OPERATING INSTRUCTIONS MANUAL FOR “V” PUMPS

image

Contents

1. B DIMENSIONS mm inches A 106 96 4 21 B 210 44 8 28 C 199 44 7 85 D 114 50 4 50 E 187 96 7 40 F 97 00 3 81 G 106 96 4 21 H 125 47 4 93 L 50 00 1 96 M 201 00 7 91 D Appendix Dimensions 25 E Appendix Chemical Compatibility Table Solenoid driven metering pumps are widely used to dose chemical fluids and it is important that the most suitable material in contact with fluid is selected for each application This compatibility table serves as a useful help in this respect All the informations in this list are verified periodically and believed to be correct on the date of issuance All the informations in this list are based on manufacturer s data and its own experience but since the resistance of any material depends by several factors this list is supplied only as an initial guide in no way EMEC makes warr
2. 19 RC R 20 PUA DO CMON ODDS 21 B Appendix Construction Materials and Technical 22 Appendix D livery CUTVES 23 C Appendix Delivery UE uu 24 C Appendix Delivery Curves Self Venting cccccccsseccccecseseeeeeceeeeeeeeeseeseeeeesseeeeeeeeeseeeeseeseseauseeeeeeaas 25 D Appendix 26 E Appendix Chemical Compatibility 27 G Appendix V series pump exploded view 28 Appendix 31 Technical features and drawings are subject to changes and modifications without any advice 31 When dismantling a pump please separate material types and send them according to local recycling disposal requirements We appreciate your efforts in supporting your local Recycle Environmental Program Working together we ll form an active union to assure the world s invaluable resources are conserved
3. See chemical compatibility table If dosing product is not listed please consult full Compatibility Table or contact chemical s manufacturer 5 Installation draw Pump must be installed in a stable support at a maximum height from tank s bottom of 1 5 meters ul 1 Dosing Pump 2 Suction Hose E TIL a 4 Injection Valve 5 Air discharge 6 Level Probe 6 7 Foot Filter 8 Power Cable 6 Hydraulic Installation Hydraulic connections are Suction Hose with level probe and foot filter Delivery Hose with injection valve Discharge Hose Suction Hose Completely unscrew tightening nut from pump s head and remove assembling components tightening nut holding ring and pipe holder Assembly as shown in fig A Insert hose into pipe holder until it reaches the bottom Lock hose on pump s head by screwing down the tightening nut Use only hands to do it Connect other side of the hose to the foot filter using the same procedure Suction Hose Tightening Nut Holding Ring Pipe Holder O ring Valve fig A 6 Hydraulic Installation Assembling foot filter with level probe Delivery Hose Level probe must be assembled with foot filter using the provided kit Foot valve is made to be installed into tank s bottom without sediments priming problem STEP 4 INSERT RING AS SHOWN STEP 3 INSERT PROBE WITH N O CONTACT UNTIL TO HEAR A CLICK STEP 2 INSERT FLOATER ST
4. This operating instructions contains safety information f N that if ignored can endanger life or result in serious 5 injury They are indicated by this icon xl N Use of this pump with radioactive chemicals is for N bidden OPERATING INSTRUCTIONS MANUAL FOR V PUMPS N Keep the pump protected from sun and water Avoid water splashes English language Read Carefully R2 03 09 Danger Caution V series solenoid dosing pumps comply with the following European regulations EN60335 1 1995 EN55014 EN50081 1 2 EN50082 1 2 EN6055 2 EN60555 3 Based on directive CEE 73 23 c 93 68 DBT Low voltage directive and directive 89 336 CEE EMC Electromagnetic Compatibility GENERAL SAFETY GUIDELINES In emergencies the pump should be switched off immediately Disconnect the power cable from the power supply When using pump with aggressive chemicals observe the regulations concerning the transport and storage of aggressive fluids When installing always observe national regulations Manufacturer is not liable for any unauthorized use or misuse of this product that may cause injury damage to persons or materials Pump must be accessible at all times for both operating and servicing Access must not be obstructed in any way Feeder should be interlocked with a no flow protection device Pump and accessories must be serviced and repaired by qualified and authorized personnel only Always d
