SHUTTER MOTOR DOOR UPS SYSTEM USER MANUAL
Contents
1. control the ON OFF of the U P S 2 DC Start Switch This is to start the UPS system from the batteries if the main power has failed In this case the Reset button must also be pressed after switching the UPS system on with the On Off switch 3 CPU Run LED This is to show the status of CPU Status LED Normal ATTBM NLAS ATTBM AUT Transfer to Battery Mode a Timer NLAS No Load Automatic Shutdown by Timer 4 System Voltage LED This is to show the 115V 230V switch position when LED light indicating 115V 230V switch is on 230V position Please make sure the equipments motors you connect to the U P S are used for 220V 240V power system The wrong position will be damaged the equipments motors 5 AC Outlet NEMA These are to be connected to the equipments motors that will be protected by the U PS 6 AC Outlet IEC This is also to be connected to the equipments motors that will be protected by the U PS 7 Emergency Light Outlet This is to be connected to the emergency light only a light is enough don t use the standard emergency light When AC power normal the outlet will no power output But when AC fail the outlet will be provide AC power to the emergency light
2. 7 Specification Model MR 400 MR 600 MR 1000 Motor Power Rating 1 4 HP 300KG 1 2 HP 550KG 1HP 1000KG Capacity TSOVA 450W 1KVA 600W 1 5KVA 900W OUTPUT Start Cap 2KVA 3KVA SKVA Voltage Same as input nominal Regulation Vrms 15 Frequency 50 60 HZ Waveform PWM Stepwave INPUT Voltage 110 220V Selectable Frequency 50 60 HZ 3 HZ BATTERY Battery Volt 24VDC 24VDC 48VDC Spec pcs 12V8AH 2pcs 12V7AH 4pcs 12V8AH 4pcs Type Lead acid Maintenance Free PROTECTION Over Voltage Line Inv 135V Inv Line 130V 110V Line Inv 270V Inv Line 260V 220V Under Line Inv 88V Inv Line 93V 110V Voltage Line gt Inv 176V Inv gt Line 186V 220V Surge Filter amp Surge Suppression meet IEEE 587 Cat A Noise Varistor clamping 150J Response greater than 20dB amp over 1MHZ for Common amp Transverse Modes Overload Fuse amp Current Limited amp Cut off Short Circuit Fuse amp Current Limited amp Cut off Low Battery Two stages no battery drain after battery cut off INDICATOR Audible Alarm AC Failure Low Battery and Overload Visible AC SW LED AC On gt Light AC Off Dark 220V LED 220V Light 110V gt Dark CPU LED Normal Slow Start Timer Fast SELECTION 115V 230V 115V position 110 120V system 230V position 220 240V system COLD START Without AC Present Force UPS by Pushing Switch EMERGENCY LIGHT Install a
3. Light It will Light while AC Failure Temperatur 0 40 degree C NVIROMENT fe Humidity 0 90 Non condensing MECHANICAL WxHxD mm 275 x 250 x 150 340 x 310 x 150 340 x 310 x 150 Weight 15 0 KGS 20 0 KGS 25 0 KGS SHUTTER MOTOR DOOR UPS SYSTEM MR400 MR600 MR1000 iin ge Hayy mi Ins On USER MANUAL IMPORTANT SAFETY INSTRUCTION This manual contains important instructions that should be followed during installation and maintenance of the U P S and batteries Read this manual thoroughly before operation If apparent damage to the unit is found upon unpacking return the unit to your dealer for proper handling Technical service to the unit should be done by an authorized personnel Unauthorized service by the users will void the WARRANTY The U P S is designed for 115V 230V equipments use Please make sure the 115V 230V selection switch is on right position before using it Keep this unit away from wet areas Do not leave the unit in direct sunlight While cleaning do not apply any chemical solvent to the unit Dry cloth is preferred to avoid any dripping into the circuit This unit is intended for installation in a temperature controlled indoor area free of conductive contaminants SAVE THESE INSTRUCTIONS 6 Maintenance 6 1 Operation The UPS system contains no user serviceable parts If the battery service life 3 5 years at 25 C ambie
4. ith a VDE tested CE marked or UL marked mains cable e g the mains cable of your computer 3 Fully charge the batteries of the UPS system by leaving the UPS system connected to the mains for 4 hours You can also use the UPS system directly without charging it but the stored energy time may then be shorter than the nominal value specified Note The UPS system charges the batteries automatically as soon as it is connected to a wall receptacle and the On Off switch is set to the ON 4 Connect your computer to the UPS output sockets by using the enclosed power cord Caution 1 Do not connect appliances or equipments that would overload the UPS system to the UPS output sockets 2 Please make sure that the position of UPS 115V 230V SW is on the right position For samples if your AC power is 110 120V system please place the SW on 115V position if your AC power is 220 240V system please place the SW on 230V position 5 Set the On Off switch on the unit right panel to position ON 6 Test the UPS system by disconnecting the input power cord of the UPS system from the wall receptacle Caution The output sockets of the UPS system may still be electrically live even if the mains supply has been disconnected or the mains cable has been disconnected 3 Layout amp Description Right left and inside view MR 400 MR 600 MR 1000 CNODOUOONONOOD fag QODD0O00000000 QODDDO000000000 1 Power Switch This is to
