Home
Samsung AQ18VWAN دليل المستخدم
Contents
1. Room Temperature sensor Power On Off button Airflow blade outlet Air filter under the panel mpizone mode indicator mpizone Auto cleaning indicator Timer good slee p E mode indicator Set temperature amp Operation indicator room temperature Auto Cool Dry Fan Heat SAMSUNG SS Le SS lt AQ VWA Series AQ VBA Series AQ VSA Series nit AQO9V Series Air Inlet Rear Air Outlet Connection Valve Inside nit AQ12V Series Air Inlet Rear Air Outlet Connection Valve Inside nit AQ18V Series Air Inlet Rear Connection Valve Inside AQ24V Series Air Inlet Rear Air Outlet Connection Valve Inside Remote Control Buttons and Display gt Airflow direction indicator Temperature setting Operating mode indicator ME Auto Cool Dry Fan Heat mpizone mode indicator f gi ai apid AutoSilenci F mi Turbo function indicator F at 1 Fan speed indicator iE Saver Energy saving indicator Battery life indicator Remote control good sleep mode indicator transmission indicator Off Timer indicator F good i TSleep O CII or rd On Timer indicator D Power On Off button JT j i Temperature adjustment buttons Mode selection but
2. the previous setting You can select the Turbo function in Auto Cool and Heat mode If you select this function in Dry or Fan mode the mode changes to Auto mode Turbo Auto 3 Press the 5 button again to stop the Turbo Function before the end of the 3 N 30 minute period Result The air conditioner is reset automatically to the previous setting EA a J 4 Tocontrol the airflow direction refer to page 20 Selecting the Energy Saving Function You can select the Energy Saving Function to save energy when cooling The temperature range decreases in order to perform this function 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps 2 Press the amp button Result o The indoor unit beeps 4 The air conditioner runs in the Energy saving function The outer airflow blade moves up and down 4 The airflow direction indicator is displayed automatically To stop the Energy saving function press the o again Set Temp Cool J E E Saver Auto L Lic You can select the Energy saving function only in Cool mode 3 Press the QIO button to adjust the temperature until the required temperature is displayed You can set the temperature between 26 C and 30 C If you want to adjust temperature under 26 C cancel the Energy sav
3. For the first 3 5 minutes the fan may not operate to prevent cool air from flowing out of the indoor unit This helps to warm the air in your room sufficiently 5 To control the airflow direction refer to page 20 Selecting Dry Mode Select Dry mode if you want to dehumidify your room You can adjust the temperature in this mode 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps at Mode Fan Speed 2 Press the button on the remote control until Dry is displayed Mode Result The indoor unit beeps each time you press the O button The air conditioner runs in the Dry mode Set Temp You can change modes at any time 3 Press the O button to adjust the temperature until the required temperature is displayed You can set the temperature between 18 C and 30 C Result Each time you press the QIO button Set Temp The temperature adjusts by 1 C TW The indoor unit beeps auto le The air conditioner starts dehumidifying and the fan speed adjusts automatically 4 To control the airflow direction refer to page 20 Selecting Fan Mode the air in your room You can adjust the fan speed in this mode 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts u
4. When the power returns the air conditioner will start up again automatically Protection mechanism When the air conditioner is started immediately after being plugged in or stopped the normal operation starts up after 3 minutes for the reason of protection Solving Common Problems Before contacting the after sales service perform the following simple checks They may save you the time and expense of an unnecessary call Problem Explanation Solution The air conditioner does not Check if power is on and operate the air conditioner again operate at all Check if the circuit breaker is switched off Check if Off Timer is set The temperature is not adjusted Check if you selected the Fan mode The air conditioner does not operate Check if the air conditioner is cooling only model in the HEAT mode Check if the remote control is for cooling only model The cool warm air does not come Check if set temperature higher lower than current temperature out from the air conditioner Check if you selected the Fan mode Select the Cool Heat Auto or Dry mode Check if the air filter is blocked by dirt Clean the air filter regularly Check if the there is cover on the outdoor unit or any obstacle Remove the cover or obstacle Check if you installed the air conditioner under direct sunlight The window or door may be opened Check if you turn on the air conditioner just now It takes abou
