Home
SyncMOS ISP Writer SWR0002B User's Manual
Contents
1. an 7 RAR A RAKT SyncMOS Technologies International Inc SyncMOS ISP Writer SWRO002B User s Manual SyncMOS ISP Writer SWRO0002B User s Manual 1 Introduction 1 1 1 2 1 3 1 4 SyncMOS ISP Writer supports External ISP and allows users to easily program a code into SM59DXX Series and SM59RXX Series without having to program the ISP Service CODE into Target IC The product also supports SM59DXxX Series Internal ISP Supportable interfaces USB RS232 Supportable voltage for MCU Programming 5V 3 3V select from ISP Writer Jump J8 Support MCUs SM59DXX Series and SM59RXX Series Select from ISP Writer Jump J1 J2 and J3 SyncMOS ISP Writer is powered via a USB cable No external DC 5V power source is required SM59RXX Series requires 64 Pin TQFP to 40 pin DIP adaptor part No SABOO01A Please refer to article 7 SM59RXX Series Adaptor SABO001A for details on the adaptor 2 ISP Writer Accessories 2 1 2 2 2 3 ISP Writer mainboard part No SWROO02B 0 USB cable part No SAC1004A 0 64 Pin TQFP to 40 pin DIP adaptor optional part No SABO001A 0 This adaptor is required for SM59RXX Series Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 1 Ver A 2008 07 HR RAL aR A RAJ l SyncMOS Technologies International Inc SyncMOS ISP Writer SWR0002B User s Manual 3 Top View of ISP Writer 1i n f i Je
2. button again Program Iv Verify v Protect Iv ISP Connect Stop Clear Message Md 9 2 3 Press Reset button of the target board and press OK on the message window to connect the External ISP Use EWAP software interface for the on line recording task If you use SM59RXX Series which has no ISP Connect button on the software interface press SW6 button on the ISP Writer and then press Reset button on the target board to enter the ISP Mode 9 2 4 To perform off line recording press SW6 button on the ISP Writer and then press Reset button on the target board to allow MCU to enter the ISP Mode Press SW1 button on the ISP Writer and you can perform recording Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 16 Ver A 2008 07 Bf TR Bl BS AY 2k RY A RAR SyncMOS Technologies International Inc SyncMOS ISP Writer SWRO0002B User s Manual 9 3 SM59RXX Series External ISP for MCU on the target board 9 3 1 When connecting the External ISP to the target board connect Trigger to ICE_ISP_TRIGOUT on the 58th pin and Data to ICE_ISP_DATA on the 59th pin Clock to ICE_ISP_CLOCK on the 60th pin Connect the 58 59 and 60 pins which are on the IC of the target board and GND to J4 of the ISP Writer VCC can use the independent source on the target board If there is no independent source availab
3. COM1 COMIS Scanning CONT port COV Connect Success Chip Erase Success Frograr LOU Program success Protect Success Antonin Success Stop lear Ivlessage 11 Special Notes 11 1 If you click Scan COM Port and can t locate the COM PORT which connects to the PC reset the ISP Writer and then scan COM Port 11 2 When CHIP ERASE does not work try the following Check if the ISP Writer power is on Check if COM Port or USB Port is connected Check if the CHIP SELECT JUMP is correct Check VCC voltage or Press Reset button on ISP Writer Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 18 Ver A 2008 07
4. COM4 AE wad ft BSRARTE SENES HH SATB 9600 7 e etfs JECT g RARERER Eare COM4 PX VER FIFO ii HUARD TEE Ce T o i SKEREN roM J a a9 emieme D EEO J a a COM28 l COM Eep COM4 v 6 5 Select the COM PORT from COM1 to COM32 you want to set and press Ok Click Scan for Hardware Changes to initiate the COM PORT you ve just selected O REZA OX EED HTH BEW BAD e E gee B AIR a COLLINGS 9DA342 Ra DVD CD ROM Stern HE IDE ATA ATAPI 26135 Ma ACT RB U FMRE Ah OP PC HARES ane aaa F rt KRSI H iB FRPP PRE Elar EHR COM 0 LPT F ECP PR Boece PTI E j EAP lific USB to Serial Comm Port COM av Toshiba BT Port t COMIO 7 SM59RXX Series adaptor part No SAB0001 A 0 SABO0001A 0 is a 64 TQFP to 40 DIP adaptor used by SM59RXX Series The adaptor can be used in the ISP Writer or SyncMOS Easy Writer part No SWRO001A 0 See the following pictures of the adaptor Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 11 Ver A 2008 07 OME AL AR RL OAT RAA SyncMOS Technologies International Inc SyncMOS ISP Writer SWR0002B User s Manual vertical view lateral view Ahihihi 1 ny wry Si TSR NN ALULLA lt d a D 9 kaa f na S a 7 AA front
