Home
642 LCD Keypad : User Manual
Contents
1. Esprit is a trademark of Paradox Security Systems 2002 Paradox Security Systems Esprit 642 LCD Keypad 39 Notes 40 User s Manual P A RA D O Xx SECURITY SYSTEMS 780 Boul Industriel St Eustache Montr al Qu bec Canada J7R 5V3 Fax 450 491 2313 www paradox ca Printed in Canada 02 2002 642 EU00
2. How Do I Stay Arm the System 1 Press the stay key The display will read ENTER CODE TO STAY ARA SYSTEM 2 Enter your access code The display will read SYSTEM IN EXIT The light will flash followed by a confirmation beep The display will read STAY ARMED Esprit 642 LCD Keypad 13 3 4 ONE TOUCH ARMING One Touch arming enables you to arm the system using a single key without using an access code These features must be enabled by your installer 3 4 1 Once Touch Regular Arming This method will arm all zones in the system How Do I Regular Arm With the light on Press and hold the arm key The keypad will emit a confirmation beep and display SYSTEM IN EXIT The light will flash followed by a confirmation beep The display will read FULL ARMED 3 4 2 One Touch Stay Arming Refer to Stay Arming on page 13 for a full explanation of this feature How Do I Stay Arm Press and hold the stay key This will automatically Stay arm the system After the exit delay the display will read STAY ARMED 14 User s Manual 3 5 FAST EXIT This feature enables you to leave a perimeter that is already armed in Stay mode and have the system rearm itself You can set the system to rearm itself into one of two modes Stay mode or Regular mode The system will arm after the exit delay has expired How Do Rearm in Stay Arming Mode 1 With the system already Stay armed pres
3. a fire may be wasted unless the family has planned in advance for a rapid exit from their residence Plan and practice for fire conditions with the focus on rapid exit from the residence Drills should be held so that family members know what to do Each person should plan an alternative escape route such as a bedroom window should the bedroom doorway become inaccessible 9 3 PROVISION FOR THE DISABLED In special circumstances where the life and safety of certain occupant s depends upon prompt rescue by others the fire system includes a means of prompt automatic notification to those who are to be depended upon for the rescue Esprit 642 LCD Keypad 33 10 0 TESTING YOUR SYSTEM It is recommended that your system be tested once a week Contact your monitoring station BEFORE and AFTER testing How Do Test the System With the system disarmed and the light on 1 Walk in protected areas to activate motion detectors The display should read ZONE OPEN 2 Open and close protected doors and windows The display should read ZONE OPEN Your installer can advise you of the best way to test your particular system 10 1 FIRE ALARM TESTING Do not use flame or burning materials to test your fire detection devices Contact your alarm installer for safe methods to test your system 10 2 SYSTEM MAINTENANCE Under normal use you system requires no maintenance other than regular testing It is recommended that
4. both systems dual area or are not given assignment common area A zone belonging to a dual area is armed if either System A or System B is armed and disarmed only when both systems are disarmed A zone belonging to a common area is armed only when both systems are armed and disarmed if System A or System B is disarmed 18 User s Manual The installer must program the required access code definitions These definitions determine which access codes can arm System A as well as which codes can arm System B Codes can also be given access to both systems 3 10 3 Arming Both Systems Simultaneously If your code has access to both systems How Do Arm Systems A and B Simultaneously Enter your access code The 2 light will begin to flash and the exit timer will begin to countdown The display will read A B ARMED 3 10 4 Arming System A and B Separately If your Access Code has access to System A How Do I Arm System A 1 Press the stay key 2 Enter your Access Code The will flash and the exit timer will begin to countdown The display will read SYSTEM IN EXIT After the exit delay the display will read A ARMED Esprit 642 LCD Keypad 19 If your Access Code has access to System B How Do Arm System B 1 Press the Force key 2 Enter your Access Code The will flash and the exit timer will begin to countdown The display will read SYSTEM IN EXIT After the exit delay
