1. OO K een Tree Display 2 2 1 Channel display Co I m Um xO channel display 33 The controller is operated via the 3 push buttons below the display The forward button 1 Is used for scrolling forward through the display menu or to increase the adjustment values The backward button 2 is similarly used for scrolling backwards and reducing values In order to access the adjustment mode scroll down in the diplay menu and press the forward button 1 for approx 3 seconds after you have reached the last diplay item If an adjustment value is shown on the display the SET icon is displayed Now you can access the adjustment mode by using button 3 Press buttons 1 and 2 in order to select a channel Briefly press button 3 SET will flash Adjust the value by pressing buttons 1 and 2 Briefly press buttons 3 so that SET permanently appears the adjusted value will be saved The system monitoring display consists of 3 blocks channel display tool bar and system screen active arrangement The channel display consists of two lines The upper line is an alpha numeric 16 segment display text dis play for displaying channel names and menu items In the lower 7 segment display the channel values and the adjustment parameters are displayed Temperatures and temperature differences are indica ted in C or K respectively 34 2 Operation and function 2 2 2 Tool bar The additional symbols in the tool bar
2. cklauf S4 wird die transportierte W rmemenge gemessen Diese wird in kWh Anteilen im Anzeigekanal kWh und in MWh Anteilen im Anzeigekanal MWh angezeigt Die Summe beider Kan le bildet den gesamten W rmeertrag Die aufsummierte Warmemenge kann zur ckgesetzt werden Sobald einer der Anzeigekan le der W rme menge angew hlt ist erscheint im Display dauerhaft das Symbol Sai Die Taste SET 3 muss ca 2 Sekunden lang gedr ckt werden um in den RESET Modus des Zahlers zu gelangen Das Display Symbol blinkt und der Wert f r die Warmemenge wird auf O zur ckgesetzt Um den RESET Vorgang abzuschlie en muss mit der Taste best tigt werden Soll der RESET Vorgang abgebrochen werden muss ca 5 Sekunden gewartet werden Der Regler springt danach automatisch in den Anzeigemodus zur ck 15 3 Regelparameter und Anzeigekanale 3 1 9 AT Regelung DT E Einschalttemperatur nn a differenz UI Lem Einstellbereich 1 0 20 0K Er Werkseinstellung 6 0 DT A Ausschalttemperaturdifferer m F Einstellbereich 0 5 19 5K wal nu Werkseinstellung 4 0 K HU k Hinweis Die Einschalt Temperaturdifferenz muss min destens 1K gr er als Ausschalt Temperaturdifferenz sein DT S Solltemperaturdifferenz qT G zu Einstellbereich 1 5 30 0K an Werkseinstellung 10 0 III K ANS Anstieg Einstellbereich 1 20K NICS Werkseinstellung 2 K AND C K 3 1 10 Speicher Maximaltemperatur S MX Speichermaximal ATE temperatur Jl A a Ei
3. Elektrostatische Entladung kann zur Sch digung elektronischer Bauteile f hren AN Ber hrungsgef hrliche Spannungen Die Stromversorgung des Reglers muss ber einen externen Netzschalter erfolgen letzter Arbeitsschritt und die Versorgungsspannung muss 220 240 V 50 60 Hz betragen Flexible Leitungen sind mit den beiliegenden Zugentlastungsbugeln und den zugeho rigen Schrauben am Geh use zu fixieren Der Regler ist mit 2 Relais ausgestattet an die Ver braucher wie Pumpen Ventile o a angeschlossen werden k nnen e Relais 1 18 Leiter R1 17 Nullleiter N 13 Erdungsklemme e Relais 1 V 16 Leiter R1 V Ventil 15 Nullleiter N 14 Erdungsklemme amp Die Temperatursensoren S1 bis S4 werden mit beliebiger Polung an den folgenden Klemmen ange schlossen 1 2 Sensor 1 z B Sensor Kollektor 1 3 4 Sensor 2 z B Sensor Speicher 1 5 6 Sensor 3 z B Sensor TSPO 7 8 Sensor 4 z B Sensor TRL Der Netzanschluss erfolgt an den Klemmen 19 Nullleiter N 20 Leiter L 12 Erdungsklemme amp 1 Installation 1 2 1 Datenkommunikation Bus R1 1 1 A 220 240 V R1 V 2 1 A 220 240 V Temp Sensor Pt1000 S2 VBus Anschlussklemmen 1 2 2 Klemmenbelegung Anlage 1 Der Regler verfugt Uber den VBus zur Datenkommu nikation mit und der Energieversorgung von externen Modulen Der Anschluss erfolgt mit beliebiger Polung an den beiden mit VBus geken
4. N y _ 6 5 co g Ge m N 14 _ 110 13 47 Technische Daten Gehause Kunststoff PC ABS und PMMA Schutzart IP 20 DIN 40050 Umgebungstemp 0 40 C Abmessung 172 x 110 x 46 mm Einbau Wandmontage Schalttafel Einbau m glich Anzeige System Monitor zur Anlagenvisualisierung 16 Segment Anzeige 7 Segment Anzeige 8 Symbole zum Systemstatus und Betriebskontrolllampe Bedienung ber drei Drucktaster in Geh usefront Funktionen Temperaturdifferenzreglermit optional zuschaltbaren Anlagenfunktionen Funktionskontrolle gem BAW Richtlinie Betriebsstundenz hler f r die Solarpumpe R hrenkollektorfunktion Drehzahlrege lung und W rmemengenbilanzierung Eing nge f r 4 Temperatursensoren Pt1000 Ausg nge 1 Halbleiterrelais 1 Standardrelais Bus VBus Versorgung 220 240 V Gesamtschaltleistung 4 2 A 220 240 V Wirkungsweise Typ 1 y Schaltleistung pro Relais Halbleiterrelais 1 1 A 220 240 V Elektromechanisches Relais 2 1 A 220 240 V C e 1 Installation Anwendungsbeispiele Deltasol BS Standard Solarsysteme 1 1 Montage Display Blende Drucktaster Kabeldurchf hrungen mit Zugentlastungsbugeln Topfsicherung T4A Aufh ngung 104 Befestigung Ausf hrliche Anschlusspl ne zu den aufgezeigten Systemen find
5. indicate the actual system status ke A200 flashing kea active tool bar relay 2 active store maximum limitation active maximum store temperature exceeded collector minimum limita ntifreeze function acti o aa tion or antifreeze function active collector emergency shut down or store emergency shutdown active collector cooling function or recooling function active manual operation active SET mode change of ad justment value is possible 35 2 Operation and function 2 2 3 System screen The system screen active arrangement shows the um scheme which has been selected The screen consists N of several system component symbols which are depending on the current status of the system either 23 flashing permanently shown or hidden system Screen ur store top sensor oe 2 WW Pa collector 1 sensor Ya X collectors with collector sensor store with heat exchanger pumps After heating with burner symbol store heat exchanger store C temperature sensor store 2 or after heating with additional symbol additional symbol ope pump ration of the burner 2 3 Flashing codes e Pump symbols are flashing during 2 3 1 System screen codes u Ea e Sensor symbols are flashing if the corresponding sensor display channel is selected e Sensor symbols are flashing in the case of a sensor fault e Burner symbol is flashing if the after heating is active 2 3 2 LED flashi
6. range 1 5 30 0K Factory setting 10 0 K RIS Rise JITG Adjustment range ret a Taa ZOK LK Factory setting 2 K 3 1 10 Maximum store temperature S MX Maximum store temp M Adjustment range 2 95 C Factory setting 60 C D This function is a standard differential control If the switch on differential is reached DT O the pump is operated The pump runs at 100 speed for 10 seconds After this period the pump runs at minimum pump speed NMN 30 If the temperature difference reaches the adjusted set value DT S pump speed will increase by one step 10 If the difference increases by 2 K RIS pump speed will increase by 10 respectively until the maximum pump speed of 100 is reached The response of the controller can be adapted via the parameter Rise If the temperature difference falls below the adjusted switch off temperature difference DT F the controller switches off If the adjusted maximum temperature is exceeded the store will no longer be loaded in order to avoid damage caused by overheating If the maximum store temperature is exceeded will be shown Please note The controller is equipped with a store emergency shutdown function which prevents the store from being loaded when the store temperature exceeds 95 C 40 3 Control parameters and display channels 3 1 11 Collector emergency shutdown temperature f the adjusted collector emergency shutdown EM Col
