788CHNTC Installation Manual (79040194).indd

image

Contents

1. bulbs WHITE receptacle in fan 7 Place washers and glass housing shade over mounting 4 Attach grille pan to rod and align shade over mounting brackets with grille pan Secure shade 2 screws included to grille pan with washer S Thread rod onto and finial nut as shown threaded stud in center 8 Restore electrical power of grille pan Tighten rod and check operation of securely the unit Nulone USE AND CARE WARNING DISCONNECT ELECTRICAL POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE CLEANING OR SERVICING THIS UNIT BULB REPLACEMENT Remove glass shade Replace bulbs as required Reinstall glass shade Use 13 watt maximum GU24 type fluorescent bulbs with a M O L Maximum Overall Length of 4 8 inches or less MOTOR LUBRICATION The motor is permanently lubricated Do not oil or disassemble motor MODEL 788CHNTC Page 4 USE AND CARE CLEANING TO CLEAN GLASS SHADE AND GRILLE PAN Remove glass shade Shade can be wiped clean with a mild detergent solution or glass cleaner and dried with a soft cloth Remove 2 bulbs Grille pan may be gently vacuumed and wiped clean with a soft cloth Never use abrasive cloth steel wool pads or scouring powders on glass shade or grille pan METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER TO CLEAN FAN ASSEMBLY Remove grille pan and unplug fan assembly BLACK receptacle Gently vacuum fan motor and interior of housing METAL AND ELECTRICAL PARTS S
2. in direct contact with fan light housing per UL Underwriters Laboratories standards The slightest backdraft however will close the damper flap preventing air from entering unit or finished space MOUNTING SCREWS 1 Connect 4 round duct to damper duct connector and extend duct to outside through a roof or wall cap Check damper to make sure that it opens freely Tape all duct connections to make them secure and air tight CONNECT THE WIRING SCHEMATIC WIRING DIAGRAM LIGHT LIGHT SWITCH I WHITE BLK BLK VENT WHT BLACK meee RED BLACK GROUND RECEPTACLE bare WHITE RECEPTACLE DUAL CONTROL LIGHT purchase separately 120 VAC LINE IN 1 Wire unit as shown Re install wiring plate removed in Step 2 under PREPARE THE HOUSING 2 Run electrical cable as direct as possible to unit Do not allow cable to touch sides or top of unit after installation is complete MODEL 788CHNTC Page 3 FINISH THE INSTALLATION 2 Attach grille pan mounting brackets to housing with screws included Make sure brackets face inward 1 Re install blower assembly removed in Step 1 under PREPARE THE HOUSING Plug blower into BLACK receptacle WASHER FELT lt lt XS WASHERS I FINIAL FELT t NUT WASHER A 3 Locate grille pan 6 Install bulbs Use 13 watt over fan housing and maximum GU24 type connect light plug into fluorescent
3. AIRS In order to ensure your unit remains in good working condition you must use Broan NuTone genuine replacement parts only Broan NuTone genuine replacement parts are specially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit which will result in premature failing Broan NuTone also recommends to contact a Broan NuTone certified service depot for all replacement parts and repairs 79040194A
4. CHNTC Page 2 INSTALL THE HOUSING New Construction 1 Choose the location for your fan light in the ceiling For best possible performance use the shortest possible duct run and a minimum number of elbows BOTTOM EDGE OF JOIST MOUNTING SCREWS 2 Position fan housing against joist so that bottom edge of housing will be flush with finished ceiling Additional positioning feature for 1 2 thick ceiling material Bend two tabs on side of housing 90 outward Lift housing until tabs contact bottom edge of joist 3 Use 4 mounting screws included to attach housing to joist Existing Construction 1 Choose the location for your fan light in the ceiling For best possible performance use the shortest possible duct run and a minimum number of elbows 2 In attic position fan housing against joist Trace outline of housing on ceiling material 3 Set housing aside and cut ceiling opening slightly larger than marked Nulone SEAL BETWEEN CEILING MATERIAL amp HOUSING 4 Place housing in opening so that its bottom edge is flush with finished ceiling Screw housing to joist through holes in housing as shown 5 Seal between ceiling material and housing to prevent air leakage INSTALL THE DUCTWORK NOTE The duct connector has a counter balanced damper flap The flap will be open approx 1 when duct connector is attached to housing This design permits insulation to be