5. executed and displayed through the keypad We recommend that you read this manual thoroughly and have your installer explain basic system operation to you 1 1 CONVENTIONS USED IN THIS BOOK Throughout this book there are icons to represent points of interest The following are used Vi to indicate notes or reminders to indicate a warning or caution Esprit 642 LCD Keypad 3 to indicate a tip KEY to indicate a button on the keypad 1 2 BASIC OPERATION Many of the features in your system must be enabled by your installer If the feature is not programmed the keypad will emit a rejection beep and the action will be canceled 1 3 KEYPAD INDICATOR LIGHTS The state of each light on the Esprit 642 keypad represents a specific condition in your system as shown in Figure1 1 Figure 1 1 Keypad Indicator Lights Ready Green ON Zone s closed OFF Zone s open FLASH During exit delay Q0 C Arm Red ON System armed OFF System disarmed FAST FLASH Alarm O0 9090 4 User s Manual 1 4 VISUAL FEEDBACK Everything you need to know about your security system is displayed on the Esprit 642 keypad The zones in your security system are immediately identified and important messages regarding system status appear right in front of you If zone status is normal the LCD display will read 58 5T E READY If any zones are open the display will read ZONE OPEN The display automatically sho
6. key to toggle the status of the selected zone bypassed or unbypassed 5 Return to step 3 to select other zones 6 Press the ENTER key to save and exit or press the CLEAR key to exit without saving 16 User s Manual You may also toggle the status of a zone by entering e the 2 digit number of the selected zone 3 8 BYPASS RECALL Use the Bypass Recall feature to bypass the same zones that were bypassed previously at the touch of a button How Do I Enable the Bypass Recall Function 1 Press the BvP key 2 Enter your access code The display will read ENTER ZONE L 1 TO BYPASS 3 Press the BvP key 4 Press the ENTER key to confirm your entry 3 9 FORCE ARMING Force arming enables you to rapidly arm the system without waiting for all the zones in the system to close Force arming is commonly used when a motion detector is protecting the area occupied by a keypad Esprit 642 LCD Keypad 17 How Do I Force Arm the System 1 Press the Force key The display will read ENTER CODE TO FORCE RRA SYSTEM 2 Enter your access code The display will read SYSTEM IN EXIT The light will flash indicating the exit delay After the exit delay the display will read FORCE ARMED The fire zone cannot be force armed 3 10 ARMING A PARTITIONED SYSTEM Zones can be divided into two systems Based on your requirements the installer designates which zones belong to System A or System B
7. the system How Do I Access the Trouble Display 1 Press the TRBL key 2 Use the A or V keys to view the trouble s See the corresponding explanation from the Trouble List If no repair instructions are given call your Security Company for repairs 3 Press the cLEAR key to erase troubles in memory and exit Trouble List No Battery Low battery If the battery is not connected to the panel the display will read TROUBLE O1 BATTERY FAILURE The battery connected to the panel should be replaced because it can no longer provide adequate backup current in the event of a power failure 30 User s Manual Power Failure If AC power is not being supplied to the control panel and or the power supply is unable to charge the battery The LCD display will read TROUBLE Ge POWER SUPPLY Bell Disconnect If a bell or siren is not connected to the bell siren output TROUBLE DH NO BELL appears in the display Timer Loss If the system timer is not functioning usually after a total battery and AC power failure the LCD display reads TROUBLE 08 TIMER LOSS The timer should be reprogrammed after total power loss See Key access programming on page 28 Tamper Zone Wiring Failure Indicates that there is a wiring problem in a protected zone The LCD display willread TROUBLE 09 ZONE WIRING FRULT Telephone Line Monitor If the panel detects telephone line loss the LCD display will read TROUBLE IO TELEPHONE LI
8. Code or User Code 01 in order to create access codes The display will read PROGRAMMING MODE SECTION 3 Enter a two digit code number 00 to 48 The display willread PROGRAMMING IN PROCESS This message remains until you have entered a valid access code 4 Enter a four or six digit access code A valid entry will returnthe PROGRAMMING MODE SECTION message 5 Return to step 3 to include additional entries or press CLEAR to exit 10 User s Manual 2 1 DELETING AN ACCESS CODE How Do I Delete an Access Code 1 Press the ENTER key The display will briefly read ENTER CODE TO PROGRAMMING MODE 2 Enter the Master Code or User Code 01 in order to delete access codes The display will read PROGRAMMING MODE SECTION 3 Enter the code number you wish to delete 00 48 The display will read PROGRAMMING IN PROCESS 4 Press the 2Np key and then the ENTER key This will delete the code The display will read PROGRAMMING MODE SECTION 5 Return to step 3 to delete additional entries or press CLEAR to exit access code is available does not contain The display will read NENE to indicate that an information 2 2 DURESS CODE The last user code code number 48 can be programmed as a Duress code If you are forced to arm or disarm your system under threat you can enter this access code to produce a silent alarm at the monitoring station Check with your installer to see if this option is enable
