Home

DG75 : Reference and Installation manual

image

Contents

1. R glages des cavaliers LED Indicator s Indicadores LED Voyant s DEL s OFF Disabled Deshabilitado D sactiv ON Enabled Habilitado Activ A Digital Shield Sensitivity Blindaje Shield Digital Sensibilidad Algorithme num rique Shield Sensibilit LED SHLD OFF High Shield Blindaje Superior Protection lev e ON Normal Shield Blindaje Normal Protection normale A Processing Type Tipo de Procesamiento Type de traitement OFF Dual Edge Polaridad Doble Divis ON Single Edge Polaridad Simple Simple A DUAL A default de f brica par d faut Figure Figura 5 PCB Height Altura de la PCI Hauteur du PCB Align PCB with this mark od Alinear la PCI con esta marca Aligner le PCB avec cette marque LED Feedback LED de Confirmaci n R troaction DEL Legend Legend L gende R Red Rojo Rouge G Green Verde Verte ZN Off D sact On Act AV Flashing Parpadeo Clignote LED State Condition On 3 seconds Alarm signal generated Encendido 3 segundos Se gener se al de alarma Allum e 3 secondes Signal d alarme g n r Ha Movement signal does not reach required energy for an alarm Parpadeo Se al de movimiento no alcanza la energ a necesaria para generar una alarma Clignote Signal de mouvement n atteint pas l nergie requise pour une alarme Flash 5 seconds Power up self test Parpadeo 5 segundos Prueba autom tica en encendid
2. ajustarse correctamente la altura de la PCI Para hacerlo aflojar el tornillo de la PCI ver la Figura 4 deslizar la PCI hacia arriba o abajo y alinearla con la leng eta de altura de la PCI ver la Figura 5 Cuando se alcance la posici n deseada ajustar delicadamente el tornillo de la PCI La altura ptima de instalaci n del DG75 es de 2 1m sin embargo la PCI puede ser ajustada para permitir instalaciones entre 1 1m y 3 1m ADEVERTENCIA El ajuste incorrecto de la altura afecta la eficacia del detector Prueba Caminando A 20 C 68 F en los modos de Blindaje Normal y de Procesamiento de Polaridad Simple no se deber a poder atravesar m s de una zona completa que consiste de 2 haces elementos de detecci n izquierdo y derecho del sensor en el rea de cobertura con cualquier tipo de movimiento caminando despacio r pido o corriendo En el modo de Blindaje Superior se requiere el doble de la cantidad de movimiento para generar una alarma El ancho aproximado de un haz completo a 11m 35ft del detector es de 1 8m 6ft Para efectuar la prueba caminado moverse siempre atravesando la trayectoria de detecci n no hacia el detector Estructura de Haces El alcance de detecci n del DG75 es de 11m x 11m 35ft x 35ft con un ngulo de visi n de 90 Para ayuda sobre la selecci n de un lugar de instalaci n y la realizaci n de pruebas caminando ver la Figura 2 Francais Description Le Digigard DG75 est un d tecteur de mo
3. s 0 6ft s a 11 5ft s 20 C a 50 C 4 F a 122 F Salida de alarma Velocidad de detecci n Temperatura de funcionamiento Est ndares Ambientales Cumple con EN 50131 Security Grade 2 Environmental Class El rel de Forma C no ha sido examinado respecto a su conformidad con EN 50131 Patentes Una o m s de las siguientes patentes EE UU podr a aplicarse 7046142 6215399 6111256 6104319 5920259 5886632 5721542 5287111 5119069 5077549 y RE39406 y otras patentes pendientes podr an aplicarse Patentes canadienses e internacionales tambi n podr an aplicarse Lente LODIFFO patente 44 787 722 EE UU Patentes canadienses e internacionales tambi n podr an aplicarse LODIFF es una marca registrada de Fresnel Technologies Inc Marcas de comercio Digigard y Shield son marcas de comercio o marcas registradas de Paradox Security Systems Ltd o de sus afiliados en Canad Estados Unidos y o otros pa ses Certificaci n Para informaci n actualizada respecto a la homologaci n de productos como UL y CE s rvase visitar nuestro sitio Web en www paradox com Garant a Para una informaci n detallada acerca de la garant a de este producto consultar la Declaraci n de Garant a Limitada en ingl s que se encuentra en el sitio web de paradox www paradox ca terms El uso de este producto Paradox significa la aceptaci n de todos los t rminos y condiciones de la garant a 2010 Paradox Security Syst
