Home
USER CONTROLS GENERAL INFORMATION WARRANTY DSL
Contents
1. 6 Connect the wires from your system to the thermo stat terminals as shown in the wiring diagrams Carefully dress the wires so that any excess is pushed back into the wall cavity or junction box Ensure that the wires are flush to the plastic subbase The access hole should be sealed or stuffed to pre vent drafts from the wall affecting the thermostat REPLACING THE THERMOSTAT ON THE SUBBASE 1 Position the thermostat on the hinged tabs located at the top of the subbase 2 Gently swing the thermostat down and press on the bottom center edge until it snaps in place Line Voltage 24 VAC Transformer ala A lt OFF ON gt 4 MINUTE 2 MINUTE MIN ON OFF MIN ON OFF KEYBOARD UNLOCKED KEYBOARD LOCKED OUTPUT TERMINAL FUNCTIONS RH 24 VAC supply from heating equipment WwW Heat energized with a heating call Model DSL 100 111 123 97041
2. 111 123 DSL 100 Heat Only Thermostat OPERATING INSTRUCTIONS SEE REVERSE FOR INSTALLATION INSTRUCTIONS This page intentionally left blank Your new digital thermostat has been designed to provide accurate control and display of room temper ature In addition it will also display all relevant infor mation pertaining to your system The clearly marked buttons and informative display make it extremely easy to understand and simple to use Please take a few moments to read the brief instruc tions and familiarize yourself with the various func tions in order to obtain maximum benefit from this truly unique electronic control GENERAL INFORMATION The thermostat normally displays room temperature mode of operation and whether heating is currently on The two buttons on the front of the unit allow complete control of the equipment Raising or lowering the setpoints in heating is as sim ple as pushing a button In addition you may choose to display the temperature in F or C POWER FAILURES Your thermostat employs the latest developments in solid state electronic technology One of the unique features of your thermostat is that there is no battery required to maintain your selected setpoints in the event of a power loss as the memory is unaffected by power failures of any duration When power is restored the thermostat will continue operating as if the power had never been off TEMPERATURE ACCU
3. RACY Full temperature accuracy will be realized only after the thermostat has been installed and powered for at least one hour USER CONTROLS MODE The DSL 100 thermostat is a heat only control and is permanently in the heat mode HEATING Select the temperature you want your equipment to maintain while in the heating mode by pressing either the V or A buttons CELSIUS FAHRENHEIT Simultaneously press V or A to switch between Celsius and Fahrenheit temperature display LIMITED OVERRIDE When the keyboard is locked switch 2 ON the user may override the temperature setpoint for 1 hour by pressing either the V or A button The range of tem perature override is 6 F or 3 C from the pro grammed daytime setpoint WARRANTY LIMITED TWO YEAR WARRANTY The manufacturer warrants to the original purchaser that its product and component parts will be free from defects in workmanship and materials for a peri od of two years from the date of purchase Your deal er will provide free replacement of your DSL thermostat upon proof of purchase EXCLUSIONS This warranty does not apply in the event of misuse abuse or as a result of unauthorized alterations or repairs The manufacturer will not be liable for any consequential damages including without limitation damages resulting from defects loss of use or misuse This equipment if installed in strict accordance with the manufactur er s instructions complies with the
4. asurement 28 to 124 F or 0 to 48 C Range Control 5 C at 20 C Accuracy 1 F at 68 F NOTE This thermostat contains electronic circuitry replacing the conventional mechanical anticipator wo M Uy i i My THERMOSTAT INSTALLATION Insert a flat blade screwdriver or a coin 1 8 into the slot located in the bottom center of the thermo stat case and twist 1 4 turn When you feel or hear a click grasp the case from the bottom two cor ners and separate from the subbase as shown in the diagram at the right Some models require more force than others when separating due to the number of terminals on the subbase Swing the thermostat out from the bottom Lift the thermostat up and off the subbase Place the rectangular opening in the subbase over the equipment control wires protruding from the wall and using the subbase as a template mark the location of the two mounting holes exact verti cal mounting is necessary only for appearance Use the supplied anchors and screws for mounting on drywall or plaster drill two 3 16 6mm diame ter holes at the marked locations use a hammer to tap the nylon anchors in flush to the wall surface and fasten subbase using the supplied screws Do not overtighten DSL 100 a AVAVATAUAUAUAUAL AAA
5. limits for a Class B computing device pursuant to Subpart J of Part 15 of FCC rules This page intentionally left blank This page intentionally left blank Model DSL 100 INSTALLER NOTES INSTALLER NOTES 111 123 97041 INSTALLATION INSTRUCTIONS LOCATION To ensure proper operation the thermostat should be mounted on an inside wall in a frequently occupied area of the building In addition its position must be at least 18 46cm from any outside wall and approx imately 5 1 5m above the floor in a location with freely circulating air of an average temperature BE SURE TO AVOID THE FOLLOWING LOCATIONS behind doors or in corners where freely circulating air is unavailable where direct sunlight or radiant heat from appli ances might affect control operation on an outside wall adjacent to or in line with conditioned air dis charge grilles stairwells or outside doors where its operation may be affected by steam or water pipes or warm air stacks in an adjacent parti tion space or by an unheated uncooled area behind the thermostat where its operation will be affected by the supply air of an adjacent unit near sources of electrical interference such as arc ing relay contacts SPECIFICATIONS Rated Voltage 20 30 VAC 24 nominal Rated 0 08 Amps to 1 5 Amps continuous Current per output with surges to 4 Amps Max Control Heating 38 to 88 F in 1 Steps Range 5 to 30 C in 1 Steps Thermostat Me
Download Pdf Manuals
Related Search
Related Contents
Step 1 Lenovo IdeaPad U310 Manuel français intranet manual Cisco Nexus 5548UP Lavabiancheria Istruzioni per l`uso JSK42 取扱説明書【PDF】 GAMMA - MILO - Motorisation de portail Adyx, Diagral by Adyx Copyright © All rights reserved.
Failed to retrieve file