Home

User Manual

image

Contents

1. 2011 0058 issue 3 Fr i Operator chair Carl Mk2 Table of content 1 2 2 1 2 2 2 3 3 4 4 1 4 2 4 3 4 4 4 5 4 6 O 2 0 vi Operator chair Carl MK2 sina nel a lea o aa ase d na ea la eki 3 Important Before USC sssssssssssssssssrsssrrn rnnrrnn obna nei RR ARR ARENA KRA RR 3 UPPG CK NIO ROP R O O ae ni 3 Installation na 4 SAO AEO SE a ea Ne one 6 Product identification label ccccsssccssseceeseeeeseseeseeeesesaseneaneees 7 Basic adjustments of the chair nana 8 Chassis wheels and electrical brake 8 Chair height adjustment 000000000 een nen nn 8 Seat angle adjustment 220 a 9 Backrest angle and height adjustment 9 Rilis safety armrest Model R6 een 10 One hand grip armrest Model R72 11 Battery charging and emergency Stop sr srrsssrr 12 Cleaning and Maintenance eeeeoeeeeeoee nesen 13 o z o o P RR M a A A Aa A EEA E ARE A 15 Technical SpecifiCatiON sssssssssssssssssssarssnrsnrsnannn rn nana nanannananananaa 15 Disposal and recycling nnnnnnnnannnananannnna nana nanannnna nana 16 MV OTTO LV a A E E Melo M le ea 16 Page 2 of 17 BA ini 1 Operator chair Carl Mk2 Thank you for choosing the Rini Operator chair Carl Mk2 Operatorsstol Carl Mk2 Carl Mk2 i
2. eguipped with large high guality ball bearing wheels which facilitates movement The rear wheels are lockable by an electric brake which is controlled by a button alternating with on and off on the right side When the brake is used a tone sounds Always activate the brake during surgery to prevent accidental movement of the chair 4 2 Chair height adjustment The seat is raised and lowered electrically where the lifting construction consists of a battery powered motor control box and a Sid 8 av 17 battery pack Seat height is controlled by two buttons on the sides of the front wheel this by pressing with the heel on the buttons The chair may not be used by persons weighing over 120kg 4 3 Seat angle adjustment The chair is eguipped with a lever on the right hand side to adjust the seat angle between 15 and 45 Adjust the seat to a comfortable position by lifting the lever which then locks in this position when it is dropped 4 4 Backrest angle and height adjustment The chair is eguipped with a lever on the left side to adjust the backrest angle between 15 and 20 Adjust the backrest to a comfortable position by lifting the lever which then locks in this position when it is dropped Sid 9 av 17 ha rini Operatorsstol Carl Mk2 The backrest height adjustment device is placed on the back of the chair Adjust the height by loosening the knob and lock a suitable position by tightening it agai
3. lacquered surfaces Electronic parts Water Use damp cloth hand control control box and battery Battery charger Water Use damp cloth Periodic maintenance Monthly Hinges and joints Use non corrosive standard instrument spray Armrest locking Use non corrosive standard lubrication spray system Accessories Please contact your local distributor or Rini for information about accessories available for your eguipment Spare parts Please contact your local distributor or Rini for information on spare parts available for your eguipment Repairs The eguipment should only be repaired by Rini or a Rini authorised service centre Eguipment to be repaired under warranty must be sent to Rini factory or an authorised Rini service centre Sid 14 av 17 Warning Any unauthorised repairs or modifications to the eguipment may result in eguipment malfunction Furthermore this will render the warranty null and void 7 Safety The Operator chair must only be used in accordance with its intended purpose as described in this manual Incorrect use or deviation from the safety instructions could lead to damage of the eguipment and or personal injury This manual should always be available near the Operator chair Please observe the warning labels on the eguipment Warning and other labels The warning sign is used when there is a risk of severe danger to the patient personnel or the system Statement of CE conformity The O