4. DG75 TI03 OIGIGARD DG75C High Security Motion Detector with Pet Immunity Instructions Instrucciones PA RADO X ECURITHY SYSTEMS PARADOX COM Printed in Canada 03 2010 English Description The Digigard DG75 is an indoor digital dual optic high performance PIR motion detector Featuring True Pet Immunity the DG75 allows one pet up to 40kg 901b to move freely through the protected area without generating an alarm Installation The DG75 can be installed as either a flat mount or corner mount detector At the recommended installation height of 2 1m 7ft to 2 7m 9ft 10 the DG75 provides full coverage for distances of 1 5m 5ft to 11m 35ft see Figure 2 on reverse Ensure that the PCB height setting matches the actual installation height see Figure 4 and Figure 5 on reverse WARNING e Install the unit according to the following instructions Failure to do so may result in compromised detector performance e Do not install the detector near the following sources of interference reflective surfaces direct sunlight moving cars direct air flow from vents fans windows sources of steam oil vapor infrared light and objects causing temperature changes such as heaters refrigerators and ovens e Ensure that the installation site is free of any obstacles that may partially or completely obscure the detector s field of view e False alarms can be caused by a pet climbing onto furniture To prevent false
5. FFO brevet 44 787 722 U S LODIFFO est une marque d pos e de Fresnel Technologies Inc Marques de commerce Digigard et Shield sont des marques de commerce ou des marques de commerce d pos es de Syst mes de s curit Paradox Lt e ou de ses soci t s affili es au Canada aux tats Unis et ou dans d autres pays Certification Pour les renseignements les plus r cents concernant l approbation UL et CE des produits veuillez visiter le www paradox com Garantie Pour tous les renseignements sur la garantie de ce produit veuillez vous r f rer la D claration de garantie limit e qui se trouve sur le site Web au www paradox com terms L utilisation des produits Paradox signifie l acceptation de toutes les modalit et conditions de la garantie Syst mes de s curit Paradox Lt e 2010 Tous droits r serv s Sp cifications sujettes changement sans pr avis
6. LODIFFO a registered trademark of Fresnel Technologies Inc Trademarks Digigard and Shield are trademarks or registered trademarks of Paradox Security Systems Ltd or its affiliates in Canada the United States and or other countries Certification For the latest information on products approvals such as UL and CE please visit www paradox com Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www paradox com terms Your use of the Paradox product signifies your acceptance of all warranty terms and conditions 2010 Paradox Security Systems Ltd All rights reserved Specifications may change without prior notice Especificaciones Inmune a mascotas Tipo de Sensor Cobertura 90 est ndar Altura de Instalaci n Rechazo a interferencias electromagn ticas y de radiofrecuencia Geometr a del Sensor Tensi n de entrada Consumo de corriente Interruptor antisabotaje Detection speed Operating temperature Environmental Standards De hasta 40kg 90lbs Infrarrojo de Dos Elemento x 2 11m 35ft X 11m 35ft 2 1m a 2 7m 7ft a 9ft 10V m de rechazo entre 10MHz a 1GHz Rectangular T pico de 11 a 16Vcc 15mA m x 6mA m n LED deshabilitado 150mA 28Vcc N C Lente Lente Fresnel de 2da generaci n LODIFF segmentos DG75 Rel de Forma A de 100mA 28Vcc N C DG75C Rel de Forma C de 200mA 28Vcc N C N A Ingreso 0 2m s a 3 5m