9. For security reasons write only user names and not actual access codes Other information This alarm system was installed on By Service is provided by Telit Your monitoring station s number is Your account number is Your alarm transformer location is and is on circuiti 38 User s Manual Warranty The Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year Except as specifically stated herein express or implied warranties whatsoever statutory or otherwise including without limitation any implied warranty of merchantability and fitness for a particular purpose are expressly excluded Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited to repairing or replacing at the Seller s option any product not meeting the specifications In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any other party caused by defective goods or otherwise arising from the improper incorrect or otherwise faulty installation or use of the merchandise sold
10. MESPRIT 4 642 LCD Keypad MESPRIT ds User Manual P A RA D O L SECURITY SYSTEMS TABLE OF CONTENTS TABLE OF CONTENTS ss 1 INTRODUCTION sin 4 Conventions Used in this Book sses 4 Basic Operation ear 5 Keypad Indicator Lights 5 Visual Feedback esee 6 Auditory Feedback AAA 7 Alarm Memory Display 7 Events rne Ln ete tees 8 Info List rsss RENE antenna 9 PartitlOning Aires ne wiles ae eite ene 9 ACCESS CODES rene cence 10 Deleting an Access Code sees 12 Duress Code ss 12 ARMING THE SYSTEM s 13 Exit Delay 13 Regular System Arming sse 13 otay Armihig iie tet RM ARR RIRE 14 One Touch Arming VV 15 FasUEXIU oon 16 Keyswitch Push Button Arming eese 16 Manual Bypass Arming a 17 Bypass Recall een 18 Force Arming eint ees 18 Arming a Partitioned System sss 19 Esprit 642 LCD Keypad 1 No Movement Automatic Arming 21 Automatically Arm on Time cee eeseeeereeeeeeeeeeeneeeeees 21 DISARMING EEN 23 Disarming System A and B Separately 23 PANIC ZONES ee ees ion we eb nata EO dass asia 25 ADDITIONAL FEATURES eee 26 Ben Rn EE 26 Time and Date Settings 27 Keypad Mute e
11. NE Fire Trouble If the fire zone is cut the display will read TROUBLE 1 FIRE LOOP Esprit 642 LCD Keypad 31 9 0 FIRE ALARMS Upon a fire alarm the bell siren will operate in pulse mode 9 1 SILENCE RESET To silence reset a fire alarm enter a valid access code In case of fire follow your evacuation plan If there is no fire condition contact your monitoring company to avoid an unnecessary response 9 2 FIRE SAFETY IN THE HOME Reasonable fire safety can be achieved following a three point program 1 Minimizing fire hazards 2 Providing a fire warning system 3 Having and practicing an escape plan 9 2 1 Minimizing fire hazards The three primary fire hazards are 1 Smoking in bed 2 Leaving children home alone 3 Cleaning with flammable liquids such as gasoline 9 2 2 Providing a fire warning system Household fires are especially dangerous at night Fires produce smoke and harmful gases that can overcome sleeping occupants To warn against fire smoke detectors 32 User s Manual should be installed outside the proximity of each sleeping area or bedroom In addition a detector should be present on each additional story of the family living unit including basements 9 2 3 Having and practicing an escape plan Often there is little time between the detection of a fire and succumbing to its hazardous effects This may occur within two or three minutes upon detection of a fire Advance warning of
12. d ZONECS MEMORY INEN TO VIEN 6 User s Manual How Do I View the Memory Record 1 Press the mem key to view the list of zones that were breached during the last arming period The system will display the zone s that were activated 2 Use the A or V keys to scroll through the record 3 Press the cLEAR key to exit message and does not erase the memory contents Pressing the cLEAR key only erases the display Arm or disarm to erase the memory contents 1 7 EVENT LIST Your control panel creates a buffer which contains a record of all system activities including time and date This event list is saved even after total power loss How Do View the Event List 1 Press the mem key 2 Press the Nro key to view the event list The display will read EVENT TINE 3 Use the A or V keys to scroll through the event list 4 Press the cLEAR key to exit Esprit 642 LCD Keypad 7 1 8 INFO LIST Your Installer can program the control panel to include important information such as emergency numbers tips or notes This information is saved even after total power loss How do View the Info List 1 Press the INFo key 2 Use the A or V keys to scroll through the info list 3 Press the cLEAR key to exit 1 9 PARTITIONING With your instructions your installer can program your panel to recognize and control two separate areas System A and System B by ac