7. resulting damages Please note The design and the specifications can be changed without prior notice The illustrations may differ from the original product Reprinting copying This mounting and operation manual including all parts is copyrighted Another use outside the copyright requires the approval of COSMO GmbH This especially applies for copies translations micro films and the sto rage into electronic systems Editor COSMO GmbH Brandstucken 31 22549 Hamburg Notes 49 COSMO GUTES KLIMA BESSER LEBEN Samtliche Bild Produkt MaB und Ausfuhrungsangaben entsprechen dem Tag der Drucklegung Technische Anderungen vorbehalten Modell und Produktanspruche konnen nicht geltend gemacht werden Montage und Bedienungsanleitung COSMO Deltasol BS 1 0 06 09 COSMO GmbH
8. x sensor FKP6 2 x sensor FRP6 29 Technichal data and overview of functions e System monitoring display e Up to 4 temperature sensors Pt1000 e Heat quantity measurement e VBus e Function control e User friendly operation through simple handling e Pump speed control and solar operating hours counter mu M 66 r f od Gop 7 i N LJ l 110 N 13 47 Technical data Housing plastic PC ABS and PMMA Protection type IP 20 DIN 40050 Ambient temp 0 40 C Dimensions 172 x 110 x 46 mm Mounting wall mounting mounting into patch panels is possible Display System screen for systems visualisation 16 segment display 7 segment display 8 symbols for system status and operating control lamp Operation 3 push buttons at the front of the housing Functions Differential temperature controller with optional system functions Function control according to BAW guidelines operating hours counter for solar pump tube collector function pump speed control as well as heat quantity measurement The Deltasol BS is a controller for standard solar ther mal systems It provides a clear operating concept and is equipped with a system monitoring display Flashing symbols for sensors pumps and valves show tempe ratures temperature differences and active actuators The Deltasol BS controller is available in 4 versions Inputs for 4 t
9. 3 1 2 Store temperatures TST Store temperatures Display range 40 250 C 3 1 3 Sensor 3 and sensor 4 a a N LI II Loy 3 S3 S4 Temperatures at the sensors S3 and S4 Display range 40 250 C 3 1 4 Time 3 1 5 Other temperatures TRF other measured temperatures Display range 40 250 C 3 1 6 Current pump speed n current pump speed Display range 30 100 IN N La gt m LI Se Se Display of the current collector temperature e COL collector temperature 1 collector system Display of the current store temperature e TST store temperature 1 store system Display of the current temperature at the correspondi ng additional sensor without control function e S3 _ temperature sensor 3 e S4 temperature sensor 4 Please note Only if the temperature sensors are connected dis played will S3 and S4 be displayed In this channel the current time is indicated By pressing button for 2 seconds the hours by pressing it again the minutes are displayed blinking The time can be set by buttons 1 and 2 and saved by pressing the button Display of the current temperature at the sensor e IR temperature return Display of the current pump speed of the corresponding pump e n current pump speed 1 pump system 38 3 Control parameters and display channels 3 1 7 Operating hours counter h P Operating hours counter Displ
10. 49008770 COSMO GUTES KLIMA BESSER LEBEN Deltasol BS Montage und Bedienungsanleitung Deltasol BS Assembly and Operating Constructions Sicherheitshinweise Sicherheitshinweise Bitte beachten Sie diese Sicherheitshinweise genau um Gefahren und Schaden fur Menschen und Sachwerte auszuschlieBen Vorschriften Beachten Sie bei Arbeiten die gesetzlichen Vorschriften zur Unfallverh tung die gesetzlichen Vorschriften zum Umweltschutz die Bestimmungen der Berufsgenossenschatt die einschl gigen Sicherheitsbestimmungen der DIN EN DVGW TRGI TRF und VDE Diese Anleitung richtet sich ausschlie lich an autori sierte Fachkr fte Elektroarbeiten d rfen nur von Elektrofachkr ften durchgef hrt werden Die erstmalige Inbetriebnahme hat durch den Ersteller der Anlage oder einen von ihm benannten Fachkun digen zu erfolgen Bestimmungsgem e Verwendung Der Solarregler ist f r den Einsatz in thermischen Stan dard Solarsystemen unter Ber cksichtigung der in dieser Anleitung angegebenen technischen Daten bestimmt Die bestimmungswidrige Verwendung f hrt zum Aus schluss jeglicher Haftungsanspr che Konformit tserkl rung Das Produkt entspricht den relevanten Richt linien und ist daher mit der CE Kennzeich nung versehen Die Konformit tserkl rung kann beim Hersteller angefordert werden Inhaltsverzeichnis 1 INStallatiOn ccccccceeeeseeseeseeseeeseeeeeeeeneaes 4 ll MON nennen
11. T 3 muss ca 2 Sekunden lang gedr ckt werden um in den RESET Modus des Zahlers ZU gelangen Das Display Symbol blinkt und die Betriebsstunden werden auf O zur ckgesetzt Um den RESET Vorgang abzuschlie en muss dieser mit der Taste best tigt werden Um den RESET Vorgang abzubrechen f r ca 5 Sekun den keine Taste bet tigen Der Regler springt automa tisch in den Anzeigenmodus zur ck 14 3 Regelparameter und Anzeigekanale 3 1 3 Warmemengenbilanzierung OWMZ Warmemengen bilanzierung Einstellbereich OFF ON Werkseinstellung OFF VMAX Volumenstrom in min Einstellbereich 0 20 in 0 1 Schritten Werkseinstellung 6 0 MEDT Frostschutzart Einstellbereich 0 3 Werkseinstellung 1 MED Frostschutzgehalt in Vol MED wird bei MEDT O und 3 ausgeblendet Einstellbereich 20 70 Werkseinstellung 45 kWh MWh Warmemenge in kWh MWh Anzeigekanal VMAX AU r it 1 5 Grunds tzlich ist in Verbindung mit einem Flowmeter eine Warmemengenbilanzierung m glich Dazu ist in Kanal OWMZ die Option Warmemengenbilanzierung zu aktivieren Der am Flowmeter abzulesende Volumenstrom l min muss im Kanal VMAX eingestellt werden Frostschutz art und Frostschutzgehalt des Warmetragermediums werden in den Kanalen MEDT und MED angege ben Frostschutzart O Wasser 1 Propylenglykol 2 Ethylenglykol 3 Tyfocor LS G LS Uber die Angabe des Volumenstroms und der Re ferenzsensoren Vorlauf ST und R
