Home

Installation Manual

image

Contents

1. EXCITO FXFCH17 C Pressure regulator Teflon tape Shut off valve Flexible tubing Installation manual ADV REG _K TAS0004 SEWBV1414 KTPE14W XI EXCITO ADV REG CR_K not included in the set Components are placed inside of filter housing 5 Connection Scheme for Aquafilter Excito f e I B B le Cold water 4 ETC G gt 2 to Multi Stage Water Filtration System KW Chrome plated adapter FT06 Shut off ball valve SEWBV1414 Pressure regulator ADV REG _K not included in the set Pressure regulator ADV REG_K must be installed in systems with capillary membrane Flexible Tubing Connections A Water inlet connection B Faucet connection 6 Connecting Flexible Tubing with Quick Connectors Type JG John Guest and QC Quick Connector Disconnecting Flexible Tubing 1 Remove safety clips from quick connector Fig 1 2 Press on the flange of quick connector Fig 2 3 Pull out flexible tubing Fig 3 Connecting Flexible Tubing 1 Insert flexible tubing 1 5 cm 0 6 in deep into the quick connector Fig 4 2 Insert safety clip Fig 5 6 1 Removing and Installing the Elbow in Quick Connector Removin
2. T Oddl V v T O3OIV v T OdOIV 4 r O a y 10 Cartridge Sets Aquafiter offers three sets of cartridges for Aquafilter EXCITO systems capillary membrane is sold separately 11 Replacement Cartridges NAME OF SET EXCITO CRT EXCITO CLR CRT EXCITO HF CRT CARTRIDGE 1 AIPRO 20MS AIPRO 20MS AIPRO 20MS CARTRIDGE2 AIPRO 1MS AIPRO3 L AIPRO 3 L CARTRDGE3 AKCROL AICRO L3 _AIFROL4 O Cartridge Type AIPRO 20MS AIPRO 1MS AIPRO 3 L x AICRO L3 AICRO L4 x TLCHF FP x Description Filtration Stages Longevity AIPRO 20MS Polypropylene cartridge removes sediments such as rust sand and suspended solids AIPRO 1MS Polypropylene cartridge removes sediments such as rust sand and suspended solids AIPRO 3 L Three layer cartridge Polypropylene foam removes sand rust and other suspended matters Conditioning media removes iron and iron derivative compounds lon exchange filtration media acts as water softener exchanges ions of calcium and magnesium into ions of sodium preventing scale build up AICRO L3 Granulated activated carbon cartridge made of the high grade activated coconut carbon It is designed to remove up to 99 of chlorine sediments and organic contaminants It also improves the taste and
3. During the installation remember about maintaining correct water flow direction water flow direction is indicated on a label placed on each replacement cartridge 10 Connect tubing with elbow outlet connector attached to cartridge AIPRO 20MS Connect tubing with elbow outlet connector attached to AIPRO L4 filter cartridge Proceed as follows 1 Ensure that filter cartridge is placed in accordance with the direction of system s water flow Correct direction of water flow is indicated on a label placed on each replacement cartridge 2 Insert tubing into outlet elbow connector attached to cartridge AIPRO 20MS correctly inserted tubing is mounted 1 5 cm deep inside elbow connector 3 Secure the connection with safety clip NOTE When pulling out the tubing use caution to prevent the tubing from damage Collapsing of the tubing may result in damage and future water leaks IMPORTANT NOTE Before the first use and after each cartridge replacement procedure the system should be flushed with 15 liters of water Next allow the system to standby for 5 6 hours to activate the filtration media After these procedures the water is ready for consumption To replacement hollow fiber membrane follow the above described procedure 12 3 Filter cartridge replacement General information Examine all connections carefully Before replacing the front panel connectflexible tubing t
