User Manual Envi logger C1 & CS1 Version: R1A Date: 2010-09-09

image

Contents

1. ange User Settings Download data Start a new Select from sounding parameters to probe Used show during when first Backup your Change sounding Fetch sounding attempt dab settings for data for fails for some Bua graph drawing executed reason Please note that the leftmost button has a blue frame This is since this button currently has focus and will be pushed if you have a keyboard and press Return or Space depending on your computer oS When you press this key focus will move from one button to another in a predefined manner After pushing it enough times you will have passed all focusable objects and you are back to having focus on the NEW button There are also keyboard commands for pressing almost all buttons One letter in the name of each button is underlined The underlined character is the keyboard command key for pressing it To use the keyboard command you press ALT lt the underlined character gt So to press the NEW button using keyboard commands you press ALT N This is a complete list of available keyboard commands in main window NEW ALT N START ALT S PAUSE ALT P STOP ALT T SETTINGS ALT I VIEW ALT V SCROLL ALR C NOTE ALT O DATA ALT D FILE ALT F ERASE ALT R BACKUP ALT B Some button are gray showing that they are disabled What buttons are disabled and enabled varies depending on what state the application is in Initially the buttons for START STOP PAUSE and FILE are
2. REDUMP gt When data is downloaded the wait dialog disappears Sometimes the system warns that data for some depths is missing This is generally not an issue since the system is a bit oversensitive to this but you should be alert and study the graphs thoroughly If there are parts of the graphs where data is 100 stable not changing at all you might have suffered from power failure in the Memocone This in turn is generally caused by batteries with too little power left or by dirty connection areas in the Memocone The Memocone uses the probe itself as ground in the electrical circuit So it is vital that battery threads and connection area between Memocone and battery tube are clean Moreover it is important that the brass screw on the battery plug is also clean Open and browse stored soundings You press DATA button in the main window to open the dialog for selecting a sounding for which you want to browse data The dialog now shown gives you the option to pick one of the latest 20 executed sounding see blue ellipse below or you can search filter out the sounding you want to view by filtering from date and project ID see red ellipse and pressing respective button to the right The soundings corresponding to your selection criteria will be available in the RETRIEVED PROBINGS drop down menu GET PROBINGS amp PROJECT l Month Day Year Month Day SELECT PROJECT PROJECT
3. jlig Here you must enable loading backup before actually doing it Thisisa precaution to avoid accidental b a L If you press File amp Email the you will have a dialog for specifying settings for this his checkbox is enabled if you select the other checkbox If you select also this checkbox you must define Email settings below Email settings can be found in your mail client under Account settings Your Email address specify your own Email address Your SMTP server Here you must specify the smtp server you use to send Emails Typically such a server is called something like smtp lt Mail Provider gt com or smtp lt Your Domain gt com You find it in you account settings Port This is typically 25 or 2525 or something You find it in you account settings Email addresses to send to Here you specify Email addresses for all receivers of files Email addresses are specified one address per line After you are finished you press SAVE for the system to remember your settings You then press SAVE also the the USER SETTINGS dialog that you are returned to Troubleshooting To send log files to Envi press SYSTEM This button currently only has one function and that is to send the log file but will be supplemented with other features later For sending log files you must have entered the correct data for your Email Account in the dialogue for sending sounding data files see chapter User Settings abo
4. GET SOUNDINGS A RETREIVED PROBIQSS TATEST 20 PROBINGS Not selected A When you have found the sounding you want to browse in either retrieved probings OR in latest 20 you select the sounding you want to browse and press OPEN SELECTED PROBING The data for that sounding is then fetched from database and will be presented as graphs in the main window The final depth for the sounding you have fetched is presented in the Depth text box see blue ellipse below The name of the sounding project id sounding id and method are all presented in the text boxes marked by the red ellipse below The graphs you have defined for the method will now be presented in the main window You may now select to create a file or erase the sounding by pressing either FILE or ERASE button You may of course also start a new sounding by pressing NEW or fetch data for another sounding by again pressing DATA E A Envi G1 CPT monitor Version 1 84 Create file If you select FILE you will first be requested to specify the parameters you want to print in your file These parameters are not the same as the parameters for viewing and will be remembered separately by the system So the next time you want to create a file the system will suggest to output the same parameters as was last used When you have selected the parameters you want to include in the file you are requested to select the type of file you want to create T