12. ation of the heat transfer medium have to be adjusted in the channels MEDT and MED Antifreeze type O water 1 propylene glycol 2 ethylene glycol 3 Tyfocor LS G LS The flow rate as well as the reference sensors S1 flow and S4 return are used for calculating the heat quanti ty supplied It is shown in kWh in the channel kWh and in MWh in the channel MWh The overall heat quantity results from the sum of both values The accumulated heat quantity can be reset AS soon as one of the display channels of the heat quantity Is selected the symbol is permanently shown on the display Press button SET 3 for about 2 seconds in order to access the RESET mode of the counter The display symbol Sag will flash and the heat quantity value will be set to 0 In order to finish this process press the button to confirm In order to interrupt the RESET process no button should be pressed for about 5 seconds The controller automatically returns to the display mode 39 3 Control parameters and display channels 3 1 9 AT regulation DT O Switch on temperature diff Wie m Adjustment range ae ion 1 0 20 0K BU K Factory setting 6 0 DT F Switch off temperature diff m F Bi Adjustment range 0 5 19 5K 4L k Factory setting 4 0 K Please note Switch on temperature difference DO must be at least 1 K higher than the switch off tempe raturedifference DF DT S Set temperature diffe rence Wafa Adjustment
13. ay channel 3 1 8 Heat quantity measurement option OHQM Heat quantity measurement Adjustment range OFF ON Factory setting OFF FMAX Flow rate in l min Adjustment range 0 20 in 0 1 steps Factory setting 6 0 MEDT Antifreeze type Adjustment range 0 3 Factory setting 1 MED Antifreeze con centration Vol When MEDT O or 3 is used the parameter MED is hidden Adjustment range 20 70 Factory setting 45 kWh MWh Heat quantity in kWh MWh Display channel F MAX en baml The operating hours counter accumulates the solar operating hours of the respective relay h P Full hours are displayed The accumulated operating hours can be set back to zero AS soon as one operating hours channel is selected the symbol is displayed Press the SET 3 button for approx 2 seconds in order to access the RESET mode of the counter The display symbol will flash and the operating hours will be set to O Confirm the reset with the button in order to finish the reset In order to interrupt the RESET process do not press a button for about 5 seconds The display returns to the display mode Heat quantity measurement is possible if a flowmeter is used For this purpose the heat quantity measurement option OHQM has to be enabled The flow rate should be read from the flowmeter l min and has to be adjusted in the channel FMAX Antifreeze type and concentr
14. ckflussverhinderer in Vor und R cklauf auf Kollektortemperatur Ist nachts h her als die Au Bentemperatur Funktionst chtigkeit pr fen Speicherisolation ausrel Isolation verst rken Isolation ersetzen oder verst rken Anschl sse isolieren Anschluss zur Seite an dern oder siphoniert ausf hren Bogen nach unten jetzt Speicher Verluste geringer Speicherisolation eng anliegend Speicher Anschlusse isoliert Warmwasserabgang nach oben Warmwasserzirkulation lauft sehr lange Zirkulationspumpe mit Schaltuhr und Abschalt thermostat einsetzen energieefiziente Zirku lation 22 4 Tipps zur Fehlersuche Zirkulationspumpe ab schalten und Absperr ventile fur 1 Nacht ab Sperren Speicherver luste werden geringer Ruckflussverhinderer in der Warmwasserzir kulation kontrollieren OK Die Schwerkraftzirkula tion in der Zirkulations leitung ist zu stark star keren Ruckflussverhin derer einsetzen oder elektr 2 Wege Ventil hin ter Zirkulationspumpe einbauen das 2 Wege Ventil ist bel Pumpen betrieb offen sonst Pumpen des Nachheiz Kreises auf n chtlichen Lauf und defekten R ckflussverhinderer pr fen Problem be hoben weitere Pumpen die mit dem Solarspeicher in Verbindung stehen ebenso berpr fen Reinigen bzw austau schen geschlossen Pumpe und 2 Wege Ventil elek trisch parallel schalten Zirkulation wieder in Betri
15. den gedr ckt halten Wird im Display ein Einstellwert angezeigt erscheint in der Anzeige Sail Danach kann durch Bet tigen der Taste 3 in den Ein gabemodus gewechselt werden e Kanal mit den Tasten 1 und 2 anw hlen e Taste 3 kurz dr cken die Anzeige blinkt E3 Modus e mit den Tasten 1 und 2 den Wert einstellen e Taste 3 kurz drucken die Anzeige Sau erscheint wieder dauerhaft der eingestellte Wert ist abgespeichert Das System Monitoring Display besteht aus 3 Be reichen Der Kanalanzeige der Symbolleiste und dem System Screen aktives Anlagenschema Die Kanalanzeige besteht aus zwei Zeilen Die obere Anzeigen Zeile ist eine alphanumerische 16 Segment Anzeige Textanzeige Hier werden haupts chlich Ka nalnamen Men punkte eingeblendet In der unteren 7 Segment Anzeige werden Kanalwerte und Einstell parameter angezeigt Temperaturen und Temperaturdifferenzen werden mit Angabe der Einheit C oder K angezeigt 2 Bedienung und Funktion 2 2 2 Symbolleiste symbol normai blinkend te g A bs Relais 1 aktiv ya Speichermaximalbegren zungen aktiv Speicherma Kollektork hlfunktion aktiv ximal R ckk hlfunktion aktiv temperatur berschritten nur Symbolleiste Kollektorminimalbegren Option Frostschutz aktiviert zung aktiv Die Zusatzsymbole der Symbolleiste zeigen den Frostschutziunktion aktiv aktuellen Systemstatus an Kollektornotabschaltung aktiv oder Speichernotab Schaltung Sensordefekt Handbetri
16. den nur bei angschlossenen Tempera turf hlern angezeigt eingeblendet anal Bezeichnung seite irl o Temperatur r ckauff ner 12 Kom w rmemenge rum a an o w rmemenge mm a Entsprechender Kanal ist nur bei aktivierter Option Warmemengenzahlung OWMZ vorhanden Entsprechender Kanal ist nur bei deaktivierter Option Warmemengenzahlung OWMZ vorhanden MEDT Der Kanal Frostschutzgehalt MED wird nur ein geblendet wenn die Frostschutzart MEDT nicht Was ser oder Tyfocor LS G LS MEDT 0 oder 3 ist Kanal Bezeichnung seite Option Kollektork hlung Kollektor Maximaltemperatur Kollektor OKN X Option Minimalbegrenzung 16 Kollektor Minimaltemperatur Kollektor Option Frostschutz Kollektor Frostschutztemperatur Kollektor vax o Maximaler omms 1a Meor o Frostscnuare SSCS MED MEDT Frostschutzgehalt za Minimaldrehzahl Relais 1 na Handbetrieb Relais 1 18 Sprache Vers Xxx versionsnummer OS 12 3 Regelparameter und Anzeigekanale 3 1 1 Anzeige Kollektortemperatur KOL Kollektortemperatur K El Anzeigebereich 9 40 250 C 5 3 1 2 Anzeige Speichertemperaturen TSP Speichertemperaturen ToP Anzeigebereich u 3 gc 40 250 C 3 1 3 Anzeige Sensor 3 und Sensor 4 S3 S4 Sensortemperaturen G Anzeigebereich i 7 Mu 40 250 C L 3 1 4 Uhrzeit JE TI AETI 136 3 1 5 Anzeige sonstiger Temperaturen TRL sonstige Messtemperaturen re Anzeig
17. eb aktiv Ein Einstellkanal wird ge ndert SET Modus 2 Bedienung und Funktion 2 2 3 System Screen Der System Screen aktives Anlagenschema zeigt im Regler ausgew hlte Schemata Es besteht aus meh reren Systemkomponenten Symbolen die je nach Anlagenzustand blinken dauerhaft angezeigt oder 4 IN i Sle i 29 a verborgen werden nur System Screen Anzeige Sensoren Sensor Speicher oben Kollektor 2 Kollektor 1 Pumpen A 4 _ _ Sensor 9 Zusatzsymbol Brennerbetrieb Speicherw rmetauscher Speicher Speicher 2 oder Nachhei zung mit Zusatzsymbol Lo XQ Kollektoren mm Temperatursensor mit Kollektorsensor Speicher Pumpe mit W rmetauscher N N Nachheizung mit Brennersymbol 10 2 Bedienung und Funktion 2 3 Blinkcodes 2 3 1 System Screen Blinkcodes 2 3 2 LED Blinkcodes e Pumpen blinken w hrend der Einschaltphase e Sensoren blinken wenn im Display der zugeh rige Sensor Anzeigekanal ausgew hlt ist e Sensoren blinken schnell bei Sensordefekt e Brennersymbol blinkt wenn Nachheizung aktiv Gr n konstant alles in Ordnung Rot Gr n blinkend Initialisierungsphase Handbetrieb Rot blinkend Sensor defekt Sensorsymbol blinkt schnell 11 3 Regelparameter und Anzeigekanale 3 1 Kanal Ubersicht Legende Entsprechender Kanal ist vorhanden Entsprechender Kanal ist vorhanden wenn die zuge h rige Option aktiviert ist Hinweis S3 und S4 wer