13. d on your system Esprit 642 LCD Keypad 11 3 0 ARMING THE SYSTEM You may arm the Esprit in five different ways in order to cover a wide variety of security situations We suggest that you familiarize yourself with all five arming procedures to take full advantage of your security system 3 1 EXIT DELAY After entering a valid arming sequence an exit delay timer will provide you with time to exit the protected area before the system arms The keypad may beep during the exit delay 3 2 REGULAR SYSTEM ARMING The keypad s green light must be on in order to regular arm the system This light will only illuminate if all zones are closed The LCD display will read SYSTEM REACY All doors and windows must be closed and there can be no movement in areas monitored by motion detectors If the green light is not on the LCD will display a sequential list of any zones that are open 12 User s Manual How Do I Regular Arm the System Once the light is on 1 Enter your access code The display will read SYSTEM IN EXIT during which the light will flash 2 After the exit delay the display will read FULL ARMED indicating that the system is armed 3 3 STAY ARMING Stay arming allows you to remain in the protected area while partially arming the system You may choose to have entry exit points such as doors windows and basement areas protected while other interior zones within the home are ignored
14. e functions How Do Enter Key Access Programming Mode 1 Press the ENTER key 2 Enter the MASTER CODE or USER CODE 1 3 Press the key that corresponds to the feature you wish to activate see Table 1 4 Press the ENTER or CLEAR key to exit Table 1 mem Panel Time and clear trouble 8 The display will read SETUP TIME TIME Enter two digits 00 to 23 for hours and two digits 00 to 59 for minutes TRBL Call PC via Telephone The display will read CALL TO PC This will initiate communication to the central monitoring station computer Your installer will indicate when this must be used 28 User s Manual FORCE Answer PC The display will read ANSWER PL This will initiate modem communication between your system and a central monitoring station Your installer will indicate when this must be used STAY Hang Up This will cancel modem communication between your system and the central monitoring station computer Your installer will indicate when this must be used Esprit 642 LCD Keypad 29 8 0 TROUBLE DISPLAY The screen can display several trouble conditions When trouble conditions occur the display reads SYSTEM TROUBLE If programmed by your installer the keypad sounder will beep Only the troubles that are relevant to you are listed below If a trouble appears and it is not listed below call your Security Company to come service
15. iit deed intern 27 Chime Zone Selection eee 28 KEY ACCESS PROGRAMMING 29 TROUBLE DISPLAY Neue oe crine ee 31 FIRE ALARMS ses ccncsonnnnneconoeccocauaenncese 33 Silence Reset 33 Fire Safety in the Home 33 Provision for the Disabled esses 34 TESTING YOUR SYSTEM ener 35 Fire Alarm Testing e EES 35 System Maintenance sssssssse 35 SYSTEM CHECK LIST eeeeeeceeeeenn nnn 36 Panic Buttons ccccccccccccesseeeseseeeeececeeceeeseeeaeeneeees 36 Zone Checklist near aiie 36 User Access Code List 38 2 User s Manual 1 0 INTRODUCTION Thank you for selecting the Esprit Security System from Paradox Security Systems The Esprit line of security systems bring together reliable yet simple products that offer state of the art security options Such options enable you to customize many of the advanced features through a simple keypad interface The Esprit system can report a wide range of status conditions to the central monitoring station Automatic test reports can also be sent to the central station to ensure that your system is functioning properly We recommend that such tests be conducted regularly Consult your alarm system installer for instructions All the actions performed in your security system will be