5. h at 5bar counter pressure rotate front panel knob to 50 VCO has a divider x 0 1 to reduce by ten times the pump capacity by dividing the pump stroke speed How to enable divider mode set the pump into OFF mode keeping pressed the on off button wait 3 flashes from the status led The pump will start the dosing activity with the stroke speed reduced ten times than the value set on stroke lenght knob To disable the divider mode power OFF the pump Keeping pressed the on off button wait 3 flashes of the status led on off button stroke lenght knob status led LED The led on the frontal panel shows the pump s operating status through 5 flashing LED ACTIVITY PUMP S STATUS It flashes 3 times per second the pump is powered with a power supply lower than the label It flashes 2 times per second the pump is powered with a power supply higher than the label It flashes 1 time every 2 seconds the pump is in pause OFF and it is powered OFF mode led ON it switches off when pump strokes led ON it switches off 1 time the pump is working into DIVIDE mode every 2 seconds the pump is active and functioning ON VCOG is automatic priming model when the pump is working ON keep pressed on off key for 7 seconds The pump starts priming Leave the key to turn off the pump OFF 9 Models VCL Constant dosing pump with level alarm A red led indicates that the product s tank is empty During this cond
6. pump OFF 16 MANUAL PRIMING DISCHARGING 1 Connect the pump to main power 2 Rotate front panel knob to 7096 3 Turn on the pump 4 Rotate discharge knob open it completely 5 The chemical will begin to flow into discharge hose Close the discharge knob 6 Proceed to normal operating mode 10 Priming 17 11 Troubleshooting PROBLEM Pump doesn t turn on Pump is not dosing and solenoid is operating Pump is not dosing and solenoid isn t operating or slightly operating POSSIBLE CAUSE Pump isn t powered Connect it to main supply Pump s protection fuse is broken Replace it See page 19 for replacement procedure Pump s main board is broken Replace it See page 19 for replacement procedure The foot filter is obstructed Clean it Suction hose is empty Pump must be primed Repeat priming procedure Air bubbles inside hydraulic circuit Check valves hoses fittings Product to dose is generating gas Turn discharge knob and let air flow away Use a Self venting pump head Crystals presence inside valves Check them and try to dose 2 3 liters of normal water Change valves Injection valve obstructed Change it 18 12 Fuse and main board replacement Fuse or main board replacement is allowed to qualified personnel only Before to operate disconnect the pump from main power and all hydraulic connections For fuse replacement is necessary to use a 3x16 and 3x15 s
7. 10 0 93 10 0 00024 2 64 0 93 5 bar 72 PSI 0512 1 11 12 0 00029 3 17 1 11 5 bar 72 PSI 0408 0 74 8 0 00019 2 11 0 74 4 bar 58 PSI 0310 0 93 10 0 00024 2 64 0 93 3 bar 43 PSI 0217 1 57 17 0 00041 4 49 1 57 2 bar 29 PSI Pump Head J i Ix Lu h R5 Ch 4 f Ch n j Ch 00 L LLLLILLLILLLIIS 1 1 ST 1111111111111111 35 1 11111111111111 5 3 T B 11 18 18 tT TTT TT e 5 5 IL LI LLLI LI llll Lei lm Eee ee amp B 10 11 12 15 14 18 C Appendix Delivery Curves Pump Head K e 1111111111 1 2 dct 5 8 123344 19 151 P718 Pump Head K NL Iun LL LL LE LLL SEE 5 3 23 C Appendix Delivery Curves Pump Head K Pump Head K Flow rate indicated is for H O at 20 C at the rated pressure Dosing accuracy 2 at constant pressure 0 5 bar 24