5. dispose of the unit consult your dealer If pipes are removed incorrectly refrigerant may blow out and come into contact with your skin causing injury Releasing refrigerant into the atmosphere also damages the environments gt Install the outdoor unit so as tolet the discharged air out properly Avoid a place that may disturb your neighbor by noise gt Please recycle or dispose of the packaging material for this product in an environmentally responsible manner gt Install the drain hose to let the water run safely and correctly CAUTION REGARDING POWER SOURCE mf gt Disconnect the circuit breaker gt Contact the service center or gt Contact the service center when you don t use the manufacturer if you wantto after turning off the air air conditioner for a long time repair the air conditioner conditioner if strange noise to save energy is heard burning smell or 2 smoke blow DURING OPERATION gt Do not open the front grille gt Avoid cold and hot air b Avoid the water from during operation reaching to person petora O getting into the plant directly for a long time air conditioner gt Do not use the air conditioner gt Do not step on the air Donot drink the water from for a long time in a closed room conditioner or put heavy the air conditioner or in a place where ther
6. incorrectly WHEN NSTALLING gt Do not install the unit in a gt Do not connect the ground place where it is exposedto unit where there s the riskof to a gas pipe water pipe inflammable gas leakage dropping such as on high lightningrod or telephone outer wall or outside ofthe earth terrace gt The installation must be carried out by a licensed installer or qualified personnel when installing the unit for the first time or reinstalling it gt Contact the service center if the air conditioner is under water gt Do not pull the electric wire gt Install the switch and circuit gt Use the rated current fuse or touch the power plug with o breaker only for 3 the wet hands air conditioner N N N gt Do not bend the electric wire gt Use the power source with o gt If the power plug is by force or weigh down the separate wiring only for air damaged replace it by the air conditioner not to be out O conditioner o manufacturer or qualified of order personnel to avoid the risk a WARNING DURING OPERATION gt Do not attempt to repair move modify or reinstall the unit on your own Make sure that these installations are carried out by qualified personnel to avoid electric shock or fire gt Do not place any obstacles in front of the unit Make sure that the unit is correctly ventilated at all times Do not place clothing or oth
7. set between On and Off Timer EU ae good on Set Cancel Sleep Oe mnizons to turn on off the air conditioner and good sleep mode On Timer of mpizone mode cannot be set out separately To Cancel the On Timer Set Cancel 1 Press the 5 button to cancel the On Timer If you press the lt button both the On Timer and the Off Timer are canceled O 2 e wor On et Cancel Sleep A Setting the Off Timer You can set the Off Timer to turn off the air conditioner automatically at the appointed time within a range of 30 minutes to 24 hours 1 Press the button Down 2 Press the or v5 buttons until the desired time is displayed to set the Off Timer You can set the time between 0 5 hour and 24 hours 3 Press the 5 button to complete the setting Result The remaining time is displayed The timer indicator stops blinking The air conditioner turns off automatically at the appointed time and the Off Timer setting disappears If you would like to turn the air conditioner on after 2 hours and to operate it for 2 hours during non operation 1 Press the amp button Down 2 Press the or 5 buttons until 2 0 Hr is displayed Set Cancel 3 Press the CD button 4 Press the an button Down 5 Press the cy or y3 buttons until 4 0 Hr is displayed Set Cancel 6 Press the _ button If you would like to turn on the ai
8. AQO9V A Series AQ12V A Series AQ18V A Series AO24VX A Series Split type Air Conditioner Cooling and Heating E DB98 27045A 2
9. Contents PREPARATION m Safety Precautions m Name of Each Part m Remote Control Buttons and Display m Inserting the Remote Control Batteries m Getting Started OPERATION m Selecting Auto Mode m Selecting Cool Mode m Selecting Heat Mode m Selecting Dry Mode m Selecting Fan Mode m Selecting the Turbo Function m Selecting the Energy Saving Function m Selecting good sleep Mode m Adjusting the Airflow Direction m Selecting Auto Cleaning Function m Setting the On Timer m Setting the Off Timer m Operating Your Air Conditioner Without the Remote Control m Selecting mpizone Mode emen RECOMMENDATIONS FOR USE m Cleaning Air Filter on Your Air Conditioner 25 m Keeping Filters clean meme m Temperature and Humidity Ranges m Operating Recommendations m Solving Common Problems Register your product at www samsung com global register Safety Precautions The following safety precautions are provided to protect the users safety and prevent property damage Make sure to read the followings and use the air conditioner properly D Keep this user s manual together with the installation manual in a handy place so that you can find it whenever you need to see it after reading this manual thoroughly N WARNING This indicates the possibility of serious injury or death e This indicates the possibility of serious injury or damage to environments when A CAUTION operated