16. o exit access programming may be used to set panel time Panel time must also be programmed One Touch see Key access programming on page 28 6 3 KEYPAD MUTE The keypad can be programmed not to emit audible sounds including Chimed zones During Muting the keypad will only emit the Confirmation Beep Rejection Beep and beep when 26 User s Manual a button is pressed How Do Enable Disabled Keypad Muting Press and hold the cLear key A confirmation beep indicates that the keypad sounder has been turned off A rejection beep indicates that the keypad sounder has been turned on 6 4 CHIME ZONE SELECTION A Chime Zone advises you when it is opened by emitting a rapid intermittent beep tone How Do Chime a Zone 1 Press and hold the 9 key The display will read CHIME ZONE I ENTER NUMBER 2 Use the A V keys to scroll through the list of zones 3 Press the 2nD key to toggle the status of the selected zone chimed or unchimed 4 Return to step 2 to chime additional zone s 5 Press the ENTER key to save and exit or press the cLEAR key to exit without saving You may also toggle the status of a zone by entering e the 2 digit number of the selected zone Esprit 642 LCD Keypad 27 7 0 KEY ACCESS PROGRAMMING Several control panel features can be programmed quickly on the keypad The Security Company or installer may ask you to perform some of thes
17. s and hold the STAY key The display willread SYSTEM IN EXIT 2 The system will switch to exit delay mode LED flashes At the end of the exit delay period the system will return to Stay arming mode How Do Rearm in Regular Mode 1 With the system already Stay armed press and hold the ARM key The display will read 58 5T Ef IN EXIT 2 The system will switch to exit delay mode LED flashes At the end of the exit delay period the system will rearm in Regular arming mode 3 6 KEYSWITCH PUSH BUTTON ARMING Your system can include a keyswitch or push button which can be used to arm or disarm the system instead of using a Esprit 642 LCD Keypad 15 code If an alarm is generated in your system or in other rare instances you may have to disarm the system using the keypad Consult your installer for more information 3 7 MANUAL BYPASS ARMING This feature enables you to deactivate ignore specified zones the next time you arm the system Once armed and then disarmed the zones are no longer bypassed For example you may wish to bypass certain zones when workers are renovating part of your establishment The fire zone cannot be bypassed How Do I Manually Bypass a Zone 1 Press the BvP key The display will read ENTER CODE TO BYPASS ZONES 2 Enter your access code The display will read ENTER ZONE I TO BYPASS 3 Use the A or V keys to scroll through the zones 4 Press the BvP
18. te a medical alarm signal The display will read ALAR Press and hold both the keys 7 and 9 keys to generate a fire alarm signal The display will read ALAR 24 User s Manual 6 0 ADDITIONAL FEATURES Several keypad features can be programmed directly by you without the help of an installer 6 1 LCD SETTINGS You can modify the keypad settings to suit your needs How Do I Adjust the LCD Settings 1 Press and hold the 6 key 2 Choose an option 1 Backlight the keypad s light 7 is the brightest 2 Contrast character intensity 7 is the lightest 3 Scroll speed the scroll speed 1 is the fastest 3 Use the A V keys to modify 4 Press the ENTER key to save your choice and return to step 2 or press the cLEAR key to return to step 2 without saving your choice Esprit 642 LCD Keypad 25 6 2 TIME AND DATE SETTINGS How Do I Set a Time of Day 1 Press and hold the iro key The display will read PROGRAM KEYPAD SET TIME 2 Press the ENTER key The display will read SETUP TIRE TIME 3 Enter the time using the 24 hour clock i e 4 05pm 1 6 0 5 4 Press the V key The display will read PROGRAM KEYPAD SET DAS 5 Press the ENTER key The display will read SETUP DAY DRY FRI 6 Use the A Y keys to select the day 7 Press the ENTER key to save your entry The display willread PROGRAM KEYPAD SET TIME 8 Press the cLEAR key t
19. the backup battery be changed every three years 34 User s Manual 11 0 SYSTEM CHECK LIST 11 1 PANIC BUTTONS Keys Panic Alarm Type 1 and 3 Police or Silent Audible Not Used 4 and 5 Auxiliary or Silent Audible Not Used 7 and 9 Fire or Silent Audible Not Used 11 2 ZONE CHECKLIST Is this a partitioned system Yes No System A System B Zone and System Zone and System Description AB Description AB 01 04 02 05 03 06 Esprit 642 LCD Keypad 35 07 16 08 17 09 18 10 19 11 20 12 21 13 22 14 23 15 24 Entry Delay 1 is seconds Entry Delay 2 is seconds Exit Delay is seconds 36 User s Manual 11 3 USER ACCESS CODE LIST User Name System User Name System 01 16 02 17 03 18 04 19 05 20 06 21 07 22 08 23 09 24 10 25 11 26 12 27 13 28 14 29 15 30 Esprit 642 LCD Keypad 37 31 41 32 42 33 43 34 44 35 45 37 46 38 47 39 48 40 EN
