1. O F 1 CONICAL NUT EM LIGHT SPACER CONICAL RING WASHER 065 070mm POOL WALL HOLESAW STEEL 300mm 400mm ACCESSIBLE LOCATION FULLY REMOVE TWO 2 A PARTS FROM 4 POSITION ro Y UPWARDS ASSEMBLE COMPONENTS ON TO CABLE IN ORDER CONICAL WASHER CONICAL NUT FIRMLY TIGHTEN BY HAND ONLY THIS FASTENER LOCATED AT TOP FIRMLY TIGHTEN VINYL LINING FASTENERS INSTALLED MANUALLY ONLY CUT 8 REMOVE VINYL INSIDE CLAMP RING REMOVE COMPONENTS FROM NICHE SEALING GLAND CONDUIT GLAND WASHER TAKE OFF PULL CABLE THROUGH CONDUIT TAKE OFF ASSEMBLE CABLE GLAND COMPONENTS IN CORRECT ORDER SEALING 11 TIGHTEN CONDUIT TAKE OFF TO SEAL CABLE WITHIN COIL CABLE ANTI CLOCKWISE OPTIONAL CONDUIT EM LIGHT REMOVAL MODEL HOLDDOWN BUTTON WITH 4 FLAT BLADE N amp RELEASE EM LIGHT FROM NICHE EM LIGHT ASSEMBLY i MODEL EMV MINIMUM 700mm CABLE INSIDE CABLE ANTI CLOCKWISE INSERT EM LIGHT INTO NICHE CLICK CONNECTIONS HOW CONNECT SINGLE EM LIGHT TO G PO 25VA TRANSFORMER POOL LIGHT CONNECTIONS HOW TO CONNECT MULTIPLE EM LIGHTS 4 50VA TRANSFORMER POOL LIGHT POOL LIGHT 19
2. cable must remain stored within the Niche to ensure the light can be accessed above the waterline Maximum cable within niche 800mm The EM series light can be mounted at any angle provided the installation conforms to the above items CLEANING Only use warm water and a soft brush or cloth to clean EM series lights DO NOT use detergents or spirits as this can damage the light and void your warranty USE Do not operate light unless completely submerged in water Operating the light for at least 15 minutes every week is advised all year round EM series lights are designed for continuous 24 7 operation EM series lights are suited for both domestic and commercial installations WARNING The EM series light must only be powered by the supplied 12V AC Spa Electrics transformer DO NOT use electronic or switch mode transformers with EM series lights These transformers will damage the light and void your product warranty Pool chemicals amp PH levels Due to the corrosive nature of unbalanced pool chemicals Spa Electrics strongly recommend that your pool water is balanced prior to installing your pool lights or any plastic or stainless steel components and tested weekly to maintain these levels pH levels should be maintained between 7 2 7 6 at all times to ensure the longevity of these components gt Failure to do so can result in chemical damage to the light housing and pool fittings including
3. CONNECTIONS HOW CONNECT MULTIPLE EM LIGHTS TO G PO CONTINUE DAISY CHAIN 50VA UP TO 10A 25VA TRANSFORMER MAX TRANSFORMER POOL LIGHT POOL LIGHT TROUBLESHOOTING MODEL Light flashing Blue continuously Light flashes 2 times Light colours not synchronised Light not operating 1 Light not operating 2 Light not operating 3 Light not operating 4 Light not operating 5 System is in Reset mode Light over heating Power interruptions or lights have been used individually Faulty connection to transformer Mains power not connected Damaged cable Transformer not working Damage caused by high voltage and or incorrect power supply Refer to multi colour operating instructions Check light is fully submerged Check vents are not obscured Reset lights refer to multi colour operating instructions Ensure cable correctly connected to transformer terminals as per instructions Check transformer is plugged in to GPO and switched on Replace cable Check fuses amp test transformer using multimeter under load ie 20W 12V Return product to Spa Electrics for repair If these issues cannot be resolved with the above recommended actions please contact your distributor or Spa Electrics YOUR INSTALLATION PLEASE RECORD THE DETAILS OF YOUR INSTALLATION FOR FUTURE REFERENCE DATE OF PURCHASE YOUR E
