1. FG 32 DDC pre release user guide V1 4 FG32 pre release user guide fi Bae zaas r r a r ee G a Lat al EEE ete BRED EEEIBR EE TIE EE a E FG 32 DDC pre release user guide V1 4 Document Change Log 01 Nov 2012 Document created 14 Nov 2012 Added new chapter for restoring FG32 back to default apps Added in new chapter for Changing IP address Jumpers setting diagram updated on page 8 Watchdog jumpers settings added FG 32 DDC pre release user guide V1 4 Table of Contents AOC COMM PEE A E P A E ade naesicendenwsdigstaamedoaneeqannesaaueaaveeet A E AE EE E 4 BS Ce a e EE A AI E A E E sans E T S A EA E 5 DEVICA SOC INCA LOIS aeren E A E E E E E EE E E A 5 DEVIC DT O E E E E E A E E E EA 6 mout Output CONT BUT ATION sorrera o E E E E 7 Jumper C one a ON ean E E E E N E TA E E E AES 8 Connecting to FG32 Sedona DDC via Sedona workbench ssesssssnssssssseeerssssrerrssserressssesesssseerssssserees 9 Install platform files and kits files 0nn a00nnnnnnnnsnnennnssseennsssssseenesssseerssssrrerssreeressssrreesssseesessseeserrssseeere 9 Loe DO CAINS a E S T E E sadn N 12 Troubles hod oerjaen era ER EREE N EEE EEE AE EEE EEEN IEOR 13 Checklist pOint Lg ectice gessees inn vdentsirnep gained sa qeateaes tassnnpooiteaitoomstaanetiendurasisae Ea Ann aeai ieina ri anini ana 13 CHE CKIISE POINT 2 serene E EEE ERR
2. Include in library Share with Mame A app sab 3 kits scode Step 5 Transfer the app sab and kit scode in to the FG32 mnt folder MNT folder is at the root of the FG32 directory Overwrite the existing files in the FG32 16 FG 32 DDC pre release user guide V1 4 EasylO C Users pel Desktop FG32 default apps n ef Download a Gi J easylO FG32 sedona files p easylO FG32 sedona files Norway E z J FG32 default apps me m Filesize Filetype Filename z Filesize Filetype 3 app sab 349 SAB File 3 app sab 349 SAB File 3B kits scode 38 504 SCODE File app sab bak 349 BAK File 5p fg config 69 XML Confi _ FGCal 56 405 File 3 kits scode 38 504 SCODE File _ kits scode bak 38 504 BAK File m svm exe 85 178 Application 11i r 2 files Total size 38 853 bytes 7 files Total size 219 358 bytes Step 6 After transfer is successful cycle power of the controller and re enable the watchdog jumpers refer page 8 Step 7 Connect to the FG32 via sedona workbench If above steps done correctly sedona workbench connection will be good 17 FG 32 DDC pre release user guide V1 4 EasylO Technical Support For technical support issues please contact technical support person as below Email support easyio com 18
3. 3 Jul 11 4 19 PM 23 Oct 12 9 58 AM 13 Jul 11 4 20 PM 13 Jul 11 4 20 PM 01 Nov 12 11 58 A m Computer My Data D Niagara Miagara 3 5 34 sedona Type File folder File folder File folder File folder File folder File folder File folder File folder File folder File folder File folder File folder For Niagara Ax 3 6 xx user Drag and drop it in to the sedona root folder Hit Yes on the pop up to merge the files n di gt Computer gt My Data D Niagara Niagara 3 6 31 1 1 26 5 sedonaBundles Sedona_Framework_Bundle_TXS 1 1 26 5 sedona gt hd Include in library v A Name adm J apps D bin d doc d jennic J kits J lib d manifests di platforms D src di temp provision B src zip 10 Share with v Burn New folder Date modified Type Size 02 Apr 12 2 49PM_ File folder 11 Jul 12 12 33PM File folder 11 Jul 12 10 56 AM File folder 02 Apr 12 2 49PM File folder 02 Apr 12 2 49PM__ File folder 01 Nov 12 9 23 AM File folder 02 Apr 12 2 49PM_ File folder 24 Oct 12 11 40 AM File folder 02 Apr 12 2 49PM File folder 02 Apr 12 2 49PM File folder 24 Jul 12 7 10 AM File folder 31 Oct 12 1 01 PM File folder 02 Dec 11 11 34 AM WinRAR ZIP archive 753 KB FG 32 DDC pre release user guide V1 4 Step 6 For Niagara Ax 3 7 xx user Drag and drop it in to the sedona root folder Hit Yes on the pop up to merge th
