Home

SAFEGUARD user manual draft ver04 Finalx

image

Contents

1. 1 INTRODUCTION Thank you for choosing PowerShield This PowerShield SAFEGUARD UPS is designed to provide safe and reliable usage with minimal maintenance Before you start please read this manual It contains instructions relating to safety installation operation maintenance and warranty of this UPS Please keep this manual in a safe place for future use 2 SAFETY INSTRUCTION This section contains important safety instructions that should be followed during usage of Power Shield product Changes and modification to any this unit not expressly approved by Power Shield will void the product warranty ATTENTION Electrical Safety Maintenance must be performed by qualified personnel Failure to do so could result in an electric shock Replace battery only with Power Shield supplied battery Although the product may be unplugged from mains hazardous voltage still may be present through the battery High current through conductive materials could cause severe burns Check that the input power cord output receptacles are in good condition n order to maintain compliance with the EMC directive output cords attached to the UPS should not exceed 10 meters in length Total leakage current from connected equipment and the UPS must not exceeded 3 5mA for a pluggable A type UPS CAUTION Battery Safety When replacing the batteries use the same number and type of batteries See www powershield com au D
2. handles 3 Wear rubber gloves and boots LA 4 Do not lay tools or metal parts on top of batteries 5 LIFT the battery out of its 5 Turn off UPS Make sure all indicators are off compartment and disconnect first 6 Turn off mains AG supoly the Red and then the Black wire pp y connecting it to the UPS Replace 7 Disconnect AC input cord from the mains the same type of battery 4 3 Slide the battery compartment cover back to close the battery housing 9 TROUBLE SHOOTING Check Power Shield FAQ web page or phone technical support for an assistance with a problem that cannot be resolved using the trouble shoot table below Problem Probable Cause The UPS will not turn on Battery is disconnected or utility power is Connect the battery and ensure power is not available at the wall outlet available at the wall outlet Ensure that the UPS is turned on Yellow LED is on and 2 beeps UPS is not connected properly to the Connect the UPS according to the every 30 seconds But mains are mains installation guide normal Circuit breaker has tripped Reset circuit breaker on the UPS UPS shutdown after a few UPS output is short circuited possibly Disconnect your computer from the UPS seconds and circuit breaker has due to defective equipment tripped and then reset the breaker Inadequate runtime Battery is not fully charged Charge the unit at least 4 hours Battery is near the end of useful life As a bat
3. d the date purchase of the UPS Be prepared to troubleshoot the problem over the telephone with technical support If unsuccessful the technical support will issue a Returned Material Authorization Number amp Warranty Procedure Document Our technical support personnel will also guide you through the process WARRANTY REGISTRATION VERY IMPORTANT In order to validate your warranty it is essential that you register it Warranties must be registered online Please register your warranty by visiting www powershield com au
4. ile mains power is present and the UPS is ON It will also provide power for a limited time from the internal battery when the mains fail FULL TIME SURGE PROTECTION x3 These outlets do not provide any backup power when mains fail They do however provide continuous protection against surges and the like and are perfect for peripherals that do not need battery backup Status indicators See 7 STATUS INDICATOR AND BEEPER section SIDE VIEW 3 AC input Cord 4 Input circuit breaker 10 Amp 5 RJ45 modem phone network Protection 6 ON OFF Switch 7 USB interface port 5 GETTING STARTED Placement Avoid placing SAFEGUARD in e Direct sunlight e Excessive heat Excessive humidity or in contact with fluids of any type CC ed CONNECT EQUIPMENT amp INITIAL STARTUP Plug the AC input cord into the wall outlet Turn on the UPS by pressing the ON OFF button on the UPS For the best results charge the battery for at least 4 hours before initial use Once UPS is fully charged you may now proceed to connect equipment UPS amp SURGE PROTECTION x3 Only devices that require battery backup such as PCs should be plugged into these outlets FULL TIME SURGE PROTECTION x3 Devices like printers that do not require battery backup should be plugged into these outlets These devices will be protected against surges and spikes CAUTION NEVER connect a laser printer or scanner to