18. eb nehmen Dreh zahlreglung muss deak tiviert werden Die Solarkreispumpe l uft nicht oowonl der Kollektor deutlich w rmer als der Speicher ist Leuchten der Kontroll LED am Regler Springt Pumpe im Hand betrieb an Wird der Pumpenstrom vom Regler freigege ben Sicherungen am Regler 0 K Sicherung austauscnen kein Strom vorhanden Sicherungen prufen austauschen und Stromzuf hrung uber prufen eingestellte Tempera turdifferenz zum Ein schalten der Pumpe zu hoch auf sinnvollen Wert einstellen Pumpe sitzt fest Pumpenwelle mit Schraubendreher in Gang setzen danach gangbar Pumpe defekt austau schen Regler defekt austau schen 5 Zubehor Sensoren Unser Angebot umfasst Hochtemperaturf hler Flach anlegef hler Au entemperaturf hler Raumtempera turf hler Rohranlegef hler und Einstrahlungssensoren auch als Komplettf hler mit Tauchh lse FlowMeter Wenn sie eine W rmemengenbilanzierung realisieren m chten ben tigen sie ein FlowMeter zur Messung des Volumenstromes in ihrem System berspannungsschutz Der berspannungsschutz SP1 sollte grunds tzlich zum Schutz der empfindlichen Temperatursensoren im oder am Kollektor gegen fremdinduzierte Uberspannungen ortsnahe Blitzeinschl ge etc eingesetzt werden Smart Display SD3 Das Smart Display SD3 ist f r den einfachen Anschluss an Regler uber den VBus konzipiert Es dient der V
19. ebereich r ac 40 250 C 56 i Zeigt die momentane Kollektortemperatur an e KOL Kollektortemperatur Zeigt die momentane Speichertemperatur an e TSP Speichertemperatur Zeigt die momentane Temperatur des jeweiligen Zusatz sensors ohne Regelfunktion an e S3 Temperatur Sensor 3 e SA Temperatur Sensor 4 Hinweis S3 und S4 werden nur bei angeschlossenen Tempera tur f hlern angezeigt eingeblendet Hier wird die aktuelle Uhrzeit angezeigt Durch Dr cken der E3 Taste f r 2 Sekunden werden die Stunden durch erneutes Dr cken die Minuten blin kend dargestellt Die Zeit kann mit den Tasten 1 und 2 eingestellt und durch abschliessendes Dr cken der Taste gespeichert werden Zeigt die momentane Temperatur des Sensors an e TRL Temperatur R cklauf 13 3 Regelparameter und Anzeigekanale 3 1 6 Anzeige momentane Pumpendrehzahl n momentane N iv Pumpendrehzahl wer Anzeigebereich 30 100 wu 3 1 7 Betriebsstundenz hler h P Betriebsstundenz hler H pa Anzeigekanal 3 ae us Zeigt die momentane Drehzahl der jeweiligen Pumpe an e n momentane Pumpendrehzanhl 1 Pumpen System Der Betriebsstundenz hler summiert die solaren Be triebsstunden des jeweiligen Relais h P Im Display werden volle Stunden angezeigt Die aufsummierten Betriebsstunden k nnen zur ck gesetzt werden Sobald ein Betriebsstundenkanal angew hlt ist erscheint im Display dauerhaft das Sym bol Die Taste SE
20. een 4 1 2 Elektrischer Anschluss 5 1 2 1 Datenkommunikation BUS ee 6 1 2 2 KlemmenbelegungAnlage 1 6 2 Bedienung und Funktion 7 yd EI ee sn 7 2 2 System Monitoring Display cecen 7 2 2 1 Kanalanzeige ce ccceccceseccessseesensneeeenneeeenees 7 222 Oele ee 8 DPB SV SECM IO CI CSI ee nee 9 2 3 Blinkcodes wooo eee ecceeeecceeeseeeeeeeseeeeeeenees 10 2 3 1 System Screen BlinKcodes 10 232 LED BI COC este 10 3 Regelparameter und Anzeigekanale 11 3 1 Kanal bersicht eeeeeee 11 3 1 1 Anzeige Kan le ccc cccsseeseseeeseseeesessseeeeees 12 3 1 8 Einstell Kandle oo cece sscesseesssessseeeneeseees 14 4 Tipps zur Fehlersuche ccccessseeeee 19 A 1 Verschiedenes 20 S UNDO NOE orisa tants 23 IMPFESSUM ee seen 24 Lieferumfang 1 x Deltasol BS 1 x Zubeh rbeutel 1 x Ersatzsicherung T4A 2 x Schraube und Dubel 4 x Zugentlastung und Schrauben Zus tzlich im Komplettpaket 1 x Sensor FKP6 2 X Sensor FRP6 Technische Daten und Funktionsubersicht e System Monitoring Display e bis zu 4 Temperatursensoren Pt1000 e Warmebilanzierung e VBus e Funktionskontrolle e Bedienerfreundlich durch einfache Handhabung e montagefreundliches Geh use in herausragendem Design e Drehzahlregelung und solarer Betriebsstundenz hler
21. emperature sensors Pt1000 Outputs 1 semiconductor relay and 1 standard relay Bus VBus Power supply 220 240 V Mode of operation Type 1 y Switching capacity semiconductor relay 1 1 A 220 240 V electromechanical relay 2 1 A 220 240 V ce 30 1 Installation Examples Deltasol BS Standard solar systems 1 1 Mounting display front cover push button cable gland with strain relief fuse 4A fastening fastening For detailed connection diagrams see chapter 1 WARNING Always switch off power supply and disconnect the controller from the mains before opening the housing The unit must only be located in dry interior locations It is not suitable for installation in hazardous locations and should not be placed close to any electromagnetic fields The controller must additionally be supplied from a double pole switch with contact gap of at least 3 mm Please pay attention to separate routing of sensor cables and mains cables 1 Unscrew the cross head screw from the cover and remove it along with the cover from the housing 2 Mark the upper fastening point on the wall and drill and fasten the enclosed wall plug and screw leaving the head protruding 3 Hang the housing from the upper fastening point and mark the lower fastening point throu
22. en Sie in Kapitel 1 Achtung Vor jedem ffnen des Geh uses all polige Trennung von der Netzspan nung sicherstellen Die Montage darf ausschlie lich in trockenen Innen raumen erfolgen Beachten Sie dass das Ger t f r eine einwandfreie Funktion an dem ausgew hlten Ort keinen starken elektromagnetischen Feldern ausge setzt sein darf Der Regler muss uber eine zus tzliche Einrichtung mit einer Trennstrecke von mindestens 3 mm allpolig bzw mittels einer Trennvorrichtung Si cherung nach den geltenden Installationsregeln vom Netz getrennt werden k nnen Bei der Installation der Netzanschlussleitung und der Sensorleitungen auf getrennte Verlegung achten 1 Kreuzschlitzschraube in der Blende herausdrehen und Blende nach unten vom Geh use abziehen 2 Aufh ngung auf dem Untergrund markieren und beiliegenden D bel mit zugeh riger Schraube vor montieren 3 Geh use am Aufh ngungspunkt einh ngen Befesti gung auf dem Untergrund markieren Lochabstand 130 mm anschlie end unteren D bel setzen A Geh use oben einh ngen und mit unterer Befesti gungsschraube fixieren 1 Installation 1 2 Elektrischer Anschluss Sicherung Temp Sensor Pt1000 S1 S2 S3 112 3 4 51 6 7 81 9 10 elolelelalelaielele nl DD R1 1 1 A 220 240 V C li E ne R1 VI2 1 A 220 240 V aL Sensorklemmen VBus Anschlussklemmen Verbraucherklemmen Erdungsklemmen Netzklemmen