4. 120 00133 00 Serial number 0001 00 External charger TP8 Protective Class IP24 SWL 1500N Mode of operation 10 Max 2min 18min Standard EN 60601 2 Made in Sweden saj Issue 1 2006 0072 Label description Warning risk exists Read the information text in the user manual T Type B eguipment with a defined degree of protection against electrical shock SWL Safe Work Load The eguipment should not be exposed to greater force corresponding to x 0 1kg per N than listed Average relative operation rest during a work Mode of cycle Where 10 corresponds to 6 minutes operation operation per hour or 2 minutes continuous operation under full workload The eguipment is manufactured in accordance Standard with specified medical standard EN60601 2 46 Sid 7 av 17 Operatorsstol Carl Mk2 roll I 4 Basic adjustments of the chair Carl Mk2 has simple intuitive controls and buttons to adjust the chair to an effective and ergonomic working environment for the operator For greater clarity these are indicated in yellow Safety armrest Rilis Back height adjustment Seat angel adjustment Back angel adjustment Chair height adjustment Electrical brake for rear wheels 4 1 Chassis wheels and electrical brake The chassis design with 3 wheels combine high availability of technical eguipment on the floor with high stability The chair can also be eguipped with pedal trays as accessories The chair is
5. Setting 4 By pulling the lever upwards the armrest can be adjusted to an optimal working position Set the armrest in the desired position and release the lever to lock the position A The armrest should not be loaded with more than 10 kg 5 Battery charging and emergency stop The Carl Mk2 chair is battery powered and has its own custom battery charger that handles 100 240V AC power The charging socket is located on the back with an LED to indicate charging status A fully charged battery is sufficient for about five days during normal operating conditions but daily charging is recommended because full discharging of the battery reduces battery lifespan For optimal performance the battery should be recharged frequently preferably every night and at least every three months to avoid damage caused by self discharge A new or completely discharged battery must be charged for 24 hours When the battery is fully charged the charger switches automatically to maintenance charging to avoid overcharge Sid 12 av 17 Operatorsstol Carl Mk2 Charge intake and LED indicator Emergency stop The emergency stop must not be activated during charging A Important that only the dedicated charger for the chair is used A 6 LED indicator shows the following status Battery status Green LED indicator Battery charging Lit constantly Battery OK Unlit During operation Baitery lt 20 blinking twice sec a
6. gery where the operator needs a stable seated work position with flexible relief for the arms The design of Carl Mk2 chair gives great freedom of movement to the surgeon while the chair provides space for other equipment at the feet Intended uses include e Neurosurgery e Eye Surgery e Ear nose and throat surgery e Facial Plastic Surgery e Robotic Surgery e Dental Surgery The chair is intended for indoor use and use on floors with normal floor standard The chair may not be equipped with other accessories or components than those authorized by Rini Ergoteknik AB Repairs and other technical measures should only be performed by personnel authorized by Rini Ergoteknik AB The chair may only be used for the purposes specified in this manual Any other use may pose a risk to the user The chair should not be used for operators that weigh more than 120kg The wheels must be locked with the electric brake during surgery When transporting the chair it should be empty and in its lowest position The chair is not designed for person transports Sid 6 av 17 3 Product identification label The label is located on the back of the chair and shows the product part number and its unigue serial number For guestions about this product always specify these numbers to facilitate identification CINI a Rini Ergoteknik AB Fagelsangsvagen 3B sti SE 186 42 Vallentuna Phone 46 8 594 771 70 Fax 468929279 Product Code
7. ith upper and lower stop screws Mount armrests In the back or front position Sid 4 av 17 Adjust the armrests to a suitable width by pushing them into the brackets and thereafter tighten Please note that there is a back and front position where the armrests can be mounted JA Upper stop screw Ta Lower stop screw Install the backrest by first removing the upper stop screw This allows the backrest to move sufficiently deep so the lower stop screw can be threaded out The lower stop screw is then threaded out so far that the backrest can t be taken out completely but at the same time without scratching when the backrest is adjusted in height The upper stop screw is then reassembled and covered with plastic cover For safety reasons including both person and product it is necessary to read this manual or having received sufficient training in using this product Before using the product please check the following e That the product has not been damaged in transport e That adjustment of back seat height and armrest can be done according to this manual e That the electrical brake is working e That the battery is fully charged Please contact your local Rini representative if you have any questions or concerns Sid 5 av 17 Operatorsstol Carl Mk2 2 3 gt gt gt gt gt gt CINI Intended areas of use The operator chair Carl Mk2 with three wheels is developed for different types of microsur
