Home

Remote Monitor PTE0700 User Manual PTE0700 V2 Series Remote

image

Contents

1. Table 3 Relay Connections NOTE e The relay contacts are rated at 30V 1A lt 500mA recommended They MUST NOT be used to switch 240Vac e The Relay is fail safe on the PTE702 only This means that in the alarmed condition the C and NC terminals are shorted 1 The Remote Monitor will need to be opened for this feature to be used When not using this feature the unit should remain closed to protect it from the elements 14 02 07 Page 14 of 18 User Manual for Pakton Electric Fence Remote Monitor Series 0 5V Analog Output PTE0700 Only The 0 5V Analogue Output is from terminals V and GND The minimum suggested load resistance on the 0 5V output is 1k The 0 5V analogue output voltage linearly represents the fence voltage ranging from 0 10kV ie Fence Voltage Analogue Output Voltage x 2000 Note The monitor has software filtering which is intended to give the average output over the last 4 pulses 4 20mA Analog Output The monitor current loop output terminal is a current sink or passive transmitter Wire the output so that current flows from positive supply 5 12V through the input of the 4 20mA receiver equipment and then to terminal The current range of 4 20mA will linearly represent a fence voltage range of 0 10kV e Fence Voltage 0 625 x Loop Current 2 5 Take care to read the instructions for the receiving analog input device RS232 Output The RS232 Output is available in
2. trimmer fully anticlockwise e Switch on the electric fence and ensure that it is operating in the expected range e Switch on the Electric Fence Monitor by supplying it with twelve volts If the Electric Fence Monitor was already switched on it needs to be reset by switching off disconnecting the twelve volts supply and switching back on e The Electric Fence Monitor has now automatically set the Low Fence Voltage Alarm Set Point and is now monitoring the Electric Fence You can test its operation by deliberately placing a short on your electric fence the Electric Fence Monitor will raise an alarm e It is recommended that Automatic set point NOT be used for security purposes If the fence starts with a medium voltage due to a fault for example the monitor may perceive that the fence is OK when it is not Low Fence Voltage Set Point Calibration Manual set point e Turn the Volts trimmer fully anticlockwise and then advance it clockwise slightly If you do not advance the trimmer the Electric Fence Monitor will think that it is to automatically calibrate e Switch on the electric fence and ensure that it is operating in the expected range 14 02 07 Page 12 of 18 User Manual for Pakton Electric Fence Remote Monitor Series Switch on the Electric Fence Monitor by supplying it with twelve volts The Green Pulse LED should be flashing indicating a working fence The Low Fence Voltage Alarm Set Point is very low at pr
3. Alarms failing fence by setting a failsafe relay Y Current output 4 20mA proportional to 0 10kV input Y Voltage output 0 5V proportional to 0 10kV input Y Simple RS 232 Data Output viv SCADA friendly RS 232 Data Output Y Hardware IP65 weather proof wall mountable enclosure V ILLL 12V DC Powered V LLJ Adjustment Low Fence Voltage alarm set point or automatic self y setting Adjustable delay from Low Fence Voltage to firing p y y alarm Other Features Very low current consumption V oa ee 10kV Opto Isolation from fence inputs Ae lee a a ES Expansion socket for optional LCD Display V ILLL Connects directly to 12V 2W solar panel to charge y battery Table 1 Model Features 14 02 07 Page 6 of 18 User Manual for Pakton Electric Fence Remote Monitor Series Explanation of some terms used in this section Low Fence Voltage Alarm set point is the fence voltage above which the Electric Fence Monitor will show a working fence and below which the Electric Fence Monitor will show a failing fence The PTEO700 series Electric Fence Monitors allow you to manually adjust this set point or alternatively they can be set to automatically adjust this set point When automatically adjusting it also follows the fence s performance If for example the fence were operating at 7kV when the Electric Fence Monitor is switched on it would set its Low Fence Voltage Alarm