20. the display will read B ARMED 3 11 NO MOVEMENT AUTOMATIC ARMING Your panel can be programmed by your installer to send a report and or arm the system if the system is not armed and there is no zone activity for a pre programmed amount of time For example you can use this feature when supervising the elderly individuals with chronic health problems or a person living alone 3 12 AUTOMATICALLY ARM ON TIME Your installer can program your panel so that you can setup a specific time during the day where the system will arm itself In this mode all protected zones and detection devices must be closed before arming can occur 20 User s Manual How do I Setup Arm on Time 1 Press the ENTER key 2 Enter the master code The display will read PROGRAMING MODE SECTION 3 Press the 9 key The display will read AUTO ARMING TIME TIME 4 Enter the time using the 24 hour clock i e 4 05pm 1 6 0 5 The display will read PROGRAMING MODE SECTION to confirm the entry 5 Press the cLEAR key to exit see Key access programming on page 28 and not The auto timer uses the control panel s clock setting the keypad s Esprit 642 LCD Keypad 21 4 0 DISARMING How Do Disarm the Security System 1 Enter through the designated entry exit door The keypad will beep and begin the entry delay timer 2 Enter your Access Code The light will go off and the keypad will s
21. tivating the system s partitioning feature Access codes can also be programmed to arm disarm one system or both systems simultaneously Use partitioning in installations where shared systems are more practical such as office warehouse buildings or apartment condominium complexes For more information see Arming a Partitioned System on page 18 8 User s Manual 2 0 ACCESS CODES Access codes are personal identification numbers that allow you to enter certain programming modes and arm or disarm the system In addition to the master code the Esprit control panel can be programmed to accept up to 48 user codes each with a unique access code Avoid programming simple or obvious access codes e such as your telephone number address or codes like 1234 Your installer will program the Esprit 642 to accept four or six digit access codes and will assign code definitions to all user codes The Master Code default 474747 and user codes are identified by a two digit code number where code numbers 01 48 represent access codes 1 48 and code number 00 represents the master code To create or modify access codes follow the steps indicated below Esprit 642 LCD Keypad 9 How Do I Create an Access Code The Master or User Code 01 must be used to enter programming mode in order to create access codes 1 Press the ENTER key The display will briefly read ENTER CODE TO PROGRAMMING MODE 2 Enter the Master
22. top beeping 4 1 DISARMING SYSTEM A AND B SEPARATELY If your Access Code has access to System A How Do Disarm System A 1 Enter through the designated entry exit door The keypad will beep and begin the entry delay timer 2 Press the stay key 3 Enter a valid access code The light will go off and the keypad will stop beeping 22 User s Manual If your Access Code has access to System B How Do Disarm System B 1 Enter through the designated entry exit door The keypad will beep and begin the entry delay timer 2 Press the FORCE key 3 Enter a valid access code The light will go off and the keypad will stop beeping Esprit 642 LCD Keypad 23 5 0 PANIC ZONES If you wish to signal a panic situation your installer can program three panic zones on your keypad You may request your installer to program panic zones that will generate alarms sirens or bells or silent alarms Both can generate and send reports directly to your central security station The panic zones can also communicate specific messages to your monitoring station For example press the panic sequence to call the police or the fire department Ask your installer for the exact definition of your system s panic alarms How Do I Use Panic Zones Press and hold both the 1 and 3 keys to generate a panic signal The display will read ALAR fi Press and hold both the 4 and 6 keys to genera
23. ws which zones are open but you can also press the A or W keys to view a specific zone Figure 1 2 Overview of Esprit 642 LCD Keypad MESPRITE The messages on the LCD screen display system n 2 Es Hs AD Se d status and guide you through operations OO ES e AC indicates power c option programmed by your CD installer C25 CeD Use these buttons to scroll D D through menus ES CD 5 A du dea fh Esprit 642 LCD Keypad 5 1 5 AUDITORY FEEDBACK Every time you press a key the system emits a beep This sound affirms that an entry has been entered When you enter information on the keypad it will guide you with these tones to communicate acceptance or rejection of your entries You should be familiar with the following keypad beep tones Confirmation Beep when an operation i e arming disarming is successfully entered on the keypad or when the system switches to a new status mode the keypad sounder produces an intermittent beep tone four short beeps Rejection Beep when the system reverts to its previous status or when an operation is incorrectly entered on the keypad the sounder emits a continuous beep tone beeep 1 6 ALARM MEMORY DISPLAY When the system is armed any security breaches are recorded and stored in memory This record contains all alarm situations that occurred within the last arming period Should there be an alarm recorded the display will rea
Download Pdf Manuals