7. aje en superficie plana o en esquina Instalado a la altura recomendada de 2 1m 7ft a 2 7m 9ft 10 el DG75 ofrece una cobertura total a una distancia de 1 5m 5ft hasta 11m 35ft ver la Figure 2 al verso Verificar que la altura de la placa de circuito impreso coincide con la altura de la instalaci n ver la Figure 4 y la Figura 5 al verso ADVERTENCIA e Instalar la unidad siguiendo las siguientes instrucciones De lo contrario el rendimiento de los detectores podr a verse afectado e No instalar el detector cerca de las siguientes fuentes de interferencia superficies reflectantes luz solar directa autom viles en movimiento corrientes de aire directas de sistemas de ventilaci n ventiladores y ventanas fuentes de vapor humo de aceite fuentes de luces infrarrojas y objetos que provoquen cambios de temperatura como aparatos de calefacci n refrigeradores y hornos e Comprobar que el lugar de la instalaci n est libre de obst culos que podr an oscurecer el campo de visi n del detector e Un animal de compa a que trepa sobre los muebles podr a causar falsas alarmas Para evitar falsas alarmas no poner muebles de 0 9m 3ft o m s de altura a una distancia de 2 1m 7f o menos del detector Adem s evitar orientar el detector hacia una escalera por donde tenga acceso la mascota e No toque la superficie del sensor pues puede provocar un mal funcionamiento del detector De ser necesario limpiar la superficie del s
8. alarms ensure that furniture 0 9m 3ft or higher is not placed within 2 1m 7ft of the detector In addition do not aim the detector at a stairway to which a pet may have access e Do not touch the sensor surface as this could result in a detector malfunction If necessary clean the sensor surface using a soft cloth with pure alcohol For CUL Listed applications the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code The DG75 s Pet Immunity feature has not yet been investigated by UL Installing the DG75 1 Select the detector s location 2 To remove the cover remove the cover screw and use a screwdriver to release the cover release pin see Figure 1 on reverse 3 Loosen the PCB screw and gently remove the PCB 4 Drill or punch out the selected knockout holes from the DG75 back cover see Figure 1 on reverse and secure to surface using appropriate mounting screws 5 Ensure that the PCB height setting matches the actual installation height see Figure 4 and Figure 5 on reverse Failure to do so will compromise detector effectiveness A walk test should be performed following installation and any PCB adjustment to verify detector coverage see Walk testing Detector Settings Detector settings can be modified using the three jumpers located on the DG75 PCB see Figure 4 on reverse Single or Dual Edge Processing DUAL This setting determines the DSP Digital Signal Processing op
9. ant sur des meubles Pour pr venir les fausses alarmes s assurer que les meubles 0 9 m 3 pi ou plus soient plac s plus de 2 1 m 7 pi du d tecteur viter aussi d orienter le d tecteur vers un escalier accessible un animal domestique e Ne pas toucher la surface du capteur car cela pourra t entra ner un mauvais fonctionnement du d tecteur Au besoin nettoyer la surface du capteur l aide d un chiffon doux et d alcool pur Pour les applications list es CUL l unit doit tre install e conform ment la Partie 1 du Code canadien de l lectricit La caract ristique d insensibilit aux animaux du DG75 n a pas encore t examin e par l UL Installation du DG75 1 Choisir emplacement du d tecteur 2 Utiliser un tournevis pour desserrer la languette de d gagement et retirer le couvercle voir Figure 1 au verso 3 Desserrer la vis de la carte de circuits imprim s et retirer cette derni re avec soin 4 Percer les trous sur le couvercle arri re du DG75 voir Figure 1 au verso et le fixer la surface l aide des vis appropri es 5 S assurer que le r glage de la hauteur de la carte de circuits imprim s corresponde la hauteur r elle de l installation voir Figure 4 et Figure 5 au verso sans quoi l efficacit du d tecteur pourrait tre compromise Un essai de marche devrait tre effectu la suite de toute installation et d ajustement de carte de circuits imprim s afin de v rifi