5. message will be displayed Autorun Success Chip Erase Lugi Chip Erase Success Blank Check Success Prograrn LOO Very success Protect Success 6 utonm success stop lear Iwlessage Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 8 Ver A 2008 07 MA RARROA RA A SyncMOS Technologies International Inc SyncMOS ISP Writer SWR0002B User s Manual 5 3 6 Buffer Data click Read MCU and the values read will be displayed Press Clear Window to clear the window Butter Data Checksum 1PEQOO LH OO00 55 44 55 44 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA A 0010 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 A OO20 55 44 55 44 55 AA 55 AA 55 AA 55 AA 55 AA 55 BA 0030 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA OO40 55 44 55 44 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 00S0 55 44 55 AA 55 AA 55 AA 55 AA 55 AA 55 aA 55 AA 000 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA OOTO 55 44 55 44 55 AA 55 AA 55 AA 55 AA 55 AA 55 BA 000 55 AA 55 AA 55 AA 55 AA 55 AA 55 Aa 55 AA 55 AA OO90 55 44 55 44 55 AA 55 AA 55 AA 55 AA 55 Aa 55 BA QQA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 00E0 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA 55 AA a Read WICU save Buffer Clear Window 6 How to Modify the Location of Com Port 6 1 Click My Computer Then on an empty area of the My Computer Window that pops up right click and sel
6. only available on an External ISP a ISP Block N this is used to set the size of the ISP protection area The function is only available in SM59DXX Series b Watch Dog select the WDTM parameter in the watch dog function The function is available in SM59DXX Series and SM59RXX Series c MCU speed when using SM59DXX Series you can either select the 6T mode or the 12T mode When using SM59RXX Series you can select to use the built in frequency or external frequency d BOR BOR stands for Brown Out Reset When the Vcc voltage is too low automatic reset will begin to work The function is only available in SM59DXX Series 5 3 5 Record a Chip Erase click Chip Erase and all of the code on Target IC will be deleted b Blank Check click Blank Check to check if the code on Target IC is FF c Program click Program to program the code loaded and functions set into Target IC d Verify click Verify to check the accuracy of the code programmed to the IC e Protect click Protect to encrypt the code on Target IC so that the code cannot be read by using the READ function All of the SM59DXX Series Protect codes will be read as 00 and that of the SM59RXX Series Protect will be read as FF f Autorun click the tasks you want to perform such as Chip Erase Program and so on Click Autorun to perform the tasks chosen When the recording task is completed a
7. view 7 1 How to set SAB0001A 0 JUMP the position of SM59RXX Series when programming 7 1 1 On the SAB0001A 0 adapter board are JUMP J3 J4 J5 and J6 7 1 2 JUMP J6 is used to select the VCC voltage of SM59RXX Series 7 1 3 When using this adapter board in ISP Writer part No SWROO02A 0 it is required to set JUMP J3 J4 and J5 into the ISP MODE as shown below hore mag ISP MODE setting Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 12 Ver A 2008 07 eH RARAAR RDA RDA SyncMOS Technologies International Inc SyncMOS ISP Writer SWRO002B User s Manual 7 1 4When using this adapter board in Easy Writer part No SWRO001A 0 set JUMP J3 J4 and J5 to the Writer MODE as shown below LALELE Setting of the Writer MODE 7 1 5 To perform the recording task the setting of the JUMP J6 VCC voltage must be the same as that of the JUMP J8 VCC on the ISP Writer That is if you select 5V for ISP Writer JUMP J8 voltage you have to do the same for SAB0001A Oadapter board JUMP J6 7 2 The picture below shows how SAB0001A is placed on ISP Writer How SAB0001 is placed on ISP Writer Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 13 Ver A 2008 07 LARA RAD RAS A SyncMOS Technologies International Inc SyncMOS ISP Writer SWR0002B User s Ma
