button 11 Battery cover 2 4 6 8 10 30 Clamp trigger Mode select button COM Input jack Range select button VOQ C F jack Abb 5 2 Frontview of P 1615 and P 1625 31 4 6 Kapazit tsmessungen Modell Bereich Aufl sung Genauigkeit P 1610 40nF 10pF 5 0 v M 100 dgt 400nF 100pF 3 0 v M 5 dgt 4uF 1nF 3 5 v M 5 dgt 40uF 10nF 100uF 100nF 5 0 v M 5 dgt P1615 40nF 10pF 5 0 v M 100 dgt 400nF 100pF 3 0 v M 5 dgt 4uF 1nF 3 5 v M 5 dgt 40uF 10nF 100uF 100nF 5 0 v M 5 dgt P 1625 4nF 1pF 5 0 v M 30 dgt 40nF 10pF 5 0 v M 20 dgt 400nF 100pF 4uF 1nF 3 0 v M 5 dgt 40uF 10nF 400uF 100nF 4 0
10. Gefahr der Besch digung des Ger tes Ein maximaler Spannungsunterschied von 600 V zwischen dem COM Eingang und Erde darf nicht berschritten werden 14 Zur R ckkehr zu automatischer Bereichswahl RANGE Taste f r mindestens 2 Sek gedr ckt halten Das Umschalten auf automatische Bereichswahl wird durch Aufleuchten des Funktionssymbols AUTO angezeigt HOLD Taste Zur Aktivierung bzw Aufhebung der Messwert Haltfunktion Beim Dr cken der HOLD Taste wird der Messwert in der LCD Anzeige eingefroren und das Funktionssymbol HOLD leuchtet auf Zum Verlassen der HOLD Funktion Taste HOLD erneut dr cken ZERO Taste P 1625 F r Relativwertmessungen Zur Speicherung des angezeigten Messwertes als Referenzwert Bei Relativwertmessungen entspricht der angezeigte Messwert immer dem Differenzwert zwischen dem gespeicherten und dem gemessenen Signal Bei einem gespeicherten Referenzwert von 24 V z B und einem aktuellen Messwert von 12 5 V w rde in der LCD Anzeige die Messwertanzeige 11 50 V erscheinen Ist der gemessene Wert mit dem gespeicherten Referenzwert identisch zeigt die LCD Anzeige den Wert 0 Die Taste dient gleichzeitig der Nulleinstellung bei DC Messungen Transformatorzange Zur Messung von Gleich und Wechselstr men Die Plusmarkierung identifiziert die Flussrichtung des Gleichstromes durch den in der Zange befindlichen Leiter Der angezeigt Messwert ist positiv PEAK Taste P 1625 Zur Messung des Spitzenwer
11. citance range Plug the black and red test leads into the COM and V Q input terminals respectively Touch the probes to the capacitor Always observe polarity makings when measuring pobrized capacitors Read capacitance value directly from the display After completing the measurement disconnect the DCM test leads 6 7 Frequency measurements 1 P 1610 Set the rotary selector switch to the Hz position P 1615 Set the function switch to V Hz position and select Hz or duty with the Hz button P 1625 Set the function switch to V Hz position and press the MODE button for gt 2 seconds to select the frequency range Vor dem Umschalten auf eine andere Messfunktion Pr fleitungen oder Tastkopf von der Messschaltung abkoppeln Keine Strommessungen im Spannungsbereich V Q vornehmen Ger t Pr fleitungen und sonstiges Zubeh r vor Inbetriebnahme auf eventuelle Sch den bzw blanke oder geknickte Kabel und Dr hte berpr fen Im Zweifelsfalle keine Messungen vornehmen Messarbeiten nur in trockener Kleidung und vorzugsweise in Gummischuhen bzw auf einer Isoliermatte durchf hren Messspitzen der Pr fleitungen nicht ber hren Warnhinweise am Ger t unbedingt beachten Bei unbekannten Messgr en vor der Messung auf den h chsten Messbereich umschalten Ger t keinen extremen Temperaturen direkter Sonnen einstrahlung extremer Luftfeuchtigkeit oder N sse aussetzen Starke Ersch tterung vermeiden Ger t nicht in de
12. ck test lead into the COM input jack on the meter and connect the test lead tip to a grounded point the reference point for measurement of voltage 3 Select the desired AC voltage range or DC voltage range If the magnitude of the voltage to be measured is unknown always start with the highest range WARNING To avoid possible electric shock instrument damage and or equipment damage do not attempt to take any voltage measurements if the voltage is above 600 V AC DC are the maximum voltages that this instrument is designed to measure The COM terminal potential should not exceed 600 V measured to ground 4 Plug the red test lead into the V Q Input jack on the meter and connect the circuit where a voltage measurement is required Voltage is always measured in parallel across a test point 5 Turn on power the circuit device to be measured and make the voltage measurement reduce the range setting if set too high until a satisfactory reading is obtained 6 After completing the measurement turn off power to the circuit device under test discharge all capacitors and disconnect the meter test leads 34 6 2 Current Measurements WARNING These Snap arounds are designed to take current measurements on circuits with a maximum voltage difference of 600 V AC between any conductor and ground potential Using the snap around for current measurements on circuits above this voltage may cause electric shock instrument damage and or