4. aroma of water AICRO L4 Granulated activated carbon cartridge made of the high grade activated coconut carbon It is designed to remove up to 99 of chlorine sediments and organic contaminants In addition a special filtration media removes heavy metals such as lead nickel chromium and many others It also improves the taste and aroma of water TLCHF FP Capillary membrane removes microscopic bacteria in size of 0 02 micron and larger 4000 3 6 I _ 5000 6 12 depends on water quality and level of contamination Before the first use and after each cartridge replacement procedure the system should be flushed with 15 liters of water Next allow the system to standby for 5 6 hours to activate the filtration media After these procedures the water is ready for consumption IMPORTANT NOTE Used cartridges may not be returned 12 Filter cartridge replacement General information IMPORTANT NOTE Before removing flexible tubing and elbow remove safety clip and symmetrically push in the flange of quick connector After installing flexible tubing and installing the elbow remember to insert safety clip of the quick connector 1 qm NS Shut off water supply valve 3 Before replacing the membrane disconnect all flexible Unscrew the holding screw and remove front pan
5. ation or use of system System installation should be performed only in temperatures above 2 C 35 6 F IMPORTANT NOTE Before installing the system remove from the filter housing all components necessary for installation P 2 i 2 1 2 2 2 gt Unscrew flexible tubing from the shut off valve the adapter IMPORTANT NOTE Between the shut off valve and flexible tubing is a rubber gasket be sure not to lose it 3 4 Screw chrome plated adapter onto the shut off valve to Wind a few layers of Teflon Tape TAS0003 on shut off allow easy installation of SEWBV1414 valve and its easy valve adapter SEWBV1414 opening and closing IMPORTANT NOTE Remember to place rubber gaskets in between the connections Screw SEWBV1414 valve into chrome plated adapter FTO6 7 Connect flexible tubing of SEWBV1414 valve with system s water inlet IN red ring 7 1 System Installation Wall Faucet Connection Place the nut on flexible tubing and connect it with SEWBV1414 valve Next push the tubing all the way into the valve and tighten the nut IMPORTANT NOTE Manufacturer is not responsible for any damages that result from improper installation or use of system System installation should be performed only in temperatures above 2 C 35 6 F IMPORTANT NOTE Before installing the s
6. el of the tubing from the system inlet outlet system s housing 12 1 Filter cartridge replacement System equipped with quick connect type cartridges J Remove the elbows one from the water inlet of the first Unpin all cartridges together from the mounting clips cartridge one from the water outlet of the last cartridge IMPORTANT NOTE While removing the elbows be careful not to bend flexible tubing 3 4 Remove elbow from used AIPRO 20MS cartridge and Insert all replaced cartridges into mounting clips of the connectit with replacement cartridge AIPRO 20MS Repeat system s housing Make sure that AIPRO 20MS is first from this action to replace remaining cartridges the left IMPORTANT NOTE During cartridge installation IMPORTANT NOTE During cartridge installation remember to follow proper direction of water flow remember to follow proper direction of water flow indicated by an arrow oon cartridge label indicated by an arrow on cartridge label 5 IMPORTANT NOTE Before the first use and after each cartridge replacement procedure the system should be flushed with 15 liters of water Next allow the system to standby for 5 6 hours to activate the filtration media After these procedures the water is ready for consumption To replacement hollow fiber membrane follo
7. g elbow from cartridge 1 Remove safety clip from quick connector Fig 1 2 Press on the flange of quick connector and remove the elbow Fig 2 Installing the elbow into cartridge 1 Insert the elbow into quick connector to the point of resistance Fig 3 2 Insert safety clip Fig 4 a lt Fig 1 Fig 2 Fig 4 6 2 Instructions for connecting and disconnecting filter cartridge and elbow connector new filter cartridge with elbow connector Disconnecting elbow connector from filter cartridge 1 Remove safety clips from quick connector fig 1 2 Push quick connector s flange symmetrically and pull the tubing out fig 2 3 Unscrew inlet and outlet connectors from old filter cartridge fig 3 4 Remove old Teflon tape fig 4 5 Apply mutliply layers of new Telfon tape ensure that Telflon tape is winded in the opposite direction to the direction connector will be installed fig 5 Connecting elbow connector with filter cartridge 1 Screw the elbow connector back to new filter cartridge NOTE Do NOT remove elbow connector after the installation has been started Stopping and removing unscrewing the element may result in inadequate connection and water leak fig 6 CT e e Li Fig 4 Fig 5 7 System Installation Stage IMPORTANT NOTE Manufacturer is not responsible for any damages that result from improper install