4. E E E EE EE ETNE E R 13 aene AE e SS E E E S E E E E E E E S S E E EE 14 Restoring FG32 back to default GODS sce ccssscncasesicnsaarnswsiiecnensuwsueas svedavdeasonsanedestauedasdvaeesnanaddeaduvadeauaveaivaavdevet 15 Te DMC UN OE n E EE E EEEE A E EE E E 18 TEP TE H FiFi LUULUII LEE EFFERIA TIT FF Eau FG 32 DDC pre release user guide V1 4 Introduction We are getting ready to release our new FG series of Controllers starting with the EasylOFG32 DDC controller product reference EasylO FG GC 32 It is equipped with two 32 bit Processors the first in the Automation industry with an ARM9 200 MHz Samsung processor an ARM M3 Cortex for the I O management and A D processing and also with a Linux 2 6 OS for premium performance Later in 2013 we will be adding Graphics capability to serve up html templates that will be stored on the Micro SD card BACnet and Modbus will also be added in 2013 TCOM is available now and is encouraged for premium performance with Niagara e The Build bootloader can now be carried out remotely No more manual service button needed is used e Firmware upgrading now can be done remotely and without any assistant e Firmware upgrading is via ftp client e In this user guide is just a pre release internal use user guide Note Information in this document is accurate at the time of documented Actual information may change defer without notice This document in only in
5. File amp KB Checklist point 2 2 additional kits are in the kits folder easyioFG and easyioFGDDC t sedona kits folder Name Date modified Type di easyioFG 17 Oct 12 9 28 AM File folder di easyioFGDDC 17 Oct 12 9 28 AM File folder Tez PPE PEP Gyad WTF ERT EEE Ss a PREETI TTTTTIT FF Eau FG 32 DDC pre release user guide V1 4 Changing IP address By default the controller IP address is at 192 168 10 11 Changing the IP address can only be done via sedona workbench at the moment Step 1 Login to the FG32 via sedona workbench Locate the object IP under the sedona service folder E 192 168 10 11 al Sedona EasvIOFG B app Service plat ag IP Users EasyIo Step 2 Go into the property sheet of the IP object IF feasyvioFG IPContig 3 Meta _ 4 Status Current Ip 4ddress ki 1668 10 11 255 255 255 0 Epa pale aaa o 192 168 10 1 l6s 1lo0 1 rrn 1686 10 11 255 255 255 0 255 255 0 192 168 10 1 l66 1l0 1 Step 3 Save the sedona apps and cycle power Current Subnet Mask I Current Gateway _ O New Ip amp ddress _ O New Subnet Mask _ New Gateway E 192 168 10 11 al Sedona EasyIOFG TIES ue Cry Copy iE Faste FA Faste Special oe Ee Step 4 Current IP address that is assign to the controlle
6. act ee 2 Digital Output 8 Channels Relay Contacts SPST NO 48VA at 24VAC Pilot Duty DO aaa SS eee 3 Universal Output 8 Channels 12 bits resolution Current 0 20mA 4 20mA up to 800 Ohm load Voltage 0 10V Open Collector Output Max Current Rating 0 3A Max swe amp 8 8 SRP FFL EGET FTE Pe FG 32 DDC pre release user guide V1 4 Jumper Configurations L Current j On EOL terminated E Uni EIA 485 Jumper niversa JT Voltage p Output Jumper settings i Off EOL Not terminated L EE Open Collector 7 D ee eee eee FO eeeteee d inara a dii Di 2 Watchdog p g yi 5 i gt Ne TT a e N EE Ta AE r Universal Input A TE Jumpers Settings Jumper Settings EE