Home
Operating Instructions - Elma Ultrasonics New Zealand
Contents
1. Keep the water from entering the ventilation slits in the unit covers Fill in the water slowly Ensure that only the required quantity is filled see section 3 5 Technical details pressure tank capacity Any water surplus must be wiped off Close the screw cap by hand If any water has entered the unit let it dry over a period of several hours The allowed filling quantity of the tank cannot be exceeded due to the integrated overflow If the unit has released a minimum filling level alarm LED min water the safety temperature switch illustration 3 9 1 2 must be reset Filling of the unit 5 2 Pump guarantees optimum filling level A NOTE A NOTE A NOTE Automatic filling with pump optional The pump automatically fills the tank with the optimum quantity of water There are no idle phases due to required cooling down phases as when filled by hand As soon as the water level in the tank goes below a certain level the pump automatically refills the tank up to the optimum level During the filling process the LED pump min is active illustration 3 10 As soon as the maximum filling level in the tank is reached the LED pump max illustration 3 10 turns on Risk of damage caused by water in case of loosened water tube Shut down the water supply after operation or when the unit is unattended Risk of damage to the pump due to running dry The water supply valve
2. If the switch is turned to on the steam release at the outlet can be activated with pressing additional key Product description 3 9 Description safety temperature switch The safety temperature switch is released when the minimum filling level min water in the pressure tank is reached it automatically cuts off the heating of the Elmasteam There is an additional visual signal LED min water and an acoustic alert signal When the unit has been refilled the safety temperature limit must be reset by hand in order to allow further operation of the unit To reset the malfunction indication by hand unscrew the cover anti clockwise see illustration 3 9 1 and press the green button of the safety temperature switch see illustration 3 9 2 Caution A reset of the safety temperature limit without refilling of the pressure tank may destroy the heating Bild 3 9 1 safety temperature switch with cover Bild 3 9 2 green button to reset the alarm Product description 3 10 ready heating min water pump max pump min Description LED operating display min water pump max pump min llustration 3 10 LED Operating display here model with pump turns on as soon as the pressure tank operating pressure is reached and the unit is ready for operation is on during heating up of the unit turns on as soon as the minimum filling level in the pressure tank is reached and the t
3. Operating Instructions TECHSPAN Elmasteam ES 3000 ES 5000 CAUTION Read and observe the operating instructions before you operate the unit TECHSPANGROUP Australia Tel 1 800 148 791 New Zealand Tel 0800 603 603 www techspanonline com Content 1 General sci nek E E ee ede leanne Goeeeoeeesies 3 2 Important safety warnings cccccceeeeeeeecneeeeteeeeeeeereees 3 2 1 Description of safety warnings on the unit 5 3 Product deSCription ccc ec eeeeeeeeeeeeeeeeeteeeeeeeeeeeteeeeeeees 7 3 1 Delivered equipment and accessories cccccceee 7 3 1 1 Elmasteam 3000 eccccceccceeeeeeeeeeeeeeeeeeeees 7 3 1 2 Elmasteam 5000 cccecceeccceeeeeeeeeeeeeeeeeeeees 7 3 2 SCE COMMON GY e2etten vests tt aE a aa 7 CES S Ataoi o lalale EEEE A AAT T 7 3 4 Safety deviceS s nsssissrrrssrrirriiinirederreuiuuneseseecereaseesss 8 3 5 Fechnicaldetail Srni iaenn arrit ea aaa 8 3 6 Description elements top VieW cceccceseeeeeeeeeees 9 3 7 Description elements front VieW 0 ceeeeee 10 3 8 Description function switch sesseesseessernrrenrrerrrene 11 3 9 Description safety temperature switch 12 3 10 Description LED operating display 0 0008 13 3 11 Description elements back vVieW ceeeeeees 14 3 12 Operation of the fixed nozzle cceeeeeeeees 15 3 13 Operation of the flexib
4. The unit must be opened by authorized specialized personnel only Pull the mains plug before opening the unit Do not operate the unit if a mains cable or important components of the unit e g safety devices steam nozzle are damaged If you use an extension cord ensure that plug and coupling are waterproof Caution an unsuitable extension cord may be dangerous Do not operate the Elmasteam with empty water tank as this might cause damage to the unit Operate the unit with water only Steam jet cleaners can produce an uncomfortable noise during operation Use your personal ear protection device when in close proximity to an operating unit Carry out the maintenance works at regular intervals as described in the present Operating Instructions in order to guarantee the correct functioning of the unit and to keep the safety standard see section 7 Repair must be carried out by authorized specialized personnel only Pull the mains plug before opening the unit Always pull the mains plug before you open the unit or carry out any maintenance work High pressure hoses facilities and coupling pieces are important safety components Use high pressure hoses facilities and coupling pieces recommended by the manufacturer only In case of damage or faulty operation please contact your supplier or the manufacturer of the unit Important safety warnings 2 1 Description of safety warnings on the unit Caution When o