8. late is curved and underneath eguipped with a rail Loosen the black locking wheel to position the armrest Tighten when the correct position is found The armrest can also rotate around the black locking wheel allowing maximum flexibility and ergonomic relief It also helps the operator to be seated or get up from the chair and still be able to maintain sterile hands by using the elbows to rotate the armrests A The Rilis armrest should not be loaded with more than 20 kg 4 6 One hand grip armrest Model R7 The R7 model is suitable when a limited adjustment range is needed and it is desired to be able to adjust the armrest with only one hand 4 Lever for fine adjustment of the armrest position 3 Coarse adjustment of the width of the armrest 2 Coarse adjustment of the position front rear mount 1 Coarse adjustment of armrest height Sid 11 av 17 Ad rini Operatorsstol Carl Mk2 Setting 1 coarse setting There are two brackets on each side of the chair under the seat Normally the armrests are placed back of the chair but could be in any location on the right and left sides Setting 2 coarse setting The width between the armrests can be adjusted by loosening the locking handle under the seat Setting 3 coarse setting The height of the entire armrest can be adjusted so it is in the center of the work area for subseguent fine tuning Use the locking handle to set the appropriate armrest height
9. lation 10 Warranty In accordance with Rini s general terms and conditions the warranty on the eguipment is one year from date of purchase Sid 16 av 17 Rini Ergoteknik AB Fagelsangsvagen 3B SE 186 42 Vallentuna Sweden Phone 46 8 594 77170 Fax 46 8 929 279 Email infoQrini se www rini se
10. n 4 5 Rilis safety armrest Model R6 Rinis patented satety armrest Rilis has five different settings to offer an optimal ergonomic working position 5 Lock wheel for adjusting the armrest longitudinal and lateral o 4 Buttons for fine adjustment of height and L a position 3 Coarse adjustment of the width of the armrest 2 Coarse adjustment of the position front rear mount 1 Coarse adjustment of J armrest height Setting 1 coarse setting There are two brackets on each side of the chair under the seat Normally the armrests are placed back of the chair but could be in any location on the right and left sides Sid 10 av 17 Setting 2 coarse setting The width between the armrests can be adjusted by loosening the locking handle under the seat Setting 3 coarse setting The height of the entire armrest can be adjusted so it is in the center of the work area for subseguent fine tuning Use the locking handle to set the appropriate armrest height Setting 4 By pressing the buttons the armrest can be adjusted for an optimal working position To release the armrest you need to use two hands for safety reasons One hand to move the armrest pad up and down while the other hand push the button Set the armrest in the desired position and release the button to lock the position Note that the adjustment of the armrest should be without load Setting 5 The armrest p
11. nd buzzer sound If the overload breaker has tripped activate the emergency stop and wait at least 10 minutes and make sure the charging cable is not connected After that period of time the overload breaker should have been reset Then release the emergency stop If the chair is still not working the battery is probably empty Connect the charger and charge the chair at least 24 hours Batteries have a limited lifespan and battery module must during normal working conditions be replaced after about four years A new battery module can be ordered from your local distributor or Rini Used batteries are recycled in accordance with the instructions provided for the lead acid batteries Cleaning and Maintenance No part of the equipment is normally in contact with the patient and the armrests are draped during surgery Sid 13 av 17 Ad rini Operatorsstol Carl Mk2 Recommended disinfectants Part Product Other information Seating and other Virkon 1 concentration parts of art leather including most Disinfectants containing alcohol cannot be used due possible to dehydration of the leather or nylon disinfectants without alcohol Foot control and Noedischer 1 3 concentration other electronic Dekonta 0 5 concentration parts CCOTRADE RW Including most disinfectants Recommended cleaning agents Part Product Other information Padding wheels Water and soap Use damp cloth and frame Parts of metal and