23. g einschlie lich aller seiner Teile ist urheberrechtlich gesch tzt Eine Verwendung au erhalb des Urheberrechts bedarf der Zustimmung der Firma COSMO GmbH Dies gilt insbesondere f r Vervielf ltigungen Kopien berset zungen Mikroverfilmungen und die Einspeicherung in elektronischen Systemen Herausgeber COSMO GmbH Brandst cken 31 22549 Hamburg Irrtum und technische nderungen vorbehalten Notizen 25 COSMO GUTES KLIMA BESSER LEBEN Deltasol BS Assembly and Operating Constructions 28 Safety advice Safety advice Please pay attention to the following safety advice in order to avoid danger and damage to people and property Instructions Attention should be paid to valid local regulations the statutory provisions for prevention of industrial accidents the statutory provisions for environmental protection the Health and Safety at Work Act 1974 Part P of the Building Regulations 2005 BS7671 Requirements for electrical installations and relevant safety regulations of DIN EN DVGW TRGI TRF and VDE These instructions are exclusively addressed to autho rised skilled personnel Only qualified electricians should carry out installation and maintenance work Initial installation should be carried out by named qualified personnel Appropriate usage This product is to be used in solar thermal systems in compliance with the technical data specified in these instructi
24. gh the hole in the terminal box centres 130 mm Drill and insert the lower wall plug 4 Fasten the housing to the wall with lower fastening screw and tighten 1 Installation 1 2 Electrical connection fuse Temp Sensor Pt1000 S2 1 2 3 4 5 6 7 18s 910 ojojojojojojojojojo lt L A NA R1 1 1 A 220 240 V C i E ma R1 VI2 1 A 220 240 V 4 sensor terminals ground terminals load terminals VBus mains terminals connection clamps 31 The power supply to the controller must be carried out via an external power switch last step and the supply voltage must be 220 240 V 50 60 HZ Flexible cables must be attached to the housing with the enclosed strain relief and the corresponding screws The controller is equipped with 2 relays to which loads such as pumps valves etc can be connected e Relay 1 18 conductor R1 17 neutral conductor N 13 ground clamp e Relay 2 16 conductor R2 15 neutral conductor N 14 ground clamp Temperature sensors S1 to S4 have to be con nected to the following terminals either polarity 1 2 sensor 1 e g sensor collector 1 3 4 sensor 2 e g sensor store 1 5 6 sensor 3 e g store top sensor 7 8 sensor 4 e g return temperature sensor The power supply connection has to be carried out via the following terminals 19 neutral conductor N 20 conductor L 12 ground clamp 2 Electrostatic discharge can lead
25. in wird Uber das Display des Reglers eine Meldung angezeigt Warnsymbol R1 1 1 A 220 240 V ae C li DO Te 2 1 A 220 240 V ale S2 S4 VBus 1 2 3 4 5 6 7 8 910 Betriebskontrolllampe Betriebskontrolllampe blinkt rot Im Display erscheint das Symbol und das Symbol amp blinkt Betriebskontrolllampe ist dauerhaft erloschen Sensordefekt In entsprechendem Sensor Anzeigekanal wird anstatt einer Temperatur ein Fehlercode angezeigt Leitungsbruch Kurzschluss Leitung pr fen Leitung pr fen Abgeklemmte Pt1000 Temperatursen soren k nnen mit einem Widerstands Messger t berpr ft werden und haben bei den entsprechenden Temperaturen die untenstehenden Widerstandswerte 0 10001 100 1385 Widerstandswerte der Pt1000 Sensoren EB N UJ N O 00 NIN IO Ul Ul U1 JO jo n a a joa faa UY U GJ U U IN IN IN 0 A A IN O 180 IN U ON IN 0 80 O jn Bei erloschener Betriebs Kontrolllampe ist die Stromversorgung des Reglers zu kontrollieren Die Topfsicherung des Reglers ist de fekt Diese wird nach Abnahme der Blende zug nglich und kann dann ausgetauscht werden Ersatzsicherung liegt In einem Zubeh rbeutel bei 20 4 Tipps zur Fehlersuche 4 1 Verschiedenes Pumpe l uft hei jedoch kein W rmetransport vom Kollektor zum Speicher Vor und R cklauf gleich warm evtl auch Blubbern in der Leitung Luft im System System en
26. in non return valve or an electric 2 port val ve behind the circulation pump in pump opera tion the 2 port valve is open otherwise It is closed conect pump and 2 port valve in par allel activate circulation again 45 Use the circulation pump with timer and switch off thermo Stat energy efficient circulation Check whether the pumps of the after heating circuit runs at night check non return valve problem solved Further pumps which are connected to the solar store must also be che cked Clean or replace 46 4 Troubleshooting The solar circuit pump does not run although the coll ector is significantly warmer than the store Does the control LED flash ef Does the pump start up in manual operation e TL Is the pump current released by the con troller Are the controller fuses 0 k reek Replace the fuses No current check fuses replace them and check power supply The adjusted tempe rature difference for starting the pump is to high choose a va lue which makes more SENG Is the pump stuck yes Turn the pump shaft using a screwdriver now passable Pump is defective re place it Controller might be de fective replace it 5 Accessory Sensors Our product range includes high precision platin tem perature sensors flatscrew sensors outdoor tempera ture sensors indoor temperature sensors cylindrical cl
27. ion occurs a message Is displayed in the display of the controller Warning symbol Operating control lamp Operating control lamp off Check the power supply The fuse of the controller could be blown It can be replaced after the front cover has been removed Spare fuse IS enclosed in the accessory bag 44 4 Troubleshooting 4 1 Various Pump is overheated but no heat transfer from the colle ctor to the store flow and return have the same tempe rature perhaps also bubble in the lines Air in the system Vent the system in crease system pressure to at least static primary pressure plus 0 5 bar If necessary Increase the pressure switch the pump on and off for a Short time Is the collector circuit blocked at the dirt trap Clean the dirt trap Pump starts up very late Switch on temperature difference ATon too large Change ATon and AToff correspondingly Non ideal position of colle ctor sensor e g flatscrew sensor instead of sensor in immersion sleeves Activate tube collector function if necessary Pump starts for a short moment switches on oft again etc Is the temperature dif ference at the control ler too small Change ATon and AToff correspondingly Mount the collector sensor at solar flow warmest collector out put use the immersion Sleeve of the respective collector Wrong position of the collector sensor Pla
28. ip on sensors and irradiation sensors also aS com plete sensors with immersion sleeve Flowmeter IF you wish to carry out a heat quantity measurement you need a flowmeter for measuring the flow rate in your system Overvoltage protection device In order to avoid overvoltage damage at collector sen sors e g caused by local lightning storms we recom mend in stalling the overvoltage protection SP1 Smart Display SD3 The Smart Display SD3 is designed for simple connec tion to controllers via the VBus for visualisation of the data Issued by the controller collector and store tem peratures as well as energy yield of the solar system The use of high efficient LEDs and filter glass assures a high optical brilliance and good readability even in poor visibility conditions and at a larger distance An additional power supply is not required 47 48 Imprint Important notice We took a lot of care with the texts and drawings of this manual and to the best of our knowledge and consent As faults can never be excluded please note Your own calculations and plans under consideration of the current standards and DIN directions should only be basis for your projects We dont offer a gua rantee for the completeness of the drawings and texts of this manual they only represent some examples They can only be used at your own risk No liability is assumed for incorrect incomplete or false information and or any