10. au verso Mise sous tension du d tecteur Alimenter le d tecteur en branchant les bornes AUX et AUX du panneau de contr le aux bornes et du d tecteur voir Figure 3 au verso La mise sous tension du d tecteur lance un autotest et le voyant rouge clignote pendant 5 secondes Lorsque le voyant rouge cesse de clignoter le d tecteur est pr t Adjustement de la hauteur de la carte de circuits imprim s Afin d assurer la couverture ad quate du d tecteur et de r duire les fausses alarmes il est n cessaire d ajuster correctement la hauteur de la carte de circuits imprim s Pour ajuster la hauteur desserrer la vis retenant la carte de circuits imprim s voir Figure 4 au verso faire glisser cette derni re vers le haut ou vers le bas et l aligner avec l onglet de hauteur voir Figure 5 au verso Une fois la position d sir e obtenue resserrer la vis de la carte de circuits imprim s avec soin La hauteur optimale pour une installation de DG55 DG65 est de 2 1 m Cependant la carte de circuits imprim s peut tre ajust e de fa on accommoder des installations entre 1 1 m et 3 1 m AVERTISSEMENT Un mauvais ajustement de la hauteur pourrait compromettre l efficacit du d tecteur Essai de marche A 20 C 68 F en mode de protection normale et en mode de traitement simple un humain ne devrait pas pouvoir traverser plus d une zone compl te compos de 2 faisceaux d tecteurs gauche et dr
11. d align with the PCB height tab see Figure 5 on reverse When you reach the desired position gently tighten the PCB screw The optimum height for DG75 installation is 2 1m however the PCB can be adjusted to accommodate installations between 1 1m and 3 1m WARNING Improper height adjustment will compromise detector effectiveness Walk testing At 20 C 68 F in Normal Shield mode and Single Edge Processing mode you should not be able to cross more than one complete zone consisting of 2 beams left and right sensor detecting elements in the coverage area with any kind of movement slow fast walking or running In High Shield mode the amount of movement required to generate an alarm is doubled The approximate width of a full beamat 11m 35ft from the detectoris 1 8m 6ft To walk test always move across the detection path not toward the detector Beam Pattern The DG75 features a detection range of 11m x 11m 35ft x 35ft with a 90 viewing angle To aid in selecting an installation site and performing walk tests refer to Figure 2 on reverse Espa ol Descripci n El Digigard DG75 es un detector de movimiento infrarrojo digital para exteriores de funcionamiento superior con optica doble Con Inmunidad Real Contra Mascotas el DG75 permite a un animal de compa a de hasta 40kg 901b pasear libremente por el rea protegida sin que por ello genere una alarma Instalaci n El detector DG75 puede ser instalado en un mont
12. de Polaridad Simple debe ser usado en ambientes normales con m nimas fuentes de interferencia El Procesamiento de Polaridad Doble ofrece un mayor rechazo a las falsas alarmas si el detector est ubicado cerca de fuentes de interferencia que pueden afectarlo negativamente Configuraci n del Blindaje Digital Shield SHLD En el modo Blindaje Normal el detector est configurado para ambientes normales En el modo de Blindaje Superior el detector est configurado para ambientes de alto riesgo interferencias potenciales y por consiguiente brinda una inmunidad acrecentada contra las falsas alarmas NOTA En el modo de blindaje superior el tiempo de detecci n de grandes movimientos no ser afectado Sin embargo el tiempo de detecci n de peque os movimientos o de movimientos que ocurran lejos del detector ser doblado Configuraci n de LED LED Usar esta configuraci n para habilitar o deshabilitar las luces LED verde y roja Ver Luces LED de Confirmaci n al verso Encendido del Detector Suministrar alimentaci n conectando los terminales AUX y AUX de la central a los terminales y del detector ver la Figure 3 al verso Encender el detector inicia una auto prueba y la luz LED roja parpadea por 5 segundos Cuando la luz LED roja deja de parpadear el detector est listo Ajuste de la Altura de la PCI Para asegurar la cobertura correcta del detector y disminuir las falsas alarmas debe