5. g ow C g C O E O O OCOC a ee cor CUO TOO CCN E Illustration 6 1 1 Connect the compressed air duct at the correct connection socket Press the blue flexible coupling of the compressed air connection see illustration 6 1 2 A and pull the compressed air duct B out of the connection socket at the same time Handling during operation CNY Illustration 6 1 2 Remove the compressed air duct 6 4 Operation with wet steam optionally ES 5000 The humidity of the wet steam can be controlled by the two turning knobs at the unit front see illustration 6 4 Wet steam is available in one steam outlet e with combination of fixed nozzle flexible hand piece gt fixed nozzle e with combination of fixed nozzle fixed nozzle gt left fixed nozzle e with combination of flexible hand piece flexible hand piece gt left hand piece A Control of dry steam portion optional on ES 5000 for the ratio of mixture for wet steam operation B Control of wet steam portion optional on ES 5000 for the ratio of mixture for wet steam operation steam Illustration 6 4 Control of wet steam operation Maintenance care repair 7 Do not open the unit 7 1 Visual inspection Decalcify the unit A CAUTION Preliminary How to proceed Maintenance care repair Maintenance works requiring the opening of the unit are not necessary Read and observe the following instructions
6. 2 point 6 Putting out of action and waste disposal The unit can be taken to metal and electronics recycling stations or returned to the Distributor Contact address TECHSPANGROUP Techspan Australia PO Box 1012 Mascot NSW 1460 Techspan New Zealand PO Box 15262 New Lynn Auckland 1007 Australia Ph 1 800 148 791 Fax 1 800 148 799 New Zealand 64 9 827 6567 Fax 64 9 827 6596 e mail sales techspanonline com Please visit our website for helpful information and descriptions on our large product range www techspanonline com Do you have any queries or suggestions concerning the present unit its operation or the Operating Instructions Please contact us we will be glad to assist Subject to manufacturer s technical and visual modifications Techspan_12 04 TECHSPANGROUP
7. as soon as water starts flowing out see illustration 5 2 2 2 A When the LED pump max at the unit is lighted close the screw cap at the pressure tank Risk of damage to the pump due to dry running Ensure that the water tank is always sufficiently filled Filling of the unit Illustration 5 2 2 2 Ball valve for the ventilation of the system Handling during operation A CAUTION A CAUTION Preconditions Tank must be filled Switch the unit in position standby Green indicator lamp ready Switch the unit on Switch the unit in position standby Holding the work piece Suitability of cleaning items Distance to steam outlet Handling during operation Risk of scalding by hot steam Unauthorized third persons must not keep within reach of the steam jet during operation of the unit Ensure your own safety Be careful when the steam outlet is activated Avoid hazardous situations caused by unintended activation of the steam outlet Switch the unit into stand by mode during operating breaks Risk of scalding due to hot surfaces The unit surface the steam outlet nozzle and the drain valve heat up considerably during operation Put the unit into operation as described in section 4 Make sure before start up that the tank is filled Otherwise fill the tank as described in section 5 Switch on the Elmasteam by turning the function swit
8. before carrying out any maintenance works Monthly maintenance works Check the mains cable and all electric connections for damage regularly For reasons of safety replace all damaged cables and connections before any further operation If the unit is operated with calciferous city water tap water there is a risk of calcification of various unit components To prevent damages from the unit caused by calcification rinse the pressure tank at least once per month If the unit is continuously operated with tap water a certain amount of lime will collect in the pressure tank depending on the water hardness The lime will sit on the walls of the pressure tank and on the heating element Lime particles that come loose may choke unit components such as valves and nozzles The manufacturer cannot be held liable for any damages on the unit caused by maintenance carried out improperly or not at all Risk of causticization Do not fill decalcifyer or other chemicals into the unit For decalcification use water only The unit must be cooled down before decalcification can be carried out depressurize the unit The pressure tank should be filled up to maximum level 1 Unscrew the blind screw at the ball valve with a fork wrench by turning it anti clockwise 2 Screw the maintenance tube included in delivery to the ball valve illustration 3 11 F 3 Switch the unit on and let it heat up 4 Observe the pressure increase on