5. HOULD NEVER BE IMMERSED IN WATER SERVICE PARTS 99526716 97018649 99271452 97018749 99160441 97018781 97018750 97018804 97018729 97018717 Glass Shade Shade Mounting Hardware Lamp 13 W GU24 Type Fluorescent 2 req Blower Assembly includes key no 5 3 req Screw Motor no 8 32 x 275 3 req Grille Bracket Assembly Wire Panel Assembly Damper Duct Connector Housing Assembly Light Fixture Assembly includes key nos 1 2 amp B Grille Pan Assembly Does not include key no 3 oJ FroOOoONDUBKRW PO 97018748 Order replacement parts by PART NO not by KEY NO WARRANTY BROAN NUTONE CANADA INC ONE YEAR LIMITED WARRANTY Broan Nulone Canada warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one 1 year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan Nulone Canada will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES BULBS OR BATTERIES FILTERS DUST ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance a
6. Nulone DECORATIVE VENTILATION FAN WITH LIGHT MODEL 788CHNTC Page 1 Register your product online at www nutone ca READ AND SAVE THESE INSTRUCTIONS WARNING A TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installationworkandelectrical wiring mustbe done by a qualified person s in accordance with all applicable codes and standards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhaust ing of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidd
7. USS Kr 0 1 Dl ed GRILLE EIGHIESH ARE LIGHT SHADE HOUSING MOUNTED HOUSING MOUNTED DIRECTLY TO JOIST TO 2 x 4 TRUSS 2 x 6 or larger Discharge parallel to joists Discharge parallel to joists ADDITIONAL FRAMING lt lt HOUSING J l i JOIST J CEILING MATERIAL JOIST GRILLE GLASS LIGHT SHADE PAN HOUSING MOUNTED TO I JOIST Requires additional framing for mounting Discharge parallel to joists Additional framing must be a 2 x 6 minimum height at least 9 inches long PLAN THE INSTALLATION INSULATION Place around and over fan housing ROOF CAP FAN with built in HOUSING PN damper we aa A a ORF O77 NRS Teh BU SNS ous LEY iss SSN EES f i gt AALA hi 9 FSNL IRD Sa i EAN L VEREIN D SONNA AAP SS D Se OS q SS SS tax WSs N SRY KLA Ss ey EES JY AAY ANN SAN gt Keep duct runs short as B TA 9 SAK N E a D a WA WSs M Shem CAP ii with built in damper M Ys Nos S N A Seal gaps around housing 4 IN ROUND DUCT Seal duct Purchase joints with 4 IN RO separately tape ELBO Nulone PREPARE THE HOUSING 1 Unplug blower and remove 3 screws securing blower assembly to housing 2 Remove blower assembly from housing and set blower assembly aside 3 Remove wiring plate from housing and set plate aside MODEL 788
8. en utilities Ducted fans must always be vented to the outdoors Do not install in a tub or shower enclosure Not for use in kitchens This unit must be grounded 10 This unit is U L listed Type C inherently protected 11 When applicable local regulations comprise more restrictive installation and or certification requirements the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses 12 When performing installation servicing or cleaning this unit it is recommended to wear safety glasses and gloves CAUTION A 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in FLAT CEILINGS ONLY Do not mount this product in a wall 3 The light fixture assembly must be mounted to the fan housing assembly included with this product Do not mount the light fixture assembly to a wiring outlet box 4 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 5 Please read specification label on product for further information and requirements Installer Leave this manual with the homeowner Homeowner Use and Care information on page 4 O1 CO 0 N O TYPICAL INSTALLATIONS Sea 2 x 4 2 x 4 CEILING CEILING CEILING JOIST or JOIST or JOIST L TRUSS L TR
9. nd service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone Canada or an authorized representative faulty installation or installation contrary to recommended installation instructions The duration of an implied warranty is limited to the one year period as specified for the express warranty BROAN NUTONE CANADA S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE CANADA S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE CANADA SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone Canada at the address or telephone number stated below b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date IF YOU NEED ASSISTANCE OR SERVICE For the location of your nearest Broan NuTone Canada Inc dealer Dial Toll Free 1 888 882 7626 Please be prepared to provide e Product model number Date and proof of purchase e The nature of the difficulty Broan NuTone Canada Inc 1140 Tristar Drive Mississauga Ontario LoT 1H9 Released February 2013 REPLACEMENT PARTS AND REP

Download Pdf Manuals

image

Related Search

Related Contents

Spool Converter User Guide  取扱説明書(PDF:338KB)  Owner/User Manual  Sony ICS-SP20 Marketing Specifications  "Electrophoresis and Immunoblotting". In: Current Protocols in Cell  a resiliência em resposta à pobreza    FSP 150SP-100 R6.1.1..  取扱説明書 - ロジテック  American Standard Princeton 2392.202 ICH User's Manual  