5. nto CD ROM drive and then follow the on screen instructions If there no screen shows when inserting the CD after 1 minute please execute setup exe for initiating installation software 2 Follow the on screen instructions to install the software 3 When your computer restarts the monitoring software will appear as an orange plug icon located in the system tray near the clock 7 STATUS INDICATOR AND BEEPER SAFEGUARD provides status indicator through three LEDs located at side of the product as well as audible beep The indications are shown below STATUS Green LED Yellow LED Red LED Beeper On battery Operation Off 2 beeps every 30 sec Low battery status Flashing Rapid beep Off 1 flashing one second intervals every 1sec On line Overload Solidoa fot Solid on Constant beeping On battery overload Solid on Constant beeping Off Flashing Flashing Bad battery detected 1 flashing Off 1 flashing Constant beep every 1sec every 1sec Internal Fault Solid on Constant beeping Flashing Unit performing Battery test via 1 flashing Solid on software every 1sec 8 BATTERY REPLACEMENT 1 SAFEGUARD has user replaceable batteries Please read following warnings and instruction carefully before TURN the unit over and Remove the screws located on the bottom of the UPS to open the battery proceeding with the battery replacement CONE 1 Remove watches rings or other metal objects 2 Use tools with insulated
6. o not dispose of batteries in a fire The battery may explode Do not open or mutilate the battery Released electrolyte is harmful to the skin and eyes A battery can present a risk of electric shock and high short circuit current The following precaution should be observed before replacing batteries This unit contains no serviceable components other than battery Repairing of the product must only be performed by qualified service personnel PowerShield SAFEGUARD PSG750 User s manual 3 PACKAGE CONTENTS You should have received the following items inside of package PowerShield SAFEGUARD 750VA UPS PowerShield User s Manual Communication USB cable SAFEGUARD Veiwer CD monitoring software Note Before installation please inspect the unit and make sure that no damages have occurred during transit If any damage is found please notify your dealer Please keep the shipping materials in the event the product must be returned to a repair centre for service 4 PRODUCT OVERVIEW SAFEGUARD will protect your telephone system PC and other electronic devices from various power quality issues including power loss This UPS features three LED indicators to display the status of UPS TOPVIEW C des Zs i i Ll A NY SS UPS amp SURGE PROTECTION x3 These outlets will provide power wh
7. tery ages the amount of runtime available will decrease Replace battery 10 Product specification ITEM SPECIFICATION Transfer Time Typical 2 6ms 10ms max Waveform Simulated Sine Wave Battery Mode BATTERY Type amp Number 12V 9AH x 1 Recharge Time 4 hours recover to 90 capacity PROTECTION Surge Protection 468 Joules 11000A PHYSICAL Dimension l 292 x 199 x 91 Foot included DXWXH mm 5 88 Net Weight Kg OPERATION ENVIRONMENT 0 90 RH 0 40 non condensing Noise Level Less than 40dB INTERFACE Supports Windows 98 SE ME NT USB Port 4 x 2000 2003 XP Vista 2008 Humidity 11 Warranty and Service WARRANTY CONDITIONS The standard warranty is two 2 years from the date of purchase Power Shield s standard procedure is to replace the original unit with a factory reconditioned unit Power Shield will ship the replacement unit once the defective unit has been received by the service department or cross ship upon the receipt of a valid credit card number The customer pays for shipping the unit to Power Shield Power Shield pays ground freight transportation costs to ship the replacement to the customer within Australia capital cities metro areas only WARRANTY CLAIMS First please follow the troubleshooting procedure described above If you are unable to solve your problem then please call 1300 305 393 You will be required to provide the following details The model number serial number an
8. the UPS amp SURGE PROTECTION outlets This may cause damage to the unit CONNECTING MODEM PHONE NETWORK Connect a single modem phone network line into surge protected IN connector on the back panel of the unit Connect from OUT connector to the computer with telephone line cable CONNECTING USB COMMUNICATION CABLE To allow for unattended OS shutdown start up and status montoring connect the USB communication cable at one end to the UPS and the other end to the PC COLD START FUNCTION When the UPS is OFF and there is no utility power it is still possible to cold start the UPS to power the loads providing your battery has sufficient charge WALL MOUNT of UPS SAFEGUARD can be mounted to a wall surface Use template provided on your product box flaps as a template to position the mounting fastener not supplied Wall mount this product as follows 1 Cutthe template from your product box and hold the cardboard template against the wall in the desired location 2 Use thumbtack or tape to secure the template against the wall Use pin to puncture the centre of each circle to mark the wall 3 Install the mounting fastener at marked location Leave the head of both fasteners 8mm out from the wall The fastener must be able to support 7 0kg 4 Mounting the unit by positioning the keyhole slots over the mounting fastener heads 6 SOFTWARE INSTALLATION 1 Insert the SAFEGUARD Viewer CD i