9. must be ready for use at any time and remain with the unit in case of resale We reserve the right to carry out technical modifications on the unit due to advanced development The copyright remains with the editor These Operating Instructions are not automatically revised For the latest revised issue please contact the manufacturer and editor of these Operating Instructions The manufacturer s contact address is indicated on the last page of the Operating Instructions Important safety warnings Read carefully before initial operation Use the Elmasteam steam jet cleaner according to the Operating Instructions In case of improper use the manufacturer cannot be held responsible for the safety of the operating personnel and the correct functioning of the unit The present steam jet cleaner has been designed for the cleaning of items only Do not steam clean living beings Operation by industrial and commercial businesses only After unpacking check the unit for possible transport damages In case of visible damages do not put the unit into operation Contact your supplier and forwarding agent For safety reasons the present unit must be connected to a correctly grounded socket only The technical details indicated on the nameplate must correspond with the available mains connection details in particular those of the mains voltage and current connected value Place the unit at a dry and sufficiently ventilated workplace Keep
10. must remain open during operation Risk of damage to the pump Connect the pump to the city water supply or water from a softening water device only The conductance of softened water must have a minimum value of 15 uSiemens Filling of the unit 5 2 1 Connection the pump at the tap water supply Mounting Ensure that the Elmasteam is switched off The maximum water pressure must not exceed 4 bar 1 Connect the preassembled pump supply hose illustration 5 2 1 A to the water tap you need an additional 72 hose of the required length Fasten this hose between the adapter piece illustration 5 2 1 B and the water tap by means of hose clamps Please ensure secure and safe fastening of the hose Fill the tank with approx 1 litre of water manual filling see section 5 1 This prevents a dry running of the heating during initial operation For initial filling of the Elmasteam via the pump it is recommendable to open the screw cap of the filling duct to release the air from the system As soon as the LED pump max on the unit turns on the screw cap must be closed Open the tap of the water supply Switch the unit on switch position on The unit automatically starts filling and heating the pressure tank The filling process is now automatically controlled When the LED pump max at the unit is lighted close the screw cap at the pressure tank Illustration 5 2 1 Connected connect
11. the unit dry For safety reasons the steam jet unit must be operated by authorized and sufficiently instructed personnel only The unit must not be operated by unauthorized persons or by children During operation the unit cover the steam outlet nozzle and the drain plug heat up considerably Important safety warnings Caution Hot steam Prevention of electrical accidents Filling No chemical additions Noise emission Maintenance and repair Wrong operation may cause a risk of scalding by hot steam Unauthorized third persons must not stay within reach of the steam jet Be careful when operating the unit in order to prevent injuries caused by hot steam Switch the unit into stand by operating mode during operating breaks This prevents unintended activation of the steam outlet Do not open the screw cap of the filling duct of the pressure tank with a pressure exceeding 0 bar If the switch is turned to steam outlet steam is immediately produced at the nozzle or at the hand piece without pressing any additional key For the operation mode steam outlet the hand piece must be fastened safely e g in the hand piece holder Ensure that the released steam does not endanger staff or equipment In order to prevent electrical accidents and damage do not steam clean the unit and do not let any liquid enter the unit In case of any damage on the unit or if the unit has become wet pull the mains plug
