Home
Installation Manual
Contents
1. 0m 2m 4m 6m 8m 10m 12m Om 2m 4m 6m 8m 10m 12m Position 2m Coverage 0m 2m 4m 6m 8m 10m 12m 7 INS352 2 6 Coverage Area Bottom of head unit Bottom of head unit Vg 3015 0 15 30 s Top View wz wo wg Active Active detection detection coverage coverage Walk testing With the range sensitivity coverage and pulse count set as desired enable the LEDs and walk through the area of protection Confirm the LEDs light and alarm relay activates INS352 2 8 7 Auxiliary Input With the Auxiliary input enabled JP8 a second detector with a normally JPS closed relay output can be connected to the Prestige External detector to give directional detection The order of activation required to give an alarm signal is ON set by the direction jumper JP9 When this is set to 1st the auxiliary detector must be activated first followed by the Prestige External detector within 1 minute to give a valid alarm signal With the jumper set to 2nd the Prestige External detector must be activated OFF followed by the auxiliary detector within 1 minute If directional detection is not required disable the auxiliary input using JP8 Aux J U Prestige External PIR JP9 ALARM SAD st ALARM ALARH JP9 AUX B B Prestige External PIR 2nd M ALARM 1s
2. 02 EN 55022 Class B 9 Physical Specifications 89mm INS352 2 86 5mm lt gt 35 C 31 F to 60 C 140 F 6 IL 35 C 31 F to S D 55 C 131 F a Ww 550g 200z approx a Texecom www texe com Texecom Limited Bradwood Court St Crispin Way Haslingden Lancashire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at 3 36 pence per minute from a BT landline Calls from other networks may vary International Customers Tel 44 1278 686197 Email techsupport texe com Texecom Limited 2009 INS352 2 B20090720
3. CE Installation Manual Prestige External TD INS352 2 Texecom Designed to Perform 1 Accessing the Unit Q 2 Remove the top cap and loosen screw Push up head unit and remove screw retained in wall plate Use a flat head screwdriver to lever out both sides of the terminal cover as shown INS352 2 2 Choosing a Location e Mounting height 1 0 1 4m nominal 1 2m measured to middle of unit e Mount perpendicular to ground Parallel e Try to avoid direct sunlight Avoid pointing at swaying bushes trees and x a X swaying clothes on a clothes line BE n i ust Tee N ak e Try to install the detector so its detection area is terminated by building fences etc This will reduce the effect of range variation caused by environmental changes e In the detection area try to avoid reflective surfaces such as standing water swimming pools or polished floors as this can cause the detectors range or coverage to vary as reflected signals may be seen INS352 2 2 3 Mounting the Unit Front View fe WALL MOUNTING EED EN For wall mounting the D i cable should be brought l l through the wall into the cable entry hole G ey eae ee ea 7 a REAR TAMPER To enable the rear tamper the breakaway keyhole section must be securely fixed t
4. o the mounting surface Cable Entry Rear View SURFACE WIRING For surface wiring use the appropriate knockout in the le Ent eos Pape ety z N top or bottom of the unit If wiring from the top use the O knockouts in the top cap and run the cable down the cable channels and into the unit as shown Knockout in Top Cap Cable Channels Cable Entry Conduit Entry er 3 INS352 2 Pole Mount Bracket Mounting POLE MOUNTING Using the pole mount kit available separately the unit can be mounted on poles with an outside diameter of 20 57mm Assemble the kit around the pole as shown and tighten the 4 bolts Hook the detector wall plate onto the kit and secure the remaining 2 bolts through the lower mounting holes 20 44mm D 45 57mm D INS352 2 4 4 Wiring the Unit TERMINAL BLOCK 12V amp OV 9 16 Voc ALARM NO NC selectable relay output 18 Q 50Vbc 100mA Max TAMPER NC Relay output 18 Q 50Vpc 100mA Max elololelololololo RLED OV LED off 12V or No Connection LED on AUX NC relay input 12V OV ALARM TAMPER RLED AUX NC Normally Closed NO Normally Open JP1 Pul
5. se Count yn 4 0 3 3 0m s P 7 ad gt JP2 Sensitivity HIGH MEDIUM LOW JP3 Alarm NC alarm relay normally closed NO alarm relay normally open 5 INS352 2 E JP4 LED OT g JP5 MODE 5 i f D RA Day Night Mode Night Mode Detector is always operating Detector only operates at night JP6 amp JP7 END OF LINE JUMPERS 12V OV ALARM TAMPER RLED AUX ZIZIZIZIZIZIZlala BIR jeee Jz _ gt TT __ LF lt JP6 o the ae Selects the resistance across the alarm ne ates relay Equivalent to wiring a resistor of the ee d ai be selected value as shown shown ALARM JP7 TAMPER JP6 o c 2K2 1K0 bl 4K7 oy f 5K6 oy 1K0 b OY 5K6 e 000 0 000 0 JP8 amp JP9 see Auxiliary section page 9 INS352 2 6 5 Range Adjustment PIR Bottom of head unit To adjust the range of the detector rotate the circular section shown until the desired range is shown in the window Note Range can vary due to environmental conditions To reduce the risk of false alarms always select the lowest range possible for the installation Specified ranges are valid for nominal 1 2m mounting height Selected Range Side View Position 12m Coverage
6. t OS NO FAS ALARM NO ALARM Quality Assurance Warranty 2 year replacement warranty j he Prestige External unit is designed to detect the movement of n intruder and activate an alarm control panel As the Prestige o Wsia External unit is not a complete alarm system but only a part aris sect dst dissociation thereof Texecom cannot accept responsibility or liability for any wader damages whatsoever based on a claim that the Prestige External unit failed to function correctly Certificate Number FM 35285 MADE IN ENGLAND Due to our policy of continuous improvement Texecom reserves the right to change specification without prior notice All specifications are measured at 20 C 68 F The Prestige External detector is protected _ by UK amp International Designs Prestige is a Trademark of Texecom Ltd 9 INS352 2 8 Specifications Mounting Height Supply Voltage Current Drain typical Detection Method Range Alarm Output Tamper Detection Tamper Output LED Indication Environmental Protection Waterproof Coating EMC 1 0 1 4m 1 2m nominal 9 16 VDoc 28mA Dual non overlapping digital PIR 12m max Adjustable to 8m 5m and 2m NC NO selectable relay Rated 50Vpc 100mA 182 Wall and case Sealed non mechanical switch NC relay Rated 50Vpc 100mA 182 Red alarm indication IP65 Conformal EN 50130 4 1996 A1 1998 A2 20
Download Pdf Manuals
Related Search
Related Contents
Février / Mars 2014 - La-Ferté-sous Ficha Técnica Extraplas Naranja 2h PYLE Audio PRO PTA2 User's Manual O-Series DVR User Manual Recover It All Now – Documentation – SYBA SD-DAC63093 User Manual for Arcsource 6 Consultar manual de Instruções Manuel d`utilisation à l`usage du propriétaire d`une Oxyfix® G Copyright © All rights reserved.
Failed to retrieve file