13. d alle Pr fleitungen von den Eing ngen des Ger tes und der Messschaltung abziehen 2 Schraube im Batteriefachdeckel mit einem Schraubendreher l sen und Batteriefachdeckel abnehmen 3 Batterie aus dem Batteriefach entnehmen u durch eine neue 9V Blockbatterie NEDA 1604 oder gleichwertige Batterie ersetzen 4 Batteriefachdeckel wieder auflegen und mit Schraube sichern ACHTUNG Verbrauchte Batterie ordnungsgem entsorgen Verbrauchte Batterien sind Sonderm ll und m ssen in die daf r vorgesehenen Sammelbeh lter gegeben werden Nehmen Sie das Ger t nie in Betrieb wenn es nicht v llig geschlossen ist 8 Wartung Die Abnahme der r ckseitigen Geh useh lfte sowie Wartungs und Reparaturarbeiten am Ger t d rfen nur von qualifizierten Fachkr ften vorgenommen werden Zur Reinigung des Geh uses nur ein weiches trockenes Tuch ver wenden Geh use niemals mit L sungsmitteln oder scheuerstoff haltigen Reinigungsmitteln reinigen Alle Rechte auch die der bersetzung des Nachdruckes und der Vervielf ltigung dieser Anleitung oder Teilen daraus vorbehalten Reproduktionen jeder Art Fotokopie Mikrofilm oder ein anderes Verfahren nur mit schriftlicher Genehmigung des Herausgebers gestattet Letzter Stand bei Drucklegung Technische nderungen des Ger tes welche dem Fortschritt dienen vorbehalten Hiermit best tigen wir dass das Ger t die in unseren Unterlagen genannten Spezifikationen erf llt und werkse
14. des Kondensators anlegen 4 F r genaue Messergebnisse vor der Messung Nullabgleich durch Dr cken der ZERO Taste durchf hren P 1615 P 1625 5 Kapazit tswert in der LCD Anzeige ablesen Hinweis Mit Restspannung behaftete Kondensatoren und Kondensatoren mit schlechtem Isolationswiderstand k nnen das Messergebnis negativ beeintr chtigen 6 Nach beendeter Messung Pr fleitungen vom Kondensator und den Eing ngen des Messger tes abziehen 6 7 Frequenzmessungen Zur Messung wie beschrieben verfahren 1 P 1610 Funktions Bereichswahlschalter in Stellung Hz drehen 18 6 4 Durchgangspr ffunktion ACHTUNG Messungen nur an spannungsfreien Schaltungen bzw Bauteilen vornehmen Zur Messung der Durchg ngigkeit von Bauteilen wie beschrieben verfahren 1 Funktions Bereichwahlschalter in Stellung drehen Schwarze Pr fleitung an den COM Eingang und rote Pr fleitung an den V Q Eingang anschlie en Pr fleitungen ber das zu messende Bauteil anlegen vorher sicherstellen dass Bauteil spannungslos ist Bei Widerst nden unter 35 Q P 1625 bzw 100 Q P 1610 P 1615 Bauteil durchg ngig ert nt ein Summton Nach Beendigung der Messung Pr fleitungen vom Bauteil und den Eing ngen des Zangenmessger tes abziehen 6 5 Diodentest ACHTUNG Messungen nur an spannungsfreien Schaltungen bzw Bauteilen vornehmen Zur Messung wie beschrieben verfahren Funktions Bereichwahlschalter in St
15. e P 1615 Die Taste dient zur Nulleinstellung bei DC Messungen Vor Beginn der Messung DC Taste dr cken bis in der LCD Anzeige der Wert 0 angezeigt wird 6 Messbetrieb ACHTUNG Vor Aufnahme des Messbetriebes Ger t und Zubeh r auf eventuelle Besch digungen kontrollieren Pr fleitungen auf Knicke und oder blanke Dr hte berpr fen Bei Anschluss an das Zangenmessger t Pr fleitungen auf festen Sitz in den Anschlussbuchsen berpr fen Bestehen Zweifel am einwandfreien Zustand des Ger tes oder Zubeh rs keine Messungen vornehmen und das Ger t durch Fachpersonal berpr fen lassen 6 1 Spannungsmessungen 1 Messschaltung spannungslos schalten und Kondensatoren ent laden 2 Gew nschte Messfunktion AC DC und erforderlichen Mess bereich mit dem Funktions Bereichswahlschalter w hlen Bei unbekannten Messgr en aus Sicherheitsgr nden immer den h chsten Messbereich w hlen und falls erforderlich sp ter auf einen niedrigeren Bereich umschalten 3 Schwarze Pr fleitung an den COM Eingang des Ger tes anschlie en 4 Rote Pr fleitung an den V Q Eingang anschlie en und beide Pr fleitungen ber die zu messende Spannungsquelle anlegen Betriebsspannung wieder an die Messschaltung anlegen und Messwert in der LCD Anzeige ablesen ACHTUNG Maximal zul ssige Eingangsspannung von 600 V AC DC nicht berschreiten Bei berschreitung besteht die Gefahr schwerer Verletzungen durch Stromschlag und oder die