12. CE conformity The present Elmasteam steam jet cleaner is in compliance with the CE marking criteria and the following EC directives 2006 95 EG Low voltage directive 2004 108 EG EMC directive The declaration of conformity is available from the manufacturer Functioning In a safety pressure tank filled by hand or automatically the water is heated by means of a powerful heating element up to a temperature of 173 C In the process a steam pressure of approx 8 bar is created The steam can be let out through the nozzle s Optional on ES 5000 Steam and hot water from the pressure tank are mixed The ratio of mixture is variable via control valve Tap water of standard water hardness or distilled water If the unit is used with pump the value of conductance must be at least 15 uS Product description 3 4 3 5 Safety devices The Elmasteam steam jet cleaners are equipped with all required safety devices such as e Safety pressure relief valve e Safety pressure tank closing cap prevents opening of screw cap of filling duct by mistake e Safety temperature control e Electric contacts are protected against splash water e Low voltage 24 V in flexible hand piece Technical details Mains voltage Vac Mains frequency Hz Mains connections Mains impedance max Ohm Power max W Current consumption max A 115 V 230V Required mains fuses A 115 V 230 V Protection grade basic uni
13. ank must be refilled There is also an acoustic alert signal Restart after min water alarm is only possible after resetting the safety temperature limit see illustration 3 9 1 2 at the right bottom of the front side of the unit optional on model with pump turns on as soon as the maximum filling level in the tank is reached via the pump optional on model with pump turns on as soon as the filling level in the tank has reached the minimum level and the pump has been activated Product description 3 11 Al A2 D1 D2 Description elements back view Illustration 3 11 back view here ES 5000 Connection for flexible hand piece optional Flexible hand piece mounted optional Connection for feed of external compressed air supply optional Connection for water supply for pump optional Connection for foot activator of fixed nozzle optional Connection for foot activator of fixed nozzle optional mounted Mains cable Connection flexible hand piece optional Ball valve 1 4 for draining the pressure tank and for maintenance purposes Deairing device optional only on model with pump for the deairing of the suction system for pumping from a tank Deairing is not necessary when the pump is connected to the tap Product description 3 12 50 pressed down 100 pressed down 3 13 steam compressed air Operation of the fixed nozzle The foot activated switch controls the steam ou
14. ch illustration 3 10 to the standby position The unit starts to generate pressure see manometer illustration 3 7 D As soon as the operating pressure 8 bar is reached the green LED lamp ready indicates that the unit is ready for operation Turn the function switch to on position The steam nozzle can now be activated In order to prevent an unintended release of steam switch the unit to stand by operating mode during idle phases Turning the function switch to the on position The steam outlet can be activated now Switch the unit into stand by operating mode during operating breaks This prevents unintended activation of the steam outlet Use the recommended accessories for the safe holding of small items sieve small sieve large or tweezers with plastic coating Check before cleaning if the cleaning item the jewellery piece or the dental surgery equipment is suitable for this kind of cleaning particularly with regard to their thermal and mechanical resistance Keep the cleaning item at least 1 cm from the nozzle when holding it into the steam zone Check the cleaning result at short intervals visual inspection Check sensitive surfaces of cleaned items for possible damage Handling during operation 6 1 Key steam Cleaning of items Follow up drying Key compressed air 6 2 Control via foot activated switch Switch positions 50 pressed down 100 pressed d
15. e observe the following instructions e Place the unit onto a dry even and stable surface Ensure that the unit is sufficiently ventilated e Keep the workplace and the unit housing dry e Do not direct the steam jet or hot water jet onto the unit Temperature 5 C to 40 C No condensation allowed Connect the Elmasteam to a suitable shockproof socket The technical details indicated on the nameplate must correspond with the available mains connection details in particular those of the mains voltage and the current connection value Connection of 230 240 V units ES 5000 in 120 V mains L1 Gerat unit L2 PE Diagram 4 1 Required mains conditions for ES 5000 in 120 V mains Initial operation 4 2 Mounting of fixed nozzle optional Ensure that the Elmasteam is switched off Then proceed as follows Mounting of fixed 1 Open and remove the blind screw anti clockwise on the nozzle front of the unit illustration 4 2 1 by means of a fork wrench wrench size 12 mm Please retain the counter nut with a flat spanner of a fork wrench size 14 mm 2 Position the fixed nozzle precisely rectangular onto the connecting duct illustration 4 2 2 The outlet of the nozzle must point vertically downward 3 Retighten the nut with the fork wrench clockwise Illustration 4 2 2 Correctly mounted fixed nozzle 4 Check if the nut is correctly tightened and if the nozzle is fixed with its outlet pointing ver
