1. 62 5 125 um multimode fiber optic cable for VF 45 connections Canada Department of Communications Class A This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Department of Communications Cet appareil num rique respecte les limites de bruits radio lectriques applicables aux appareils num riques de Classe A prescrites dans la norme sur le mat riel brouilleur Appareils Num rques NMB 003 dict e par le minist re des Communications BSMI Class A Taiwan te oh Fe EE PRAJE EAEN PIE gt TIRE RIE RUA gt 1038 NEUER BERK ERE TER gt VCCI Class A Compliance Japan CORE WHRMNRES SRS EMalhme VCC OBE IEJ DS ZARUMA Cd COREA RERA CPAT BR HERBIERLITLENBVUEF COMBSICSPASO IHRER bd RRENDIET User Guide CE Mark Declaration of Conformance for EMI and Safety This is to certify that this product complies with ISO IEC Guide 22 and EN45014 It conforms to the following specifications EMC EN55022 1988 CISPR 22 1985 class A EN60555 2 1995 class A EN60555 3 IEC1000 4 2 1995 4kV CD 8kV AD IEC1000 4 3 1995 3V m IEC 1000 4 4 1995 1kV power line 0 5kV signal line IEC 1000 4 6 1995 3Vrms This product complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC Safety Compliance Warning Fib
2. Accton Making Partnership Work VF 45 Slide in Modules User Guide Accton Making Partnership Work VF 45 Slide in Modules EM3564VFS Slide in Module with 4 short wavelength 850 nm VF 45 ports EM3564VFL Slide in Module with 4 long wavelength 1300 nm VF 45 ports Copyright 2000 by Accton Technology Corporation All rights reserved No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Accton Technology Corporation Accton makes no warranties with respect to this documentation and disclaims any implied warranties of mer chantability quality or fitness for any particular purpose The information in this document is subject to change without notice Accton reserves the right to make revisions to this publication without obligation to notify any person or entity of any such changes Accton International Headquarters USA Headquarters No 1 Creation Road Ill 6 Hughes Science based Industrial Park Irvine CA 92618 Hsinchu 300 Taiwan R O C Phone Numbers Phone 886 3 5770 270 Sales 800 926 9288 FAX 886 3 5770 267 Support 888 398 4101 or 949 707 4847 Internet support accton com tw RMA 800 762 4968 FAX 949 707 2460 Accton is a trademark of Accton Technology Corporation Other trademarks or brand names mentioned herein are trademarks or registered trademarks of their respective companies EM3564VFS EM3564VFL E052000 R01 150454 102 Cont
3. Connect fiber cable to the port on the newly installed module See Maximum Cable Length on page 6 in this guide for further information N ASON a vordere 8 Attach the cable to a network device Attach the male connector on the other end of the fiber cable directly to a Fast Ethernet device Be sure that the device port supports the VF 45 short wavelength or long wavelength standard depending on the module you are using 9 Power on the switch Reconnect the previously removed power sources to the switch The switch s front panel LEDs should indicate the status of the new connection Check the LED indicators for the fiber ports to ensure that they are operating correctly Refer to Fiber Port LEDs on page 2 for a description of the LED indications If the module does not respond see Troubleshooting on page 6 More details concerning the module s configuration options and network applications can be found in the switch s user guide VF 45 Slide in Modules Maximum Cable Length Cable Types and Specifications Cable Type Max Length Connector VF 45 850nm 50 125 or 62 5 125 um core multimode fiber EN Full and half duplex 300 m 984 ft VF 45 VF 45 1300 nm 50 125 or 62 5 125 um core multimode fiber Ads Half duplex 412 m 1 351 4 ft VF 45 Full duplex 2 km 1 24 mil
4. Network Interface Communication Mode Size Power Consumption Temperature Humidity Standards Compliances Emissions Immunity Warranty CSMA CD 4 VF 45 fiber EM3564VFS 850 nm short wavelength EM3564VFL 1300 nm short wavelength VF 45 connector 62 5 125 or 50 125 um multimode fiber cable Full and half duplex manual configuration 14 x 11 1 x 2 46 cm 5 51 x 4 37 x 0 97 in 9W maximum Operating 0 to 50 C 32 to 122 F Storage 40 to 158 F 40 to 70 C 5 to 95 IEEE 802 3u Fast Ethernet ISO IEC 8802 3 CE Mark FCC Class A VCCI Class A Industry Canada Class A EN55022 CISPR 22 Class A C Tick AS NZS 3548 1995 Class A IEC 1000 4 2 3 4 6 Three years VF 45 Slide in Modules EMI Certification FCC Class A Certification USA Warning This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications It has been tested and found to comply with the limits for a Class A digital device pursuant to Subpart B of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures are required to correct the interference You may use 50 125 or