16. ellung gt drehen Schwarze Pr fleitung an den COM Eingang und rote Pr fleitung an den V Q Eingang anschlie en Rote Pr fleitung an Anodenseite schwarze Pr fleitung an Kathodenseite der Diode anlegen Spannungsabfall in der LCD Anzeige ablesen Der Spannungsab fall f r Siliziumdioden betr gt typisch 0 7 V f r Germanium Dioden 0 4 V Bei falsch gepolten Pr fleitungen und bei offener Diode wird in der LCD Anzeige OL angezeigt Nach beendeter Messung Pr fleitungen vom Bauteil und den Eing ngen des Zangenmessger tes abziehen 17 To avoid electric shock do not operate this product in wet or damp conditions Conduct measuring works only in dry clothing and rubber shoes i e on isolating mats Never touch the tips of the test leads or probe Comply with the warning labels and other info on the equipment Always start with the highest measuring range when measuring unknown values Do not subject the equipment to direct sunlight or extreme temperatures humidity or dampness Do not subject the equipment to shocks or strong vibrations Do not operate the equipment near strong magnetic fields motors transformers etc Keep hot soldering irons or guns away from the equipment Allow the equipment to stabilize at room temperature before taking up measurement important for exact measurements Do not input values over the maximum range of each measurement to avoid damages of the meter Do not turn the rotary fu
17. en 89 336 EWG elektromagnetische Kompatibilit t und 73 23 EWG Niederspannung entsprechend der Festlegung im Nachtrag 93 68 EWG CE Zeichen berspannungskategorie III 600V Verschmutzungsgrad 2 CAT I Signalebene Telekommunikation elektronische Ger te mit geringen transienten berspannungen CAT Il Fur Hausger te Netzsteckdosen portable Instrumente etc CAT Ill Versorgung durch ein unterirdisches Kabel Festinstallierte Schalter Sicherungsautomaten Steckdosen oder Sch tze CAT IV Ger te und Einrichtungen welche z B ber Freileitungen versorgt werden und damit einer st rkeren Blitzbeeinflussung ausgesetzt sind Hierunter fallen z B Hauptschalter am Stromeingang berspannungsableiter Stromverbrauchsz hler und Rundsteuerempf nger Zur Betriebssicherheit des Ger tes und zur Vermeidung von schweren Verletzungen durch Strom oder Spannungs berschl ge bzw Kurzschl sse sind nachfolgend aufgef hrte Sicherheitshinweise zum Betrieb des Ger tes unbedingt zu beachten Sch den die durch Nichtbeachtung dieser Hinweise entstehen sind von Anspr chen jeglicher Art ausgeschlossen Dieses Ger t darf nicht in hochenergetischen Schaltungen verwendet werden Maximal zul ssige Eingangsspannungen von 600V AC DC nicht berschreiten Maximal zul ssige Eingangswerte unter keinen Umst nden berschreiten schwere Verletzungsgefahr und oder Zerst rung des Ger tes Die angegebenen maximalen Eingangsspannungen d
18. ence value Press and hold down the ZERO button for 2 seconds to exit the relative mode In the relative mode the value shown on the LCD is always The difference between the stored reference value and the present reading For example if the reference value is 24 000 V and the present reading is 12 50 V the display will indicate 11 50 V If the new reading is the same as the reference value the display will be zero This feature also is made as DCA ZERO adjustment Transformer jaws Pick up the AC or DC current flowing through the conductor The marking on the jaw indicates direction of DC Current existing on the conductor being tested which follows forward and vertically with jaws and reading shown on display is positive Peak Button P 1625 This measurement function is used to measure the peak value of a signal It is useable with AC current measurements To use this function select the function and range and press the peak hold switch When this is done the P will appear in the display Next by inputting a signal the peak hold function operates This peak hold value is held in digital memory for a long period To cancel the function press the peak hold switch once again Trigger Press the lever to open the transformer When the lever is released the jaws will close again ZERO P 1615 Before taking DCA measurements push and hold the ZERO button until display indicates zero This button does not work on other f