16. g can lose its validity in case of unauthorized opening of the unit The manufacturer cannot be held responsible for any damage caused by unauthorized opening of the unit If you need to return the unit to a service point or to the manufacturer please ensure that it is completely empty and is shipped in a suitable and safe packing Maintenance care repair 7 3 Malfunction Unit shows malfunction warning signal tone is activated and min water LED is lighted Pressure does not exceed 8 bar heating LED is lighted Sudden release of steam from the housing see illustration 3 6 C Possibly there is a bang to be heard inside the unit Pressure indication shows a value gt 9 bar On units with pump Pump does not switch off Pump max LED is not lighted after automatic filling process max 30 sec Trouble shooting Possible cause filling level in pressure tank too low screw cap of pressure tank was not sufficiently tightened malfunction of the heating safety valve has been released water supply duct is not opened Remedy refill water in pressure tank carry out Reset at safety temperature limit after filling see section 3 9 tighten the screw cap correctly replace the sealing ring if necessary send the unit to a service point send the unit to a service point check the water supply system it may be necessary to release air from the piping system see section 5 2
17. ion tube for water supply Filling of the unit 5 2 2 How to proceed A NOTE Connection the pump at a water tank The conductance of softened water must have a minimum value of 15 uSiemens If the unit cannot be connected to the tap the pump can also be connected to an external water tank The suction power of the pump is designed to a max water column of 1 m i e an external water tank for the water supply can be arranged at a distance of max 1 meters from the unit Connect the pump supply hose illustration 5 2 2 1 to a suitable and sufficiently filled water supply tank 1 Immerse the tube end into the water supply tank and secure the tube against sliding Fill the pressure tank with approx 1 2 litre of water by hand see section 5 1 This prevents dry running of the heating during initial operation For initial filling of the Elmasteam via the pump it is recommendable to open the screw cap of the filling duct to release the air from the system Open the ball valve for the ventilation of the system see illustration 5 2 2 2 B The piping system must be de aired for each new suction cycle Otherwise there is a risk of damage to the pump Switch the unit on switch position on The unit automatically starts filling and heating up of the pressure tank Air escapes from the ball valve When water starts flowing out of the ball valve the piping system is completely de aired Shut the ball valve
18. le hand piece 0066 15 4 Initial Operation eee cece cece cece cece eeeeeeeeeeeeeeeeeeeeeeeeeees 16 4 1 Placement and ambient conditions 16 4 2 Mounting of fixed nozzle optional 17 Dr UMM G OF CNG IMI d 4 Ae tierra nae ahnass Gone n ates 18 5T Filmg by hand eee tcl dea tae hatte atentat aE 18 5 2 Automatic filling with pump optional 19 5 2 1 Connection the pump at the tap water supply 20 5 2 2 Connection the pump at a water tank 21 6 Handling during operation 0 0 0 0 eeeeeeeeeeeeeeeeeeeeeneaees 23 6 1 Working with the hand piece 24 6 2 Working with the fixed nozzle eeeee 24 6 3 Operation with compressed air optional 25 6 4 Operation with wet steam optionally ES 5000 26 7 Maintenance care repair ceeeeeeeeeeseeetseeseeeneeeeee 27 7 1 Monthly maintenance works eeeeeeeeeeeeee eee eeeeee 27 E2 RO Palif eerren eaa aeae EAEE EAE EREE 28 7 3 Trouble shooting satiate ication dimen Baier ein 29 8 Putting out of action and waste disposal 0 0 30 9 Manufacturer s contact address 2 0 0 0 ceeeceeeeeeeeeeeeeeeeeeeees 30 General A Intended use Check for transport damages Mains connection Placement Operating personnel Caution Hot surfaces General The present Operating Instructions are part of the delivered equipment They
19. odel with 1 fixed nozzle D Pressure manometer Display of steam pressure in the pressure tank bar As soon as a pressure of 8 bar is reached the unit is ready of operation E LED Operating mode display Description see section 3 11 F Support for flexible hand piece optional Safety temperature limit description see section 3 9 Product description 3 8 off steam outlet A Standby steam on Description function switch SCE outlet If the switch is turned to off the unit is switched off completely This switch position is for the release of the residual steam pressure before opening the tank closing screw cap Caution Steam is immediately released from the nozzle without pressing any additional key On the ES 5000 the steam escapes as follows e with combination of fixed nozzle flexible hand piece gt fixed nozzle e with combination of fixed nozzle fixed nozzle gt left fixed nozzle e with combination of flexible hand piece flexible hand piece gt left hand piece For the operation mode steam outlet the hand piece must be fastened safely e g in the hand piece holder Ensure that the released steam does not endanger staff or equipment Recommended operating mode during idle phases This mode prevents unintended activation of the steam release The tank pressure remains the same The unit is ready for operation immediately upon turning the switch to position on