10. The indoor unit beeps The fan speed adjusts automatically Selecting Cool Mode You can select Cool mode if you want to cool your room You can adjust the temperature and the fan speed when cooling 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps 2 Press the o button on the remote control until Cool is displayed Result The indoor unit beeps each time you press the O button The air conditioner runs in Cool mode Set Temp You can change modes at any time Mode G Speea Set Temp Im Auto CE ic 3 Press the O button to adjust the temperature until the required temperature is displayed You can set the temperature between 16 C and 30 C Result Oo Each time you press the 8 button The temperature adjusts by 1 C The indoor unit beeps if the room temperature is higher than the selected temperature the air conditioner starts cooling If the room temperature reaches the set temperature the air conditioner stops cooling but the fan continues to operate 4 Press the c5 button to select the fan speed until the reguired setting is displayed Set Temp Il Auto gt Low gt Medium gt High gt Turbo Auto L E C Result Each time you press the eS button the indoor unit beeps GO es EIN 5 To control the airf
11. conditioner s features please read this manual carefully before using You have already seen the basic description of the unit on pages from 8 to 10 Starting with the next page you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use three different symbols A PRESS PUSH HOLD DOWN Selecting Auto Mode Zati Mode Fan Speed CD You can select Auto mode if you want to cool or heat your room automatically You can adjust the temperature in this mode 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last 4 The indoor unit beeps Auto Set Temp Auto Ju c G Speea Set Temp Auto pay 1 c 2 Pressthe button on the remote control until Auto is displayed Result The indoor unit beeps each time you press the O button The air conditioner runs in Auto mode 4 Auto mode cools or heats the room depending on the set temperature 4 The air conditioner changes from Cool or Heat mode automatically depending on the current temperature You can change modes at any time 3 Press the 1O button to adjust the temperature until the required temperature is displayed You can set the temperature between 16 C and 30 C Result Oo Each time you press the OIO button The temperature adjusts by 1 C
12. e sa object on it 3 baby or an old person di CAUTION DURING OPERATION Do not touch the pipes connected to the air conditioner OTHERS gt Do not use the air conditioner to maintain the machine food pet plant or cosmetics gt Do not give excessive shock to the air conditioner a se a gt gt Be sure that the air filter not to be exposed to direct sunlight for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance gt Turn off the air conditioner and if the fan stops to operate clean the air conditioner gt Do not clean the air directly or with benzene thinner or alcohol gt Dispose of the packaging material in accordance with the local requirements gt Be sure to insert the air filter gt The appliance is not intended conditioner by spraying water gt The maximum input power amp current is measured according to the IEC standard and the input power amp current is measured according to the ISO standard gt The surface of the heat exchanger is sharp so be careful of it when cleaning gt All of the manufacturing and packaging materials used for your new appliance are compatible with the environment and can be recycled Name of Each Part The design and shape can be changed according to the model y
13. ed automatically Silence Purifies the indoor air with silence Rapid Purifies the indoor air quickly Nowe Ifmpizone mode is turned on when the air conditioner runs You cannot select the mpizone operation types by pressing mpizone H the Cea button The mpizone mode runs only in Auto The mpizone mode will also stop by pressing the Power button of the panel 4 mpi Micro Plasma lon For the best use of your air conditioner you must clean it every 2 weeks regularly to remove the dust that accumulates on the air filter CAUTION Before cleaning your air conditioner ensure that you have switched off the breaker used for the unit 1 Open the front panel by pulling tabs on the lower right and left sides of the indoor unit 2 Detach the front panel by pulling it forwards 3 Hold the edge of the air filter under the front panel and pull to release 4 Remove all dust on the air filter with a vacuum cleaner or brush 5 When you finish insert the top of the filter into the slot and fix it to Body Air filter 5 tabs or 3 tabs of the grille 6 Clean the front panel with a damp cloth and mild detergent do NOT use benzene solvents or other chemicals 7 Reassemble the air filter and the front panel If you ha