5. mber 2 Date on which the problem occurred 3 Detailed description of the problem Contents 1 Introduction 4 2 Installation and Operation 5 3 Layout amp Description 6 4 Indicators and Operating Controls 9 5 Troubleshooting 10 6 Maintenance 11 7 Specification 12 1 Introduction The super UPS MR Series is a newly developed 4 Indicators and Operating Controls Line Interactive system with simulated sine wave for Switches Function uninterruptible power supply The MR Series UPS is design buttons for home use purpose It can be used for the home electrical 1 Switches the UPS system on and off appliances even motor appliances The MR Series UPS also On Off e UPS system is switched on if switch is on 1 with a emergency light outlet user can install a light or bulb switch on position instead of the emergency light or emergency exit light Its front panel UPS system is switched off if switch is on 0 features as below position Starts the UPS system from the batteries if the AC Easy Installation and Repair power has failed In this case the DC start switch Cold Start Function DC start must also be pre
6. nt temperature has been exceeded the batteries must be exchanged Please consult your dealer in this case 6 2 Storage If the batteries are to be stored in temperate climatic zones they should be charged every three months for 8 hours You should shorten the charging intervals to two months at locations subject to high temperatures 5 Troubleshooting If the UPS system does not operate correctly please attempt to solve the problem using the table below No output voltage On Off switch in Set the On Off switch to or no indication or position 0 OFF position 1 ON UPS remains on battery mode even if the AC line normal and main switch ON Line side fuse of Check the load If an UPS system overload has occurred defective reduce the number of loads and then check the line side fuse and exchange it if necessary by pushing it No input voltage Check wall receptacle check input power cord UPS system issues UPS system Reduce the number of acoustic alarm overload loads connected to the every second when UPS output normal mode Stored energy time Batteries not fully Charge the batteries for less than nominal charged batteries at least 4 hours Check value or no stored defective capacity If the problem energy time still persists please consult your dealer Please have the following information ready at hand before calling the After Sales Service Department 1 Model number serial nu
7. ssed after switching the UPS system Powerful Start Capacity a on with the On Off switch In this case do not switch Smart Battery Testing on the loads connected to the output of the UPS system until approx 20 seconds after the UPS system Manual Selection for 110V or 220V System has been started OUPS Emergency Light Function Over 32 Hours Standby time Smart Overload and Short Circuit Protection 2 Switches off the audible alarm in battery mode CPU state Indicates the status of the CPU Low Battery Voltage Alarm een e Normal Refer to page 4 3 CPU Run LED Low Battery Cut off Automatically g e ATTBM Activity Refer to page 4 3 CPU Run LED O No Load Automatic Shutdown by Timer diode LED e NLAS Activity Refer to page 4 3 CPU Run LED Auto Transfer to Battery Mode by Timer 115V 230V The following information is displayed Option for AVR Function switch state LED li ghts switch is on 230V position Option for External Battery Bank indicator light emittin LED darks switch is on 115V position g diode LED Operating Indicates the status of the UPS system state indicator l l l buzzer BZ operation via batteries beeping every 4 seconds operation via mains BZ silence operation via batteries low stage beeping every half second 8 AC Inlet This is to be connected with the enclosed AC power cord for plugging into the wall receptacle 9 AC Input fuse This is
8. to disconnect line input to protect outlets from over load or short circuit A spare fuse is also enclosed for possible replacement purpose 10 External Battery Socket option This is to be connected to the external battery pack to extend the backup time Please make sure the external battery voltage is same as the U P S specification For examples D750 D1000 is 24V and D1500 is 48V 11 DIP Switch on main PCB Inside the Case This is to setting the Green Function ATTBM Function and NLAS Function ajaja IN Green Function Setting ON gt Disable OFF gt Enable ATTBM Timer Setting ON 10 sec OFF gt 30 days NLAS Timer Setting ON gt 5 min OFF Disable Remark ATTBM Auto Transfer to Battery Mode by Timer NLAS No Load Automatic Shutdown by Timer Option for a remote controller Green Function Enlarge Stand by Time and Enable Powerful Start Capacity 12 System Voltage Selection Switch Inside the Case This is to select the system operating voltage Please make sure the equipment motors you connect to the U P S are used for 110 120V or 220V 240V power system The wrong position will be damaged the equipment motors 2 Installation and Operation 1 Inspect the packaging carton and its contents for damage Please inform the transport agency immediately should you find signs of damage Please keep the packaging in a safe place for future use 2 Connect the UPS system to a wall receptacle w