19. esistance measurements for accuracy Select lowest resistance range and make the test leads short together The display value is the test lead resistance to be subtracted 7 After completing measurement disconnect the DCM test leads 6 4 Continuity testin 1 Select the position by turning the rotary selector switch 2 Follow step 2 and 4 as for resistance measurements 3 An audible tone will sound for resistance less than approx 35 Q P 1625 or 100 Q P 1610 P 1615 After all measurements are completed disconnect the test leads from the circuit and from the DCM input terminals 6 5 Diode testin CAUTION Measurements must only be made with the circuit power OFF 36 1 2 3 4 Set the rotary selector switch to the gt position Follow steps 2 and 4 as for resistance measurements The red test lead should be connected to the anode and the black lead to the cathode For a silicon diode the typical forward voltage should be about 0 7 V or 0 4 V for a germanium diode If the diode is reverse biased or there is an open circuit the display shows OL 6 6 Capacitance measurement 1 N D Turn off power to the device under test and discharge all capacitors Discharge all voltage from the capacitor before measuring its capacitance value Note A safe way to discharge a capacitor is to connect a 100 kQ resistor across the two capacitor leads Set the rotary selector switch to the capa
20. g 11 VQ Buchse COM Eingangsbuchse Zum Anschluss der schwarzen Pr fleitung bei allen Messfunktionen ausgenommen Strommessungen V Hz Q Eingangsbuchse Zum Anschluss der roten Pr fleitung bei Spannungs Frequenz Kapazit ts und Widerstandsmessungen sowie f r die Durchgangs und Diodenpr ffunktionen des Ger tes LCD Anzeige Messwertanzeige mit automatischer Anzeige der Funktionssymbole Bereichs Funktionswahlschalter Zur Wahl der Messfunktion und des gew nschten Bereiches Taste zur manuellen Bereichswahl Range Beim Dr cken der Taste wird automatisch auf manuelle Bereichswahl umgeschaltet das Funktionssymbol AUTO erlischt Bei Umschaltung auf die manuelle Bereichswahl bleibt der vor der Umschaltung zuletzt gew hlte Bereich erhalten Zur nderung des Bereiches Taste RANGE wiederholt dr cken bis der gew nschte Bereich angezeigt wird 12 Abb 5 2 Vorderansicht der Ger te P 1615 u P 1625 11 4 6 Capacitance Model Range Resolution Accuracy P 1610 40nF 10pF 5 0 rdg 100 dgt 400nF 100pF 3 0 rdg 5 dgt 4uF 1nF 3 5 rdg 5 dgt 40uF 10nF 100uF 100nF 5 0 rdg 5 dgt P 1615 40nF 10pF 5 0 rdg 100 dgt 400nF 100pF 3 0 rdg 5 dgt 4uF 1nF 3 5 rdg 5 dgt 40uF 10nF 100uF 100nF 5 0 rdg 5 dgt P 1625 4nF 1pF 5 0 rdg 30 dgt 40nF 10pF 5
21. ge der Funktions symbole P 1615 3 stellige 17 mm LCD Anzeige mit einer max Anzeige von 4000 und Anzeige der Funktions symbole P 1625 3 stellige 15 mm LCD Anzeige mit einer max Anzeige von 4000 und Anzeige der Funktions symbole 42 Segment Analog Balkengrafik Polaritat automatische Umschaltung bei negativen Mess werten Minussymbol vor der Messwertanzeige Uberlastanzeige OL im Anzeigefeld Batteriezustands Batteriesymbol leuchtet bei ungen gender Bat anzeige teriespannung Messfolge 2 x pro Sekunde 20 x pro Sek analoge Balkengrafik P 1625 2 x pro Sekunde P 1610 P 1615 Abschaltautomatik P 1610 30 Minuten P 1615 35 Minuten P 1625 20 Minuten Spannungsver sorgung 9 V Blockbatterie Max Leiterdurch messer 30 mm Betriebstemp bereich 10 50 C bei max 85 R H Lagertemp bereich 30 60 C bei max 85 R H 4 Vermeiden Sie jegliche N he zu explosiven und entflammbaren Stoffen ffnen des Ger tes und Wartungs und Reparaturarbeiten d rfen nur von qualifizierten Service Technikern durchgef hrt werden Ger t nicht mit der Vorderseite auf die Werkbank oder Arbeitsfl che legen um Besch digung der Bedienelemente zu vermeiden Messger te geh ren nicht in Kinderhande 1 Am_Ger t befindliche Hinweise und Symbole ACHTUNG Entsprechende Abschnitte in der Bedienungs anleitung beachten Hochspannung Vorsicht extreme Verletz
