1. OPURA This filter traps any large particles that may damage unit A clean filter will ensure that OPURA performs as intended If aerator must be re assembled use the following schematic for assembly Note incorrect assembly of aerator components will result in lack of ozone production
2. WARNINGS AND CAUTIONS READ AND FOLLOW INSTRUCTIONS CAREFULLY FOLLOW ALL WARNINGS AND CAUTIONS IMPROPER USE OF OPURA MAY LEAD TO ACCIDENT AND OR BODILY INJURY G3 WARNINGS DO NOT OPEN REPAIR OR TAMPER WITH OPURA OPURA IS PACKAGED WITH A TAMPER PROOF SEAL WARRANTY IS NULL AND VOID IF THE SEAL HAS BEEN BROKEN DO NOT TOUCH OPURA WITH WET HANDS DO NOT ALLOW ANY ITEM TO REST OR PRESS AGAINST THE POWER CORD DO NOT USE OPURA IF THE POWER CORD HAS BEEN FRAYED OR OTHERWISE DAMAGED ENSURE THAT OPURA IS TURNED OFF AND UNPLUGGED FOR MAINTENANCE OR WHEN RELOCATING USE OPURA IN A WELLVENTILATED AREA A CAUTIONS KEEP AWAY FROM DIRECT SUNLIGHT DO NOT PLACE NEAR HEAT DO NOT BLOCK AIR INTAKE WHEN MOUNTING OPURA ENSURE THAT IT IS INSTALLED ON SOLID WALL TO AVOID DAMAGE TO UNIT OR USER WARRANTY OPURA is covered by a one year limited warranty WHAT IS COVERED BY LIMITED WARRANTY This limited warranty covers defects in materials and workmanship for your OPURA product WHAT IS NOT COVERED BY THIS LIMITED WARRANTY This limited warranty does not cover e Problems that result from e External causes such as accident abuse misuse or problems with electrical power e Servicing not authorized by O INNOVATIONS INC e Tampering with OPURA including any unit that does not bear a complete tamper resistant seal e Usage that is not in accordance with product instructions e Failure to follow the product instructions
3. button to toggle ozone concentration moving yellow LED within indicator strip Pressing POWER button will cycle through various ozone concentration levels Stop when desired ozone concentration level is obtained USE OF OPURA OPURA is a fully automatic unit sensing water flow and producing ozone on demand During water flow red LED at bottom of indicator strip will turn green Indicator strip will display water flow sensed from first yellow LED up to fifth Green LED indicates ozone production INSUFFICIENT WATER FLOW When water flow is insufficient for ozone production red LED will flash Increase water flow to correct problem If during normal water flow this occurs remove aerator and clean properly removing any blockage Reinstall and try unit again LOW WATER FLOW Green LED indicator will be lit and yellow LED will light in first position only indicating adequate but low water flow with ozone production HIGH WATER FLOW Green LED indicator will light in fifth position only indicating the highest water flow with ozone production CARE amp MAINTENANCE OPURA is virtually maintenance free However the following steps should be performed on a regular basis Use a clean cloth to wipe surface of OPURA and remove any dust or debris 2 Ona monthly basis clean OPURA aerator to prevent blockage Inspect aerator for dirt or debris and run under clean water to remove contaminants 3 Onan annual basis replace air filter on back of
4. e a clean flat surface within I5 feet of an electrical outlet OPURA should be mounted at least 6 inches 15 cm above faucet spout to ensure adequate flow of ozone gas 3 Remove mounting package e from OPURA box Select mounting hardware to be used For smooth surfaces such as tile Velcro mounting strips are recommended Use enclosed screw or nail for mounting on walls 4 a Mounting with nail screws Locate spot where nail screw is to be installed For nail installation use hammer and install nail into wall Ensure that nail extends approximately 0 25 inches 0 6mm to allow hanging of OPURA For screw installation drill small hole in wall and insert plastic anchor Ensure anchor is firmly placed in hole Secure screw to wall leaving approximately 