Resistance PRR A ET a a at C Watchdog enable mms T F Voltage W moer eem z a aun Watchdog disable mmm EE Prete mee Current FG 32 DDC pre release user guide V1 4 COO chs chsh eBshds8 282d cha 24342424 3 i5 CEEE EE a Connecting to FG32 Sedona DDC via Sedona workbench In order to connect to the new EasylO FG32 DDC some files are needed EasylO FG32 has a different sedona platform files and kits These kits are hardware dependent Follow the below instructions before connecting to the controller via Sedona Workbench Install platform files and kits files Step 1 Get the r
7. atus LED will blinks for fast for a few times then light up steady for approx 10 seconds If the above note happen follow the below steps to regain sedona connection Below steps can be use for restoring the FG32 to default apps as well Email to support easyio com to request for the FG32 default apps 15 ome FF CI EJ LJ J LJ J FET BELEE FG 32 DDC pre release user guide V1 4 Step 1 Refer to page 8 jumpers settings locate the watchdog jumpers settings Disable the watchdog by shorting pin 2 and 3 If the watchdog is disable the device should be able to run the ICMP command Ping Skip step 1 and step 2 if the controller is not in rebooting cycle mode Refer to above note for rebooting cycle mode Step 2 Power off the controller and let it discharge for about 5 seconds and power it up again The rebooting cycle will end The controller will boot up and the status LED will blink approx 2 blinks per second with a short pause Step 3 Open any ftp client software in this case filezilla Login details to FG32 build in FTP server as below IP address this is the last IP address that the FG32 had Default is at 192 168 10 11 Username root Password 1234 Port 21 Host 192 168 10 11 Username root Password oe Port 21 Step 4 Unzipped the backup file email by easylO tech support _ EN I i
8. e files gt Computer MyData D Niagara Niagara3 7 44 8 1 219 sedona gt ide k easylO FG32 sedona files Include in library Share with Burn New folder Include in library Share wit Name Date modified Type di kits Q1 Nov 123 12 PM File folder J manifest 03 Oct 1212 18 PM File folder platforms 14 Sep 12 10 30 AM File folder di platform di store 14 5ep 12 10 32 AM File folder Step 7 Re open workbench and connect to EasylO FG32 controller 11 ffi tL LE Se fF FG 32 DDC pre release user guide V1 4 Login Details EasylO FG32 details are as below Sedona Login Username admin Password lt no password gt Default IP address 192 168 10 11 Default Subnet 255 255 255 0 Default Gateway 0 0 0 0 Note In order to login the host PC laptop has to be in the same subnet Example IP address 192 168 10 123 Subnet 255 255 255 0 12 5 SO i 4 0 i FG 32 DDC pre release user guide V1 4 eR EEC E Gasul Troubleshoot In order to make sure all the files are copied correctly into the directory follow below checklist to verify all the files are in place Checklist point 1 Platform file is in the platform folder sedona platform db easyio fg r 1 0 45 20 par folder Mame Date modified Type Size di swm 24 Aug 12 3 30 PM File folder __ platformManifest xml 10 Oct 12 14 54 PM XML