22. ircuit Users should exercise care and take appropriate precautions to avoid misleading results when making measurement in the presence of electromagnetic interference 2 Introduction 2 1 Unpacking and inspection Upon removing your new digital clamp meter from its packing you should have the following items Digital clamp meter Test lead set 9 V battery installed in meter Carrying case Instruction manual Thermocouple If any of the above items are missing or are received in a damaged condition please contact the distributor from whom you purchased the unit 23 Widerstandsmessungen nur an spannungsfreien Schaltungen bzw Bauteilen vornehmen Die Widerstandsschaltung des Ger tes ist mit einer elektronischen berlastschutzschaltung abgesichert Eine Besch digung des Ger tes ist daher unwahrscheinlich aber nicht v llig auszuschlie en Dies gilt auch f r die Gefahr eines elektrischen Stromschlages bei unsachgem em Gebrauch des Ger tes Zur Messung wie beschrieben verfahren 1 Zu messenden Widerstand bzw zu messende Schaltung span nungslos schalten und Kondensatoren in der Schaltung entladen ACHTUNG Widerstandsmessungen an spannungsf hrenden Bauteilen k nnen bei berschreitung des max berlastschutzes von 250 V AC DC das Ger t besch digen 2 Schwarze Pr fleitung an den COM Eingang und rote Pr fleitung an den V Q Eingang anschlie en 3 Funktions Bereichswahlschalter in Stellung Q drehe
23. itig kalibriert geliefert wird Eine Wiederholung der Kalibrierung nach Ablauf von 1 Jahr wird empfohlen PeakTech 02 2008 Th 20 1 Safety Precautions This product complies with the requirements of the following European Community Directives 89 336 EC Electromagnetic Compatibility and 73 23 EC Low Voltage as amended by 93 68 EC CE Marking Overvoltage category III 600V pollution degree 2 CAT I For signal level telecommunication electronic with small transient over voltage CAT Il For local level appliances main wall outlets portable equipment CAT Ill Distribution level fixed installation with smaller transient overvoltages than CAT IV CAT IV Units and installations which are supplied overhead lines which are stand in a risk of persuade of a lightning i e main switches on current input overvoltage diverter current use counter To ensure safe operation of the equipment and eliminate the danger of serious injury due to short circuits arcing the following safety precautions must be observed Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever Do not use this instrument for high energy industrial installation measurement Do not exceed the maximum permissible input ratings danger of serious injury and or destruction of the equipment The meter is designed to withstand the stated max voltages If it is not possible to exclude witho
24. ition error 1 of reading 4 4 AC Current Model Range Resolution Accuracy P1610 40A 10 mA 2 5 rdg 10 dgt 400A 100 mA 2 5 rdg 5 dgt 1000 A 1A 3 0 rdg 4 dgt P 1615 40A 10 mA 3 0 rdg 10 dgt 400 A 100 mA 3 0 rdg 5 dgt 1000 A 1A 3 0 rdg 5 dgt P 1625 40A 10 mA 2 8 rdg 10 dgt True 400 A 100 mA 2 8 rdg 8 dgt RMS 1000 A 1A 3 0 rdg 8 dgt Overload protection 1000 A PeakTech 1610 1615 Position error 1 of reading 26 4 5 Resistance Model Range Resolution Accuracy P1610 400Q 100 mQ 1 0 rdg 4 dgt 4kQ 19 40 KQ 1009 1 5 rdg 2 dgt 400 kQ 100 Q 4MQ 1kQ 2 5 rdg 3 dgt 40 MQ 10 kQ 3 5 rdg 5 dgt P1615 4000 100 mQ 1 0 rdg 4 dgt 4kQ 19 40 KQ 1009 1 5 rdg 2 dgt 400 kQ 100 Q 4 MQ 1kQ 2 5 rdg 3 dgt 40 MQ 10 kQ 3 5 rdg 5 dgt P1625 4000 100 mQ 1 0 rdg 4 dgt 4kQ 10 40 KQ 10 Q 1 5 rdg 2 dgt 400 KQ 100 Q 4 MQ 1kQ 2 5 rdg 5 dgt 40 MQ 10 kQ 3 5 rdg 10 dgt Overload protection 250 V AC DC 27 1 Zange 2 Zangen ffner 3 P 1615 Taste f r Data Hold Hintergrundbeleuchtung P 1625 Taste f r Data Hold 4 Mode Taste 5 P 1615 Hz Taste P 1625 Peak Hold Taste 6 LCD Display 7 COM Eingang 8 Funktionswahlschalter 9 Zero Taste 10 P 1615 Bereichswahltaste P 1625 Taste f r Hintergrundbeleuchtun