5. User Manual Envi logger C1 amp CS1 Version RIA Date 2010 09 09 Introduction Envi logger G1 is a PC based logger system where all data is saved in a database installed on the PC Data from depth rotation sensor and inductive transducer if you run a CS1 is stored in as raw values as measured by the transducer but it is sampled digitalized Data is stored continuously after START has been pressed until STOP is pressed This results in a very robust data collection mechanism where data can be retrieved for a sounding at any time after the sounding has been executed Digital data from depth transducer and inductive transducer is transferred on a CAN bus to the logger This makes data transfer very secure and insensitive to noise A lot better than in a traditional analogue system You can specify what parameters to during the sounding and also what parameters to include in the files you create Parameters you view can differ from what you include in the file File formats allowed this far is SGF STD format or a simple tab separated format More formats will be added later and will be available for all having the logger system Settings made by the user are remembered by the system and used next time the system 1s used The system consists of two program modules EnviPackage The foundation software handling transducer data collection and database interaction CptApplication The application to start if you want to work with CPT or SPT St
6. When done you can close the menu by pressing Close Menu tab Now database and drivers have been installed and the application shall be installed This is done by running double click the Setup CptLogger lt Version number gt lt Language gt msi iS DJ Setup Cptlo gger L97 U5 msi Please note that you will probably be prompted if network access shall be granted one or several times during installation It is then essential that you grant network access Otherwise the system will not run Starting the system Ge enviPackage CptAprlicat After installation icons are placed on your desktop The application is started by double clicking the CPTapplication icon When you start the application 2 the enviPackage 1 will be started prior to starting the application If automatic start of enviPackage fails it will be due to too slow start up of the enviPackage may happen when you download and install Windows updates etc you must close the application and restart it 2 When you start the system all processes are started and the application and database are synchronized etc This may take some time and you will have a wait dialog that will be showing until this has been accomplished As soon as the synchronization is finished the wait dialog is closed and the main window opens Any problem failure will be reported through pop up windows The main window looks like below ia i j Envi G1 CPT monitor Version 1 84
7. art the application you want to run EnviPackage will then automatically will be started prior to application start by the application If your PC is under heavy load can happen when you download and install Windows updates etc it may be that EnviPackage is not started quick enough and the application will warn for no EnviPackage started You must then restart the application Installing the software CAN driver installation COM port driver installation Browse the CD Explorer Close Menu You will have received the installer for the database and drivers either on a USB memory stick or CD or as a downloaded zipped folder To install this software run the AUTORUN EXE file You will then get this pop up window Follow these steps to install this software 1 Install the database by pressing first tab MySQL database installation 2 Install java runtime environment JRE if not already installed on the PC Nothing bad happens if you try to install this despite it is already installed Press second tab java JRE installation to install JRE 3 Install the CAN driver software by pressing tab marked CAN driver installation 4 Install COM port driver by pressing tab COM port driver installation This driver installation sometimes behaves a bit strange it is commercial software so not much we can do about it and no DOS window is popped up To ensure installation if no DOS window pops up please press the tab again 5