13. ems Ltd Todos los derechos reservados Las especificaciones pueden cambiar sin previo aviso Sp cifications Insensibilit aux animaux Type de capteur Couverture 90 standard Hauteur d installation Protection contre les perturbations lectromagn tiques et les interf rences radiofr quences G om trie du capteur Tension d entr e Consommation de courant Interrupteur de s curit Jusqu 40 kg 90 Ib l ment double infrarouge x 2 11 m 35 pi X 11 m 35 pi 2 im 2 7m 7pi 9 pi R jection de 10 V m entre 10 MHz et 1GHz Rectangulaire G n ralement 11 16 Vc c 15 mA max 6 mA min DEL d sact 150 mA 28 Vc c N F Lentilles Lentilles Fresnel 2 me g n ration segments LODIFF Sortie d alarme DG75 Relais de forme de 100 mA 28 Vc c N F DG75C Relais de forme C de 200 mA 28 Vc c N F N O Ingress 0 2 m s 3 5 m s 0 6 pi s 11 5 pi s 20 C 50 C 4 F 122 F Vitesse de d tection Temp rature de fonctionnement Standards environnementaux Conforme EN 50131 Security Grade 2 Environmental Class COMA de forme C n a pas encore t examin pour la conformit avec EN Brevets Un ou plusieurs des brevets suivants peuvent s appliquer 7046142 6215399 6111256 6104319 5920259 5886632 5721542 5287111 5119069 5077549 et RE39406 et d autres brevets en instance Des brevets canadiens et internationaux peuvent aussi s appliquer Lentilles LODI
14. ensor con un pa o delicado y alcohol puro Para aplicaciones homologadas por CUL la unidad debe ser instalada en concordancia con la Parte 1 del C digo El ctrico Canadiense La caracter stica de Inmunidad Contra Mascotas del DG75 a n no ha sido evaluada por UL Instalaci n del DG75 1 Seleccionar la ubicaci n del detector 2 Para quitar la cubierta retirar el tornillo de la cubierta y liberar la leng eta de sujeci n de la cubierta ver Figure 1 al verso mediante un destornillador 3 Aflojar el tomillo de laplaca de circuito impreso PCI y retirar delicadamente la PCI 4 Perforar los agujeros de la cubierta trasera del DG75 ver la Figura 1 al verso y fijarla a la superficie usando los tornillos de montaje adecuados 5 Verificar que la altura de la placa de circuito impreso coincide con la altura de la instalaci n ver la Figura 4 y la Figura 5 al verso De lo contrario la eficacia del detector se ver a comprometida Para verificar la cobertura del detector se debe efectuar una prueba caminando despu s de la instalaci n y tras todo ajuste efectuado a la PCI ver Walk testing Configuraci n del Detector Se puede modificar la configuraci n del detector mediante los tres puentes ubicados en la PCI del DG75 ver la Figura 4 al verso Procesamiento de Polaridad Simple o Doble DUAL Esta configuraci n determina el modo de funcionamiento de Procesamiento Digital de Se ales del detector El Procesamiento
15. er la couverture du d tecteur voir Essai de marche R glages du d tecteur Les r glages du d tecteur peuvent tre modifi s l aide des trois cavaliers situ s sur la carte de circuits imprim s du DG75 voir Figure 4 au verso Traitement simple ou divis DUAL Ce param tre d termine le mode op rationnel de traitement num rique du signal du d tecteur Le mode de traitement simple devrait tre utilis dans des conditions d environnement normal avec peu de sources d interf rence Le mode de traitement divis offre un meilleur rejet des fausses alarmes dans le cas o le d tecteur est plac pr s de sources d interf rence pouvant nuire au d tecteur de mouvement R glage de l algorithme num rique Shield TM SHLD En