8. EP 1 INSERT RING AS SHOWN 056 0003 3 9 8180 pcno 3 3999 8 Connect BNC from level probe into pump s level input front side of the pump Put level probe assembled with foot filter into tank s bottom Warning If there is a mixer installed into tank install a suction lance instead of level probe foot filter Completely unscrew tightening nut from pump s head and remove assembling components tightening nut holding ring and pipe holder Assembly as shown in fig A Insert hose into pipe holder until it reaches the bottom Lock hose on pump s head by screwing down the tightening nut Use only hands to do it Connect other side of the hose to the injection valve using the same procedure 7 Pump head Injection Valve Injection valve must be installed on plant from water s input Injection valve will open at pressure greater than O 3bar Discharge hose Insert one side of discharge hose into discharge connector as shown in fig C Insert other side of discharge hose into product s tank During priming procedure product exceeding will flow into tank To Delivery hose Discharge Knob Discharge hose To Suction hose fig C For priming procedure see the related chapter 10 7 1 Self venting pump head Self venting pump head to bleed hose to delivery hose to suction hose Self venting pump head must be used when using chemicals that produce gas i e hydrogen peroxide ammon
9. anties of any matter respect to the informations provided in this list Chemical Formula Ceramic PVDF PP PVC 85 316 PMMA Hastelloy PTFE FPM EPDM NBR PE Acetic Acid Max 7596 CH COOH 2 1 1 1 1 3 1 1 3 1 3 1 Aluminium Sulphate Al SO 1 1 1 1 1 1 1 1 1 1 1 1 Amines R NH 1 2 1 3 1 1 1 3 3 1 1 Calcium Hydroxide Lime Milk Slaked Lime Ca OH 1 1 1 1 1 1 1 1 1 1 1 1 Calcium Hypochlorite Chlorinated Lime Ca OCl 1 1 1 1 3 1 1 1 1 1 3 1 Copper lI Sulphate Roman Vitriol CuSO 1 1 1 1 1 1 1 1 1 1 1 1 Ferric Chloride FeCl 1 1 1 1 3 1 1 1 1 1 1 1 Hydrofluoric Acid 4096 HF 3 1 1 2 3 3 2 1 1 3 3 1 Hydrochloric Acid Concentrate HCI 1 1 1 1 3 1 1 1 1 3 3 1 Hydrogen Peroxide 30 Perydrol H O 1 1 1 1 1 1 1 1 1 2 3 1 Nitric Acid 65 HNO 1 1 2 3 2 3 1 1 1 3 3 2 Phosphoric Acid 50 Orthophosphoric Acid H PO 1 1 1 1 2 1 1 1 1 1 3 1 Potassium Permanganate 10 KMnO 1 1 1 1 1 1 1 1 1 1 3 1 Sodium Bisulphite NaHSO 1 1 1 1 2 1 1 1 1 1 1 1 Sodium Carbonate Soda Na CO 2 1 1 1 1 1 1 1 2 1 1 1 Sodium Hydroxide Caustic Soda NaOH 2 1 1 1 1 1 1 1 2 1 2 1 Sodium Hypochlorite 12 596 NaOCl NaCl 1 1 2 1 3 1 1 1 1 1 2 1 Sulphuric Acid 85 H SO 1 1 1 1 2 3 1 1 1 3 3 1 Sulphuric Acid 98 596 H SO 1 1 3 3 3 3 1 1 1 3 3 3 Resistance rating Resistant 1 Fairly resistant 2 Not resistant 3 Materials Polyvinyldene fluoride PVDF Pump H
10. connect BNC and external signal to pump s INPUT connectors Level Probe Input bottom view Level Probe Input available on VCL 13 9 Models LEVEL ALARM CL type pumps are provided with a liquid level alarm to indicate product tank is empty The level probe is connected to the right BNC plug on pump s bottom panel The level probe is made of a N O reed contact 10VA 1A max 230Vac max closed by a floating magnet housed in a PP plastic box When the product level goes below the minimum the magnet closes the reed contact The pump stops and the red LED on pump s front panel indicates the alarm status PUMP TYPES Pumps mod VCLF and 12 24 are equipped with a bicolour led Led on red colour low level product alarm Check product s tank and restore the level Led on blinking green colour pump normal operating mode Led on blinking green colour one second on one second off power supply out of range Check pump s label and check the main power 14 9 Models lt Constant pump with flow control front panel knob may be set from 0 to 100 of pump nominal capacity Flow control is electronically set and it operates on pump injections number To avoid linearity problem do not set the knob of pump flow between 096 and 1096 VCO may operate in constant dosing mode or On Off mode using an external signal Dosing example using an VCO 0505 to dose 2 5 I
11. crewdriver and a new fuse same model of old one For main board replacement is necessary to use a 3x16 and 3x15 screwdriver and a new main board same model of old one Fuse replacement procedure Remove 6 screws from pump s back Pull pump s back cover until it s completed separated from pump s front Be careful of the knob s spring Locate the blown fuse and replace it Reassemble the pump Reinsert screws Main board replacement procedure Remove 6 screws from pump s back Pull pump s back cover until it s completed separated from pump s front Be careful of the knob s spring Remove board s screws Completely disconnect wires from