25. n 4 Pr fleitungen ber den zu messenden Widerstand anlegen vorher sicherstellen dass Widerstand spannungslos ist 5 Widerstandswert in der LCD Anzeige ablesen Bei offenen Wider st nden erscheint in der LCD Anzeige das berlastsymbol OL 6 Nach beendeter Messung Pr fleitungen von der Messschaltung und den Eing ngen des Zangenmessger tes abziehen Hinweis Der Eigenwiderstand der Pr fleitungen kann bei Messungen von geringen Widerst nden die Genauigkeit der Messung negativ beeintr chtigen Der Eigenwiderstand blicher Pr fleitungen liegt zwischen 0 1 und 0 2 Q Zur genauen Bestimmung des Eigenwiderstandes Pr fleitungen an die Eingangsbuchsen des Zangenmessger tes anschlie en niedrigsten Widerstandsbereich w hlen und Pr fleitungen kurz schlie en Der angezeigte Messwert entspricht dem Eigenwiderstand der Pr fleitungen und muss vom Messergebnis abgezogen werden 16 5 Nach Durchf hrung s mtlicher Messungen Messschaltung wieder spannungslos schalten Kondensatoren entladen und Pr f leitungen anschlie end von der Messschaltung abziehen 6 2 Strommessungen ACHTUNG Die Transformatorzange ist f r Strommessungen mit einem maximalen Spannungsunterschied von 600 V zwischen dem zu messenden Leiter und Massepotential ausgelegt Strommessungen an Leitern mit einem h heren Spannungsunterschied in Bezug auf Masse k nnen zur Besch digung des Zangenmessger tes der Mess schaltung und oder Verletzungen
26. nction switch during voltage or current measurement otherwise the meter could be damaged Use caution when working with voltages above 35V DC or 25V AC These Voltages pose shock hazard Replace the battery as soon as the battery indicator BAT appears With a low battery the meter might produce false reading that can lead to electric shock and personal injury Fetch out the battery when the meter will not be used for long period Periodically wipe the cabinet with a damp cloth and mid detergent Do not use abrasives or solvents The meter is suitable for indoor use only Do not operate the meter before the cabinet has been closed and screwed safely as terminal can carry voltage Do not store the meter in a place of explosive inflammable substances Do not modify the equipment in any way Opening the equipment and service and repair work must only be performed by qualified service personnel Measuring instruments don t belong to children hands 22 1 Safety information Caution Refer to accompanying documents Caution Risk of electric shock Equipment protected throughout by double insulation class II oS e Alternatina current Direct current H Ground However electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit Measuring instruments will also respond to unwanted signals that may be present within the measurement c
27. nuity Model Audible Threshold Test current P 1610 lt 1000 P 1615 lt 1002 lt 1mA P 1625 lt 350 Overload protection 250 V AC DC 4 11 Diode test Model Test current Open circuit voltage P 1610 P 1615 0 3 mA 1 5V P 1625 Overload protection 250 V AC DC 29 5 Bedienelemente und Anschl sse am Ger t Abb 5 1 Vorder u R ckansicht des Ger tes P 1610 1 Zange 3 Taste f r Data Hold 5 7 9 11 Batteriefachdeckel N O 2 Hintergrundbeleuchtung 4 LCD Display Funktionswahlschalter Hz duty Taste 6 8 10 10 Fi Zangen ffner Mode Taste COM Eingang Bereichswahltaste VQ C F Buchse 4 8 Arbeitszyklus Modell Bereich Aufl sung Genauigkeit P 1610 0 5 99 0 0 1 1 2 v M 2 dgt Pulsweite 100 us 100 ms P1615 0 5 99 0 0 1 1 2 v M 2 dgt Pulsweite 100 us 100 ms Frequenz 5 Hz 100 kHz Uberlastschutz 250 V AC DC 4 9 Temperaturmessungen Modell Bereich Aufl sung Genauigkeit P 1610 50 400 C 0 1 C 3 0 v M 5 dgt 400 1000 C 1 C 58 400 F 0 1 F 3 0 v M 7 dgt 400 1832 F 1 F P 1615 20 1000 C 1 C 3 0 v M 5 dgt 4 1832 F 1 F 3 0 v M 7 dgt P 1625 40 1000 C 1 C 2 5 v M 3 dgt 40 1832 F 1 F
28. press the MODE button to select the F unit P 1610 P 1625 7 Replacing the battery WARNING To avoid electrical shock disconnect the test leads and any input signals before replacing the battery Replace only with same type of battery This meter is powered by a NEDA type 1604 or equivalent 9 V battery When the meter displays the battery symbol the battery must be replaced to maintain proper operation Use the following procedure to replacing the battery 38 1 Disconnect test leads from any live source turn the rotary switch to OFF and remove the test leads from the input terminals 2 The battery cover is secured to the bottom case by a screw Using a Philips head screwdriver remove the screw from the battery cover and remove the battery cover 3 Remove the battery and replace with a new equivalent 9 V battery 4 Replace the battery cover and reinstall the screw Note Batteries which are used up dispose duly Used up batteries are hazardous and must be given in the for this being supposed collective container 8 Maintenance Maintenance consists of periodic cleaning and battery replacement The exterior of the instrument can be cleaned with a dry clean cloth to remove any oil grease or grime Never use liquid solvents or detergents Repairs or servicing not covered in this manual should only be performed by qualified service personnel All rights also for translation reprinting and copy of this manual o