29. isu alisierung der vom Regler ausgegebenen Kollektor und Speichertemperatur sowie des Energieertrages der Solaranlage Der Einsatz von hocheffizienten LEDs und Filterglas erzeugt eine hohe optische Brillanz und gute Lesbarkeit auch bei schlechten Lichtverh ltnissen und aus gr erer Distanz Eine zus tzliche Spannungsver sorgung ist nicht erforderlich 23 24 Impressum Wichtiger Hinweis Die Texte und Zeichnungen dieser Anleitung entstanden mit gr tm glicher Sorgfalt und nach bestem Wissen Da Fehler nie auszuschlie en sind m chten wir auf folgendes hinweisen Grundlage Ihrer Projekte sollten ausschlie lich eigene Berechnungen und Planungen an Hand der jeweiligen g ltigen Normen und DIN Vorschriften sein Wir schlie Ben jegliche Gew hr f r die Vollst ndigkeit aller in die ser Anleitung ver ffentlichten Zeichnungen und Texte aus sie haben lediglich Beispielcharakter Werden darin vermittelte Inhalte benutzt oder angewendet so geschieht dies ausdr cklich auf das eigene Risiko des jeweiligen Anwenders Eine Haftung des Herausgebers f r unsachgem e unvollst ndige oder falsche Anga ben und alle daraus eventuell entstehenden Sch den wird grunds tzlich ausgeschlossen Anmerkungen Das Design und die Spezifikationen k nnen ohne Vo rank ndigung ge ndert werden Die Abbildungen k nnen sich geringf gig vom Produk tionsmodell unterscheiden Impressum Diese Montage und Bedienungsanleitun
30. lector emergency EN shutdown temperature Adjustment range 110 200 C Factory setting 140 C 3 1 12 System cooling OCX System cooling option feline Adjustment range OFF ON 1 Factory setting OFF CMX Collector maximum temp rn Adjustment range 100 190 C Factory setting 120 C If OREC is additionally enabled 3 1 13 Minimum collector function OCN Mimimum collector function FINI Adjustment range OFF ON Factory setting OFF CMN Minimum collector MNI temperature Adjustment range 10 90 C Factory setting 10 C temperature EM is exceeded the controller will switch off the solar pump R1 in order to protect the system against overheating collector emergency shutdown The factoring setting is 140 C but it can be changed within the adjustment range of 110 200 C A flashing is displayed When the adjusted maximum store temperature is reached the system stagnates If the collector tempe rature increases to the adjusted maximum collector temperature CMX the solar pump is activated until the collector temperature falls below the maximum collector temperature The store temperature may increase subordinate active maximum store tempe rature but only up to 95 C emergency shutdown of the store If the store temperature is higher than the maximum store temperature S MX and if the collector tempe rature is at least 5 K below the store temperature the solar
31. llektor und die Rohrleitungen wieder unter die eingestellte Speichermaximaltemperatur S MX zu r ckgek hlt wurde Bei aktiver Systemk hlung wird im Display blinkend angezeigt Durch die K hlfunktion bleibt die Solaranlage an hei en Sommertagen l nger betriebsbereit und sorgt f r eine thermische Entlastung des Kollektor feldes und des W rmetr germediums Die Kollektor Minimaltemperatur ist eine Mindest Ein schalttemperatur die Uberschritten werden muss damit die Solarpumpe R1 eingeschaltet wird Die Mindesttem peratur soll ein zu h ufiges Einschalten der Solarpumpe bei geringen Kollektor Temperaturen verhindern Bei unterschrittener Minimaltemperatur wird im Display amp blinkend angezeigt 17 3 Regelparameter und Anzeigekanale 3 1 14 Option Frostschutzfunktion OKF Frostschutzfunktion ial i Einstellbereich OFF ON Bone a Fa Werkseinstellung OFF wee KFR x Frostschutztemperatur Einstellbereich 10 10 C K F fr Werkseinstellung 4 0 C u 3 1 15 R ckk hlfunktion ORUE Option Ruckkuhlung ICI IE Einstellbereich OFF ON URL race Werkseinstellung OFF uri 3 1 16 R hrenkollektorfunktion ORK R hrenkollektorfunktion n rar Einstellbereich OFF ON eee mee Werkseinstellung OFF wr Die Frostschutzfunktion setzt bel Unterschreiten der eingestellten Frostschutztemperatur den Ladekreis zwi schen Kollektor und dem Speicher in Betrieb um das Medium vor dem einfrieren oder ei
32. ndicken zu sch t zen Bei berschreiten der eingestellten Frostschutz temperatur um 1 C wird der Ladekreis ausgeschaltet Hinweis Da f r diese Funktion nur die begrenzte W rmemenge des Speichers zu Verf gung steht sollte die Frost schutzfunktion nur in Gebieten angewandt werden in denen an nur wenigen Tagen im Jahr Temperaturen um den Gefrierpunkt erreicht werden Bei Erreichen der eingestellten Speichermaximaltempe ratur SMAX bleibt die Solarpumpe eingeschaltet um eine berhitzung des Kollektors zu verhindern Dabei kann die Speichertemperatur weiter ansteigen jedoch nur bis 95 C Speichersicherheitsabschaltung Sobald wie m glich witterungsbedingt wird die Solar pumpe eingeschaltet bis der Speicher uber den Kollek tor und die Rohrleitungen wieder auf seine eingestellte Speichermaximaltemperatur zur ckgek hlt wurde Stellt der Regler einen Anstieg um 2 K gegen ber der zuletzt gespeicherten Kollektortemperatur fest so wird die Solarpumpe fur 30 Sekunden auf 100 eingeschal tet um die aktuelle Mediumtemperatur zu erfassen Nach Ablauf der Solarpumpenlaufzeit wird die aktuelle Kollektortemperatur als neuer Bezugspunkt gespei chert Wenn die erfasste Temperatur neuer Bezugs punkt wieder um 2 K berschritten wird so schaltet sich die Solarpumpe wieder f r 30 Sekunden ein Sollte w hrend der Laufzeit der Solarpumpe oder auch des Anlagenstillstandes die Einschaltdifferenz zwischen Kollektor und Speiche
33. ng codes green everything OK red green flashing initialisation phase manual operation red flashing sensor fault Sensor symbol is flashing quickly 36 3 Control parameters and display channels 3 1 Overview of channels Legend Corresponding channel is available Corresponding channel is available when the corre sponding option is enabled Please note Only if temperature sensors are connected will S3 and S4 be displayed channel description page Re Temperature retum sensor a7 om o regeny ae mm Heat quantity wh ae Switch on temperature Switch off temperature Only if the option heat quantity measurement Is ac tivated OHQM will the corresponding channel be available Only if the option heat quantity measurement is de activated OHQM will the corresponding channel be available MEDT Only if an antifreeze MEDT other than water or Tyfo cor LS G LS MEDT 0 or 3 is used will the channel antifreeze concentration MED be displayed channel description page Option collector cooling collector Maximum temperature collector Option minimum limitation collector Minimun temperature collector Option antifreeze collector Antifreeze temperature collector Emax o mamm owas e meor aneen Te pesa rooc version unbe 37 3 Control parameters and display channels 3 1 1 Collector temperature COL Collector temperature display range 40 250 C