14. er materials over it gt Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury Keep children away from the unit gt Never spill any kind of liquid into the unit Should this happen unplug or main switch off the unit and contact an authorized service center gt When using a wireless remote control the distance should not be more than 7 meters from the air conditioner If applicable gt If the wireless remote control is not used for a long time remove the batteries If applicable gt The manufacturer declines any liability for damage resulting from modifications or errors in the electrical or hydraulic connections gt Do not connect the electric heater to the air conditioner or repair it with your discretion gt Failure to observe the installation instruction or use of the unit under conditions other than those indicated in the table Operating limit of the unit installation manual will immediately invalidate the unit warranty gt Do not place any materials so that children cannot step on it T WARNING DISPOSING THE UNIT gt Before throwing out the device it is necessary to pull back the battery cells and get rid of them safely for recycling reasons 1 CAUTION WHEN NSTALLING gt Install the air conditioner avoiding direct sunlight or heater especially water gt When you need to
15. ing function before adjusting the temperature f cH ESaver 4 Press the C5 to select the fan speed until the required setting is displayed Auto gt Low gt Medium gt High Result Each time you press the om button the indoor unit beeps Set Temp THT esaver Auto E ul Cc 5 To control the airflow direction refer to page 20 Selecting good sleep Mode good sleep mode helps users to fall asleep well after going to bed whether being too hot to sleep or being awakened by coldness The good sleep mode can be selected only when the air conditioner is switched on or off in cool heat mode Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps Car O Fan Cc 2 Press the O button to select cool or heat mode Result The indoor unit beeps each time you press the button The air conditioner runs in cool or heat mode 1 Press the On Off button Set Temp 3 Pressthe i button Result The timer indicator is displayed e 4 The Offtimer is blinking on the remote control Mode Speea 4 To set the good sleep Off timer press the Bars buttons once or more times a until the required Off time is displayed Result The good sleep mode will be automatically stopped in 8 hours if the operation time is not set You can set the Off timer by pressing the D buttons t
16. irflow blade moves up and down to increase the efficiency of the cooling or heating operation E 1 Press the button until the required direction is set Set Temp mam Result The outer blade is adjusted vertically GE 2 Press the CQ button again to move the blade up and down automatically during operation Digital On Off EP e 3 Press the D button again to stop the blade moving up and down Nota If you turn the air conditioner Then the blade off is closed completely On set to the default position Adjusting the Airflow Direction Horizontally You can adjust airflow direction horizontally manually The inner blades with small fins move the air in the desired direction 1 Adjust the inner blades by moving them left or right Make sure do not touch the inner blades during operation It may cause injury on your fingers Selecting the Auto Cleaning Function Auto cleaning function offers inside air conditioner dry to prevent mold growth This feature allows you to use the air conditioner more clean and fresh air Remote Control 1 Press the button gt When the air conditioner is turned off The J indicator on the indoor unit display appears and the Auto cleaning function runs Set Temp Auto gt When the air conditioner is turned on The E l indicator on the indoor unit display appears and the Auto cleaning function runs after s
17. low direction refer to page 20 Selecting Heat Mode You can select Heat mode if you want to heat your room You can adjust the temperature and the fan speed when heating 1 Press the On Off button Result The operation indicator on the indoor unit lights up The air conditioner starts up in the mode you selected last The indoor unit beeps 65 O Fan Cc 2 Press the o button on the remote control until Heat is displayed Result The indoor unit beeps each time you press the o button Set Temp 4 The air conditioner runs in Heat mode an Heat JIL Note You can change modes at any time Auto G Te 3 Press the O button to adjust the temperature until the required temperature is displayed Mode A af Speea You can set the temperature between 16 C and 30 C a Result Each time you press the button 30 The temperature adjusts by 1 C auto lie The indoor unit beeps If the room temperature reaches the set temperature selected temperature 5 C the air conditioner stops heating but the fan is still operating 4 The air conditioner starts heating provided that the room temperature is lower than the desired temperature selected temperature 3 C 4 Press the Cs button to select the fan speed until the required setting is displayed Set Temp JC Auto gt Low gt Medium gt High Auto E c Result Each time you press the gt button the indoor unit beeps