8. when the IC has had an ISP service code inside the path is C Program Files SyncMOS SyncMOS Writers EWAP ISP ISP16K_EWAP_V1 hex or an External ISP SM59RXX Series only supports External ISP Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 5 Ver A 2008 07 eRARARROA RA A SyncMOS Technologies International Inc SyncMOS ISP Writer SWR0002B User s Manual c When using Internal ISP it is required to set the frequency The default value is 22 1184MHz 12T You don t have to select if you use an External ISP d Select MCU on Socket or MCU on the target board If you select Off line Record skip the part 5 3 2 Scan COM Port a Select the COM PORT COM1 or COM2 and press Scan to automatically connect ISP WRITER and the COM PORT of the PC If you select off line record you only have to select the COM PORT and don t have to perform scanning 2 pcan COM Fort com EEEE m COMI GRSEIEHE a COn GAEE b When COM PORT is located and connected The message COM2 Connect Success will appear and the software interface indicator light will flash green This varies with the PC s COM1 or COM2 City 12 Connect 5 S11CceSss stop Clear Ivlessage 2 pcan COM Fort coma GEGEE c If you use USB for connection when you open EWAP COM4 Prolific USB to Serial Com Port will appear in the SCAN CO
9. 07 OF MEAL AR RL OAT RAA SyncMOS Technologies International Inc SyncMOS ISP Writer SWR0002B User s Manual 9 The target board Connection 9 1 SM59DXX Series Internal ISP for MCU on the target board 9 1 1 When connecting the Internal ISP to the target board the ISP Writer needs to connect the target board via Rx and Tx Connect the target board Rx Tx and GND signals to J14 on the ISP Writer VCC can use the independent source on the target board If there is no independent source available on the target board the first pin VCC_OUT of J4 can serve as the power supply 9 1 2 Connect P2 6 P2 7 to GND and press Reset button on the target board to allow the target board s MCU to enter ISP Mode Use EWAP software interface to perform on line recording or press SW1 button on ISP Writer to perform off line recording 9 2 SM59DXX Series External ISP for MCU on the target board 9 2 1 When connecting External ISP with the target board the ISP Writer need to connect Data Trig Clk_out and GND on J4 with P1 0 P1 1 P1 2 on the target board and GND VCC can use the independent source on the target board If there is no independent source available on the target board the first pin VCC OUT of J4 can serve as the power supply Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 15 Ver A 2008 07 H N RAL AY A PRA a l SyncMOS Technologies Intern
10. IRFSX 0020 3 Ver A 2008 07 HR RAL aR A RAK l SyncMOS Technologies International Inc SyncMOS ISP Writer SWR0002B User s Manual 4 4 Ifyou want to program SM59RXX Series adjust J1 J2 and J3 of ISP Writer as shown below Since SM59RXX Series is in a 64 pin TQFP package the programming needs a 64 Pin TQFP to 40 pin DIP adaptor part No SAB0001A Please refer to Article 7 SM59RXX Series adaptor SAB0001A for details on the adaptor PEIE a 7 m E sinini ama feleasaheadias a mi te TP TP TP TP lO 10 IOJ 0O O 10 Oo 0 TP21 P20 T REEERE E P TP23 TP22 Zv zeH 4 5 Select the interface with the PC When using COM PORT interface connect the DC 5V power supply Turn the power on and the power indicator light will be on If you use the USB interface the USB power indicator light will also be on when the power supply is ok ia METETE oh g bbhiladaad G iper orii LEELEE J Ce E R on a When the power is on the power indicator light will be on Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 4 Ver A 2008 07 Ot R Bl RAL aR A RAR SyncMOS Technologies International Inc SyncMOS ISP Writer SWR0002B User s Manual 5 SyncMOS EWAP V2 2 Operation Instructions 5 1 Install Sync MOS EWAP V2 2 Eng Setup exe on your computer After successful installation a shortcut icon will ap