8. ing in individual connectors do NOT withdraw unscrew them at any time This may result in connection damage and future water leaks Unscrew inlet and outlet connectors from AIPRO 20MS filter housing Apply several layers of Teflon tape to the connectors threads NOTE Use only Teflon tape do not use tow NOTE Apply Teflon tape in the opposite direction to the direction connectors willbe installed Connect tubing with elbow outlet connector attached to AIPRO 20MS filter cartridge Proceed as follows 1 Ensure that new filter cartridge is placed in accordance with the direction of system s water flow 2 Insert tubing into outlet elbow connector attached to cartridge AIPRO 20MS correctly inserted tubing is mounted 1 5 cm deep inside elbow connector 3 Secure the connection with safety clip NOTE Described procedure can be found on page 4 point 6 2 NOTE When pulling out the tubing use caution to prevent the tubing from damage Collapsing of the tubing may result in damage and future water leaks In order to complete installation of the remaining replacement cartridges repeat the procedures described in points 1 9 4 tt ow J h N Nb I x Place filter cartridge into mounting clips Install AIPRO 20MS in such way that the cartridge is placed on left side of the filtration system NOTE
9. o the system inlet outlet 3 Shutoff water supply valve With filter faucet in a closed position slowly open water supply valve and check for leaks 4 Disconnect flexible tubing from the system 5 6 Replace the front panel and screw it with the housing Connect flexible tubing to the system inlet outlet 7 IMPORTANT NOTE Before the first use and after each cartridge replacement procedure the system should be flushed with 15 liters of water Next allow the system to standby for 5 6 hours to activate the filtration media After these procedures the water is ready for consumption With filter faucet in an open position slowly open water supply valve
10. put on cover plate 2 and then rubber gasket 3 3 Secure the faucet in the drilled sink counter opening 4 Underneath the sink put the rubber 5 and metal 6 washers on the faucet extension 4 and tighten with metal nut 7 5 Install flexible tubing Supplying water and connecting faucet with the system put the tubing 11 through the metal nut 10 and plastic tightening ring 9 put the insert 8 into the tubing push flexible tubing all the way into the faucet extension 4 and tighten it by hand with the metal nut 10 6 Connect other end of flexible tubing with connector OUT white ring Fig 2 Fig 2 Connecting flexible tubing with OUT connector COUNTERTOP Fig 1 Installing filter faucet on kitchen counter 9 Cartridge Connection Scheme in Aquafilter EXCITO System WATER SUPPLY INLET a SLU SIN0 Oddl V SWL OddIV pS f T OHOIV v T OqOIV 9 1 Cartridge Connection Scheme set EXCITO CLR CRT WATER SUPPLY INLET m SIW0 OddIV T Oddl V PFOHOIV 9 2 Cartridge Connection Scheme set EXCITO HF CRT WATER SUPPLY INLET SWOd Odd IV
11. temperature RNS ae aos ae cs a be es hnscameed tated s anceeesateeeda eine unghie seereet nase selaa between 2 C and 23 C Water supply pressure 87 cane sea sexe quneiesaceyesseaheul AAA tnandsadtsasonseateequtate saspssasecscenete memonbesesiennetes 6 bar VWat ers upply adapt eru u a Matec sce u n ms ei case ne a eee E 1 2 Outlet tubing aa T E A a A dadidanieadiatannawaGtaiaiassees 1 4 Dimensions height x width x ge epth Sr Os Was a 390 mm x 355 mm x 100 mm IMPORTANT NOTE The system must be secured from high pressures and rapid pressure changes caused by local water supply systems Pressure regulator must be installed on the inlet of the system s water supply The system s optimal performance pressure is 3 5 bar pressure regulator must also be set to this parameter Failure to install pressure regulator will result in loss of warranty Regulator may be purchased separately catalog nr ADV REG_K ADV REG CR_K 4 Included in the Box Chrome plated adapter FT07 Cito 3 4 MIP x 3 4 FIP x 1 4 FIP 3 4 MIP x 3 4 FIP Chrome plated adapter sa Chrome 6 plated 4 2 MIP x 1 2 FIP x 1 4 FIP brak w zestawie dodatkowe wyposazenie Water filtration System Faucet ou _