main board and replace it Reinsert screws Reconnect wires to the main board see enclosed picture Reassemble the pump Reinsert screws 19 13 Main board Power supply Solenoid VCL Solenoid 20 A Appendix Maintenance During normal operating mode pump must be checked once for month Wear needed safety devices and check hoses and all hydraulic components for product leak broken hoses corroded connections All maintenance operations must be performed by authorized and trained personnel only If pump needs factory assistance please use original package to return it Before to do it please remove all dosing product inside the pump and hoses Use only original spare parts 21 B Appendix Construction Materia
12. description On Off button On Off Led Pump s pulses Discharge knob Suction valve Note otroke speed knob Delivery valve Level Probe Input shown image does not represent a specific pump s model It is only for general purpose 4 Before to Install warnings Pump s installation and operativity is performed in 4 main steps Pump s installation Hyaraulic Installation hoses level probe injection valve Electrical Installation main power connection priming Programming the pump Before to start please read carefully the following safety information IProtective clothes Installation location Hoses and Valves Wear always protective clothes as masks gloves safety glasses and further security devices during ALL installation procedure and while handling chemicals Pump must be installed in a safety place and fixed to the table wall to avoid vibration problems Pump must be installed in a easy accessible place Pump must be installed in horizontal position Avoid water splashes and direct sun Suction and delivery hoses must be installed in vertical position All hoses connections must be performed using only hands force No tongs required Delivery hose must be firmly fixed to avoid suddenly movements that could damage near objects Suction hose must be shorter as possible and installed in vertical position to avoid air bubbles suction Use only hoses compatibles with product to dose
13. eads valves fitting tubing Polypropylene PP Pump Heads valves fitting level floater PVC PVC Pump Heads Stainless steel SS 316 Pump Heads valves Polymethyl Metacrilate Acrylic PMMA Pump Heads Hastelloy C 276 Hastelloy Injection valve spring Polytetrafluoroethylene PTFE Diaphragm Fluorocarbon Viton B FPM Sealings Ethylene propylene EPDM Sealings Nitrile NBR Sealings Polyethylene Tubing 26 G Appendix V series pump exploded view NOTICE always specify the pump s label when ordering spare parts 27 28 29 30 H Appendix Summary Summary TTCE 3 te 4 o Genra CCS ON OOM RE m 5 4 Before to Install warnings ee er ee ae ree ree 6 Se LUN OFAN CUA eee ihe Pata Emm 7 OFV NSE ION a EE E E O 8 a WE TM NS AO e E EE E E ER E E EA E A 10 FM Self venting pump hedd s mmm 11 7 ICCC al IN STAN AM TED 12 Cs CNN 14 cee 17 10 11 11 09 6 0 18 11 Fuse and main board
14. ischarge the liquid end before servicing the pump Empty and rinse the liquid end before work on a pump which has been used with hazardous or unknown chemicals Always read chemical safety datasheet Always wear protective clothing when handling hazardous or unknown chemicals Introduction Pump capacity 1 Introduction V Series metering pumps are the ideal solution for low middle dosing of chemicals All control and setup parameters are available using accurate control knobs and a visual system led V Series metering pumps have digital On Off switch to ensure dosing activities available on some models only Flow rate is determined by the stroke speed frequency adjustment The stroke speed is adjustable from 0 to 100 using the adjustment knob However dosing accuracy is guarantee within an adjustment range from 3096 to 100 The led on the panel shows the status activity of the pump 2 Unpacking Included into package n 4 Dibbles 06 n 4 Self tapping screws 4 5 x 40 n 1 Delayed fuse 5 X 20 n 1 Foot filter with valve n 1 Injection valve n 1 Level probe not included in VCO model m 2 Delivery pipe opaque PE m 2 Suction pipe transparent PVC m 2 Discharge pipe transparent PVC 4x6 n 1 This installation manual If hose is 6x8 then there is only a 4mt long hose Cut to obtain suction and delivery hoses eS At PLEASE DO NOT TRASH PACKAGING IT CAN BE USED TO RETURN THE PUMP 3 General