9. equired files from easylO technical support at support easyio com Step 2 Close the workbench Open sedona folder in the Niagara installation directory Niagara Version Sedona directory Niagara Ax 3 5 xx Niagara niagara 3 5 xx sedona Niagara Ax 3 6 xx Niagara niagara 3 6 xx sedonaBundles sedona 1 1 xx sedona Niagara Ax 3 7 xx Niagara niagara 3 7 xx sedona Step 3 Copy and merge the 2 folders that obtain from easylO technical support The 2 folders are platform and kits For Niagara Ax 3 5 User go to step 4 For Niagara Ax 3 6 User go to step 5 For Niagara Ax 3 7User go to step 6 Include in library Share with Burn New folder Name Date modified Type Size di kits 0l Now 12 3 10 PM File folder di platform 01 Nov 12 3 11 PM File folder FG 32 DDC pre release user guide V1 4 Step 4 For Niagara Ax 3 5 xx user Drag and drop it in to the sedona root folder Hit Yes on the pop up to merge the files J easylO FG32 sedona files gt Include in library Step 5 Share wit Mame di adm di apps bin di doc W kits i lib di manifests di platforms di scode we Include in library di backup uncher Es temp provision Share with Burn New folder Date modified 13 Jul 11 4 19 PM 06 Sep 12 2 44 PM 31 Oct 12 4 39 PM 13 Jul 11 4 19 PM 13 Jul 11 4 19 PM 22 Oct 12 6 44 AM 08 Dec 11 12 05 PM 1
10. r New IP address field Keyin the requires IP address in these fields Make sure the IP address and subnet is correct before saving Save Hibernate Cit Restart Reboot Reconnect to the sedona via Sedona workbench with the new assigned IP address 14 ESF H P Fi FE 7 UGI TARILE EFFERIA EIRA FF Eau FG 32 DDC pre release user guide V1 4 Restoring FG32 back to default apps At the moment there are 2 ways to restore the sedona apps for FG32 controller The first way is where you could still gain access to the controller via sedona workbench By manually selecting all the objects and delete it The SAVE action is needed Then a reboot or restart of the VM will erase all the objects in the sedona apps The second way of restoring the FG32 back to default apps is via ftp client software This way can be use as well if the FG32 sedona VM is not connectable and the controller keep rebooting due to some incompatible sedona apps loaded When this happen the watchdog will kick in and will not allow the sedona VM to boot at all hence a rebooting cycle will occur Note A easylO 30P sedona apps CANNOT be loaded into the easyio FG32 as the sedona apps from a 30P backup is hardware dependent Doing so will corrupt the FG32 sedona VM and the controller will keep rebooting the sedona VM hence the controller is not accessible via Sedona Workbench If the rebooting cycle occurs the st
11. tended for the beta testing process We oo oo oo oo FTIT ae Ses za sa FG 32 DDC pre release user guide V1 4 Device Info a EasyIO FG32 Sedona series 32 I O Controller Device Specifications Mechanical es 233mm x 124mm x 44mm approx Electrical 10 to 95 relative humidity non condensing Communication Details of EIA 485 will TBC _ SAS PA ARACE EIA 485 BUS A B Two wire Half Duplex Port 1 Speed 9 6K 19 2k 38 4K 57 6K 115 2K bit s Data Bit 8 bits Mig DUD gue E g Parity None Even Odd Bacnet Baud Rate Speed 9 6K 19 2k 38 4K 76 8K Data Bit 8 bits Parity None Physical Interface 2 Port 2 EIA 485 BUS A B Two wire Half Duplex Speed 9 6K 19 2k 38 4K 57 6K 115 2K bit s Data Bit 8 bits a Parity None Even Odd Bacnet Baud Rate Speed 9 6K 19 2k 38 4K 76 8K Data Bit 8 bits Parity None Ethernet Support IP TCP UDP ICMP HTTP FTP Application Support Sedona at the moment and TCOM driver FG 32 DDC pre release user guide V1 4 Device Dimension Below are the dimensions for the EasylO FG32 Top View Width including connectors are approx 124mm Side view and back view Improve DIN rail mounting for easy dismantling FG 32 DDC pre release user guide V1 4 Input Output Configurations Univeral input i6Chamnels SSS UI as Digital Input Voltage Free Cont