18. ntrol and insensible air stream Wake Up Stage This stage supports comfortable intermittent air to the room to raise human body temperature for refreshing wake up When the set time is over 8 hours this section will be repeated 1 2 3 4 5 er g Timethr gt The recommended temperature is set between 25 C and 27 C and 26 C is the most ideal temperature for comfortable sleep gt Airflow blades and fan speed are controlled automatically as the above 3 stages in good sleep mode gt Set Off timer in good sleep mode over 5 hours You feel disturbed sleep if the good sleep is set too short or long because the basic off timer is set for 8 hours gt If the good sleep mode is set less than 4 hours the operation will be stopped after the set time If the good sleep mode is set over 5 hours it will run as Wake Up stage for the last one hour before stop In heat mode gt The temperature decreases by 1 C every hour After a decrease of 2 C the temperature is maintained Start Stop time time gt You can set the airflow blades and fan speed separately during good sleep Set thr_2hr mode Adjusting the Airflow Direction Adjust the airflow direction to circulate the air according to various needs By adjusting the airflow direction the efficiency of the air conditioner can be increased Adjusting the Airflow Direction Vertically You can adjust the airflow direction vertically The outer a
19. o turn off the good sleep mode automatically at the Sise Bal CS appointed time within a range of 30 minutes to 12 hours imer Up Down On Up Se Each time the 25 05 buttons are pressed the time is EO 2 increased by 30 minutes or 1 hour good sleep mode will be stopped at the appointed off time Set Cancel Set Temp 5 Press the c button 4 Result The remaining time is displayed Auto c good mp Nowe In the case of selecting good sleep mode or adjusting the extra sleep off Llar time for good sleep mode you should press the 5 button Set Cancel within 10 seconds If you do not press the 5 button within 10 seconds good sleep mode will be canceled automatically So el 6 Press the button to adjust the temperature until the desired temperature is displayed You can set the temperature between 16 C and 30 C Result Each time you press the button The temperature adjusts by 1 C The indoor unit beeps a In cool mode good sleep mode keeps the skin temperature at the best during the 3 stages such as Falling Asleep Stage gt Sound Sleep Stage gt Wake Up Stage in order Falling Asleep Stage This stage supports the environment to quickly cool down Together with comfortable intermittent air you will be able to fall asleep quickly Sound Sleep Stage This stage helps users to take deep sleep and keep the healthy skin by controlling wavy temperature co
20. p in the mode you selected last The indoor unit beeps O Fan QIO Select Fan mode if you want to ventilate your room It helps to refresh 2 Pressthe o button on the remote control until Fan is displayed Result The indoor unit beeps each time you press the O button The air conditioner runs in Fan mode The temperature is set automatically Note You can change modes at any time Fan Speed 3 Press the C3 button to adjust the temperature until the reguired setting is displayed Low Medium gt High Result Each time you press the c5 button the indoor unit beeps G Fan Speed 4 Tocontroltheairflow direction refer to page 20 Selecting the Turbo Function You can select the Turbo Function if you want to cool or heat your room as guickiy as possible The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected 1 Press the On Off button Result The operation indicator on the indoor unit lights up 4 The air conditioner starts up in the mode you selected last I 4 4 The indoor unit beeps Cm 2 Pressthe button O Fan C3 Result The temperature and fan settings are adjusted automatically 4 The air conditioner cools or heats the room as quickly as possible E T After 30 minutes the air conditioner is reset automatically to
21. p to 70 80 depending on the operating condition If you use the air conditioner in temperatures over 32 C indoor temperature the cooling capacity may drop Operating Recommendations When you use your air conditioner it is recommended that you read the following Topic Recommendation Heating capacity The heat pump inside the air conditioner absorbs heat from outside air and brings itindoors If the temperature of the outside air drops the air conditioner heats less If the room is not warm enough use an additional heating appliance Warm air circulation The air conditioner circulates warm air to heat your room It will take some time to warm the air in your room entirely after the air conditioner turns on Therefore turn the air conditioner on in advance Frost When you select the Heat mode frost may form in the outdoor unit due to low temperature and high humidity If this happens The heating operation is stopped The air conditioner defrosts automatically for about 7 minutes After about 7 minutes the air conditioner starts operating again normally High indoor and If both the indoor and outdoor temperatures are high when you select the Heat mode outdoor temperatures the fan and the compressor of the outdoor unit may stop periodically This is normal wait until the air conditioner turns on again Power failure If a power failure occurs when the air conditioner is operating the air conditioner will turn off