4. cable to the expansion header on the PTEO700 PCB It is secured to the PCB via 4 standoffs provided The display will show the low voltage setpoint and the actual fence voltage It also displays a battery symbol when the supply voltage falls below a satisfactory level Note that the LCD board must be removed to adjust the Low Voltage and Delay set point trimmers Figure 5 PAE036 LCD Expansion PCB 14 02 07 Page 17 of 18 User Manual for Pakton Electric Fence Remote Monitor Series 9 0 Warranty The PTE0700 Electric Fence Remote Monitor Series is covered by a 12 month warranty against defective parts or workmanship If you have any problems return the Monitor to Pakton Technologies Pty Ltd along with your proof of purchase or contact the store of purchase or distributor For assistance If you have any operational problems difficulties etc call our FREE HELP LINE 1800 249 642 within Australia only and not from mobile phones Alternatively phone fax or email your questions or comments to Pakton Phone 07 3888 3793 International 61 7 3888 3793 Fax 07 3888 4330 International 61 7 3888 4330 E mail sales pakton com au Mailing address PO Box 408 Narangba QLD 4504 Australia Street address 16 Ferrier Road NARANGBA Qld 4504 Australia More help is available at the WEB site www pakton com au 14 02 07 Page 18 of 18
5. sccdecie ii e tii 17 14 02 07 Page 4 of 18 User Manual for Pakton Electric Fence Remote Monitor Series 4 0 Description The PTE0700 Electric Fence Monitor Series are low cost electric fence monitors designed primarily for remote monitoring applications While monitoring an electric fence for low voltage conditions they also enable system designers to include electric fence voltages as inputs into remote telemetry or SCADA systems This series consists of four models the PTEO700 701 702 and 703 The features of the various models can be found in the Features section of this document The PTE0700 series can also be customised to meet your own requirements for quantity purchases Suitable Applications for the PTE0700 Series e Rural pastoral stations e Security fences e Vermin control fences e Zoo and sanctuary enclosures 14 02 07 Page 5 of 18 User Manual for Pakton Electric Fence Remote Monitor Series 5 0 Features The various models within this range have the following features lt N ae o o o o N N N N W O D FleElJE Ee Inputs Outputs Aa ajaja Directly connects to 10kV electric fence with high 7 7 y y voltage inputs Shows working fence with Green Pulse LED a EA Shows failing fence with Red Low Voltage LED V AE Alarms failing fence with internal beeper viv v Alarms failing fence by setting a relay viv Y
6. eeeeneaes 12 Delay Calibration automatic and manual low fence voltage alarm Set point 2 ccceseseeeeeeeeeeeeeeeeeeeeeeeeeeees 13 8 0 ELECTRIC FENCE MONITOR OUTPUTS 0 26 ciccs co cevedeessctecsccenssctasdetesededetegectcsteateysutesancdaueeedusaiedaueaatechauereuaiaiees usted 14 MANE OS EA A O O TA 14 EVA AA A A A 14 0 SV Analog Output ii A A ar aa aa Eaa raaa aia 15 4 20mA Analog OU UN A ct a daa sand Sed ces a aae aea cate ch ot seca E duce aaa aaa A o Steel decd 15 R9232 OU UE A a ea aa aaa usa su eee ste aaa dou eda ia AEREA Di 15 Optional Display Board a a a da 17 9 0 WARRAN TVooiociinian aaa aaa ra A an even nau Da Ea 18 14 02 07 Page 2 of 18 2 0 List of Tables Table 1 MOdel Features oia AR eee ein eed 6 Table 2 SPecitICA OASIS ae ee ele 9 Table 3 Relay Connections sieaa kaataa dada ed id il ai di ii 14 Table 4 PTE0700 RS232 Connections ici iii 15 14 02 07 Page 3 of 18 3 0 List of Figures Figure 1 Output Terminal Locations a E 10 Figure 2 Stand Alone Operation saedis eae aces cece ens e aa cesee ea aaa aa a aeaa a E AAE daana A Eada iae aaa daaa 11 Figure 3 Alarm Panel Oper ti n ihoani cece nena aeaaeae aeara eaaa aieia aaaea aan ia aiaiai ainaki 11 Figure 4 Solar Panel Operation cccccceseenneeeeeeeeeeeneeeeeeeeseeeeeeeeesceeseeeseeesenseeeesaeeaeseseeeeesesseeeeseeeseseneeesaaseneesaseonaeeeseaeens 12 Fig re 5 PAE036 LCD Expansion PGB sini ciccccc castes
7. esent because the Volts trimmer is turned almost completely anticlockwise Gradually increase the set point by slowly turning the trimmer clockwise The Low Fence Voltage Alarm Set Point is slowly increasing and will soon rise above your electric fence s voltage When this happens the Green Pulse LED will stop flashing the Red Low LED will flash and after the delay set on the delay trimmer the Fail LED alarm beeper and relay will activate The Low Fence Voltage Set Point is now about the same as your electric fence s voltage and needs to be lowered slightly Do this by turning the Volts trimmer anticlockwise until the Greed Pulse LED begins to flash again If the alarm came on it will self clear in about 30 seconds Delay Calibration automatic and manual low fence voltage alarm set point After setting the Volts trimmer or using automatic setpoint as above The Green Pulse LED should be flashing Switch off the electric fence OR place a short across the live to ground to remove the voltage at the monitor Note the amount of time taken for the Electric Fence Monitor to raise an alarm Turn the Delay trimmer anticlockwise to reduce the delay and clockwise to increase the delay The shorter the delay is the more likely the Electric Fence Monitor is to raise a false alarm because every electric fence will have an occasional low voltage pulse Switching the electric fence back on or removing the short will cancel
