1. 6347 72450 ap lotta 1 OHH EITE p E D 4 ZUTE Y Y D Es gt apo gan yA MG 1 Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping If any damage is discovered repack the unit and return it to the place of purchase 2 Charging This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during shipping and the battery should be recharged prior to use Turn on the UPS Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 6 hours with no load no electrical devices such as computers monitors etc connected eel BEREK III 3 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high ZO y E On the other hand place the UPS away from the monitor at least 20cm to avoid interference 20mm 4 Connection Plug the UPS into a 2 pole 3 wire grounded receptacle Then connect on
2. assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA e Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible INTRODUCTION This UPS is specially designed for Personal Computer with multi functions Its light weight compact design perfect fits to the limited working environment The line of UPS is equipped with boost and buck AVR to stabilize input voltage range It is also built in with DC start function This function enables the UPS to be started up without AC power supplied Although it s a small UPS The main features of Aurora UPS are listed below e Microprocessor control guarantees high reliability e Equipped with Boost and Buck AVR e Green Power Function for energy saving e DC Start Function e Auto restart while AC recovery e Compact size Light Weight e Provides AC Overload protection TROUBLE SHOOTING Symptom Possible Cause Remedy No LED display on 1 Battery weak 1 Charge battery up to 8 hours the front panel 2 Battery defect 2 Replace with the same type
3. ptional The 1st to 3th green Led lighting to indicate load level LED1 green gt 66 load level LED2 green gt 33 load level LED3 green gt 0 load level Backup Mode Green flashing The 4st green blinking Optional The st to 3th green Led lighting to indicate battery capacity LED1 green battery voltage gt 12 5V LED2 green battery voltage gt 11 5V LED3 green battery voltage gt 10 5V AUDIBLE ALARM IBackup Mode Sounding every 10 seconds Low Battery Sounding every 1second Overload Sounding every 0 5 second Fault Continuously sounding PROTECTION Full Protection Discharge overcharge and overload protection PHYSICAL Dimension mm DXWXH 365 L x139 W x195 H WEIGHT Net Weight 8 6kgs 10 2kgs ENVIRONMENT Operating Environment 0 C 40 C Noise Level Less than 40dB
4. User s Manual Ss IO UI DIN airi ibi eia beko AURORA 1 2K 2 2K Uninterruptible Power System Safety CAUTION This UPS utilizes voltages that may be hazardous Do not attempt to disassemble the unit The unit contains no user serviceable parts Only factory service personnel may perform repairs Internal battery voltage is 24Vdc Sealed lead acid 6 cells battery two pcs Connection to any other type of receptacle other than a two pole three wire grounded receptacle may result in shock hazard as well as violate local electrical codes In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment mi
5. crowave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent Do not dispose of batteries in a fire as they may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hands 2 Use tools with insulated handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminals e Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same number and type of sealed lead acid battery The maximum ambient temperature rating is 40 C e This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen e During the installation of this equipment it should be
6. e computer related device into each of the power receptacles supplied on the back of the UPS 5 Turn On Off To turn on the UPS unit press the power switch lightly To turn off the UPS unit press the power switch again 6 DC Start All Aurora Series are equipped with DC Start To start the UPS when AC utility power is not available simply press the power switch 7 Green Power Function All Aurora UPS is equipped with Green Power Function For saving power and protecting battery the method of deep discharging protection is adopted on inverter mode ZIEN EEES SPECIFICATION MODEL AURO 1200 2200 CAPACITY JANN 1200VA 600W 2200VA 1100W INPUT SER 120VAC or 230VAC oltage Range 85 145VAC or 170 280VAC OUTPUT oltage 110 120VAC or 220 230 240VAC lege Regulation Batt Mode 10 Frequency 50Hz or 60Hz Frequency Regulation Batt Mode 1 Hz Output Waveform Modified Sine wave BATTERY Battery Type 12V7Ah x 2 12V 9Ah x 2 Recharge Time 6 hours to 90 after complete discharge TRANSFER TIME Typical 4 8 ms INDICATOR IAC Mode Green lighting The 4st Green Led Lighting
7. of battery 3 Power switch is not pressed 3 Press the power switch again continuously when AC supply is normal Alarm buzzer beeps Overload of the UPS Verify that the load matches the UPS capability specified in the specs When power failure 1 Overload of the UPS 1 Remove some non critical load back up time is 2 Battery voltage is too low 2 Charge battery 8 hours or more shorten 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery Mains normal but LED is flashing Power cord is loose Reconnect the power cord properly If any abnormal situations occur that are not listed above please call service people immediately SYSTEM DESCRIPTION Front panel 1 Power Switch 2 LED Indicators AC Mode Green lighting Battery Mode Green flashing 3 Fault LED 4 LED Indicators AC Mode Load Level LEDs Battery Mode Battery Capacity LEDs Back Panel 1 AC input 2 Output receptacles 3 USB amp RJ45 communication