SI Series Sensor Indicator User Manual
Contents
1. L m q RS485 communication baud rate 9 6K 1 H o g RS485 communication meter address 0 255 Alarm function table Alarm output AL1 AL2 is independent with each other H Direct High limit E ADIT L Inverse Low limit Sa Light bar indication SI4 does not have light bar SI6 has 10 digit light bar SI7 amp SI8 has 15 digit light bar SI9 has 25 digit light bar The digit number of light bar depends on panel size Light bar displays how much percentage of the Full Scale the input signal value is The bright part of the light bar shows the percentage of input signal value Full Scale depends on the setting of FL1 and FH1 for example if FL1 is 50 FH1 is 1300 just like the measuring range of K type thermocouple the Full Scale is 1350 When the display value is 675 50 of light bar will light FL1 and FH1 can be freely set for same signal input the percentage will change if Full Scale is changed 8 Apperance amp Mounting Dimension Panel size Side face size Mounting size C D 0 5 A E G t HO f Zz IY SS B JE Foe n _ b e au m r a UB 0 1 KKSIE01 4 9 Connection Drawing SI4 SI7 is under improvement now the connection drawing for these two model may be changed in the future SI7 OUTI SI4 24V GND 4 20mA TC mV 0 10V or 4 20mA Ck bdd GHIO lofe 100 240 Vac Power COM OUTI P24 4 20mA GND 24V
2. Relay D 4 20mA current output S SSR to be ordered _ Dimension mm 4 48Wx48H 6 48Wx96H 7 72Wx72H 8 96Wx48H 9 96Wx96H SI Series Sensor Indicator 2 Model Indication Alarm no OUTI OUT2 Dimension mm Note OUT1 4 20mA current output load resistance 600Qmax OUT2 Relay output capacity 3A 230Vac Alarm Relay output capacity 1A 230Vac No No No No No 3 Main Technical Parameters 1 Whole controller parameters Power supply 100 240VAC lt 30mA 220VAC 0 50 C Ambient humidity 45 85 RH 2 Input signal table 0 kemeo soo re ossa Soe 6 Supetemecomie 101600 re assests Swe a e A A E a ET 2 KKSIE01 2 4 Panel indication PV Value or Parameter Code SV Value or Parameter Code ALI Indicating Lamp OUT2 Indicating Lamp SET Function Key BS OUT1 4 20mA current Indicating Lamp AL2 Indicating Lamp Communication Lamp Power Indicating Lamp Decrease Key 5 Panel Key Operation Increase Key PV Display Window Measuring Value Display Window To show the input signal value SV Display Window Setting Value Display Window To show the setting value ALI Alarm output indication light on alarm is on light off alarm is off AL2 Alarm output indication light on alarm is on light off alarm is off COMM Communication indicating lamp when it is flashing communication is working BS OUT1 4 20mA transmit current indicating lamp OUT2 Control output indi
3. OUTI INPUT SI6 SI8 SI9 ALI AL2 OUTI ALI Ar 4 20mA on COM o Power 24V GND 4 20mA 100 240Vac 24V GND4 20mA ag 100 240 Vac 0 10V 4 20mA 0 10V 4 20mA 10 Simple Problem Shooting Display Message Shooting Method Display HHHH Input disconnect or over upper limit please check input signal FH value and ambient working temperature Display LLLL Input disconnect or under lower limit please check input signal FL value and ambient working temperature KKSIE01 5
4. SI Series Sensor Indicator User Manual Features TC RTD Analog signal universal input selected by software menu With display and alarm function With optional RS485 communication function With light bar display function Good anti jamming Switching power supply 100 240VAC CrOLORC EC For your safe please read the below content carefully before you use the temperature controller m Safe Caution Please read the manual carefully before you use the temperature controller X Please comply with the below important points A Warning An accident may happen if the operation does not comply with the instruction A Notice An operation that does not comply with the instruction may lead to product damage X The instruction of the symbol in the manual is as below An accident danger may happen in a special condition 1 A safty protection equipment must be installed or please contact with us for the relative information if the product is used under the circumstance such as nuclear control medical treatment equipment automobile train airplane aviation and equipment etc Otherwise it may cause serious loss fire or person injury 2 A panel must be installed otherwise it may cause creepage leakage Do not touch wire connectors when the power is on otherwise you may get an electric shock 4 Do not dismantle or modify the product If you have to do so please contact with us first Otherwise it may cause electric shock