mode de protection normale le d tecteur est r gl pour des conditions d environnement normal En mode de protection lev e le d tecteur est r gl pour des conditions d environnement haut risque possibilit d interf rences et est donc pourvu d une immunit in gal e contre les fausses alarmes NOTE En mode blindage lev le temps de d tection pour les mouvements importants ne sera pas affect Cependant le temps de d tection pour les petits mouvements ou les mouvements se produisant loin du d tecteur sera doubl R glages des DEL DEL Utiliser ce r glage pour activer ou d sactiver la DEL rouge et la DEL verte DG65 seulement Voir R troaction de la DEL
16. erational mode of the detector Single Edge Processing mode should be used in normal environments with minimal sources of interference Dual Edge Processing Mode provides better false alarm rejection in the case where the detector is placed near sources of interference that can adversely affect the motion detector Digital Shield Setting SHLD In Normal Shield mode the detector is set for normal environments In High Shield mode the detector is set for high risk environments potential interferences and therefore provides greatly increased false alarm immunity NOTE In high shield mode detection time for large movements will not be affected however detection time for small movements or movements that occur far from the detector will be doubled LED Settings LED Use this setting to enable or disable the green and red LEDs Refer to LED Feedback on reverse Powering the Detector Apply power by connecting the terminals AUX and AUX of the control panel to the and terminals of the detector see Figure 3 on reverse Powering the detector initiates a self test and the red LED flashes for 5 seconds When the red LED is no longer flashing the detector is ready Adjusting the PCB Height To ensure correct detector coverage and reduce false alarms it is necessary to properly adjust the PCB height To adjust the PCB height loosen the PCB screw see Figure 4 on reverse slide the PCB up or down an
17. o Clignote 5 secondes Test automatique de mise sous tension Flash Signal does not match the characteristics of an alarm non movement signal Parpadeo La se al no re ne las caracter sticas de una alarma se al de sin movimiento Clignote Signal ne correspond pas aux caract ristiques d une alarme signal de non mouvement Specifications Pet immunity Sensor type Coverage 90 standard Installation Height RFI EMI rejection Sensor geometry Voltage input Current consumption Anti tamper switch Lens Alarm output Up to 40kg 9Olbs Dual Element Infrared x 2 11m 35ft X 11m 35ft 2 1m to 2 7m 7ft to 9ft 10V m rejection from 10MHz to 1GHz Rectangular Typically 11 to 16Vdc 15mA max 6mA min LED disabled 150mA 28Vdc N C 2nd generation Fresnel lens LODIFF9 segments DG75 Form A relay 100mA 28Vdc N C DG75C Form C relay 200mA 28Vdc N C N O 0 2m s to 3 5m s 0 6ft s to 11 5ft s Ingress 20 C to 50 C 4 F to 122 F Complies with EN 50131 Security Grade 2 Environmental Class Form C relay has not been investigated for compliance to EN 50131 Patents One or more of the following US patents may apply 7046142 6215399 6111256 6104319 5920259 5886632 5721542 5287111 5119069 5077549 and RE39406 and other pending patents may apply Canadian and international patents may also apply LODIFFO lens patent 44 787 722 U S Canadian and International patents may also apply