11. M port Press Scan to connect 2 Scan COM Pon Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 6 Ver A 2008 07 eRARARROA RA A SyncMOS Technologies International Inc SyncMOS ISP Writer SWR0002B User s Manual d When the COM Port cannot be located the message Please check COM port will appear which means the USB cannot be found between COM1 and COM32 or the external ISP writer is not powered Place COM Port at between COM1 and COM32 and check whether the power indicator light is on Concerning the setting of COM Port please refer to Point 6 How to Modify the Location of COM Port stop Clear Message 5 3 3 Select Program File a Click Select and Load window will pop up Click Open to select source file XXX HEX or XXX BIN Irati Value Program files Code b SM59DXX Series has a maximum ROM size of 16K SM59D04G2 and SM59RXX Series has a maximum ROM size of 64K SM59R16A2 When the CODE SIZE exceeds the maximum the message window will pop up Over the MCU program memory size Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 7 Ver A 2008 07 Bf TR Bl BS AY 2k RY A RAR SyncMOS Technologies International Inc SyncMOS ISP Writer SWRO0002B User s Manual 5 3 4 Configuration select the items you intend to set This function is
12. TEN c ay re j fs a ee j l i i ly I ly 4 Hardware Settings for ISP Writer 4 1 Connect ISP Writer to DC 5V power supply the inner side end of DC connector is positive and the outer side is negative or use the USB cable as the power source by switching the to USB POWER as shown below Using USB power as a power source Specifications subject to change without notice contact your sales representatives for the most recent information 2 IRFSX 0020 Ver A 2008 07 Bf 7 Bd Pt A 2K AD A PR A i we SyncMOS Technologies International Inc SyncMOS ISP Writer SWR0002B User s Manual election ee 5 Wa 1 7 T an O 4 4 2 Adjust VCC voltage of the MCU to be programmed JUMP J8 on the ISP Writer mainboard For example SM59DXX SeriesC25 or SM59RXX SeriesC25 stands for operation voltage SM59DXX SeriesL25 or SM59RXX SeriesL25 stands for operation voltage ESTE y A ae de 5 iy EU ey i pm iU m A atate D a g 5 ni i gt OWRU i Uz B vi 7 i ta j Ji a sift dl EAEE io select VCC Voltages for different MCU Type 4 3 If you want to program SM59DXX Series adjust J1 J2 and J3 on ISP Writer See the picture below OT TY apie me P ial i E ae s bs TURS NN c24 4 Setting of J1 J2 and J3 for programming SM59DXX Series Specifications subject to change without notice contact your sales representatives for the most recent information
13. ational Inc SyncMOS ISP Writer SWR0002B User s Manual 9 2 2 Press SW6 button on ISP Writer and D1 to D8 LEDs will begin to flash Press ISP Connect on the EWAP window A message window will pop up __ SyncMOS EWAP aag 1 Select Program Method Buffer Data i Chip SM59D0462 5V v On line Record Checksum 3F2544 H C Internal ISP Need ISP F W Extemal ISP 0000 02 0115 E4 F5 80 l2 00 F8 75 60 FF 12 00 F E4 0010 F5 90 12 00 F8 75 90 FF 12 00 FS E4 F5 40 12 00 0020 F8 75 A0 FF 12 00 F8 E4 F5 BO 12 00 F8 75 BO FF 0030 12 00 F8 75 06 60 E5 06 60 OB 12 00 D ES 06 C3 0040 13 F5 08 80 Fl 75 08 01 E5 08 60 OB 12 00 D ES 0050 08 25 EO F5 08 60 Fl 75 08 80 E5 08 60 OF F4 F5 0060 90 12 00 DB ES 08 C3 13 F5 08 80 EE 75 08 01 ES 0070 08 60 OF F4 F5 90 12 00 DB E5 08 25 EO F5 06 80 0080 EE 75 08 80 E5 06 60 OF F4 F5 AO 12 00 DB ES 086 75 08 01l E5 06 60 OF F4 F5 AO x EO FS 06 60 EE 75 08 60 E5 08 ze OO DB ES5 06 C3 13 F5 06 60 EE Clear Window C MCU on Socket MCU on Target Board 2 Scan COM Port COM COM4 Scan 3 Select Program File Bank 0 I Syncos LED_DEMO bin Select igurati 7 Please TURN OFF the target board and TURN ON sean on Then press OK button ISP Block N N 1 0 3E00 Watch Do MCU Speed 12T bd 5 Record Chip Erase Iv Autonm Pass Blank Check m Reset Failed 0 1 Press ISP Connect button If power is off or disconnected press ISP onnect
14. ect Properties The following window appears FERNET Fit re SERET e o o Windows 4 E Windows U a oe Windows AMi EERE e Update pee ees eS __ isate te oo MEERLE Tea ase Maat T Re OR pease ne Se iE ETE Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 9 Ver A 2008 07 a RA RAR RDA RD A SyncMOS Technologies International Inc SyncMOS ISP Writer SWR0002B User s Manual 6 2 Click Hardware select Device Manager and the following pops up S KER ex ee ee REO BAG 2 RA 2 DVDICD ROM seis 4 IDE ATA ATAPI 2135 E a MT ne Ai TNE TEI Er PC RARE H z HA MRS ATENE lar ie IESE a erie Sy RC ee all if FAR P RE Perel a i eRe COM FO LPT AE ECP PERE ae Ba 1EB PE PE SPIEL ISESE ASS CAD L AFIR 6 3 Select Port COM and LPT Click the COM PORT that is to be modified Right click and select Properties and the following page is displayed Prolific USB to Serial Comm Port COM4 AS e ESSE BEBET RHEE Berol o RERA Rw Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 10 Ver A 2008 07 HRARAAR RDA RDA SyncMOS Technologies International Inc SyncMOS ISP Writer SWRO002B User s Manual 6 4 Click Advanced and the following page pops up Prolific USB to Serial Comm Port