15. ition the pump does not dose The pump has flow control front panel knob may be set from 096 to 10096 of pump nominal capacity Flow control is electronically set and it operates on pump injections number To avoid linearity problem do not set the knob of pump flow between 0 and 10 VCL has a divider x 0 1 to reduce by ten times the pump capacity by dividing the pump stroke speed How to enable divider mode set the pump into OFF mode keeping pressed the on off button wait 3 flashes from the status led The pump will start the dosing activity with the stroke speed reduced ten times than the value set on stroke lenght knob To disable the divider mode power OFF the pump Keeping pressed the on off button wait 3 flashes of the status led t stroke lenght knob LED The led on the frontal panel shows the pump s operating status through 5 flashing on off button status led level alarm Three times per second blinking RED Too low power supply Two times per second blinking RED Too high power supply One time every 2 seconds blinking GREEN OFF mode Pump powered One time every 2 seconds blinking into DIVIDE mode ORANGE Always ON GREEN but off when pump strokes ON mode Pump powered Always ON ORANGE but off when pump strokes into DIVIDE mode VCLG is automatic priming model when the pump is working ON keep pressed on off key for 7 seconds The pump starts priming Leave the key to turn off the
16. ium sodium hypoclorite at particular conditions Hoses assembling procedure including purge hose is described in fig A Notes suction delivery and purge valves are DIFFERENT Do not exchange them delivery and purge hoses are made of same material it s allowed to lightly bend discharge hose during calibration procedure TEST insert discharge hose into BECKER test tube 11 8 Electrical installation All electrical connections must be performed by AUTHORIZED AND QUALIFIED personnel only Before to proceed please verify the following steps verify that pump s label values are compatible with main power supply pump must be connected to a plant with a differential switch 0 03A sensitivity if there isn t a good ground to avoid damages to the pump do not install it in parallel with heavy inductance load for example engines A relay switch must be used See below picture I R P Dosing Pump R Relay Switch or safety device E Electrovalve or inductance load A Main Power On pump s mother board there is a further protection against over voltages 275V 150V and distribution line noises 4KV for max 50usec as shown Vpk 4KV 0 9 Vpk 0 5 Vpk 1 45 50 uS 12 8 Electrical Installation Once verified previous steps proceed as follows check that of level probe has been connected as described in Hydraulic Installation chapter
17. ls and Technical info TECHNICAL FEATURES Power supply 230 VAC 180 270 VAC Power supply 115 VAC 90 135 VAC Power supply 24 VAC 20 32 VAC Power supply 12 VDC 10 16 VDC Pump strokes 0 180 Suction Height 1 5 metres Environment Temperature 0 45 C 82 113 F Chemical Temperature 50 C 32 122 F Installation Class II Pollution Level 2 Audible Noise 74dbA Packaging and Transporting Temperature 10 50 C 14 122 F Protection degree IP65 MANUFACTURING MATERIALS Case PPO Pump head PVDF Diaphragm PTFE Balls CERAMIC GLASS PTFE SS Suction Pipe PVC Delivery Pipe PE Valve Body PVDF O ring FP EP WAX SI PTFE Injection connector PP PVDF ceramic HASTELLOY C276 spring Level Probe PP PVDF Level probe cable PE Foot Filter PE PVDF as ordered 22 INFORMAZIONI Portata cc per impulso Pressione massima cc h Maxl h Min GPH GPH 2001 0 1 1 0 00002 0 26 0 1 20 bar 290 PSI 1802 0 19 2 0 00005 0 52 0 19 18 bar 261 PSI 1804 0 37 4 0 00009 1 05 0 37 18 bar 261 PSI 1502 0 19 2 0 00005 0 52 0 19 15 bar 217 PSI 1504 0 37 4 0 00009 1 05 0 37 15 bar 217 PSI 1505 0 46 5 0 00012 1 32 0 46 15 bar 217 PSI 1004 0 37 4 0 00009 1 05 0 37 10 bar 145 PSI 1005 0 46 5 0 00012 1 32 0 46 10 bar 145 PSI 1010 0 93 10 0 00024 2 64 0 93 10 bar 145 PSI 0706 0 56 6 0 00014 1 58 0 56 7 bar 101 PSI 05