18. oit du capteur dans la zone de couverture et ce peu importe le mouvement effectu marche lente rapide ou course En mode de protection lev e la quantit de mouvement n cessaire la g n ration d une alarme est doubl e La largeur approximative d un faisceau maximal 11 m 35 pi du d tecteur est de 1 8 m 6 pi Lors de l essai de marche s assurer de toujours marcher d un c t l autre de la trajectoire de d tection et non en direction du d tecteur Diagramme de faisceau Le DG75 offre une port e de d tection de 11 m x 11 m 35 pi x 35 pi avec ange de prise de vue de 90 Pour aider la s lection du lieu d installation et l ex cution des essais de marche voir la Figure 2 au verso Figure Figura 1 Overview Vista General Vue d ensemble A DG75 lens Lente del 1 Exposed wire entry knockouts Agujeros para la DG75 Lentilles DG75 entrada de cables visibles Trous pour entr e de B LED indicator indicador c ble d couvert LED Voyant DEL 2 Hidden wire entry knockouts Agujeros para la C Cover screw and release entrada de cables ocultos Trous pour entr e de pin Tornillo y lengueta de c ble cach sujeci n de cubierta Vis et 3 Corner mount knockouts Agujeros para montaje languette de d gagement en esquina Trous pour montage en coin du couvercle 4 Flat surface mount knockouts Agujeros para montaje en superficie plana Trous pour montage sur surface plane A A Fig
19. ure Figura 2 DG75 Pet Array Beam Pattern Estructura de Haces Diagramme de faisceau 11m 36 1ft 10m 32 8ft Top View Vista a rea Vue de dessus 28 31 6m 19 7ft 4m 13 1ft 2m 6 6ft 0 2m 6 6ft 4m 13 11t 6m 19 7ft 8m 26 3ft 10m 32 8ft 11m 36 1ft Side View Vista lateral Vue de c t Figure Figura 3 Wiring Cableado C blage a N O N C COM A Alarm relay N O DG75C only Rel de Alarma N A S lo el DG75C Relais d alarme N O DG75C seul B Power input 12Vdc Alimentaci n 12Vcc Alimentation 12 Vc c C Anti tamper switch Interruptor antisabotaje Interrupteur de s curit re 10 O el o Optional Optionnel Opcional N O contact Contact N O Contacto N A Figure Figura 4 PCB Overview Vista General Vue d ensemble 1 Electrical connectors Conectadores el ctricos Raccordements lectriques 2 Anti tamper switch Interruptor antisabotaje Interrupteur de s curit 3 PCB height adjustment screw Tornillo de ajuste de altura de la placa de circuito impreso Vis d ajustement de la hauteur de la carte de LED circuits imprim s SHLD 4 Detection LEDs DUAL LEDs de Detecci n E DEL de d tection B a 5 Jumpers hs Ho mid Puentes bo Cavaliers 0 6 Sensors ES Sensores Correct Incorrect Capteurs Correcto Incorrecto Table Tableau Tabla 1 Jumper Settings Ajuste de los Puentes
20. uvement num rique haute performance optiques doubles pour l int rieur Dot d une v ritable insensibilit aux animaux il permet un animal de moins de 40 kg 90 Ib de circuler librement dans un secteur prot g sans d clencher d alarme Installation Le DG75 peut tre install comme d tecteur de coin ou sur surface plane la hauteur d installation recommand e soit entre 2 1 m 7 pi et 2 7 m 9 pi 10 le DG75 offre une couverture enti re pour des distances de 1 5 m 5 pi 11 m 35 pi voir Figure 2 au verso S assurer que le r glage de la hauteur de la carte de circuits imprim s corresponde la hauteur r elle de l installation voir Figure 4 et Figure 5 au verso AVERTISSEMENT e Installer l unit en suivant les instructions suivantes sans quoi la performance du d tecteur pourrait tre compromise e viter d installer le d tecteur proximit des sources d interf rence suivantes surfaces r fl chissantes circulation d air provenant de dispositifs de ventilation ventilateurs fen tres sources de vapeur d eau ou de vapeur d huile sources de lumi re infrarouge et articles entra nant des variations de temp rature tels que les appareils de chauffage les r frig rateurs et les fours e S assurer que le lieu d installation ne pr sente pas d obstacles qui pourraient nuire au champ de vision du d tecteur e Des fausses alarmes peuvent tre caus es par des animaux domestiques grimp

Download Pdf Manuals

image

Related Search

Related Contents

Sony CDX1000RF User's Manual  AFE CT Traité de chimie thérapeutique  mod. teg-448ws 48 port gigabit websmart+4 slot mini gbic  CRS- An appraisal & demystification of the technical issues  Manual 2.0 Digital Field Controller  Prexiso G4/G5  Instrucciones - Reed Manufacturing Co.  Samsung 910MP 用户手册  POWER MIG 180C (CE)  Mode d`emploi HYDROMETTE COMPACT « S »  