0 25 inches 0 6mm to allow hanging of OPURA b Mounting with Velcro Mount Velcro strips on back of OPURA horizontally to ensure adequate contact with wall surface Peel off protective backing on one side only to expose adhesive Attach to back of OPURA as show in figure 4b Once attached to back of OPURA peel off remaining backing and push to wall in selected location Remove from wall and ensure that Velcro is securely attached to wall and unit surfaces 5 Connect silicone tube to bottom of OPURA 6 Hang OPURA on wall using nail screw or Velcro strips previously installed 7 Remove existing aerator from faucet 8 a If spout end is threaded male Install OPURA aerator on the fa
5. or failure to perform preventive maintenance e Problems caused by using accessories parts or components not supplied by O INNOVATIONS INC e Products with missing or altered serial numbers e Products for which O INNOVATIONS has not received payment Additional conditions may apply See www opura ca for details D O3Sinnovations 7548 C te de Liesse Montreal Qu bec H4T 1E7 T 514 336 9191 800 750 3870 F 514 745 2959 OPURA Model OP 1107 USER MANUAL OPURA CONTENTS ang OPURA handwash and hard surface sanitizer Faucet aerator with adapter 1 Universal spout adapter 1 Silicone tubing Mounting package I consisting of e Mounting nail screw and anchor e Tie wraps 5 e Wire mounts 3 e Velcro mounting strips 2 AC adapter 1 Spare filters 2 User manual 1 PRODUCT SPECIFICATIONS Model OPURA OP 107 Colour Silver Operating temperature Input voltage Power consumption Dimensions Gross weight 32 120 degrees Fahrenheit 0 50 degrees Celsius DC 12V 6W max 6 L x 4 5 W x 2 8 D in 152 x 115 x 73 mm 13 4 oz 380g Ozone output gas 40 150 mg hr Ozone concentration 0 14 0 50 ppm aqueous Protection 10 minutes auto shutoff with reset INSTALLATION AND SETUP Inspect OPURA box against parts list to ensure that package contents are complete 2 Select an adequate location to mount OPURA on wall above faucet on which OPURA will be installed Location should b
6. ucet spout and ensure it is securely in place Insert silicone tube to aerator b If spout end is threaded female Add enclosed adapter to OPURA aerator and ensure is it secured Take OPURA aerator with adapter and install on faucet spout Insert silicone tube to aerator c If spout has no thread Select the universal adapter and loosen all screws Mount firmly to spout end and tighten all screws equally Install aerator to universal adapter Insert silicone tube to aerator 9 Connect silicone tube to bottom of OPURA unit A WARNING ensure that the silicone tube is not compressed and is free of kinks when installed 10 Plug AC adapter end into OPURA and power adapter end into wall outlet Il Press and hold POWER button OPURA will respond with a beep and will light up indicating it is ready for use OPURA HAS BEEN FACTORY SET AT MEDIUM LEVEL 100 mg hr OF OZONE PRODUCTION FOR 0 3ppm CONCENTRATION OPERATION POWER ON STANDBY MODE Press power button and hold for one second until OPURA turns on OPURA will beep and indicator will display red LED at bottom Yellow LED indicator within indicator strip indicates level of ozone to be produced factory set at medium 0 3ppm POWER OFF Press and hold power button until OPURA turns off All lights will extinguish AQUEOUS OZONE CONCENTRATION SETUP OPURA is factory set to produce ozone at a medium concentration of 100 mg hr or 0 3ppm While OPURA is on press and release POWER
Download Pdf Manuals
Related Search
Related Contents
Leviton R02-IPHS5-0LW Instructions / Assembly Samsung GT-C3010 Uživatelská přiručka SeroCP™ IgG - Savyon Diagnostics Ltd Cooper Lighting Portfolio M8605 User's Manual HP Pavilion 17-f235nr MANUAL DE INSTRUCCIONES MF Cables Direct RB-334 power cable ITALIANO Precauzioni sulla sicurezza Questo termometro 20” Color TFT LCD Monitor User's Manual Copyright © All rights reserved.