29. r parts are reserved Reproductions of all kinds photocopy microfilm or other only by written permission of the publisher This manual considers the latest technical knowing Technical changings which are in the interest of progress reserved We herewith confirm that the units are calibrated by the factory according to the specifications as per the technical specifications We recommend to calibrate the unit again after 1 year PeakTech 02 2008 Th 39 PeakTech PeakTech 1610 1615 1625 Bedienungsanleitung Operation manual Digital Zangenmessger te Digital Clamp Meters Spitzentechnologie die berzeugt
30. r N he starker magnetischer Felder Motoren Transformatoren usw betreiben Hei e L tpistolen aus der unmittelbaren N he des Ger tes fernhalten Vor Aufnahme des Messbetriebes sollte das Ger t auf die Umgebungstemperatur stabilisiert sein wichtig beim Transport von kalten in warme R ume und umgekehrt berschreiten Sie bei keiner Messung den eingestellten Messbereich Sie vermeiden so Besch digungen des Ger tes Drehen Sie w hrend einer Strom oder Spannungsmessung niemals am Messbereichswahlschalter da hierdurch das Ger t besch digt wird Messungen von Spannungen ber 35 V DC oder 25 V AC nur in bereinstimmung mit den relevanten Sicherheitsbestimmungen vornehmen Bei h heren Spannungen k nnen besonders gef hrliche Stromschl ge auftreten Ersetzen Sie die Batterie sobald das Batteriesymbol BAT aufleuchtet Mangelnde Batterieleistung kann unpr zise Mess ergebnisse hervorrufen Stromschl ge und k rperliche Sch den k nnen die Folge sein Sollten Sie das Ger t f r einen l ngeren Zeitraum nicht benutzen entnehmen Sie die Batterie aus dem Batteriefach S ubern Sie das Geh use regelm ig mit einem feuchten Stofftuch und einem milden Reinigungsmittel Benutzen Sie keine tzenden Scheuermittel Dieses Ger t ist ausschlie lich f r Innenanwendungen geeignet Keine technischen Ver nderungen am Ger t vornehmen 2 1 Sicherheitshinweise zum Betrieb des Ger tes Dieses Ger t erf llt die EU Bestimmung
31. t 6 max Betriebsh he 3 000 m U M Abmessungen 80 B x 229 H x 40 T mm Gewicht 300 g 3 1 Maximal zul ssige Eingangswerte Funktion Max Eingang AAC D CA P 1615 P 1625 1000 A V DC V AC 600 V DC AC Widerstand Diode Durchgangs 250 V DC AC pr fung Frequenz Arbeitszyklus Kapazit t Temperatur C F 60 V DC 24 VAC 4 Spezifikationen 4 1 Gleichspannung Modell Bereich Aufl sung Genauigkeit P 1610 400mV 100uV 0 8 v M 3 dgt 4V 1mV 40V 10mV 1 5 v M 3 dgt 400V 100mV 600V 1V 2 0 v M 3 dgt P 1615 400mV 100uV 0 8 v M 3 dgt 4V 1mV 40V 10mV 1 5 v M 3 dgt 400V 100mV 600V 1V 2 0 v M 3 dgt P 1625 400mV 100uV 0 8 v M 2 dgt 4V 1mV 40V 10mV 1 5 v M 2 dgt 400V 100mV 600V 1V 2 0 v M 2 dgt Uberlastschutz 600V AC DC 252 6 How to make measurements Before making any measurements read safety precautions Always examine the instrument and accessories used with the instrument for damage contamination excessive dirt grease etc and defects Examine the test leads for cracked or frayed insulation and make sure the lead plugs fit snugly into the instrument terminals If any abnormal conditions exist do not attempt to make any measurements 6 1 Voltage measurements 1 Turn off power to the device under test and discharge all capacitors 2 Plug the bla
32. tes bei Wechselstrommessungen Zur Aktivierung der Spitzenwert Haltefunktion Wechselstrommessfunktion und bereich mit dem Funktions Bereichswahlschalter w hlen und anschlie end die PEAK Taste dr cken Das Funktionssymbol P erscheint in der Anzeige Der Spitzenwert des anliegenden Signals wird im digitalen Speicher des Ger tes langfristig gespeichert Zur R ckkehr zu normalen Messbetrieb PEAK Taste erneut dr cken Zangen ffner Zum ffnen der Zange Beim Loslassen des Zangen ffners wird Die Zange automatisch wieder geschlossen 13 4 2 AC Volts Model Range Resolution Accuracy P 1610 400mV 100uV 0 8 rdg 20 dgt 4V 1mV 40V 10mV 1 8 rdg 5 dgt 400V 100mV 600V 1V 2 5 rdg 5 dgt P 1615 400mV 100uV 0 8 rdg 20 dgt 4V 1mV 40V 10mV 1 8 rdg 5 dgt 400V 100mV 600V 1V 2 5 rdg 5 dgt P 1625 400mV 100uV 1 0 rdg 10 dgt True 4V 1mV RMS 40V 10mV 1 5 rdg 8 dgt 400V 100mV 600V 1V 2 0 rdg 8 dgt Overload protection 600 V AC DC 4 3 DC Current Model Range Resolution Accuracy P 1615 40 A 10 mA 2 8 rdg 10 dgt 400 A 100 mA 2 8 rdg 5 dgt 1000 A 1A 3 0 rdg 5 dgt P 1625 40A 10 mA 2 8 rdg 10 dgt 400 A 100 mA 2 8 rdg 8 dgt 1000 A 1A 3 0 rdg 8 dgt Overload protection 1000 A PeakTech 1615 Pos