20. own Cleaning of the items Follow up drying Working with the hand piece Observe the safety warnings section 2 Start the steam mode by pressing the key at the hand piece As soon as the key is released the steam outlet at the nozzle is stopped The hand piece heats up lightly during the process The steam outlet remains activated as long as the key is pressed The hand piece heats up slightly during the process Release the key to interrupt the steam outlet Keep the cleaning item at least 1 cm from the nozzle when holding it into the steam zone Check the cleaning result at short intervals Check sensitive surfaces of cleaned items for possible damage If the unit is connected to an external compressed air supply the nozzle can be used for compressed air too The cleaning item can be dried with compressed air Start the compressed air mode by pressing the key at the hand piece As soon as the key is released the compressed air outlet at the nozzle is stopped This function is available only with correct compressed air connection on the back of the unit See section 7 1 1 Working with the fixed nozzle Observe the safety warnings section 2 The steam compressed air outlet at the fixed nozzle is controlled by the foot activated switch There are two switch positions Activates the compressed air at the nozzle Optional Only if the unit is correctly connected to a compressor on the back of the housing Activa
21. perated improperly high pressure jets may be dangerous Do not aim the jet toward persons live electric equipment or the unit itself Do not aim the jet toward yourself or other persons for cleaning of clothing or shoes Caution Do not open the ball valve with heated unit and with an overpressure in the pressure tank exceeding 0 bar observe manometer Exception maintenance works see section 7 Caution Hot surfaces Important safety warnings Note only for units with optional compressed air feed duct The connected compressed air supply must not exceed a pressure of 6 bar Risk of damage to parts inside the unit Note only for units with optional water pump The maximum water pressure must not exceed 4 bar Risk of damage to parts inside the unit Product description 3 1 Product description Delivered equipment and accessories 3 1 1 Elmasteam 3000 e basic unit with a tank volume of 3 litres e fixed nozzle or flexible hand piece both optional e compressed air connection inlet optional e filling funnel e pincette e maintenance tube M for monthly maintenance 3 1 2 Elmasteam 5000 3 2 3 3 Pressure generation Steam outlet Wet steam Water for steam generation As Elmasteam 3000 but with a tank volume of 5 litres and with 2 optional outlets for fixed nozzle and or flexible hand piece e compressed air connection inlet optional e wet steam optional
22. t Protection grade hand piece Sound pressure level at 8 bar dBA Steam pressure in pressure tank bar Pressure tank volume lit Max filling volume litre Steam temperature at outlet Housing dimensions with feet W x D x H mm Units overall dimensions w hand piece support fixed nozzle W x D x H mm Housing material Weight incl foot activated switch kg Elmasteam 3000 120 or 230 50 60 shockproof plug 1 phase USA grounded NEMA 5 20 plug 0 155 1790 15 5 7 8 20 10 IPX3 IPX4 93 8 3 2 6 approx 160 C 338 x 260 x 296 385 x 445 x 330 stainless steel approx 16 Elmasteam 5000 230 240 50 60 Shockproof plug 1 phase USA grounded NEMA 6 15 plug 0 155 2950 12 8 16 IPX3 IPX4 93 8 5 4 7 approx 160 C 338 x 260 x 391 385 x 445 x 420 stainless steel approx 20 Product description 3 6 Description elements top view Screw cap of pressure tank filling duct for manual filling Collecting rim for water spilled during filling Ventilation openings Handles Product description 3 7 Description elements front view Illustration 3 7 View unit front here ES 5000 A Function switch Description see section 3 8 B Connection socket only on ES 5000 for the optional connection of a fixed nozzle on model with 2 fixed nozzles C Connection socket for the connection of the fixed nozzle on ES 3000 ES 5000 on m