34. nst freezing or coagulating If the adjusted antifreeze temperature Is exceeded by 1 C the loading circuit will be deactivated Please note Since this function uses the limited heat quantity of the store the antifreeze function should be used in regions with few days of temperatures around the freezing point If the adjusted maximum store temperature S MX is reached the controller keeps the solar pump running in order to prevent the collector from being overheated The store temperature may increase but only up to 95 C emergency shutdown of the store The solar pump is switched on once the collector temperature is lower than the store temperature It is Switched off when the store is cooled down to the adjusted maximum temperature via the collector and the pipework If the controller detects an increase in collector temperature by 2 K compared to the previously stored collector temperature the solar pump will be switched on at 100 for about 30 seconds in order to detect the fluid temperature The current collector temperature will be saved as a new reference value If the measured temperature new reference value is exceeded by 2 K the solar pump will run for 30 seconds If the switch on difference between the collector and the store is exceeded during the runtime of the solar pump or the standstill of the system the controller will automatically switch to solar loading If the collector temperature deacreases by 2 K d
35. nstellbereich 2 95 C Bi Werkseinstellung 60 C Zun chst verh lt sich die Regelung wie eine Standard differenzregelung Bei Erreichen der Einschaltdifferenz DTE wird die Pumpe eingeschaltet und nach dem Los rei impuls 10 s mit der Minimaldrehzahl NMN 30 gefahren Erreicht die Temperaturdifferenz den eingestellten Sollwert DT S so wird die Drehzahl um eine Stufe 10 erh ht Bei einem Anstieg der Diffe renz um 2 K ANS wird die Drehzahl um jeweils 10 angehoben bis zum Maximum von 100 Mit Hilfe des Parameters Anstieg l sst sich das Regelverhalten an passen Bei Unterschreiten der eingestellten Ausschalt Temperaturdifferenz DT A schaltet der Regler AUS 10 sek lang 100 Drehzahl Bei berschreiten der eingestellten Maximaltempera tur wird eine weitere Speicherladung verhindert und somit eine sch digende berhitzung vermieden Bei berschrittener Speicher Maximaltemperatur wird im Display angezeigt Hinweis Der Regler verf gt Uber eine Speichersicher heitsabschaltung die bei 95 C f r die Speicher temperatur eine weitere Beladung verhindert 16 3 Regelparameter und Anzeigekanale 3 1 11 Kollektor Grenztemperatur Kollektornotabschaltung NOT Kollektorbegrenzungs temperatur NIT Einstellbereich 110 200 C N Ea Werkseinstellung 140 C ioe TE i 3 1 12 Systemk hlung OKX Option Systemk hlung mv Einstellbereich OFF ON Ln A Werkseinstellung OFF PRE KMX K
36. nzeichneten Klemmen Uber diesen Daten Bus k nnen ein oder mehrere VBus Module angeschlossen werden z B e Gro anzeigen GA3 SD3 e Datenlogger DL2 e Datenfernanzeige Ausserdem l sst sich der Regler mit Hilfe des RS COM Adapters an einen PC anschliessen Mit der Service Center Software RSC k nnen Reglerparameter ge n dert sowie Reglermesswerte ausgelesen verarbeitet und visualisiert werden Die Software erm glicht eine komfortable Funktionskontrolle und Einstellung des Systems Standard Solarsystem mit 1 Speicher 1 Pumpe und 3 Sensoren Der Sensor S4 TRL kann optional zur Warmemengenbilanzierung verwendet werden Optional bei Verwendung eines elektrischen Ventils anstelle eines R ckfluss verhinderer Symbol Beschreibung Kollektorsensor 53 Speichersensor oben optional S4 TRL Sensor f r W rmemengenz hlung optional Solaroumpe Ventil optional 2 Bedienung und Funktion 2 1 Einstelltaster R ckw rts Vorw rts SEI Auswahl Einstellmodus 2 2 System Monitoring Display To BRENZ ZEE ER 00 0 mc III K Vollanzeige Monitoring Display 2 2 1 Kanalanzeige nur Kanalanzeige Der Regler wird ber die 3 Drucktaster unter dem Display bedient Taster 1 dient dem Vorwarts Scrollen durch das Anzeigemenu oder dem Erh hen von Ein stellwerten Taster 2 wird entsprechend f r die umge kehrte Funktion benutzt Zur Einstellung nach letztem Anzeigekanal die Taste 1 ca 3 Sekun
37. ollektormaximaltemperatur KMX Einstellbereich 100 190 C A Fe Werkseinstellung 120 C IZ Bei zus tzlich aktivierter Option ORUE 3 1 13 Option Kollektorminimalbegrenzung OKN Kollektorminimalbegrenzung FKN Einstellbereich OFF ON ae c aa Werkseinstellung OFF wr KMN Kollektorminimal Ang temperatur IN ss o cG Einstellbereich 10 90 C OL Werkseinstellung 10 C Bei berschreiten der eingestellten Kollektor Grenztem peratur NOT wird die Solarpumpe R1 ausgeschaltet um einer sch digenden berhitzung der Solar Kom ponenten vorzubeugen Kollektornotabschaltung Ab Werk ist die Grenztemperatur auf 140 C eingestellt kann aber in dem Bereich von 110 200 C verandert werden Bei uberschrittener Kollektor Grenztemperatur wird im Display A blinkend angezeigt Bei Erreichen der eingestellten Speichermaximaltem peratur schaltet die Solaranlage ab Steigt jetzt die Kollektortemperatur auf die eingestellte Kollektorma ximaltemperatur KMX an wird die Solarpumpe so lange aktiviert bis dieser Temperaturgrenzwert wieder unterschritten wird Dabei kann die Speichertemperatur weiter ansteigen nachrangig aktive Speichermaximal temperatur jedoch nur bis 95 C Speichersicherheits abschaltung Liegt die Speichertemperatur ber der Speicherma ximaltemperatur S MX und die Kollektortemperatur mindestens 5K unter der Speichertemperatur l uft die Solaranlage solange weiter bis der Speicher ber den Ko
38. ons Improper use excludes all liability claims Subject to change without prior notice Errors excepted Declaration of conformity The product complies with the relevant di rectives and is therefore labelled with the CE mark The Declaration of Conformity is available upon request please contact the manufacturer Table of contents Safety instructions ccccceseseeeeeeeeeeeeeeneees 28 Technichal data and overview of functions 29 1 NStallaloN anne nungen 30 1 1 NOLTE este 30 1 2 Electrical Wiring eccerre 31 1 2 1 Data communication Bus 32 1 2 2 Standard solar system cccceseee 32 2 Operation and function u 22202220 33 2 1 Buttons for adjustment 33 22 System monitoring display 30 221 CMERMC GSO y enana 33 222 FOD nee eine 34 2 2 3 SYSTEM SCEN 35 2 Fasain COES semasa 39 2 3 1 System Screen flashing codes 35 232 LED TIASMING C0488 en ao 3 Control parameter and display channels 36 3 IVO eine 36 31 6 Display channe lS ee 3 3 1 7 20 Adjustment channels 38 4 Troubleshooting cccecceeeeeeeeeeeeeeeeeees 43 4 1 VA OU een 44 5 ACCOSSONY iii ccscccndecctscuceannevesveusecaunsaeawesanecones 47 DINE eines eee nr rs ren een ee 48 Scope of delivery 1 x Deltasol BS 1 x accessory bag 1 x fuse T4A 2 x screws and dowels 4 x strain relief and screws Additionally enclosed in the full kit 1
39. r berschritten werden so scnal tet der Regler automatisch in die Solarbeladung um Wenn die Kollektortemperatur w hrend des Stillstandes um 2 K absinkt so wird der Einschaltpunkt f r die Ron renkollektorfunktion neu errechnet 18 3 Regelparameter und Anzeigekanale 3 1 18 Drehzahlregelung nMN Drehzahlregelung Einstellbereich 30 100 m Werkseinstellung 30 30 MNI UN 55 3 1 19 Betriebsartenmodus HND Betriebsartenmodus HNI Einstellbereich L OFF AUTO ON Auko Werkseinstellung AUTO 3 1 20 Sprache SPR SPR Spracheinstellung fade Einstellbereich ar dE En It Fr JE Werkseinstellung dE Mit dem Einstellkanal nMN wird f r den Ausgang R1 eine relative Mindestdrehzahl f r die angeschlossene Pumpe vorgegeben ACHTUNG Bei Verwendung von nicht drehzahlgeregelten Verbrauchern z B Ventilen muss der Wert auf 100 eingestellt werden um die Drehzahlrege lung zu deaktivieren F r Kontroll und Servicearbeiten kann der Betriebs artenmodus des Reglers manuell eingestellt werden Dazu wird der Einstellwert HND angew hlt der fol gende Eingaben zul sst e HND Betriebsartenmodus OFF Relais aus blinkend F AUTO Relais im automatischen Regelbetrieb ON i Relais ein N blinkend F In diesem Kanal wird die Menusprache eingestellt e dE Deutsch e En Englisch e It Italienisch e Fr Franz sisch 19 4 Tipps zur Fehlersuche Topfsicherung T4A Tritt ein Storfall e