33. unctions ranges 33 4 2 Wechselspannung Modell Bereich Aufl sung Genauigkeit P 1610 400mV 100uV 0 8 v M 20 dgt 4V 1mV 40V 10mV 1 8 v M 5 dgt 400V 100mV 600V 1V 2 5 v M 5 dgt P 1615 400mV 100uV 0 8 v M 20 dgt 4V 1mV 40V 10mV 1 8 v M 5 dgt 400V 100mV 600V 1V 2 5 v M 5 dgt P 1625 400mV 100uV 1 0 v M 10 dot Echt 4V 1mV Effektiv 40V 10mV 1 5 v M 8 dgt 400V 100mV 600V 1V 2 0 v M 8 dgt berlastschutz 600 V AC DC 4 3 Gleichstrom Modell Bereich Aufl sung Genauigkeit P 1615 40A 10 mA 2 8 v M 10 dgt 400A 100 mA 2 8 v M 5 dgt 1000 A 1A 3 0 v M 5 dgt P1625 40A 10 mA 2 8 v M 10 dgt 400 A 100 mA 2 8 v M 8 dgt 1000 A 1A 3 0 v M 8 dgt berlastschutz 1000 A PeakTech 1615 Positionsfehler 1 v Messwert 4 4 Wechselstrom Modell Bereich Aufl sung Genauigkeit P1610 40A 10 mA 2 5 v M 10 dgt 400A 100 mA 2 5 v M 5 dgt 1000 A 1A 3 0 v M 4 dgt P 1615 40A 10 mA 3 0 v M 10 dgt 400 A 100 mA 3 0 v M 5 dgt 1000 A 1A 3 0 v M 5 dgt P1625 40A 10 mA 2 8 v M 10 dgt Echt 400 A 100 mA 2 8 v M 8 dgt Effektiv 1000 A TA 3 0 v M 8 dgt berlastschutz 1000 A PeakTech 1610 1615 Positionsfehler 1 v Messwer
34. ungsgefahr durch elektrischen Schock Doppelt isoliert GE Wechselstrom H Gleichstrom Masse Messungen nahe starken magnetischen Feldern oder elektrischen St rfeldern k nnen das Messergebnis negativ beeintr chtigen Dar ber hinaus reagieren Messger te empfindlich auf elektrische St rsignale jeglicher Art Dies sollte beim Messbetrieb durch entsprechende Schutzma nahmen ber cksichtigt werden 1 2 Auspacken des Ger tes und berpr fen d Lieferumfanges Ger t vorsichtig aus der Verpackung nehmen und Lieferung auf Voll st ndigkeit berpr fen Zum Lieferumfang geh ren Zangenmessger t Pr fleitungen Batterie Tragetasche Bedienungs anleitung Temperaturf hler Sch den bzw fehlende Teile bitte sofort beim zust ndigen H ndler reklamieren 3 1 Turn off any power to the resistor to be measured Discharge capacitors Any voltage present during a resistance measurement will cause inaccurate readings and could damage the meter if exceeding the overload protection of 250 V DC or AC 2 Insert the black and red test leads into the COM and V Q input terminals respectively 3 Select the desired ohm Q range 4 Connect the black and red test probe tips to the circuit or device under test making sure it is de energized first 5 Open circuits will be displayed as an overload condition 6 Test lead resistance can interfere when measuring low resistance readings and should be subtracted from r
35. ut that impulses transients disturbance or for other reasons these voltages are exceeded a suitable prescale 10 1 must be used Disconnect test leads or probe from the measuring circuit before switching modes or functions To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements Do not conduct current measurements with the leads connected to the V Q terminals of the equipment Check test leads and probes for faulty insulation or bare wires before connection to the equipment 21 6 6 Kapazitatsmessungen ACHTUNG Kondensatoren k nnen sehr hohe Spannungen speichern Kondensator vor der Messung daher unbedingt entladen Dazu einen Widerstand von 100 kQ ber die Kondensatoranschl sse legen Den Kontakt bzw die Ber hrung mit blanken Dr hten unbedingt vermeiden Verletzungsgefahr durch elektrischen Schock Der Versuch unter Spannung stehende Kondensatoren zu messen kann zur Besch digung des Zangenmessger tes f hren Kapazit t wie beschrieben messen 1 Messschaltung spannungslos schalten und alle Kondensatoren entladen 2 Funktions Bereichswahlschalter auf Kapazit tsbereich stellen 3 Schwarze Pr fleitung an den COM Eingang und rote Pr fleitung an den V Q Eingang anschlie en Bei polarisierten Konden satoren unbedingt Polarit t beachten Rote Pr fleitung an Plus anschluss schwarze Pr fleitung an Minusanschluss