8. ax 500 kPa iene U2 Max il kPa SPT Fal 65H Blows 20 cm No of meters 11 4 m Classification method En None Robertson 86 Eslami Fellenius Resistivity 1 000 om APPEARANCE ee oe Remember Close LI Leave open Line width graph 2H Pixels Delay for dissipation test 5 s Line width coordinate axis 2H Pixels UNITS Size of Note Rectangle sH Pixels Diameter dissipation circle 7H Pixels a Note text Code Code Text Invisible L cm min Here you can define settings for collection of dis To save your settings and close the GRAPH SETTINGS dialog you press SAVE Alt S To abort and not save anything press ABORT ALT A Some settings will change immediately and show in the graph drawing but they will not be stored and remembered until you press SAVE Ending a sounding You press STOP in the main window to end the sounding If you use a wireless Memocone you will have a pop up where you will be requested to reconnect the probe and press OK when done So now you retract the probe and when you have it up on surface again you connect it to the logger When that is done you press the OK button in the pop up window Data is now downloaded from Memocone to logger and you will see a wait dialog as per below ILD Envi G1 CPT monitor Version ked STOP PAUSE SCROLL NOTE Projekt T SYSTEM ee 43 Anvandarmanua ge Envi G1 CPT mo lt SG MG O 15 02 SE
9. gray disabled since there is no active sounding You have two main options for continuing at this stage 1 Start a new sounding to record data for 2 Get sounding data from database In addition to the two main choices you may also alter settings for GRAPHS or for USER You can define many different settings to make the system personalized for your needs More detailed descriptions of settings are found in later chapters The NOTE button is not gray disabled initially but has no use at this stage The same goes for the SCROLL button Initialize a new sounding If you press NEW a dialog window as per below appears You must enter both a project ID a Sounding ID and a method in order to be able to proceed The system will then detect if the three parameters as a combination are unique If not you will be requested to change name Method to use Only CPT Set indentifier data All other fields are optional to use As of now you must manually enter GPS coordinates if you want to include those Fields are automatically populated with the same data as was used for latest sounding next time you press NEW After having changed the fields you need to change you press SAVE Alt S and you will be back in the main window and the system is ready for start a new sounding If you choose method CPT the system will verify that a Memocone CPT probe is connected to the logger If not you wil
10. hs You press the NOTE button see blue ellipse above A dialog window will then appear allowing you to add notes according to your choice l o 9 982 CERES In the drop down menu Code all SGF note codes and notes are available The Depth text box will hold the value of the depth that was when you pressed the NOTE button You can change the depth if you want to You can also change the depth graphically in the plotted graphs later on if desired You can create your own codes by using the numbers not yet occupied by the SGF codes All free codes can be found in the New Code panel These personal codes will be remembered by the system You can also add free text notes Simply write whatever you like in the NOTE text box and it will be added to the sounding with note code 0 When you have entered the note you want to add you press SAVE Alt S to save it and close the NOTE dialog You can abort by pressing ABORT and no note will be added and the dialog closed Graph presentation settings To change settings for graph drawing like scaling of coordinate axises you press the SETTINGS button in the GRAPHS panel in the main window B a Here you can change max value coordinat Set presentation parameters for grapl RESOLUTION AND MAX VALU tempe Remember Inclination 5SH Degrees ROP Max 500 mm sec Force 200 kN 50 Qc Max MPa i Friction Ratio 454 Fs M
11. l be requested to connect one When a Memocone is connected the C1 CS1 logger system and the Memocone will synchronize This may take a while and a wait dialog will appear NB The first time you use method you will will be requested to define what parameters to view graphs for during the sounding after you have pressed the SAVE button The SENSORS dialog see page below will pop up and ask you to define parameters to view ABORT will take you back to the main window in the state you left it Starting and execute a sounding The System opens graph windows for the parameters specified for the method you use ra Envi G1 CPT monitor Version CONTROL GRAPHS o x Si SAVED PROBINGS USER 7 NEW START SETTINGS D ATA FILE ERASE SETTINGS STOR PAUSE SCROLL Tere ID Projekti 0 CPT SYSTEM wack z m BACKUP ce Qc Fs u2 Incl Temp FR Resist blows RESTORE If you want to change what parameters to view you press VIEW button see red ellipse in the picture above and the below SENSOR pop up window will appear and you can mark the check boxes for the parameters you want to view Only parameters for which you have a sensor will be selectable Please note that the parameters you want to view is not the same as what parameters you
