Home
USER's GUIDE MANUAL
Contents
1. Image of Camera 1 by the Volume Key NOR Normal Image Factory Default MIR Mirror Image e CAMERA 2 Press the SCAN and or CA SEL Key select the Normal or Mirror Image of Camera 2 by the Volume Key Normal Image Factory Default e CAMERA 3 Press the SCAN and or CA SEL Key select the Normal or Mirror Image of Camera 3 by the Volume Key Normal Image Factory Default e Adjustable Guide Line Parking Guide Line Locate the cursor at DISTANCE by the SCAN and or CA SEL Key Select ON or OFF by the VOLUME Key ON Displayed the Adjustable Guide Line Factory Default OFF No displayed the Guide Line When the Camera 1 turns by the Trigger R gear the Standby Mode displays the Guide Line for the adjustment How to adjust the Parking Guide Line User can adjust the Guide Line in accordance with the Vehicle s Width as follows Guide Line Parking Line Is displayed when the trigger signal is engaged e Select the Left or Right Line by the SCAN CA SEL key e Adjust the Guide Line Parking Line to the left or the Right by the VOLUME key To adjust the parking guide line the DISTANCE should be ON in OSD Setting The adjustment is only applicable while the trigger is engaged 5 Camera SCAN MODUS ON OFF ON OFF ON OFF e SCAN MODUS Move to the option screen of the SCAN MODUS by pressing the MENU key Locate the cursor at a de
2. is On by pressing power button manually e Language 6 Language ENGLISH GERMAN FRENCH ITALIAN SPANISH DUTCH Locate the cursor at Language by SCAN and or CA SEL key Select the desired language by Volume key Factory default ENGLISH e RESET All set values are initialized to factory defaults Locate the cursor on the RESET by SCAN and or CA SEL key Select Volume key The monitor turns off 2 Picture PICTURE CONTRAST 50 0 100 BRIGHT 50 0 100 COLOR 50 0 100 TINT 50 0 100 CONTRAST Adjust the Contrast by the Volume Key Factory Default 50 e BRIGHTNESS Press the SCAN and or the CA SEL Key adjust the Brightness by the Volume Keys Factory Default 50 e COLOR Press the SCAN and or CA SEL Key adjust the Color the Volume Key Factory Default 50 e TINT Press the SCAN and or CA SEL Key adjust the Brightness by the Volume Key Factory Default 50 3 Camera CAMERA SCAN TIME O SCAN TIME 0 SCAN TIME 0 1 TRIG DELAY 0 2 TRIG DELAY 0 TRIG DELAY 0 9 9 9 9 9 9 e CA1 SCAN Move to the camera 1 by the SCAN and or CA SEL Key Adjust the displaying time of the camera 1 while scanning camera and it is set up from 0 to 9 seconds by Volume Key Factory Default 3 second e CA2 SCAN Move to the camera 2 by the SCAN and or CA SEL Key Adjust the displaying time of the camera 2 while scanning camera and it is set up fro
3. USER s GUIDE MANUAL 5 Digital TFT LCD Monitor Model MTB5300D I Contents Warning L Contents Warning Front Feature Accessory Operation IV Wiring Connection V Technical Specification WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN To reduce the risk of electric shock do not remove the cover or back No user serviceable part inside Refer servicing to qualified service personnel The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure that may of sufficient magnitude to constitute a risk of electric shock to persons This exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance Design and Specification are subject to change without notice II Front Feature amp Accessory Front Feature SCAN UP 2 SEL DOWN MENU 4 Dimmer VOLUME DOWN VOLUME UP POWER Accessor Camera Input Cable Fan Type Stand User s Guide G e 9 O Operation 1 Menu Control Key 1 Power Key Power LED indicates the RED Color at the Power OFF Stand By Mode Power LED indicates the GREEN Color at th
4. e Power ON LAST MEMORIZED CHANNEL displays when the POWER turns ON Factory Default 2 Menu Key e When pressing the MENU Key during POWER ON Mode the OSD appears and the selected letters on OSD are classified in a different color e When pressing the MENU Key repeatedly in OSD Mode the monitor displays in order as FUNCTION gt gt of OSD 3 Dimmer Key Monitor Brightness is manually adjustable by pressing DIM button depending on the surrounding condition 4 A SCAN Key e When pressing A SCAN Key on displaying image displays Camera 1 image gt Camera 2 image gt Camera image 3 repeatedly until pressing A SCAN Key again e When pressing A SCAN Key on the MENU the cursor moves up for selecting an option 5 SELV Key e When pressing CA SEL key repeatedly on displaying image the display is changed CA1 gt CA2 gt CA3 in order e When pressing SEL v Key on the MENU the cursor moves down for selecting an option 6 Volume Up Down Key increase the Volume press Volume Key VOLUME e To decrease the Volume press Volume Key 50 e Adjustable Volume Range 0 100 Factory Default 50 2 How to set up the MENU Function 1 Function FUNCTION AUTO POWER ON OFF LANGUAGE ENGLISH RESET gt e POWER ON OFF ON When ACC is On the display is On automatically OFF The display
5. m 0 to 9 seconds by Volume Key Factory Default 3 seconds e CA3 SCAN Move to the camera 3 by the SCAN and or CA SEL Key Adjust the displaying time of the camera 3 while scanning camera and it is set up from 0 to 9 seconds by Volume Key Factory Default 3 seconds If the value is set at O the image of the camera is not displayed while scanning the channels Skipping the channel e CA1 TRIGGER Press the SCAN and or CA SEL Key adjust the displaying time of the camera 1 after the trigger is disengaged and it is set up from 0 to 9 seconds by Volume Key Factory Default seconds e CA2 TRIGGER Press the SCAN and or CA SEL Key adjust the displaying time of the camera 2 after the trigger is disengaged it is set up from 0 to 9 seconds from 0 to 9 seconds by Volume Keys Factory Default 3 seconds e TRIGGER Press the SCAN and or CA SEL Key adjust the displaying time of the camera 3 after the trigger is disengaged and it is set up from 0 to 9 seconds from 0 to 9 seconds by Volume Keys Factory Default 3 seconds If the value is set at 0 the display is promptly changed to the image of the camera displaying prior to the trigger on after the trigger is disengaged 4 Camera CAMERA MODE CAM 1 NORMAL MIRROR 2 NORMAL MIRROR CAMS NORMAL MIRROR CAM1 DIST MARKER ON OFF e CAMERA 1 Press the SCAN and or CA SEL Key select the Normal or Mirror
6. sired camera by the SCAN and or CA SEL Key Select ON or OFF by the Volume Key The camera set at ON is not scanned when a user tries to scan all cameras one by one by pressing CA SEL V key It is useful to select OFF for those camera channels which are not connected with a camera Wiring Diagram MONITOR CONNECTION DESCRIPTION 1 E 5 Fa DOTA POWER Shutter Memory DC12V VIDEO IN GROUND AUDIO IN ACC 10 307 Ground Wht Green Thayer Trigger 12 31 CA amp 5 NG 2 re SN 1 fe 5 a MONITOR CONNECTION DESCRIPTION i gt ING 3 VIDEO IN 4 GROUND 5 AUDIOIN Technical Specification via Reversing gear signal or Auto power Dimensions 105 W x 152 H X 23 D mm Stand Bracket Camera Input Cable Manual Dimensions