12. perator chair 120 00133 00 conforms to CE according to MDD 93 42 EEG Approved according to standard EN 60601 2 46 and EN 60601 1 8 Technical specitication General Cushions Medical classified material black colour standard or other colours as options Operator data Lifting capacity 120 kg 264 lbs max weight operator Height adjustment 490 800 mm foot control by buttons on the side Back support Standard H 250 mm x B 280 mm other types Sid 15 av 17 Operatorsstol Carl Mk2 as options rir Inclination Angle 15 till 20 Height 200 mm till 300 mm from seat Type Standard L 420 mm x B 460 mm other types as options Inclination Angle 5 till 15 Armrest Type Rilis safety armrest Shape Boomerang standard other types as options Adjustment Height angle and length Brake Type Electric with on button control for back wheels Temperature Relative humidity Atmospheric pressure 9 Disposal and recycling Rini Operator chairs are manufactured using environmentally friendly materials mainly stainless steel aluminum PVC and plastics Rini recommends that the eguipment is demounted as far as possible for recycling purposes Battery X Used batteries are recycled in accordance with the instructions provided for the lead acid batteries Electronic parts and cables X Electronic parts and cables are to be disposed of as electronic waste in accordance with local legis
13. s the second generation of Rini s popular electrically adjustable operator chairs where lots of user feedback and new technologies have been combined The goal has been to provide a quality chair with a small foot print maximizing the area around the feet often where pedals and other equipment are placed At the same time for the surgeon Carl Mk2 offers maximum ergonomic comfort by extensive configuration options achieved by the use of intuitive hand grips The Carl Mk2 R6 is supplied with Rini s patented armrest Rilis that can be adjusted with high precision to the desired position For safety reasons adjustments require two handed movement to adjust height and angle The armrest board is able to pivot and slide as required The chair is battery operated and easy to raise and lower using buttons on the side The single button control central brake provides a very stable operating position A cover is supplied to protect the wheels frame Overall Carl Mk2 gives the surgeon a tailor made work environment of the highest quality Rini is constantly improving existing products and developing new ones Consequently we value the professional user s point of view so don t hesitate to let us know your opinion about any of our product lines 2 Important Before Use To ensure patient safety and the lifespan of the product it is A important to observe the following instructions before use Please read this manual carefully and unders
14. tand how to use the product before you start 2 1 Unpacking Before the product is unpacked make sure that the packaging has not been damaged during transport If so document these with a picture and report this immediately to the transport company and your local Rini representative In the packages the chair is normally in the following parts e Complete chair with wheels and seat mounted e Backrest Operatorsstol Carl Mk2 A A 2 2 J e Two armrests e Battery charger e Optional accessories e User manual Warning Be careful when lifting the chair off the pallet The chair is heavy and may cause injury Avoid bumping it this may cause material damage Remove the packing material such as plastic tape etc from the chair Warning Do not use sharp tools when removing the packaging material This may cause damage Make sure that the delivery includes all ordered parts Contact your Rini sales representative if you find any discrepancies Installation When you get the operator chair delivered it is not ready to be used It has to be mounted accordingly to this manual Place the chair on a stable floor The brake on the back wheels are normally locked at delivery and the chair is in its lowest position Release the brake yellow button on the left side of the plastic cover seen from behind and raise the chair to a suitable height yellow buttons at the front wheel Mount the backrest w

Download Pdf Manuals