40. system remains activated until the store is cooled down below the adjusted maximum temperature S MX via the collector and the pipework If the system cooling function is enabled flashing is shown on the display Due to the cooling function the system will have a longer operation time on hot sum mer days and guarantees thermal relief of the collector field and the heat transfer fluid The minimum collector temperature is the minimum temperature which must be exceeded for the solar pump R1 to switch on The minimum temperature prevents the pump from being switched on too often at low collector temperatures If the temperature falls below the minimum temperature amp flashing is shown on the display 41 3 Control parameters and display channels 3 1 14 Antifreeze function OCF Antifreeze function E Adjustment range a ce OFF ON urr Factory setting OFF CFR Eg Antifreeze temperature f R Adjustment range C 10 10 C 4 Factory setting 4 0 C 3 1 15 Recooling function OREC recooling function option reac Adjustment range UN EL om OFF ON geer Factory setting OFF 3 1 16 Tube collector function O TC Tube collector function ETE Adjustment range a OFF ON wii ds Factory setting OFF The antifreeze function activates the loading circuit bet ween the collector and the store when the temperature falls below the adjusted antifreeze temperature This will protect the fluid agai
41. tl ften Sy stemdruck mind auf Statischen Vordruck plus 0 5 bar bringen evtl Druck weiter er h hen Pumpe kurz an und ausschalten Ist der Kollektorkreis am Schmutzf nger verstopft Schmutzf nger reinigen Pumpe wird vermeintlich sp t eingeschaltet Einschalt Temperatur differenz ATein zu gro gew hlt ATein und ATaus ent sprechend ndern Kollektorf hler ung nstig positioniert z B Anlege fuhler statt Tauchtuhler Gegebenenfalls Roh renkollektorfunktion aktivieren Pumpe l uft kurz an schaltet ab schaltet wieder an USW Reglerflattern Temperaturdifferenz am Regler zu klein ATein und ATaus ent sprechend ndern Kollektorsensor am Solarvorlauf w rmster Kollektorausgang plat zieren Tauchh lse des entspr Kollektors nut zen Kollektorsensor falsch platziert Plausibilit tskontrolle der Optionen Rohren kollektorfunktion 4 Tipps zur Fehlersuche Die Temperaturdifferenz zwischen Speicher und Kollektor wird w hrend des Betriebes sehr gro der Kollektorkreis kann die W rme nicht abf hren Kollektorkreis Pumpe defekt Pr fen Tauschen W rmetauscher verkalkt Entkalken W rmetauscher verstopft Sp len W rmetauscher zu klein Neuberechnung der Dimensionierung 21 Speicher k hlen ber Nacht aus Kollektorkreispumpe lauft nachts Reglerfunktion pr fen R
42. to damage to electronic components AN Dangerous voltage 32 1 Installation 1 2 1 Data communication Bus The controller comes with a VBus for data commu nication and energy supply of external modules The connection is effected with optional polarity at the clamps marked with VBus Via this data Bus you can install one or more VBus modules e g Pt1000 e large display GA3 SD3 e Data logger DL2 e Data teleindication R1 1 1 A 220 240 V Temp sensor R1 V 2 1 A 220 240 V VBus Additionaly the controller can be connected to the PC connection clamps with the help of a RS COM adapter With the Service Center Software RSC the controller parameters can be changed measurements can be read out Processed and visualised The software enables an easy function control and adjustment of the system 1 2 2 Allocation of terminals for system 1 Standard solar system with 1 store 1 pump and 3 sensors The sensor S4 TR can be optionally used for heat quantity measurement q1 1 S3 S4 VBus N RI VIN RIIN L 51617 819110 12 13 14 15 16 17 18 19 20 oi Symbol Specification ss collector sensor store base sensor a S9 store top sensor lt 2 optional sensor for heat quantity measurement optional 2 Operation and function 2 1 Buttons for adjustment backwards forward SET selection adjustment mode 2 2 System monitoring display Gia a fr a 71 0 am C aan
43. uring standstill the switch on value for the tube collector function will be recalculated 42 3 Control parameters and display channels 3 1 19 Operating mode HND Operating mode Adjustment range OFF AUTO ON Factory setting AUTO 3 1 20 Language LANG Language choice Adjustment range dE Ef It Fr Factory setting En L F 1NG En For control and service work the operating mode of the controller can be manually adjusted For this purpose select the adjustment value HND The following adjust ments can be carried out e HND Operating mode OFF relay off N flashing 2 AUTO relay in automatic operation ON relay on Z flashing 9 In this channel different languages are available dE German En English It Italiano Fr French 4 Troubleshooting R1 1 1 A 220 240 V Temp Sensor R1 V 2 1 A 220 240 V Pt1000 Operating control lamp flashes red The symbol and the Aare shown Sensor fault An error code instead of a temperature is shown on the sensor display channel 888 8 88 8 Cable is broken Short circuit Check the cable Check the cable Disconnected Pt1000 temperature sensors can be checked with an ohmmeter In the following table the resistance values corresponding to different temperatures are listed 60 1232 0 1000 80 1309 90 1347 Resistance values of the Pt1000 sensors 43 IF a malfunct
44. usibility control of the tube collector function The temperature difference between the store and the collector increases enormously during operation the collector circuit cannot divert the heat Collector circuit pump defective Check replace it Heat exchanger calci fied Fleer Decalify it Heat exchanger blo cked 4 Troubleshooting Repalce with correctly sized one Heat exchanger too small yes Stores cool down at night Does the collector circuit pump run in the night Check controller Check the non return valve in flow and return pipe with regard to the functional efficiency Increase insulation Replace insulation or increase It Insulate the connections At night the collector temperature is higher than the outdoor tem perature Sufficient store insula tion m Insulation close enough to the store m Are the store connec tions insulated Warm water flow up wards reek Change connection and let the water flow side wards or through a si phon bow downwards less store losses now Does warm water cir culation run for a very long time Circulation pump and blocking valve should be switched off for 1 night less store losses Check the non return valve in warm water cir culation o k The gravity circulation in the circulation line is too strong insert a stronger valve
Download Pdf Manuals
Related Search
Related Contents
Samsung GT-E1202I دليل المستخدم Samsung SCH-I539 用户手册 Maschine Mikro Manual German Instruction Manual VIMEK 404 T4 ML・ー00 明 Origin Storage Internal Notebook Keyboard - Belgian Articulo 4 - Evaluacion producción y calidad 2009 - Austin Al-Anon TD S H ー BA 東芝f頃斜天井ヌ寸応多丈T用ハンガ「取扱説明書 Copyright © All rights reserved.