12. ve Send log file with senvice envise Backup and Restore You can always back up the data you have in the database This is done by pressing the Backup button in the main window the button circled in red below S Envi G1 CPT monitor Version 1 84 cn el bs eS CONTROL GRAPHS SAVED PROBINGS USER start _sertines view pata me erase _ L SEttines _ stop pause ID Projekt1 0 CPT Depth ROP Force Qc Fs u2 Incl Temp FR Resist blows _ PROBE DATA 9971 85 08 0 0 00 0 0 0 0 0 0 0 REDUMP ROP mm s 69 95 222222225 U2 kPa 0 0 FJ Qc MPa 0 0 o 20 60 100 140 180 BACKUP FROM TO Year Month Day Year Month Day You specify the dates between which you want to store backup data and press RUN If you change your mind and do not want to backup you cancel by pressing on the cross and close the window To restore the database from a previous backup or load the backup on another computer you must first enable the restore of the database open the user settings and set the Backup possible see previous chapter The backup file shall be placed in folder C EnviLoggerGI1 prior to starting the database restore The name of the backup file shall be ENVILOGGERGIBACKUP ZIP
13. want to output in a file That is defined separately OP Temperature Feed Force Seismic Qc _ Resistivity CFs LI Soil Type Qu SPT Friction Ratio Inclination In order to start a sounding you press START You will then have a pop up see below where you can set start depth for the sounding you will execute here or you ran anter tha You can change start level by rolling the wheels BACKUP RESTORE SYSTEM reading will be done ned zero PPROBE DATA eter Cent RT E gt u ar mM p j 9 sift T SAVED PROBINGS ID Projekti er ABO TALL SENSORS MUST BE UNLOADED DURING ZERO READING Zero reading takes less than a second and then execution continues Decimet Immediately after start level has been defi Depth cm The system now starts to read and store sensor data As soon as you have a change in depth graphs will start to be plotted Measure values can also be seen in the different squares above and in graph window headers Fa You save the start depth by pressing SAVE keyboard command ALT S If you press ABORT no sounding will be started and you will return to the main window in the state you left it BA Envi G1 CPT monitor Version 1 84 CONTROL Notes During the sounding you can add notes in your grap
14. you can simply navigate to the folder where you want to place the file and press Save button If you want to change the file name you can simply write whatever name you like in the File name text box User settings There are settings also for personalizing certain behavior for creating files and if you want to have a separate file with notes etc To access these settings press SETTINGS in USER panel see red arrow eJimici cer monitor Version 1 84 rE es NEW START SETTINGS VIEW DATA FILE ERASE SETTINGS STOP PAUSE SCROLL NOTE Projekt1 0 CPT SJD EM BACKUP RESTE 9971 5508 0 0 00 0 0 0 0 0 0 0 EJ ROP mmis 69 95 22222222 E U2 kPa 0 0 22222222225 LEJ ac MPa 0 0 2222222222 EE Fs kPa 0 0 22222222225 LEJ inclination Ngo 0 0 22222 Resistivity Om 0 0 22222 1 Here you can define if a separate file with all notes made during the sounding shall be written to a separate FILE SETTINGS file with all notes CREATE FILE DEFAULT TYPE FILE SEPARATOR NOTE FILE USER SETTINGS One file per borehole SGF L comma YES NO L One file per project _ TAB voveysemicolon Press this button to open the Fil amp Epost ICATION ROD CHANGE _ Auto detection Manual Max width graph window FULL SCREEN Depth multiplier YES NO Start button passive time Autodetect level REMOVE COM Some settings are disabled and can not be changed by the user Ladda Backup M jlig Ej M
15. ypically a TXT Tab separated file is used in non Nordic countries and SGF is used in Nordic countries SES The system suggest a file name according to project ID sounding ID method with the extension std for SGF type files and txt for TXT type files When you have specified file type to create you can also specify where to place the file in a typical save file window as per below my desktop is in Swedish as you can see but the principle is pretty evident anyway Lg Spare fi Sparai ME Skrivbord 8 em Namn Storlek Typ Senast andrad SGF m te 20091216 aS S lj proj2 Filmapp E Filmapp Filmapp m 2 CptApplication enviPackage sCPTu 8 Genv c aks Genv g Filmapp FJ ae e 639 byte MWDapplication 4 Palm Desktop rt inOCPT Genvag hil J Genv g lt i Genvag 7 1 51 kB Sieve 1 57 kE 1 94 kB Mozilla Firefox SE CDBurnerXP JE Connect Genv g R E Genv g lt ae Genv g 1 68 kE eA 1 67 kE L VE 1 71 kB SolidWorks eDrawings 2010 SILKYPIX Developer Studio VLE media player a Genv g 30E MA Genv g Dator 1 98 kB Genv g 863 byte PC Mon GIMP 2 OpenOffice org 3 1 Genv g Genvag Genvag 782 byte 902 byte 999 byte Natverk DD Skype avast Antivirus ean NetBeans IDE 6 7 1 S Genv g l Genv g Genv g P 1 53 kB a 1 80 kB po 1 81 kB InterVideo WinDVD amp 6 Ena g A Naty e rk 1 76 kB c ly Delat 241 412 10104 8 std If you accept the file name given by the system