5. Status TX RX On Traffic is traversing the port Full Duplex On The port is operating in full duplex mode Link On Port has established a valid network connection 100M On Transmission speed is set to 100Mbps User Guide Installing the Module Caution Do not install these modules in any unit other than the CheetahSwitch Workgroup 3508A ES3508A Contact your distributor for advice on newly released switches which may be designed for use with these modules The VF 45 Slide in Modules are field installable Just follow the instructions below Package Contents This package includes One EM3564VFS or EM3564VFL VF 45 Slide in Module e This User s Guide Owner registration card Handling the Modules Caution The EM3564VFS and EM3564VFL modules can easily be damaged by electrostatic discharge To prevent electrostatic damage observe the following guidelines e Do not remove the module from its packaging until you are ready to install it Do not touch any of the module s pins connectors or components e Hold the module only by its edges or front panel e Wear an anti static wristband connected to a suitable earth ground whenever handling the module Store or transport this module only in appropriate anti static packaging Instructions Caution The switch must be powered off before installing or replacing any module 1 Power off the switch Disconnect the AC power cord from the switch 2 Remove network c
6. ables If you are replacing a module remove the cable attached to the port on the module 3 Loosen the screws on the installed module or slot faceplate Using your fingers or a flathead screwdriver turn the screws securing the module or faceplate on the slot in a counter clockwise direction until they are free of the chassis Be sure not to completely remove the screws from the module or faceplate VF 45 Slide in Modules 4 Remove the installed module or faceplate Firmly pull on the screws until the module is free of the switch Carefully slide the module straight out of the slot Keep the original faceplate for future use If you should remove the module replace the faceplate to prevent dust and debris from entering the unit and to maintain proper air flow 5 Insert the new module into the switch Holding the new module with the text on the front panel upright carefully slide the module into the upper left slot on the rear panel and press gently until it snaps into place Be sure the new module s front panel is flush with the switch panel 6 Secure the new module Secure the new module in place by screwing the attached screws clockwise into the switch s chassis Tighten them enough to secure the module but not so tight as to prevent them from being unscrewed by hand User Guide 7 Connect the network cable to the module
7. arranty does not cover the product if it is damaged in the process of being installed Accton recommends that you have the company from whom you purchased this product install it THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY WHETHER EXPRESS IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR ANY WARRANTY ARISING OUT OF ANY PROPOSAL SPECIFICATION OR SAMPLE ACCTON SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ACCTON NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER LIABILITY 10 EM3564VFS EM3564VFL E052000 R01 150454 102
8. ents Description of Hardware VF 45 Slide in Modules Fiber Port LEDs Installing the Module Package Contents Handling the Modules Instructions Maximum Cable Length Troubleshooting Product Specifications EMI Certification FCC Class A Certification USA Canada Department of Communications Class A BSMI Class A Taiwan VCCI Class A Compliance Japan CE Mark Declaration of Conformance for EMI and Safety Safety Compliance Warning Fiber Optic Port Safety Avertissment Ports pour fibres optiques s curit sur le plan optique Warnhinweis Faseroptikanschl sse Optische Sicherheit Warranty OOOO C0ODDDADADH NOD DW WwWwwwW N gt me User Guide Description of Hardware VF 45 Slide in Modules The EM3564 VF 45 Slide in Modules are designed for use in Accton switch models which have a 4 port Fast Ethernet transceiver slot At present suitable units include the CheetahSwitch Workgroup 3508A ES3508A Detailed information about configuring these modules and advice about Fast Ethernet configuration rules can be found in the switch s user guide Safety Warning Before installing or removing the EM3564 modules first disconnect the switch from the main power supply For full safety instructions please refer to the user guide that accompanies the switch Accton s VF 45 Slide in Modules provide fiber links from a switch to remote sites These modules contain four VF 45 ports that can be connected to sites up