15. le on the target board the first pin VCC_OUT of J4 can serve as the power supply 9 3 2 After the connection is ready set the EWAP software interface Then you can perform the recording task 10 Update EWAP Firmware 10 1 Connect ISP Writer and open SyncMOS EWAP V2 2 Use the default setting In 1 select Program Method select External ISP and MCU On Socket in Select Chip Click Scan in 2 Scan COM Port If the connection is ok a message will be displayed COM2 connect success 10 2 Press and hold SW1 button on the ISP Writer press and hold SW2 RESET button then first release SW2 RESET button before you release SW1 button until all of the 8 LED lights off to allow SM59264 enter the Internal ISP mode 10 3 Select Firmware and then Update on the EWAP box The massage then pops up This process will change firmware 10 4 Click OK and select C Program Files SyncMOS SyncMOS Writers EWAP FW MSM9055 V21 hex Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 17 Ver A 2008 07 a7 ARAL ILD RD A SyncMOS Technologies International Inc SyncMOS ISP Writer SWRO0002B User s Manual BSED OFW fase MSM9055 21 hex Faye fe eR Ti HEE file hex ATs 10 5 AutoRun Success means successful update scanning CONT port COIA LO Please check COM port
16. nual 8 Off line record 8 1 Select the tasks you want to perform and click Execute to allow the ISP Writer record all of the source code into its MCU During the performing process LED D2 D4 D6 and D8 will flash until the tasks are all finished Then the massage will pop up Off line Success SyncHOS EWAP File Firmware Help 1 Select Program Method Buffer Data Chip sms9D04G2 Sy l Off line Record Checksum 1FE000 H ExtemalISP C IntemallsSP Freq E 2 Scan COM Port O com4 Prolific USB to Serial Comm Port v Scan 3 Select Program File Code Fiipublic Test PattemiTest Pattern 55aa_16k bi Select FEFEEEEEEEEE SEODEEEEEEE reee terepen SEETEeEEEEE et PEEEEEEEEEE FEEEEEEEEEEE lt 4 Configuration ISF Block N N 1 3E00H v Watch Dog Disable v Clear Window L J MCU Speed 12T v BOR Enable v Read 5 Record V Chip Erase V Blank Check IV Program Iv Verify V Protect Clear Message 8 2 Disconnect Com Port cable and press SW1 button to perform off line recording During the recording LED D1 D2 D3 and D4 will flash orange until the task is finished When the LEDs D5 D6 D7 and D8 turn green the off line recording task is completed E a T i i a J i i i J i Specifications subject to change without notice contact your sales representatives for the most recent information IRFSX 0020 14 Ver A 2008
17. pear on the desktop 5 2 Double click EWAP_V2 2 and the EWAP window pops up SyncMOS EWAP File Firmware Help 1 Select Program Method Butter Data Chip sm5900363 5V On line Record Checksum 3F C000 H M nemase Freq feoiisaiis OT gt FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF i FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF MCUonSocket C MICU on Target Board FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF E FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF comi GEENE Scan FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF 3 Select Program File FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF Code Select FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF 4 4 Configuration ISF Block N N 1 3E00H WatchDog Disable Read MICU save Buffer Clear Window MCU Speed E BOR Enable Read 5 Record Chip Erase f Antonin Pass D D Blank Check M Reset iC Verity a Protect fi Clear Message EWAP V2 2 Window 5 3 After the EWAP window appears do the following 5 3 1 Select Program Method a Select the MCU type on the chip SM59DXX Series or SM59RXX Series Select On line Record or Off line Record b Select Internal ISP it is available only