12. w the above described procedure Connect the elbows one with the water inlet of the first cartridge one with the water outlet of the last cartridge YT a A A qr B lt gt Disconnect tubing from elbow inlet connector attached to Remove all filter cartridges out of mounting clips and the cartridge AIPRO 20MS system housing Disconnect tubing from elbow outlet connector attached to cartridge AICRO L4 Proceed as follows 1 remove safety clips 2 Symmetrically press quick connector s collar 3 Pull out the tubing NOTE Described procedure can be found on page 4 point 6 2 NOTE When pulling out the tubing use caution to prevent the tubing from damage Collapsing of the tubing may result in damage and future water leaks Disconnect tubing from elbow outlet connected to cartridge AICRO 20MS Proceed as follows 1 Remove safety clips 2 Symmetrically press quick connector s collar 3 Pull out the tubing NOTE Described procedure can be found on page 4 point 6 2 NOTE When pulling out the tubing use caution to prevent the tubing from damage Collapsing of the tubing may result in damage and future water leaks 5 Remove old Teflon tape out of the connectors thread surface Install screw in connectors into new filter cartridge NOTE During installing screw
13. www aquafilter com KK aqua filter The Clear Choice Water Filtration Systems Installation Manual 1 Safety Precautions m WARNING The system should not be used with biologically contaminated water or water of unknown origin Product may be installed only by trained service professionals Only original replacement parts filter cartridges and accessories made by manufacturer may be used Compliance with the following instructions ensures problem free product operation manufacturer s warranty Failure to comply with the following instructions will result in loss of warranty 1 The system is designed for the filtration of potable water only 2 Remember to remove safety clip before removing flexible tubing and elbow Only original Aquafilter replacement cartridges may be used Using cartridges made by other manufacturers results in a loss of warranty and relieves the manufacturer of responsibility for the incorrect operation of system 2 Product Description Aquafilter EXCITO is a modern filtration system designed for the purification of potable and general use water Equipped with four in line cartridges the system effectively removes rust sand and sediments cartridges AIPRO 20MS and AIPRO 1MS organic contaminants and chlorine cartridge AICRO L3 heavy metals such as lead arsenic cadmium as well as iron contents AICRO L4 3 Technical Specifications Inlet water
14. ystem remove from the filter housing all components necessary for installation Shut off water supply valve 3 m Screw chrome plated adapter FT07 onto the cold water pipe to allow easy installation of SEWBV1414 valve and its easy opening and closing IMPORTANT NOTE Remember to place rubber gaskets in between the connections 2 Unscrew the faucet from the wall 4 Wind a few layers of Teflon Tape TAS0003 on shut off valve adapter SEWBV 1414 N IN 7 lt N Screw SEWBV1414 valve into chrome plated adapter FT07 Screw chrome plated adapter FT02 onto the hot water pipe IMPORTANT NOTE Remember to place rubber gaskets in between the connections Connect flexible tubing of SEWBV1414 valve with system s water inlet IN red ring Place the nut on flexible tubing and connect it with SEWBV1414 valve Next push the tubing all the way into the valve and tighten the nut Screw the wall faucet to the installed adapters 8 System Installation Stage Il FXFCH5 FXFCH17 C Faucet Installation 1 Drilla 12 mm opening in a kitchen counter or kitchen sink in case of enamel sinks the manufacturer recommends drilling openings in the structure supporting sink 2 On threaded faucet extension 1 first