22. r conditioner and then to turn off it automatically at the appointed time by using On Off Timer during operation you should set the On Timer longer than the Off Timer Make sure that the air conditioner will not continue to run after On Timer setting is confirmed You can check or change the mode and or the temperature by pressing the button or the QIO button after setting the Off Timer The most recently used function is set between On and Off Timer to turn on off the air conditioner and good sleep mode Off Timer of mpizone mode cannot be set out separately Ifyou would like to turn off the air conditioner and then to turn on it again automatically at the appointed time by using On Off Timer during non operation you should set the Off Timer longer than the On Timer To Cancel the Off Timer 1 Set Cancel Press the __ button to cancel the Off Timer If you press the button both the On Timer and the Off Timer are canceled Set Temp Auto IL Auto L c BUS Mpizone On Off Clean Mode Set Temp Auto 7 mpizone Off Down On Off Clean Mode O mi0 IU Auto L E On Co Set Temp Auto good Set Cancel Sleep Set Temp Auto ei a good on Set Cancel Sleep CC CD CO Operating Your Air Conditioner Without the Remote Control You can operate your air conditioner directly wi
23. t 3 minutes to cool or heat the room Check if the drain pipe is too long The fan speed is not adjusted In Auto or Dry mode the fan speed is selected automatically The remote control does Check if the battery is discharged Replace the battery not operate Check if the remote control sensor is blocked Check if the air conditioner is placed near strong light The Timer is not set Check if you pressed the 5 button after selecting time Odor is permeated in the Check if you use the air conditioner in smoky area or there is a smell room during operation Ventilate the room or select the Fan mode for 1 2 hours The indoor unit indicator Press the button to turn on the air conditioner again flashes Switch the circuit breaker off and switch on it again Strange sound is heard from The sound is heard when the refrigerant gas flow is changed depending the air conditioner on the use of the air conditioner When you press the button noise may be heard that the air conditioner sense the airflow blade Water drops from the outdoor Water may form due to the difference of the temperature unit connection part ELECTRONICS Contact SAMSUNG WORLD WIDE If you have any comments or questions regarding a Samsung product contact the SAMSUNG customer care center Customer Care Center Website SOUTH AFRICA 0860 7267864 SAMSUNG www samsung com za U A E 800SAMSUNG 7267864 www samsung com mea ex USER S MANUAL
24. th a new one into the slot Use the deodorizing filter you purchased after removing the vinyl wrap Anti allergy Filter 4 Close the front panel Deodorizing Filter Front panel You should clean the filters every year even if the replacing period might be different depending on how long and where you are using You can purchase deodorizing filter at the customer care center 4 The filter function is not affected even if deodorizing filter and anti allergy filter are inverted Temperature and Humidity Ranges If you check the following tables you can use your air conditioner more efficiently If the air conditioner is used at Then Heating capacity The air conditioner may stop operating for the reason of protection Low temperatures Water may leak and some malfunction may occur if the heat exchanger freezes Water may condense and drip from the surface of the indoor unit if you don t use Protection mechanism the air conditioner for an extended period of time Operation Outdoor Temperature Indoor Temperature Indoor Humidity Heating 0 C to 24 C approx 27 C or less Cooling 21 C to 43 C approx 16 C to 32 C approx 80 or less Dehumidifying 18 C to 43 C approx 16 C to 32 C approx X Ifthe outdoor temperature is as low as 0 C the heating capacity drops u