8. igo User Manual PTE0700 V2 Series Remote Monitor Pakton Technologies Pty Ltd ABN 66 405 694 842 16 Ferrier Road Narangba Qld 4504 PO Box 408 Narangba QLD 4504 Tel 07 3888 3793 Fax 07 3888 4330 Email sales pakton com au www pakton com au 1 0 Table of Contents 1 0 TABLE OF CONTENTS cui id id a di tate 2 20N MUISTOETABLES 5 A A io 3 3 0 gt LISTO FIGURES A A a eS ed eats a 4 40 DESCRIPTION coartada 5 50 FEATURES oct dawn dv inind Aaa daa daanan aa aaa waved hd Aen aiana 6 Explanation of some terms used in this section 0 ccsececee ee eeee eee eae ea ea eae ea ea aaa saa sa ease ease ease ease saeeaaeaaaaaaaaaeaaaeaeaees 7 6 0 SPECIFICATIONS hiasan ke Ae kane een kane ian ih hee a hii deen When tamed 9 TO INSTALLATION scoot ase otc ood SEG SE SS a ES A a caida Ceara ated 10 Hardware installati nir se ceva secede vevecs ceaceces slautey caiyaveeadddatsveusdevuseddoudecectuwasudeuss dedevesduatucecegeresdduceedee 10 Output Connections a inna ane 10 Stand Alone Operation iii e hn hice eink 11 Alarm Panel Oper aa chee cst each canted a a cans het eid aii eee 11 Solar Panel Operation sida a anal a eae ei ia ee Ried aes 12 Low Fence Voltage Set Point Calibration Automatic Set poOint ccccesceeceeeeeeeeeeeee cece eeeeeeaeeeeeeeseseeeeeeeeeeeeeaes 12 Low Fence Voltage Set Point Calibration Manual Set POint 2 ccccecsseecceeeeeeeeeeeee cece seen ee eeeeeeeeeeseseeaeeee
9. le with Low impedance energisers that meet AS3350 2 76 or IEC60335 2 76 Max 4 20mA loop excitation Supply Voltage 0 7V voltage Accuracy 5 design target Drift less then 1 over temperature range Temperature range 5 to 50 C Table 2 Specifications 14 02 07 Page 9 of 18 User Manual for Pakton Electric Fence Remote Monitor Series 7 0 Installation Hardware installation e Remove the 4 screws holding the top cover in place e Secure the PTEO700 to the wall or mounting device using the 4 mounting holes that will be hidden after the lid is replaced e Thread the 12 volt supply and any output leads into the Electric Fence Monitor enclosure through the cable gland on the side be sure to tighten it to stop water or ants from entering e Attach a suitable insulated cable from the Electric Fence Monitor s red input binding post to the electric fence and from the Electric Fence Monitor s green input binding post to a good earth connection If possible it is best to connect to the same earth that your energiser is using Output Connections The Electric Fence Monitor s Output Connections are visible on the bottom edge of the circuit board and consist of a row of pluggable screw terminals In Figure 1 the screw terminals adjustment trimmers and LED s can be seen They will be referred to in the remainder of this document Voltage and Delay adjustment trimmers Expansion header for optional LCD Output te
10. rminals along Figure 1 Output Terminal Locations bottom edge of PCB 14 02 07 Page 10 of 18 User Manual for Pakton Electric Fence Remote Monitor Series The cables shown should enter the enclosure of the Electric Fence Monitor through the cable gland on the side The connections to the electric fence are not shown in Figure 1 because those cables are terminated at the binding posts outside the Electric Fence Monitor s enclosure For security applications the Electric Fence Monitor can be configured for either Stand Alone or Alarm Panel Operation Stand Alone Operation In Stand Alone Operation the relay outputs can be used to switch a siren on when an alarm condition is raised Figure 2 Stand Alone Operation Alarm Panel Operation In Alarm Panel Operation the relay outputs are connected to the alarm panel See the documentation supplied with the Alarm Panel Figure 3 Alarm Panel Operation 14 02 07 Page 11 of 18 User Manual for Pakton Electric Fence Remote Monitor Series Solar Panel Operation The PTE700 series monitors now have built in circuitry to charge a 12V lead acid battery either sealed or a wet cell from a solar panel Only a 12V solar panel should be used and its output power must not exceed 2W 12 volt 2 watt Solar Panel 12V lead acid battery sealed or wet cell Figure 4 Solar Panel Operation Low Fence Voltage Set Point Calibration Automatic set point e Turn the Volts
11. set point at about 6kV As days go by grass might build up on the electric fence lowering the voltage on the fence or a dry spell might slowly increase the voltage on the fence The Electric Fence Monitor sees the gradual change and adjusts its set point accordingly If however the fence voltage drops more quickly the Electric Fence Monitor will raise an alarm False alarms are less likely to be raised if the Electric Fence Monitor is allowed to automatically adjust its set point Another advantage of using auto adjustment is that the Monitor will also alarm on a quickly rising voltage Adjustable Delay from Low Fence Voltage to firing alarm is the adjustable amount of time the Electric Fence Monitor waits after the fence fails before it raises an alarm For example If the delay is set to six seconds and the fence voltage goes low for only three seconds no alarm is raised The alarm would only be raised if the fence voltage stayed below the Low Fence Voltage Alarm set point for more than six seconds Alarms failing fence with internal beeper means that a small siren contained within the Electric Fence Monitor will sound when the fence voltage goes below the Low Fence Voltage Alarm Set Point Alarms failing fence by setting relay there is one relay inside the Electric Fence Monitor with three terminals discussed fully in Section 0 0 Relay Output below 12vDC powered means that the Electric Fence Monitor is powered by any nominal twel