5. and fire 5 Please check the connection number while you connect the power supply wire or input signal otherwise it may cause fire 1 This product cannot be used outdoors Otherwise the working life of the product will become shorter or an electric shock accident may happen 2 When you connect wire to the power input connectors or signal input connectors the moment of the No 20 AWG 0 50 mm2 screw tweaked to the connector is 0 74n m 0 9n m Otherwise the connectors may be damaged or get fire 3 Please comply with the rated specification Otherwise it may cause electric shock or fire and damage the product 4 Do not use water or oil base cleaner to clean the product Otherwise it may cause electric shock or fire and damage the product 5 This product should be avoid working under the circumstance that is flammable explosive moist under sunshine heat radiation and vibration Otherwise it may cause explosion 6 In this unit it must not have dust or deposit otherwise it may cause fire or mechanical malfunction 7 Do not use gasoline chemical solvent to clean the cover of the product because such solvent can damage it Please use some soft cloth with water or alcohol to clean the plastic cover eS KKSIE01 1 1 Model SI OU OU O Ul Input amp Communication 10 One input without communication 18 One input with RS485 communication Please indicate when order Alarm function C Two alarm output Output function R
6. cating lamp light on output light off no output The on off of OUT2 is relevant to SV value SET Setting mode shift key parameter confirm key lt q Parameters change flashing key Vv Parameters change decrease key A Parameters change increase key 1 SET key In normal display status press SET key to show the setting menu press SET key for a few seconds to show advanced setting menu please refer to No 6 Operation Sequence 2 key press lt key to make the parameters to flicker the parameters can be changed 3 A V key to change parameters in setting status 4 In advanced setting menu press SET key for a few seconds to quit the menu and back to normal display status 6 Operation Sequence Alarm 1 value Alarm 1 hysteresis Alarm 1 mode Alarm 2 value Alarm 2 hysteresis Alarm 2 mode PV bias value Password lock Power on amp Reset SET Press SET gt 3 second Measuring status In normal measuring status press lt q key to make the SV value to flicker then press A and W to change the SV value Press SET key to confirm setting OUT2 is on off control output for SV value This function is similar to the on off control of temperature controllers but it does not have hysteresis setting OUT2 on off control is suitable to all signal input including TC RTD and analog signal mentioned in the Input signal table on page 2 OUTI is the transmit current output 4 20
7. mA It is optional function Users can set the brL and brH as lower and upper limit of transmit output Input signal selection Lower limit of display range Upper limit of display range Decimal point Not effective for TC RTD input Fliter constant The display value for 4mA current output The display value for 20mA current output Baud rate Meter communication address KKSIE01 3 7 Menu o i Ex f Parameter mdan Setting X actory name range setting m 1 Alarm 1 value FL FH 200 1 Aen ie m q Alarm mode L Inverse Low limit H Direct High limit m N m Alarm 2 value HOJ Alarm 2 hysteresis Op Alarm 1 mode L Inverse Low limit H Direct High limit Po ior Password lock If the units digit 4th digit from left to right is 1 SV is prohibited to changed LL if the tens digit 3rd digit is 1 menu parameters are prohibited to changed except for LCK menu nk Input signal type EL Lower display limit of input signal rH Upper display limit of input signal g L Display decimal point setting Only effective for linear voltage current and resistance input L Filter constant The bigger the value is the slower the display value changes The smaller the value is the faster the display value changes are The display value for lower limit of transmit current output Please refer to the input signal table olga The display value for upper limit of transmit current output on page 2