25. thout the remote control 1 Toturn the air conditioner on press the ON OFF switch on the right side of the indoor unit Result The Operation indicator on the indoor unit lights up 4 The indoor unit beeps The air conditioner starts up in the appropriate mode for the room temperature The air conditioner changes the Cool or Heat mode automatically depending on the current temperature during operation Room Temperature Operating Mode Lower than 24 C Heating Higher than 24 C Cooling 2 Toturn the air conditioner off press the On Off button again ote ven if you turned the air conditioner on wi e On utton Even if you turned the ai diti ith the On Off butt you can control it with the remote control Selecting mpizone Mode On up A Auto Silence mpizone On Off Clean Mod The mpizone mode creates strong purified zone by decomposing harmful particles in the behavior of active hydrogen H and oxygen ion O Thempizone mode can be selected whether the air conditioner is turned on or not 1 Press the og button 4 The air conditioner starts up in mpizone Auto mode automatically The mpizone mode also runs when the air conditioner is turned on 4 By pressing the a button again the mpizone mode is canceled 2 Press the Saige to select the mpizone operation types Whenever press the REEE button Auto Silence and Rapid will appear repeatedly 4 Auto Controls the fan spe
26. ton Auto Cool Dry Fan Heat Swing button Digital ONOfN Digital On Off buttn D CD Turbo button gt e Auto Cleaning button a g D 22 CFG Energy saving button Pee EE On i Up Set Cancel sleep good sleep button 4 CA CF lt lt Timer Set Cancel button g H mpi m Off Down On Off Clean Mode Fan speed adjustment button On Timer button Off Timer button ll Xi Cd CT mpizone mode adjustment button Time adjustment button mpizone On Off button Digital 7 On Off button If you want to turn on or off the Display of the indoor unit SAMSUNG during operation press the stain button on the remote control Inserting the Remote Control Batteries You must insert or replace the remote control batteries when You purchase the air conditioner 4 The remote control does not work correctly Use two AAA LRO3 1 5V batteries Do not use old and new batteries or different kinds of batteries together Insert two batteries correctly as indicated by the and symbols 1 Remove the battery cover in the rear of the remote control by pushing it with your thumb 2 Insert two batteries respecting the polarities as indicated by the and symbols 3 Close the cover by sliding it back in place Getting Started The User s Manual provides you with valuable information about your air conditioner In order to take full advantage of the air
27. topping the air conditioner operation gt Mode Operating time Auto cool Cool Dry 30 minutes Control Panel Auto heat Heat Fan 15 minutes Auto cleaning operating time varies according to the mode you selected before the air conditioner turned off The Auto Cleaning indicator appears only on the indoor unit display When the air conditioner is turned on the Auto cleaning function runs after stopping the air conditioner operation Setting the On Timer You can set the On Timer to turn on the air conditioner automatically at the appointed time within a range of 30 minutes to 24 hours 1 Press the C2 button Set Temp Auto Down 2 Press the cay or Cv buttons until the desired time is displayed to set mpizone the On Timer You can set the time between 0 5 hour and 24 hours On Off Clean Mode 3 Set Cancel Press the _ button to complete the setting Set Temp Auto Result The remaining time is displayed 4 The timer indicator stops blinking The selected mode and the temperature on the display disappear after 10 seconds 4 The air conditioner turns on automatically at the appointed time and the On Timer setting disappears 4 Press the button until the desired mode is displayed at the top of the remote control to select the mode in advance pk i Result The air conditioner operates in the selected mode when it is 4 turned on The most recently used function is
28. ve not used the air conditioner for a while select the Fan mode for 3 to 4 hours to dry the inside of the air conditioner Keeping Filters clean Cleaning Anti allergy Filter Anti allergy filter protects you from allergy causing particles even if you raise petsathome 1 Open the upper front panel by pulling the lower right and left tabs of the panel 2 Detach the anti allergy filter sky blue by pulling it forwards Deodorizing Filter 3 Wash the filter with clean water Make sure not to rub the filter when washing Anti allergy Filter n D 4 Dryitin the shade and then insert it in its place Avoid direct sunlight when dry the anti allergy filter If not it may cause Front panel variation 5 Close the front panel You should clean the filters every 3 months even if the cleaning period might be different depending on how long and where you are using 4 The filter function is not affected even if deodorizing filter and anti allergy filter are inverted O Ef Replacing Deodorizing Filter Activated carbon is incorporated in the Deodorizing filter efficiently absorbing cigarette smoke pet odors and other unpleasant smells 1 Open the upper front panel by pulling the lower right and left tabs of the panel 2 Detach the deodorizing filter black by pulling it forwards 3 Replace the deodorizing filter wi