12. the alarm after about 30 seconds the Green Pulse LED should begin to flash again 14 02 07 Page 13 of 18 User Manual for Pakton Electric Fence Remote Monitor Series 8 0 Electric Fence Monitor Outputs LED Visual Display The Electric Fence Monitor status can be visually inspected via the three provided LEDs The Pulse Green LED will pulse green for each input pulse which exceeds the setting of the Volts trimmer If the input voltage is below the setting the Low centre RED LED will pulse on If the voltage is low or off for a time as set by the delay trim the Alarm LED will light Note that the PTE0702 has a fail safe output In this case the Alarm LED is green The PTE0702 will show a green Alarm LED when the fence voltage is good and it will go out when the voltage is low Relay Output The Electric Fence Monitor Relay has three terminals These three terminals are Common C Normally Closed NC and Normally Open NO When the fence is operating correctly and when there is no power supply for the Electric Fence Monitor the C and NC terminals are shorted and the NO terminal is not connected to anything When the fence voltage goes low and the Electric Fence Monitor raises an alarm the relay toggles connecting the C and NO terminals and disconnecting the NC terminal These contact are intended to be connected to external alarm panels inputs sirens or strobes Terminal Function NC Normally Closed NO Normally Open
13. two forms The first is the default RS232 format for the PTE0701 and PTEO702 The second is used with the PTEO703 and is a more SCADA friendly output Other formats may be available on request Pin Function I Tx Transmit Gnd Ground V Rx Receive used for negative biasing the transmit Table 4 PTE0700 RS232 Connections 14 02 07 Page 15 of 18 User Manual for Pakton Electric Fence Remote Monitor Series PTE0701 and PTE0702 The output string is V 5500 CR LF Where 5500 is a representation of the fence voltage and CR is a carriage return and LF is a line feed PTE0703 The receiving equipment should be programmed to expect a 6 character packet STX voltage 4 ASCII CR where STX is binary 2 and CR is a carriage return At turn on the PTEO703 also transmits some diagnostics information see below This can be ignored by the receiver as it is not prefaced by an STX Please note that while the PTE703 transmits 4 significant digits the basic accuracy is only 8 bit 2 digit In the print out below 6117 represents 6 1kV When no pulse is seen for over 4 seconds 0000 is sent Ver 1 42 7 05 03 auto 0000 set 0116 del 0126 0135 14 02 07 Page 16 of 18 User Manual for Pakton Electric Fence Remote Monitor Series Optional Display Board The PTE0700 series monitors now have the provision for an optional LCD display PCB The PAE036 LCD Expansion PCB connects via a 10 way ribbon
14. ve volt supply such as a mains plug pack or battery 10kV opto isolation from fence inputs means that the fence inputs are not electrically connected to the rest of the circuitry Instead they are connected optically This means that all accessories connected to the Electric Fence Monitor and the Electric Fence Monitor itself are protected from excessive voltages on the fence Current output 4 20mA proportional to 0 10kV input means that the Electric Fence Monitor can supply an industry standard analogue signal to other equipment such as SCADA or Telemetry RTU 14 02 07 Page 7 of 18 User Manual for Pakton Electric Fence Remote Monitor Series e Voltage output 0 5V proportional to 0 10kV input as above for voltage analogue inputs e RS232 output means that the data collected by the Electric Fence Monitor can be transmitted to other equipment in RS232 format The serial port found on most computers uses the RS232 format You can easily use a computer to collect save and display this information 14 02 07 Page 8 of 18 User Manual for Pakton Electric Fence Remote Monitor Series 6 0 Specifications Specification Name E Specification Supply voltage 10 18V DC Supply current 6mA 20mA with relay on Solar Panel optional 12V 2W use with 12V lead acid battery Min measurable input voltage 0 3 kV Input voltage measurement Peak to peak Relay output Dry changeover contacts 30V 1A lt 500mA recommended Energiser compatibility Compatib