23. tes steam at the nozzle Keep the cleaning item at least 1 cm from the nozzle when holding it into the steam zone Check the cleaning result at short intervals visual inspection Check sensitive surfaces of cleaned items for possible damage If the unit is connected to an external compressed air supply the nozzle can be used for compressed air too The cleaning item can be dried with compressed air Handling during operation 6 3 Connection A NOTE Connect the compressed air duct Remove the compressed air duct Operation with compressed air optional After the cleaning of the item there is a residual humidity on the material which can easily be dried by means of compressed air The units are fitted with to norm connection sockets for compressed air at the back optional connection see illustration 3 11 1 B and D lf a compressor is available the unit can be connected to the compressed air system The Elmasteam can now be switched over between steam and compressed air at the hand piece or by foot activator For this a suitable Teflon tube diameter 6 mm is required The unit must be connected to a compressed air supply system at max 6 bar Keep the compressed air free of dirt particles Push a suitable compressed air duct into the connection socket as far as it will go see illustration 6 1 1 The connection coupling inside the compressed air connection socket automatically fixes the duct
24. the manometer As soon as a pressure of 3 bar is reached turn the function switch to off 5 Direct the free end of the maintenance tube into a bucket filled half with water Maintenance care repair 7 2 A CAUTION A CAUTION A CAUTION A CAUTION Hot tube Risk of scalding Hot water Risk of scalding Wear gloves when handling the tube 6 Direct the tube into the bucket and slowly open the ball valve the remaining water from the tank is swept through the tube together with the lime 7 Rinse the pressure tank again with 5 10 litres of water 8 As soon as the tank is completely empty close the ball valve and remove the maintenance tube 9 Retighten the screw at the ball valve with the fork wrench by turning it clockwise Repair Should any repair works be necessary please contact your supplier or the manufacturer of the unit Repair works must be carried out by specialized personnel only Risk of electrocution by live parts in the unit Separate the unit from the mains for all repair works Risk of scalding due to released steam Do not open the screw cap at the filling duct with a pressure above 0 bar Do not dismount pressure carrying parts from the unit with a pressure above 0 bar Let the unit cool down before opening Risk of scalding due to hot surfaces Let the unit cool down before opening Use original spare parts only The CE markin
25. tically downward Illustration 4 2 1 Connection with blind screw 2 Mounted fixed nozzle Illustration 4 Filling of the unit 5 1 Let heated unit cool down A CAUTION How to proceed Open the screw cap Insert funnel A CAUTION Filling of pressure tank Close the screw cap Safety temperature limit Filling of the unit Filling by hand For initial filling and for refilling after consumption of the pressure tank water use the filling funnel to fill tap water or distilled water Risk of scalding by hot steam 1 Let the unit cool down before opening Do not open above 0 bar pressure 2 Turn the function switch to steam outlet Release the remaining steam through the steam nozzle For the operation mode steam outlet the hand piece must be fastened safely e g in the hand piece holder Ensure that the released steam does not endanger staff or equipment 3 Slowly open the screw cap the integrated pressure relief system will release any remaining steam from the pressure tank when the screw cap is opened Switch off the unit switch position off Press down and turn the screw cap from the pressure tank illustration 3 6 A anti clockwise Insert the funnel included in delivery in the filling duct Risk of electrocution due to short circuit in the unit caused by water entering the housing Fill the water carefully avoid overfilling
26. tlet at the fixed nozzle There are 2 switch positions illustration 3 12 activates compressed air optionally activates steam Illustration 3 12 Foot activated switch Operation of the flexible hand piece The nozzle is controlled by means of the two keys on the hand piece key A activates steam key B activates compressed air optionally Illustration 3 13 Flexible hand piece Initial operation 4 4 1 Packing Check for transport damages Placement A A CAUTION Ambient conditions Connect the unit to the mains Initial operation Placement and ambient conditions If possible keep the original packing or dispose to the packing in compliance with the relevant regulations on waste disposal You can also return the packing to the manufacturer freight cost paid by the sender Check the Elmasteam for possible transport damages before initial operation In case of visible damages do not connect the unit to the mains Contact your supplier and forwarding agent immediately Place the unit in a dry and sufficiently ventilated place Keep a clear space of approx 15 cm at the back of the unit The outlet of the safety pressure valve is behind the ventilation openings on the top of the unit Attention When the safety valve is activated steam will be discharged through the ventilation openings for a short period Risk of electrocution In order to prevent electrical accidents pleas