4. stainless steel components gt Please note Lights or components found to have excessive chemical damage will not be covered under our manufacturer s warranty policy This light contains no user serviceable parts opening the light will void the product warranty TOOLS REQUIRED MODEL gt 65mm 70mm Saw gt Silicon caulking gun gt Adjustable spanner shifter gt Phillios nead No 2 screw driver gt Box cutter knife gt Flat blade screwdriver for EM light removal IMPORTANT NOTE The use of power tools such as 240v and cordless drills during installation is not recommended as these devices can cause faults and damage to light components Only use a powered in Step 1 Page 8 when preparing the pool wall for light installation All other installation steps should be carried out with manual tools only PRODUCT SUPPORT AND INFORMATION Phone 61 3 9793 2299 business hours Email info spaelectrics com au SALES enquiries Email tech spaelectrics com au TECHNICAL support enquiries Web www spaelectrics com au INCLUDED PARTS MODEL 25VA SINGLE OPERATION INSTALLATION MANUAL MANUAL Multi Colour Only WARRANTY 1x INCLUDED PARTS MODEL 50VA DUAL KIT OPERATION INSTALLATION MANUAL MANUAL Multi Colour Only WARRANTY 1x FINISHED INSTALLATION MODEL EMV STEEL VINYL CONDUIT WALL NICHE TAKE OFF
5. INSTALLATION amp OWNER S MANUAL ULTRA COMPACT NICHE LIGHT FOR VINYL POOLS STORE THIS MANUAL IN A SAFE ato PLACE FOR FUTURE REFERENCE 5 SERIES CONTENTS READ THIS FIRST TOOLS REQUIRED PRODUCT SUPPORT AND INFORMATION INCLUDED PARTS 25VA SINGLE KIT INCLUDED PARTS 50VA DUAL KIT FINISHED INSTALLATION DIAGRAM ASSEMBLY STEPS 1 14 EM LIGHT REMOVAL FROM NICHE EM LIGHT ASSEMBLY TO NICHE CONNECTIONS TROUBLESHOOTING 15 16 18 21 READ THIS FIRST This booklet contains important information about the correct installation handling of EM series lights Please read this booklet carefully before commencing installation to familiarise yourself with the included parts accessories and correct installation procedures BEFORE YOU START Supplied cable should not be modified 20m cable is supplied as standard 30m amp 50m cable lengths are available to order from Spa Electrics or your distributor Ensure that the lighting system is installed by a suitably qualified persons e g registered pool builder and or qualified electrician in accordance with AS NZS 3000 2007 standards For safe and proper installation ensure that only those parts supplied with the system are used Maximum installation depth for EM Series lights is 400mm All lights should be mounted in a location that is easily accessible without the need for entering or lowering the pool water No less than 700
6. M SERIES LIGHT S WAS SUPPLIED BY DATE OF INSTALLATION POOL BUILDER EM SERIES LIGHT S INSTALLED BY FULL PLEASE STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE SH www spaelectrics com au COPYRIGAT 2012 SPA ELECTRICS PTY LTD ALL RIGHTS RESERVED 20121001

Download Pdf Manuals

image

Related Search

Related Contents

IOCOM visimeet Help  Targus CVR211  1 Av. Portugal, 1032 – Jd. São Luiz – CEP: 14025  dspblok™ 21469 User Manual - Danville Signal Processing, Inc.  Extrait français du manuel de Nikon  USB Sync Board  Error al querer dar de alta un proveedor Antici02  MONICOVIEW II USER MANUAL  AugenschutzArtiluxGeba.qxd 15.02.2006 10:57 Uhr Seite 1  User manual - Snooper Services  