9. er Optic Port Safety Never look at the transmit LED through a magnifying device while it is powered on Never look directly at the fiber TX port FED Eroduet and fiber cable ends when they are powered on Class 1 Avertissment Ports pour fibres optiques s curit sur le plan optique Ne regardez jamais le voyant DEL d mission en utilisant un Dispositif LED dispositif d agrandissement tant qu il est sous tension Ne de Classe 1 regardez jamais directement le port TX Transmission a fibres optiques et les embouts de c bles a fibres optiques tant qu ils sont sous tension Warnhinweis Faseroptikanschl sse Optische Sicherheit Niemals mit einem Vergr erungsger t ein Ubertragungs LED en betrachten w hrend dieses eingeschaltet ist Niemals direkt auf deriflasse t den Faser TX Anschlu und auf die Faserkabelenden schauen w hrend diese eingeschaltet sind VF 45 Slide in Modules Warranty Accton warrants to the original owner that the product delivered in this package will be free from defects in material and workmanship for a period of three 3 years from the date of purchase from Accton or it s Authorized reseller For the warranty to apply you must register your purchase by returning the registration card indicating the date of purchase and including proof of purchase There will be a minimal charge to replace consumable components such as fuses power transformers and mechanical cooling devices The w
10. es VF 45 Maximum Fast Ethernet Network Diameter Repeater Type and Twisted Pair Twisted Pair Fiber Number 100BASE TX 100BASE TX VF 45 1 Class 200 m 656 ft 260 8 m 855 4 ft 1 Class II 200 m 656 ft 308 8 m 1012 6 ft 2 Class Il 205 m 672 4 ft 216 2 m 709 1 ft Note Network diameter is defined as the wire distance between two end stations in the same collision domain Troubleshooting If you experience any problems with the module check the following items before contacting Accton Technical Support e Ensure that the switch with the VF 45 Slide in Module is powered up e Ensure that the device attached to the module is powered up and operating correctly Ensure that the module is properly seated in the slot e Verify that the attached device is configured to match the communication mode used by the module full or half duplex e Check the connectors on both ends of the cable to be sure they are properly engaged When attaching fiber cable to an VF 45 port be sure the plug clicks into place to ensure that it is properly seated Also be sure the fiber terminators are clean You can clean the cable plugs by wiping them gently with a clean tissue or cotton ball moistened with a little ethanol Dirty fiber terminators on fiber optic cables will impair the quality of the light transmitted through the cable User Guide Product Specifications Access Method Ports Optical Wavelength
11. to 2 km 1 24 miles away with fiber cable UUUUUUUUUUUUUUUUUUUYV S EER i N EM3564VFS 850nm LU 400BASE VFS m i d EM3564VFL 1300nm A 0OBASE VFL _ __ The short wavelength VF 45 fiber port enables the EM3564VFS module to support 100 Mbps transmissions at full and half duplex over 62 5 125 or 50 125 um multimode fiber cable A fiber cable link can extend up to 300 m 984 ft and offers a cost effective solution for fiber to the desktop The long wavelength VF 45 fiber port enables the EM3564VFL module to support 100 Mbps transmissions at full and half duplex over 62 5 125 or 50 125 um multimode fiber cable A fiber cable link operating in full duplex mode can extend to remote sites up to 2 km 1 24 miles away Note The EM3564VFS short wavelength and EM3564VFL long wavelength standards are not compatible and require an end to end solution to operate correctly VF 45 Slide in Modules Fiber Port LEDs Port LEDs are provided for the module on the front panel of the switch These LEDs provide port status for at a glance network monitoring The LEDs used vary for different switch models The following table describes the key indicators for the CheetahSwitch Workgroup 3508A For a detailed description of all the indicators refer to the switch s user guide Port LEDs LEDs Condition
Download Pdf Manuals
Related Search
Related Contents
Guida per l`utente Marshall DBS 7400 User's Manual TealPaint User`s Manual CPSappl - Institut Royal de la Culture Amazighe Imation DVD/CD Duplicator CIRCUIT PETIT AS MINIMES 2012-2013 à VILLERS 6125665 Serv Galileos EN.book 日本エマージェンシーアシスタンス(6063) rental agreement can be downloaded here Manual 4038-4039-4068 Copyright © All rights reserved.